HomeMy WebLinkAboutT12N R3W SEC 33 LT 72T12N R3W
Lot
018-261
-01
Permit Number: OSPl11110
Tax Code Number: 01826101000
Work Type: Septic
Permit Effective Dates: June 16, 2011
Design Engineer:
Subdivision:
On-Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 EImore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Upgrade
to June 15, 2012
PANNONE ENGINEERING SERVICE
T12N R3W SEC 33
Site Legal Address: T12N R3W SEC 33 LT 72 G:3035
Owner/Address: SELL TIMOTHY T &
MORRIS COLLEEN 14441 ROCKY ROAD ANCHORAGE AK 995163927
Site Mailing Address: 14441 ROCKY RD, Anchorage
Lot Size in Sq Ft: 108900
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Issued By: / f Date:
MUNICIPALITY
OF ANCHORAGE
Community Development Department
Development Services Division
On-Site Water & Wastewater Program
Mayor Dan Sullivan
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. Ol~;-
Property owner(s)l"~.,~OT/,~,'r'
Mailing address i~qq
Site address ! ~q~/ ~'
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section)
Lot Size i~ R¢O Sq. Ft.
Day phone
Number of Bedrooms'"--../~ '_'~
THIS APPLICATION
([] all that apply)
Absorption Field
Septic Tank
Holding Tank
Privy
Private Well
IS FOR:
THIS APPLICATION IS AN:
Initial []
Upgrade ~]
Renewal []
Water Storage []
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal Codes.
/
(S~g~ature of~pe~y owner or authorized agent)
Permit/Rush Fees:
Date of Payment:
Receipt Number: ~.-
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
G:\Building\On Site\Forms\Client Forms\Permit App_010411 .doc (Rev. 1/11 )
Cc) 1
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional En§ineer
E-mail: steve~panenRak.com
July 5, 2011
Municipality of Anchorage
Development Services Department
On-Site Water & Wastewater Program
4700 S. Bragaw Street
P. O. Box 196650
Anchorage, Alaska 99519
Subject:
T12N, R3W, Sec 33, Lot 72
Septic System Permit Upgrade Request
Ladies and Gentlemen:
I am writing to request a permit to construct an upgraded septic system be issued for this property. The
proposed systems will serve an existing three-bedroom house. Currently the lot is developed. The lot is
served by a private well. The existing drain field is in failure and shall be re-used as a reserve. The existing
1000 gallon tank was installed on 6/18/2011 with permit OSP 111110. A new drain field will be installed
north of the existing field and will be sized to handle a three-bedroom waste stream. The surrounding
developed lots are served by private water systems. The private wells are located over 100 feet from the
proposed soil absorption system.
1. Soils. Two test holes were excavated by Pannone Engineering Service in June of2011, one of which
was in the vicinity of the drain field. See the soil logs attached. Grotmd water was monitored for seven days.
No ground water was monitored to a depth of twelve feet (12') below ground level after the monitoring
period. Bedrock was not encountered in the test hole. It is my opinion, based on the results of the percolation
tests and overall soils appearance; an application rate of 1.2 gallons/day/square feet should be used, using a
conventional wastewater treatment system.
Soil Absorption System Design.
a. See Sheet 2 of the design package
3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and the
existing drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water
and drainage ditches.
4. Topography: The average topography in the area of the proposed septic system is approximately 5
percent based on the survey information in the area of the septic system. There are no steep slopes within the
vicinity of the proposed drain field.
Yelephone: (907} 272.-8228 FAX:
Page 2 of 2
5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification
that the review is complete and that there are no further comments is received from MoA On-Site
Department, the note will be removed and "Issued for Construction" drawings will be issued.
The proposed installation will not affect the future development of the surrounding or existing lots. There
are no wells or septic systems within 100 feet of the proposed septic location.
If you have any questions or concerns, please contact me at 272-8218.
Sincerely,
Steven R. Pannone, P.E.
Owner/Civil Engineer
Attachments:
i,/a !ir'~&i2 P~O~ Box !00212~ Anchora6e,~ AK 99510,-0217
E 144TH AVENUE
ff (2EA)22LFx3'EDxS'W, 6'TD . ' ~, z~ ~ ~DV
/ DRAIN FIELD (E)IN FAILUREx I ' '"
/ TO BE RE-USED AS RESERVE ~
-' ' AREA UNDEVELOPED
NO WELLS OR SEPTICS
FOR CONSTRUCTION p.o. BOX 100217 ANCHORAGE, AK 99510
TIMOTHY SELL & COLLEEN MORRIS rj,~.. 149 ..~ PERMIT NO.
PLAN ANCHORAGE, AK 99516 ,lli%o~0~S{~A~ Sheet
SPECIAL PROVISIONS TO SPECIFICATIONS
1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF
ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF
ON-SITE WASTEWATER DISPOSAL SYSTEMS.
2. ALL WORK SHALL BE IN ACCORDANCE WITH THE All'ACHED SPECIFICATIONS.
5. SCOPE OF WORK: INSTALL NEW SOIL ABSORPTION SYSTEM.
4. NO GROUNDWATER WAS OBSERVED AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS
OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 12.0 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER
IMMEDIATELY.
TH-1 ,///-~1LTE R FABRIC
,~;-~--, ~ GRAVEL BEDDING
GP/ t --'f- ~ 4"¢ DRAIN PIPE
GP/ 6.0
~ ~roundw,ter
~nitored
SECTION
~ ~ 80~ F4" DiD Peff Pipe O~
SEPTIC TANK =
PROFile ii
(2 EA) DEEP TRenCH SEE DESIGN
~E~IO~ PA~AMETE~ LEOE~D
PRIMARY SEPTIC SYSTEM
NO. BEDROOM: 5 (450 epd) W. WATER LINE/ ABBREVIATIONS
TANK SIZE: 1000~ WELL RADIUS CU COPPER
PERC RATE ~ 1-~ MPI DIP DUCTILE IRON PIPE
SOIL RATINO: 1.20PD/SF ~ SS NEW SEPTIC TH TEST ~OLE
AREA RQD: ~75 SF FC FOUNDATION CLEAN OUt
SYS. ~PE: WIDE TRENCH 5.0' E.D. T¢ TANK CLEAN OUT NO.
RF: 0.58 C¢ CLEAN OUT NO.
MIN LENGTH: 45.5 LF MC MONITOR TUBE NO.
USE: RJ. RIGID INSU~TION
(2EA) 22 LF X 5' WIDE, 5' E.D., DCO DOUBLE CLEAN OUT
6' TD DV DIVERTER VALVE
TOTAL AREA: 579.5 SF FS FLOW SPLICER
FOR CONSTRUCTION p.o. BOX 100217 ANCHORAGE, AK 99510
PHONE (907) 272-8218 FAX (907) 272-8211 ~.. ~..~;"~Jifa Scale
T~2~, ~3W, S33, ~OT 72
14441 ROCKY ROAD rIl~... ..~¢~ 0SPl11110
DETAILS ANOHORACE, AK 99516 'i~;~¢s,V;~¢~.__~ ----- Sheet
__ /
SOILS LOG - PERCOLATION TEST
TEST HOLE 1
OR'ORGANICS SLOPE ~ ~N '~ t
1__ i
3--
SAND / SANDY
4 -- GP/SW G~VEL ~TH
ROCKS 6"-18" ~
5~
6 TH ~' ' ,~, ', ' ,,, ~ ' '~:~:~::~ '
7~
9 -- W~-~''~
10 ~ GP/SM SIL~
SAND/G~VEL
11
12 ~
BOH
13 ~
WAS GROUND WATER SLOPE
14 ~ ENCOUNTERED? N
~5 -- IF YES, AT WHAT TH
~ 6 ~ DEPTH? -0-' X
~7 ~ DEPTH TO WATER AFTER
MONITORING? -DRY-
18 DATE: 6/25/11
DATE PERFORMED: 6/18/11 READING DATE ~ CLOCK
WATER
NET TIME LEVEL NET DROP
~ TIME
i READING
1 6/18/11 2:00 --- 2.70 ---
2 2:10 10 MIN 9.97 7.27
3 2:10 --- 2.70 .--
4 2:20 i 10 MIN 9.85 7.15
5 2:20 --- 2.70 I ---
6 2:30 10 MIN 9.81 I 7.11
WATER
READING DATE CLOCK NET TIME LEVEL NET DROP
TIME
READING
1 6/18/11 2:00 --- 2.70 --.
2 2:10 10 MIN 9.97 7.27
3 2:10 ___ 2.70 .__
4 2:20 10 MIN 9.85 7.15
5 2:20 ___ 2.70 ___
6 2:30 10 MIN 9.81 7.11
PEROLATION RATE 1.4 (min/inch) PERC HOLE DIAMETER 6 inches
TEST RUN BETWEEN 4 FTAND 5 FT
COMMENTS: Test hole excavated by PANNONE ENGINEERING. Prec hole was presoaked.
Test run for one hour. Last 3 readings reported
PERFORMED BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST.
~'~.-~"-~"--~-'~.'~· ,. D a t e
.~.. OF A
,OTES: PANNONE ENG SVC, LLC ·
FOR CONSTRUCTION p.o. BOX 100217 ANCHORAGE, AK 99510
.....L I 7/44/11
PHONE (907) 272-8218 FAX (907) 272-8211 ~,~..- ~:!.~ Scale
~'.' 49 ~--- j~ '.~'~ 1"=50'
P.I.D. NO
T12N, RSW, S33, LOT 72 _ -018-261-01
14441 ROCKY ROAD ~.~.. ..~.~x~.~ OSPl11110
SOILS LOG ANCHORAGE, AK 99516 i,~ ...... ~ Sheet
Permit Number: OSPl11110
Tax Code Number: 01826101000
Work Type: Septic
Permit Effective Dates: June 16, 2011
Design Engineer:
Subdivision:
On-Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 EImore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Upgrade
to June 15, 2012
PANNONE ENGINEERING SERVICE
T12N R3W SEC 33
Site Legal Address: T12N R3W SEC 33 LT 72 G:3035
Owner/Address: SELL TIMOTHY T &
MORRIS COLLEEN 14441 ROCKY ROAD ANCHORAGE AK 995163927
Site Mailing Address:
14441 ROCKY RD, Anchorage
Lot Size in Sq Ft: 108900
Total Bedrooms: 1
This permit is for the construction of:
N Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Date:
Date:
Pannone Engineering Services LLC
Steven R. Pannone, Principal
Registered Professional Engineer
E-mail: steve@panenRak.com
June 16, 2011
Municipality of Anchorage
Development Services Department
On-Site Water & Wastewater Program
4700 S. Bragaw Street
Anchorage, Alaska 99519
Subject:
T12N, R3W, S33, Lot 72
Emergency Septic Tank Replacement Permit Request
Ladies and Gentlemen:
I am writing to request that a permit to install a new 1000 gallon Septic tank be issued for this
lot. The proposed systems will serve an existing three-bedroom house. Currently the lot is
developed. The existing septic system was designed and installed for a three-bedroom house and
is operating adequately for three bedrooms. The existing steel 1000 gallon tank is collapsed. The
damaged tank is exposing the raw sewage to the environment. The existing tank will be filled
with clean gravel or concrete and abandoned per code. The surrounding lots are served by a class
private water systems, with a class 'C' well on the west side of Mosley Lot 73B, and there are
no wells within 100 feet of the proposed septic tank. This lot is served by a private well that is
over 100' from the proposed septic tank. PES will verify all required separation distances at time
of installation.
Upgrade Tank Design.
a. See Sheet 1 of 1 of the plan set
2. Surface Water: There is no surface water within 100 feet of the proposed system. The
proposed systems will maintain at least 100 feet from all surface water and drainage ditches.
3. Topography: Lot 72 slopes, from northwest to southeast at approximately 10% in the
area of the tank replacement. The proposed installation will be located in the west-central portion
of the lot next to the existing septic tank and absorption system.
Mai!icily P.O. Bo)< 2.002] 7, Anchorage, At( 995S0 02.i7
P/'~ys; cai; 6:i.5 East 82~''~ Ave, C.~ite B6, P.;~cl:~orage, AI< 99503
"ielephone: (907} 272~-82t8 FAX:: (907) 27282i. 1
· Page 2 of 2
The proposed installation will not affect the future development of the surrounding or existing
lots. There are no wells or septic systems within 100 feet of the proposed septic location. If you
have any questions or concerns, please contact me at 272-8218.
Sincerely,
.o:~ ~, ............. ~ ?,;4
.-%'..: .....
i'"'""' ........ : "'t
Steven R. P~one, P.E.
Owner/Civil Engineer
A~ac~ents:
E 144TH AVENUE
/ " l O00g SEPTIC TANK (P) / X
A~p DOUBL~ CLEAN OUT~ / '
/~ ~ ~ COL~PSED l O00g SEPTIC TANK (E)~
[ [ _~ ~ ABANDON PER CODE~
EXISTING
SEPTIC AR~
AREA UND~ELOPED
NO ~ELLS OR SEPTICS
EMERGENCY REPLACEMENT P.O. BOX 100217 ANCHORAGE, AK 99510
P,O~[ (~07) 272-8218 F~X (~07) 272-8211
T12N, R3W, S53, LOT 72 ~ ........... ~ P.I.D. NO
TIMOTHY SELL & COLLEEN MORRIS~ '~
xxxxxxxxx
PLAN ANCHORAGE, AK 99516 .?¢~A ..... Sheet
STATE OF ALASKA
DEPARTMENT OF NATURAL RESOURCES
DIVISION OF MINING & WATER MGMT
LOCATION OF WELL WATER WELL RECORD
BOROUGH SUBDIVISION LOT BLOCK SECTION Q. TRS SECTION TOWNSHIP RANGE MERIDIAN
LOCATION/SKETCH: WELL OWNER:
/ ~.~, t.~,.,~t
DEPTHS M~SURED FROM:~casing top ~ground surface WELL DEPTH: DATE OF COMPL~ION
Depth of hole: -':' ?~ ~ ft
BOREHOLE DATA: Depth Depth of casing:'
,~,~r~al Type and Co!ct Frcm To
.:"~'~ ,~ ' , DEPTH TO STATIC WATER L~EL:
.... ~ "?~ "~;' ft below ~ top of casing ~ ground surface
:::~' M~HOD OF DRILLING: ~' air rotary ~ cable tool
"~ /'"' " ' ~ ' 7 't::.-~ ~ other
........ , USE OF WELL: ~ domestic ~ irrigation ~ monitor
......... . ........ :. ,'.'::~, .~-~ Y"- "~: L"~ ~:~ :~ D public supply ~ other
'~'." '. : ...... ' ~',' ~ ~ :,-',..., ,:~ ""' ~:~ ~'~ Casing type: .~",, ~-:: ....... in. to ft
' .... ' . WELL INTAKE OPENING TYPE: ~ open end ~ screened
' ' ';" ~ perforated ~ open hole
";' ';: ' .... Depths of openings: to ft
:':'~ .:: :. .:.....,. ,~ ...... ,, -~ : ~, .;,? ~ /
'~ ..... .... ".. ..... ,...:: ' SCREEN TYPE: Diem:
, , :~, ,., , in.
..... ::": ....... ' .... : ' Slot/Mesh Size: Length: ft
GRAVEL PACK TYPE:
Volume used: Depth to top:
~'' '"" I'::?:' :T'
Depth: from ft to ft
, D~ELOPMENT M~HOD:
SEP 2 z~ ][ 98 Duration:
Mun~c~pahty of Ar :borage PU~PING L~EL AND YIELD:
Dept. Health & Hum, n Ser4io~s ' ' "~ ft after "~ '"t"
..... hrs pumping gpm
PUMP INTAKE DEPTH: .... ft Horsepower:
WELL DISINFECTED UPON COMPL~ION? ~.YES ~ N~
CONTRACTOR INFORMATION:
Registered Business Name ..,,
SignatUr~:-of , . ,,.,
Authorized Respresentative
Date
REMARKS:
PLEASE MAIL WHITE COPY OF LOG TO:
DNR/DIVISlON OF MINING & WATER MGMT
3601 C St, Suite 800
ANCHORAGE AK 99503-5935
Phone (907]269-8639, Fax (907}562-1384
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
PAGE
1 OF
ON- SITE WELL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW960364
DESIGN ENGINEER:
OWNER NAME:SELL TIMOTHY T
OWNER ADDRESS:14441 SNOWSHOE LN
ANCHORAGE, AK. 99516
DATE ISSUED:il/12/96
EXPIRATION DATE:il/12/97
PARCEL ID:01826101
LEGAL DESCRIPTION:
T12N R3W SEC 33 LT
72
LOT SIZE: 108900 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT:
3
THIS PERMIT IS FOR THE CONSTRUCTION OF:
WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAACS0) .
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
DATE:
DATE:
· LYS#
~ ..... ,,~ so, ~__ !? -~'~.~ /- ~ ~'~ ~.
j ~-~ /2o~ ' .' ". ,~
,, U~ DI~S PR~NL O~ ~NG. R~R~U~ON MAY CAU~ ~R~S
~ ~ ~ SURLY ~E
~ ~.o~ ~m S~BOLS
~ ~T ~ . . . ~[T... ~ ~ . . . ~y O F~ND R~ O c ~ ~D ~ ~ ~NCR~
~ ~ILT , . , NO ~ ~ ~ ~R~ A~LT... NO ~ ~ ~ ~UED ~. X ~ X M~AL ~ ~ ~D DE~
PLOT PLANS ~ LOT SUR~ ~0~:
IT IS ~E RESPONSIBID~ OF ~E BUlmER OR O~ER, PRIOR TO ONLY ~OSE IMPRO~EN~ ABO~ GROUND AND ~SIB~ ~ BE
CONS~UC~ON. TO ~RI~ PROPOSED BUI~ING GR~E RE~ ~O~. F~C~. ~ SEP~C C~ANOU~ ~DEWA~S, DRI~WA~.
TO ~NISH~ GRADE ~D U~D~ CONNEC~ONS AND TO DE.MINE ~.. ~E SHO~ IN ~EIR APPRO~MA~ LOCA~ON. ONLY. SNOW
~E ~IS~NCE OF ANY EAS/M~, CO~N~ OR RES~IC~ONS , MAY PRaT SOME: IM~RO~MEN~ FROM B~NG ~ AND LOCA~D.
~JCH DO NOT APPEAR ON ~E RECORDED SUBDI~SION P~T. A~ DISTANCES ARE RECORD UN~ ~S O~ER~SE NO~D.
~R~Y C~RCA~ON
~~ ~. _ Prepored by
~o~.~.~%~7%. Robert E Johns Jr · Assoc
~ ~ ~, ......... '~ee Professional Lend Surveyors
~e: R~ ~t ~F, R~. Pier ~e No.
F~NDA~ A~ILT .-~, ~. ~. ~
~~'~ ~%~SO(I,i~n~%~TM LOT 72 ~ SEC 33 ,T12N, R3W, SM
RECEIVED
NOV 1 2 199~;
_ Municipality of Anchorage
-:. uept, Health &.Human Services
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGSNEER~NG DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
· ~ ,~____.~:.. J..~HON E ' '-J ~,~1 EW
MAILING ~RESS
LEGAL DESCRIPTION
LOCATION NO. ~B EDROOMS
J ~ell /~' _ lAbsorPtion.area PE~IT N~(,
Man u factu rer~DISTANCE TO: ~ [~¢ ~ ~'~ ~ ~/~ MDW~g/i
~ ~ __: ~/~ - ~ ~Z~ N°' °~mpartments
, Liq. capacity i~,gallons Inside length Width Liquid depth
/~ ~ IF HOMEMADE:
~ ~ Well Dwelling PERMIT NO.
~ ~ ~ DISTANCE TO:
O ~ ~ Manufacturer Material Liquid capacity in gallons
O Well ~ [ Foundation/ Neare~ line
~ N°'°flines.~-- , ' , . , , inches
Lengt~flea~h¢~e~ Total leng~e~ ~wid~ Distance bfftweeq lines
~ ~ Top of tile to finish grade Material beneath tile
~en~th ~idth Deoth ~E~MIT ~0.
~ ~ T~e of cdb Crib diameter Crib de~th Total effective absor~don area
m Well Building foundation Nearest lot iine
~ DISTANCE TO:
~ Class Depth Driller Distance to lot line PERMIT NO.
~ DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s)
OTHER I
PIPE MATERIALS
SOl L TEST RAyNe ~/
-.
INSTALLER "
REMARKS
APP~ DATE LEGAL
72-0~ ~ev, 3/78)
DEPTHs. ( LENQTH= 4B QR~;)VE~_ DEP l"H-~-~
THE LEIi~Jl~ OI~J(~I~ I$ THE LENOI~ (IH FEET)
~ DEPTH C)~ R T~J~H ,::ff~ PIT I'~ ~ DI~TF)fiF'~ I~ET)4IEffN TH~ '~JRF*~"~F_ OF ~
..................... ~... * ~:. ~- 'T' !F-i!
'r"-lF' ~ c~".h':'t"~'",: , .... ,__ -, ..,: _; r'~" h' F'.;--.;'::; .... lq ;{~: T~.-iC';, ..... i_E~'.,tf}TN *:: ~'~.,I
, ,.. ..... ! ....... ("i~? F'Z"F T,: THE F' T':;TCI~..tf"';:' i:::~C"T'ht~:'~:'~.J T~4C ;::
~m,'-¢**. r'-, ¢:ffJO THE E:(}T'FOhl OF' "F~-~E E;:':;E:fi'v~FlTZqh
"r'''''. r':~:: GF:FIVEL. ...'"c'F"F~ ........... 'r,:. "r~:':: ,_ *'~'r*4*hiUhl, ~.,~,;:. DF-F"FH OF' F~PF?,.,'c'~ ~ g'T.,.iF'F:?.;i '}'L.~c ,_._3 cFc:'~:S ......... C:: 'r c,c'
Fff';IE:' THE EffE;T'Y'Er'I OF 'T'NE: E;:.:;E:F?¢FFF]:ih. ,:]iN FEE"F::,.
FEET
...... ~ . ...............
Alaska Testlab
4040 "B" Street
Anchorage, Alaska 99503
Phone (907) 278-1551 ( Telecopier (907) 272-5742 )
September 14, 1981
W.O. 9A20086
L.T. Kegler
Star Route A
Box 253
Anchorage, AK
99507
Subject: Lot 72f Section 33, Tol2N., Ro3W., S.M.
Dear Mr. Kegler:
We have completed our soils investigation concerning the
suitabilty of an on-site waste water disposal system on
Lot 72, Section 33, T. 12 N., R. 3 W., S.M.
Two backhoe test pits were excavated by the property owner,
Mr. Kegler. The. test pits were logged by Mr. Jim Mack,
laboratory supervisor for Alaska Testlab.
Test Pit %1 was excavated to the west of the proposed struc-
ture as indicated on the enclosed plot plan. The surface
elevation of the ground at this locatioa was approximately
the same as that at the proposed building site. Test Pit ~2
was excavated 32' directly south of Test Pit #i. Surface
elevation of the ground at this location was approximately
10' lower than that of Test Pit %1.
The soils conditions in Test Pit %1 and %2 are described in
the enclosed field logs.
Absorption trenches are suitable for this lot. The recom-
mended absorption rate per bedroom should be derived from
the criteria described for (GW) sandy gravels as described
in Table 1 of the current Anchorage Municipal Code for Waste
Water Disposal Regulations. A GW soil classification
requires 85 square feet of absorption area per bedroom in
the absorption trench.
Mr. L.T. Kegler
September 14~ 1981
Page 2
We would advise locating the proposed absorption trench in
the vicinity of Test Pit 92 due to the topographical fea-
tures and also due to the floor elevation of the basement of
the proposed structure.
If you have any questions please contact our office.
Very truly yours,
JDM:rb
Enclosures
A~~SKA TESTLAB
J~mes D. Mack, C.E.T.
APPROVED
~.~elvin R. Nichols, P.E.
Laboratory Manager
IU'O
J
0
L)
Test Hole I
Table A
Date: 9-!-81
Logged by: JDM
W.O. # A20086
Depth in Feet
From To
0.0' - 0.5'
0.5' - 10.0'
10.0' - 16.0'
Soil Description
Topsoil.
Sandy Gravels with cobbles (GP-GW), slight
water seepage at minus 10' .
Medium Silty Sandy Gravel (glacial till),
(GM).
Bottom of Test Hole:
Frost Depth:
Free Water Level:
Remarks:
I.
2.
3.
4.
5.
6.
16.0'
None Observed
10.0'
Type of Sample, G = Grab, SPT = Standard Penetration,
U = Undisturbed.
Dry Strength, N = None, L = Low, M = Medium, H = High.
Group refers to similar material, this study only.
General Information, see Sheet 1.
Frost and Textural Classification, see Sheet 2.
Unified Classification, see Sheet 3.
Test Hole 2
.'Fable B
Date: 9-1-81
Logged by: jDM
W.O~ # A20086
Depth in Feet
F rom To
0o0' - 0.5'
0.5' - 8.0'
8.0' - 10.0'
Soil Description
Topsoil.
Sandy Gravels with cobbles (GP-GW). The
depth of this layer appears to be'
increasing in the downslope direction.
Silty Sandy Gravels (glacial till).
water seepage at -10'.
Slight
Bottom of Test Hole:
16.0'
Frost Depth:
None Observed
Free Water Level:
Remarks:
1. Type of Sample, G = Grab, SPT = Standard Penetration,
U = Undisturbed.
2. Dry Strength, N = None, L = Low, M = Medium, H = High.
3. Group refers to similar material, this study only.
4. General Information, see Sheet 1.
5. Frost and Textural Classification, see Sheet 2.
6. Unified Classification, see Sheet 3.