ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP241179 PID Number: 018-292-64
Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ® Upgrade
Name
MATTHEW &ANNA PERMAN
ABSORPTION FIELD - EXISTING
® Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound
Site Address
15021 OLD SEWARD HWY, ANCHORAGE
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
4
GPD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Ft.
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
Fill added above original grade
Ft.
Gravel length
Ft.
148C
Township Range Section
T12N R3W 33
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To'
Septic Absorption
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank Field
Lift Station
Tank
Line
Ft2
Ft.
100'+
25'+
TANK ® Septic S.T.E.P. ❑ Holding
❑OtherWell
Manufacturer
GREER
Capacity
1500 Gal.
Surface Water
100'+ --
Material
HDPE
Number of compartments
2
Lot Line
10'+ __
NA
Foundation
101+ --
LIFT STATION
Manufacturer
Capacity
Gal_
Remarks Deep -burial septic tank
Alarm location
Electrical installed by
PIPE MATERIAL House to tank 3034 Tank to
3034
Installer PCN
drainfield
Drainfield CO/MT 3034
Inspector FWCS
BENCH MARK (Assumed elevation) 100 ft
Inspdection 15` 7/31/2024 8/1/24
Location and description
2nd
3rd 4t
MANHOLE TOP
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
OF '9���1
Conditional Approval: Date
Q., • •
i 7H
. 49
...................
Curtis Huffman
Septic Syste
Approved -
�� CE 128991 •��
Date
1
/Note:
ck
10/ '�0
,
� F'0 • • • • NP����
ROFESSIO
OFEW
this approval does not include well permit requirements.
.`-�-
\ �
(Rev 05/02/18)
PID:018-292-64 PERMIT:OSP241179
FIRST WATER CONSULTING
T12N R3W SEC 33 LOT 148C
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
hftp://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP241179
Work Type: SepticTank Upgrade
Tax Code Number: 01829264000
Site Legal Address: T12N R3W SEC 33 LT 148C G:3134
Site Mailing Address: 15021 OLD SEWARD HWY, Anchorage
Owner: PERMAN MATTHEW & ANNA R
Design Engineer: FIRST WATER CONSULTING
This permit is for the construction of:
Effective Date:
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
»enr
I.
Ucp� rtni<rtir
7/19/2024
7/19/2025
55612
❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: 1 '�> 15 "1 z-o i C--
Issued By: P L
Date:
Date: cy Z
4
ON -SITE SEPTICIWELL PERMIT APPLICATION
Parcel I.D. 018-292-64
Property owner(s) Matthew & Anna Perman
Mailing address 350 E Peltier Acampo, ' CA 95220
Site address 15021 Old Seward Hwy Anchorage, AK 99516
Day phone
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section) T12N R3W SEC 33 LOT 148C
Lot Size 55,612 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(Z all that apply)
Absorption Field
❑
Initial ❑
Single Family (SF) ER
(w/wo ADU)
Septic Tank
Gi
Upgrade ER
Duplex (D) ❑
Holding Tank
EJ Renewal ❑
Multiple Dwellings El
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable- Municipell _Codes.
(Signature of property -owner or authorized agent)
Permit/Rush Fees:Waiver Fees:
Date of Payment:
Z Date of Payment:
Receipt Number: !j / 72 s Receipt Number:
Permit No. LQ 19 -,,q 1179 Waiver No.
GAIDevelopment Services\Building Safety\On Site Water and WastewaterTormsUient Forms\Permit Application.doc
13030 Sues Way, Anchorage, AK 99516
907-350-9566 / firstwaterAK@gmail.com
!
!!
July 1, 2024
Municipalities of Anchorage
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
RE: SEPTIC TANK UPGRADE PERMIT
LEGAL: T12N R3W SEC 33 LOT 148C
The owner has requested that we obtain a septic permit to upgrade the existing aged steel septic
tank on the above referenced lot. We propose to install a 1500-gallon deep burial HDPE septic
tank per the attached design to serve the existing residence. No groundwater was noted in the
MOA on-site file, but if groundwater is encountered during installation an epoxy coated steel
septic tank may be required and/or the tank may need to be anchored for buoyancy. The lot and
area are served by private water and any encroaching wells, easements, … must be staked prior
to construction. The design will not impact any of the neighboring properties. Please contact us
if you have any questions.
Sincerely,
Curtis Huffman, P.E.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241179, Curtis Townsend, 07/19/24
FIRST WATER CONSULTING
NO WELLS WITHIN
100' OF PROPOSED
SEPTIC TANK
T12N R3W SEC 33 LOT 148C
DESIGN DETAILS:
VACANT
VACANT
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241179, Curtis Townsend, 07/19/24
Municipality of Anchorage Page
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · 'Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: 5OJ~qOH%~- PIDNumber: O1'~,~]
~: ~ ~ H ~T~o~ Wastewater System: D New ~' Upgrade
Address:
~o~ ~eo ~V' A~.o~ A~. ABSORPTION FIELD
Phone:
~-~ . . ~ No of Bedrooms: ~ ~DeepTrench ~ Shallow Trench ~Bed ~Mound ~Other
LEGAL DESCRIPTION so, Rating: Total Depth from original grade:
~ . ~ GPO/Sq. Ft.
Ft. Ft
~ Fill added above original grade: Gravel length:
Township: [~ Range: ~¢i Section: ~ O-~ [ ' Ft. q~ Fb
Driller: ~ Date Drilled: Stat[cWster Level: Installer: Date installed:
SEPARATION DISTANCES ~Septic U Holding U S.T.E.P.
To Septic Absorption Lift Holding ~ublic/Private Manufacturer: Capacity in gallons:
From Tank Field Ste(ion Tank Sewer Lines
Well- IO~' I~%~ ~ ~t- Material: ~ ~ N umber of Compartments:
Surface
Water [OO'-~ ~oo'. ~ ~ ~ LIFT STATION
LineL°t ~ [[ ~ ~ ~ ~ Size in gallons: Manufacturer:
Foundation ~¢
Drain
~.,, J
Remarks: ~PT{~A~ ~%~ ~ BENCH MARK
Location and DesCription:
Assumed
Emewt)on:
Eagle RIver, Alaska~O~7~ 2nd i~-~ qfl g ;
Department of Health and Human Services approval ~ <;;.,, ......
Reviewed and approved by: _ ~ Date: 7-/~ ' 7~ '-kx:-4
72 013 (Rev. 9/911 MOA 25
Permit No. SW940432
Page 2 of
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 ° Telephone: 343°4744
On-Site Wastewater Disposal System and/or Well Inspection Report
LO'F 1480, T12N R3W SEC 33 01829264
Legal Description: PID No.:
MT CO
COt CO2
G[~ADE
NBW
1250 GAL
S.T.
SHED
:)...GAL
SEPTIC TANK
FOO
ST1
ST2
CO3
C04
MT1
LOT 1 4.BC
EXISTING
4. 13DRM
HOUSE
,~,B3. i' NO WATER FOUND
NEW TRENCH
.)
[~-~/ EXISTING TRENCH
I
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE ,~q It ~(q~ ~ ~ ;~oem
DEPARYI~ENT OF HEALTH AND HUMAN~SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW940432
DESIGN ENGINEER:S & S ENGINEERING
OWNER NAME:HITCHCOCK IRENE LOU
OWNER ADDRESS:15021 OLD SEWARD HIGHWAY
ANCHORAGE, ALASKA 99516
DATE ISSUED:il/15/94
EXPIRATION DATE:il/15/95
PARCEL ID:01829264
LEGAL DESCRIPTION: T12N R3W SEC 33 LT 148C
LOT SIZE: 35356 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MU-NICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASICA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 (24 HOURS)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
AT THE TIME OF CONSTRUCTION, ENGINEER SHALL PERFORM AN
ADDITIONAL SOILS TEST TO A MINIMUM DEPTH OF 20 FEET TO
VERIFY NO BEDROCK.
RECEIVED BY: ~'~-~ ~-,c~
DATE:
ROBERT C. COWAN, RE.
ROBERTA. SHAFER, RE.
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
INSPECTION
ENGINEERING STUDIES
AND RERORTS
WELL INSPECTION
&FLOW TEST
SOILTEST
STRUCTURAL&
MECHANICAL
INSPECTIONS
ONSIIE
W/~STEWAT ER
DISPOSAL SYSTEM
DESIGN
October 27, 1994
CIVIL ENGINEERS
(907) 694-2979
FAX (907) 694-1211
MUNICIPALITY OF ANCHORAG~
Department of H~alth and Human Services
P.O. Box 196650
Anchorage, AK 99519
Req~t ~'o~z iss~ze a permit to replace the 6ept. ie S~6~ 6~'cu,~tg t/~.
four bedroom hoc~,e on .¢Jze referenced prop~.
A t~st hole was excavated and a percolation t~st performed. TL~
approximate location of the test hole is located on the attached site
plan. The monitoring tube within the t~st hole has been checked and
found to be ~Ly.
The exiSting syStem was reported to be in a state of failure. It is
an undocumented system th~£efore it is unknown if it meet~ M.O.A.
requirements. The syst~ is to be abandoned completely.
Attached is the proposed upgrade design.
We do not anticipate any adverse effects on neighboring properties by
th6 installa~on of the proposed septic sys£em.
The proposed 1250 ~allon septic tank is to be placed outside the we~
protective radius. Attached is a site plan which depicts the location
of the proposed tank.
If you require any add~onal inform~ion please do not hesitate to
contact us.
Sincerely,
ROBERT C. COWAN,
RCC/gk
ENCLOSURES
17034 NORTH EAGLE RIVER LOOP · SUITE 204 o EAGLE RIVER, ALASKA 99577
©
~o,~
30¥~JOdn ]
W
N,DOW
W3M3S
8~AO0
Z
)10021
~3M3S
3AI103~3
i1¥130/N01.i33S SSO~IO
zt
'S'I'N
ROBERT C. COWAN, RE.
ROBERTA. SHAFER, RE.
SEWER & WATER
INSPECTION
ENGINEERINGSTUDIES
AND REPORTS
SITE PLANS
ROAD DESIGN
SOIL~ESf
PERCOLATION
TEST
STRUCTURAL &
MECHANICAL
INSPECTIONS
ON-SITE WASTEWATER ~ZSPOSAL SYSTEM
CONSTRUCTION PRACTICES
MATERIAL SPECIFICATIONS
CIVIL ENGINEERS
(907) 694-2979
FAX (907) 694-1211
REFERENCE: Lot 148C, Sec 53, TI2N, R3W, S.M.
GENERAL:
The scope of this project includes the installation of a
leachfield trench and a 1250 gallon deep bu~al septic tank
ou~ide the 100' protective well radius to serve the four
bedroom r~sidence located on the referenced property. The
existing trench is to be abandoned in place. The existing 1250
gallon sept~c tank is to be excavated, pumped, crushed, and
abandoned in place. The existing septic system is undocumented
therefore it is unknown whether or not it meet~ M.0.A.
requirements. System is to be abandoned completely.
Construction shall be in accordance with the approved site plan
and design drawings, Municipal permit with any spe~al
provisions or con~ions, and all applicable State and
Municipal Wastewater Disposal Regulations.
3. The contractor shall be responsible for obtaining any necessary
underground ut~ty locates.
U~ess specifica~y agreed otherwise, the property owner sh~
be respo~ible for fin~ grading areas subsequently depressed
~rom soil settling.
Contractors i~ta~ng wastewater disposal systems must be
certified by the Muni~pal Heath Depar~ent for syst~
i~ta~ations. Owners installing their own syst~,s must also
receive prior approval from the Municipal Health Department.
SEPTI~ T~K INSTALLATION:
I. A septic tank is to be constructed by a certified septic tank
manufacturer. Co~truction shat~ include two 4" cleanout~ for
pumping access.
2. The septic tank shall be sufficiently bedded to preve~
sctt~g or shifting of the tank.
3. All Standpipes on the septic tank shall extend a minimum of 12
inches above final grade.
ON SllE
WASTEWATER
DISPOSAL SYSTEM
DESIGN
17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577
Page Two
Lot 148C, Sec 33, TI2N, R3W, S.M.
October 27, 1994
o
Sept~c tanks installed with less than 4' of cover shall be i~ulated.
A foundation cleanout shall be instatled one to four feet from the
b~ilding foundation. In the line between the tank and the leachfield
there shall be two adjacent clcanouts (u,less an effluent pumping system
exists within the septic tank}. These cleano~ shall be located on
und~turbed soil not more than 10' from the tank. The first cleanout,
in line, shatl be to clean toward the leachfield. The second cl~anout
shoal be to clean toward the septic tank.
Final grading over the septic tank shall be such that a positive slope
exists away from the septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
Excavate the proposed trench to the dimensrons shown on the design. The
bottom of the excavation shall be within 2 inches of level. If the
sideways of the excavation become smeared, they must be raked or
scratched {roughed-up) before gravel {sewer rock} placement.
Once the gravel is installed, the distribution pipe is to be installed
level with the perforations faced downw~d. Gravel is then to be placed
over the dist~bution pipe to provide a minimum of 2 inches of cover
over the pipe.
A sl~t barrier must be installed between the final gravel layer and the
native sod~ backfill. Ensure the silt bar~er covers the entire gravel
surface before placing backfill.
Mo~tor tubes shall be of four (4) inch diameter and installed
approximately in the locations shown on the design. The portion of the
mo~toring tube extending through the gravel shall be perforated from
the bottom of the trench to the invert of the distribution pipe. This
is equivalent to the effec~ve depth of .the gravel as noted on the
design.
Backfill over the final gravel layer must not be less than twenty-four
{24) inches. Insulation must be installed when the backfill depth is
less than thirty-six (36) inches. The fi~sh grade over the t~ench must
b6 mounded to prevent the fo~ation of a depression after set~ng.
UINIMUUUATERIAL SPECIFICATIONS:
I. Any septic tank proposed for installation must be constructed by a
Muni~pally approved septic tank manufacturer.
Page Three
Lot 148C, Sec 33, TI2N, R3W, S.M.
October 27, 1994
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Type of Pipe Perforated
Solid
Cast Iron Yes Y~s
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Y~s
Use of a type of pipe other than listed above must be approved by the
inspecting engineer.
Insulation shall be at least 2" thick ex~uded d~ect buria~ polystyrene
(Dow Chemical Company Styrofoam HI or equal).
Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
A permeable nontoxic silt barJ~er (Typar 3401, Mirafi 140/N, or equal)
must be installed between the final leachfield ~ravel layer and the
native soil backfd~.
All leachfield gravel (sewer rock) sha~ be 0.5"-2.5" screened gravel
with less than 3% pa~sing the #200 sieve.
When sand is being used as a filter material, it~ gradation
specifications must conform to current M.O.A. or D.E.C. requirements.
INSPECTIONS:
Typically there will be a minimum of three {$) inepections required during the
installation of the wastewater disposal system. Th~se inspections will occur as
follows:
The first inspection muSt be conducted after the excavation of ditches,
pits, trenches, or bed~ and before the installation of any gravel. A
septic tank may be set in place, b~ m~:y not be backfilled before this
inspection.
The second inspection must be conducted after the placement of the silt
barrier, gravel, distribution lines, standpipes, ~eanou~, and
insulation, but before the placement of any other backfill.
Page Fool
Lot /48C, Sec 33, T12N, R3W, S.M.
October 27, 1994
3. The final inspection is to occur upon final grading of the property.
Often there will be more than th~se 3 inspections required, especially with the
installation of multiple trenches, sand fi~ers, pressurized distribution
systems, etc. Thus, the inspecting engineer is to be contacted at least 24
hours prior to the start of construction. If necessary, a pre-construction
meeting wit2 take place onlsite. The inspecting engineer will not coordinate,
d~ect or control in any my the contractor's activities.
The owner sha22 contract with the contractor to perform the work outlined in
these specifications and plans and in accordance with the attached M.O.A.
permit. There will be no contractu~ arrangement existing between the
cont~Lactor and S & S Engineering. S & S Engineering shall be the owner's
representative and wi21 inspect the work as stated above to document the
cont~Lactor's activities. Final acceptance of the contractor's work rests with
the owner and the M.O.A.
S & S Enginee~ing shall have no tiability to the owner or to others for act~ or
omissions of the contractor or any other persons performing work on th~s project
or the lo, lure of the contractor to carry out the work in accordance with these
construction docu~ent~. S & S Engineering 's inspecting engineer will not be
responsible for the co nstruct~o n m~ans, methods, techniques, sequence,
procedu~tes or the safety precautio~ incident to th~ project.
CONTRACTOR/INSTALLER
Municipalily of Anchorage I
DEPARTMENT OF HEALTH & HUMAN SERvicEs
825 "L' Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
PERFORMED FOR:
LEGAL DESCRIPTION: ~'~
1
2.
4
5
6
7
8
9
10
[ "T~'~ ["' i ~'~"'~-' ( ~- DATE PERFORM
Township, Range, Section: "7'-/¢~/~! /~IA3/
SLOEE Sn'E PLAN
WAS GROUND WATER
ENCOUNTERED?
11
13-
14-
15-
16
17
18
19
2O
COMMENTS
IF YES, AT WHAT
DEPTEI?
Depth to Water Alter
M0r~ or no? ()[~V Date:
Reading Date Gross Net Depth to Net
Time Time Water Drop
$.,% --. ~ ,/V,. __
.w~ ~ ,, t ~., ye,,
:~ ~, - ~/~'. v~,'
:~3 ~ 5~'' ~&"
" ~ ~ 2 Y ~l~" ~ ,.
PERCOLATION RATE ~¢~- (m~nutes/mch) PERC HOLE DIAMETER __
TEST.U. aETWEEN_ ~ PTAND. /0 PT
PERFORMED BY: -(~ ~ -~ ~ f,~6~,,v ~Z .¢ ~ ~(~ I CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
October 31, 1994
Municipality of Anchorage
Division of Health and Human Services
825 L Street Suite 502
Anchorage, Alaska 99501
Attention:
Jim Cross
Program Manager - On Site Services
Subject:
Owner Installation Option
Replacement Septic System
Dear Jim:
S & S Engineering is preparing a construction plm~ for your review and approval to upgrade a
septic system on Lot 148C bordering the Old Seward Highway. My mother (Irene Hitchcock)
is the property owner. This plan should be delivered on November 1 to your office. A
preliminary copy is attached for your information.
As the season is growing short, I would like to request approval to install the system myself,
drawing on past experience of myself, my brothers, and my friends to assure a quality job. I
would reserve this owner installation permission as an option, as I am currently obtaining quotes
from experienced contractors to perform the work. I woukl ouly install the system myself if
these quotes are astronomically high or if the scheduling of existing projects is such that a
contractor could not guarantee completion of the work in a timely manner. Time is a factor
here not only due to the lateness of the season, but also the frequency that we are having to
pump the existing system. Currently we are pumping 2-3 times a month, a rapid increase in
frequency in just a few months.
I have I4 years of experience in the civil construction field (both municipal and private), and
have a wealth of family and friends with comparable experience. Some are experienced in
installation of new and replacement septic systems similar ~o the design that you will receive.
I know that we can perform thejob quickly and efficiently. Again, I am requesting installation
permission for myself mainly as a backup in case the contractor that we choose are not able to
perform the work in the time frame required.
If you have any questions, please don't hesistate to contact me at 345-3946 or 659-5000.
Sincerely,
November 3, 1994
Municipality of Anchorage
Division of Health and Human Services
825 L Street Suite 502
Anchorage, Alaska 99501
Attention:
Subject:
Jim Cross
On Site Services - Program Manager
Permissio~'~ for Owner Installation
Septic System Upgrade
Dear Jim:
Following our phone conversation of yesterday, I would like to provide more information about
my request for permission to owner install the septic upgrade on Lot 148C on the Old Seward
Highway, owned by my mother, Irene Hitchcock. As mentioned in my previous letter, I am
requesting this approval due to the lateness of the season as an option in case of scheduling
conflicts.
Any work done by myself will be closely monitored and will follow the specifications required
by the system engineer and the upgrade permit. The people that would perform the work are
very experienced equipment operators, with numerous years of backhoe experience (large and
small) in gold mines, highway construction, residential construction, landscape work and on the
North Slope. None of them are currently operating a construction and/or excavation business
in Anchorage, and will be working on this project purely as a personal favor. The equipment
used will be rented from somewhere such as Stephans Rentals, Baileys Rent-All, or NC
Machinery. I have extensive experience in the surveying field and will be on hand during the
project to layout the system, check grade, assure proper setbacks from the property lines and
wells, coordinate the engineering inspections and monitor the backfill and final inspection
efforts.
If you have any questions or com~nents, please feel free to call me at 345-3946.
Sincerely,
MUNICIPALITY OF ANCHORAGE
r��
Development Services Department �\`_ Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel]. D. 018-292-64-000
Legal description T12N R3W SEC 33 LT 148C
Expiration Date:
Site address 15021 OLD SEWARD HWY Anchorage AK 99516
Current property owner(s) PERMAN MATTHEW & ANNA R
6/20/2025
X The On-site system(s) is/are approved for 4 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
Original Certificate Date: 11/6/2024
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory x
Tank Age Advisory Arsenic Advisory
Other
COSA Approval_June 2022
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 018-292-64
Complete legal description T12N R3W SEC 33 LOT 148C
Location (site address) 15021 OLD SEWARD HWY, ANCHORAGE, AK 99516
Current property owner(s) MATTHEW & ANNA PERMAN Day phone
2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS
3. TYPE OF WATER SUPPLY: ® Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ❑ Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ❑ Steel ® Plastic ❑ Concrete ❑ Fiberglass
Age NEW - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ® Deep Trench ❑ Wide Trench ❑ Seepage Pit
Waiver request for:
Expedited review requested: ❑
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee U Waiver Fee $
Date of Payment C / /Z --j Z Date of Payment
COSA # �S C L y/ 4 3 z Waiver #
COSA Application.doc
COSA Checklist.docx
COSA Checklist
Legal Description: T12N R3W SEC 33 LOT 148C Parcel ID: 018-292-64
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled UNKNOWN Total depth UNK ft
Cased to UNK ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) 24 in.
Date of flow test for COSA 6/20/24
Static water level at beginning of test 88 ft.
Well production at time of test 3 gpm
Water storage tank volume NONE gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic 9.08 ug/L Arsenic less than MRL (ND)
Collected by Date 6/20/24
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in septic tank *NEW
Date of pumping NEW DEEP BURIAL
Required maintenance completed, if AWWTS
Comments: *NEW 1500-GAL HDPE TANK
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed) 12/1/94
ALL standpipes present per record drawing
Total measured depth from grade 15 ft (max)
Measured depth to pipe invert from grade 8.7 ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes (MT) go to bottom of effective. (ED)
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced 2000 gallons 6/19/24 date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date 6/20/24
Results Pass
Fluid depth prior to test 0 in
Water added 1250 gal
New fluid depth 1 in
Elapsed time 20 min
Final fluid depth 0 in
Absorption rate 600 gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) 72 in (MOA 6’ ED)
Effective depth used 0 in (Final Fluid Depth)
Effective depth (ED) remaining 72 in
Comments/Deficiencies: Approximate total measured depths from existing grade. ED per elevation measured shots &
appears approximate.
COSA Checklist.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date 10/17/2024
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &
10/17/24
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
On -Site Water and Wastewater Section
www.muni.org/onsite
I 907-343-7904
/ Fax: 343-7997
Nitrate Advisory
Certificate of On -Site Systems Approval # OSC241432
Subdivision: T12N R3W SEC 33, Block: , Lot: 148c
A water sample revealed a nitrate concentration of 9.08 milligrams per liter (mg/Q.
The Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While
private wells are not subject to this regulation, EPA standards are based on existing
health information and can therefore be used to gauge the relative quality of water
from private wells. Since nitrates are known to slowly increase, we recommend
you monitor the water quality. Please see the attached "Nitrate Fact Sheet" for
important information regarding nitrate.
This advisory must be attached to all copies of the subject Certificate of On -Site
Systems Approval.
Nitrate Fact Sheet
From Northern Testing Laboratories, Inc.
Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate
is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells.
SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of
ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the
oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners,
food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil.
TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is
associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of
young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood
stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry
oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the
concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered
from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization.
TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home
water treatment systems such as softening or iron filtration does not readily remove nitrate. The best
method for limiting nitrate in well water is source control. This can include avoiding overdosing of
fertilizer near the well and maintaining good separation distances between septic tank leach fields and
the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged
ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate.
TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a
spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect
the activity of nitrate in water. This laboratory uses several different wet chemical methods approved
under the public water supply laboratory certification program. They also have test kits available, which
the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can
monitor the change in nitrate levels from their well. They recommend comparing the test kit results
against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend
using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples.
Qi
ANCHORAGE RECORDING DISTRICT, ALASKA
AS -BUILT OF:
BLM LOT 148C
T12N R3W Sec33 S.M. PLATS 79-140 & 99-80
SURVEY•CERTIFICATE: I, John L. Schuller, Have conducted a
physical survey of this property as shown on this drawing and that the
improvements situated hereon are within the property lines and no
enchroachments exist other than noted. Under no circumstance shoulc
any information on this drawing be used for construction of fences,
structures, improvements, or for establishing boundary lines.
EXCLUSION NOTES: It is the owners responsibility to determine
the existence of any easements, covenants, or restrictions which
do not appear on the recorded subdivision plat.
WORK ORDER NUMBER: DATE: SCAM. E -MAIL -
AUG 10, 2024 1 "=30schullerakOgmail.com
24-070-2 DRAWN BY: CHECKED BY GRID NUMBER: BOOK AGE:
JLS SW3134 240274
s89°59'30"W
WIL.DIEN DRIVE
* = FND 5/8" REBAR
SUR
AMW
d/00,
�...........4....... .......... � Zr
� n
.,,....i...................:....�
'•.JaHN L. SCHULLER.•
LS --104080%
�f S ww► j • .. x
/' 1831 Talkeetna Street
icy �• . { to:Anchorage, Alaska 99508
o .®r
�► ° f e ©\ \. ,,■• (907) 227--1455 office
� l sslc n•a�► (907) 274--4992 fax