Loading...
HomeMy WebLinkAboutT12N R3W SEC 33 LT 52 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP221363 PID Number: 018-192-17 Page 1 of 3 Dwelling: M Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: n New n L)nnrarla Name y MARY & EIVIN BRUDIE ABSORPTION FIELD I SOUTH/NORTH ❑ Deep Trench ❑® Wide Trench ❑ Bed ❑ Mound Site Address 14320 SABINE STREET *ANCHORAGE, AK ❑ Other Phone Tmber of Bedrooms 907-240-0135 Soil Rating Total depth from original grade 0.8 GPD/SF 8.7/8.07 AAAYI Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe SEE DWG. Ft. 4/4 Ft. Subdivision Block Lot 52 Fill added above original grad SEE DWG. M?1? Gravel length Township Range Section T12N R3W 33 II �' Ft.42/43 Ft. Gravel width 5� Beds: Number of Lines - Distance between lines SEPARATION DISTANCES To Septic Absorption Holding Sewe7 Tank Lift Station Field From Tank __ Ft. Total absorptio area Number of trenches - Ft. Dist. between trenches Lind SS—C' ` W 2 $+ Ft. Well 100'+ 100'+ 100'+ - 25'+ AN El3S is [9 S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity Surface Water 100,+ 100,+ 100,+ - GREER TANK 1500 Gal. Material Number of compartments Lot Line 5'+ 10'+ 5'+ - NA PLASTIC 2 Foundation 10,+ 10'+ 10'+ - LIFT STATION Manufacturer Capacity Remarks OLD TANK DECOMMISSIONED PER UPC PER CONRACTOR GREER TANK 500 Gal. Alarm location Electrical installed by I n Wnf Installer PIPE MATERIA House to tank D3034 Tank to D 1785 drainfield GLW Drainfield D3034 CO/MT D3034 Inspector GEG AND MOA BENCH MARK (Assumed elevation) 100.00 ft Inspectiones: 1s' 10/19/22 2�a 10/24/22 Location and description 3- 10/24/22 4- 10/25/22 GARAGE SLAB B ON -SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date oo6�Op�� o ��.•••"• � H .70 0 .. .............................. { Septic System Approved O .Je je* AGa . rness.: 09. AG-795 �QD 00E Date r I zo zoz 4pfe� t 1� Note: this approval does not include well permit requirements. Qea i �� o p p�°fessi°n°o� ��0`�p0o� (Rev 05/02/1A) #AECC884 VISTA tt/27lz3 ERMIT NUMBER: POSP221363 RECORD D RAW I N G PARCEL ID NUMBER: 018-192-17 A I B DBL1 47.6 53.6 DBL2 47.7 53.9 MH1 47.3 54.2 MH2 47.6 56.4 C01 69.8 79.0 MTi 68.9 78.1 CO2 79.3 75.1 MT2 80.3 76.0 z CO3 91.9 w I MT3 NLUC04 91.4 MT4 92.44 NOTE: PIPE LOCATIONS ARE H SHOWN PER GEG SHOTS o TAKEN WITH LEICA DISTO S910 LASER DISTANCE I METER. SWING -TIES TO HOUSE CORNERS WERE I GENERATED IN AUTOCAD. MT ICO F C O MT CONVERTED TO 4" PRIOR TO FLOW SPLITTER D3034 10' �. NEW 1500 GALLON HOPE GREER TANK, USED AS STEP TANK— I IT IS REPORTED THAT THERE IS AN FCO INSIDE THE HOUSE IN THE BASEMENT SHOWER DRAINFIELD �02 2 ♦♦ 7.H.#1 / ,DBL1,h(2 / EXISTING 4 BEDROOM HOUSE DRIVEWAY EXACT LOCATION OF EXISTING SEWER LINE IS UNKNOWN. SEWER LINE AND WELL WERE INSTALLED PRE-1982 AND THERE WAS NO SEPARATION DISTANCE REQUIRED AT THAT TIME i fit EE ING GRO" U P, Ltd ENGINEERING SALES* NSUMNfi 3701 E. TUDOR ROAD, SUITE 101 -ANCHORAGE, AK 99607 -PHONE (907) 337E179 -PAX (907) 336.3246 ` WEBSITE: w .games gineering.wm PREPARED FOR: PHONE NUMBER: PAGE NUMBER: MARY AND EIVIN BRUDIE 907-240-0135 2 OF 3 LEGAL DESCRIPTION: DRAWN BY: T12N R3W SECTION 33 LOT 52 D.J.G. TYPE OF WORK: DATE: SEPTIC SYSTEM RECORD DRAWINGS 11/29/2022 'E;,�.. Ni, AV c,' �1 .�.,...4 .................... .'; ;�.. Oka.... ......... .; #♦� CE- 953 .� �! � ,.•�' i LICENSE ft. M\\�\�+►• #AECC884 J PERMIT NUMBER: RECORD D RAW I N G PARCEL ID NUMBER: OSP221363 018-192-17 TOP 01 INVERT OF I ORIGINAL GRADE AT HIGHEST POINT = 103.09 T.H. #1 NEW 1500 GREER TANK WITH ANCHORAGE TANK COMPONENTS TO BE USED AS LIFT STATION NORTH SOUTH T 4.0' T RELATIVE ELEVATION OF BOTTOM OF T.H. = 87.09 (DRY) ).M 1.87-99.99 cT = 91.35 FINAL GRADE = 103.17-103.35 ILT O FINAL GRADE = 103.03-103.51 ORIGINAL GRADE AT HIGHEST POINT = 103.75 r FILTER FABRIC 1 T.H. #1 TER FABRIC INVERT OF PIPE = 99.03 INVERT OF PIPE = 99.05 BOTTOM OF TRENCH = 95.02 S—` I BOTTOM OF TRENCH = 95.05 8'+ RELATIVE ELEVATION OF BOTTOM OF T.H. = 87.75 (DRY) AV 4 a ................ ..... .. - ENGINEERINGoSALES* CONSULTING 3701 E. TUDOR ROAD SUITE 101 'ANCHORAGE, AK 99507 -PHONE (907) 337-6179 • FAX (907) 33&3246' WES&TE: wv. v.garneeeengneenN,. ............ ....... • 0 PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ••••• f ~ MARY & EIVIN BRUDIE 907-240-0135 3 OF 3 `j :'. a' re AV LEGAL DESCRIPTION: DRAWN BY: #� �Y(�•••.• 1•. �E-79153amess •% ` T12N R3W SECTION 33 LOT 52 D.J.G. �,'• �� ;� . P ♦��► TYPE OF WORK: DATE: SE � SEPTIC TANK PROFILE 11/29/2022 LICE 84v, lkik"** LW 0 0 O Oi CA w m (A G.W O 0 r r\ S 89'58'33" E 329.71 ' T r ron-t. Se -back f i no 1 a ,U1 v) Septic Shed Q- Field WOW 17' x 12' '.�. I ®C 0 C.O. n i Septic Ta n k o /Lids —1b j 67.3 a c S 89'59'27" E 329.66' House 1 i t I I I �u 4 Gravel 1 c, z Driveway (T)w a w W a L 52 I^ Building Detail Paved 24.0' Entry 4%. o Deck -a 8.0 0 20` 5 �O O I , r, r, Deck 45.1 NOTES I Basement Window Egress' 1. Bearings and distances are record per referenced plat unless otherwise noted. 2. Sufficient boundary evidence was recovered to establish the subject parcel on the ground. Not all controlling evidence is shown hereon. J OF At;q tl 49TH .. Robert 0. Lumpkin : Q �i•- No.10459 �A' farpoint Land Services, LLC LEGEND SURVEYING, MAPPING, LAND PLANNING, GIS Rebar !iarpoin Monument 1 13 1 E. 7Gth Ave., 5uite 101 Anchorage, Alaska 995 18 n Septic Vent FtAK.com • (907) 522-7770 • survey@farpointak.com ILc-O ASBUT SURVEY OF: SURVEY CERTIFICATION: FARPOINT has conducted a physical Power pole T12N R3W Sec 33 Lot 52, survey of the subject property, the improvements situated O Septic Lid Anchorage, Alaska thereon are within the property lines as shown. EXCLUSION NOTES: It is the owners responsibility to PREPARED FOR: determine the existence of any easements, covenants, or restrictions which do not appear on the Plat used for this Eric Brudie 14320 Sabine St WORK ORDER No DATE: NOV 10, 2022 SCALE: ' — 1 '-60 ZONING: R6 22121 � � 1 survey. NOTE: Under no circumstances should any data hereon be used for construction or for the establishing of Anchorage, AK 99516 DRAWN: CHECKED: GRID No: FB BOOK/PAGE: CB ME SW3034 164/12 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221363, Curtis Townsend, 09/27/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221363, Curtis Townsend, 09/27/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221363, Curtis Townsend, 09/27/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221363, Curtis Townsend, 09/27/22 GR[ ':R ANCHORAGE AREA BOP IGH Department of Environment quality 3500 Tudor Road Anchorage, Alaska 99507 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME f///'/ ~ ~-¢?'~ _ MAILING ADDRESS~./ ,~/-2,X'~z-/ PHONF LOCATION--~¢-~'--'¢'~'/~/~'"~/¢'-;/~/~'//// LEGAL DESCRIPTION /~//~'_~'~.~ ...C¢~:~, ..-~g.~ SEPTIC TANK: DISTANCE ~/~-' NUMBER OF / FROM WELL ~' ~ ' MANUFACTURER,~2ZP~///~'/~/Z)-¢J'' MATERIAL ~--~/~ __COMPARTMENTS INSIDE LENGTH '-- iNSIDE WIDTH ~ LIQUID DEPTH ---' LIQUID CAPACITY~C~/,{~GALLONS. TILE DRAIN FIELD: ~ / /~/~¢ TOTAL LENGTH DISTANCE FROM WELL ~ FOUNDATION ~/ NEAREST LOT LINE~~/~ OF LINES NUMBER OF LINES DISTANCE BETWEEN LINES ~ '~ TRENCH WIDTHS/ IN. TOTAL EFFECTIVE ABSORPTION AREA SQ. FT. LENGTH OF EACH LINE ~~~ / DEPTH OF FILTER DEPTH: TOP OF TILE TO FINISH GRADE/~ ' ' / ~ IN. ~/~MATERIAL BENEATH TILE ~ _IN. ABOVE TILE WELL: TYPE ~,~E' /~-~'~-~.~ CONSTRUETION_ ' ~",/Z~/~'~'~] ___DEPTH ,¢-/~t'/-~¢ DISTANCE FROM: BUILDING F 0 U N D A T I 0 N~,~,~,~,~,~,~,~,~,~¢ NEAR LOT LINE~-/¢~'J~' , NEAREST SEWER LINE SEPTIC x SEEPAGE TANK ~'~/'/ , SYSTEM CESSPOOL./_~'¢>'/~:~ , OTHER SOU RCES t/P/~ /C"/J/~/~-¢~/ APPROVED DISAPPROVED I N ST A L L E D B V: ~'A'~/) ~/~'¢¢2Z)'¢-~' SEWER LINE DEPTH: PIPE MATERIAL: DIAGRAM OF SYSTEM LOT SLOPE: REMARKS: G.A.A.B. Form PW-027 SEWAGE DISPOSAL SYSTEM --~ APPI_ICA!F~ON AIND PEftMFF 5 fi:. zl 9,9 1'1 Fi'ED WITH AI~ITIGIIT REMOVABLH CAPS. ~ATEP A!ICHQRAGE AP, /~ BOROt DEPAP, IHE¢Ii' OF £iiV[ROFi[!Ehi;\L OUAt. ii' 350Q TUDOR ROAD A:ICtlORAGE, ALASKA 99502 Performed For~ ¢~td~- Leqal Descrintion: kot~_Block____ This Form Remorts Soils Loq X Bate P e Y 'f o r rn e d _y/_2~/~]~_ Subdivision Seo 33 T ~N R 3 X. Percolation Test Deoth Feet Soil Characteristics SM si3;by sands (~0) Was Ground Water Encountered?___mo_ I¢ Yes, At what Denth? F Readinq Date Grnss Tinle Net Time Benth to 1120 Net Drop Fercolation Rate r!inute Proposed Installation: Senr~aae Pit__ ~ ..... Drain Field .... Demth of Inlet Oenkh To Roi:tom ~F Pit Or Trench Pa~e: MUNICIPALITY OF ANCHORAGE i; Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Z 2 2 G Parcel I.D. 018-192-17 Expiration Date: Legal description T12N R3W SEC 33 LT 52 Site address 14320 SABINE ST Anchorage AK Current property owner(s) MARVIN X The On -site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: By: L_ Original Certificate Date: 11 /20/2023 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal. code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory _ Absorption Field Advisory Nitrate Advisory X Tank Age Advisory Arsenic Advisory _ Other COSA ApprovaUune 2022 MUHMPAUTY OF ANch' ORAGE Development Services Department A Phone: 907-34.3-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 018-192-17 Complete legal description T12N R3W SECTION 33 LOT 52 Location (site address) 14320 SABINE STREET *ANCHORAGE, AK Current property owner(s) MARY & E I V I N B R U D I E 2. ON -SITE SYSTEMS SIZED FOR 4 BEDROOMS Day phone 907-240-0135 3. TYPE OF WATER SUPPLY: M Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: 0 Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel n Plastic ❑ Concrete ❑ Fiberglass Age NEW - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench 0 Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee $ 7ij�d Waiver Fee $ Date of Payment 11 / � / - U -Z COSA# OSc,Z3i/Y.34-- Date of Payment Waiver # COSA Application —June 2022 COSA Checklist Legal Description: T12N R3W SECTION 33 LOT 52 Parcel ID: 018-192-17 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled `58/59? Total depth *`104.6+ ft Cased to LINK ft 0 Sanitary seal is functioning correctly X Wires are properly protected Casing height (above ground) 12+ in Date of flow test for COSA 8/24/22 Well production at time of test 7.3+ gpm Water storage tank volume N/A gallons Well -disinfected for coliform test? ❑ Yes N No INI Coliform bacteria Nitrate 3.78//�ma a/L Arsenic ug/L Collected by GEG Static water level at beginning of test 98 8 ft. ate 8/3/22 6o It 40 23 Comments *PER PREVIOUS COSA **PER GEG WELL TEST B. TANK DATA Measured operating fluid level in septic tank NEW Date of pumping N/A ❑ Required maintenance completed, if AWWTS Comments: NEW INSTALL - RECORD DRAWINGS ATTACHED D. ABSORPTION FIELD DATA NORTH/SOUTH Which system tested (date installed) 2022 R ALL standpipes present per record drawing Total measured depth from grade 8.3/8.5 ft (max) Measured depth to pipe invert from grade 4.14/3.98 ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. 0 Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced - gallons - date Any rejuvenation treatment (past 12 months) - If yes, enter date - Comments/Deficiencies: Negative ❑ Nitrate less than MRL (ND) *A, rsenic less than MRL (ND) C. LIFT STATION 0 Required maintenance completed Age of lift station NEW years Lift station material PLASTIC Comments: Adequacy test date N/A Results Q Pass Fluid depth prior to test - in Water added - gal New fluid depth - in Elapsed time - min Final fluid depth - in Absorption rate 600+ gpd FIELD STATUS — POST RECOVERY Effective depth (per record drawings) 48 in Effective depth used 0 in Effective depth remaining 48 in COSA Checklist June 2022 E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanout > 100' DYes if No ft M Yes if No ft Neighboring Tank > 100' ❑i Yes if No ft Private Sewer/Septic Line > 25' ❑ Yes if No *LINK ft Absorption Field on Lot > 100' E Yes if No ft Holding Tank > 100' RYes if No ft Neighboring Absorption Fields > 100' Animal Containment > 50' R Yes if No ft ❑i Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' MN Yes if No ft Q Yes if No ft ❑ N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' Q Yes if No ft Surface Water > 100' Q Yes if No ft Tank to Property Line > 5' Fil Yes if No ft Wells on Adjacent Lots: Field to Property Line > 10' Q Yes if No ft Private Wells > 100' 0 Yes if No ft Water Main > 10' no Yes if No ft Community Wells > 200' 0 Yes if No ft Water Service Line > 10' M Yes if No ft If tank or field is under driveway comment below F. ENGINEER'S COMMENTS *SEE RECORD DRAWINGS - EXACT LOCATION IS UNKNOWN G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on -site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Garness Engineering Group, LTD. (GEG) Phone 907-337-6179 Engineer's Printed Name Jeffrey A. Garness Date In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend upon a variety of variables, including (but not limited to) soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding', the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail to perform adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG . to perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. 0 acs E `a COSA Checklist June 2022 —Nitrate Advisory Certificate of On -Site Systems Approval # OSC231435 Subdivision: T12N R3W SEC 33 LT 52, Block: --, Lot: --- A water sample revealed a nitrate concentration of 5.34 milligrams per liter (mg/L). The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Since nitrates are known to slowly increase, we recommend you monitor the water quality. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. Mailing Address P J OBpx 196650 Anchorage,'Alaska 99519 6650 * www muni org r From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. Mailing Address P O Box 196650 *Anchorage, Alaska 99519 6650 *tiwww muni org MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTEC'I'ION DIVISION OF ENVIRONMENTAl_ HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date GENERAL INFORMATION (a) (b) (c) Legal Description (include lot, block, subdivision, section, township, range) Location (address or directions) Applicant Name /~-:~: t/:-/~' ,,~/~'(?,?2.¥~ Telepbone: Home 8usinoss Applicant Address Applicant is (check one): Lending Institution []; Owner/builder I'q; Buyer[~; Other [] (expLain); (d) (e) Real Estate Company and Agent Address ~z~,/~¢ Telephone , (f) Mail the HAA to the following address: TYPE OF RESIDENCE Single-Family'[~]/ Multi-Family [] Other N.mber of-Bedrooms WATER SUPPLY Individual Wel Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. SEWAGE DISPOSAL Onsit(~[~ Pubtic [] Community [] Holding Tank [] Note'. If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA Ar,iD INFORMATION As cedified by my seal affixed I~ereto and as of the validation date shown below, I verify that my i nvestigatiou of this Healtl~ Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Munioipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance witi~ all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Approved for~_ bedrooms b~;~~~c~ ~ Date _~/~//~..~', Approved ~ Disapproved Conditioi~al'~ Terms of Conditional Approval CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based sorely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does tills as a courtesy to purchasers of homes and their ]ending institutions in order to satisfy certain lederal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued, The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72~025 (11/84) M~NIC[PALITY OF ANCHORAG~ DEPT. OF HEA~TH & ~NV[RONM~N~A~ pRO~ECTION 2 2 986 WELLDJ cEIVE MUNICIPALITY OF ANCHORAGE (MOAi HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 264-4720 Legal Description: ~-(P/ '~"/-::/ '- If A, B, C, D.E.C. Approved (Y/N) Well Classification ~//_~;:[/×~; ?2L: , / Well Log Present (Y/N) /~'~"~ ~o/., Date Completed Yield TotalDepth ('[i~" "/~ Casedto / [_~' ¢- Depth of Grout,ng Static Water Level Casing Height Above Ground //~<~ '~' Electrical Wiring in Conduit (Y/N) Separation Distances from Well: ' To Septic/Holding Tank on Lot __ To Nearest Edge of Absorption Field on Lot Pump Set At Sanitary Seal on Casing (Y/N) ~ Depression Around Wellhead (Y/N) //F/ To Nearest Public Sewer Line Cleanout/Manhole __ Water Sample Collected by Water Sample Test Results Comments ; On Adjoining Lots ; On Adjoining Lots "/?'~ ~ To Nearest Public Sewer To Nearest Sewer Service Line on Lot .,/r'~7 ."' ' .., SEPTIC/HOLDING TANK'XDATA ~/'~ ~-'~ '; .~ Date Installed ~,~~ize ~_~c/ No. of Compartments "~ Standpipes (Y/N) _ I ~/ ' Air-tight Caps (Y/N) /V Foundation Cleanout (Y/N) Depression over Tank (Y/N) Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) ~//;'/ Separation Distances trom Septic/H, oldin9 Tank: To Water-Supp y We TO Property Line r~ k"" TO Water Main/Service Line Oate Last Pumped -:' :'/~ ; for Temporary Holding Tank Permit (Y/N) To Building Foundation To Disposal Field To Stream, Pond, Lake, or Major Drainage Course Comments Page 1 of 2 72-026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata ~V~'~'~' Date Installed ~ ? '-' Width of Field _ ,--4'?/ Square Feet of Absorption Area Depression over Field (Y/N) Type of System Design~ Length of Field .~', ~ Depth of Field ./~72 ~ ¢ Gravel Bed Thickness -~¢~ '" Standpipes Present (Y/N) Date of Last Adequacy Test // Results of Last Adequacy Test Separation Distance from Absorption Field: To Water-Supply Well //¢~--~ (~ - To Building Foundation Lot To Water Main/Service Line To Stream/Pond/Lake/or Major Drainage Coursa To Driveway, ~arking Area, or Vehicle Storage Area To Property Line To Existing or Abandoned System on ; On Adjoining Lots To Cutbank (if present) ,/(/ /// Comments D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Dimensions Manhole/Access (Y/N) "Pump Oft" Level at Vent (Y/N) Pumping Cycles during Adequacy Test, Meets MOA Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify thai I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed Date Company MOA No. Receipt No. ~ ~' ~¢' ?,~ ..2_. Date of Payment %-~-~- ~"1'-'~--~, ,~'-~? 2~-o0 ~ Amount: $ '<%~ -¢"-"~ ~ ¢-~- ~"~' ~ Page 2 of 2 72-026 ( 11/841 _~ Datum Engineering_ & Surveying, Inc. (907) 563-3 ~ 42 4500 Business Pc~rk Blvd. Doturn Building Anchorage, Alaska 99503 June 11, 1986 Mr. Elvln Brudie 14320 Sabine Street Anchorage, AK 99516 RE: Adequacy Testing on Existing Sanitary Sewer System Lot 52, Section 33, T12N, S.M, Alaska Dear Brudte: On June 10, 1986, DAllJM ENGINEERING & SURVEYING, INC., performed an adequacy test on your system. A total of 1,810 gallons of water was introduced into the primary compartment of the existing 2,000 gallon tank. Water was injected over a 345 minute period. The average injection rate was 5.2 gallons per minute,. The distance between the top of the standpipe and the top of the measuring rod was 35-1/2 inches at the beginning and remained constant throughout the duration of the test. The house is currently occupied and therefore the system is at it's normal degree of saturation. Based on a six (6) bedroom house at 150 gallons per day per bedroom, the daily design flow should be 900 gallons per day. DATIJN ENGINEERING & SURVEYING, INC., injected 1,810 gallons of water with no rise in the septic system; therefore, we may conclude that the system is adequate. If you have any questions or require additional services, please call. Sincerely, Bruce D, Patterson, P,E. Principal BDP/cc ~:IF.. 1:1'7 II ti II II II /:37 /: '-/?. 1: ~t'7 II ~TY OF kA~CJ-IORAG~ MUNICIPALITY OF ANCHORAGE DEPT. DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTEDTIO~NviRONM[i,q,~/\L 825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL ENGINEERING DIVISION Telephone 264-4720 DIRECTIONS: Complete all parts on page 1, Incomplete requests will not be processed, Please allow ton (10) days for processing, 1, PROPERTY OWNER . PHONE Eivin/Mary Brudie 344-2261 MAILING ADDRESS 726 K Street 99501 279-6535 PHONE PROPERTY RESIDENT (If different from above) ~ BUYER ~ PHONE MAILING ADDRESS 3, LENDING INSTITUTION Alaska Pacific Bank PHONE 274-9661 MAILING ADDRESS Post Office Box 420 99510 4. REALTOR/AGENT {~HONE MAILING ADDRESS LEGAL DESCRIPTION T12N R3W Section 33 Lot 52 STREET LOCATION NHN Sabine Road 6. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] One [] Four L~ SINGLE FAMILY I~] Two [] Five [] MULTIPLE FAMILY [] Three :~X Six [] Other 7. WATER SUPPLY :Xl~l~t~ INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled [] COMMUNITY since June 1975. For wells drilled prior to that date, give well [] PUBLIC UTI LITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM ~ iNDiViDUAL/ON.SiTE~ **If individnal/on-site, give installation date 19"Z$/74 . If system is over two (2) yeats old an adequacy test is required [] PUBLIC UTI LITY by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010(3/78) THIS SIDE FOR OFFICIAL USE ONLY DATE RECEIVED "'--'---~ INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR I NSP ECTO R INSPECTOR DIRECTIONS: 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [/~/~/SI N G L E FAMILY [~] ONE [] THREE [] FIVE [] OTHER ~ MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY I~/~"" INDIVIDUAL DEPTH OF WELL E~] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3, SEWAGE DISPOSAL SYSTEM PERMIT NUMBER I~DIVI DuAL/oN -SITE CATE INSTALLED []PUBLICUTILITY I ~ "~ ~- Connection Verified Size: ,~ ~ If Tank is homemade SOILS RATING give dimensions: ~ ~.~ TYPE OF TANK M A N U F~.~ ~-'G~ . TOTAL ABSORPTION AREA MATERIAK , ,. ~ A 4. DISTANCI~S'i~ELLvv TO: Septic/Holding Tank Ab~rption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS O  APPROVEDFOR__~ BEDROOMS  DisNDITIONAL APPROVAL (letter m~t accompany certificate} DATE / '~'~'~ ( t ) /// LEGAL DESCRIPTION 72-010 (Rev, 3/7S) I'4UNICIPALI~¥ OI-'~'A\~C)J:P/'J2d,.~i~ / ~~ ~ ( DO ~ : ' ' ~ :~' ~ ~ , ~ C AN~]~ORAGE -~ ~(equest ~or Approva~ ol ]~kd vsdua]. ,~ov. cr a~lct ~,~aLc_r ~'ac}, ~,, RECEIVED ]. Property Owner: EIVIN & ~RY BRUDIE Mailing Address: .._~6_K P~S~P~_~gh~a-g~.-A~ Pi(one: 33~-65~5. Name of Buyer-: ..... ~s_~a.~e~_as~._a_b,o_v_e_ ................................ Mai] Jng Address: .................................... } hen .. Lend in g Mailing Institnbion: ALASKA PACIFIC BANK Realtor/Agent: none Mailing Address: Legal Description: L52, Section 33, Township 12 North, Range 3 West - s~ga~cr-~idY~n Street Location: NHN Sabine Road Single Family Residence: Mulhi. ple Family Residence: ( X~ Number of Bedrooms: ( ) Number of Bedrooms: 7 . Water Supply: * Individual Well ( X~ Publ. ic/Columuni ty System ( ) If Co~mnunJty System, name of system Sewage Diaposal System: *';On--site System kX) Public System ( ) *NOTE: A well log is required on ALL wells drilled since 6/75. ** If on---site sewer syshem is over two(2) yeats old, an adequacy tush is required by hhis departmenk. A fee ef $25.00 must accompany each request before procesaLng can bo in:i Lliabod. 3/77 MUNICIPALITY OF ANCHO~AG~ January 8, 1979 R&Mgt~RO~Sg~I~06 i, ,3 ,~C~tON Mr. Elvin Brudie 726 K Street Anchorage, Alaska 9950] RECEIVED Re: Adequacy Test on Existing Sanitary Sewer System; Lot 52, Section 33, T12N, R3W, S.M., Alaska Dear Mr. Brudie: Per your request of December 26, 1978, we conducted a test of the sanitary sewer system on the above described property. During this tes{ the liquid level in the septic tank was monitored as water was added to the system. The measurements are sunmmrized in the following table: Liquid Level Below Top Total Gallons Time of Standpipe Added 11:05 10.8' 0 11:20 10.7' 50 11:45 10.7' 150 12:10 10.7' 250 12:12 10.8' 250 12:15 10.8' 250 12:30 10.8' 250 The meter used during the test was a Rockwell 5/8" standard water meter which had previously been calibrated by R&M Consultants, Inc. If the 6 bedroom residence on the property is to house 12 people, the average load on the system can be expected to be 900 gallons per day or .63 gallons per minute. During the test, the system accepted 250 gallons in 67 minutes. This indicates an average effluent acceptance rate of approximately 3.7 gallons per minute at the time of the test. Because the house on the lot is occupied, we assume that the leach field was at its normal degree of saturation. We can therefore conclude that the system is disposing of effluent at an adequate rate for a 6 bedroom resi- dence. January 8, 1979 Mr~ Elvin Brudie Page -2- We appreciate this opportunity to be of service to you. Please contact us if you have any questions concerning this test or if we can be of additional service. Very truly yours, R&M CONSULTANTS, INC~ Ernest R. Raha±m Staff Geolog±st ERR/GAS/12-A