Loading...
HomeMy WebLinkAboutT12N R3W SEC 25 S2NW4NE4NW4 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program POBox 186O5O 47OVElmore Road Anchorage, Alaska 98518'885V Phone: 904 Fax: (807)343'7997 hnp:6/wv*w.muninqg/nnuita On -Site Wastewater Disposal SystemPermit Permit Number: {}GP261140 Work Type: Septic Upgrade Tax Code Number: 01742203000 Site Legal Address: T12NR3VVSEC 25S2NVV4NE4NVV4 G:2840 Site Mailing Address: 12531TURKGTURN 8T.Anchorage Owner: SMITH |AN&W1|CHELLEM Design Engineer: FORGE ENGINEERING This permit |sfor the construction of: 2 Disposal Field 21 Septic Tank [] Holding Tank [] Privy Effective Date: Expiration Date Lot Size in Sq Ft: Total Bedrooms: 6/10/2026 6/10/2027 217800 Non -Public El Water Well Water Storage All construction shall be|naccordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska VVaetawobar Disposal Regulations (18AAC72)and Drinking Water Regulations (1 8AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On -Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall beeither: o. Opened and Closed onthe same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: Title onthis property was recently transferredwithout the benefit ufoCOGA.ACOSAwill be required to be sought in order to close out this permit. Issued To: FORGE ENGINEERING Date: 8MU/2U26 Issued By: Curtis Townsend 6;0/2026 Development Services Department On -Site Water & Wastewater Section LY1 ;rm q I i 0 0 ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 017-422-03 Phone: 907-343-7904 Property owner(s) Ian & Michelle Smith Day phone (907)317-9001 Mailing address 12531 Turks Turn St, Anchorage, AK 99516 Site address Same Legal description T12N R3W SEC 25 S2NW4NE4NW4 Number of Bedrooms 5 Engineering Firm Forge Engineering Building Permit Number Not Applicable ❑ APPLICATION IS FOR: APPLICATION IS AN: (® all that apply) Disposal Field x❑ Initial ❑ Septic Tank ❑x Upgrade x❑ Holding Tank ❑ Renewal ❑ Privy ❑ Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Permit/Rush Fees: Date of Payment: 13 2 Z u Permit No. 1s (" z 1/�C Waiver Fees: Date of Payment: Waiver No. Distance: May 2025 May 26, 2026 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: T12N R3W SEC 25 S2NW4NE4NW4 – 12531 Turks Turn St Septic system design Dear On-Site Services Engineer: The owner of the above lot intends to build a 5-bedroom home on the property, so we are submitting this permit application for the construction of a new septic system. The existing home was torn down in lieu of the new proposed home. The exact location of the existing septic system is approximated on the plan page. The attached site plan identifies the location of the home as well as the proposed well, septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot has a mild slope of <10% across most of the lot from the east to the west. There is an area right before the road that is >25%. The attached slopes profile shows the presence of this slope will not cause any danger of daylighting effluent from the proposed trench. Contours are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. The alternate site is located more than 6’ away. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261140, Curtis Townsend, 06/10/26 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=50' T12N R3W SEC 25 S2SE4NE4NW4NW4 CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND T12N R3W SEC 25 S2NW4NE4NW4 FEET 0 50 100 5-B D R M H O M E SEPTIC PLAN 5/26/26 10' Utility Esmt 10 ' R O W G A S E A S EM E N T 20 ' CE A E l e c & T el e Es m t EXISTING WELL w/ 100' RADIUS (TYP) TU R K S T U R N S T 1500-GAL SEPTIC TANK 63' LONG X 5' WIDE, 4' EFFECTIVE DEPTH TRENCH APPROX EXISTING SEPTIC LOCATION FIND AND DECOMMISSION ALL PARTS PER UPC TH#1 ALTERNATE SITE CAT III, 25' LONG X 5' WIDE, 0.5' EFFECTIVE DEPTH TRENCH 2COMT FCO CO MT CO Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261140, Curtis Townsend, 06/10/26 T12 R3W SEC 25 S2NW4NE4NW4 TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK DESIGN FACTORS:SYSTEM REQUIREMENTS: 750 GPD PEAK FLOW PERK RATE: 1.7 MIN/IN APPLICATION RATE: 1.2 GPD/SF 5' WIDE TRENCH SYSTEM 1250-GAL SEPTIC TANK BOTTOM OF TRENCH: 11.0' BELOW GRADE FLOW LINE ELEVATION: 7.0' BELOW GRADE 750 GPD / 1.2 GPD/SF / 5' WIDE * 0.5 RED FACTOR [4.0' DEEP] = 62.5 LF TRENCH REQUIRED (63.0 LF SPECIFIED) GEOTEXTILE FABRIC 5/26/26 PROVIDE ADDITIONAL FILL TO ACCOUNT FOR SETTLEMENT 4' 5' 6" 6'-6" Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261140, Curtis Townsend, 06/10/26 E 1180.00 1185.00 1190.00 1195.00 1200.00 1205.00 1210.00 1215.00 1220.00 1180.00 1190.00 1200.00 1210.00 1220.00 0+00.00 0+50.00 0+90.00 1"=10' SLOPE CROSS SECTION SEPTIC TRENCH Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 46 % AN G L E O F E FFL U E N T INF LUE N CE 3:1 MAX SLOPES FEET 0 10 20 6/1/26 T12 R3W SEC 25 S2NW4NE4NW4 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261140, Curtis Townsend, 06/10/26 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 DEPTH (feet) TEST HOLE 1 DATE READING NET TIME (minutes) DEPTH to WATER NET DROP PERCOLATION RATE: (MIN/INCH) (inches)(inches) DATE OF MONITORING DEPTH TO WATER AFTER MONITORING 1.7 4/22/26 1 2 3 4 5 6 SC-SM (CLAYEY SILTY SAND w/ GRAVEL & ROCKS) Professional Engineers Stamp: T12 R3W SEC 25 S2NW4NE4NW4 4/22/26 017-422-03 IAN SMITH 4 8 165:50 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER PERC TEST LOCATION TECHNICIAN: JUSTIN EARLS 10 8 16 NONE 4/29/26 COMMENTS: SITE PLAN 6 0 16 USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED EXCEPT WHERE NOTED. 5/4/26 MOISTURE NOTED AT TIME OF DIGGING?NO OB (SILTY SAND MIXED w/ ORGANICS & OTHER SIMILAR MATERIAL) 4 8 168:40 10 8 16 6 0 16 4 8 169:30 10 8 16 6 0 16 4 8 1610:00 10 8 16 6 0 16 4 8 1610:00 10 4 16 5 12 16 4 8 1610:00 10 4 16 5 12 16 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261140, Curtis Townsend, 06/10/26 30'30' 30' 30'30' 30' 30' 1220 . 012 1 5 . 0 1210 . 0 1205 . 0 1200.0 11 9 5 . 0 1190 . 0 11 8 5 . 0 11 8 0 . 0 1 1 8 1 . 0 1175.0 11 7 0 . 0 116 4 . 0 116 5 . 0 1220.0 1218. 0 1 2 1 5 . 0 121 3 . 0 1207.0 1 2 0 5 . 0 1 2 2 0 . 0 1225 . 0 X 28.1' 6 8 . 3 ' WORK ORDER No:DATE:SCALE: DRAWN: MB CHECKED: ME ZONING: 1"=80'Mar 6,2025 R6 GRID No:FB BOOK/PAGE: SW2840 172/12-13 SURVEY CERTIFICATION: Alaska Remote Imaging has conducted a physical survey of the subject property, the improvements situated thereon are within the property lines as shown. EXCLUSION NOTES: It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the Plat used for this survey. NOTE: Under no circumstances should any data hereon be used for construction or for the establishing of property lines. PREPARED FOR: Ian Smith ASBUILT SURVEY OF: Found Rebar Found BC Mon. Found AL Mon. Robert O. Lumpkin No. 10459 R E GISTEREDPROFESSIO N A L L A N D S URVEYOR S1 2 NW1 4 NE1 4 NW1 4 Section 25 T12N, R3W, S.M. Anchorage, Alaska 1.Bearings and distances are record per referenced plat unless otherwise noted. 2.Not all monumentation for this survey may be shown on this document. 3.Contour data provided by MOA GIS. ALASKA REMOTE IMAGING Surveying Mapping Land Planning LIDAR 6239 B Street, Suite 201, Anchorage, Alaska 99518 (907) 519-0339 survey@alaskaremoteimaging.comIMAGINGSURVEYING DRAFTING S U R V E Y I N G AL A S K A Plat 78-104 Plat 2015-124 Computed SCALE: 1"=30' Electric Pedestal Electric Vault Well Electric Meter Tree Wood Power Pole Mailbox Guy Wire Anchor :R ANCHORAGE AREA BOP' JGH ~,~),j]/ Department of Environmental d~uality , ~ 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME ~'-~//~/-/~..~, ,~//'[/~-~' MAILING ADDRESS /~ -~-~'/'//~//f/~/~ LOCATION ¢/y.~P~'~///~/L//L//~ I: ' ~"/~/~ /~'/~'/~EGAL DESCRIPTION DISTANCE - / '~ NUMBER OF / INSIDE LENGTH --' INSIDE WIDTH LIQUID DEPTH ~ .LIQUID CAPACITY /~,~O GALLONS. SEEPAGE Pit: NUMBER OF PITS / . DIAMETER '~ ORWIDTH /~,, LENGTH/~, DEPTH /~/~C/~', LINING MATERIAL ~'~4~' CRIBSIZE: DIAMETER ~'~'D~E~'P~H__ DISTANCE FROM: WELL TOTAL EFFECTIVE BUILDING FOUNDATION ~'~ ~i NEAREST LOT LINE ~.~Z~ ~¢. ABSORPTION AREA (WALL AREA) ~/~:~ SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE ,/~-/~ZL-//~? 2/~ CONSTRUCTION BUILDING NEAREST iff FOUNDATION //2 iT LOT LINE /~) CESSPOOL NEAREST SEWER LINE OTHER SOURCES APPROVED DEPTH DISTANCE FROM: SEPTIC SEEPAGE TANK /'~¢~ ~), SYSTEM DISAPPROVED DISTANCES: INSTALLED PIPE MATERIAL: LOT SLOPE: REMARKS: Form N~ EQ-031 DIAGRAM OF SYSTEM NAME OIF APPLICANT GREATE:R ANCHORAGE: AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT pERMIT NO, INSTALLATION OF: SEPTIC TANK ~ SEEPAGE PIT_ ,~ , DRAIN FIELD , OTHER FINANCED THROUGH ~ TO BE INSTALLED SM NOTE= THIS PERMIT I~ NOT VALID WITHOUT SOIL FINAL INSPECTION: 24 HOUR NOT~CE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. WELL TO SEPTIC TANK DIAGRAM OF SYSTEM SEEPAge P~T .1 Z~ _~'"/ ] DRAIN FIELD 4 INCH DIAMETER CAST lEON SIPHON PIPES ON ~EPTIC TANK AND SEEPAGE PIT FITTED WITH AIETIGHT REMOVA~3LE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION, OR LICENSED DESIGNER GREATER ANCHORAGE AREA BOROUGH Dep?~ment of Envircnmental Quality,~-~ 3330 "C" Street Anchorage, Alaska 99503 Performed for Sidne.7 Stiver Date performed ~e.!t 31~ 1974 Legal Description:,,~; . ~¥,~. ~0~.75 ..... ~ ~,:er~<t~ 'L:~- o~ }771 ~- o~ ~ ~ ox' . ~ Th~s fom reports:-~Soils Io~ ~ Percolation test Depth Feet 6 - ~2JF Sil~f Sandy Gravel .t0 - //o 11 - Sw WellGraded Sand & Gravel 12¸-- 13- I ' ~as~gro~n~ater encountered? ~,'o If yes, at what depth? .... Reading ' Date GroSs Time Iiet Time Depth to H20' Net Drop · Percolation rte minute, Proposed installation: Seepage Pit ..... Drain Field Depth of Inlet Depth to bottom°of pit or trench CONME~FFS: . f, 7' y ~_2~5~ + ~ ~].~ ~ 125)~ ~950 ~18 = 164 s.f. _ ~ __1~ ) ~~~. , _.,.~-.~ ..... Perfomed By: ~. Certified By.~r~/:/ ~ ., -~