HomeMy WebLinkAboutT12N R3W SEC 33 LT 192 · ~ ' MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALT~ & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LOCATION Well /. O Absorpti a / Dwelling ( ~' ~Li~c~y in gal,o~ IF HOME,DE: inside length ~,,~Width Liquid depth DiSTANCE TO: [Well /f / ~ JDwelllng PERMITNO. Manufacturer / ~ ~/~ Liquid capacity in gallons [] NEW NO. OFBEDROOM&..~ No. of corffpar[ments //. DISTANCE TO: IWe. /Z /-/ ¢ Length o~aj~_~ n e Material Fou~o~.~ /' Nearest I~l~ne /_ PE~vl~[~?.~.~,.~_TNE]. ~ Trench ' th t~ T°tal leng~Q~jnes I ~-~t~ inches I DistancJ bet~lq ~¢~ M ri I ben h t'le Total effectiv absorption ar Depth , PERM T NO, No. of lines Top of~.~ t~'f~.~h grade Length Type of crib DISTANCE TO: DISTANCE TO: Width CWrll~ d,ameter~//~ Crib depth Building foundation Driller Building foundation Sewer line OTHER PIPE MATERIALS Total effective absorption area Nearest lot line Septic tank Distance to lot line ~sRo r~it~o~ea (si DATE LEGAL ~IUNICIF~ALITY OF= ANC]~]F~AGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L STREET, ANCHORAGE, AK 99501 264-4720 PERMIT NO: DATE ISSUED: ON--'S ]~ TE 07/16/$4 ~ .~ SE~EF~ APPLICANT: C/O S & S ENG~G. MIKE COGOER ADDRESS: SRB 196X EAGLE RIVER~ AK 99577 CONTACT PHSNE: 694-2979 LEGAL DESCRIP: SUBDIVISION: NA LOT: 192 BLOCK: SECTION: 53 TOWNSHIP: 12N RANGE: 5W LOT SIZE: 2.5A (SQ.FT. OR ACRES) LOT LOCATION: 4100 RABBIT CREEK ROAD NA IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES~ ]'HEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUS~ BE OBTAINED; (2) AS-BUILTS WILL NOT BE AFFROVED~ITHOUT AN ELECTRICAL INSPECTION REPORT, AND (.~.) THE APPLICANT ~/O~S & S ENG'G. MIKE COGGER I certify that: 1. I am familiar wi'Lh the requirements for on-site sewers and well~ as. set forth by the Municipality of Anchorage (MOA) and the State of AlaskaJ 2. I wilI install the syste~ in accordance wi{h all MOA codee and regulations~ and in compliance with the design criteria of this p~?'mit. 5. I will adhere to all MOA and State of Alaska requirements fop the set bask distances fr()m any existing well, wastewater disposal system or public sewerage system on this or any adjacent or nea~'by lot. PERFORMED FOR: LEGAL DESCRIPTION: 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVl RONMENTAL PROTECTION 826 L, Street, Anchorage, Alaska 99501 264-4720 SOILS LOG -- PERCOLATION TEST SLOPE DATE PERFORMED; SITE PLAN [] PERCOLATION TEST 10- 11 13-- 14- 15- 16- 17- 18- 20- COMMENTS WAS GROUND WATER ~ i~ ENCOUNTERED? pO E IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop ill_" PERCOLATION RATE TEST RUN BETWEEN 72-008 (6/79) / ,,~ .... (minutes/inch) APPLI('-'~IT FILLS OUT UPPER HAI~'~,ONLY Buyer Address ~//~R ~,ZiP Code Legal Description % J ~ M ~3 ¢ SEC -~3 LT J ~ 2 ~ Public Utility ~ s~, .i,.o~ /¢¢~5 72-023 {31~) TELEPHONE"(907) 562 5633 B Street Drin i lYsis Report for Total Coliform Bacteria TO BE COMPLETED BY WATER SUPPLIER WATER SYSTEM: // Water System Name I.D. NO. Mailing ~.~dress City SAMPLE DATE: SAMPLE TYPE: ~loutine .El Check Sample (for with lab ref. no. [] Special Purpose Mo. Day routine sample ) [] Treated Water [] Untreated Water SAMPLE NO. LOCATION 4 I I Time Collected Colleoted By 06.1220 (b) Rev. 1978 TO BE COMPLETED BY LABORATORY Ana ~/SlS shows this Water SAMPLE to be: Sa~isfactory - [] Unsatisfactory [] Samole too long in transit; sam 31e should · ~,.,--.mot.be over 48.,-h0urs o~d ~at- examination to ~ndlcate reliable results. Please sene new samDle, Date Received I - c~ ~) :'~ ~ Time Received /,(~04) Analytical Method: [] Fermentation Tube '~ Membrane Filter Lab Ref. No. Result* .~t~yst I I r-Tq BACTERIOLOGICAL WATER ANALYSIS RECORD READ INSTRUCTIONS BEFORE COLLECTING SAMPLE Date ColleCt e¢l Source a.m. Lib. No. ROBERTA, SHAFER CiViL ENGINEER 694-2979 January 22, 1984 ADEQUACY TEST WATER AND SEWER INSPECTION WELL INSPECTIONS AND FLOWTEST SITE PLANS ROAD DESIGN SOILTEST O N S~TE WASTE WATER DISPOSAL SYSTEM DESIGN EXCAVATION WORK Mr. Mike Cogger 4100 Rabbit Creek Road Anchorage, AK 99516 Re: Lot 192, Section 33, Township 12N, Range 3W Dear Mro Cogger: A field inspection was performed on January 17, 1984 of the waste water disposal system located on the referenced property. It was determined that the septic tank required pumping. Pumping of the tank was performed on January 19, 1984 and the tank was verified to have a capacity of approximately 750 gallons. Located apprsximately 30 feet from the septic tank was what appeared to be a pile of logs beneath the surface that made up an absorption area by the tank. Visible indications were that this absorption area had failed. The results of this inspection have concluded that the absorption area will require upgradi~ to accommodate your two bedroom residence. However, the septic tank appears to be adequate. The horizontal distances from the septic tank to the existing well are more~than adequate to meet the minimum requirements established by code. If we may?be of further service, please do not hesitate to contact me. / / Sincerg~,j~ //~/ RAs:blg Municipality of Anchorage Department of Health and Environmental Protection SR8 196X EAGLE RIVER, ALASKA 99577