HomeMy WebLinkAboutBRATSLAVSKY LT 2su-aml 1 1 AL .IaN 0 2 2019 Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181249 PID Number: 018-322-42 ❑ New ✓❑ Upgrade Name: ROMAN & TANYA BRATSLAVSKY ABSORPTION FIELD ❑✓ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 15300 OLD SEWARD HIGHWAY ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 6 1.2 GPD/SF 17 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 9.0 Ft. Gravel depth beneath pipe 8.0 Ft. Subdivision Block Lot BRATSLAVSKY 2 Fill added above original grade 0.0 Ft_ Gravel length 50 Ft. Township Range Section Gravel width 1.5 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft_ SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 800 Ft2 1 N/AFt. Well 100+ 100+ N/A I N/A 100+ TANK El ❑ S.T.E.P. El Holding El Other Manufacturer ANCHORAGE TANK Capacity 2000Gal. I I Surface Water 100+ 100+ N/AI N/A Material Number of compartments Lot Line 45.3 33.1 N/A N/A STEEL 2 NA Foundation 13.4 10.0 N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain 50+ 50+ N/A N/A Gal. Remarks Pump on level at in. Pump off level at in. High water alarm at in. Pump make and model Electrical Inspections performed by Installer PIPE MATERIAL House to tank 3034 Tank to drainfield 3034 DOUG GREY Drainfield 3034 COIMT 3034 Inspector PANNONE ENGINEERING SERVICES BENCH MARK (Assumed elevation) 100.0 ft Inspection, dates: 1" 11/13/18 2"1 11/14/18 Location and description Sd 11/14/18 4"' 12/26/18 SW BOTTOM HOUSE TRIM COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp OF. Conditional Approval: Date . ,� 'CSGA. TH ...I`. tteven I�annoRe Approved mac, Date '( f? 17 1 C 8149 �t 0PR II J�PUU(IUII RCPUU_I-I-IL.UU(. DESIGN PARAM[�TERS E A UPGRADE SEPTIC SYSTEM ry NO. BEDROOM: 6(900 gpd; TANK SIZE: 2000g 41.9 —FC T1 24.2 PERC RATE: 3.2 MPI T2 SOIL RATING: 1.2 CPD/SF ROD: AREA 750 SF tl SYS. TYPE: DEEP TRENCH 8,0' ED w MIN LENGTH: 46,9 L, - USED: M2 50LFx1.5'Wx8.0' E.D., 17' TD 38�6 TOTAL AREA: 800 SF REMOVED i 500a EXISTING 74.5 SEPTIC TANK PER MOA CODE M3 1 69.4 10.5 INSTALLED 2000o SEPTIC TANK W/ FOUNDATION CLEAN OUT�� BEFORE AND DCO AFTER DCO k DRAIN FIELD E /o DECOMMISSIONED PER MOA CODE 10 /C� C5' T2 T TH - I M2 /� / INSTALLED DRAIN FIELD 50LF x 15W x 8.0'ED x 1 7.0'TD INSTALLED CO AND MT AT EACH END REMOVE AND REPLACE FOR RESERVE A B 21.2 41.9 —FC T1 24.2 47.0 T2 19,5 60.9 DCO 20.2 63.6 —C1 33.3 34,2 M 1 34.9 M2 —33.4 40.0 38�6 C2 74.5 13.6 M3 1 69.4 10.5 /C� C5' T2 T TH - I M2 /� / INSTALLED DRAIN FIELD 50LF x 15W x 8.0'ED x 1 7.0'TD INSTALLED CO AND MT AT EACH END REMOVE AND REPLACE FOR RESERVE z < o, od 2000g SEPTIC TANK CONNECTED TO CORNER OF TRENCH PROFILE SCALE: NTS �'w Z 100 DRIVEWAY C1 -TH-2 110 .0 '2 01.0 C 1 2 33' ROADWAY AND I Y UTILITY EASEMEN NND 'EL WITH NO AND WITH 2018 NOTES: Date RECORD DRAWING PA-MONE ENG SVC, LLC OF A .1 1/7/19 P.O. BOX 100217 ANCHORAGE, AK 99510 Scale PHONE (907) 272-8218 FAX (907) 272-8211 1 "=30 DRAWN BY: 4 TH ACP - P.J.D. NO BRATSLAVSKY, LOT 2 ...... .. .... -M-322-42 Steven Pannone PERMIT i ROMAN & TANYA BRATSLAVSKY IT No, CE 814 15300 OLD SEWARD HIGHWAY OSP181249 PLAN ANCHORAGE, AK 99516 Sheet lk�, 9?0FTESzrS1 2 OF 3 0 Z < U 0 z < u 0 z 0 < 2 0 n n z < o, od 2000g SEPTIC TANK CONNECTED TO CORNER OF TRENCH PROFILE SCALE: NTS �'w Z 100 DRIVEWAY C1 -TH-2 110 .0 '2 01.0 C 1 2 33' ROADWAY AND I Y UTILITY EASEMEN NND 'EL WITH NO AND WITH 2018 NOTES: Date RECORD DRAWING PA-MONE ENG SVC, LLC OF A .1 1/7/19 P.O. BOX 100217 ANCHORAGE, AK 99510 Scale PHONE (907) 272-8218 FAX (907) 272-8211 1 "=30 DRAWN BY: 4 TH ACP - P.J.D. NO BRATSLAVSKY, LOT 2 ...... .. .... -M-322-42 Steven Pannone PERMIT i ROMAN & TANYA BRATSLAVSKY IT No, CE 814 15300 OLD SEWARD HIGHWAY OSP181249 PLAN ANCHORAGE, AK 99516 Sheet lk�, 9?0FTESzrS1 2 OF 3 1 2 3 4 5 6 7 10 11 12 13 14 15 16 17 18 19 20 21 22 23 TEST HOLE 2 OR ORGANICS SMI BROWN SAND GM AND GRAVEL I WITH FINES IGRA SM/ I y SAND GM AND GRAVEL WITH FINES SOILS LOG - PERCOLATION TEST SLOPE --SITE PLAN TH- WAS GROUND WATER ENCOUNTERED? N IF YES, AT WHAT SM CLEAN SAND DEPTH? -DRY DEPTH TO WATER AFTER MONITORING? -DRY DATE: 11/13/2018 BOH DATE PERFORMED: 11/612018 SLOPE TH x READING DATE CLOCK TIME NET TIME WATER LEVEL READING] NETDRO 1 11/6/18 9:05 --- 5.900 2 9:15 10 MIN 9.900 4.00 3 9:15 --- 5.900 --- 9:25 10 MIN 9.300 3.40 9:25 --- 5.900 6 :35 10 IN 9.150 5 9:35 --- 0125 5.900 0 — 6 9:45 10 MIN 9.110 .1 3.21 PERCLATION RATE. 3.1 (min/inch) PERO HOLE DIAMETER 6 inches TEST RUN BETWEEN 4 FT AND 5 FT COMMENTS: Test hole excavated by A+ HOME SERVICES PERFORMED BY: Dan Moran. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. NOTES: PANNONE ENG SVC, LLCDote RECORD DRAWING oF. A�,, 1 /7 /19 DRAWN BY: TH P.O. BOX 100217 ANCHORAGE, AK 99510 q PHONE (907) 272-8218 FAX (907) 272-8211 NTS P.I.D. NO BRATSLAVSKY, LOT 2 en oe 018-322-42 ROMAN & TANYA BRATSLAVSKY p CE 8IZ9 OSP181249 PERMIT NO. 15300 OLD SEWARD HIGHWAY Sheet ANCHORAGE, AK 99516 SOILS LOG 3 OF 3 040.002 Client: Pannone Engineering Services Z__ Project: 15300 Old Seward Highway Date: July 18, 2018 Crowther Associates Particle Size Distribution Table (percent passing sieve size) Sample Source Test pit Sieve Size Pei -cent Puler Percent Finer Percent Finer Percent Finer .3 inch 100 1-1/2 inch 100 3/4 Inch 100 #4 100 #10 99 #40 98 #100 56 4200 37 0.02 inna Classification Silty Sand (SM) 1632Belle),iteCircle I.,4itchoi-cT,c,,?llaslia 99515 Telephone (907) 349-21981 E mail: et owther@alaskadiet 03080038 # .. d.. ION #. HOIHM SNOIIMIS3�1 o #. r # # # # r * Y ■ # # • NO # (INV uAam 3003 s, t ONJMJ0.JOH3NV >� r- ZZOC L Sid ILJ3NOfgi'd `V AWN .4]au0w„y .V W ! l l 1nONV": iO OH d3S m -73rd va Mai 0310N SV 1N3YGSV3-------- 3NII AA3dO�Jd 1N3DVr(]d :]Nn AA3dOM 3� 03080038 # .. d.. ION #. HOIHM SNOIIMIS3�1 o #. r # # # # r * Y ■ # # • NO # (INV uAam 3003 s, t ONJMJ0.JOH3NV >� r- ZZOC L Sid ILJ3NOfgi'd `V AWN .4]au0w„y .V W ! l l .. •tet G..X* • tL • • -MVH I t 114 7NV \ f i t I i t ! f 1 r ( t—t._—_.,._ f � i ! MZ IV]d S3MS3 NVd (1109 \h\ v L iM \ \ \ \ \ 4. \ \ 4 i # i ` J \ J 1N3YGSV3 p .a Jdnun ONV Amami cc - ------- ------_.--- .O. i. d3S � { Jia f-_ '" G'tj41�'. -PL-8-8 3-.va nne—sof UNlmln8 3VgV8J A801S-33Mi s 6 i9 o/ ! \\\ fyVQ-lj!^ I, '4j`bS 22 ['69 LZ -- S LOZ iV]d NC)islltlaons oisAv' sm�98 J--1 h \ \ \ `-LN3YV3SV Ota \ (INV 3NOHd333I ,OZ w LZ — g I,OZ Ivid NC?ISmians USAViSiVd 30 I iol N`C1PA`/rY MUNICIPALITY OF ANCHORAGE 11 On-Site Water&Wastewater Program PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http://www.muni.org/onsite —11161:4Tri Depart mcnt NICPOfl On-Site Wastewater Disposal System Permit Permit Number: OSP181249 Effective Date: 9/18/2018 Work Type: Septic Upgrade Expiration Date: 9/18/2019 Tax Code Number: 01832242000 Site Legal Address: BRATSLAVSKY LT 2 G:3134 Site Mailing Address: 15300 OLD SEWARD HWY, Anchorage Owner: BRATSLAVSKY REVOC TRUST 2018 Lot Size in Sq Ft: 69138 Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: This permit is for the construction of: 90)L 0 Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing c1/25i/S c# 1 : t size Sr-len-7 +Iv Le boom.- f /�Ul /1414 $1 Date:/ JReceived By: ` 1. / q/Iq u s p Issued By: �`�/ � il�r•� �w fie. Date: -f 40-/!$ eiRePtn1111 MUNICIPALITY OF ANCHORAGE Community Development Department r �' Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 018-322-42 Property owner(s) Roman & Tanya Bratslayski Day phone Mailing address 15300 Old Seward Highway, Anchorage, AK 99516 Site address 15300 Old Seward Highway Legal description (Sub'd., Block & Lot) Bratslaysky)Lot 2 Legal description (Township, Range & Section) Lot Size 69,138 Sq. Ft. Number of Bedrooms (r ` CO APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (Z all that apply) Absorption Field U Initial ❑ Single Family (SF) X (w/wo ADU) Septic Tank ❑X Upgrade n Duplex (D) Holding Tank ❑ Renewal ❑ — Multiple Dwellings Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. V)\(7 (Signature of property owner or authorized agent) Permit/Rush Fees: 5(01 Waiver Fees: Date of Payment: Date of Payment: Receipt Number: DpOo1Receipt Number: Permit No. OS P 17 14 1QWaiver No. Permit App_-:- c Munidpality of Anchorage On-site water and Wastewater REVIEWED FOR CODE COMPIJANCE Pannone Engineering Services [lc OSP181249,Deb ftckenfuss,09/18A Steven R. Pannone, Principal Registered Professional Engineer E-mail:steve@panengak.com August 29, 2018 Subject: Bratslaysky, Lot 2 Septic System Install Permit Request Design Narrative This is a design narrative for a permit to install an upgrade septic system to be issued for this property. The proposed systems will serve an existing five bedroom (5) bedroom house. Currently the lot is developed. The existing drain field is in failure and will be abandoned per code. This lot and the surrounding lots are served by private wells. Required separation distances to wells will be maintained. 1. Soils. One test hole was performed on this lot by PES in July of 2018, and groundwater was monitored for at least seven days. Ground water was not observed to a depth of 18' below the surface in the test hole monitor tube after the 7 day monitoring period. Bedrock was not encountered in the test hole. Based on the results of the percolation tests and overall soils appearance; an application rate of 1.2 gallons/day/square feet was used for a conventional wastewater system in the area of the test hole. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The existing topography generally slopes from the north to the south in the area surrounding the septic system at approximately 5%-7%. There is a slope to the west that will be avoided. There are no steep slopes within 50' of the proposed drain field. The proposed drain field will maintain 50' separation all steep slopes. 5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On-Site Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 t • WELL (E) % 1 /.) *': ! i 1 f I \ �'1'.. 3 / , ' • 1 i \ ' \ / , 4�j: ) 1 f , 1 \� Xis ` ` I I \y"-'/.t ) f r cJ� / 2 ��, J ,/ o / . . , , i '1 ryl 1 , . ,t 2 , . .. -- • • i --- - DRIVEWAY ,, r 15008 CONCRETE SEPTIC TANK (E) 1 // ' i� ----- DECOMMISSION �W DECOMMISSION PER CODE AND ; ; / INSTALL 2000g SEPTIC TANK (P) ' . 6- INSTALL DCO ' O� \ • i i DRAIN FIELD(E) ;' 1r. DECOMMISSION PER CODE 6BR HOUSE \ / 'oh t TH-1 ^T I _� - SS CC . .. 4 \ / ! ;' 33' ROADWAY AND • / / / , UPGRADE DRAIN FIELD(P) UTILITY EASEMENT � ' / / / 5OLF x 2.5'W x 8.0'ED x 12.0'TD 33i•'...-...f.___„..--' 3Q /� / ! : / / INSTALL CO AND MT AT EACH END (v I ' / / / ` / REMOVE AND REPLACE FOR RESERVE r f�.--It-•' rf---'!---- • O I I• • 0� i ' !/ /' SEPTIC AREA(E) ! • ! ; , • I DESIGN PARAMETERS ABBREVIATIONS UPGRADE SEPTIC SYSTEM TH TEST HOLE NO. BEDROOM: 6(900 gpd) TANK SIZE: 2000g (P) PROPOSED PERC RATE: 3.2 MPI (E) EXISTING SOIL RATING: 1.2 GPD/SF CO CLEAN OUT NO. AREA RQD: 750 SF MT MONITOR TUBE NO. SYS. TYPE: DEEP TRENCH 8.0' ED TYP TYPICAL MIN LENGTH: 46.9 LF USE: W WATER LINE/ 5OLFx2.5'Wx8.0' E.D., 12' TD WELL RADIUS TOTAL AREA: 800 SF SS NEW SEPTIC NOTES: •`��.�\\ Dote CHANGE ORDER PANNONE ENG SVC, LLC ��� P.O. BOX 100217 ANCHORAGE, AK 99510 ,c�OF AC, 0S1,k 9/25/2018 �74P' .I Scole PHONE (907) 272-8218 FAX (907) 272-8211 /�. �.� ':9 v 1"=50' DRAWN BY: %*C 4•9 __ Pk/OW,* DRM /•' '. ' '• t "NIP ' P.I.D. NO — BRATSLAVSKY, LOT 2 �2 . .�•. ,,R. . , 018 32-2 42 ROMAN & TANYA BRATSLAVSKY d S'teven R. Ponnorae PERMIT NO. 15300 OLD SEWARD HIGHWAY l4r4,, CE 8149 . •4,:„;; OSP181249 PLAN ANCHORAGE, AK 99516 fl,`\\Q�`\O-C- Sheet 3 \\� Munidpality of Anchorage On-site water and wastewater TEST HOLE 1 SOILS LOG - PERCOLATION TEST REVIEWED FOR CODE COMPLIANCE OR ORGANICS SLOPE ` /1'1 ��� / PLAN OSPI81'4• ►` us.09/W W (p 4 /3 // / // / •100 SMI BROWN SAND V // // 5 GM AND GRAVEL 7 // WITH FINES 6 X �Z 4 ( / TH � '\ TH-1 7 �h / Q X ) /1 0) 0) 8 — - \ -,-,-- / / 33' ROADWAY AND 9 I UTILITY EASEMENT 10 11 SMI GRAY SAND ' GM AND GRAVEL I 1 l I 12 WITH FINES \ / 1 t 13 WAS GROUND WATER SLOPE 14 ENCOUNTERED? N 15 IF YES,AT WHAT TH 16 SW CLEAN SAND DEPTH? -DRY X 17 DEPTH TO WATER AFTER MONITORING? -DRY 18 DATE: 7/30/2018 BOH CLOCK WATER READING DATE TIME NET TIME LEVEL NET DROP READING 1 7/16/18 10:00 --- 3.34 -- 2 10:10 10 MIN 7.50 4.16 DATE PERFORMED:7/16/2018 3 10:10 --- 3.34 -- 4 10:20 10 MIN 6.81 3.47 5 10:20 --- 3.34 -- 6 10:30 10 MIN 6.54 3.20 5 10:30 --- 3.34 -- 6 10:40 10 MIN 6.51 3.17 PEROLATION RATE 3.2(min/inch)PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 4 FT AND 5 FT COMMENTS:Test hole excavated by A+HOME SERVICES PERFORMED BY: Dan Moran. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. NOTES: PANNONE ENG SVC, LLC �4 OF/���l Dote FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 -4 .••••'•...ts, i 8/9/2018 PHONE (907) 272-8218 FAX (907) 272-8211 .4 g'`P ,...4.,...1.--7 Scole DRAWN BY: %*: 4,9•t-1 1 * / / DRM • ••••• o P.I.D. NO BRATSLAVSKY, LOT 2 / .4�\ / 018-322-42 ROMAN & TANYA BRATSLAVSKY St'e'ven R. Panriorie PERMIT NO. ll ;2'�•. CE 8149 •c• oe OSP181249 15300 OLD SEWARD HIGHWAY i) sf .\fir SOILS LOG ANCHORAGE, AK 99516 1l,l\\\\�```� � Sheet 3 Municipality of Anchorage Q l�Wut, j Wu.4 r REVIEWED FOR CODE CANCE OSP181249,Deb lhfxkenfuss,09/18/' SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55. 2. SCOPE OF WORK: VERIFY SEPTIC TANK, INSTALL SOIL ABSORPTION SYSTEM. 3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 18 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 18 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. 4. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK. 5. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED. 6. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES. 7. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE ENGINEER. 8. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN. 9. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED—LINE AS—BUILT DRAWINGS TO THE ENGINEER. THE RED—LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND TANK ELEVATIONS. 10. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN—OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING. 11. THE CONTRACTOR PROVIDED DATA (UPON WHICH THIS RECORD DRAWING IS BASED) APPEARS TO REPRESENT THE PROJECT AS CONSTRUCTED. THIS DATA IN CONJUNCTION WITH THE PERIODIC FIELD OBSERVATIONS BY THE ENGINEER (OR HIS DESIGNEE) AS REQUIRED BY AMC 15.65 DOES NOT GUARANTEE THAT THERE ARE NO HIDDEN DEFECTS BY THE CONTRACTOR. 12. THE CONTRACTOR SHALL SIGN THE FOLLOWING: I CERTIFY THAT ALL WORK WAS PERFORMED IN ACCORDANCE WITH THE APPEND PERMIT, AND ANY AND ALL CHANGE ORDERS, AND THAT THE AS—BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED. CONTRACTOR: BY: . TITLE: DATE: NOTES: PANNONE ENG SVC, LLC -``OF At, Dote CONSTRUCTION :(16,,k1 P.O. BOX 100217 ANCHORAGE, AK 99510 r�� 2018 PHONE (907) 272-8218 FAX (907) 272-8211 /�aj�P `ti••1y+r Scale DRAS WN BY : •••X14*/� .. .1k•,�� P.LD.NTNO BRATSLAVSKY, LOT 2 018-322-42 ROMAN & TANYA BRATSLAVSKY r Steven R. Pannopefrer PERMIT NO. •15300 OLD SEWARD HIGHWAY /0 •. CE •8149 `e OSP181249 PLAN ANCHORAGE, AK 99516 +ilr`\�• OFESSlO`� � Sheet 3 \\\N�� `\ N `\ \ `\ N `\ N \\ \ • i • • a 0�� NOTES �o� S7, \ ' 1. RECORD DATA SHOWN HEREON IS PER PLAT 2015-27, �p^^ 20' TELEPHONE AND ANCHORAGE RECORDING DISTRICT. AD ELECTRIC EASEMENT SAF . . \`\ _22 Ia 2. THIS DRAWING IS BASED ON A FIELD SURVEY PERFORMED `\\ 22, BY EDGE SURVEY AND DESIGN, LLC ON 8/21/2018. 70• / \ \\ �� 3. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE n- \ THE EXISTENCE OF EASEMENTS, COVENANTS, OR o \\ RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED N LOT 1 • P '9� SUBDIVISION. THIS AS-BUILT SURVEY SHOULD NOT BE BRATSLAVSKY SUBDIVISION ��. USED FOR CONSTRUCTION OR BOUNDARY LOCATIONS. ci PLAT 2015 — 27 \`\\ ��� 50' 25' 0' 50' 00 Lq evP 1„ = 50' " 6i 1`� ,, \ F9S1B \ , \ a), F 84.0' `\ / \ 0 'L `\ �' \ 1.1 11' c FA `5 i/ s' ,,'` oc5 \ LEGEND LOT 2 `'F,'04, `s�;� �•°? -\\ \\ BRATSLAVSKY SUBDIVISION -Ks, ‹<, -9,�, / C)°` /^\ \ PROPERTY LINE .3 Co PLAT 2015 — 27 Fti .' / \ n' °' 69,138 Sq.Ft. , / �/' `\\ \\ - - - - - ADJACENT PROPERTY LINE Q C•1 // `\\ N - - EASEMENT AS NOTED co i. THREE-STORY FRAME BUILDING ,�� \`\ BUILDING AS-BUILT DATE 8-8-14 / `\ To in /' OW WELL m o / \ / LOT 1 A \\`\ • SEPTIC CLEANOUT 3 Z /� 28.3, i GOLD PAN ESTATES \`\ 0 /e I PLAT 2011 - 111 \ rn / oma N' - co / rn i i 362, i co L 37.8' 6?s• SURVEYOR CERTIFICATE A SEPTIC CLEANOU TS 46.2' 1 _b , I HEREBY CERTIFY THAT I HAVE PERFORMED AN ���\\\\� Q • 1 _ I AS-BUILT SURVEY ON THE PROPERTY SHOWN �~ of A it E D G E 33' ROADWAY ;�, I >, HEREON AND THE IMPROVEMENTS EXIST AS i�P • •:1&_1i, SIIIVEY ANN RESIGN, LLC Co AND UTILITY 4 SHOWN. FIELD SURVEY: 8/21/2018 /O> • `'i •9 �j 12501 OLD SLWAKU, U ANCt10RAGE, AK 995 15 N Phone (907) 344-5990 Fax(907) 344 7794 EASEMENT ``� *••�Tlfi I\ ••* AS—BUILT SURVEY Co'0 _ I , _J S89'58'51"W 182.46' ?Ze.i-- ... ... .... / LOT 1 BRATSLAVSKY SUBDMSION co � PLAT 2015-27 ANCHORAGE RECORDING DISTRICT N 6 .. Mark A.Aimonetti •: 9/1 7/18 1'.. •... No. 13022-S .•.�,� DRAWN BY: DATE: MOA GRID: -o LOT 232illi 1 ``9 •.9117/18 .•,:.. -^. MARK A. AIMONETTI 1kk OFESSI0NN.`��.� MA 9/17/2018 •SW 3134 a PLS 13022 �X\\�>>� CHECKED BY: SCALE: SHEET: j •TD 1"=50' 1 OF 1 a ~[:LE,~.TER ANCHORAGE AREA. BOROUGH '~ · ~ .... '~' G~TER ANCHORAGE AREA BORO~-~qH Dep~ment o~ ~nwronm~n al Q ~.. ~y 3500 Tudor Road -- Pouch 5-050 ' An~eraqe, B.].s~ 99502 987 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: MAILING ~ ~ ~'~'~ =, - ) ADDRESS ~'~'L'~' ////~.Lb/~.~)~)xC '///~'.7~ PHONE?~r-~./-~ LEGAL DESCRIPTION DISTANCE FROM WELl /"~ LIQUID CAPACITY (/°)"0 ~F.~;' b ') MATERIAL L~'~o/L'~'~ ~ 7~ GALLONS. INSIDE LENGTH NUMBER OF COMPARTMENTS '(?'~J ~-~ LIQUID INSIDE WIDTH DEPTH SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS / OUTSIDE DIAMETER LINING MATERIA~ ("~/~('-/,~'- ~'(~- ~ i~/Ai~J'.~ , NEAREST LOT LINE ,~(~ / 7~ ~/' TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) OR WIDTH / , LENGTH ~/ , DEPTH DISTANCE FROM WELL /~ .~f.~?~,'JBUILDING FOUNDATION SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL .~.~cO0-NDATIO]~ . NEAREST LOT LINE NUMBER OF LINES ///~DISTANCE BETWEEN LINES~ ~ ABSORPTiON/A~EA/- SQ. FT. LENGTH OF EACH L~x~E~ TOTAL LENGTH , OF LINES .~IN. TOTAL EFFECTIVE DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE-- WELL: ~E~ 0 ~? 6~q ~SL 60c/? ~/ DISTANCE FROM TYPE , DEPTH _, BUILDING FOUNDATION NEAREST C/ SEPTIC ~/ SEEPAGE LOT LINE ~, SEWER LINE , TANK. ., SYSTEM ~ .... WATER ~'~ SAMPLE__, NEAREST /- OTHER ~' ,CESSPOO[ c_ , SOURCES __ DISTANCES: DATE DIAGRAM OF SYSTEM APPROVED (-~. - "' ~ ~EAL1H A~JIHORIT¥ GrEA*'ER ANCHORAGE AREA BOROUGH SEWAGE DISPOSAL SYSTEM m APPLICATION AND PERMIT PERMIT NO. COMPLETION DATE ANTICIPATED , DRAIN FIELD NOTE~ THIS FERMIT lB NOT VALID WITHOUT BOIL. TEB'I' FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO pROSECUTION. MINIMUM DISTANCES, REQUIREMENTB FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE Pit SEPTIC TANK TO SEEPAGE PIT WALL · DRAIN FIELD SEPTIC TANK SEEPAGE PIT ' , DRAIN FIELD TO NEAREST LOT LINE, WELL TO SEPT[C TANK ~} SEEPAGE PIT /~/~/~ DRAIN FIELD ALSO CONSIDER AREA WELLS. ,' WATER MAIN TO SEPTIC TANK ., SEEPAGE PIT DRAIN FIELD S EPT,C TANK. -. SErRAtE P,T TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTLC TANK AND INTO CRIB CROSSING GAP OF DIAGRAM OF SYSTEM GRAVEL BACKFILL CONFORm TO BOROUGH REGULATIONS REGARDING INSTALLATION. HEALTH AUTHORITY OR LICENSED DESIGNER I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUgh ORDINANCE NO. 28-68 AND THAT THE ABOVE Soil Log performed for: Mr. Joe Scheffield 705 Muldoon Rd. # 168 Anchorage, Ak. 99504 Soil Characteristics 1-.c 6~~ Well sorted sand & gravel 7'l clay 8J 9'~ well sorted Sand & gravel icj at; Lot 210 Section 33 To~.mship 12N~ 3W SM (corner Old Seward ~y & Rabbit Creek Road) no ground v~ater was encountered. 170 ft2/ bedroom 4 bedroom house general slope of land is to the northwest. test performed by Karen S. E~et on : March 31, 1972 GREACER ANCHORAGE AREA BOROUGH SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT PERMIT NO, LEGAL DESCRIPTION INSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH COMPLETION DATE ANTICIPATED . OTHER NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION, sEPtiC TA"K ~'~E /~'5'-~'; ('/~Z ~ ,q ~.~J~,~ d~,.~r~z~:~.~ ..~ ~,~ .~/,~- %0//{~d/- / MINIMUM DISTANCES, REOUIREMENT~ FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT ~'~-J~' DRAIN FIELD SEPTIC TANK TO SEEPAGE PiT WALL t SEPTIC TANK ~-~-' TO NEAREST LOT LINE. WELL TO SEPTIC TANK , DRAIN FIELD · J¢o _. SEEPAGE PIT . _~.ALSO CONSIDER AREA WELLS. -. SEEPAGE PIT /0 WATER MAIN TO SEPTIC TANK DRAIN FIELD SEPTIC TANK. . SEEPAGE PIT , DRAIN FIELD TO RIVER. LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK A~ND INTO CRiB CROSSING GAP OF " HEALTH AUTHOoR -I~/~TY LICENSED DESIGNER I CERTI fY THAT I Am FAMILIAR WITH ThE REQLII,E~IENTS OF GREATER ANCHORAGE AREA BO,~GH~?' NANCE NO. DESCRIBED SYSTEM IS IN AOCORDANCEWITH SAID CODe. X - /* // // 28-68 AND THAT THE ABOVE MUNMPALITY OF ANCHOR -AGE � Development Services Department �� r,� Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval 018-322-42-000 Parcel I.D. rf Imo. Expiration Date: 13 Z �Q �- 1. GENERAL INFORMATION Complete legal description Bratslaysky L2 Location (site address) 15300 Old Seward Highway Current property owner(s) Roman Bratslaysky Day phone Mailing address Real estate agent Day phone 2. TYPE OF DWELLING: F-71 Single Family (w/wo ADU) ❑ Duplex' ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 5 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well FLI Private Septic R Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. Date of Payment A a/Zo Receipt Number 07SUE, Date: Date of Payment Receipt Number COSA # _0_--,G2-0151 f Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA -COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Reliance on this report by another person is at their own risk. Pannone Engineering Services LLC highly recommends buyers hire their own engineer to evaluate this report. Name of Firm Pannone Engineering Services Phone (907) 745-8200 Address P.O. Box 1807 Palmer, AK 99645 Engineer's Printed Name Steven R. Pannone P.E. Date'f"7" OF Aqs��� a 6. DSD SIGNATURE •'• V, System #1 Approved for .� bedrooms A Ste n R. panI—, e Fc . CE 8149 System #2 Approved for bedrooms. r •, o�� Disapproved �D Conditional approval for bedrooms, with the following stipulations: WAI LK ANU r PROGK O N By: Original Certificate Date: 22 Zd The Municipality of Anchors a Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet COSA AILED Checklist r-/ -I Legal Description: Bratslaysky L2 Parcel ID: 018-322-42-000 If more than 1 septic system on lot: COSA Checklist # 1 of 1 A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 1972 Total depti ft Cased to 12 ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) 18+ in. Date of flow test for COSA 9/15/20 Static water level at beginning of test 48.4 ft. Comments � ICO,,J- -�, B. TANK DATA Age of tank(s) 11 11 3!2618 years Tank type/material steel Measured operating fluid level in septic tank new ❑ Standpipes/foundation cleanout per record drawing Date of pumping 9/18/20 D. ABSORPTION FIELD DATA 11/13/2018 Which system tested (date installed) na ❑ ALL standpipes present per record drawing Total measured depth from grade 17 ft (max) Measured depth to pipe invert from grade 9 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective Structure served by this system 1 Well production at time of test 4.3 gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑✓ No ] Coliform bacteria is Negative Nitrate mg/L 9 Nitrate less than MRL (ND) Arsenic x.147 ug/L ❑ Arsenic less than MRL (ND) Collected by Pannone Engineering Date of Sample 9/2/20 R Em - C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date na Results [Z]Pass For 05 bedrooms Fluid depth prior to test in Water added gal New depth in Elapsed time min ❑ Code -required soil cover over field Final fluid depth in ❑ System presoaked Absorption rate gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) _ date of test) Gallons introduced gallons If yes, enter date Comments/Deficiencies: new System 11/2018 COSA Checklist yellow sheet E. .SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' 0 Yes Community Sewer Manhole/Cleanout > 100' Q Yes if No ft M Yes if No Neighboring Tank > 100' Yes if No ft Private Sewer/Septic Line > 25'✓M Yes if No Absorption Field on Lot > 100' Yes if No ft Holding Tank > 100' ❑✓ Yes if No Neighboring Absorption Fields > 100' Yes if No. Water Main > 10' Animal Containment > 50' ® Yes if No F71 Yes if No ft 0 Yes if No. Water Service Line > 10' Yes if No Manure/Animal Excreta Storage > 100' If septic tank is under driveway Community Sewer Main > 75' M Yes if No ft [Z] Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water > 100' Yes if No. Property Line > 5' 0 Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' if No Yes if No ft Private Wells > 100'✓0 Yes if No. Water Main > 10' Q Yes if No ft Community Wells > 200' 0 Yes if No. Water Service Line > 10' Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Yes if No ft If absorption field is under driveway comment below Property Line > 10' 0✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10' Yes if No ft Private Wells > 100' U✓ Yes if No Water Service Line > 10' Yes if No ft Community Wells > 200' Q✓ Yes if No Surface Water > 100' F/I Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION l certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet ft ft ft ft ft ft ft ft ft ft MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING GENERAL INFORMATION Complete legal description Location (site address or directions) Property owner Mailing address ~?..~_.~ '"~-C~C.. Dayphone S¢5-- 57e~ Lending agency Mailing address Agent Address Day phone Day phone Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: - lng to the legality and status of system: TYPE OF WASTEWATER DISPOSAL: Individual on-site / NOTE: If community well system, provide written confirmation from State ADEC attest- Holding tank Community on-site Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1191) Front MOA 5. STA'r'EMENT OF INSPECTION BY ENGINEER As 6ertifie8 by rdy ~eal affix(~d he~-et0 and aS 0~ th~ validation date shown bej°w, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, funotional and adequate for the number of bedrooms and type of structure indicated herein. I fur[her verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. NameofFirm /;bb.~ ~?~..,,r~,~.~.~o~ '~. ~_ Phone ~¢- %~ 1~ Address ~0~ ¢ I~ ¢ ~O~ o Engineeds signature DHHS SIGNATURE ,'~'. Approved for 4 bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments Date The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and thei r lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ~UNICIPALIIY OF ANCHORAGE ENVIRON~EN[AL SERVICES DIVISION Municipality of Anchorage SEP 2 0 1996 DEPARTMENT OF HEALTH & HUMAN SERVICE~ E C E Environmental Services Division J V E D 825 L Street, RoomS02 · Anchorage, Alaska 99501 · (907) :34:3-4744 Legal Description: LoT A. WELL DATA Health Authority Approval Checklist ~-~C- ~' ~: T' I ~[,I,~ ! Parcel I.D.: Well type Log present (Y/N) ~ Total depth ? ~/1~ Sanitary seal (Y/N) y If A, B, or C, attach ADEC letter. ADEC water system number Date completed Cased to ~ .~ Casing height (above ground) Wires properly protected (Y/N) Y Date of test Static Water level Well production FROM WELL LOG AT iNSPECTION g.p.m. ~' g.p.m. WATER SAMPLE RESULTS: Coliform ¢ Nitrate ~.j~ Other bacteria ~ 5 / Date of sample: c//lol c/~ Collected by: SEPTIC/HOLDING TANK DATA Date installed //-/~-' 7 ~ Tank size /~'oc) Number of Compartments / Cleanouts (Y/N)_~ Foundation cleanout (Y/N) y Depression (Y/N) ~ High water alarm (Y/N) ' ~ Date of Pumping ~ b~ ~ Pumper / ABsoRpTIoN FIELD DATA gate installed lTJ'/O-7/-~- Soilrating ~o~ft%'bdrm) Length' <;)--/ Width J ~, Gravel thickness below pipe Effective absorption area Date of adequacy test Fluid depth in absorption field before test (in.); Fluid depth ~ ~ (ins) Minutes later:. ~' ~) Monitoring Tube present (Y/N)__/~_ Depression over field (Y/N) __ <?/lo/~ ~, Results(Pass/Fail) '~' For Y ~) Immediately after ~,~D gal. water added (in.): Peroxide treatment (past 12 months) (Y/N) System b~pe ~ Total depth ! ~" Absorption rate = .~ ~O'¢~ g.p,d. J'~ If yes, give date bedrooms 72-026 (Rev. 3/96)* D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at* "Pump off" level at* High water alerm level at* *Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot Absorption field on lot Public sewer main Sewer/septic service line On adjacent lots On adjacent lots '.~ Public sewer manhole/cleanout ~'~/~r,~ ~-~ Lift station ~/ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: ~'Y'¢,'¥~ ,% ~ Foundation _ c~ I /::::~ . Property line .~ I~ ~-'~ Absorption field /n/ Water main/service line .~ ,'~O ~: Surface water/drainage '/%l¢ ~4~- Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO: Property line '~ I 0 ~"~'~ Building foundation '~, ~ r~ ~-~. Water main/service line Surface water [~,~. o V~J2 Driveway, parking/vehicle storage area ~ Curtain drain ~'~ 0,¢. &_ Wells on adjacent lots I 0 ;~ ~' ENGINEER'S CERTIFICATION . /' I certify that I have determined thru field inspections and rewew of Mumc~pal records'th~'t~e ~bO~/~ sycCtCrn9 are in conformance with MOA HAA guidelines in effect on this date. , Signatur: -- '~-'~ .~ ~'~?~, ,4 Engineer s Name ~-~ ~ ~.~ HAA Fee $ Receipt Number 72-026 (Rev. 3/96)* Waiver Fee $ Date of Payment Receipt Number