MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP231288
Work Type: SepticTank Upgrade
Tax Code Number: 01828201000
Site Legal Address: T1 2N R3W SEC 33 LT 169 G:3135
Site Mailing Address: 3450 SHANDY CT, Anchorage
Owner: CLADOUHOS JOEL & GRETA
Design Engineer: GARNESS ENGINEERING GROUP LTD
This permit is for the construction of:
Effective Date
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
O�',A�: is �` �•'Sn
I .I■ J
Uepai,tnlent
9/15/2023
9/14/2024
108900
❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
C' r
Received By: � ✓ �`� � G
Issued By:
Date:
Date:
MUMUPAUTY OF ANCHORA, GE
�. _�. •fin--''---^``-`-�s-.':'r_ _ „_ ..,. __ _'_..., _
Develo meat Services Department �'
P P °� =:= Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 018-282-01
Property owner(s) ERIC HAAS
Mailing address 3450 SHANDY COURT *ANCHORAGE, AK
Site address 3450 SHANDY COURT *ANCHORAGE, AK
Day phone 907-230-0941
Legal description (Sub'd., Block & Lot) T1 2N R3W SECTION 33 LOT 169
Legal description (Township, Range & Section)
Lot Size
Sq. Ft.
APPLICATION IS FOR:
(® all that apply)
Absorption Field ❑
Septic Tank
0
Holding Tank
❑
Privy
❑
Private Well
❑
Water Storage
❑
Number of Bedrooms 4-5BEDSEPTIC
APPLICATION IS AN
Initial'
Upgrade
Renewal
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
TYPE OF DWELLING:
Single Family (SF) 0
(w/wo AD U)
Duplex (D) ❑
Multiple Dwellings ❑
(SF and/or D)
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 2
Date of Payment: S(I T9 207
Receipt Number:CIS
Permit No. / Z
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\ Forms\Client Forms\Permit ApplicationAm
rel
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231288, Curtis Townsend, 09/15/23
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231288, Curtis Townsend, 09/15/23
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP231288, Curtis Townsend, 09/15/23
(~ MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL: INSPECTION REPORT
NAME' PHONE__ [] NEW
MAILING ADDRESS
LEGAL DESCRIPTION
LOCATION NO, OF BEDROOMS
I Well '' ~Absorption~,ea Dwell~n~g; PER~ITNO, --
p Z Manmfac[urer~f= C~ MateriaJ~ N No. of compartments
'~ O O IF HOMEMADE:
~ ~ DISTANCE TO:
~ DISTANCE TO: W0tl ~ ~O Foundation ~O Nearest lot line PERMITNO.
~ - ¢~ Mater~ beneath tile Total effective absor,tion area
OTHER
PiPE MATERIALS
SOIL TEST RA~I G
INSTALLER __ _
APh~VED ~ DATE LEGAL
72 013 (Rev. 3/78)
MUNICIPALIIY Ur ANUHUKA~
Department ~ Health and Environmenta? '~rotection
825 ~ Street, Anchorage, AK.
264-4720
* * * HANDWRITTEN PERMIT * * *
Permit ~ ~l/~o<~ ~C-L~L~AND/OR ON-SITE SEWER PERMIT
Location: Phone Number:
Legal Description:~F/~3~c~% ~T/6~ LOt Size:
Type of soil Absorption System Is:
Trench: y,. Drainfield:
~aximum Number of Bedrooms:
Seepage Bed: Holding Tank:
Soil Rating(sq.ft/br)
SWP/024 (1/81)
% The Required Size of the Soil Absorption System Is:
DEPTH ~) _.LENGTH /5~(~J) GRAVEL DEPTH ~ WIDTH '~(~)'-/-
The length dimension is the length(in feet) of the trench or drainfield. The
depth of a trench or pit is the distance between the surface of the ground and
the bottom of the excavation(in feet). There is no set width for trenches.
The gravel depth is the minimum depth of gravel between the outfall pipe and
the bottom of the excavation(in feet).
~DDA~* REQUIRED SEPTIC~:~-~4~) TANK SIZE = ~-'OO GALLONS * *
Permit applicant has the responsibility to inform this department during the
installation inspections of any wells adjacent to this property and the number
of residences that the well will serve.
· * * TWO(2) INSPECTIONS ARE REQUIRED * * *
Backfilling of any system without final inspection and approval by this department
will be subject to prosecution.
Minimum distance between a well and any on-site sewage disposal system is 100 feet
for a private well or 150 to 200 feet from a public well depending upon the type
of public well. Minimum distance from a private well to a private sewer line
is 25 feet and to a community sewer line is 75 feet. Well legs are required
and must be returned to this department within 30 days of the well completion.
Other requirements may apply. Specifications and Construction diagrams are
available to insure proper installation.
· * * PERMIT EXPIRES DECEMBER 31, 1 9 8 2 * * *
! certify that:
(1) I am familiar with the requirements for on-site sewers and wells as
set forth by the Municipality of Anchoralge.
(2) I will install the system in accordance with codes.
(3) I understand that the on-site sewer system may require enlargement if
the res ifence is re~odeled t2 include moire thDt ~ bedro9~.,,
Ap{licant ~~p ,,~ ~, ~/b~ Date'/ . ?: F)/"~,.q) ~/ /$~_"
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL pROTEC-FION
825 L. Street, Anchorage, Alaska 99501 264-4720
SOILS LOG - PERCOLATION TEST
SOILS LOG
PERCOLATION
TEST
7
8
9
10
11
12
13
14
15
16
17-
18
19
2O
DATE PERFORMED:_
SLOPE
SITE PLAN
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
"©',,, 'F~,-c ~¢, 3'/Z''
Gross Net
Readin9 Date Timo Time
~ ~o~ ~o
5 ~o:~ .~
Depth to Net
Water Drop
,Sfi
PERCOLATION RATE ____ 2.CJ (minutes/inch)
72-008 (6/79)
GR':&TER ANCHORA~b AI,[~A ~m(u~ ~n
HEALTH DEPARTMENT
327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511
T
INSPECTION REPORT ON-SITE SEWAGE DISPpSAL SYSTEM
SEPTIC 'rANK:
DISTANCE FROM WELL_
LIQUID CAPACITY '~'~
~-~__ , .COMPARTMENTS
GALLONS. ~NSIDE LENGTH .... INSIDE WIDTH. DEPTH__
SEEPAGE SYSTEM: SEEPAGE Pti:
NUMBER OF PITS _
LINING MATERIAL .
NEAREST LOT LINE_
OUTSIDE DIAME~ OR WIDTH
~,~ DISTANCE FROM WELL_
TOTAL EFFECTIVE ABSORPTION AREA (WAIL AREA)_
lENGTH_ DEPTH.
BU1LD~NG FOUNDATION
SQ. Fl.
TILE DRAIN FIELD:
!
D,S~ANCE PRO*,' WELL--/''5~¢
NUMBER OF LINES _ '~
ABSORPTION AREA ,.~/'~ __ SQ. FT.
DEPTH: TOp OF TILE TO FINISH GRADE_ ~,~ I
WELL:
LOT LINE
FOUNDATION___
DISTANCE BETWEEN LINES ~ ~ TRENCH WIDTH ~/~ IN. IOTAL EFFECTIVE
~ D~S~c~ :~o~ /~ ~ WA~:~ ~ ~A~:S~
~SAMPLE ,
NEAREST
DISTANCES:
GREATEK ANCHORAGE AREA ~)ROUGH
HEALTH DEPARTMENT ;.~:~
t 327 Eagle St. Anchorage, Alaska 99501 ,. 279-2511
SEWAGE DISPOSAL SYSYEM - APPLICAI'ION & PERMIT
NAME OF APPLICANT~'~ 0
RESIDENCE ADDRESS ~) ~1~
LEGAL DESCRIPTION
APPLICATION TO INSTALL: SEPTIC TANK
TO SERVE THE FOLLOWING FACILITY.
L ~ ^]~.. LOCATION OF INSTALLATION. ~%'~ L)t~(-~) ,~lq~[J
, SEEPAGE PiT_ ;DRAIN FIELD_. , OTHER
E,NANCED T,R0 GN
TO BE INSTALLED BY._ ~-, i C ~/k.)~ ~'-- ~
ANmmTED OATE GF COMPLE'rmN. ~:~')~ ]'} t" A)O
t I aln familiar with the reqt kements of Greater Anchorage Area B, prough Ordinance No. 28~6~and thgt the
I certify tha ...........
above described system is m accordance wire sam corm.
BELOW TO BE FILLED OUT BY HEALTH DEPAOTMENT
AS DESCRIBED BELOW, SIZE OF UNITTO RESeRVEDlY,
_. SEPTIC TANK SIZE./~ ~ ~) TYPE ~,f . SEEPA6E AREA. TYPE
DI~6~I OF SYSTE~
GR':&TER ANCHORA~b AI~ ~t~m(u~ ~n
HEALTH DEPARTMENT
327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511
T
INSPECTION REPORT ON-SITE SEWAGE DISPpSAL SYSTEM
LOC^TIONSN'0W '+t LEG=
SEPTIC 'rANK:
DISTANCE FROM WELL_
LIQUID CAPACITY
~__ , .COMPARTMENTS -
GALLONS. ~NSIDE LENGTH .... INSIDE WIDTH. DEPTH__
SEEPAGE SYSTEM: SEEPAGE Pti:
NUMBER OF PITS _
LINING MATERIAL .
NEAREST LOT LINE_
OUTSIDE DIAME~ OR WIDTH
~,~/ DISTANCE FROM WELL_
TOTAL EFFECTIVE ABSORPTION AREA (WAIL AREA)_
lENGTH_ DEPTH.
BU1LD~NG FOUNDATION
SQ. Fl.
TILE DRAIN FIELD:
DISTANCE FROM WELL--/
NUMBER OF LINES _
ABSORPTION AREA ,.~ __ SQ. FT.
DEPTH: TOp OF TILE TO FINISH GRADE_ ~,~ I
WELL:
LOT LINE
/' --, NEAREST LOT LINE __, OF LINES /~)
POUNDATION___ d~ // ~:~ ~- TOTAL LENGI~ ,~ ,
DISTANCE BETWEEN LINES ~ ~ TRENCH WIDTH ~J~ IN. TOTAL EFFECTIVE
NEAREST ~ SEPTIC ~1 SEEPAG: ~ ~ I ~'
s~w:~ u~:_ ~.~A~:%'I . SVS~:~ ~-~_ _ C~SSPOO~ sou~c~s~
DISTANCES:
//-7
· ! - HEAL]II
ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of thi
Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is sar(
functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify th~
based on the information obtained from the Municipality of Anchorage files and from my investigation an
inspection, the on-site water suppl~ and/or wastewater disposal system is in compliance with atl Municipal an,
State codes, ordinances, and regulations in effect on the date of this inspection.
Name of Firm ~'~'~" -~ c: Telephone
6. DHHS APPROVAL ~ /~¢..
Approved for ~-.~ bedrooms b / ' '
Approved ~isapproved Conditional
Terms of Conditional Approval
Date
5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this
Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe,
functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that
based on the information obtained from the Municipality of Anchorage flies and from my investigation and
inspection, the on-site water suppl~ and/or wastewater disposal system is in compliance with atl Municipal and
State codes, ordinances, and regulations in effect on the date of this inspection·
Name of Firm /~¢~-~C_C ~ (: Telephone
6. DHHS APPROVAL ~ /~.¢..
Approved for %.G bedrooms b / ' '
Approved ~isapproved Conditional
Terms of Conditional Approval
Date
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval
cerificated based only upon the representations given in paragraph 5 above by an independent professional engineer
registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DH HS do not conduct inspections
or analyze data before a certificate is issued. The Mun icipality of Anchorage is not responsible for errors or omissions
in the professional engineer's work.
72 025 (Rev 7/88)8ack Page 2 of 2
MUNICIPALITY OF ANCHORAGE i
Department o! Health & Human Sen~ices
DIVISION OF ENVIRONMENTAL SERVICES
343-4744
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF
ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING
Parcel i.D. # _~/-') \ O-r~, ~ r.~ ~ ~'~ - ~) \ HAA# ~'/ /'~
1. GENERAL INFORMATION (Must be completed prior to submittal)
(a) Legal Description (include lot, block, subdivision, section, township, range)
Location (a'4t '~ss or d r.e, ctions}
- ; ' ' ' $ ~F - p/o/
Prnnertv ~'¢~e~' ~J~'~'~'~r~4'~ ~' ~r Telephone: (home)
(c) Lending Institution,_. ' :,~ Telephon~
Business
Mailing Address
(d) Real Estate Company and Agent /o ;/'6/,d ~-~
Address
Telephone
(e) Mail the HAA to the following address: (or check here,i~a~', if hold for pick up.)
List contact person and day phone number below:
2, TYPE OF RESIDENCE
Single-Familyjg] Number of bedrooms
3. WATER SUPPLY
Individual Well,~ Community [] Public []
Note: If community well system, must have written confirmation from the State Department of Environmental
Conservation attesting to th legality and status.
4. SEWAGE DISPOSAL
On-site ~ Public [] Community [] Holding Tank []
Note: If community well system, must have written confirmation from the State Department of Environmental
Conservation attesting to the legality and status.
72-025(Rev ?/88) Page 1 of 2
5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my sea[ affixed hereto and as of the validation date shown below, I verify that my investigation of this
Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe,
functiona .and adequate for the number of bedrooms and type of structure indicated herein. I further verify that
based on the information obtained from the tvlunicJpaJity of Anchorage files and from my investigation and
inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and
Stats codes, ordinances, and regulations Jn effect on the date of this inspection.
Name of Firm /~--~"-¢ -/~- Telephone
Address ~¢ ~ ~¢¢~ ~~ ~
/ /
~. ~~al_/
6. DHHS APPROVAL
Approved for
Approved / . Disapproved Conditional / .
Terms of Conditional Approval
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval
cerificated based only upon the representations given in paragraph 5 above by an independent professional engineer
registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements, Employees of DHHS do not conduct inspections
or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions
in the professional engineer's work.
72-025 (Rev. 7/88) 8ack Page 2 of 2
MUNICIPALITY OF ANCHORAGE (MOA)
Health Authority Approval (HAA)
CHECKLIST - FEBRUARY 1984
343-4744
Legal Description: "'T"'/,~A)
A. WELL DATA
Well Classification pr/ ,'~[-¢ If A, B, C, D.E.C. Approved (Y/N) ~'
Well Log Present (Yi~)~ _._D ate Completed "" I??R Yield
Total Depth ~' ? Cased to ~2 _Depth of Grouting ~'~ .
Static Water Level
Casing Height Above Ground
Electrical Wiring in Conduit (~)
/¢/
SEPARATION DISTANCES FROM WELL:
To Septic/Holding Tank on Lot /
To Nearest Edge of Absorption Field on Lot
To Nearest Public Sewer Line ,_ /U/~}
To Nearest Sewer Service Line on Lot
Water Sample Collected by
Water Sample Test Results
Comments 7~,~ [5__ Iv-g//
_ To Nearest Public Sewer Cleanout/Manhole
Sanitary Seal on Casing ~N)
Depressi°n Ar°und Wellhead ~(N) ~,
; On Adjoining Lots
; On Adjoining Lots
B. SEPTIC/HOLDING TANK DATA
Date Installed IZ-/J/,C~_Size ~..~0 ~¢2 No. of Compartments
Standpipes (y~, N) _~Air:{i~'ht'~s~Ni _- -"% Foundation Cleanout C/N)
Depression over Tanl<(~;)N)/~l(~· )Oate Last Pumped , ,5~'/,,~/~,¢'
Pumping/Maintenance Cor~.ct on FC~lil~ ~Y~N?'/~L/¢/ ;,,~ _;for
Holding Tank High-Water Alarm (Y/N) ~- Temporary Holding Tank Permit (Y/N)
ScEPARATION DISTANCES FROM SEPTIC/HOLDING TANK:
.~-o Water-Supply Well l ~
,!i To Property Line ,5'~ ¢/ ~
To Water Main/Service Line ~ ~ /
To Stream Pond, Lake or Major Drainage Course ,.,.b /¢0 /
To Building Foundation ,5'"¢ ~ ~
To Disposal Field // /
Com.ments
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed ! ~-/$/'8' ~
Width of Field ,cc- /
Square Feet of Absortion Area
Depression over Field (Y/~
Results of Last Adequacy Test
Type of System Design
Length of Field /
Depth of Field
Gravel Bed Thickness /
Statndpipes Present ((¢~/N)
Date of Last Adequacy Test
SEPARATION DISTANCE FROM ABSORPTION FIELD:
To Water-Supply Well
To Building Foundation
Lot
To Water Main/Service Line
To Stream, Pond, Lake, or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area
Comments
To Property Line 21~ /
To Existing or Abandoned System on
; On Adjoining Lots ,P
~, 5-0" To Cutback (if present)
'~ loel
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Dimensions
M a n h o I e/A c c e~.(N'/)~'~
"Pg~p~'f" Level at
A) /,/~>.. ~¢'~ Vent (Y/N)
Meets MOA Electrical.~~
Comments .
Pumping Cycles during Adequacy Test.
inspection.
Signed
Company
Date
MOA No.
**Check Permitted Bedroom Rating Against HAA Request**
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this
ReceiptNo. c::~/ ?' "~ ~ ¥7; ~ ~ ) ReceiptNo.
Date of Payment -~ -,--.~ - '~ C~ Waiver Fee: $
Date of Payment
~-o~ (R~ 7/~)~o~ Page 2 of 2
IJEI-t~.I~,II'I(:I Il' IIkAL.{II AND
825 ~, Stsc'et, Anchorage.',. Alas,la
Insp Jken ~ ~dy
Date Roeeived:
Time
Date
PROTEc:FION '{'~' ~'"
99501
September ] 3, 1977
Da he
Insp ........... tnsp
REQUEST FOR APPROVAl, OF INDIVIDUAL SEWER AND WATER FACII,I'i'IES
Lending Institution Request: Alaska U.S.A. Federal Credit Union
Hailing Address:I 777 Juneau 8kree¢ 99501 Pheue: 276-645d
Property Owner:
I4ailJ. ng Address:
Barbara J. Wilkinson
1410 West 27, Apar%ment 15
Phone: 278-2027
Legal },~scri }tion- T12N R3W Section 33 Lot ] 69
Single ?emily Residence:
Nu]tiple Family Residence
Number of Bedrooms: Five
Numbe] of Bedrooms:
5. Well System: Individual Well ~'. ) Commun[ky/Pub].ic System ( )
Permit: I! Depth of Well 67' well Log on ]:'Ale ( )
Construction __~)~zpt~?l ......... Bacterial Anal ysis ,.l_~l__~m .o_L'£1-¢ ,~
Sewage Dispesal System: On-site System (x) Public Utility .( )
Permit ~i
Septic Tank Size
Absorption Area
Installed 1970 In,~.a].le~.
P~anu lecturer
Soils Rate
Haterial
Distances: Well to Septic Tank
to Sewer Line Nearest Lot.
ho Nearest Lot Line
line
tO Absorption Area
~ ........... AbsorptJ on Area
MUNICIPAEITY OF ANCHORAGE
DEPARTMEN'r OF HEAL'Tlr84 ENVIRONMENTAt. PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Streel · Anchorage, Ah~skr~ 99501 Tolephon0 264-4720
CE,~tTIFICATE OF INSPECTION
SEWER AND WATER FACILITIES
1. PROPERTY OWNER
Thomas/Alia Schmidt
SEar Rout_e A Box 485W 9950?
2. LEGAL DESCRIPTION
{].2:1 R3N Section 33 Lot 1. o9
3. 'IYPE DWELLING
.tiE*:, SINGLE FAMILY RESIDENCE Eli OTHER (Describe)
E2 MUI_IIF'LE FAMILY RESIDENCE
4. WATER SUPPL\'
-~,*( INDIVIDUAL
El] COMMUNITY/PUBLIC
5, SEWAGE OISPOSAI.
:Jig.::': INDIVIDUAL/ON SITE
Il PUBLIC LJTILtTY
[l-'J HOLDING TANK (Maintenance Required)
:'(~ APPROVED FOR.~_~.~ ........ BEDROOMS
~_] CONDITIOr4AL APPROVAL (See Attached)
,r ,~ DISAPPROVED
! DATE RECEIVED
INsPEcTION APPOINTM, ENTS
TIME TIMEi ~ TIME
INSPECTOR INSPECTOR INSPECTQR
., ....
MUNICIPALITY OF ANCHORAGE
) DEPARTMENT OF HEALTH & ENVIRONMENTAL PRoT~ALI~ OF ANCHORAGE
825 L Street - Anchorage, Alaska 99501
ENVIRONMENTAL SANITATION DIVISION
Telephone 264;4720 M~ ~ ~ l~J~0
DIRECTIDNS: Compiet0 all parts on page 1, Incomplete requests will not he processed, Please allow ten (10) days for processing,
1, PROPERT~WN~R PHONE
PROPERTY RESIDENT (If dif~er~nt from above) / r f PHONE
2. BU FE -
MAILI ~G ADDRESS
MAILING ADDRESS
4. RE~L~OR~AGENI' , ~ -- - j PHONE
~AILI~6 ADDRESS f f
B. LEGAL OE~CRi 3TiON : '
I~, TYPE OF RESIDENCE ' NUMBER OF
~ Two
~ MULTIPLE FAMILY /~- ~ Three
7. WATE~PPLY
~ INDIVIDUAL*
~ COMMUNITY
PUBLIC UTI LITY
8, 'SEWA~E~ISPOSAL SYSTEM
~ INDIVIDUAETON-SITE~
½EDROOMS
i~. Four [] Other
Five
[]
* ATTACH WELL LOG. A w~ll log is required for all wells drillecl
since June 1975. For wells drilled prior to that date, give well
d0pth (attach log if available.) ~'~ '~,) ~
/ ~ ? ~'~ .YEAR ON-SITE SYSTEM WAS INSTALLED.
[] PUBLIC UTILITY
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010 (Roy. 6/79)
THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE NUMBER OF BEDROOMS
[] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
PERMIT NUMBER
2, WATER SUPPLY
[] INDIVIDUAL DEPTH OF WELL
[] COMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG RECEIVED
3, SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
E~]INDIVIDUAL/ON -SITE DATE INSTALLED
[]PUBL,C U IL,TY G
Connection Verified ·
INSTALLER
[]Septic Tank or []Holding Tank
Size:-./~"~ - If Tank is homemade
SOILS
RATING
give dimen~iO'ns:
TYPE OF TANK MANUFACTURER ~----7__~AA , , ._'.
TOTAL ABSORPTION AREA MATERIAL ~,
~ J ' Nearest Lot Line
4. DISTANCES Septic/HoldingTank Sewer Line
WELLTO: /~-~'
Absorption Area to nearest Lot Line
5. COMMENTS
~'~'APPROV ED FOR ~" BEDROOMS
[] CONDITIONAL APPROVAL (letter must accompany certificate)
[] DISAPPROVED ~
DATE
72-010 (Rev. 6/79)
April 4, 197,0
?boreas/Alta S d-mil{it
Anchor~gg, AJ..aske 99507
Su. bject: 'lq.2/! R3','! Sec',tio~l 33 Lot 16!)
Al~}?roval for your individual sew,ar and w~¥ger ~acilitios
ca~ not be granted until th~ following items havn been
r3ompleted ~
(!) ~'~'~ water analvs] ~ repor~ be deliver~d tO tills
[ ;~fl(~e frol~ Ch~RI t, ab~ b633 .~3 ~'{.Ieet~ roi ou~
~ review. ,
'~ (2~ 'l'he septic 'ban];. put, ti)ed v~J.tt~ a reGeipt sttbn~ltted
~ ~ ' tO 'iq~JS office.
(3) An adequa~y test be performed, on the ~,i{istJ. ng
~ lea(]hin~i area. '.]~]%Jo~ test wi],l cleter~line if thn
'/ A ll~ting of private firms pezforming 'th(, test
is enc]_osed~ ?his report needs to be submitted.
to this ,'{epartment for our r,~view~ ~
if there are any f~z-Lher qt%estions, pl~.~ase contact this
offico at 264-4720,,
As~oc:iate SpecJ alist.
4619 Spe};ard Road 99503
Tobben Spurkland
8155 Cranberry St.
Anchorage, Alaska 99502
Phone (907) 243-5302
Mr. Jim McCourt
Yukon Realty
4619 8penard Rd.
Anchorage, Od. asks 99503
April 13,
1980
SEWER ADEQUACY TEST
LO T I 6 9 , SEC. 3 3 , T I 2 N, R~ W
Residence:
Water
Sewer
Date of ].est·
Test Procedure:
2 storey, single family, full basement, 5 bedroom~~'
On site well
From Municilml records: Installed in 1969
Tank: 1250 gal. concrete, Espifioza
Drainfield: 4 lines total length 190 fe~t,
No cleanouts or observation pipies
April 10, 1980
On inspection tank was fgund full and the following measurements
were taken~ ~
Distance to tank bottom; 8'~8"
Distance to bottam of stand pip~; 2~-7''
Depth of tank: ~'~1"
Water at the rate of 4 gal. per miniute was introduced into
the system via a tub in the basement and the following
rea~ings 9f the waterlevel in .the tank taken. ·
D is distance to water surfac~ using t~e stand pipe as ref.
Time Del. t Del Q D! Del D
9.40 0 0 41~ 0
9.45 5 ~0 41~ ~
9.50 5 20 39~/4 1~
9.55 5 20 38~ 1~
~O.00 5 20 37' 1~
10.02 2 8 3~ 3.75
10.O3 Water shut off ~
Disregarding outflow every 20 gal caused a 1/* inch raise in
the tank. This checks with the stated volume if the tank.
Absorption Rate:
The house water was shut down for 60 min. and the following
readings of the water surface level of the tank observed.
Tobben Spurkland P.E.
J~ McCourt
Yukon Realty. April 13, 1980
Time Del t D de D Del Q
10.30 28 39 5.75 28
10.45 15 39.5 0.50 8
11.00 15 40 0.50 8
11.15 15 4o.5 o,5o 8
11.30 15 40.75 0.25 4
5.15 41.25
These readings show that the system is absorbing
32 gal per h~ur or 768 gal per 24 hour.
The municipal requirement for h 5 bedroom house is
750 gal per 24 hottrs. ~
These observations show that the syst~ is operating in a
overloaded mode. This may be caused by faulty installation,
saturated ground, high water table, or by the sytem having
reached the end of its operatihg life o During the test both
the inlet pi~ and the outlet pipe of the septic tank were
submerged, and at one )~int of the test water was raising
in the standpipe which shows tat water was being stored
in the house sewer line.
If this backup is caused by saturated ground, overloading
and poor operation of the system can be expected during
breakup and in periondssofheavy rain.. If the problem is
caused by faulty inst~llation or because the end of the
life of the system is appraaching~the problem of proper
operation will become progressively worse and ultimately
require replacement of the system.
This system was tested by R&M Engineers in Oct. 1977.
t~M measured an absorption rate of ~6 gal per hour,
however, the system was tested twice, presUmably because
'the first test indicated the system was failing.
CONCLUSIONS:
The system meets the municipal!absorption requirements.
[~oblems must be expected during breakup and during
periods of heavy rain~
The system is 11 years old,' itlshould not be expected to
last more thdn 5 more years.~
Note. The stand pipe to the septic tank is loose and should
be replaced.
kobben opurkla~l l°.F,.
III: Time
Date
Insp
DEPARTMEN'
825
MUNICIPALITY OF ANCHORAGE
)F ltEALTII AND ENVIRONMENTf
L Street, Anchorage. A]iaska
264-4720
Date Received:
PROTECTION
99501 .~
13, 1977
10:30 a.m. #2: Time #3: 'rime
9-~77 ~amh~; ~]x~,%. Date Date
Jkennedy Insp Insp
REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES
Lending Institution Request: Alaska U.S.A. Federal Credit Union
Mailing Address: 777 Juneau Street 99501 Phone: 276-6454
Property Owner: Barbara J. Wilkinson
Mailing Address: 1410 West 27, Apartment 15
Phone:
278-2027
Legal Description: T12N R3W Section 33 Lot 169
Single Family Residence: (~ Number of Bedrooms: Five
MultJ. ple Family Residence: ( ) Number of Bedrooms:
Well System:
Permit Il
Construction
Individual Well ~) Co~tlunity/Public System ( )
Depth of Well 67' Well Log on File
Bacterial Analysis
( )
Sewage
Permit #
Septic Tank Size
Absorption Area
Disposal System:
Installed
On-site System (~ Public Utility
1970 Igstaller
Manufacturer
Soils Rate Material
( )
Distances: Well to Septic Tank ~o Absorption Area
to Sewer Line Nearest Lot line Absorptioa Area
to Nearest Lot Line
.1UNICIPALITY OF ANCHORAGE
Department of Health and Environmental Protection
825 L Street, Anchorage, Alaska 9950].
264 - 4720
o
Property Owner: _, D zA~ ~., ~
Mailing Address: /~Z~ ~) A~ ~PI~'~-- Phone:
Mailing Address: _ff~ ~{~m~e' Phone:
Legal Description: 2A~- /$P X/~ ~iPZ{~ ~Y-b~
Single Family Residence: (~ Number of Bedrooms:
Multiple Family Residence: ( ) Number of Bedrooms:
7. Water Supply: *Individual Well (/~JPublic/Community System ( )
ill Ilndividual Well, well depth ~ ~
If Co~mnunity Syshem, name of system
8. Sewage Disposal System: On-sihe System (~ublic Sys'hem ( )
If On-sihe System, date of installation: ~ l.p'~
*NOTE: A well log is required on ALL wells drilled since 6/75.
3/77
Page
Two
Depar[ment of
Reques[ for Approval
IIealhh and Environmental Protection
of Individual Sewer and Water Facilities
Legal Description: T12N R3W Sec'hion 33 Lot 169
Comments:
Affadavit Attached: ( ) Letter Attached: ( )
S89059'1 9"E 329.53 7558C
SHANDY COURT o
33' Road Reservation co
�---- ----- Shed ------
I Storage
�j 04
_ coop--Q:.��cshalt ;.
EAST 329.47
NOTE: Bearings and distances shown Lot 184
hereon are record per adjacent
Plat No.84-260.
SCALE: V= 60'
EASEMENTS OF RECORD, OTHER THAN
THOSE SHOWN ON THE RECORDED
PLAT ARE NOT SHOWN HEREON
UNLESS OTHERWISE NOTED.
OFAW
•q��S
'`�Ir�.•• 49th.* 00
00 ....................... /
00
00
00
00 A'. Elizabeth L. Walatka : yf
�,s�F • • 8036 — LS
'�, • • C:;
op�� tai W
T4FgsSloNpA_ 'A 4►
FB 23-2, pg 28-29 BE
FB 77-6, pg 30
RECERTIFIED 8-03-23
AS -BUILT NO CORNERS SET THIS DATE
I hereby certify that I have performed a Mortgagee's inspection
in accordance with ASPLS Standards of the following
described property: LOT 169, SECTION 33,
T12N, R3W, S.M, AK
Anchorage Recording Precinct, Alaska, and that the
improvements situated thereon are within the property lines
and do not overlap or encroach on the property lying
adjacent thereto, that no improvements on the property lying
adjacent thereto encroach on the premises in question and
that there are no roadways, transmission lines or other
visible easements on said property except as indicated
hereon.
Dated at Anchorage, Alaska
this 26th day of September , 1977.
FRED WALATKA & ASSOCIATES, L.L.C.
907-248-1666 Engineers and Surveyors
This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary
survey and is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to
establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original
client or by others at a later date without the consent of Elizabeth L. Walatka is a violation of Federal Copyright law. Unless gross negligence is discovered,
the liability extent of the preparer is limited to the amount of fees collected for services in preparation of this product.
O
I
O N 2.3
O
I
9 2
ch
CC
I
e
^
M
222.
8.0 �
deck Z
?
7
W
Z
I
I
Septic vent (typ) l
o w
o deck
LO
Cj
o
I
LOT 169
3�0 9
r"
o
_
ti
W
I
:
o
0
� E
co
OIPhali
°
Z
Z
C0
�I
to
Z
I
-
CO
.
e40Y
60
e
Shed
-
I
I
- o Well
EAST 329.47
NOTE: Bearings and distances shown Lot 184
hereon are record per adjacent
Plat No.84-260.
SCALE: V= 60'
EASEMENTS OF RECORD, OTHER THAN
THOSE SHOWN ON THE RECORDED
PLAT ARE NOT SHOWN HEREON
UNLESS OTHERWISE NOTED.
OFAW
•q��S
'`�Ir�.•• 49th.* 00
00 ....................... /
00
00
00
00 A'. Elizabeth L. Walatka : yf
�,s�F • • 8036 — LS
'�, • • C:;
op�� tai W
T4FgsSloNpA_ 'A 4►
FB 23-2, pg 28-29 BE
FB 77-6, pg 30
RECERTIFIED 8-03-23
AS -BUILT NO CORNERS SET THIS DATE
I hereby certify that I have performed a Mortgagee's inspection
in accordance with ASPLS Standards of the following
described property: LOT 169, SECTION 33,
T12N, R3W, S.M, AK
Anchorage Recording Precinct, Alaska, and that the
improvements situated thereon are within the property lines
and do not overlap or encroach on the property lying
adjacent thereto, that no improvements on the property lying
adjacent thereto encroach on the premises in question and
that there are no roadways, transmission lines or other
visible easements on said property except as indicated
hereon.
Dated at Anchorage, Alaska
this 26th day of September , 1977.
FRED WALATKA & ASSOCIATES, L.L.C.
907-248-1666 Engineers and Surveyors
This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary
survey and is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to
establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original
client or by others at a later date without the consent of Elizabeth L. Walatka is a violation of Federal Copyright law. Unless gross negligence is discovered,
the liability extent of the preparer is limited to the amount of fees collected for services in preparation of this product.
' : · : : ' , : ' , ~ r ' ~a ' ; · AS.BUILT NO CORNERS SET THIS DATE
. ~-~ ..' ~ '.'~ ~a , s~c~on ~ the ~oHo~g des~ p~per~ ........ ,,
' ~', ~ : ~ ~ s .~, ' '
: : . ~, ~ ~ ~,~ Wo~atka ~ ~ not overlap ~ en~oad~ on the property lying a~3acent
· · ~ - ~ ~. , ~ ~ ~ · · to, that no ~provemen~ on prop~y lying adjacent thereto
~ . ~ o~> % ........ ~, .~.~ en~oa& on ~e ore~ses ~ question ~d that thee ~e no
~ · ' -~ P~OF~ .....~L~ ~ ' said prop~ except ~ ~dica~ hereon.
' [ - '' ~'~ ' Dated at ~orage, ~ka
THOSE SHO~N ON TH~ BEOO~DED F~ W~ ~ ASSOC~TES
P~T AR5 NOT SHO~N HEREON. Engineers and Su~eyo~
-2
'4
~ : . ... ..... .:. :::.:::
· : : ' ' ' : ; ':-": :'~ : : j : (V:- ~ ' ~ :
d",~ ~ _ ' _ ' : ' ' .' ':': ' ' t I : : V.6~ · i ' '
, · t I ................. l .... ~ ....
....... ~ .... . ~ ~ : ' j ~ '. ' '. : I ~ ~'~: ~:=~ ~: : .
...._, .- .... .....,_ ,~.~ ......, . . ,. ~ 'r'.. ~-/--,.' ,- ; -..- -:'--: -:=~:
· ~ . : , · : , , ~ . ; , "'l ~ ': I , ': ,~C 6~ ~ ~ , ' . · ; ·
, ~L,, ':'~ ;"~':.:~ :'' ~'' ~ ]:'~ ;:;'--j, ~ ,"~-:.-:~ : :,":~ ~~ ;:: :':.~W-~ ~ : ~ :~'..: '-;'. ~'
.... ; ' "i'~:~'~'~': .... ." ': '.'" :':'"': ~'L F~'":"; x -~ ~::'~)'~"': : :":"-'7 .... : ' " .....
~ ~' ]'~ ~ As-gu Il' · NO CORHEn8 SET '~ .S DATE
/ :~·
i : [ · . : .... ; ' ~. ¢'', ~,~ ~. /d'~ff - : to lhat no improvemenls on property lying adjacent
.{ ' [ · , - 4~ >~ % ~" ~<-~;~ ' ; . encroach on Ihe pren~ses m quesaon anp l),at tlc e .
-~D~ [ ' ' ' '~ ~ '*,.. ..~%% ~-'~ ' roadways tran:m xsion ]in~ or other visible
0527 -
~0. Dept, .Date_ ', '"
/ ,
Name - 4/, (~ '~._'~-' ~
~' SOLD BY CASH C.O. D,CHARGE ON ACCT, MOSL RETD. PAID OUT
QUAN. DESCRIPTION PRICE AMOUNT
5H 32
October 5, 1977
R&M No. 751529
Mrs. Barbara Wilkinson
1410 W. 27th Avenue, Apt. 13
Anchorage, Alaska 99503
Subject: Adequacy Test on Sanitary Sewer System, Lot 169, T12N, R3W,
Sec 33, Anchorage, Alaska.
Dear Mrs. Wilkinson:
On Septen~er 21, 1977, at your request, we conducted a test of the
septic system on the above described lot. This test is described in our
letter to you dated September 26, 1977. Due to heavy rainfall conditions
at that time, it was requested that we repeat the test, on a clear day.
We returned to the site to do so on October 4, 1977.
During the test, the liquid level in the septic tank was monitored at
regular intervals, through the standpipe, as water was added to the
system. The following table summarizes these measurements.
SUMMARY OF MEASUREMENTS
Time
Depth to Liquid Level
pelow Top of Standpipe
Water Meter
Reading in Gallons
9:38 5.40' 7757.0
9:45 4.50' 7782.0
9:51 4.30' 7797.0
9:56 4.50' 7797.0
10:06 4.95' 7797.0
10:15 3.75' 7837.0
10:31 4.95' 7837.0
The meter used during the test was a Rockwell 5/8" standard water meter
which had been previously calibrated by R&M Consultants, Inc.
The drawdown measurements indicate that the system'accepted 40 gallons
over a 25 minute period. The indicated effluent acceptance rate is 1.60
gallons per minute during the test.
Ass~ning that the five-bedroom residence on the lot will house ten
people, the average load on the disposal system can be expected to be
750 gallons per day or 0.52 gallons per minute.
October 5, 1977
Mrs. Barbara Wilkinson
Page -2-
As a result of the second test performed, it appears that the system is
performing adequately to meet the effluent demands of a five bedroom
house. It should be noted that the degree of saturation of the soil may
significantly affect the efficiency of this s~stem. Problems may occur
following spring break up or periods of heavy rainfall. It should also
be noted that the system has a fairly low surge capacity.
We appreciate this opportunity to be of service to you. Please contact
us if you have any questions concerning this test or letter, or if we
can be of additional service.
Very truly yours,
R & PI CONSULTANTS, INC.
Richard W. Burg, Jr.
Staff Engineer
Head, Earth Science Depart~nt
RB:JMB/rds
September 26, 1977
R&M NO. 751529
Mrs. Barbara Wilkinson
1410 W. 27 Avenue, Apt. 13
Anchorage, Alaska 99503
Subject: Adequacy Test on Sanitary Sewer System, Lot 169, T12N, R3W,
Sec. 33 SM, Anchorage, Alaska.
Dear Mrs. Wilkinson:
On Septer~ber 21, 1977 at your request, we conducted a test of the septic
system on the above described lot.
During the test, the liquid level in the septic tank was monitored
through the standpipe as water was added to the system. The following
table summarizes the measurements.
Time
Level of Liquid
Below Top of Standpipe
Water Meter
Reading in Gallons
1:42 5.45' 6964.0
1:52 4.5' 6989.0
2:32 5.35' 6989.0
2:35 4.7' 6999.2
3:10 5.25' 6999.2
3:25 3.9' 6999.2
3:40 4.75' 6999.2
The meter used during the test was a Rockwell 5/8" standard water meter
which had previously been calibrated by R&M Consultants, Inc.
The drawdown measurements indicate that the system accepted less than
0.5 gallons per minute between 1:42 and 2:32 and lens than 0.26 gallons
per minute between 2:32 and 3:10. This indicates ah average effluent
acceptance rate of less than 0.43 gallons per minute during the test.
An unexplained surge in the system occurred betweenl 3:10 and 3:25, when
the water level rose 1.35 feet. This could possibly have been produced
by a sump pump within the house or by groundwater entering the system.
It should be noted that the test was performed during an unusually heavy
rainsto~n.
The level of saturation in the leach field is not known since the
residence on the property was not occupied at the time of the test.
Assuming that the five-bedroom residence on the lot will house ten
people, tbe average load on the disposal system can be expected to be
750 galloas per day or 0.52 gallons per minute.
We conclude that the system in question is not perfornling adequately for
a five-bedroom house.
We appreciate this opportunity to be of service to you. Please contact
us if you have any questions concerning this test or this letter, or if
we can be of additional service.
Very truly yours,
R&M CONSULTANTS, INC.
Stephanie Hoag ~' Jim McCaslin Brown, Ph.D.
Staff Geologist Head, Earth Sciences Dept.
SH/JMB/mu