Loading...
HomeMy WebLinkAboutT12N R3W SEC 23 PARCEL 27E Onsite File T12N R3W Sec . 23 Lot 27E #015 - 494 - 09 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181302 PID Number: 015-494-09 Dwelling: ® Single Family (SF) E Duplex (D) [' Multiple (SF and/or D) Project: [' New ® Upgrade Name: HARRY & LOIS DONAHUE FAM. TRUST ABSORPTION FIELD - EXISTING Address ❑ Deep Trench ® Shallow Trench ❑ Bed E Mound 6000 Moose Meadow Lane Circle, Anchorage ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot Ft. Ft. Parcel 27E Fill added above original grade Gravel length Township Range Section Ft. Ft. 12N 3W 23 Gravel width Beds: Number of Lines Distance between lines SEPARATION DISTANCES Ft. Ft. To Septic I Absorption Lift Station Holding Sewer Total absorption area z Number of trenches Dist.between trenches From Tank Field Tank Line Ft -- -- Ft. Well 100'+ NA NA NA NA TANK ® Septic ❑ S.T.E.P. ❑ Holding El Other Manufacturer Capacity Surface Water 100'+ NA NA NA INFILTRATOR 1537 Gal. Material Number of compartments Lot Line 5'+ NA NA NA HDPE 2 NA Foundation 10'+ NA NA NA LIFT STATION 1 Manufacturer Capacity Curtain Drain NA NA NA NA -- -- Gal. I Pump on level at Pump off level at High water alarm at Remarks Existing septic tank decommissioned per code. -- in. -- in. -- in. Pump make and model Electrical Inspections performed by Franklin 2445040117— 1/2HP MOA PIPE MATERIAL House to tank 3034 Tank to 3034 Installer Northern Excavation _ drainfield Drainfield CO/MT 3034 Inspector First Water Consulting Services BENCH MARK (Assumed elevation) 100 ft Inspection S1 1 9/10/18A 9/11/18 Location and description dates: 2" 3`° 4`" Bottom of Siding COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL v1p ....--:\ ..„ OF A/4 I Conditional Approval: Date 0, c7•• •••..,, rle :49TH •• * / • r fij o ° o t g.,•••• CE-MICHAEL N. ANDERSON .....Z r�� 9469 • s Approve. _ i �- =� Date 9'-1 7-0 1kka,iCfESS;O�s.r o��ti�� Inspection Report_9-1-12.doc Permit No. OSP181302 Page: 2 of 2 Municipatity of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744 On—Site Wastewater Disposal System and/or Well Inspection Report Legal Description: T12N R3W SEC 23 PARCEL 27E PID No.: 015-494-09 7 W N t.+ MT PSp1,1PLZ P PRK1�G COs ,S` PREPD• C,I / --- /\ 2 •C CO !� CO \ C t,FCO INSTALLED NEW 1537—GAL A> 6HDPE SEPTIC TANK W/ CO A POST CONNECTED TONEXISTING FIELD. * . N�# h /100' WELL RADIUS A/ , / 1fa /\41. 41, g. ar , fi `l. MT / I A—C=21,3' B—C=30.9' A—D=29.2' B—D=37.6' SCALE' 1' = 30' FCO FCOC01 CO2 NT MT +'�_` er TCO2 �t / < . OF 44; \, \,9914 FINAL GRADE 4 96.82 1 INSULATION ` (C '' � * 4• THi� 94_,2§/ 1 37 GHDPE ALLON N fl4.01 DOSTINC FIELDIA ,1 / # .MICHAEL N. ANDERSON. 90.34 4 No. CE 946 .44: SEPTIC SECTION \ ESS1O ' .k`__-0- V��""""Tr MUNICIPALITY OF ANCHORAGE �a n f On-Site Water&Wastewater Program PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http://www.muni.orgionsite _ r Du partm n 4'�CMORP On-Site Wastewater Disposal System Permit Permit Number: OSP181302 Effective Date: 8/31/2018 Work Type: SepticTank Upgrade Expiration Date: 8/31/2019 Tax Code Number: 01549409000 Site Legal Address: T12N R3W SEC 23 PARCEL 27E G:2638 Site Mailing Address: 6000 MOOSE MEADOW LANE CIR, Anchorage Owner: DONAHUE HARRY & LOIS FAM TRUST Lot Size in Sq Ft: 108900 Design Engineer: ANDERSON CONSTRUCTION & ENGINEERING Total Bedrooms: 4 This permit is for the construction of: ❑ Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Date: q/1 7/46 Issued By: 1 � CoJthU Date: g® $ MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-494-09 Property owner(s) HARRY & LOIS DONAHUE FAM. TRST. Day phone 9074404601 Mailing address 600 UNIVERSITY ST., SEATTLE, WA 98101 Site address 6000 MOOSE MEADOW LANE CIRCLE, ANCHORAGE, AK 99516 Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) T12N R3W SEC 23 PARCEL 27E Lot Size 108900 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field Initial Single Family (SF) I x] (w/wo ADU) Septic Tank Upgrade [] Duplex (D) Holding Tank Renewal n Multiple Dwellings ❑ Privy n (SF and/or D) Private Well n Water Storage n THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Sigrrafure of/property owner or authorized agent) y Permit/Rush Fees: dI6 Waiver Fees: Date of Payment: ?.I 3\Ili Gk lo►° Date of Payment: Receipt Number: o? l Receipt Number: Permit No. ofoeIg 0302- Waiver No. Permit App_9-1-12.doc Michael N. Anderson, P.E. Civil/Structural Engineering and Construction 4661 Natrona Ave. Anchorage, Alaska 99516 Phone 345-3377 Fax 345-1391 August 31,2018 Municipalities of Anchorage Departments of Health and Human Services P.O. Box 196650 Anchorage,Alaska 99519-6650 Fax 249-7847 Re: New Septic Tank Permit Legal: T12N R3W SEC 23 PARCEL 27E The owner has requested we proceed forward to obtain a septic permit to upgrade the aged septic tank on the subject lot. The proposed upgrade will serve the existing 4- bedroom house. The lot and area is served by private water and this system will not impact any of the neighboring properties due to the lot layout. Please contact me if you have any questions. Sincerely, Michael N. Anderson,P.E. DESIGN CRITERIA+ INSTALL 1530—GAL HDPE SEPTIC TANK MAXIMUM DEPTH OF 4' & INSULATE MAINTAIN 10' FROM FOUNDATION & 5' FROM FIELD MAINTAIN 100' FROM WELLS, SURFACE WATER & VERIFY ALL OTHER REQUIRED SEPARATIONS ARE MET. THERE ARE NO WELLS WITHIN 100' OF PROPOSED SEPTIC TANK ' I I r I I MT PN A-1 9,RKING AREP II C•: FS+ co F O ' 's#\ ° DECOMMISSION EXIST. ST. a & INSTALL NEW 1530—GAL HDPE SEPTIC TANK WI ��5� POST TANK COs & �` CONNECT TO EXISTING FIELD. ck \/ /100' WELL RADIUS oro. <s. A.A. MT Septic Design Prepared for .411`16k‘ HARRY & LOIS DONAHUE FAMILY TRUST ‹ .. ) OF AZ/Or T12N R3W SEC 23 PARCEL 27E A �� "" 6000 MOOSE MEADOW LANE CIRCLE, ANCHORAGE, AK . 49 * ,t Michael N. Anderson, P.E. DATE: 8/30/2018 # ![ICHAII N. ANDERSON. a i� No. CE 9489 �w`� / 4601 Natrone Ave. DRAWN: FIRST WATER N " 4 Anchorage, Alaska 99516 , , sslo�°�05' (907)727 8864/FAX: (907)345 1391 SCALE: 1" = 30' �`__41P' MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME MAILING ADDRESS LEGAL DESCRIPTION PHONE [~J NEW qq 5o~ T~, N ~, 5 Vd 5e.c 2,5 s~¼ SE~ SW~ N~ LOCATION I DISTANCE TO: I IO-.5 ~ Manufacturer 1%5o : ~ ~ ~ Manu~acturar ~ = DISTANCE TO: m IAbsorPtion area Inside length Dwelling Foundation Total length of lines Material beneath tile Depth Crib depth Building foundation Driller Sewer line OTHER PIPE MATERIALS SOl L T EST RATING INSTALLER REMARKS Dwelling ,~O Width Material Material Nearestlotline/~/~ t Trench width ~Oinches NO. OF BEDROOMS/_./ No. of compartments Liquid depth PERMIT NO, Liquid capacity in gallons Distance between lines .~. Total effective absorption ar~3~ f~o~ .~,. PERMIT NO. Total effective absorption area Nearest lot line Septic tank Absorption area(s) Distance to lot line PERMIT NO, APPROVED DATE LEGAL 72-013 (Rev. 3/78) Permit Applicant: Location: Legal Description: '~/~; ~3~ ~,~1~,~03~ ~'~j~ Lot Size: Type of Soil Absorption System Is: Trench: _ Drainfield: Seepage Bed: ~ Holding Tank: Maximum Number of Bedrooms: _4 Soil Rating(sq.ft/br) /~O~ ~'~',MUNICIPALITY OF ANCHORAG[~"~, Departmen~ Of Health and Environmenta- Protection 825 n Street, Anchorage, AK. 99501 /~(~ 264-4720 * * * HANDWRITTEN PERMIT * * * ~"~ W~ ON-SITE SEWER PERMIT ~ Mailing Address: ~/4~ ~ /~-~ ~ P3none Number: The Required Size of the Soil Absorption System Is: DEPTH LENGTH GRAVEL DEPTH WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE = [~-~ GALLONS * * Permit applicant has the responsibility to inform this department during the Lnstallation inspections Of any wells adjacent to this property and the number Df residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this department ~ill be subject to prosecution. 4inimum distance between a well and any on-site sewage disposal system is 100 feet Eor a private well or 150 to 200 feet from a public well depending upon the type ~f public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Qther requirements may apply. Specifications and construction diagrams are ~vailable to insure proper installation. * * * PERMIT EXPIRES DECEMBER 31, 1 9 8 3 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the residence is remodeled to include more that 3 bedrooms. Signe~: ~m~ ~~ Issued by: Applicant Date: ~//~/~'~ SWP/024 (1/81) ' PERFORMED FOR: LEGAL. DESCRIPTiON: Sil,/ '//~ JNICIPALITY OF ANCHORAGE ' DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. S~reet, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST 2 4- 5 6 7 8 9 10- 11 12 13 1~- 17- I~- COM,,,ENTS /?':f;' 72-008 (6/79) SLOPE PERCOLATI( TEST SITE PLAN t WAS GROUND WATER ENCOUNTERED? SL O IF YES, AT WHAT ,,, E Reading Date Gross Net Depth to Net Time Time Water Drop ,. h-' ~4 . .'...., . . ..~- . ,,. /Jhi '.'_, ~,L, , /' b'4,'~O ,/U/~?/u. , '~',,_ , 1[' · ,3. "' ' //z,/ , :-,' d, /t..~ ' ' / tl 5 ,,'~x dS:.if., /{.. ',- , +ii,, .~/llq, = ,"~:, '~---- - 5. Y' -' i1.. Obr ~I-,S/Pill. , ~ 2 · PERCOLATION RATE -] "" ," .~ V'~,-: ', *EST ~ ~"*~ .,~.~':~" ~..,. . , ~T. ,', ,., , MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST SOILS LOG PERCOLATION TEST EEREORMED"O* /~0~t~ ~fCheSO~ · ECAL DESCR,.T,O* 5W '/'~ ; 1 2 3 4 5 6 7 8 9- 10- 11 13- 14- 15- 16- 17- 18- 19- 20- COMMENTS rOE wyi ,o w, WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Reading Date Z. 5. PERCOLATION RATE TEST RUN BETWEEN CERTIFIED BY: , ' ' Time /o .'// /D.'Z~/ /0: Z~/''~0 IO,' ~Zl. l~.'&~ lo;z/s- I0.'~ //.' o~ /D ~/~. Net Depth to Time Water ID 12'1/~. , ·/41 , ,/42 /k~i 1%5-- (minutesjinch) ~ , FTAND "~///~-, FT Net Drop ·// ·/2 72-008 (6/79) • Municipality of Anchorage !0;,„:0, On-Site Water and Wastewater Program "di(907) 343-7904 SA E T CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 015-494-09 Expiration Date: l -I 1 —(e 1. GENERAL INFORMATION Complete legal description T12N R3W SEC 23 PARCEL 27E Location (site address) 6000 MOOSE MEADOW LANE CIRCLE,ANCHORAGE,AK Current Property owner(s) HARRY&LOIS DONAHUE FAM.TRUST....Day phone Mailing address 600 UNIVERSITY STREET,SEATTLE,WA 98101 Real Estate Agent Day phone 2. TYPE OF.DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual.Water Storage El Holding Tank El Community Class _Well ❑ Community El Public Water System ❑ Public Sewer El Waiver/Variance request for: Distance: Received by: Date: //17/I' COSA to be release•to the' gineer,unless otherwise requested by the engineer. COSA Fee $ 524 Waiver Fee $ Date of Payment cika./tg Date of Payment Receipt Number Oirir Receipt Number COSA# C35'.Oti$l Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and'from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ANDERSON CONSTRUCTION & ENGINEERING Phone 345-3377 Address 4640 SHOSHONI DRIVE,ANCHORAGE,AK 99516 Engineer's Printed Name MICHAEL N.ANDERSON,PE Date 09/11/2018 • -• • 6. DSD SIGNATURE ySystem #1 Approved for bedrooms. •,•,;i i • System #2 Approved for bedrooms. 'F//// • Disapproved. • : , -• Conditional approval for bedrooms, with the following stipulations: p4.1p4.1I Y OJ: ON_s►rc. WATER WASTAND n 3EW r PROGRA R S ERVIC By: / ° Original Certificate Date: `7 O The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: • COSA Checklist X Nitrate Advisory • Septic System Advisory Arsenic Advisory. Well Flow Advisory Other COSA blue sheet_10-10.12.doc If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: T12N R3W SEC 23 PARCEL 27E Parcel ID: 015-494-09 A. WELL DATA *Per acoustic sounding/reading. Cased to 40'+assumed based on nitrate analysis. Well type Private If A, B, or C provide PWSID# Well Log (Y/N) N Date completed CIRCA 1966 Sanitary seal (Y/N)Y Wires properly protected (Y/N)Y Total depth *175'+ft. Cased to *40' ft. Casing height (above ground) 24+ in. FROM WELL LOG AT INSPECTION Date of test •- 7/612018 Static water level •- ft. 228 ft. Well production g.p.m. 1.7+ g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 mL Nitrate ND mg/L Arsenic: ND ug/L Date of sample: 8/23/2018 Collected by: FIRST WATER CONSULTING B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/HDPE Date installed 9/1012018 Tank size 1537 gal. Number of Compartments 2 Cleanouts (Y/N)Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping NA—NEW TANK Pumper_ C. ABSORPTION FIELD DATA Date installed 813.0/1983 Soil rating (g.p.d./ft2 or ft2/bdrm) 190 System type 5-WIDE TRENCH_ Length 140ft. Width 5 ft. Gravel below pipe 1 ft. Total depth 4.5-6 ft. Eff. absorption area 804 ft2 Monitoring tube Y Depression over field N Date of adequacy test 8/27/18 _ Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 0 in. Water added 600 gal. New depth 0 in. Elapsed Time: 10 min. Final fluid depth 0 in. Absorption rate >= 600 g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in.High water alarm level at in. Datum Cycles tested Meets alarm &circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100'+ _ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ _ Public sewer main 75'+ Public sewer manhole/cleanout 100'+ Sewer/septic service line 25'+ Holding tank 100'+ Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10'+ Property line 10'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ ABSORPTION FIELD ON LOT TO: Property line 10' Building foundation 10'+ Water main 10'+ Water Service line _104Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain _50'+(None Known) Wells on adjacent lots 100'+ F. COMMENTS Vacant system(several years)presoaked per code prior to testing. G. ENGINEER'S CERTIFICATION � OF Az le I certify that I have determined through field inspections and / �• � .7 ri review of Municipal records that the above systems are in ; 49TH ;r . ........... • conformance with MOA COSA guidelines in effect on this date. / �,� "'S'•••• Engineer's Printed Name MICHAEL N.ANDERSON,PE �,;MIC TL61i+tANDERSON ;L dl�•. CE-94,69 •. Date 0911112018 �+r�'sh 41(1)..,•'I,/J �•. o� COSA canary sheet_2-6-15.doc 4 ________ V - - SE VEA - - W LA \ E b 30'ROAD EASEMENT ( RECORDED AT BOOK 247. PAGE 180 N 89 57' 26" E 330.15 ii I • ai N a • § N ' T PRY.INB • 1-SP O O 2 o . 0 zo 2 Q WOOD �IIEII O O OO AME . Ch FRa H BLDG . �OVS i j ��� l',- IA 2 W it' CD LU 0 47.0 V Q I- F- O 0 J -J T O R r.. .. _ .,_-. FENCE „� __ __ "_ .. _ .—__ __ ..—__.« 70'ELECTRIC EASEMENT IN FAVOR OF CHUGACH ELECTRIC N 89 59' E 330.11 NOTES : LEGAL DESCRIPTION : THE SW 1/4 OF THE SE 1/4 OF THE SW 1/4 OF THE NW 1/4 OF SECTION 23, T 12 N , R 3 W, S.M. THIS PARCEL IS AFFECTED BY RECORDED EASEMENTS AS SHOWN ON THE TITLE REPORT PREPARED BY FIRST AMERICAN TITLE ( COMMITMENT NUMBER 0201-3115894), AND ARE SHOWN HEREON . SURVEY CONTROL WAS DETERMINED USING RECORD PLATS 77-189, 82-268, AND 82-46. AS BUILT SURVEY SCALE 1" = 40' Q�QOQQO4 NO CORNERS SET THIS DATE v,Ok ..OF A�g•1p0 O�Q, . `��� suaveroROEREoer I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY ',cp...49 TH (1 t/Q DAR WALDEN @ OF THE FOLLOWING DESCRIBED PROPERTY * OD KELLER WILLIAMS SEE NOTES V-5-407444/---1' ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE Ov ! AfJ'; VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN ,.C._. . ,;-A THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS u • . SHANE A.HOLT .. m O CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS; AND IS 'W., a LS-6914 49 NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES. EXIST OTHER THAN NOTED. 041�ea .•.,. .,.... d o EASEMENTS OF RECORD, OTHER THAN THOSE APPEARING ON THE RECORD PLAT , ARE NOT SHOWN DATED AT ANCHORAGE,ALASKA THIS 12 TH DAY OF VD ,,, es SiOnel 5', NOTE: FENCELINESNTHATTED)MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE SEPTEMBER , 2018 ���OOOo� PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS. HOLT LAND SURVEYING ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE. 9309 GROVER DRIVE ANCHORAGE,AK 99507 14009,FB 189-72,192-27 345-5513