Loading...
HomeMy WebLinkAboutT12N R3W SEC 33 LT 139 POL t (i (907/ 264 ,11 II Permit #: 840209 January 31, 1985 TO: Permit Applicant SU]IJEC?: T12N R3W SEction 33 Lot 139 A permit issued by this Department for an individual well and/er on-slte sewer system has expired as of December 31, 1984. Permits are issued on a calendar year basis by authority ef Municipal Ordinance. A new permit must be obtained frem this Department fer ally well and/or en-~site sewer system net installed by the expiration date. If you have drilled the well, a well 10g needs to be sent to this Department for documentation of the instdllation and to close tile permit. If a private engineer inspected the instal!ation of the on-site sewer system, the original as-built inspection report and the ye].low copy must be sent ~o this office for review and approval, and for documentation. If there are any further questions, please call this office at 264-4720. Sincerely, · - : . , oupeYvisor Envirenmental Engineering Pregram KEB/ljw enc: Copy of Permit SWP/057 E,I ....I ....NFl Permit Applicant: Location: Legal Description: Department ~ Health and Environmental ~rotection 825 Street, Anchorage, AK. 501 264-4720 * * * HANDWRITTEN PERMIT *'* * WELL AND/OR ON-SITE SEWER PERMIT /~/z~/V ~ ~;~Z b/J~-,~ Mailing Address: 7-f/~/~z~v ~/~ Phone Number: ~-/~f ~J~/ ~3Z~/ ~ ~. Lot Size: Type of Soil Absorption System Is: Trench: Drainfield: Maximum Number of Bedrooms: ~ The Required Size of DEPTH ~. LENGTH ~-~-./7~' / Seepage Bed: /,~ Holding Tank: Soil Rating(sq.ft/br) ~ the Soil Absorption System Is: GRAVEL DEPTFI ~--~ WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width f~r trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE = /~--~$~ GALLONS * * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion° Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 31~ 1 9 * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if t~id~c~ ~e m~~ Applibant ~ include more ~bedro0ms. Issued by: Date: ~'~/j-'~,~/,J~'/7 // SWP/024(1/81) ~: :.r r.. I I,~:l,i I '""~-' ,~,r I k..... ~ ~, F:llq[:' Ii~;1",!',,,' ]] F;i:OI",ff"II~i:I',ITI'::IL.. I" ..,~ ...... '"1..'" .... I F..E.k.]., Ill'Jul R.JI..I ILL. FII< '" ~'~' ' J:ll~, I~ ,'..].,'LI'.. '"-' ' .................... L:.I~ ,, L ,:. , ,,=."'"' I.'- I1,::.11 ........... ...... II~ ,,. ,,-. % ,.-,::. , ............. ,.,~ , ..... F'E:F.:M I T ~" '-' ':' '~ '" ::' '* c,r'...,, ..... ,...-c ,-',, c',~, L]: ,'--'n~ ~, i' .., I .......... '"'"" -,;.,, , ........... ,....,'...,., [.~,...,~, ..UL[..I, ].-,I,-,J,~: hl?I E,t ........ I.,. I',1('1 L,.. I . LOT ":~-?'"" :i;'S'OI;]E; .......... F'q'. '~--' ' ' ..... """ ' .... SECT't: ]i'I: .......... ~- ':"'-' ,-,I..ll ,I.;,I I., I' : ..... i',~ L. ,I ...~£.: I ,, .,.,. ,,...,,, ,J...I t,~.,,.-F. 31 OtZ[:'I;;'.OCIM:::; .= 4 - " ' ':' "'""~ .... ' .... . :' ." .,I..~IL. I. I.*11.. = :!.lq~# .:1..,::.._ ::L?= ':.bh.~ F'T., LF.'... ....... :.,, I.L.. 12,11;;LOI...t , f.;.E:. TIlE -f I I ..hi .... , '" ': '" I Iv I ,... LI I1:: LI:::. '¥'l]t yI]llJ Z I~d L I:.;..[ - I ,~ T J',d.a yIZILIJ';:I S;[:']:'T I C - :.:, f f::.1 I. CHOOSE; TI IE OI:::"T I Obi THI':IT ,-,[......, ~ I-~ 1; TE; ..... I .....Z []' r'l'' F'T. ! I',IOTE ! F']'. ! hlO'T'L] '. I'"II:1'.,' F~:E[6:!U I RE L I I:::T '-'~;TI::'I-F 1; 01',1 CI...I. I]l'::l[... L OI',t:]; ( TI,.IO lie II:112: ?,...~.. E::= I[:1::, E;Ei] ~]E:, % C]~ IP..,~ I'"T. ?I". * NI]FI"[: ' F']". ] I',IC:T'E; ! -. F?.E6¢J I RE:S :[ I',ISIJI._.I::IT ].' O1",1 FI". ! I',IOTIZ ! Mf:IY [;'.E];]UIF::I!; LIF'T '.:~',TFITZOI'-,I CU. ,'.']FIL. LOhlS (TI,JCl COMF:'I]I';:-FM,.SP4T r '- , .... I... ,'.., ,..,,- ~ h ,h,. , , IL:. :.., F T~. OF,': ,...,~ ': _,,' '"'... I_.1..., ......... Z-. L .I.H.:.:I I ......... II1, L]_. 141 : Department Permit Applicant: ~~ ;9' Location: Legal Description: ~3 ~ ,~ .~3 Type of Soil Absorption System Is: Trench: Drainfield: Maximum Number of Bedrooms: ~-'~. f Health and Environmenta3 Orotection 825 ~ Street, Anchorage, AK. 3501 264-4720 * * * HANDWRITTEN PERMIT * * * WELL AND/.~3~ ON-SITE SEWER PERMIT ~OL~2/~O~Lf~Mailing Address: ~-~ Phone Number: Lot Size Seepage Bed: ~ Holding Tank: Soil Rating(sq.ft/br) ~ DEPTH The Required Size of the Soil Absorption System Is: LENGTH ¢-~?-? . GRAVEL DEPTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED $EPTIC(H(~C-DTNG) TANK SIZE = /~3~ GALLONS * * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 fee~. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER ~1~ 1 9 ~ 3 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if ~i~e ~~eled_ to include more that~bedrooms. - -.K Signe~:~_/~:OL~.,~Q~../~g~f.~[//~._ __ ~ Issued by: '~-~-~) ~-~.--~. - Applicant Date: "In the event that a lift station is installed an electrical pem~,it and inspection must be SWP/024 (1/81) obtained. ,,',s-b,.;l':s cannot bo approved un- til the electrical h',sp.'.~c~ion ir_' i'ecoivnd in this office, The etectricai work must ba per- formed by a licensed electrician." MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L, Stroet, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST SOILS LOG PERCOLATION TEST LEGAL DESCRIPTION: T I~., N ~ ~'¢~'~ J Se C.~ SLOPE 10 11 12 13 14 15 19- 20- Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE [minutes/inch) TEST RUN BETWEEN FT: AND FT 72-008 (6/79)