Loading...
HomeMy WebLinkAboutT12N R3W SEC 33 LT 45B Municipality of Anchorage • • Community Development Department Page 1 of 3 On-Site Water&Wastewater Program 4700 Elmore St. •P.O. Box 196650 Anchorage,AK 99519-6650 •http://www.muni.org/onsite•(907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181018 PID Number: 018-192-05 ❑ New II Upgrade Name: PAGET PLUNK ABSORPTION FIELD Address: • Deep Trench ❑ Shallow Trench 0 Bed 0 Mound 14250 SABINE STREET*ANCHORAGE, AK 99516 0 Other Phone: No.of Bedrooms: soil Rating: Total Depth from original grade: 687-5323 3 **0.6 GPasq.Ft. 10(MAX.) Ft. Depth to pipe invert from original grade: Gravel depth beneath pipe: LEGAL DESCRIPTION SEE DWG. 7Ft. F, Subdivision: Block: Lot: Fill added above original grade: Gravel length: 45B SEE DWG. Ft. 55 Ft. Township: T12N Range: R3W Section: 33 Gravel width: Beds Number of lines: Distance between lines: 2.5 Ft. - - Ft. SEPARATION DISTANCESTotal absorption area: Number of trenches: Dist.between trenches: To Septic Absorption Lift Holding Public/Private From Tank Field Station Tank Sewer Lines 770 8t].Ft. 1 Ft. Well •65'+ 100'+ - - 25'+ TANK IN Septic 0 S.T.E.P. ❑Holding 0 Other . Manufacturer: Capacity: Surface Water 100'+ 100'+ - - GREER 1250 Gal. Material: Number of compartments: Lot Line 5+ 10'+ - - N/A . HDPE 2 Foundation 5'+ 10'+ LIFT STATION Curtain Drain NONE KNOWN Manufacturer: I Gal. Remarks: PER CONTRACTOR,OLD TANK DECOMMISSIONED PER UPC "Pump on'level at: 'Pump off level at: (High water alarm at: •WR#OSV181003 Pump Make&Mode• Electrical Inspections performed by: 'TER ROGER J.SHAFER,P.E.1992 TESTHOLE PIPE MATERIAL EXISTING/ House to tank EXISTING Tank to D3034 drainfield Installer WILCO EXCAVATION Drainfield D3034 CO/MT D3034 Inspector GEG, Ltd. BENCH MARK (Assumed elevation) 100.00 Ft. Inspection Dates: 1st 2nd Location and Description: 2/26/2018 2/26/2018 3rd 2/27/2018 4th - BOTTOM OF TRIM @ NW HOUSE CORNER ENGINEER'S SEAL Community Development Department Approval ..••`s ' - ' i44! *41, ...it 4 iot Conditional approval: Date: �''•• Y• �, 4 '* 1• • le ess e i ,��p): C 7 53 '• z j � 3. 13—cg Approv-.• tn, — _ /" Date: LICEN,4. Ess` : #AECC884 1,IIIISIL**• Inspection Report_1-1-12.doc / PERMIT NUMBER: PARCEL ID NUMBER: OSP181018 RECORD DRAWING 018-192-05 / A B C 7 I FC01 16.7 24.0 62.7 / / SOUTH&WEST LOT LINES,AND \ \ FCO2 27.5 41.9 98.4 ALL WELL RADII FLAGGED BY \ ST1 36.4 45.4 51.0 / / SHANE HOLT,P.L.S.PRIOR TO \ ST2 41.1 49.1 50.5 CONSTRUCTION STMT 41.0 46.7 47.5 / \ I DBL1 42.7 50.9 50.4 DBL2 43.5 51.7 50.4T12N R3W SECTION 33 LOT 45D-1 CO3 48.8 60.7 56.7 / / / FD 76.4 97.4 89.7 RpOWg MT1 101.1 126.4 119.2 Lt CO1 97.0 124.0 119.8 I / APPROX1MAtE 100 WE / MT2 127.0 140.9 116.5 \ CO2 127.0 140.1 115.085 FOO WAIVER -- L (WR# SV181003) / / / / N k I \ \ / / , s,_____, s / \ \ I !SHED /' O`r L`C 9 7cP 0 / / 1 \ J 100'WELL RADIUS / / DRAINFIELD EXISTING 1992 \`NEW H E TANK 11250 GALLON it____ B / APPROXIMATE 1992 TESTHOLE n LOCATION PER MOA RECORDS BY . \ : ' ROGER J.SHAFER,P.E. ' DBL1 t P L2 ^ / :•:4•:..:.1:7, .1% ;.• ••� !.:ti•: 0 0� FCO7 • •• •• �DRIVEWAY�•:•, ;��,• r GO A EXISTING 3 W` II / ti BEDROOM HOUSE SEE ATTACHED EMAIL k\ FROM ARM SERVICES Z FD \ FCO 7 tu 2 11 \ = / y v ASSUMED LOCATION OF SEWER LINE / c (SEE ATTACHED EMAIL FROM ARM SERVICES) �4 14'+ ASSUMED LOCATION OF SEWER LINE;CONNECTED j GO › IN THE MIDDLE OF THE TRENCH PER CONTRACTOR / �� - - � / NEW DRAINFIELD BOTTOM OF TRENCH AND TOP OF TANK T12N R3W SECTION 33;LOT 52 INSPECTED BY MOA ONSITE EMPLOYEE TIM ECKLUND ON 2/26-27/2018 S ALE: li 1"=40' .\\\\\U 111 vA �`' 4 I. 1\ .* ., GARNESS ENGINEERING GROUP, Ltd • iI. • CIVIL&ENVIRONMENTAL ENGINEERS • • 3701 E.TUDOR ROAD.SUITE 101•ANCHORAGE.AK 99507'PHONE(907)337-6179'FAX(907)338-3246•WEBSITE:www.garnessengineenng.com •• PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ,O :, :ff ey Ga ss = PAGET PLUNK 687-5323 2 OF 3 ��J,'•I C1-7153 '_� PROJECT/LEGAL DESCRIPTION: DRAWN BY: .. '• �jt ' $ � T12N, R3W, SECTION 33, LOT 45B L.K.B. ��1�•(7110FESS��P��• TYPE OF WORK: DATE: LICENSE 1111"\\\�4 / RECORD DRAWING 3/2/2018 #AECC884 iPERMIT NUMBER: PARCEL ID NUMBER: OSP181018 RECORD DRAWING 018-192-05 FINAL GRADE=98.70-98.90 2"INSULATION ST1 ST2 PER CONTRACTOR — — TOP OF TANK @ INLET=95.34 TOP OF TANK @ OUTLET=95.26 P777trizziriiz, 'iri r INVERT OF BUNG @ INLET=94.39 NEW 1250 GALLON H.D.P.E. INVERT OF BUNG @ OUTLET=94.06 SEPTIC TANK BOTTOM OF TRENCH AND TOP OF TANK INSPECTED BY MOA ONSITE EMPLOYEE TIM ECKLUND ON 2/26-27/2018 1992 ROGER J.SHAFER,P.E. TESTHOLE MT CO B ORIGINAL GRADE @ — = FINAL GRADE HIGHEST POINT=77.78 =78.43 78.68 4.I1F FABRIC — :;::.. .::::•::: : .:::...:.::.:::::::..•::; ��-'"'QAC dr i.. A::<: ;% INVERT OF PIPE=74.78 g 'nIIIj:. 7.0 FEET Ns BOTTOM OF TRENCH=67.78 ti og RELATIVE ELEVATION @ BOTTOM OF T.H.=61.78 (T.H.DRY ON 3/17/1992) ••-\ -....... i........ Ay t. ...,31 -41.., • �•.: , '•.1 .. *•• ; GARNESS ENGINEERING GROUP — * • is i ' .., Ltd ; CIVIL& ENVIRONMENTAL ENGINEERS 0 0 3701 E.TUDOR ROAD,SUITE 101•ANCHORAGE,AK 99507•PHONE(907)337-6179•FAX(907)338-3246•WEBSITE:www.garnessengineering.com " • ; PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ..�• J�- re�A_S�rness : PAGET PLUNK 687-5323 3 OF 3 �.�I ;••r CE179 3 :/��� PROJECT/LEGAL DESCRIPTION: DRAWN BY: 6♦ t) f •/7 30r24•(`:: T12N, R3W, SECTION 33, LOT 45B L.K.B. ,,,�pRa• ... • .���. TYPE OF WORK: DATE: LICENSE 1..1v"`sillo.l. RECORD DRAWING 3/2/2018 #AECC884 J Z-2co -- /8 cs,,,,,.!!______p.i.„re, MUNICIPALITY OF ANCHORAGE went �,On-Site Water&Wastewater Program \O .„PO Box 196650 4700 Elmore Road mac'Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http://www.muni.orglonsite II I1 'Department On-Site Wastewater Disposal System Permit Permit Number: OSP181018 Effective Date: 2/9/2018 Work Type: Septic Upgrade Expiration Date: 2/9/2019 Tax Code Number: 01819205000 Site Legal Address: T12N R3W SEC 33 LT 45B G:3034 Site Mailing Address: 14250 SABINE ST, Anchorage Owner: ESTATE OF LANDERS AURORA A Lot Size in Sq Ft: 45015 Design Engineer: GARNESS ENGINEERING GROUP LTD Total Bedrooms: 3 This permit is for the construction of: Q Disposal Field El Septic Tank ❑ Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907)343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing 40111 Received By: Ar Date: Jia /" Issued By: 0. `�� Date: 9 1 c� Municipality of Anchorage P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 99519-6650 e (907) 343-7904 • Fax (907) 343-7997 http://www.muni.orq/Onsite Development Services Division On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV181003 COSA#: Permit#: OSP181018 PID#: 018-192-05 Legal Description:T12N R3W Section 33 Lot 45B Engineer: Garness Engineering Group Applicant: Paget Plunk Your request for a waiver of the required 100 feet horizontal separation from the septic tank to private wells has been approved. The approved separation distance is 65.0 feet to the well on T12N R3W Section 33 Lot 45B and 85.0 feet to the well on T12N R3W Section 33 Lot 45C-1. See engineer's waiver request for justifications. This waiver approval applies to the proposed septic tank only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: �/ / eaNte#� �� Approved by: fa21)60,64 Name of Reviewer **** VARIANCE/WAIVER REVIEW **** c � 8 9 /0 MUNICIPALITY OF ANCHO• �Community Development Department � shone: 907-343-7•� Development Services — `` fax`7- 343-79'.'7 On-Site Water & Wastewater Program Mayor Dan Sullivan On-Site Sewer/Well Permit Application For A Single Family Dwelling Parcel I.D. 018-192-05 Property owner(s) PAGET PLUNK Day phone 687-5323 Mailing address 14250 SABINE STREET *ANCHORAGE, AK 99516 Site address 14250 SABINE STREET *ANCHORAGE, AK 99516 Legal description (Sub'd, Block& Lot) T12N R3W SECTION 33 LOT 45B Legal description (Township, Section & Range) Lot Size Sq.Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING: (MiI that apply) Initial ❑ Single Family (SF) Absorption Field ® ® (w/wo ADU) Septic Tank ® Upgrade Duplex (D) ❑ Renewal ❑ Holding Tank ❑ Multiple Dwellings ❑ ❑ (SF and/or D) Privy Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: WELL TO SEPTIC TANK Distance: 65 FEET I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: 5-6 1 Waiver Fees: 1122 Date of Payment: 2/q112 Date of Payment: „2/1"11 Receipt Number: 09 YO( 6) Receipt Number: 09 Dq6 Permit No. G�PIWC)iV Waiver No. 05VIVV0O (Rev. 01/11) Quanics GARNESS ENGINEERING GROUP, Ltd Advanced Treatment `System CIVIL&ENVIRONMENTAL ENGINEERS m.�-r Dealer January 31, 2018 Municipality of Anchorage Development Service Department On-Site Water&Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Proposed Septic System Upgrade for T12N R3W Section 33 Lot 45B To whom it may concern: The existing 3 bedroom house is served by a private well and septic system. The drainfield is in a state of failure and needs to be upgraded. We are proposing to install a new 1250 gallon HDPE septic tank and deep trench type drainfield. We are proposing to utilize the existing 1992 testhole by Robert J. Shafer, P.E. in MOA records. Comments regarding the design are summarized as follows: 1. SOILS: See the attached 1992 soil log by Robert J. Shafer, P.E. which show the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface water concerns. 4. TOPOGRAPHY: See the attached topography drawing from the MOA GIS mapping. As can be seen on the attached topography drawing, there are no down-gradient slopes greater than 25% within 50 feet of the drainfield. 5. WAIVERS: We are requesting that your department issue a variance from the required separation distance of 100 feet from well to septic tank down to 65 feet for the subject lot, we are also requesting a waiver from well to septic tank down to 85 feet for the lot to the north (T12N R3W Section 33 Lot 45C-1). Justification for granting this waiver are as follows: • The existing tank has encroached on the well for approximately 26 years • The existing tank is steel; we are proposing to utilize a HDPE tank. In short, it will be an improvement on the existing condition. • Water samples were pulled on 1/30/2018 and the nitrate levels were 0.356 mg/L • Per MOA records, the nitrate levels in 1991 were 0.32 mg/L and 0.452 mg/L in 2016 for Lot 45C-1 • The septic tank is located downhill from the well. • The home is located between the well and proposed tank We are unaware of any adverse impacts this installation or waivers would have on adjacent wells or septic systems. I you have any questions, please contact us at 337-6179. Thank you for your assistance. Sncer0y, I Jeffrey', . - n s, .E., M.S. Presi.-.n 3701 East Tudor Road,Suite 101 *Anchorage,Alaska 99507-1259 Phone: (907)337-6179*Fax: (907)338-3246*Website: www.garnessengineering.com I T12N R3W SECTION 33 LOT 19 T12N R3W SECTION 33 LOT 20 S264' T12N R3W SECTION 33 LOT 21 --- 142nd �, I r / \ T12N R3W SECTION 33 -1 SEPTICCO / \ LOT 450-1 _ AREEb - ` UJ45D-1 \\ /// T12N R3W SECTION 33 / Z IAPPROXIMATE - I OPTIC// \\ 100'WELL RADIUS AR m 1 APPROXIMATE I \ '`^ / / I // 101'WELL RAQIQR."--1 \ ^/ \ \\\ / I1 // \ (( // \ \ \�-is -�/ \\ I 0 / I / BRANDL;LOT3A \1 100'WEA RADIUS I ' / \\I / I APPROX 100'WELLIMATE RAOIU I T12N R3W SECTION 33 LOT 46 1 = .11L I I --_ '' / CaPTIC AREb \• \ 1 // \\ / \ / /N s. / \\ / // ' `--- _ -- T12N R3W SECTION 33;LOT 53 T12N R3W SECTION 33 LOT 51 T12N R3W SECTION 33;LOT 52 VACANT NO CONCERN PER INSPECTION NO CONCERN;WELL ON SOUTH 1/2 REPORT;WELL ON SOUTH SIDE OF LOT OF LOT PER GEG FIELD INSPECTION S ALE: 1"=100' 441,16 " ;Ili ,11 '•* �� GARNESS ENGINEERING GROUP, Ltd ill14...°P..04. ••• = sCIVIL&ENVIRONMENTAL ENGINEERS r 3701 E.TUDOR ROAD,SURE 101•ANCHORAGE.AK 99507•PHONE(907)337-6179•FAX(907)338-3246•WEBSITE:www.gamessenglneeAn9.com ■ PREPARED FOR: PHONE NUMBER: PAGE NUMBER: i ,: A. Ga -ss iuim PAGET PLUNK 907-687-5323 1 OF 2 �• ,°,•• C• PROJECT/LEGAL DESCRIPTION: DRAWN BY: �� � � � T12N R3W SECTION 33 LOT 45B D.J.G. •<p�0••���''•,.,.�...•••. .41. TYPE OF WORK: DATE: LICENSE X11' l ESS i SEPTIC SYSTEM DESIGN SITE PLAN 2/1/2018 #AECC884 ����� J (- \ _ — N DESIGN CRITERIA: GEG,Ltd.HAS A 8 PAGE SPECIFICATION NUMBER OF BEDROOMS:3 LETTER THAT PERTAINS TO THIS DESIGN.TO GALLONS PER DAY 450 OBTAIN A COPY OF THE LETTER CONTACT NOTE:THE CONTRACTOR SHALL HAVE THE GALLONS PER DAY(GPD):'20 GEG.BY PROCEEDING FORWARD WITH THIS SOUTH&WEST LOT LINES,AND ALL WELL PROPOSEDPERCAPPLICATION RATE:MIN/INCH GPD/FP / INSTALLATION,THE ENGINEER,WELL DRILLER, RADII FLAGGED BY A REGISTERED LAND CONTRACTOR AND PROPERTY OWNER AGREE MINIMUM DRAINFIELD SO FT.:750 FTS / THAT THEY HAVE READ THESE SURVEYOR PRIOR TO CONSTRUCTION. 'PER ROGER J.SHAFER,P.E.1992 T.H. SPECIFICATIONS AND AGREE TO ACCEPT THE \ DRAINFIELD DESIGN: / TERMS AND CONDITIONS OUTLINED. MAXIMUM DEPTH:10 FEET / \ WIDTH:2.5 FEET PRIVATE WELL BELIEVED TO SERVE LOT 45D-1 AND 45C-1;PREVIOUSLY CLASS"C" T12N R3W SECTION 33 LOT 450-1 LENGTH:55 FEET / EFFECTIVE:7 FEET PER MOA RECORDS.NOW BELIEVED TO BE \' PRIVATE,ASSUMED 100'PROTECTIV ACTUAL SQ.FT.:770 FEET' ( RADIUS j L`� S r I / p%U I pPPROXIOCE 1(13 WE N / I 85 FOOT WAIVER REQUEST / I I \ / I-4 I \/ • / // PROPOSED 1250 GALLON HDPE SEPTIC�K; I \ INSTALL DOUBLE CLEANOUTS AFTER THE TANK. \ \ / SHED APPROXIMATE LOCATION OF EXISTING TOP OF BLUFF PROFESSIONALLY 1250 GALLON STEEL SEPTIC TANK TO / \ SURVEY BY SHANE HOLT,PLS \ \ ' / BE DECOMMISSIONED PER PC. / APPROXIMATE LOCATION OF 1992 DRAINFIELDINSTALL FCO IF ONE IS 1 PER CLEANOUT LOCATIONS PROFESSIONALLY \ I I 100'WELL RADIUS / SURVEYED IN BY SHANE HOLT,PLS.DRAINFIELD \ NOT PRESENT TO REMAIN IN PLACE FOR FUTURE USE I N 6g WELL VVa APPROXIMATE 1992 TESTHOLE \ ~_ P / REQUEST''R ' LOCATION PER MOA RECORDS BY Tq, 111 • , ,•1,•: . , , ,i .. 1r,. .../�: Y, •, ROGER J.SHAFER,P.E. ` B : . . r ,s.•, ,• : a .l• .- �`, DRIVEWAY .., PROPOSED DRAINFIELD .'• �•� ' C�` ��..••• / EXI EXISTING 3 •• M \\:„...---- \ / BEDROOM HOUSE / 1-• / z \ d \ w /w / gQai ASSUMED LOCATION OF SEWER LINE / PER TANK AND DRAINFIELD LOCATION \ >4,+ \ jP PROPOSED FLOW DIVERTER — ----- 'SLOPES 'SLOPES<25%WITHIN 50'DOWNGRADIENT OF THE PROPOSED DRAINFIELD.SLOPE INFORMATION N OBTAINED FROM MOA ARC GIS MAPPING T12N R3W SECTION 33;LOT 52 SCALE: 1"_40' ♦.♦viii\\ 44 P��•of h' w._ 41 , .i I •• *•. GARNESS ENGINEERING GROUP, Ltd " 4' ' . CIVIL&ENVIRONMENTAL ENGINEERS ,/`, 3701 E.TUDOR ROAD,SUITE 101'ANCHORAGE,AK 99507•PHONE(907)337-6179'FAX(907)338.3246'WEBSITE:www.gamessenOneeing.com 7 • PREPARED FOR: PHONE NUMBER: PAGE NUMBER: '/J- ey A.. -1a ess PAGET PLUNK 687-5323 2 OF 2 ���• CE 795 ,' PROJECT/LEGAL DESCRIPTION: DRAWN BY: -I ••,, 1111 aG� • T12N R3W SEC33 L45B D.J.G. �1ep••••z •,� J. TYPE OF WORK: DATE: LICENSE ,,11'"``��♦♦ SEPTIC SYSTEM DESIGN UPGRADE 2/9/2018 #AECC884 I 252 ..— I ..n I c. ---.. i --, 'II / I, \ Il \ 1 41 C•1 ) f \ As , ,,--- / .... ,r) ry 41, i /7 / / / •,;(° i ) / / .1.,1. 72A5 2A-I ._ .• 7 , . . A . 1. •\ 'i•')" 1 0 . 1 'i.c •:-',..t 1:52 b .. 1:.--. . .' 173\ --... .•' 1 VP QC, ....-------' -___..- ..... -1.sc' , . _.... 'P. / •-'' ?a . ......" .„_ f'l „/ ....s . 0 - --- 47 i.I„-”` -, .01$ ..„..., .. . S" \ t . ... . , ./ , .. ,,, .. -_. ... .___..... . _..... , . Iv ---7"-- eZ9/..,:- 4 ' i . 1 . ‘..... - PRELIMINARY - SGS Ref.# 1180422001 Client Name Garness Engineering Group,Ltd Printed Date/Time 01/31/2018 13:57 Project Name/# 14250 Sabine Street Collected Date/Time 01/30/2018 13:00 Client Sample ID 14250 Sabine Street Received Date/Time 01/30/2018 14:00 Matrix Drinking Water Technical Director Stephen C.Ede Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Waters Department Total Nitrate/Nitrite-N 0.356 0.100 mg/L SM21 4500NO3-F B (<10) 01/31/18 DMM Z. Er.,, .l6Not�E91i �Li r Municipality of Anchorage �. S'...G; ♦ t �. DEPARTMENT OF HEALTH&HUMAN SERVICES II"5; •G {1 825"L"Street, Alaska 99502-0650 "' r; N 89 59' W 299.73 i4z 0 N W Q SHED EL I .f oWELL O wl 0 f�i • 1 �' T ' cr 1. '� ° ,0,o s ° 9v iz ii �moon o W O �P• � .. � G , s0 Z 00 i • 0 H. DECK (f)I . DECK • • I I I{i IiI b. N 89 59' W 299.74 3 I � � LOT 52 i OS AS—BUILT SURVEY 1 " = 30 ' NO CORNERS SET THIS DATE I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY OF THE FOLLOWING DESCRIBED PROPERTY LOT 45B, SECTION 33, T 12 N. R 3 W. S.M. , PLAT 66-154 ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN ITHE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS Municipality of Anchorage Page I of DEPARTMENT OF HEALTH AN[::) HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P,O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: _ ~,~-~-~-'~:~---~ Address: Phone: -~2~;~f~ --~'~..~, ~.j, ~ rNo. of Sedrooms: LFGAL DESCRiPTiON Lot: ~ Block: Subdivision: WELL: [] New [] Upgrade ~f~n (Private, A,8~'~)~ GPM I Pump Set at: PID Number: ~:)1 ~) lg:~ ~ Wastewater System: [] New ~'Upgrade ABSORPTION FIELD Z~)eep Trench [] Shallow Trench [] Bed [] Mound O Other Soil Bating:~, .~ G,~O/Sq. Ft I ~.~/g Total Depth from original rode: Depth to pipe botlom from original grade: Grave depth beneath p pe Fill added above original grade: Gravel length: Gravel~p~h~ ~./J, & 't~-:>T~ ~ ! Number of lines: Total Depth: Cased To: Total absorption are~: Ft. Ft Date Drilled: Static Waler Level: Installer Ft.' i Casing Heighl Above Ground: Ft Ft. Pipe material:' ¢,~-r r,-t Date installed: TANK To From SEPARATION DISTANCES Septic Lift S~ation Well Surface Ws, ter Line Curtain Drain [] Holding [] S.T.E. Material: Capacity in gallons: Number of Compartments: LIFT STATION on" level at: M~ke & Model "Pump oft" le~'~..~LHigh water alarm at: Electrical Inspections performed by: BENCH MARK ~cation and Description: Assumed Elevation: Inspections performed by ~k~:~*3 ~, ,'~l,t¢"-~ ~.~ Department of Health and Human Services approval Reviewed a nd ap p r eyed by://~L~.~z~,~...~. ~)~.¢obvo~ ¢- Date: _¢7~_~//¢.~ 72-013 {I/91) MOA25 8ttAFER No. 3215 Permit No. '~ Page ~ of '~ Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On=Site Wastewater Disposal System and/or Well Inspection Report Legal Description: '"T'-I"~-N.~'~ ~1~ )! ~--__~.,, -?---~,-~-~, L..T ,44:::~ PiD No.: SEAL 81tAFEI~ No, 215 72~013 A (2/91 } MOA 25 /47./ R O. BOX 190708 * 2921 INTERNATIOi~AL A~R,F~ORT ROAD. ANCHORAGE!, ALASKA 99519-0708 TELE[~HO~E, 243.2455 Customer's ~ Order No. ~ ~-,, Date ALL Claims~ PAST DUE ~ bill MONTH. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW920050 DESIGN ENGINEER:S & S ENGINEERS OWNER NAME:LOUDON ZETHINA L 50% & OWNER ADDRESS:14250 SABINE ST ANCHORAGE, ALASKA 99511-2313 DATE ISSUED: 4/06/92 EXPIRATION DATE: 4/06/93 PARCEL ID:01819205 LEGAL DESCRIPTION: T12N R3W SEC 33 LT 45B 1 LOT SIZE: 45015 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS Tom Fink, Mayor N unicipality ,Ar chorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 April 6, 1992 Roger A. Shafer, P. E. S & S Engineering 17034 Eagle River Loop Road Suite 204 Eagle River, Alaska 99577 Subject: Waiver Request for T12N R3W Section 33 Lot Waiver Request #WR920013, PID %018-192-05, 45B SW920050 Dear Mr. Shafer: Your request for waiver of the required 100 foot horizontal separation of a septic system to a private well has been approved. The approved separation distance is 70 feet from the septic tank to the well. This waiver approval applies to the existing septic system to well separation only. Any future upgrade to either will require all separation distances be met or another approval from this department. Sincerely, Daniel J. Roth Civil Engineer On-site Services Program Ma g . On-site Services ljm: ~6 D~PT. O~ ENViRONM~NTAL CONSERV~TiON ANCHORAGE DISTRICT OFFICE 800 E. DIMOND BLVD., SUITE 3-470 ANCHORAGE, ALASKA 99515 WALTER J. HICKEL, GOVERNOR (907) 349-7755 April 6, 1992 Roger d. Shafer, P.E. S & S Engineering 17034 Eagle River Loop, Suite 204 Eagle River, Alaska 99577 Subject: Lot 45B; Section 33, T.12N., R.3W., Anchorage, Alaska, Waiver Request, ADEC Project Number 9221-WV-001; Waiver Approval Dear Mr. Shafer: This letter is in response to your submittal dated March 3, 1992 and received on March 9, 1992 requesting a waiver for a single family, 1000 gallon septic tank, to be located 95 feet from a Class C well located on Lot 45 C-1, and 70 feet from the single family well on Lot 45 B. The Department is granting the waiver as requested provided the following conditions are adhered to: 1) 2) The septic tank shall be constructed of 10 gauge rnetal and cathodically protected. All joints within the normal protective radii of the two subject wells shall be of watertight de_.~ 4) Engineered As-built plans shall be submitted upon completion of installation with a statement by the engineer verifying the system to be water tight, The Department also recommends that the septic tank be fully insulated to increase the overall ambient operating temperature within the tank, A higher operating temperature is more conducive to anaerobic decomposition of so:is and could result is lower volumes of solids being generated. Roger Shafer 2 April 6, 1992 This waiver is valid for installations occurring within two years of the above date. If you should have any question, please do not hesitate to contact me. Sincerely, Bill H. Lamoreaux, P.E. Anchorage District Manager BHL/cf cc: Dan Roth, DHHS Doug Robbins ~ ~U T3 2.7 March 19, 1992 ROBERTSHAFER, PF RQGERSHAFER. P.E CIVIL ENGINEERS (907) 694 2979 FAX t-~94 !211 HEALTH AUTHORITY APPROVALS SEWER & WATER MAIN EXTENSLONS SEWER & WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & Ft OW TEST SITE PLANS ROAD OESIGN SO~t TEST PERCOLATION TEST STRUCTURAL& MECHANICAL INSPECTIONS Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 L Street P.O. Box 196650 Anchorage, Alaska 99519-6650 REFERENCE: Lot 45B, Sec. 33, T12N, R3W, S.M. Request you issue a permit to i~tall a septic system and grant a waiver for the horizontal separat~on distance between a private well located on the referenced property and the proposed septic tank at a distance of 70 ft. As can be seen in the attached letter to the Alaska Deparlment of Environmental Conservation (DEC) we originally applied to the DEC for the referenced waiver. However, during a meeting at DEC on the referenced property on March 16, 1992 we were informed the review and approval of the separation distance waiver to the private w~ mu~t come from your office. Listed in the March 3, 1992 letter to the DEC are mitigating factors to justify the requested waiver. Also attached for your review is a recently perforated flow test for the private well. Water samples taken from the private well by a realtor involved in the recent sale of the property show neither nitrates nor colifo~ bacteria within the well water. We have collected our own water s~pl~s from the well on March 17, 1992 to ensure an appropriate third party sampling. These s~ple result~ w~l be forwarded to your office as soon as they are complete. As a result of the March 16, 1992 meeting at D~C we have added specific co~truction requirements to the proposed septic tank. These requirements include: I. The septic tank sha~ be completely sealed and constructed of 10 gauge steel. The tank shal~ have cathodic protection on both ends. 2. All pipe connectio~ w~l be a Romex type or equivale~. 3. The tank will be bedded and backfilled with a ~lean sand to within one foot from the surface of the ground. The engineer will verify that any portion~ of the protective coating that have been ac~dent~y removed from the tank are repaired prior to backfi~ng. ON SITE WASTE WATER DISPOSAL SYSTEM OESIGN 17034 EAGLE RIVER LOOP, SUITE 204, EAGt_E RIVER, ALASKA 99577 I" = 40' UPGRADE SCALE VACANT SABINE STREET N, T.S. PROFILE SCALE ~EWER ROCK Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L' Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION 'fES'r 1 2 3 4 5 6 7 8 9 10 DATE PERFORk ¥ownship, Range, Section:"~l'~.l~ '~--~.~, - SLOPE ~ SITE~ PLAN WAS GROUND WATER ENCOUNTERED? 11 12 13 14 15 16 17 18 19- 20- IF YES, AT WHAT DEPTH? Depth Io Water A~JJ?~._~ [ Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE ~ (m~nutos/~nch) PERC HOLE DIAMETER TEST RUN BETWEEN ~__FTAND_ ? FT 5 & S ENGINEEEtNG PERFORMED BY; ]7034 Eagle RiYer Loop ~Oa~ ~0, '~{~ ~ CERTIFY 'fHA7 THIS TEST WAS PERFORMED IN Eagle l~iver, Alaska 9¢577 ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~~ 72 008 (Rev 4/85) LOCATION OF WELL (Legal Description): w~ ~'r.: ~ ~_~. DATE DRILLING COMPLETED: ~ ~ ~ STATIC WATER LEVEL (Top of Casing): . ROBERTA, SHAFER CIVIL ENGINEER 694-2979 ~CL~ '4~ F"'r. DRILLER: FT. DATE: DATE OF TEST: __"~- ~"] ~"~'"~' SCREEN: CLOCK ELAPSED TIME SINCE DEPTH TO DRAWDOWNI PUMPING TIME PUMPING STARTED/ WATER, FT. RECOVERY RATE, GPM REMARKS STOPPED, MIN. V, :~ ~ ~ o ~, (sw~) o o sra, i,.4d~r-~--l~ .~r ~'~ 5 ~', ~' _. ~ ~ ~, 15 20 ,..~ ~ ~ 25 ~ ~' ~' ;~, ~ 30 40 ~4~ 45 ~' ~ a~.~ 50 55 ~'. ~ [ 60 (1 hour) ~ ~' ~' ~, O ~',~t 150 ~' ~ ~. I ~'. ~ t ~ao ~3 hours) ~ ~ ~ -~9, ~ ~t~ 240 (4 hours) t ~ ~ ~, ~ .~cow.v ~~/ ~',o~ t 0 ~ ~ O 0 .. ~'-~ ~ q~,' . ~1' ~ ~5 20 30 Comments: Is not Guarattteed §ubiequent Var|ation{ Can Occur. CHEMICAL o c~ GEOLOGICAL LABORATORY A DIVISION OF COMMERCIAL TESTING & ENGINEERING CO. TELEPHONE (907) 562-2343 5633 8 Street Anchorage, Alaska 995t8 Drinking Water Analysis Rvv~,rt, for -"'- v, . · TO BE COMPLETED BY ~,IAT:R ...... R [] PUBLIC WATER SYSTEM I.D. # ~'~PRIVATE WATER SYSTEM Z,¢C~o SANtPLE DATE: SAMPLE TYPE: Mo. Da), Year Routine Check Sample (for routine sample with lab rot. no, Special Purpose ~ Treated Water [] Untreated Water SAMPLE No. LOCATI(;)I~ , ~ 31 I 41 I Time Collected ~,,~C°llected~'-"/:~ ~//~ TO BE COMPLETED BY LABORATORY Analysis shows this Water SAMPLE to be; ',~ Satisfactory ~ Unsatisfaclory Ui Sample too long in transit; sample should not be over 30 hours old at examinalion to indicate reliable results. Please send new sample via special delivery mail, oete.e ived · rime ~eoe,ved Analytical Method: Membrane Filter ' No. of colonies,q00 mi. Lab Ret. No. Result* q2.O-Tm 2___ Analyst .E.C. ~C_ READ INSTRUCTIONS BEFORE BACTERIOLOGICAL WATER ANALYSIS RECORD Membrane Fliter: Direct Count Vorificallon: LSB Fecal Coliform Confirmation Corltorrrdl00 mi BGB COLLECTING SAMPLE Final Membrane Filter Results /1 TNTC = Too Numerous To Couni PART ONE OF T',Wtl: OB = Other Bacteria REMAINDER TO FOLLOW /¢- C3 a.m. CHEMICAL & GEOLOGICAL LABORATORY A DIVISION OF COMMERCIAL TESTING & ENGINEERING CO. 5633 B STREET ANCHORAGE. ALASKA 99518 TELEPHOHE(907) 562.2343 FAX 19071561-5301 ANALYSIS RESULTS for INVOICE J 51420 Cheraiab [~i ~ 92.67!7 Sac?lo J i },~rlx: WATER UA Client Acer FEB 2~ 92 ~ iS.~O XES BFO~ : FEB 2q 92 ~ iff:S? hrs. geqJ : AS REQUIRED Ordered By Anaiys~s Completed : ~'~g 26 92 Send Reports to: o .-r,xsor ~.~?,.~., C EEC I)HZRZOG, MARTIN :;IT?,ATE N %,: 13) P. 3, L E?A ~57,.2 1~ Sample ROUTINE SA~iPLE COLLECTED BY: MARTIN HERZOG, WITNESSED BI JEAN HERZOG. I Tests ?eriormed See Special ln~tructlona Above UA-Unavailable ND- None De~ected '" See Sample Re~ar~s Above MA- Not Analyzed LT-Loa$ Tbmn, GT-Crest~r Than ~-~ Member of the SGS Group (So¢i~t~ G~firalo de Surveillance) ROBERTSHAFER, PE ROGER SHAFER. P.E March 3, 1992 CIVIL ENGINEERS (907) 694-2979 FAX 694 1211 HEALTH AUTHORITY APPROVALS SEWER & WATER MAIN EXTENSIONS SEWER & WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAO DESIGN SOIL TEST PERCOLATION TEST STRUCTURAL& MECHANICAL INSPECTIONS State of Alaska DEPARTMENT OF ENVIRONMENTAL CONSERVATION 800 East Dimond Blvd., Suite 3-470 Anchorage, Alaska 99515 REFERENCE: Lot 45B; Sec. 33, T12N, R3W, S.M. Request you grant waivers for the horizont~ separation distances b~tween a proposed 1000 gallon septic tank and a Class 'C' w~ll located on the adjacent Lot CI, and a private well located on the referenced lot at 95 ft. and 70 ft. respectively. The septic syst~ serving the referenced property was recently abandoned to obtain approv~ on the Class 'C' well located on Lot CI. As can be seen from the attached site plan there is a steep slope on the property. To maintain a feasible pumping access to the proposed septic tank, the tank will need to be installed within the protective well rad~ as opposed to over the bank where the leachfi~ld is proposed. Mitigating factors to justify the requested lesser separation distance are as follows: O~y the septic tank will encroach the protective well radii. Generally, a septic tank is not considered a continuous source of effluent contamination as wou~d a leachfield. The proposed tank is to be installed with water tig~ couplings on the i~let, outlier, and both cteanout pipes. The recent soils test on the referenced property and the previously performed soils log on Lot 45CI show a medium soil permeability with a fair silt content. This should provide a high rate of effluent purification as the wastewater travels through the soil. Both soil logs did not d~tect groundwater. Th~£efore, the presence of groundwater should not hinder effluent treatment or aid in effluent migration. Although there is no w~ll log available for edther well, a flow test performed on the Class 'C' well in July 1991 shows a static water lev~ within the w~ll at 85 ft. below the ground surface. A Water Rights application for the Class 'C' w~, filled ou~ by a previous property owner, states the w~ ~ being 191 ft. deep. We presume both w~lls are similar in ON SITE WASTE WATER DISPOSAL SYSTEM DESIGN 17034 EAGLE RIVER LOOP, SUITE 204, EAGLE RIVER, ALASKA 99577 Pag~ Two Lot 45B; Sec. 33, TI2N, R3W, S.M. March 3, 5. 1992 The general too~raphy of the ar~a insinuates a sub-surface flow toward th~ west. Th~ means any effluent from the proposed septic syst~ wou~d probably travel away from the referenced wells. Therefore, we feel the separation distances prescribed under 18 AAC72 are not required in this case. With the issuance of these waivers we will apply to the Municipal Depar~nent of Health & Human Services for a permit to i~tall the septic system. This request is on behalf of our client, th~ current property owner: Martin H~rzog 3817 South Carson Street #428 Carson City, NV. 89701 (702) 885~0988 If you have any questions please contact me. Sincerely, ROGER J. F , P.E. RJS/~m or require additiona~ information for your revi~o, CHEMICAL & GEOLOGICAL LABORATORY A DIVISION OF COMMERCIAL TESTING & ENGINEI-'RING CO. 5633 B STREET ANCHORAGE, ALASKA 99518 TELEPHONE (907) 562-2343 FAX: {907) 561-5301 ANALYSIS RESUI, TS fez INVOICE i 51977 Chemlab ROE.# 92.1034 Sample ~ 3 ~atrix: WATEN Client Sample ID PWSID Collected DRINKING WATER L~SB SEC 33 T12N R3W SM Client Name :S & S ENGINEERING UA Client Acct :SNSENGP NAR 17 92 ~ 16:20 hts. BP0# : NAR 18 92 ~ 11:50 hrs. Roq~ : AS REQUIRED Ordered By :R. SNAFER PO~ :NONE RECEIVED Analysis Completed : NAR 19 92 Send RepoYt~ to: I, abo~atory Supervisor : STEPHEN C. EDE 1)S & S E)IGINEENING Reloa~od By : t/' ~._ ~/~ 2) Parameter Result, Units 14athod Allowable Limits UITRATE-N O.Ii mE/1 EPA 353.2 10 Sample ROUTINE SAMPLE COLLECTED BY: N.J.S. ND~ None Detected "Soo Sample Remarks AboYe NA- Not Analyzed LT-Less Than, GT~Oreate~ Than Member of tile SGS Group (Soci~tb G~n~,rale ds Surveillance) CItEMICAL & GEOLOGICAL LABORATORY A DIVISION OF COMMERCIAL TESTING & ENGINEERING CO. TELEPHONE (907) 562-2343 5633 B Street Anchorage, Alaska 99518 Drinking Water Analysis Report for Total Celiform Bacteria TO BE COMPLETED BY WATER SUPPLIER ~PRIVATE WATER SYSTEM S & S ENGINEERING 17034 Eagle River Loop Roa~ Mailing Addles~ Mo. Day SAMPLE TYPE: ~Routine [] Check Sample (for routine sample with lab ref. no. [] Special Purpose State Zip code Year [] Treated Water [] Untreated Water SAMPLE No, LOCATION 41 Time Collected Collocled By TO BE COMPLETED BY LABORATORY Analysis shows this Water SAMPLE to bo: ~' Satisfactory E] Unsatisfactory [] Sample too long in transit; sample should not be over 30 hours old at examination to indicate reliable results. Piease send new sample via special delivew mail. Analytical Method: Membrene Filter No. of colonies/100 mi. Lab Ref. No. ~2,1034 4 I Result* Analyst BEFORE COLLECTING SAMPLE READ INSTRUCTIONS Membrane Filter: Direct Count Veriflcstion: LSB I-'ecal Coliform Conflrmallon Final Membrane Filter ~ults BACTERIOLOGICAL WATER ANALYSIS RECORD TNTC = Too Numerous To Count OB = Other Bacteria BGB Date Coliformll00 mi Collform/100 mi PART ONE OF TWO REMAINDER TO FOLLOW • • • • QP _xe`, • _ Municipality of Anchorage owy,,,,,,,,‹"t�_�=-.?` On-Site Water and Wastewater Program < "milI•m (907) 343-7904 SA E. Certificate of On-Site Systems Approval Parcel I.D. 018-192-05 Expiration Date: 10 ---/ S -10 1. GENERAL INFORMATION: Complete legal description T12N, R3W,Section 33, Lot 45B Location (site address) 14250 Sabine Street*Anchorage,AK 99516 Current Property owner(s) Paget Plunk Day phone 687-5323 Mailing address Real Estate Agent Doug Rickel Day phone 240-2152 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual El Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance requ r: I Distance: Received by: Date: 3// //$ 1 COSA to be released tot e •ng er,unless otherwise requested by the engineer. COSA Fee $ Ace' .GD Waiver Fee $ Date of Payment 3(13(f$ Date of Payment Receipt Number Receipt Number COSA# (21C/71 0 PO Waiver# • 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road,Suite 101-Anchorage,Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: 3//2_,// 0000OO�� In conducting this evaluation,GEG provided an engineering evaluation of the well and/or septic system o0 OF A� 004 in accordance with the guidelines and regulations established by the Municipality of Anchorage and K\� .••......• . 4 ,6 industry practices. The reported results describe the condition of the system/s on the date/s of the 4 P • • Q evaluation. Separation distances were measured to readily identifiable features. Hidden defects or O� ��-) . d encroachments may exist that were not identified during the evaluation. The operational life of all wells �� .i 9 T and septic systems depend upon a variety of variables, including but not limited to, soil conditions, 0.. groundwater levels (that may fluctuate during the year), quality of construction (materials and 4 VA workmanship),and the water usage of the family utilizing the system/s. These conditions can vary,and Q. . . . - are outside the control of GEG. Satisfactory test results do not guarantee future performance of the Q '•,Je r-, •. Carnes..•• system/s;therefore, GEG makes no warranty(express or implied) regarding the future performance of On , E_ . Q� the well or septic system. GEG makes no representation whether an alternative well or septic system Q'9's • (d •,ce4 can be installed on the property in the event either of the current systems fail to perform adequately in C4 o •'2.r1�• •� ccO the future. The content of this report is for the sole benefit of the person/party that retained GEG to apet& rofessio perform the evaluation. Reliance upon the information provided in this report by any other person or �OOOo • party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. #AECC884 6. DSD SIGNATURE System #1 Approved for 3 bedrooms System #2 Approved for bedrooms Disapproved � �-�(� Dc'�iC,y �, o Conditional approval for bedrooms, with theAIlowboAp atior = WATER AND 'is m WASTEWATER - n PROGRAM SEPI\`-' By: v� –E Original Certificate Date: ^13 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: �t COSA Checklist /" Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet_10-10-12.doc If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: T12N, R3W, Section 33, Lot 45B Parcel ID: 018-192-05 A. WELL DATA Well type Private If A, B, or C provide PWSID# N/A Well Log (Y/N) Yes Date completed unk Sanitary seal (Y/N) Yes Wires properly protected (Y/N) Total depth 162 ft. Cased to unk ft. Casing height (above ground) 12+ in. FROM WELL LOG AT INSPECTION Date of test unk 1/16/2018 Static water level 100 ft, 43.1 ft_ Well production 12 g.p.m. 4.8+ g.p.m. WATER SAMPLE RESULTS: Coliform Ne9 colonies/100 ml. Nitrate 0.356 mg./L. Collected by: GEG. Ltd. Arsenic: <5 ug./L. Date of sample: 1/30/2018 k ( {3i /Zvl rd B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/HDPE Date installed 2/26-27/2018 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) Yes Foundation cleanout (Y/N) Yes Depression over tank (Y/N) No High water alarm (Y/N) N/A Date of pumping New Pumper C. ABSORPTION FIELD DATA 4/7-10/1992 0.6 Deep Trench Date installed 2/26-27/2018 Soil rating a.p.d./Ior ft'/bdrm) 0.6 System type Deep Trench 58 3 6.5 Length 55 ft. Width 2.5 ft. Gravel below pipe 7 ft. *11+ 754 Total depth **10.7+ ft. Eff. absorption area 770 ft2 Monitoring tube Yes Depression over field No Date of adequacy test New Results (Pass/Fail) Pass For 3 bedrooms Fluid depth in absorption field before test — in. Water added — gal. New depth — in. Elapsed Time: - min. Final fluid depth — in. Absorption rate >= 450+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N/A _ If yes, give date — *Below existing grade **Below final grade D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off" level at .. wa er alarm level at in. •- •• Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot *65'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main 75 + Public sewer manhole/cleanout 100'+ Sewer/septic service line 25'+ Holding tank 75'+ Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots *85'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain None Known Wells on adjacent lots 100'+ F. COMMENTS *WR#OSV181003 oo0 \.. _ G. ENGINEER'S CERTIFICATION o,�'> of A 4s�0 0I) I certify that I have determined through field inspections and 10 ` 9l H r '.Y VO review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this v _ ' date. J... ... ...� f = A. •ame .; Engineer's Printe Name JEFFREY A. GARNESS vA,/ CE 79 3 OO Date 3 /2.-// e �Q "�Pa'' 1.L1r,'�F,00 %z-,..,„. 00 P fesi000� D„Og��o #AECC884 (Rev. 11/05) LOT 45C1 LOT 45D1 f I i N 89 59' W 299.73 4 O o1 i ! U 4N1 W W 1 ZJ 9 ® SH O W N I j 3 0o t j z o o W I 1 oo Wg CC! O / ''''9,0 ts2 y W i Ne DF tic •11111 Z_ 0 oG< 1!!1 Z o s� CO! 'Q^! Z ox DECK ( ) • J- I DECK • • ! i N 89 59' W 299.74 ! z. 0� LOT 52 i 0"' v i AS-BUILT SURVEY 1 " = 30 ' NO CORNERS SET THIS DATE 0oo000p I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY v1;, OF '4 L OF THE FOLLOWING DESCRIBED PROPERTY Opl •..' ,..A., .CSS O�0 LOT 45B, SECTION 33, T 12 N, R 3 W, S.M. , PLAT 66-154 i9.:49 TH it 1t1 ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE 0. . �� ,�f ' 'Q VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN 0 Sht"..�� /i�G°- THE INFORM4TION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS 0/)7+ • '",f::' `� CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS; AND IS EXIST OTHER THAN NOTED. vs- SHANEA.HOLT .• i NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES. DATED AT ANCHORAGE,ALASKA THIS 6 TH DAY OF Q4 P LS-6914 O� EASEMENTS OF RECORD, OTHER THAN THOSE APPEARING ON THE RECORD PLAT , ARE NOT SHOWN 2018 1411'V 4 0 •.• y p HEREON ( UNLESS INDICATED) MARCH , 04p�O.e, i°naA�6c PROPERTYTE: ELINES OR POSITELINES THAT ION ADDITIONALTHIS IMPROVEMENTS ARE NOT TO BE USED TO DETERMNE �p000o� ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE. HOLT LAN) SURVEYING 1304 GROVER DRIVE ANCHORAGE,AK 14507 13311, FB 187-1, RTK FILE,13811 RC 3-I-5513 Parcel I.D. # MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING HAA # ~UNICIPALI~, AUG 04 GENERAL INFORMATION Complete legal description Location (site address or directions) Property owner Mailing address Lending agency Mailing address Agent Address Dayphone ~2.- ~1~1 Day phone Day phone Unless otherwise requested, HAA will be held for pickup. ,,2_. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: NOTE: Individual on-site Holding tank Community on-site Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72K)25 (Rev 1191) Front MOA ~21 STATEMENT OF INSPECTION BY ENGINEER. As certified by' my seal affixed hereto and as of'the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Munic!pal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm ~ - Address .. r-~-¢ Engineer's signature Phone DHHS SIGNATURE Approved for -~- Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DH HS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev, 1/91) Back MOA ¢Y21 DEPARTMENT OF HEALTH & HUMAN SERVICES Environmental Services Division 825 L Street, Room 502. Anchorage, Alaska 99501· (907) 343-4~ Health Authority Approval Checklist Legal Description: Parcell. D.: ¢1~- l~/'2.-~ d)~ A. WELL DATA Well type ,,"-'~' Log present (Y/N) ~' Total depth [~'~ Sanitary seal (Y/N) Date completed . Cased to I~ .'2. / If A, B, or C, attach ADEC letter, ADEC water system number _ Cas ng le ght (above ground) Wires properly prote~ted (Y/N) Dote of test Static water level Well production FROM WELL LOG AT INSPECTION g,p,m, WATER SAMPLE RESULTS: Coliform ¢ Date of sample: 'TIilI~I/CJ~I Nitrate ~ ~, /~"~//~C Other bacteria Collected by: J,1, -~, SEPTIC/HOLDING TANK DATA Date installed Z~10"¢~;2-- Tank size j~,~) Number of Compartments ~ Cleanouts (Y/N) Foundation cleanout (Y/N) y Depression (Y/N) J~ High water alarm (Y/N) Date of Pumping ~::¢/~_/'¢'~ _Pumper C. ABSORPTION FIELD DATA Date installed /¢ I/P .-ct % Length. ~-,~ Width Soil rating (g.p.d./fF or4¢/b~rn) ~ ;~, System type Gravel thickness below pipe ~¢,~' Total depth Effective absorption area '-~ ~ Monitoring Tube present (Y/N) _ Depression over field (Y/N) . _ Date of adequacy test 7.~. ~ ~ Results (Pass/Fail) '"~ For ~-- Fluid depth in absorption field before test (in.); Fluid depth ¢ / (ins) Minutes later: Peroxide treatment (past 12 months) (Y/N) bedrooms Immediately after~r_~gel, water added (in.): _ ~ ~/~. Absorption rate = /¢/~ 7 g,p.d. If yes, give date 72-026 (Rev. 3/96)* D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at* High water alarm level at* ~ .... *Datum Cycles tested ~ "Pump off" level at* E, SEPARATION DISTANCES SEPARATION D STANCES FROM WELL ON LOT TO: Septic/holding tank on lot "'/¢ I Absorption field on lot Public sewer main '~,'///~- Sewer/septic service line ~ ,~-.~ On adjacent lots On adjacent lots sewer manhole/cleanout Public Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Foundation .~'~ Property line ) 1,OI Absorption field /_.dO" Water main/service line ?~5" Surface wateddrainage ~] u) Wells on adjacent Pets SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO: .~¢ ?~' Building foundation ~/~t Property line Surface water Curtain drain Water main/service line Driveway, parking/vehicle storage area Wells on adjacent lots I ~)~ / F. ENGINEER'S CERTIFICATION I certify that I have determined thru field inspections and review of Municipal records that the above .s, ystems are in conformance with MOA HAA guidelines in effect on this date. Signature ~.~ Date ~ L/I Iff ~ HAA Fee $ ~ ¢ ~ Receipt .mber 72-026 (Rev. 3/96)* Waiver Fee $ Date of Payment Receipt Number