HomeMy WebLinkAboutMARVINS GARDEN LT 1Onsite File
3
� •'1.
mr
NNEW
ks 4�f
TI 2N R3W SEC 21 Lot 12
Municipality of Anchorage =
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program, 4700 Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650 Page 1 of 3
www.ci.anchorage.ak.us (907) 343-7904
ONSITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: OSP111144 PID Number: 015.271.15
NameMarvin Rader :
Wastewater System: ❑ New ® Upgrade
Address:
1 ane St., 99516-2634
ABSORPTION FIELD
Phone: Number of Bedrooms:
® Deep Trench D Shallow Trench O Bed D Mound D Other:
LEGAL DESCRIPTION
Soil Rating:
Total Depth from original grade:
1.2 GPD/F1'
11 Ft.
Block: Lot: Subdivision:
Depth to pipe bottom from original grade:
Gravel depth beneath pipe:
12
4 Ft.
7 Ft.
Township: Range: Section:
Fill added above original grade:
Gravel Length:
0 Ft.
36136 Ft.
Well: [_1New EJUpgrade
Gravel width:
Number oflines:
Distance between lines:
313 Ft.
2
17.1 Ft.
Classification (Private, A, B, C):
Total Depth:Cased
to:
Total absorption area:
Pipe Material:
ExistingPrivate
Ft.
Ft
1008 Flr
3034 PVC
Driller:
Date Drilled:
Static Water Level:
Installer:
Date lcalalled:
Ft.
Dean Construction
7129/2011
Yield:
Pump Set at.
Casing Height Above Ground:
TANK
GPM
Ft.
Ft.
SEPARATION DISTANCES
® Septic ❑ Holding ❑ S.T.E.P. ❑ Other:
To
Septic
Absorption
Lift
Holding
ublic/Private
Manufacturer.
Capacity:
From
Tank
Field
Station
Tank
Sewer Line
Anchorage Tank
1250G1.
Well
101.3
109.2
s
Matenal:
Steel
Number of Compartments:
2
Surface Water
100+
100+
LIFT STATION
Lot Line
1U+
75.6
size
Manufacturer:
Gal
Foundation
105.4
113.6
'Pump on' level at
'Pump off, level at:
High water alarm at:
1
in.
in.
in.
Curtain Drain
50+
50+
Pump Make B Model
Electrical Inspections performed by:
Remarks:
First 30' of new service line encased in 6" sc40 PVC
BENCH MARK
Location and Description:
Top of Well Vault
Assumed Elevation:
100.0 Ft.
Engineer's Stamp
Inspections performed by: PANNONE ENG. SVC, LLC Dates: 161 7127/2011
q4�.
2'd 712912011
���P�E,OF
Development Services Department Approval
:
`•;�i
s
"
Conditional Approval Date:
'
...... ...... .. ..... .........1.....
..............Illy
�y
Steven R. Pannone: f`i/a
��Cs'•.• No. CE 8149
/
Reviewed and approved by: t/' Date: J / 8 -1�2
0� .... ......
scv. oa/osl
tu
itaESS„�p�
CONNECTED TO EXISTING.,
CI SERVICE LINE. 4" PVC
//zo,
'INSIDE 30 LF 6" SC40
PVC CASING. INSTALLED
END OF CASING
WELL (E)
EmST'G 1,600g
SEPTIC TANK
f ABANDONED PER CODE
0
4BR y p I EXIST'G CRIB IN FAILURE
'HOUSE DC ABANDONED PER
101.3 9w
4
N-6-
D/W, mi
T
ty 1250g SEPTIC TANK (P)
INSTALLED DCO AND FS sg
C
RV DUMP NOT INSTALLEDDFS 1M 1 G33
NN DEW
TH1 UPGRADED DRAINFIELD (N)
(2EA) 36LFx7'EDx2.5'W, 1 1'TD
SWING TIES GARAGE
CO A
T1 105.4
108.9
111.8.
2 105.7
DCO f06.8 113.6
FS 118.4 X124.2
t
C1 1113.8 115:1
M1, 113.7 1'15.5
11C2 131-4 1,42.2
M2 .129.8 140.3
G,3
1,46.4 153.0
'.M3 146 .5 152.0 NOTE
-C4 \139.5 135;5 RV DOMR WAS
M4 T40.0 136,5 NOT INSTALLED
NOTES: PAMONE ENG SVC, LLCDote
RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 OF. A1_4 1/17/12
�
PHONE (907) 272-8218 FAX (907) 272-821100, Scale
-149 TH .1.7 0
T12N, R3W, SEC 21, LOT 12 . ..... P.I.D. NO
MARVIN & MARY RADER . I .... — —I
.St vR.Pnnone ,
PERMIT NO.
10901 HANE STREETCE 8149
6' OSPI11144
Anchorage, AK 99516 Sheet
PLAN s — 2 OF 3
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON-SITE WASTEWATER DISPOSAL SYSTEMS.
2. ALL WORK SHALL BE IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS.
3. SCOPE OF WORK: 4 -BEDROOM HOUSE, NEW 1250g SEPTIC TANK, NEW DRAIN FIELD, AND RV DUMP OUTSIDE 100' WELL
RADIUS
4. GROUNDWATER IS NOT EXPECTED TO BE ENCOUNTERED DURING EXCAVATION, AS EVIDENCED BY THE SOIL TEST HOLE
INFORMATION ABOVE 17 FT. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 17
FEET BELOW EXISTING GRADE, NOTIFY THE ENGINEER IMMEDIATELY.
TH-1 91.5
OORT—
SM
GW
94.0
NEW 1250 g
SEPTIC TANK
DESIGN PARAMETERS
UPGRADE SEPTIC SYSTEM
NO. BEDROOM: 4 (600 gpd)
TANK SIZE: 1,2508
PERC. RATE: 21.6 MPI
SOIL RATING: 0.6 gpd/SF
AREA ROD: 1000 SF
SYS. TYPE: TRENCH, 7'ED,
MIN LENGTH: 71.4 LF
USE:
(2EA) 36LFx2.5'WIDE, 7'ED, 4' TO
TOTAL AREA: 1008 SF
93.8 91.5 Filter Fabric
/ above pipe inv
F0.589.8 87.5JV4" diam.
drain pipe
n rock
w pipe inv.
-II�
828 80.5 ISI
- 2.5I--14.0 —{ 2.5I
SECTION
No groundwater
monitored
Wo
mo
-n.DL--
z
TEST HOLE
o
74.5
a0
S
w
5
o
o
z
ox
�o
I i
o
`F810 HDPE 2< U
z
=W
o�
FS
U
TO
OU
94.0
NEW 1250 g
SEPTIC TANK
DESIGN PARAMETERS
UPGRADE SEPTIC SYSTEM
NO. BEDROOM: 4 (600 gpd)
TANK SIZE: 1,2508
PERC. RATE: 21.6 MPI
SOIL RATING: 0.6 gpd/SF
AREA ROD: 1000 SF
SYS. TYPE: TRENCH, 7'ED,
MIN LENGTH: 71.4 LF
USE:
(2EA) 36LFx2.5'WIDE, 7'ED, 4' TO
TOTAL AREA: 1008 SF
93.8 91.5 Filter Fabric
/ above pipe inv
F0.589.8 87.5JV4" diam.
drain pipe
n rock
w pipe inv.
-II�
828 80.5 ISI
- 2.5I--14.0 —{ 2.5I
SECTION
No groundwater
monitored
PROFILE
ABBREVIATIONS
CU
Wo
mo
DUCTILE IRON PIPE
TH
TEST HOLE
o
FOUNDATION CLEAN OUT
'o
2
a5
CU
OI
CU
J
x
4!' Die Pert Pipe x�
U
t a
`F810 HDPE 2< U
PROFILE
ABBREVIATIONS
CU
COPPER
DIP
DUCTILE IRON PIPE
TH
TEST HOLE
FC
FOUNDATION CLEAN OUT
T#
TANK CLEAN OUT NO.
C#
CLEAN OUT NO.
M#
MONITOR TUBE NO.
R.I.
RIGID INSULATION
DCO
DOUBLE CLEAN OUT
DV
DIVERTER VALVE
FS
FLOW SPLITTER
TO
TOTAL DEPTH
B.O.G.
BELOW ORIGINAL GRADE
NOTES: PAMONE ENG SVC, LLC
RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211
T12N, R3W, SEC 21, LOT 12
MARVIN & MARY RADER
10901 HANE STREET
DESIGN NOTES Anchorage, AK 99516
LEGEND
W WATER LINE/
WELL RADIUS
— SS — EXIST'G SEPTIC
— SS — NEW SEPTIC
TREE LINE
' nLgAll►. 110/15/11
... . .... ......
NTS
P.I.D. NO
•teven •Ft. Pannone• j
P.•. CE 8149 /�
('lt�Fl40FESS0NP�`�
15-271-1;
PERMIT NO.
OSP111144
Sheet
2 OF 3
Permit Number: OSP111144
Tax Code Number: 01527115000
Work Type: Septic
Permit Effective Dates: July 20, 2011
Design Engineer:
Subdivision:
On-Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Upgrade
to July 19, 2012
PANNONE ENGINEERING SERVICE
T12N R3W SEC 21
Site Legal Address: T12N R3W SEC 21 LT 12 G:2634
Owner/Address: RADER MARVIN R & MARY
10901 HANE STREET ANCHORAGE AK 995161439
Site Mailing Address: 3000 O'MALLEY RD, Anchorage
Lot Size in Sq Ft: 173745
Total Bedrooms: 4
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By: Date:
Issued By: /~,,~- ~'}c~x..~~- Date:
MILJNICIPALITY
OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
Mayor Dan Sullivan
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. OI5--2-7/- t~--'
Property owner(s) ./4,~,4/~~ ~) /~,¢~z y
Mailing address }O?ol t~~ 6~ ,
Site address ~O~ol ~E
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section)
Lot Size 175/ 7~ Sq. Ft. Number of Bedrooms
Day phone
THIS APPLICATION IS FOR: THIS APPLICATION IS AN:
([~] all that apply)
Absorption Field E~ Initial []
Septic Tank [~ Upgrade ~
Holding Tank [] Renewal []
Privy []
Private Well []
Water Storage []
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signa~;rr~Sf ~)r~per{y o~vner or authorized agent)
Rush ~ --
Fees:
Date of Payment: '"'1
Receipt Number:
Permit No. O~¢ [\'\~L~
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
G:\Building\On Site\Forms\Client Forms\Permit App_010411 .doc (Rev. 1/11)
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@panengak.com
March 4, 2011
Municipality of Anchorage
Development Services Department
On-Site Water & Wastewater Program
4700 S. Bragaw Street
P. O. Box 196650
Anchorage, Alaska 99519
Subject:
T12N, R3W, Sec 21, Lot 12
Septic System Permit Upgrade Request
Ladies and Gentlemen:
I am writing to request a permit to construct an upgraded septic system be issued for this property. The
proposed systems will serve an existing four-bedroom house. Currently the lot is developed. The lot is
served by a private well. The existing crib is in failure and shall be decommissioned per code. The existing
tank shall be decommissioned per code and a new 1250g septic tank installed. A new drain field will be
installed east of the existing field and will be sized to handle a four-bedroom waste stream. The surrounding
developed lots are served by private water systems. The private wells are located over 200 feet from the
proposed soil absorption system.
1. Soils. A single test hole was excavated by Pannone Engineering Service in June of2011. See the soil
log attached. Ground water was monitored for seven days. No ground water was monitored to a depth of
seventeen feet (17') below ground level after the monitoring period. Bedrock was not encountered in the test
hole. It is my opinion, based on the results of the percolation tests and overall soils appearance; an
application rate of 0.6 gallons/day/square feet should be used, using a conventional wastewater treatment
system.
e
Soil Absorption System Design.
a. See Sheet 2 of the design package
3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and the
existing drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water
and drainage ditches.
4. Topography: The average topography in the area of the proposed septic system is approximately 5
percent based on the survey information in the area of the septic system. Them are no steep slopes within the
vicinity of the proposed drain field.
Mai~ing: P,O~ Box 100117, Anchorage~ AK
Physical: 615 East 82r'''~ Ave, CuJte B6~ Anchorage, AK 99503
TeJephone: (907) 272-8218 FAX: {907} 272-8211
Page 2 of 2
5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification
that the review is complete and that there are no further comments is received from MoA On-Site
Department, the note will be removed and "Issued for Construction" drawings will be issued.
The proposed installation will not affect the future development of the surrounding or existing lots. There
are no wells or septic systems within 100 feet of the proposed septic location.
If you have any questions or concerns, please contact me at 272-8218.
Sincerely,
C)F
, .................... ?, ,,~
Steven R. Pannone, P.E.
Owner/Civil Engineer
Attachments:
Mai/lng: P~O, Box t002Z7,, Anchorage, AK 99510-02J, 7
Physical: 61J, 5 East 82~; Ave, Suite B6, Anchorage, Al( 9950~,}
Telephone: (907) 272-8218 FAX: (907} 272-8211~
., ; ~" WELL (E} ~'"'--L~D 7 '":::':f'::' ............ \, "". ", ' ........
" "/ \ '"",/ EXIST G 1,000 ' '" I
..' ~ INSTALL FCO-~ ~ /-SEPTC TANK ' ' I
~' .z ',. ~RR ~'~ ~ / ,,' ',, EXIST G CRIB IN FAILURE
'~ ~ ....... ~H~OSE~ ~ ' ~ "~ABANDON PER CODE
~ ~ '",. ~ 0 "'. '
z ~ ~ 1250g SEPTIC TANK (P) ~ I .~/~' ' ::.',, ,
__~ INSTALL DCO AND Y~ ~f~7 .~7 '
~ ," INSTALL RV DUMP BEFORE TANK~~~ //~ ~" .'
' ~'.. , ..' ,~ "'.~ '.....~,; ',.~~~. ~ , :' (2EA) 36LFx7 EDx2.5'W, 11'ID
: , ': , ', RV DUMP MUST BE
. ' , ' ~ ' .' OUTSIDE WELL RADIUS.
FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510~.~x..-~~ 7/20/11
Sc~J~ 5o.
T12N, R3W, SEC 21, LOT 12 ~'.~ P.I.D. NO
~ 315-271-1.
MARVIN ~ MARY RADER?~, ~eve~e~n .~
~0.
10901 HANE STREET
'i~ e~" .~ osP~
PLAN Anchorage, AK 99516 ~ ?~ .. ...... .~
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON-SITE WASTEWATER DISPOSAL SYSTEMS.
2. ALL WORK SHALL BE IN ACCORDANCE WITH THE AI~-ACHED SPECIFICATIONS.
5. SCOPE OF WORK: 4-BEDROOM HOUSE, NEW 1250g SEPTIC TANK, NEW DRAIN FIELD, AND RV DUMP OUTSIDE 100' WELL
RADIUS
4. GROUNDWATER IS NOT EXPECTED TO BE ENCOUNTERED DURING EXCAVATION, AS EVIDENCED BY THE SOIL TEST HOLE
INFORMATION ABOVE 17 FT. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 17
FEET BELOW EXISTING GRADE, NOTIFY THE ENGINEER IMMEDIATELY.
COVER-- ] TH- 1 ,/- Filter Fobric
OONORETE_/ 4jo' OR J %~'~.~,;;.![~f" // Drain rock 6"
DUMP BASIN --2.0 4.0 ~above pipe inv
-3.0 ~ ~ ~ 0.5 ~~4" diam.
~ drain pipe
FOOT VALVE SM 7.0 ~ Drain rock
DRAIN COVER -SLOPE BABIN
¢;,¢"-~--below pipe inv.
0.5 0.5 EXIS'PG :
2.5 14.0
GW
6.O
~CONNEC~TO J SECTION
4" SEWER LINE -- 17.0
RV DUMP No groundwater
o~-Z ~- ~- monitored
= o~' z ~o~ ~o8 z
~O ~ O = ~O ~ ~ ~4" Dia Peff Pi~
Q d ~ /F810 HDPE
/
~ ~ NEW1250g = ,.-
SEPTIC TANK ~ -
(2 fi~) DE[~ IRfi~GH 8~[ DESIG~
ABBREVIATIONS
DESIGN PARAMETERS cu COPPER LEGEND
UPGRADE SEPTIC SYSTEM DIP DUCTILE IRON PIPE
TH TEST HOLE W WATER LINE/
NO. BEDROOM: 4 (600 gpd) FO FOUNDATION CL~N OUT WELL RADIUS
TANK SIZE: 1,250g
PERC. RATE: 21.6 MPI T~ TANK CLEAN OUT NO.
SOIL RATING: 0.6 gpd/SF C~ CLEAN OUT NO. -- SS EXIST'G SEPTIC
AREA RQD: 1000 SF M~ MONITOR TUBE NO.
SYS. ~PE: TRENCH, 7'ED, R.I. RIGID INSU~TION -- SS NEW SEPTIC
MIN LENGTH: 71.4 LF DCO DOUBLE CLEAN OUT
USE: DV DIVERTER VALVE ~ TREE LINE
(2EA) 56LFx2.5'WlDE, 7'ED, 4' TD FS FLOW SPLICER
TOTAL AREA: 1008 SF TD TOTAL DEPTH
B.O.G. BELOW ORIGINAL GRADE
NOTES:
~~. D a t e
FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510
~,0~[ (~07) 272-8218 F~X (~07) 272-8211_. _.~."~ ~ ....~,~
T~2~, ~3W, SEC 2~, ~O1 ~2 ~-'~'~~~ ~.L~.
MARVIN & MA~Y ~AD~ .~3~s-27~-15
10901 HANE STREET '~,~ CE8149.'~ 0SPl11144
DES ON NOTES A ch° ge, AK 99516
~ ,~¢~ ....... ~-~ Sheet
~X~ 2 o[ 3
SOILS LOG - PERCOLATION TEST
TEST HOLE 1
SLOPE SITE PLAN
1 -- OR TOPSOIL
3 PT RED PEAT
5--
6 -- SM TIGHT GRAY TEST X
7 -- SILTY SAND HOLE
8--
10 --
12 --
GRAVEL
13 -- GW
WAS GROUND WATER SLOPE
14 -- ENCOUNTERED? N
15 -- IF YES, AT WHAT TH 1
16 -- DEPTH? -0-'
X
17 DEPTH TO WATER AFTER
BOH MONITORING? -0-
18 DATE: 6-29-11
DATE PERFORMED: 6-22-11
CLOCK WATER
READING DATE TIME NET TIME LEVEL NET DROP
READING
1 06122111 10:15 4.15
2 10:45 30 MIN 6.02 1.87
3 10:45 4~15
4 11:15 30 MIN 5.60 1.45
5 11:15 4.15
6 11:45 30 MIN 5.54 1.39
PEROLATION RATE 21.6 (min/inch) PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 6 FTAND 7 FT
COMMENTS: Test hole excavated by A+ HOME SERVICES. Test Hole was presoaked before perc test.
PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
NOTES: PANNONE ENG SVC, LLC
.... s.4511,. 7/2o/11
FOR CONSTRUCTION P.O. BOX 102954 ANCHORAGE, AK 99510 ~..~'."' ~/~'?['--..,~,~ Scale
PHONE (907) 272-8218 tAX (907) 272-8211 ~'~,.'hc~ TH ~' ".~_,~,~ NTS
T12N, R3W, SEC 21, LOT 12 ~ .......... ~ P.I.D. NO
01~_5_~271-15
MARVIN & MARY RADER
PERMIT
NO.
10901 HANE STREET
~, ~,~. · :c~%~'~'_ 0SP1111 44
SOILS LOG Anchorage, AK 99516 '~.~',L ...... .~,L~.~ Sheet