HomeMy WebLinkAboutT12N R3W SEC 33 LT 20 S264'
Tom Fink,
Mayor
Municipality of Anchorage
Department of Health and Human Services
825 "L" Street
P,O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
March 15, 1993
Daniel V. & Susan A Westervelt
PO Box 10-394
Anchorage, Alaska 99511
Subject: T12N R3W Section 33 Lot 20 S264'
Permit #SW920030, PID #018-191-17
The subject permit, issued March
single family well and/or on-site
expired as of March 13, 1993.
13, 1992 by this office
wastewater system, has
for a
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well
this office for documentation of the
close the permit.
log must be sent to
installation and to
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as-built inspection report must be sent to this office for
review, approval and documentation. All inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $200.00 for an
on-site wastewater permit; $75.00 for a well permit and
$275.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
Sincerely,_~h^ 1 .~E. ~
Jo ,
Program Manager
On-site Services
enc: Copy of Permit
cc: Tobben Spurkland, P. E.
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW920030
DESIGN ENGINEER:TOBBEN SPURKLAND,
OWNER NAME:WESTERVELT DANIEL V &
OWNER ADDRESS:2941 E 142ND AVE
ANCHORAGE, AK 99518
DATE ISSUED: 3/13/92
P.E. EXPIRATION DATE: 3/13/93
PARCEL ID:01819117
]LEGAL DESCRIPTION: T12N R3W SEC 33 LT 20 S264'
LOT SIZE: 87450 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISI~ ~
RECEIVED BY: ~ ~.~~~
ISSUED BY:
203 N 15th. benue~ Suite 206
ANCHORAGE, ALASKA 99501
(907) 279-3916
S2&4 '
SEPTIC SYSTEH DESIGN
LOT 20 SEC _ 55 T 1 '~N
DAN NEST£RVELT
Ixk) Gr'cnund Water tlr Iml=)erviaus L. ayer t(~ 16 -~t.
I~se ,~}~tandard Trench
Sc):il Rating. I::r'c~m test 2/14/92
Re(:lLdr'[]d Area per' E~edrc~c]m:
Finish~d Floor Elewatic]n L.c~we~t F1
Fc:~Lunclat i Ol] []]. ~,an Out. E]. evati
Ground [3L~F"~,'~Ce at Absorl:)tion F'ield
Test:hole Total D(ap~h 16
· ~, ~eet []over
Re)ok [)ept h 7
95.4
94
94
L[~,ngth o.F ]'rench~,~. ~;- " 4. / .~
5¥BTEM CONEIBUI~t~'IrI[IN
" 7 72
STANDARD TRENCH
TOTAL LENGTH 72 FT.
TOTAL HIDTH ~ FT.
TOTAL DEPTH 10 FT.
ROCK DEPTH 7 FT.
COVER 5 FT.
SEPTIC TANK 1250 GAL.
ABANDON EXISTING SYSTEM
PUMP AND CRUSH EXISTING TANK
PUMP, CRUSH, AND SACKFILL
EXISTING PIT
S264' Lc:fl: 2() ,~.c: 35 -r':L:aN R3W
The insta].lation of I~his septic system will not prevent wells
~rom be installed on the adjacent lots.
Ther'e are no developed er- natural surface / sub sur'Face drainage
courses on this or the adjacent lots.
The propc:lsed septic system wi. ll not change the general si. ope of
the area~ Ponding and/or conct-=ntration o'f sur-Face runo.~.~ will not
result ~rom this installation.
Septil:: System Des:i.
S264' Lo'E 20 Sec 33 T12N R3W
PERFORMED FOR:
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L' Street, Ancl~orage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
LEGAL DESCRIPTION:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20-
Township, Range, Section:
SLOPE
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Oepth to Walor Aller
MonitorinD? Date:
SITE PLAN
-I
Reading Date Gross Net Depth to Net
Time Time Water Drop
PERCOLATION RATE d~,~¢~ (m~nutes/inch) PERC FIOLE DIAMETER
TEST RUN BETWEEN ~ FI AND _2 FT
COMMENTS
PERFORMED BY: -- ~¢(¢(-)¢ ~'(~- I '~'~'~ ' CERTIFY THAT~T. H IS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. [)ATE: /~-~t~-, / ~/ / ¢/~/'~._
72-008 (Rev. 4/85)
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
LEGAL DESCRIPTION: ~>~:"~'~/;/' ' 0
Township, Range, Section:
1
2
3
4
5
6
7
8
9
10
11
13-
14-
15-
16-
17-
18-
19-
20-
COMMENTS
SLOPE
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Oepth Io Water Alter
Monitoring?
s
L
O
P
SITE PLAN
E
Reading
Date
Net
Time
Depth to Net
Water Drop
& ':~/~' ~I 'by/z.
'7~- I ~/~
PERCOLATIONRATE /g~/~r~--tmlnut0s/inch) PERCHOLEDIAMETER
TEST RUN BETWEEN /~ JZ_ FT AND
PERFORMED BY: ~-~{~-d~ -- I CERTIFY THA,7_~TH[S TEST WAS PERFORMED IN
ACCORDANCEWlTHALLSTATEANDMUNIOIPALGUIDELINESINEFFECTONTHISDATE. DATE I:¢--/¢ / /
72-008 (Rev 4/85)
14
I9
46
co
I
r' ! oSEPTI, C T4NK X
£ A £ 7-
I
45C1 ~ 45DI
,50 0
N
S~ 100
SCAL&
II
II
1.,50 £00 ,°.SO 300
-- 100 Fl',
I?RANDL S/D
S £64 FT SEC £0
F12N feSb/
~DN ~/ESFERVEL F_
/I DATE FEB, ]9, 1998
[BENCH 72' LON6 i0' ID 7' ROCK
I250 GAL SEP?IC ?ANX
N
X
,ole
/~EMDVE
EXIST
SEPTIC
I
I
TgM TDP D~1 SLAB
I ~I$$UIqE~
I }oo, oo
I
I
I
I
.J
£5 0 £5 $0 75 lOO I£5 1,50
SCAL[~ i' = 50 FT.
TUBBEN SPURKLAN3 P.E. Il
II
203 ~ JSTH, AVENUE
ANCH, AK, 99501
Ti£N RSF/ DATE, FEB. 19, 1992
])A~I_ ~/ESTERVEL T ~.. S;HEET, c°/3 ERin, 3034
i ~ Monitor Cleon
I250 go~ Sep~c
Cleonouts
m-- 3' Cover
Monitor
Ex/~, 5round
4'N/n Cover
Tonk
M/r~£1 140
7 Feet o£ Septic Rock
12.50 GAL £EPI'IC 'I~NK J
203 ~,/15TH, AVENUE
II
ANCH, AK, 99501 DANIEL I/ESFERVEL T DATE, MARCH i], 1992
..~9Jt7~aZD:aDlh 2941 EI4£NI? SHEET, 3/3 GRID, 3034
20~ W]5TH. AVE, SUITE 206
F'_ [:2 ,.
SPECIFICATIONS FOR SEPTIC SYSTEM INSTALLATION
S264' LOT 20 SEC o5 T12N RSW
1.0
GENERAL
Owner is Danie.~l Westervr~lt~ 2941 E 142nd. Ave. Anchor .....
aqe,Alaska .... 99516 F'hene ~.64 ._,74..., (wa 4~ ._,6~,., (ha
1.2 Engineer is t. he person or' egtity hired by the Owner to
inspect this project. Tine Engineer ~L~St lam recognized by the
Municipality o~ Anchorage~ Department o'F Health and Human
...:, Contractor is the person er entity hired by the Owner
to install i:hi~; project. The C~ntractor must be recognized
by the Municipality o~ Anchor"age~ Department o'F Health and
HLiman S~-~H~'vi c:es.
1.4 The Drawings, sheets :/ throLigh ~3, shall be part o~ this
spec:J.~ L cation.
:1..5 AIl. materials and workmanship shall meet the require-
ments o.F the Municipality of Anchorage~ Department ef Health
and Human Services~ the conditions o~ the permit~ and all
applicable rules and regulations c:urrently in effect.
:i..6 Ali excavatJ orl deptl-',s are adviscary~ and are to be
w:..~rified and may be modi.Fied in thc.? ~ield by the Engineer.
1.7 It is the respor'ls:[l:)ility of the Owner or the Contractor
to adher'e to the appr'c~ved design~ to veri~:y khat the speci-
;qied separat:i, on dJ.s'kanc:es are met~ and that the required
:i. nspections are performed.
1.8 The Contractor or tl-le Owner shall report {:o tine, Engi-
neer any c:)bser'ved condit:kcan which WC~L.~].C:I pL~t the sept:~c:
sys'kem in violation of State or Munic:Lpa]. r'egLl].atior'~s.
2.0 SEPTIC TANK
2.1 I-F there is an existing septic tarlk~ it may be used :i.{
i~ meets tf~e c:apac:iky r-equiremen'l: for the r"es:idenc:e. 'l"he
rani.:: sha].:l I:)e insl:aecEed by the Engineer~ and its water
I:ighi:ness al-iCJ S'kl~UC:kural i{]tegri'l:y shall be veri-Fied.
2.2 A new septic tal~k shall be cane ~abricated by either
Anchorage Tank and Welding or by Breer Tank
Speci~icaLions 'For septic: system installation
S264' Lot 21) Sec.._~'~'.:, [1.~.N RoW
Tine septic tank shall be a UPC-approved 'two-compartment
tarlk, constructed of 12 gau~e~ or better~ steel with bitu
mastic tearing. Tine tank slnall be set level on undisturbed
soi]L.'Tlne tank shall be c:overed w:Lt.h tine equivalent o~ foL.~r
.Feet o.F sell.
2.3 The septic tanl< shall be installed a minimum o~: five
'Feet .Frem the house ~oundation and a minimum o.F ~ive ~eet
from the absorpt:Lc~n area.
2.4 The se.~pt:i.c: tank sinai], be a minimum e~ 100 '~eet. ~rom any
well servinQ a single residence; 100 ~eet 'From any body
water', creeks or drainage ditches with '~lowing water; 150
feet ~rom Class "C' wells~ and 200 't:eet .From Class A or
Class B wells.
2.5 All p:i. pe cermet:riot, s to the tank shall be mechanical
watel'"tight calder couplings. Cleanouts shall be installed
as designated and capped with air-tight r'ain caps. Clean-
routs shall extend a minimum o'~: 12 inches above .Final gI"OLH]d
e]evatic:)n. Provisimns mhall be made'-Fer landscaping and
importation i~ topsoil.
2.6 LJ.{t'. statien sha].l be as manu'Fact:ured by Anchorage Tank
and Welding
3.0 ABSORPTION FIELD
3.] Gravel used in [~he absorption -field shall, be 0.5 to 2.5
inch sc. reened rock~ wit. h ].ess than 3% passing Ehe No. 200
Sand, used ~or levelin~] or ~or' ~iltering, slnall have an
e'F'Fective grain size between No.. 40 sieve and No. 18 sieve.
Uni-Form:~ty cee-~ic:ient: shall be less than 4. Not more tlnan
by ~eigl"rl: shall pass ~lne No. 200 sieve.
· ];.3 4-.:Lrlch I::~er'~c:)r'atecJ p:i. pe sha].:L be ASTM F810. For pres
sure distr"ibutic]r'l~ pipe shall be Schedu].(? 40 F:'VC or ABS.
3..4 Sel:Ld 4-:ir~c:l-~ pipe shall, be [last: Ir'on or ASTM D3034.
3.5 Monitor standpipes slnall be installed as shown. That
section e~ the pipe penetrating t:he gr'avel shall be per~o-
rat~.:~d~ e:[ther by drilling 0.5" holes on 6'-incl'~ centers ~r by
jm~ning a si?ct:ion o~ FS10 per~or'ated pile tea solid section
c)~ pi pe.
:3.6 Geotexti].e shal], be MiraTi 140.
3.7 Ineulat:Lon sba:L1 be extruded direct burial polystyrene.
Dow Chemical Styrm~:oam Fl:[ 40.
3.8 Tops~il shall be a mixture o~ 40-60% or'ganic matter~
Spec:i.fica'[::i. ons ~or septic: system installation
S264' L.o~. 20 Sec. 33 T12N R3W
20-'-:30% sand arid more that 20% silt· All quanhities are
3.9 Grass seed shall be Kentucky bluegrass.
4.0 INSTALLATION
4. 1 I_ocat e all underground u'hilities~ property lines,
· ~uture driveways~ e;.:isting or proposed water wells, water
ways~ surface and sub surface drainage .~acilities~ lakes,
ponds~ and all o'hher ~acilities requiring separation dis-
tances ~rc~m the pre)posed septic: system. Notify Owner ~r'
Engineer o~ any observed possible cc)n~lic'h.
4.2 Stake alignment of system wi'[-.h markers showing the
protective c:list, ances ~rom wells and water bodies.
4.3 Establish an elevation benchmark. This BM shall be
easily iden'hi~iable~ stable and permanent.. An arb'.itrary
elevation o.~ 100 c:an be assigned. Use slab over well utili-
der.
4.4 Install the tank as shown on the drawings. Recer'd the
inlet and outlet elevati(~ns o~ the tank. Tank shall be
placed on und:isturbed nat:lye soil.
4.5 Excavate the al:)sorpti¢~n ~ield. Bottom o~ exc:avatic~r)
shall be level arid scarified. ]]~ sidewalls smears~ they
~hall aisc) be scar'i.Fied. Record elevation o~ beginninq~.
middle and end o.~ trench. Record elevation o~ math corner
and center point o.F bed. []onstruct:~on equil:)menh shall not
eperate c)n the ~]oor o~ the excavation. Any material ~:om-
patted by the operation <:)~ the cc)ns6ruc'hion equipment shall
removed and replaced with uncempac'h[:ml mater':i, als.
4.6 Place the reck 'ko the depth spec i'Fied. Do not contami-
nate reel.:: w:i. th native materials or spoils ~:r'~m the exc:ava-
tion. L. evelL 'hhe rec:k sum'"~ac:e (+- :L") be~fore :installing the
pE?r-~erate(:J pi[)e.
4..'7 Instal] the cl:istributic:)n pipe. Record the e].ravation o~
each joint. For' pressl.u~e system solvent weld the jc~irrhs·
4.8 E]over
insul,uti on .~
the d:i. striL)ution p:Lpe with r'0ck, and cover the
w:i. hh gec:rhext:L:Le befcJre back'Filling and placing
4.9 Recorcl the fil~ished grOLu]d elevatior~ at the beginning,
middIe and end e'F trench. Record the -f:[nish (;round eleva-
tion at each cc~r'ner aed at the midpeint c~'~ the bed.
4. :LO Frurr~ish a copy o~: al:[ sLlr'vey notes te 'hhe Engineer.
Speci.Fications .~(:)r eeptic system installation
S264' Lot 20 Sec. 33 T12N R3W
5.0 INSPECTIONS
5. 1 A minimum o~ three inspections are requir~.~d. The
first inspection will be of the open excavation. At this
time the soil conditions will be observed and compared to
the design assumptions. Ground water conditions or presence
of bedroc:k will be verified.
The second irlspection will be after placement ef gravel
standpipes, distribution pipin(]~ tank(s) anti cr~her compo-
ner~ts as spec:ified~
'l-he t. hird inspection will be a~ter compl~rkion of the work.
Any deficiencies will be noted and the Contractor notified.
Such deficiencies shall be corrected within 'ken days.
All electr:ical work requires either an MOA electrical
inspectien or certification by an licensed electrician.
,.~.[-m].'t proof r3f inspectior'l or certif:~catior'~ te the Engineer.
oubm].t catalog data of all mechanic:al equipm(-i~nt.
5.4 Nok'.ify Engineer at least 24 heurs in advance of begin-
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
3330 "C" Street, Anchorage, Alaska 99503 274-4561
Date Received July 29, 1976
Time of Inspection
Date of Inspection
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
FOR
Cony.
10:00 a.m.
7-30-76 Friday
Buchholz
l. Approval requested by: Alaska National Bank
Mailing Address:
2. Property Owner:
Mailing Address:
3. Legal Description:
4. Location:
Pouch 7010 99510
Mr John J & Catherine Lower
Phone: 277-5511 x 31
Phone: 344-3720
Anchorage 99502~\~-{ ~
Box
6106
T12N R3W Sec )ff2~-4~f---~0 (.~ ~(0~1
Corner of Sabine & 142nd
5. Type of facility to be inspected
6. Well Data: Individual
A. Type Sm~.~J/~.~_./~i ,
Single Family
B. Depth
C. Construction ~/2.~.~_m_~, D. Bacterial Analysis
Sewage Disposal System: On-site system
A. Installed ..Ap.prox 1968 B. Installer
No. of bedr~gms~'2~-~%uj~le~x
152'
C. Septic Tank: 1. Size _ ~ 2. Manufacturer
D. Seepage Pit: 1. Absorption Area 2. Material
E. Disposal Field: Total length of lines
8. Distances:
A. Well to: Septic tank
Nearest lot line
, Absorption area
, Other contamination
, Sewer Lines ,
B. Foundation to septic tank , Absorption area
C. Absorption area to nearest lot line
EQ-034 (1/74) Page 1 of two pages
Page 2 of two pages - Req st for Approval of Individual % ir & Water Facilities
Legal Description Tl~ectJon 5 264 of 20
Comments
___Disapproved
Date
Valid for one year from date signed
Greater Anchorage Area Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
certify that the information contained in this request 'for approval to be a true and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED Date
EQ-034 (1/74)
7/~7/76
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF ENVIRONMENTAL QUALITY
88"3G~G'~'Sweet, Anchorage, Alaska99503 - 274-4561
2510 East Tudor Road, 99507
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER and WATER FACILITIES
MUNICIPALITY OE ANCHORAQF.
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
JUL 2, 9 976
RECEIVED
1. Type of Inspection: CMRO VA
2. Property Owner: Lower, John J. & Catherine L.
FHA CONY X×X
Mailing Address:
Name of Buyer:
Box 6106, Anchorage, 99502
Westervelt, Daniel V. & Susan A.
Day Phone
344-3720
Mailing Address: Box 6-101, Anchorage 99502
Day Phone 344-9090
4. Name of Lending Institution: Alaska National Baak, Metropolitan_. Branch
27'~''/~"~'
Mailing Address: Pouch 7=010~ AnchorafL~_ 99510 Phone 7-bbI±~ ext. 3].
5. Name of Realtor or Agent: Mary Gall. Compton Executive Realty Inc.
Mailing Address: 2810 "C" St, Anchoraze 99504 Phone 276-7777
6, Legal Description:
Location:
T12N, R3W, Sec%p 264 of 20
corner of Sabine & 142nd - see attached map
7. Type of Facility to be inspected: private well & septic syptem
8. Water Supply
Type of Supply: Public Utility
If Individual, number of dwellings presently served
If Individual, depth of well 152'
9. Sewage Disposal System
Type of System:
If Individual, date of installation
Individual
2 (duplex)
No. Bdrms. 3/1
Public Utility Individual (on-site)
approximately 1968
EQ-037 (1/74)
DAfE
NDIV DUAL
DEPARTMENT OF HEALTH AND SOCIAl. SEk,,,,ES
I)IVISIOI~ OF PIJBLIC HEALTfl
INI)IVII)IJAL AND SEMI-PIJI~LIC
BACTERIOLOG I CAI.,' WATER
-(--~-?-- t -/
ADDRESS
OFSOURCE
ZIP COD[
COMPLETE ?HIS SECTION _
ONLY IF,WATER IS AN INDIVIDUAL SUPPLY
READ INSTRUCT ONS
A N A L ¥ S I S OF.cF
SANITARIAN'S REMARKS
[] Room - Feet.
[] Ye ~] No Signature--S_
BACTERIOLOGICAL WATER ANALYSIS RECORD
.....
.-//
REVERSE SIDE 24 Ho,~r~
MF ReSullS
BEFORE
COLLECTING SAMPL ~