HomeMy WebLinkAboutT12N R3W SEC 25 E2NE4NW4NW4NW4T12N R3W Sec. 25 E2NE4NW4NW4NW4 #017-421-10 Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water & Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number: OSP101059 PID Number: 017-421-10 Name: JOHN MITCHELL Wastewater System: ❑ New ■ Upgrade Address: 7540 UPPER HUFFMAN, ANCHORAGE, AK, 99516 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 269-0413 3 ■ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound ❑ Other LEGAL DESCRIPTION Soil Rating: Total Depth from original grade: 0.6 GPD/Sq. Ft. 10 ( MAX) Ft. Block: Lot: Subdivision: N 330', E2, NE4, NW4, NW4, NW4 Depth to pipe bottom from original grade: 1.95 Gravel depth beneath pipe: (MAX) Ft. 8.05 Ft. Township: 12N Range: 3W Section: 25 Fill added above original grade: Gravel length: SEE DWG. Ft. 50 �. WELL: ❑ New ❑ Upgrade Grovel width: 2.5 Number of lines: Distance between lines: Ft. 1 — Ft. Classification (Private, A,B,C): Cased To:(BEDROCK) Total absorption area: Pipe material: r Ft. G Ft. 805 so. Ft. D 3034/ F-810 Static Water Level: Installer. WILCO CONTRACTORS Date installed: 6/18-19/2010 Driller. N Date Drilled: Ft Yield: Pump Set At: Casing Height Above Ground: GPM Ft. Ft. TANK SEPARATION DISTANCES ■ Septic ❑ Holding ❑ S.T.E.P. ❑ Other* To From Septic Tank Absorption Field Lift Station Holding Tank Public/Private Sewer Lines Manufacturer. ANCHORAGE TANK Capacity in gallons: 1000 Well 100'+ 100'+ — — 25'+ Material: STEEL Number of compartments: 2 Surface Water 100'+ 100'+ - - - LIFT STATION Lot Line 5'+ 10'+ — — — Size in gallons: 1 Manufacturer. Foundation 5'+ 10'+ — — _ "Pump on" level at: "Pump off" at: High water alarm at: Curtain Drain NONE KNOWN Pump Make el: Electrical Inspections performed by: Remarks: BENCH MARK Location and Description: BOTTOM OF WINDOWFRAME, SW CORNER OF HOUSE Assumed Elevation: 100.00 Ft Inspections performed by: GEG, Ltd. Dates: 1st 6/18/2010 ENGINEER'S SEAL Eo�Opp 2nd 6/19/20100 o�� s�4o 3rd Development Q Services Department Approval p * 9 TH,,`*�0 Conditional approval: Date: .............0 .J f A. ness.: Q Q� 'CE -7953 mph �' �� .. !f Reviewed and approved �,���� %:- � Date: !7 4� b 2 ,�• o0 �D�ap �`�i��, (Rev. 4/06) a�4=1 O rofessio� o PERMIT NUMBER: OSP101059 AS -BUILT DRAWING PARCEL 421-10 EXISTING DRAINFIELDS CONNECTED AS RESERVE SITE--' A B C ST1 84.03 45.76 32.88 ST2 89.32 51.57 35.48 DBL1 91.18 53.48 36.37 DBL2 92.13 54.50 36.94 SPL 92.95 55.35 37.31 C01 92.43 55.62 38.63 CO2 93.04 55.13 36.67 MT1 110.28 67.99 37.28 CO3 109.53 66.63 35.26 MT2 154.48 105.72 64.05 C04 1155.341106.721 65.11 EXISTING DRAINFIELDS CONNECTED AS RESERVE SITE--' C01 ITER CO2 CO3 KENNEL - OLD SEPTIC TANKS WERE ABANDONED PER UPC ---NEW 1000 GALLON SEPTIC TANK C SHED TH#1 \ TESTHOLE LOCATIC WAS APPROXIMATI r2 ON DESIGN. NEW DRAINFIELD ii it �, a� ���.� �� Q�� •' s .. ul GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS �..... • • • • • • • • • 3701 E. TUDOR ROAD. SURE 101 • ANCHORAGE, AK 99507 • PHONE (907)337-8179 • FAX (907)338-3248 • WEBSRE: www.9aman ginwring.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: • • • • • •' JOHN MITCHELL 907-269-0413 2 OF 3 J A. arne s.- LEGAL DESCRIPTION: DRAWN BY: 0049 CE -.795 T12N, R3W, SEC 25; N 330', E2, NE4, NW4, NW4, NW4 A.J.G.4 (�I�f 4� �AoG e o dF'rofess'10 o' TYPE OF WORK: DATE: QOOOO��OOoo AS -BUILT DRAWING OF NEW SEPTIC SYSTEM 6/24/2010 (Rev. 01/05) I I I of I I/ EXISTING DOUBLE I CLEANOUTS o C01 ITER CO2 CO3 KENNEL - OLD SEPTIC TANKS WERE ABANDONED PER UPC ---NEW 1000 GALLON SEPTIC TANK C SHED TH#1 \ TESTHOLE LOCATIC WAS APPROXIMATI r2 ON DESIGN. NEW DRAINFIELD ii it �, a� ���.� �� Q�� •' s .. ul GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS �..... • • • • • • • • • 3701 E. TUDOR ROAD. SURE 101 • ANCHORAGE, AK 99507 • PHONE (907)337-8179 • FAX (907)338-3248 • WEBSRE: www.9aman ginwring.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: • • • • • •' JOHN MITCHELL 907-269-0413 2 OF 3 J A. arne s.- LEGAL DESCRIPTION: DRAWN BY: 0049 CE -.795 T12N, R3W, SEC 25; N 330', E2, NE4, NW4, NW4, NW4 A.J.G.4 (�I�f 4� �AoG e o dF'rofess'10 o' TYPE OF WORK: DATE: QOOOO��OOoo AS -BUILT DRAWING OF NEW SEPTIC SYSTEM 6/24/2010 (Rev. 01/05) PERMIT NUMBER: AS—BUILT DRAWING PARCEL ID NUMBER: - OSP101059 017-421-10 TOP OF TANK AT INLET = 95.26 INVERT OF BUNG AT INLET = 94.67 FINAL GRADE = 96.13+ 4" INSULATION FINAL GRADE = 97.39-97.55 ST1 ST2 —_�/ATOP OF TANK T OUTLET = 95.26 NEW 1000 GALLON SEPTIC TANK INVERT OF BUNG AT OUTLET = 94.53 BOTTOM OF TRENCH 85.58 RELATIVE ELEVATION OF BOTTOM OF TESTHOLE = 79.58 (DRY) — GARNESS ErNGINEERING GROUP, Ltd. m� CONSULTANTS & GENERAL CONTRACTORS, � 3701 E TUDOR ROAD. SUITE 101 • ANCHORAGE, AK 99507 • PHONE (907)337-6179 • FAX (907)338-3246 • WEBSRE:—gamea.mginmring.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: JOHN MITCHELL 907-269-0413 3 OF 3 LEGAL DESCRIPTION: DRAWN BY: T12N, R3W, SEC 25; N 330', E2, NE4, NW4, NW4, NW4 A.J.G. TYPE OF WORK: DATE: PROFILE AS—BUILT OF NEW SEPTIC SYSTEM 6/24/2010 (Rev. 01/05) 0 0 OF AL �p . .. ....... ....... ... ....... .J A. or ess.: / CE -79 �e . 12 4p. ��AoG �p) �Z_rofesslo� / On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP101059 Tax Code Number: 01742110000 Work Type: Septic Upgrade Permit Effective Dates: June 11, 2010 to June 11, 2011 Design Engineer: GARNESS ENGINEERING GROUP LTD Subdivision: T12N R3W SEC 25 Site Legal Address: T12N R3W SEC 25 E2NE4NW4NW4NW4 G:2840 Owner/Address: MITCHELL JOHN P & PATRICIA J PO BOX 113386 ANCHORAGE AK 995113386 Site Mailing Address: 7540 UPPER HUFFMAN RD, Anchorage Lot Size In Sq Ft: 54450 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either. A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued By Municipality of Anchorage • -� Development Services Department Building Safety Division s... On -Site Water 8 Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON—SITE SEWER/WELL PERMIT APPLICATION 001010 Set FOR A SINGLE FAMILY DWELLING Parcel I.D. 017-421-10 Property owner(s) JOHN MIT HELL _ Day phone 269-0413 Mailing address p-0. BOX 113386 ► ANCHORAGE AK a 99511 Site address 7540 UPPER HUFFMAN ROAD ' ANCHORAGE. AK Zip Code 99516 Legal description (Sub'd, Block & Lot ) T12N R3W SECTION 25• N 330' E2 NE4. NW4. NW4. NW4 Legal description (Township, Section & Range) N/A Lot Size 5q, NSU Sq.Ft. Number of Bedrooms 3 THIS APPLICATION IS FOR (® all that apply): Absorption Field ❑ Septic Tank Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ THIS APPLICATION IS AN: Initial ❑ Upgrade Renewal ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP Ltd. Permit/Rush Fees: yp 590 Date of Payment:�I 10 Receipt Number: o ('0 (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: GARNESS ENGINEERING GROUP, Ltd. - - CONSULTANTS & GENERAL CONTRACTORS 1 - May 28, 2010 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road, P.O. Box 196650, Anchorage, Ak 99519-6650 (907)343-7904 Ref: Proposed Septic Upgrade for T12N, 113R' Section 25, N 330' of E %_, NE 1/4, NNN''b, NW 1/4, NR"/., To whom it may concern: The existing 3 bedroom house is served by a private well and septic system. The septic system is in a state of failure and needs to be upgraded. We are proposing to install a new 1000 gallon septic tank and a deep trench type drainfield. One test hole was excavated on the property. The drainfield will be designed around the 30 foot radius of this test hole. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 4. TOPOGRAPHY: As can be seen on the attached design drawing the average topography below the drainfield is a 15-20 percent slope running approximately southeast to northwest. In short, there are no slope concerns. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. M.S. NOTZ Attached is a site plan drawing, a design drawing, one soil log, which are all part ofthe design package for this septic system. (Contact G.E.G. Ltd. for 7 page construction specification letter.) 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507-1259 Ph: (907) 337-6179' Fax: (907) 338-3246' Websitc: www.gamcsscnginccring.com PEREGRIN LOT 1 �u5 1 PEREGRIN S T 2 � i I � I SUSRNA 1\ UPPER HGFFMAN ROAD , \ \ / \ --------- �Jld ---- ---- EPnc '� - ARS�D EXISTING 712N, R3W. SEC 25, SEPTIC- 1 - W2, NE4. NW4, NW4, NW4 SYSTEM I / / XT�Hfjl PROPOSEDSEPTIC SYSTEM>��I-- / \ I \ I / \ T12N, R3W. SEC 25, / E2, SEL NW4, NW4, 100' WELL RADIUS 1 NW4 I I \ T12N, R3W, SEC 25, / \ W2, SE4, NW4, NW4, / \ NW4 / / / 100'WELL RADIUS \ JLOT I I /I T12N, FIN, SEC 25, NW4, NE4, NW4, NW4, N150' 6�2 1 00' WILL I IUS / S BEDROOM / MOUSE / T12N, R3W, SEC 25, NW4, NE4, NW4, NW4, 5750• i r --------------- I I I ZERKEL LOT 1 I I I GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS 6 GENERAL CONTRACTORS=•=---'_--^•_•'---^ j »1 c nioae eo•n. sort[ 101 . Awc�uc[. w1 eowr • w,o.[ uo -i1» • rur (vo ax•s • �[ .... .... PREPARED FOR: PHONE NUMBER: PAGE NUMBER: JOHN MITCHELL 269-0413 1 OF 3 LEGAL DESCRIPTION: DRAWN BY: T12, R3W, SEC 25; N 330', E2, NE4, NW4, NW4, NW4 A.J.G. TYPE OF WORK: DATE: SITE PLAN OF PROPOSED SEPTIC UPGRADE 1 5/28/2010 IR" 01AS1 0 0� QF �•��..S�� - e •••Or11C• ••• P E--7953 0 roleaaloo oma• NUMBER OF BEDROOMS: 3 GALLONS PER DAY (CPD): 450 PERCOLATION RATE/S: 17 MIN/IN PROPOSED APPLICATION RATE: 0.6 MINIMUM DRAINFIELD SO.FT.: 750 DRAINFIELD DESIGN: MAXIMUM DEPTH: 10' WIDTH: 2.5' LENGTH: 50' M.OA APPROVED SAND FILTER: N/A EFFECTIVE: 8' REDUCTION FACTOR: N/A LETTER THAT PERTAINS TO THIS DESIGN. TO OBTAIN A COPY OF THE LETTER CONTACT CEG. BY PROCEEDING FORWARD WITH THIS INSTALLATION, THE ENGINEER, WELL DRILLER, CONTRACTOR AND PROPERTY OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND EXISTING I I DRAINflEU)S TO l BE USED AS I RESERVE SITES I \ I E EXISTING SEPTIC I 7 TANK TO BE `e I ABANDONED PER UPC 1 I INSTALL DIVERTER \ CONNECT TO EXISTING SEWER UNE- ' SEPTIC DOUBLE CLEANOUTS OPOSED 1000 GALLON SEPTIC TANK AND DOUBLE CLEANOUTS KENNEL \ SHEp EXISTING 3 BEDROOM HOUSE . THII l SHALL HAVE ALL WELL RADII FLAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION DOUBLE CLEANOUTS OPOSED 1000 GALLON SEPTIC TANK AND DOUBLE CLEANOUTS KENNEL \ SHEp EXISTING 3 BEDROOM HOUSE . GARNLSS ENGINEERING GROUP, Ltd. - ...-. -"... CONSULTANTS & GENERAL CONTRACTORS + •--^��- =1 G TIp00 I . !UI[ 101 • NCHMI _ Mf OYiOF • FICIL (907)3] In • FM (OOF),IM " • �IIL w..p wM.aein PREPARED FOR: PHONE NUMBER: PAGE NUMBER: JOHN MITCHELL 907-269-0413 2 OF 3 LEGAL DESCRIPTION: DRAWN BY: T12N, R3W, SEC 25; N 330', E2, NE4, NW4, NW4, NW4 A.J.G. TYPE OF WORK: DATE. DESIGN OF PROPOSED SEPTIC SYSTEM 5/28/2010 (R. 01005) 4 �4 w : . .... ..... ....... •.J f e A. ss.: CE -7 53 :c ��D• •' •6Y,a roPoss1oP00o THII NOTE: CONTRACTOR SHALL HAVE ALL WELL RADII FLAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION GARNLSS ENGINEERING GROUP, Ltd. - ...-. -"... CONSULTANTS & GENERAL CONTRACTORS + •--^��- =1 G TIp00 I . !UI[ 101 • NCHMI _ Mf OYiOF • FICIL (907)3] In • FM (OOF),IM " • �IIL w..p wM.aein PREPARED FOR: PHONE NUMBER: PAGE NUMBER: JOHN MITCHELL 907-269-0413 2 OF 3 LEGAL DESCRIPTION: DRAWN BY: T12N, R3W, SEC 25; N 330', E2, NE4, NW4, NW4, NW4 A.J.G. TYPE OF WORK: DATE. DESIGN OF PROPOSED SEPTIC SYSTEM 5/28/2010 (R. 01005) 4 �4 w : . .... ..... ....... •.J f e A. ss.: CE -7 53 :c ��D• •' •6Y,a roPoss1oP00o 4/ CoNr-kov2S I � , 1 PE GRIN OT 1 1 P EGRI lbT I I I I U 5 0 1 1 _ I I PP OAC / _ - - - EPTIC AREA T12 R3W SE 25, T 2N, S 25, �i 4. 4, 4. 4• N1 W2 Nom. 4 4. // \ I•' I / 2N. 3 SEC 25. \ \ I NE4. 4 NW4, 50' / T1 R S CIf 1 SE4, I 100' WEL S IW4 T 1 I 2 R L T 1 \ T12N, R3W. SEC I W2, SE4, 4, / \ NW / \ � I / I\ I 11 LL S I \� S LE: I r-1 I I \ I \ I/ F o ........ ..gs�00 GAR_SS ENGINEERING GROUP, Ltd. p;?: 4 y*�Op m,[nnae ,ao, y,trtt CONSULTANTS 3 GENERAL CONTRACTORS =^++-� •-^-- .••••• ••• ••• ....... •••"" PREPARED FOR: PHONE NUMBER: PAGE NUMBER: a Gar •••••• ••••; ••••Q JOHN MITCHELL 269-0413 3 OF 3 'e ess: pp LEGAL DESCRIPTION: DRAWN BY: ,p' •. CErrZ ,O T12, R3W, SEC 25, N 330'. E2, NE4, NW4, NW4, NW4 A.J.G. �0 ee''S1.....• \eco TYPE OF WORK: DATE: 40°4pO��OOooI TOPO DRAWING OF SITE 5/28/2010 (R. 01105) RNESS ENGINEERING GROUP, Ltd. ��'�•' �I CONSULTANTS 6 GENERAL CONTRACTORS -- -----.,.•.,� ,I n 4 o • •. SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: TTZN, HJW, stc zx ry )JU. LZ, NL,, N-' PERFORMED FOR: JOHN MITCHELL DEPTH �_-__ ORGANICS (teen TEST HOLE 1 t `a • DATE DRY 5/25/2010 DRY 6/1/2010 t I - 6- IIIIIIIII I� I 311.11 30 v=2d eR YZA 3:45 umm • — 4 111111111 30 Rlu 1 3/4- vZyZp00. \ I [) 111111i 6- Y/VB. • 4:45 30 DEPTH TO GROUNDWATER DATE DRY 5/25/2010 DRY 6/1/2010 t I — 6- — :1 wwww ..•r CE -79 3 .(o y �1 D 'cto- DATE READING � I � / I \\ ;� S NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 5/26/2010 1 t I — 6- — I� I 3:45 30 4- eR 3 3:45 — 1 HOU — 4 4:15 30 4 1/4" 1 3/4- 5 \ I — 6- — 6 4:45 30 4 1/4- 1 3/4- + ,- TH# 1 _�� I , I , i SCALE: 1- _ 100' 1 DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 5/26/2010 1 3:15 — 6- — 2 3:45 30 4- 2- 3 3:45 — 6- — 4 4:15 30 4 1/4" 1 3/4- 5 4:15 — 6- — 6 4:45 30 4 1/4- 1 3/4- 18 1 PERCOLATION RATE 17 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 4.5 FT. AND 5.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: E YES ❑ NO SOILS LOGGED BY: ROB CAMPBELL PERCOLATION TEST PERFORMED BY: ANDREW CRAY COMMENTS: PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PRF RMED IN ACCORDANCE F 2 WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: Municipality of Anchorage Page f of 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW 91 000 Z PID Number: C)1'742.110 Name: A H FC Wastewater System: ❑ New 9 Upgrade Address: P.O. BOX 101oz0 ANcN. 19EIG ABSORPTION FIELD Phone: .l s(-' 1 i DO No. of Bedrooms: 3 wirpa 08,41 4 i Deep Trench ❑ Shallow Trent ❑Bed ❑Mound 6G Other LEGAL DESCRIPTION Soil Rating: 1,0 Total Depth from original grade: 12' GPD/S.Ft. 4.ot: Bleelc: subdivision: E'/2 NE Y4 NW'/4 Y4 Depth to pipe bottom from original grade: Cf.S Gravel depth beneath pipe NW'/y 1 NW Ft. O.S Ft. Township: N Range: 3 W z s, Section: Fill added above original grade: Gravel length: 30 • S Ft. Ft. WELL: E1e1ST1NG New ❑ Upgrade Gravel depth: I I] Number of lines: t Distance between lines Ft. Ft. Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material: 4f" rvc Ft. Ft. 150 SO.Ft. b-303 F-b°lo Driller: Date Drilled: Static Water Level: Installer: 5 A Dale installad:� / Ft. ! Yield : Pump Set at: Casing Height Above Ground: TANK �/ 0-6 GPM Ft. Ft. SEPARATION DISTANCES ,%Septic ❑Holding ❑S.T.E.P. To septic 'L'ApTanks� Absorption Lift Holding Public/Private Manufacturer: Capacity in gallons: From Field Station Tank Sewer Lines ,I ANcp NK Soo Well 67 101' 103'--. ---. 4o Material: STEEL J Number of Compartments: 1 wale°Q 7/vo' yioo' — — >�oo' LIFT STATION Lot7S' 4S 45' — L4 $' Size in gallons: Manufacturer: _ Line Foundation 20 50' f (oS _ _ O "Pump on" level at: "Pump off" level at: High water alarm at: Curtain Pump Make & Model Electrical Inspections performed by: Drain _ — — -' — tker 4' Ceecta( ororutaru an Pert : BENCH MARK Remarks: t a{tn t if if If dee Rn lArll.liar O p/1 ><s� �y crib is gqood_ Zfr';Ale Location and Description: ContliFe'oa o i Hirt( ie r(A Sae! "I" -roP OF NA Tvm cLosEsr A IVIT cite aa! �cen! !�e pY -C owe ne rawa�wa/-er to !`..f-; 2 -TO SEP T R 671111'71 %9 'the nZetf✓e 6VAace_Lunder Assumed Elevation: drririrAeeld showec< 'fate raie io he G /ot),o vhf////71 Ch 5' uH lizo wcV fnlu iii C?! % df fist Flattop Technical Ser 1(26 ENGINEER'SSEAL rc Aote 12 pad wa&- curt/ 4/! J aiNe u ree mc s �hAneDrth n tb. OF A se ef {j$� 35 Qj,�r+.•,,...°,,^,"��� goaoC f ian, eon Tt'rl COACre!Y wrH+ e. Ccipac.ly v 751>oe✓. Inspections performed by: FLATTOP TECH SVCS Dates: 1st 6//#/5/s * TH ,* ... .............../........ 2nd / �9 � ��.. .J........ Department of Health Hu �e`rvices approval wi...HEODORE f. 6J00RE N Reviewed and approved by' //moi e*> CE - 3539 �e Date: J7��—e� ����`0e, "........ 'i�N<Sr --=U_ /2 -Ula (1/91) MOA 25 Permit No. Stt� q 1000 2 Page 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 * Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report T12 N, R3 W Legal Description: E Y2, NE '/4, NW %4 Nw %4 NW %4 SEC 25- PID No.: O 174.2110 UPPER NUFFMAN ROAD _ 0 C_E•9 ESMT_ _ w 0 - NEW S'X301 DRAINFIELO ExIsrlNt. O F,WELL SeEPAGE PIT NEW Soo SEPTIC r) DRIVE I 3 BDr WELL HnVSE EX-ISTlN6 75d GA+- 5EPT1C TANk o n/ -Vf I M 72-013 A (2191) MOA 25 I 9 Flattop Technical Services 14530 Echo- Street 14: 101:I=L4;*:SLx_111 • ., THeOiW),., F.:hOC 2....... J'age,••. 3rlerl 1 .` , E . ..... �•(.{��� ° Permit No. 5W 110002 Page — 5 of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report -r17.n1, Raw ueScrlptlon: "'�/ •-r/ ,•"•'7 lvw /v rvw .-t cc .4s PID No.: u1r-r4Iry T.B.M. TOP of 100 ,-�` SAvNA TvgE CLOSEST To SEPTIC TANk ELEV= IOO.O EXIST. 750 6A Se P. -TANK GROVND ELE✓ 90.5r 10 _..INVERT ELEVt... 96'��' NEW 9S.2, Soo GAL EXIST, DIST. PIPE 'IN VER T. SEP. TANk SEEPAGE 82•2 52.1 PIr INVERT ELEV - $0 87.8 71 S., 8r•s' _SAND I NVE RTS: $0770h OF EXCA✓AT/Orl 86.3 SS:2 ems\) 70__ BOTTOM OFl MONITOR TVBE ENGINEER'S SEAL 7 ' LRy; 6� of �i°Ta All A✓ wtr_ ,i Flattop Technical Services 14530 Echo Street rchorcul)-, Flan -a •2-013 A (2/911 MOA 25 PAGE 1 OF MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 M/�/� �� ANCHORAGE, ALASKA 99519-6650 (YLL 1aP ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW910002 DATE ISSUED: 4/10/91 DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES EXPIRATION DATE: 4/10/92 OWNER NAME:ALASKA HOUSING FINANCE CORP OWNER ADDRESS:P. 0. BOX 101020 ANCHORAGE, ALASKA 99516 PARCEL ID:017�2110 LEGAL DESCRIPTION: T12N R3W SEC 25 E2NE4NW4NW4NW4 LOT SIZE: 54450 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: 1. SHOW DEPTH AND DIMENSIONS OF EXISTING PIT; VERIFY SOILS AND WATER TABLE LEVEL AT SITE OF PIT. 2. PROVIDE PERC TEST ON GP DURING INSTALLATION. MODIFY DESIGN ACCORDINGLY BASED ON PERC TEST. RECEIVED BY: 1:01(�"'�"�� DATE: Y1161M( ISSUED BY :J�� DATE: 1 ®Municipality ®f Anchorage Department of Health and Human Services 825 "L" Street Tom Fink, Mayor P.O. Box 196650 Anchorage, Alaska 99519-6650 January 29, 1991 Ted Moore, P.E. Flattop Technical Services 14530 Echo Street Anchorage, Alaska 99516 Re: Wastewater Permit Application Sec 25, T12N, R3W, S.M., PID No Dear Mr. Moore: !� Thank you for your permit application procedures used by - system permits. 071-421-10 January 14 letter concerning the referenced Your letter also expressed concern over the this office to review and issue wastewater - Based on our review of the referenced permit application we question whether the wastewater system even requires upgrading. Available information, including previous adequacy tests and your recent August 1990 test, indicates that the system is hydraulically adequate and is capable of absorbing in excess of the required 450 gallons per day for a three bedroom house. However, the wastewater system was apparently installed in the early 1960's and is undocumented. If you are seeking a Health Authority Approval for this property there are several criteria in addition to hydraulic adequacy that must be satisfied: 1. The bottom of the seepage pit must be confirmed to be a minimum of 4 feet above seasonally high groundwater. 2. The integrity, size and type of septic tank must be confirmed. 3. The approximate configuration and dimensions of the seepage pit must be confirmed and a percolation test performed adjacent to the pit to confirm adequate square footage of the absorption area. The size of the seepage pit should approximate the results of the percolation test. Kids Are Our Future �1 Ted Moore, P.E. January 29, 1991 Page Two If, after further investigation it is evident that the system requires upgrading, then the proposed system upgrade must be designed and constructed in accordance with current code requirements. In responding to your specific concern over the delay in reviewing your initial permit application, we acknowledge and apologize for an error made by this office in not properly recording the permit fee which was paid by Flattop Technical Services. This error, along with our attempt to honor your request that the permit not be issued until after January 1, did cause a delay in reviewing the permit application. However, your claim that the permit review process was held up because a staff member was on vacation is without merit. In responding to your overall concern that this office utilizes a cumbersome procedure for reviewing and issuing-permits,..,please- be assured that this office places a high priority on accurately reviewing permit applications and issuing permits in a timely manner. We certainly welcome any suggestions you might have on how to improve our existing procedures. When a permit application is submitted to this office and does not conform to the requirements specified in AMC 15.65 the application is returned to the engineer. In this particular situation, your permit application was clearly deficient and did not include specific design information required by code. When a permit application is found to be deficient for any reason it is returned to the engineer for correction. We do not attempt to resolve or negotiate these deficiencies over the telephone nor do we take the liberty to correct or "red line" work submitted by the engineer. It is the engineer's responsibility to ensure that the permit application is complete, accurate and in conformance with all municipal code and state statute requirements. We acknowledge that there will be situations where it is not physically possible for an engineer to design a wastewater disposal system which satisfies all code requirements. In those rare situations and where the code clearly allows flexibility, we will work with the engineer in an effort to resolve those deficiencies. Sincerely, - U\ V � hn Smith, E. rogram Manager, cc: Susan Oswalt Services CIVIL & ENVIRONMENTAL ENGINEERING • ENERGY CONSERVATION & ANALYSIS THEODORE F. MOORE, P.E. January 14, 1991 14530 ECHO ST. PH: (907) 345-1355 John Smith, Manager On -Site Services M.O. A. DHHS P.O. Box 19-6650 Anchorage, AK 99519 Dear Mr. Smith: ANCHORAGE, ALASKA 99516 On December 7 I filed the enclosed paperwork in support of a sewer upgrade permit application for the N330% El/2, El/2, NW1/4, NWl/4, NW1/4, Sec 25, T12N, R3W, S.M. When I paid the permit fee I attached a note requesting that the submittal be reviewed at that time for completeness, but that DHHS hold off on issuing a new permit until 1991, since there would not be time to do the construction before a 1990 permit would expire. After two weeks of no word from your office I called just before Christmas to inquire of miit status. I was eventually transfered to Susan Oswalt, who informed me tha e application, but > , was holding it unreviewed because she did not think the fee had been pard, and furthermore that she s leaving for a week's vacation and would not be able to look at it until after her return. I oro ow what led her to believe that I would submit a permit application without paying the required fee, or why she did.( not either call me to ask or check with your own accounting department to see if the fee had been paid, but n" L in any case I was able to demonstrate to her that the appropriate fees had been paid. G v After Ms. Oswalt returned from that vacation and on the day before leaving for another week's vacation she left the permit application at the front desk for me to pick up with a "pink slip" citing three OY imagined problems, which I subsequently discussed with you over the phone. Per your suggestion I returned the application with further explanation clarifying each of the points. Today we found the permit application again sitting at the front desk with a new "pink slip" from Susan citing some new concerns. The point I am trying to make, John, it that this process has become a ridiculously cumbersome procedure for dealing with a relatively simple permit request. I realize that your staff is tying to do a conscientious job, as am I. The procedures being followed, however, are a waste of your valuable staff time as well as of my time. If it doesn't look like the proper fees have been paid, why doesn't someone a� check it out instead of just sitting on the paperwork? If a staff member is going on extended vacations, o, M„E why not delegate the work to someone who is not on vacation? If there are technical questions with regud Q U to a submittal, why not have the reviewer give the engineer a call? I realize that I am not always sitting in my office, but I do try to leave my answPringmac n when 1 am gone and to call people back when I return. Thinking trat the design work was complete, ed my billing in to my client on December 7th, and I don't know to justify another bill for all this wasted d k� ' P With regard to the specific points contained in Susan Oswalt's latest "pink sheet", there is no feasible way to document the dimensions of the old seepage pit, as I explained in the written design narrative accompanying my original submittal. This system was installed in the late `60s before your Department kept records in the area, and in other similar situations the department has reapproved the systems without' 4A detailed as -built documentation. As described in the design narrative, I did conduct an adequacy test of the existing seepage pit last August and measured the absorption rate to be 840 gallons per day. It is only because the earlier approvals indicated that the house was then a two bedroom residence, that we undertook to add another bedrooms capacity to the system to accommodate the present thr bedroo residence. During the course of the adequacy test we measured the bottom of the pit to at 11 feet bow ground level. Our test hole was located 33 feet fiom the seepage pit standpipe and show d no wate o 16.5 feet, so there should not be cause for concern that the old seepage pit encroaches on shallo water table. Arq��S`P Ido not see any justification for Susan's assertion that the permit will call for a perc test o GP stratum. I had the sieve analysis run for the express purpose of establishing the permeability of the soil in lieu of a perc test, which in my judgement would have been too dangerous. The sieve analysis report demonstrates the material to be 54% gravel, 44+% sand and 1.4% silt. Because this is considerably coarser than the requirements for filter sand it will perc at a much faster rate, and that is the reason we have included two feet of filter sand in our design. To place unnecessary requirements for additional perc tests would cause unjustified expense to the property owner. With regard to Susan's comment about the installation possibly being too dangerous, please recognize that there is a significant safety difference between a small but deep backhoe excavated test hole and a 5 foot wide by 30 foot long drainfield, particularly after two feet of filter sand have made it that much shallower. Please give me a call if you would like to discuss this further. I hope you will take these comments in a constructive manner. I would like to think that we are all working together to efficiently achieve the same desired goals. Sincerely, Ted Moore, P.E. HS E IYN5 r3--, SBPrI c R EP t ac 0 M MN Csee \ NOTES J /SEE l NoT6 g U2 PER- H—U FMIA PRv Pos C -o lw" ? DA.4IN FfEGD c EXISTING SEEPA64 O PIT t I`� PRoPosev SOO GAL SEPTIC TANk DRIVE �Q I 3 6oRn HOUSE EXISTING £ 7SD GAL SEPTIC TgNK - I W I� I� NGTES: L p'5, 1,. NO oTHER to E6.4S ARE L,OCATEU WITHIN $00' OP - EXI.CTING UR PROPOSED we rc-w ArER o:S PoSAC SYSTGrl Corr PONSNTJ S. No SEPTtc S YSTC--m Con IUN ENT-( ARE LOCATED WITHIN too, Or wC-A LI EXCap7 ORI9�-)NhL SEPT'c TANK w. 613AND FAT NC -R !{TI, 3, THE PRo Pv1ED ISo ❑' w3AINF/ELO, P9144 4N0 r1jr'R 3 GDRn S6CpAGL- 13EU S IZE1� AT 3 X ISo x IS _ 67S d CAN 136TH CC-- 4ccolyovAr ED wfTHIN T90 I'Y'/S 0' pESIGNATG'D R6PLAr E/`IENT AR6AI I.I rr"tN 3O' of T. M # T TIi C^ TO Po CrgA PHY f*/'T/I IN Ioo'Or T. fl. 01 SLOPES TO 7,N C- AlW AT 1.. Iv% 0 I I D4HJ Flattop Technical ServiceE 14530 Echo Street Anchorage, Alaska : 9951( NTgI r.4 S F 1146® ALL• /S Ef_ i I `MOTE 2 N 3301 E'Tz, E''zI NWY41 NW Y4 NWYq 5aaS TI2 N R3W S' M. SITE PLAN sC4LC-.. 1°='50( TATE '• II /qO )WM BY: q THIS fs N01 A SKT{VC-YEo PLAT /41,1, A O CAT IONI ARE APPROXIMATE FRoM F.•'XISTING SEEPAGE PIT L WITH IE— 4" DIA NOR -PERF PIPE D-3034 a 4" DIA. PERF, PIPE p -S TOTAL Iii± DEPTH 0<-MDNITOR TOBE CLEANOUT M.T. j 0.0 30, MOUND (, ABOVE' SURROUNDING SOIL UNCLASSIFIED FILL FILTER FABRIC o. + 1' SEWER GRAVEL 2' MEDIUM SAND Fit -TER NATIVE CLEAN 5ANDy GRAVEL 5(; C T I ON A - A Flattop Technical Services 14530 Echo Street Anchorage, !?1r, c °1 T 5I� �C A) C- qi _E_412) NW Y,+ , NW Y4, NW 'lq SEC 2S, T12N,R3W, 5.M. DRAINFIELD PLAN ANp CROSS-SECTION SCALE:1"=S' DATE: Ilho DWN v: Yl. North 330', El/2, E1/2, NW1/4, NWl/4, NWl/4, Section 25, T12N, R3W, S.M. 7540 Upper Huffman Road, Anchorage Septic System Upgrade Specifications 1. The scope of the project consists of the installation of a new 500 gallon septic tank between the existing concrete septic tank and seepage pit, and the construction of a 5' wide by 30 foot long soil absorption drainfield to serve as an overflow to the existing seepage pit. Construction shall be as depicted on the site plan and design drawings. 2. All construction practices and material specifications shall conform with Municipal and State requirements. The contractor shall be responsible to obtain any necessary utility locates and to work around any utilities encountered. 3. The existing septic tank (presumably concrete) shall be exposed to allow verification of it's integrity and connections. If it is found to be in good condition, it shall be retained in service. with anew cleanout installed extending 12 inches above ground surface. A foundation cleanout shall be installed, and a double cleanout on the downstream side of the tank. A new 500 gallon septic tank shall be installed in the approximate location shown on the site plan, with a second double cleanout between it and the existing seepage pit. If the existing septic tank is found not to be in good condition, it shall be thoroughly pumped and either filled with soil or crushed and buried on site. A new 1250 gallon, two compartment, septic tank shall then be installed outside the 100 foot radius from the well. The waste line from the septic tank shall be plumbed into the existing seepage pit. 4. A new 5' wide by 30 foot long drainfield is to be constructed as follows: A new overflow waste line shall be installed just below the top of the seepage pit, and shall lead through at least 10 feet of undisturbed soil to the beginning of the drainfield. The drainfield shall be constructed by excavating approximately 12 feet of overlying soil to expose a 5' wide by 30 foot long level bed bottom in the clean sandy gravel found at that depth. A total depth of 2 feet of approved pit run filter sand shall be placed in the excavation. Next, a total of 12 inches of approved sewer gravel shall be placed on top of the filter sand, and the horizontal distribution pipe buried level in the gravel, such that the bottom of the pipe is no less than 6 inches above the top of the filter sand. A cleanout and a monitor tube shall be installed as shown and filter fabric placed over the top of the sewer gravel prior to backfill. The backfill shall be mounded approximately 6 inches above the level of the surrounding ground to allow for subsequent settlement. 5. A total of 5 inspections will be required during the course of the construction: (1) initial stakeout, (2) after the drainfield is excavated, but prior to placement of filter sand, (3) after the sand is in place, but prior to placement of sewer gravel, (4) after the gravel is in place and the pipes are installed, but prior to final backfill, and (5) after final backfill is complete. The inspection of the existing and the new septic tank may be conducted in conjunction with any one of the above inspections. Flattop Technical Services 14530 Echo Street linchoruge, Alaska 99518 North 330', El/2, E1/2, NW1/4, NW1/4, NW1/4, Section 25, T12N, R3W, S.M. 7540 Upper Huffman Road, Anchorage Sewer System Upgrade Design Narrative Due to the depth of the clean gravel stratum encountered in the test hole, it was not feasible to safely conduct a percolation test. Accordingly, the material was classified by laboratory sieve analysis (results enclosed) which showed it to be GP. Since this material will percolate faster than 1 minute per inch, the design incorporates a 2 foot thick sand filter to slow down the percolation rate to the the design rate of 1.0 gal./sq. ft./day. The existing wastewater disposal system was probably installed in the late 60's, and consists of a 750 to 800 gallon septic tank (presumably concrete) located 73 feet from the well, and a seepage pit of unknown dimensions, with the cleanout pipe located 112 feet from the well. No as -built inspection report exists, however the system was inspected and approved for 2 bedrooms three times in the 1970's. Flattop Technical Services conducted an adequacy test of the system on 8/2/90, at which time the average absorption rate was measured to be 840 gal per day. The proposed upgrade is necessary to obtain approval of the system for the existing three bedroom residence. The proposed project is configured to maintain the required separation distances from all existing wells and wastewater disposal systems, and thus should not have any impact on their continued operation. The designated reserve area contains 1445 square feet, which is adequate the proposed drainfield, plus another 3 bedroom seepage bed sized at 3 x 150 x 1.5 = 675 square feet. There are no known major surface drainage features within 200 feet of the proposed project, and thus the proposed project should not have any measurable impact on drainage patterns. _Flattop Technical Services 14530 Echo Street Anchorage, Alasl�a 99"' Flattop Technical Services 14530 Echo Street *?.•'tlR+ sEA��* Anchorage, Alaska 99516 0*Municipality of Anchorage ... ,,,,,,, �a,�•„ ,, DEPARTMENT OF HEALTH & HUMAN SERVICES Mto THEODORE F. MOORS: 825 •'L'• Street, Anchorage, Alaska 99502-0650 �� CE -3589 www SOILS LOG —PERCOLATION TEST 44®a;�protessrntal�°m�� PERFORMED FOR: ANFC % N6RITA6E R.E Klr 6REEN DATEPERrORMED: ID131/90. .1 W/ LEGAL DESCRIPTION:_{ 330' E Y,. E yt NW %4 NW �I ownship, Range, Section:5,5C 29 T i2. N R 3 W DEPTH 7 SLOPE SITE PLAN E 7 8 9 10 11 12 13 14 15 16 17 18 19 20 FILL. MATE=RIAS PT d- AsH SM REDDISH SANDY LOAM SM /6M SILTY, GRAVELLY SAND SOME COBBLES GP CLEAN SANDY GRAVEL RougbEb t?E8B6ES BLACK M ■■■■■■■M■■ Net Time(tgjy) Depth to Water Net Drop (IN) 12ePRESOA Ill.42 ONE ■■MEN 3o ■■ 11■■■■■■■■■ 10 23 s/ (2:32 10 "am S/8 0 ONE 22 '/2 YL WIN �����I�■�1■�III° 214 V WIN 12'.53 10 ■■■■■,,�E 3 1.03 10 ■ ■■■■■■■■■ 10 22 '/ s �I ■ ■■■■NE■■i� WAS GROUND WATER ENCOUNTERED? No S IF YES, AT WHAT LO O DEPTH? N.A. p E Depth to Water Aller DRY Monitoring? RL Dale: 11/6 - Reading Date Gross Time Net Time(tgjy) Depth to Water Net Drop (IN) 12ePRESOA Ill.42 7 3/4 2:12 3o 24 3/ t2:22 10 23 s/ (2:32 10 23 S/8 12:42 10 22 '/2 YL 0 12: y $ 214 V 12'.53 10 23 ' 4 3 1.03 10 22 1'13 10 22 '/ s r, PERCOLATION RATE .20 (minutes/inch) PERC HOLE DIAMETER _L -I TEST RUN B 6' ETWEEN s FTAND %.O FT COMMENTS i'tccfe l•la.� 5C 10W !/L.' .rtr CL/far ly v'C RC9Htn(/ 2' .:Fl*er sand 14 vee PERFORMED BY: FLATTOP TECN VCS I d T CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: l2 -z% !9a 72-008 (Rev. 4/85) RAM CONSULTANTS, INC, ENGINEERS VEVL0�.6i6 cLiNNERB SVsavEVOR9 TEST ON Field Sample CLIENT/PROJECT Flattop Technical Servi SOURCE 7540 Upper Huffman Rd. SAMPLED FROM TH-1 LOCATION UNK. LABORATORY TEST R&M PROJECT NO. 051003 ces LAB NO.. SUBMITTED BY Client FIELD NO. TH-1 DATE SAMPLED UNK. DATE REPORTED 11-14-90 DEPTH -15' DATE RECEIVED 11-13-90 GRAIN SIZE DISTRIBUTION I GLASSII-IGAI IUN %PASSING as COMPACTION SIEVE RECEIVED SPEC. UNIFIED AASHO FAA 2"% SAND 1�h" 100 - %SILT v 86 %CLAY - *- 75 FSV NFS* #10 Z/ TOTAL WT TESTED #16 #20 12 1864 GMS #30 REMARKS #40 5.6 *Assumed #200 !COARSESPEC I FINE SPEC I - ORGANIC CONTENT L.A. ABRASION LOSS LL U D_ DELETERIOUS MAT. MINUS #200 MESH 07 z SOFT FRAGMENTS w COAT& LIG. OR LTWT.PT. } CLAY LUMPS O STICKS &ROOTS FRIABLE PARTICLES THIN -ELONGATED ORGANIC COLOR FINENESS MODULUS SULFATE SOUNDNESS DEGRADATION VALUE ABSORPTION SPECIFIC GRAVITY—BULK SPECIFIC GRAVITY—BULK S.S.D. SPECIFIC GRAVITY—APPARENT OPTIMUM MOISTURE _ MAX. WET DENSITY. MAX. DRY DENSITY CORR. MAX. DRY DENSITY % FRACTURE METHOD NATURAL DENSITY NATURAL MOISTURE WEIGHT LOOSE WEIGHT RODDED y FROM..HERITAGE REAL ESTATE CORP. NOTE: This As-wit--shM-LnDA.be., sad for pr" m1renso other than financing I en,eslts, Under no circumstanoes Shu,,,o any data hereon be used ter 4onstruetion or for establishing boundary r fence lines. r % oplo ..... Fret Scq'/6 /" s Grp' �1 •n�R.� NC EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE REOORDED lk 'nrr9;ipHe1°�.� 11.15.1990 12:01 0&1% 0 AS -BUILT NO CORNERS SET THIS DATE I hereby ieertify that 1 have performed a Mortagea'a k spectlon of the following described property. - �Y'J'.�0 Anchoragge Recording Precinct Alaska, and that the lmprovl menta sltuated thereon are within the property lines and d not overlap or encroach on the property lying adjacent therA to, that +10 1m Memento an property lying ji ROOM theret encroach on the premises in question and that there are n roadways, transmission lines or other visible easoments o mt,la prOjlei,'ty eXeept 20 indicated hereon this T fty.of-.. .i0/y MAI— )SIA! Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL 4009 FOR A SINGLE FAMILY DWELLING�_C1�� Parcel 1.D. 017-421-10 COSA# 6SC-t 21IN 1. GENERAL INFORMATION Expiration Date: S-30-/ Complete legal description T12N, R3W, SECTION 25; E2, NE4, NW4, NW4, NW4 Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address 7540 UPPER HUFFMAN ROAD * ANCHORAGE. AK * 99516 TIMOTHY VANDERSOMMERN Day phone C/O AGENT 7540 UPPER HUFFMAN ROAD * ANCHORAGE, AK * 99516 Day phone JERRY DEWHURST W/ REMAX PROPERTIES Day phone 244-7237 110 W. 38TH AVENUE, #100 * ANCHORAGE, AK * 99503 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site 0 Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site `❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the f e , information obtained from the Municipality of Anchorage files and from my investigation and inspectiort, the a on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address' y 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name Engineer's Comments: JEFFREY A. GARNESS, P.E. In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for 3 bedrooms. Disapproved. Conditional approval for bedrooms, with the following Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Date 0 �� Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Nitrate Advisory Other By: (Rev. 11105) ON-SITE WATER AND WASTEWATER PROGRAM Original Certificate Date: lJ 3 © ! 2 Municipality of Anchorage ' Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 995196650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: T12N, R3W, SECTION 25; E2, NE4, NW4, NW4, NW4 Parcel ID: 017-421-10 A. WELLDATA*PER GEG INSPECTION. "SEALED IN BEDROCK PER ARROW PUMP AND WELL INSPECTION. SEE ATTACHED. Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) NO Date completed —1975 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth *55+ ft. Cased to **21 ft. Casing height (above ground) 12+ in. FROM WELL LOG AT INSPECTION Date of test NO WELL LOG 3/15/12 Static water level ft. 25 ft. Well production —9-10 m. 1.49 g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 ml. Nitrate y mg./L. Collected by: GEG. Ltd. Arsenic: _Qug./L. Date of sample: 3/15/12 B. SEPTIC/HOLDING TANK DATA *DOUBLE CLEANOUTS PRIOR TO TANK. Tank Type/Material SEPTIC/STEEL Date installed 6/18-19/2010 Tank size 1000 gal. Number of Compartments E Cleanouts (YIN) YES Foundation cleanout (Y/N) *YES Depression over tank (Y/N)NO Highwateralarm (Y/N) N/A Date of pumping 1 Pumper A+ 140 ✓Y? e, JC r L, C. ABSORPTION FIELD DATA *BELOW EXISTING GRADEI DATA IS FOR 2010 TRENCH Date installed 6/18-19/10 Soil rating (g.p.d./ftor /bdrm 0.6 System type TRENCH Length 50 ft. Width 2.5 ft. Gravel below pipe 8.05 ft. Total depth *10.41 ft. Eff. absorption area 805 ft' Monitoring tube YES Depression over field NO Date of adequacy test 5/15/12 Results (Pass/Fail) PASS For E bedrooms Fluid depth in absorption field before test E in. Water added 770 gal. New depth 23 in. Elapsed Time: 120 min. Final fluid depth 111 in. Absorption rate >= 450+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE If yes, give date 2010 TRENCH TESTED ONLY. TRENCH HAS 24"+ OF SOIL COVER AND HAS 2" OF INSULATION. D. LIFT STATION Date installed Size in gallons Manhole/Access(YM) "Pump on' level at in. "Pump off"level High water alarm level at in. Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ Absorption field on lot 100'+ Public sewer main N/A Sewer /septic service line 25'+ Animal containment areas 50'+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Holding tank N/A Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Properly line 5'+ Absorption field 5'+ Water main N/A Water service Wells on adjacent lots 100'+ 10'+ Surface water 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION o OF q 1 certify that t have determined through field inspections and e review of Municipal records that the above systems are in conformance with MOA COSH guidelines in effect on this date. . ...... I.......... Q f r G rness: Engineers Pri ted Name JEFFREY A. GARNESS DO 9. CE. 7 3 a rS 2C ZC�. 12'�owG c Date 9 Q�� P. COSA Fee $ IN -60 Date of Payment 57361ra Receipt Number OU_ 316 (Rev. 11105) Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage oars.4rq • Development Services Department Building Safety Division 5 r- On -Site Water & Wastewater Program 4700 Bragaw.Street P.O. Box 196650 - Anchorage, AK 99519-6650 www.muni.org/onsite` (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 017-421-10 COSA# 2- 1. GENERAL INFORMATION Expiration Date: -2 ZiOl / Complete legal description T12N R3W SECTION 25• N 330' E2 NE4 NW4 NW4 NW4 Location (site address) 7540 UPPER HUFFMAN ROAD * ANCHORAGE, AK * 99516 Current Property owner(s) JOHN MITCHELL Day phone 269-0413 Mailing address Lending agency Mailing address Real Estate Agent Mailing address 7540 UPPER HUFFMAN ROAD * ANCHORAGE AK * 99516 Day phone JERRY DEWHURST W/ REMAX PROPERTIES Day phone 276-2761 110 W. 38TH AVENUE, #100 * ANCHORAGE, AK * 99503 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual On-site N Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal ai ixed hereto and as of t,ie validation, datta show,-, baivw, i verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for -� bedrooms. Disapproved. Phone 337-6179 Date /t 3d/v O o p '...... 4 ............... Ass: v k'ZZ r0fessio�°oo Conditional approval for bedrooms, with the following stipulations�{u . I ,1, Of Ah' Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Nitrat Advisoryr Other i' BV", , Z:30 41 1 Original Certificate Date: (Rev. 11/05) Municipality of Anchorage 6F QV pts �L�•....� :�C • -� Development'Services Department - .. =.� .. .... x Building Safety Division J. •.A - On -Site Water & Wastewater Program 3 " ` E r Y 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS ,APPROVAL CHECKLIST Legal DescriptionTl2N, R3W, SECTION 25; N 330', E2, NE4 NW4, NW4, NW4 Parcel ID: A. WELL DATA *PER GEG INSPECTION. **SEAED IN BEDROCK PER AAROW PUMP AND WELL INSPECTION. SEE ATTACHED. Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) NO Date completed —1975 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth *55+ ft. Cased to **21 ft. Casing height (above ground) 12+ in. FROM WELL LOG AT INSPECTION Date of test 5/17/2010 G Static water level �5-��N ft. 26 ft. Well production g.p.m. 0.82 g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 ml. Nitrate 0.123 mg./L. Other bacteria 0 colonies/100 ml. Arsenic: ND ug./L. Date of sample: 11/ 15/201 Collected by: GEG Ltd. B. SEPTIC/HOLDING TANK DATA *DOUBLE CLEANOUTS PRIOR TO TANK. Tank Type/Material SEPTIC/STEEL Date installed 6/18-19/2010 Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (Y/N) *YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Date of pumping NEW Pumper - C. ABSORPTION FIELD DATA*BELOW EXISTING GRADE DATA IS FOR NEW DRAINFIELD Date installed' 6/!$-19/10 Soil rating OE/30r ft2/bdrm) 0.6 System type TRENCH Length 50ft0.5 . Width 2.5 ft. Gravel below pipe 8.05 ft. Total depth *10.55+ ft. Eff. absorption area 805 ft2 Monitoring tube YES Depression over field NO Date of adequacy test NEW Results (Pass/Fail) PASS For — bedrooms Fluid depth in absorption field before test — in. Water added — gal. New depth — in. Elapsed Time: — min. Final fluid depth — in. Absorption rate >= — g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date — D. LIFT STATION Date installed Size in gallons Manhwateraelaa�rmlevtlat "Pump on" level at in. "Pump ofF' level High Cycles tested Meets alarm &circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ Absorption field on lot 100'+ Public sewer main N/A Sewer /septic service line 25'+ Animal containment areas 50'+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Holding tank N/A Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION >"bF 11A - 1 certify that I have determined through field inspections and Q T .AVO, review of Municipal records that the above systems are in �• .. • ... • .. .. ............... . conformance with MOA COSA guidelines in effect on this Q date. O J A. Gar ess.: Engineer's Printed Name JEFFREY A. GARNESS CE9 • m© Date t! $D 10 Q��~ �L �.Q 4'�pG� 04edFOrofessi0 0\1=7 COSA Fee 2-50 Date of Payment R ZN ba Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage r �z • '� Development Services Departments Building Safety Division S A 8 Y Y On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www. ci. anchorage. ak.us (907) 343-7904 Water Well Advisory Certificate of On -Site Systems Approval (COSA) # OSC101321 During a recent COSA on-site inspection and test of the potable water supply well on T12N, R3W, Sec. 25; N 330' E2, NE4, NW4, NW4, NW4, the well's productivity was determined to be 0.82 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 3 -bedroom residence is 0.313 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. SGS. SGS Ref.# 1106181001 Client Name Garness Engineering Group, Ltd Project Name/# 7540 Upper Huffman Client Sample ID 7540 Upper Huffman Matrix Drinking Water Sample Remarks: Printed Date/Time Collected Date/Time Received Date/Time Technical Director 11/23/2010 16:28 11/15/2010 11:30 11/15/2010 12:05 Stephen C. Ede Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Hardness as CaCO3 56.6 5.00 mg/L SM20 2340B C 11/22/10 11/23/10 NRB Waters Department Total Nitrate/Nitrite-N 0.123 0.100 mg/L SM20 450ONO3-F B 11/16/10 AYC Microbiology Laboratory E. Coli Negative 1 100mL SM20 9223B A 11/15/10 DLC Total Coliform Negative 1 100mL SM20 9223B A 11/15/10 DLC Private Individual Analysis Alkalinity 101 10.0 mg/L SM20 2320B D 11/16/10 LP Aluminum ND 20.0 ug/L EP200.8 C 11/22/10 11/23/10 NRB Antimony ND 1.00 ug/L EP200.8 C (<6) 11/22/10 11/23/10 NRB Arsenic ND 5.00 ug/L EP200.8 C (<10) 11/22/10 11/23/10 NRB Barium 23.4 3.00 ug/L EP200.8 C (<2000) 11/22/10 11/23/10 NRB Cadmium ND 0.500 ug/L EP200.8 C (<5) 11/22/10 11/23/10 NRB Calcium 16200 500 ug/L EP200.8 C 11/22/10 11/23/10 NRB Chloride 18.7 0.100 mg/L EPA 300.0 D (<250) 11/15/10 11/15/10 SDP Chromium ND 2.00 ug/L EP200.8 C (<100) 11/22/10 11/23/10 NRB CO3 Alkalinity ND 10.0 mg/L SM20 2320B D 11/16/10 LP Conductivity 338 1,00 umhos/cm SM20 2510B D 11/16/10 LP Copper 14.9 1.00 ug/L EP200.8 C (<1300) 11/22/10 11/23/10 NRB Fluoride ND 0.100 mg/L EPA 300.0 D (<2) 11/15/10 11/15/10 SDP HCO3 Alkalinity 101 10.0 mg/L SM20 2320B D 11/16/10 LP Iron ND 250 ug/L EP200.8 C (<300) 11/22/10 11/23/10 NRB __SGS SGS Ref.# 1106181001 Client Name Garness Engineering Group, Ltd Project Name/# 7540 Upper Huffman Client Sample ID 7540 Upper Huffman Matrix Drinking Water Printed Date/Time Collected Date/Time Received Date/Time Technical Director 11/23/2010 16:28 11/15/2010 11:30 11/15/2010 12:05 Stephen C. Ede Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Private Individual Analysis Lead 1.01 0.200 ug/L EP200.8 C (<15) 11/22/10 11/23/10 NRB Magnesium 3930 50.0 ug/L EP200.8 C 11/22/10 11/23/10 NRB Manganese ND 1.00 ug/L EP200.8 C (<50) 11/22/10 11/23/10 NRB Nickel ND 2.00 ug/L EP200.8 C (<100) 11/22/10 11/23/10 NRB OH Alkalinity ND 10.0 mg/L SM20 2320B D 11/16/10 LP pH 8.30 0.100 pH units SM20 4500-H B D (6.5-8.5) 11/16/10 LP Selenium ND 5.00 ug/L EP200.8 C (<50) 11/22/10 11/23/10 NRB Silver ND 1.00 ug/L EP200.8 C (<100) 11/22/10 11/23/10 NRB Sodium 47900 500 ug/L EP200.8 C (<250000) 11/22/10 11/23/10 NRB Sulfate 33.8 0.100 mg/L EPA 300.0 D (<250) 11/15/10 11/15/10 SDP Thallium ND 1.00 ug/L EP200.8 C (<2) 11/22/10 11/23/10 NRB Total Dissolved Solids 239 10.0 mg/L SM20 2540C D (<500) 11/15/10 JJR Zinc 7.50 5.00 ug/L EP200.8 C (<5000) 11/22/10 11/23/10 NRB Aarow Pump & Well Service LLC (907)346-9355 Inspection Report 7540 Upper Huffman Casing inspected by camera down to 40'. Casing ends at 21' with open bedrock below. No liner found with camera. Brian R. Wille Aarow Pump & Well Service LLC ,:F/1V v M 33' 5c -c. Lr ye. xrp � snF a Q F.I ' "'� tn'fTYr+lIle �1 -iz N l VC �i r�. .fennel 7 � I 0 I A/ 4,"'. 7 ff - 4r,%, A ' Rtecevfi{i'ed //-14 ) 7,07-/0fk1 KS-BkgkT NO CORNERS SET THIS DATE �' I hereby eertify that I have performed 'a Mortagee's in- .� 4F .� 4( :spection of •the following described property: /EYZ� Z� �l%MOW,/YEA¢«nib jeC, 7.�. ei ee '7 0 /7-/g74// �/ ,V s e 4, °oe.m& R a Anchorage Recording Precinct, Alaska, and that the improve - ,/'{thereon are"within the property lines and do 1� not overlap or encroach on the property ling adjacent"iher6 K -property ying adjacent thereto to, that no improvements .on1 re6 WalcFrko encroach on premises in question and that there are nc NO -1255-S s2s5s = -' *� roadways, transmission lines or other visibleeasements or. 9F r,, sald,property ekcept:as indicated hereon. Dated at Anchorage, Alaska n this /� 75h day - EASEMENTS of �7G/y da 19 EASEMENTS OF -RI=CORD, OTHER THAN THOSE SHOWN ON THE RECORDED Yf= WALATKA & ASSOCIATES PLAT ARE IM SHOWN HEREON. HVL ��5,I Engineers and Surveyors MUNICIPALITY ANCHORAGE -`-' DEPARTMENT OF HEALTH &HUMAN SERVICES w}� Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 RECEIVED 343-4744 CERTIFICATE OF HEALTH. AUTHORITY JUL 1 1981 APPROVAL FOR A SINGLE FAMILY DWELLIN>>G�� �1Municipaiily cf Anchorago Parcel I.D. # O 1 7 4 21/ D HAA # 1. GENERAL INFORMATION Complete legal description E Yi I N1: Y4 NW yv N w % Nw '/v SE( 26- Location S Location (site address or directions) -7Sy0 UPPER +f UFFMAN Property owner A. N F. C. Day phone 5�1- l`100 Mailing address Pa BOY 10102o ANCH. AK 99516 Lending agency Day phone Mailing address Agent 14er-(!jf geal FRAM /t, Day phone S6 2 - 12 zz Address 3230 'C" S- AncAo aqe Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: If community well system, provide written confirmation from Stare ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA #21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I furtherverify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm —FLATTOP TECH SVC 5 Phone 3 LIS -- Address 1453o ECNo ST. AKcN, 99S/6 Engineer's signature '�/� ��� -< 'ALO",` Date 15_«/9/ 6. SIGNATURE Approved for Disapproved. M w C( �r . THEODORE F. L, RE 4Y '•. CE - 35a9 ......... «�a Conditional approval for Additional Comments bedrooms. bedrooms, with the following stipulations: NUTIC The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employeesof DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 1/91) Back MOA W21 Municipality of Anchorage Department of Health & Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: E Yi, N %1 NW'/4 NW %4 NW %y Parcel I.D. Sec 2,5, -r)zN, R3w A. WELL DATA Well type PR IyATE If A, B, or C, attach ADEC letter. ADEC water system number N.A. Log present(Y/N) Date completed OK 19'7s" Driller Total depth > 63/ Casedto BEDROCK Casing height 46 ), Sanitary seal(Y/N) Wires properly protected (Y/N) Public sewer main >/06 Public sewer manhole/cleanout 7/00 / Public sewer service line > /00 Petroleum tank NQN6 ORSER VED WATER SAMPLE RESULTS: Coliform O co f /room �C 0 Other bacteria O c 11100m -C Date of sample: 611719l Collected by: F!« Tech Svc FROM WELL LOG AT INSPECTION q i 6�26�q f LAJ Date of test Static water level 27 twirl Well flow g.p.m. o.6 g.p.m. y n- Pump level 62 SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot 67 ; On adjacent lots 5/00 Absorption field on lot 103 ; On adjacent lots > /00 Public sewer main >/06 Public sewer manhole/cleanout 7/00 / Public sewer service line > /00 Petroleum tank NQN6 ORSER VED WATER SAMPLE RESULTS: Coliform O co f /room �C Nitrate S•S i++y /-e Other bacteria O c 11100m -C Date of sample: 611719l Collected by: F!« Tech Svc B. SEPTIC/HOLDING TANK DATA CR16tNAt. -rANk / NEW TAN' Date installed PRio To 1974 6191 Tank size 7t0 6AL 11 Soo 6Ac Compartments DNE ONE Cleanouts (Y/N) y Foundation cleanout (Y/N) Y Depression (Y/N) High water alarm (Y/N) 14.4 • Alarm tested (Y/N) N•4 Date of pumping h4/gf SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s)onlot 67- oma% yank Onadjacentlots IID Foundation - 10l' To property line 4S Absorption field 2G Water main/service line Surface water/drainage >/00 72-026 (Rev. 3/91)F,ont Mon 21 CONTINUED ON BACK PAGE C. LIFT STATION A /j^. Date installed Size in gallons Vent(Y/N) High water alarm level - Manufacturer Manhole/Access (Y/N) "Pump on" level at "Pump off' level at Meets MOA electrical codes (Y/N) SEPARATION DISTANCE FROM LIFT STATION TO: Cycles tested Well on lot On adjacent lots Surface water SeepI 19ff conrfru� ea In lute '6or u D. ABSORPTION FIELD DATA W!" 6/QI a(yr M of ft p Date installed �l�l q/ Length 3o Width S Total absorption area Depression over field (Y/N) Results (pass/fail) ISO ❑� Peroxide treatment (pas( 12 months) (Y/N) e K.9 u6' f�� crib Soil rating 1.0 (5PD/5Q FT System type 5 WIDE DRAINFIEGp —Gravel thickness I Total depth 12 Cleanouts present (Y/N) Date of adequacy test, H•A, ME w FIELD for If yes, give date N SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot 103 / On adjacent lots 110 Property line yS To building foundation _ bS To existing or abandoned system on lot �0 On adjacent lots 7 5 Cutbank 7/00 Water main/service line `17 Surface water >/00' Driveway, parking/vehicle storage area 20 f Curtain drain NDNE ORSCR✓ED E. ENGINEER'S CERTIFICATION bedrooms 1 certify that I have checked, verified, or conformed to all MV nV HAA guidelines in effect on the date of this inspection. on / / o An adeQuaC Fed f of Me seep«qq�/jI1ASAowa< Aah t oa )?aet hf a sory a.n dzan?"udc re( Fc° fhrre yZtr,,om r9r0b(&nC '4'*QMNAVA Signature J %l4�� c- r�/fit° <•' °•'� t �3 �%72U G�Or`e. Jc / taO�C f7A ,i?, T:t ?� Engineer's Name / aye ...... .... .... ....... :.'�a j. Date ��-001141 e mEOuo2E F. s,tooRE C, -a539 •' ,' n Y1 t�t� HAA Fee $ I 0 • y" Waiver Fee: $ Date of Payment r� Date of Payment Receipt Number 1 - r Receipt Number 72-020 (Rev. 3191) Back MOA 21 CHEMICAL & GEOLOGICAL LABORATORY.. _cg A DIVISION OF COMMERCIAL TESTING & ENGINEERING CO. u LAeoReronr 5633 B STREET ANCHORAGE, ALASKA 99518 TELEPHONE (907) 562-2343 FAX: (907) 561-5301 r ANALYSIS REPORT BY SA14PLEfor WORKordex# 35315 Date Report Printed: JUN 20 91 0 14:24 - Client Sample ID:SEC 25 T1211 R3W 7540 UPPER HUFFMAN ' Client Name :FLATTOP TECHNICAL SRV PWSIII :UA Client Aect `.FLATTOT Collected JUN 17 91 6 14.00 hxs. BPO # - - PO # NONE RECEIVED Received JUN 17 91 @ 16:30 hie. - Req # Preserved vith :AS REQUIRED - Ordered By :TED MOORE 'I Analysis Completed :JUN 19 97. Solid Reports to: Laboratory Supervisor STEPHEN C.�EDEE ' i)FLATTOP TECHNICAL SRV Roleaced By Choml.ab Ref #: 912792. Lab Smpl ID: 2 Matrix: WATER Allowable Parameter Testod Result. Units Method - Limits ----_-_..------------------------------------- ------------- NITRATE-N 5.5 mg/l EPA 353.2 10 Sample ROUTINE SAMPLE COLLECTED BY: T.F. MOORE. 'PRES. TANK HOSE BIR. Romarks: — 1 v'y Tests Performed 'Tcy...,.=x'... See Speciale Instructions Above RD- None Detected See Sample Renkaxks Above NA. Not Analyzed LT -Lees Than, GT -Greater Than UA -Unavailable QNSras Member of the SGS Group (Socidt(5 Gk6rale de Surveillance) Loll" ' MUNICIPALITY OF ANCHORAGE DEPT. OF '=ACTH & ENVIRONMENTAL PROTECTION DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION 825 L Street - Anchorage, Alaska 99501 • AUG 16 1979 ENVIRONMENTAL ENGINEERING DIVISION 6. TYPE OF RESIDENCE _ Telephone 264-4720 RECEIVED REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10),days for processing. 1. PROPERTY OWNER ton-LIAM M. 6AA)II oN 7. WATER SUPPLY PHONE -. 0776 -/7// MAILING ADDRESS q (00! CV. snN/tLICA)UE �r.UTE # O/ n/C4GpQ E K- `�/�a�0 PROPERTY RESIDENT (If different from above) ❑ COMMUNITY- PHONE 2. BUYER - ,E,VM,UA;q /sl �, o�R¢ia� /� G(l.fszk�Ew/cz depth (attach log if available.) PHONE ala-�a7�9 MAILING ADDRESS .141 !!5-, 7 yN d�NuE /7�AJC/{o7e�4�E INDIVIDUAL/ON-SITE** 3. LENDING INSTITUTION _ ACfFSKA 1�ou5iti(, FiNfINCE C'o2R /4M,96 _-+/1lEr�zEToiJ PHONE MAILING ADDRESS NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 4. REALTOR/AGENT "- F4M 2,a -,d7-&---4 7,944,0A4,f".9 A*4rY. ZVO. PHONE MAILING ADDRESS /:r77 C 6 ee-.e-r, �yalre- -4-41oa, �,, 9950/ 5. LEGAL DESCRIPTION N3�a� E�,vw% N40 %N A/W % . ��, 77Z STREET LOCA ION 6. TYPE OF RESIDENCE NUMBER OF BEDROOMS C✓Y SINGLE FAMILY ED One ED Four ❑ Other 5T Two ❑ Five ❑ MULTIPLE FAMILY ❑ Three ❑ Six 7. WATER SUPPLY Ew ' INDIVIDUAL' * ATTACH WELL LOG. A well log is required for all wells drilled ❑ COMMUNITY- since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM d **If individual/on-site, give installation date Vim_ �— INDIVIDUAL/ON-SITE** If system is over two (2) years oldanadequacy test is required El PUBLIC UTILITY by this Department. LD(2_AL, NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010(3/78) q,L' pu MP�wJ� a CUD- THIS SIDE FOR OFFICIAL USE ONL. INSPECTION APPOINTMENTS - DATE RECEIVED _ TIME TIME TIME DATE DATE DATE INSPECTOR - INSPECTOR INSPECTOR DIRECTIONS: 1. TYPE OF RESIDENCE ❑ SINGLE FAMILY ❑ MULTIPLE FAMILY NUMBER OF BEDROOMS Cl ONE ❑ THREE ❑ FIVE ❑ OTHER ❑ TWO ❑ FOUR ❑ SIX 2. WATER SUPPLY ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLIC UTILITY Connection Verified PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED - 3. SEWAGE DISPOSAL SYSTEM ❑INDIVIDUAL/ON -SITE Ell PUBLIC UTILITY Connection Verified PERMIT NUMBER DATE INSTALLED INSTALLER - ❑Septic Tank or ❑ Holding Tank Size: If Tank is homemade give dimensions: SOILS RATING TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES WELL T0: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line - 5. COMMENTS 'a AJP�APPROVED FORBEDROOMS CONDITIONAL APPROVAL (letter must accompany certificate) ❑ DISAPPROVED DATE q BY (Title) - LEGAL DESCRIPTION 72-010 (Rev. 3/78) 3 ; Z'_'OF SHEET - Joho m.- Lambe, P.E. 4303 North Star Street Anchompe, Alaska, 89503 907-279.8056 REFERENCE:'�d'� DATE, % PERFORMED BY: LEGALDESCRIPTION: NS _' '% 4r' t1w,y yiey%H yup%. Ste: 23� 7- /2 Sw,S 41 'DEPTH BELOW METER READING GALLONS PIIMPED TIME RE ENCS I NET , �/0 7970 S"O A - Z = ozQ oo /a: z 8'-7g ` 6d ". 9 ' 6 1kl 6 220 130 0. ' ?_ 274 3 7C)5 /D�` ii¢ZU SOC/ //•'�i`7 S-7 7'—/9�gi /e" 3I ,-,OUNICIPALITY OF ANCHOR, g6 ��� DEPARTMENT, JF HEALTH AND ENVIRONMENT PROTECTION 1' 825 L Street, Anchorace, Alaska' 99501 �j 264-4720 wv Date Received: November 16, 1977 #1: Time -.1,60-0 . #2: Time ,---- ;k3: Time --- IDate _1�I�7�L�u I�. Date !J Date --- InsP—6'/��i�— -- / Inspri I:nsp ---- Ma A / 17N 1 �L11 P4 0 REQUEST FOR APPROVAL OF I VIDUAL SEWER AND WATER FACILITIES C ILml 1. Leading Institution Request: Alaska Mutual Sav D,ail.ing Address: Post office Box -1120 99510 — 2. Property Owner: William M. Bankst Mai -ling Address: Box 1713 99510 S Bank v//, S(-y,,cLl Phone: 274-35 Phone: 276-1711 3. Legal. Description: T12N R3W Section 25 N330' EZ E, NW4 4: Single Family Residence: (x) Multiple Family Residence: ( ) Number of Bedrooms: Number of Bedrooms: Two 5. Well System: Individual Well (x)� Community/Public System ( ) Permit # Depth of Well Well Log on Pile ( ) Construction Bacterial "Analysis 6. Sewage Disposal System: On-site System (x:r Public Utility ( ) Permit # Installed Installer Septic Tank Size J _ Manufacturer Absorption Area Soils Rate Material 7. Distances: Well to Septic Tank to Absorption Area —_ to Sewer Line Nearest Lot line _ Absor.pti.on Area to Nearest. Lot Line $age Two Department of Health and Environmental- ProteCtlOn Request for Approval of Individual Sewer and Water Facilities Legal Description: T12N R3W Section 25 N330' E2.Ei NA NA Nn _ Comments: Affadavit Attached: ( ) Letter. Attached: ( } Approved: _LSC. Date: �1 _ Disapproved: ----! -- Date: ---� Department Worksheet: Sheryl G. Smith X74-3561 Ext. 246 11 1 2 3. 4 5. GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" St., Anchorage, Alaska 99503 274„=4561 - REQUEST FOR APPROVAL OF << INDIVIDUAL SEWER & WATER FACILITIES Type of Inspection: CMRO VA Property Owner: William M. Bankston Mailing Address: Box 1713 Anch. Al, Name of Buyer: -0- Mailing Address: Day Phone Name of Lending Institution: Alaska Mutual Savings Bank Mailing Address: P. 0. Box 1120 Name of Realtor or Agent: -0- Mailing Address: FHA CONV xxxx Phone 276-1711 274-3561 6. Legal Description: North 330' of E 1/2 El/2 NW 1/4 NW1/4NW1/4NW1/4 See. 25 T12n R3W Seward Merd. Location: NHN Upper Huffman Rd 7. Type of Facility to be inspected: single Family No. Bdrms. 2 8. Water Supply Type of Supply: Public Utility Individual xx If Individual, number of dwellings presently served If Individual, depth of well 9. Sewage Disposal System Type of System: Public Utility Individual (on-site) xx If Individual, date of installation EQ -037 (1/74) U £tete- ` / LL-ps GREATER ANCHORAGE AREA BOROUGH ��� Q Department of Environmental Quality U 3330 "C" Street, Anchorage, Alaska 99503 274-4561 /IC1 ,�. Date Received July 26, 1976 Ssp�� Time of Inspection M Date of Inspection REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR Conv. r 1. Approval requested by: Alaska Mutual Savings Bank�i% Doreen Mailing Address: Post office Box 1120 2. Property Owner: H. Russel Holland Mailing Address: % 506 West 6th Avenue Phone: 274-3561 Phone: 272-4471 3. Legal Description; T12N R3W Section 25 N330' of EZ E2 NW; NW, NWa 4. Location: NHN Upper Huffman Road 5. Type of facility to be inspected Single Family No. of bedrooms 2 6. Well Data: Individual 7 A. Type C. Construction Sewage Disposal System B. Depth D. Bacterial Analysis on-site system A. Installed B. Installer C. Septic Tank: 1. Size 2. Manufacturer D. Seepage Pit E. Disposal Field: l� 8. Distances: 1. Absorption Area Total length of lines 2. Material A. Well to: Septic tank Absorption area ,:Sewer Lines Nearest lot line Other contamination B. Foundation to septic tank Absorption area C. Absorption area to nearest lot line EQ -034 (1/74) Page 1 of two pages Page 2 of two pages -Rest.for Approval-,of',Individual 'meter & Water Facilities Legal Description XNX T12N R3W Section 25 N330' of E2 E2 NW4 NW -'4 NA Comments Approved Disapproved Date * Approval;Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM G �--o ?A d o "= CQ- a" -d certifv that the information contained in this request for approval to be a true an, are operating satisfactorily. SIGNED Date EQ -034 (1/74) MUNICIPALITY OF ANCHORAGE • DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 2510 East Tudor Road, Anchorage, Alaska 99504 276.2221 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER and WATER FACILITIES 1. Type of Inspection: CMRO VA FHA '4uNIClPALI f y Dept. OF OF ENVlRONMENE TALR �E ECTlON JUL 2 6 1976 RECEI QED CONV XXX 2. Property Owner: H. Russel Holland Mailing Address: c/o 506 W 6th Ave Anch AK Day Phone: 272-4471 3. Name of Buyer: William M. Bankston Mailing Address: u n Box 1713 Anch, Ax Day Phone: 276-1711 4. Name of Lending Institution: Alaska Mutual saving^ nark (Attn: Doreen) Mailing Address: P 0 Box 1120 Anch . Ax Phone: 974-1561 5. Name of Realtor or Agent: n / Mailing Address: Phone: 6. Legal Description: N 330' of E 1/2 E 1/2 NW 1/4 NW 1/4 NW 1/4 Section 25 T12N, R3W, S.M. Location: MHN Uner Huffman Road 7. Type of Facility to be Inspected: well & septic, No. Bdrms. 2 8. Water Supply Type of Supply: Public Utility Individual If Individual, number of dwellings presently served If Individual, depth of well 9. Sewage Disposal System Type of System: Public Utility Individual (on-site) If Individual, date of installation 72-003(3/76)