Loading...
HomeMy WebLinkAboutT12N R3W SEC 33 LT 250 /~" MUNICIPALITY OF ANCHORAGE ~ DEPART[VIENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE '7~~ [~NEW DISTANCE '0: IWe], /~ I os Dwelling ~P <Z Manufacturer ~ ~fl ~ateria]o~ff~)~ No. of compa~ents ~ Top of t[~to finish graOe ~' ~*~ j~'~ ~' inches ,1~' OTHER ~-~ ~/~~ ., REMARKS ' , 72-013 (Rev, 3/78) MUNICIPALITY OF ANCHORAGE Department/A~ Health and Environmenta~protection 825 Street, ~_nchorage, AK. 3501 ,. 264-4720 * * * HANDWRITTEN PERMIT * * * Bermit W~-~-R 0N-SITE SEWER PERMIT ~pplicant: ~u3{o~q ~C Mailing Address: ~ocation: Phone Number: Legal Description: '~1~63 ~tx9 ~ac. B ~ ~o~ 2CO Lot Size: '~ Type of Soil Absorption System Is: Trench: Drainfield: Seepage BeC: ~ Holding Tank: Maximum Number of Bedrooms: ~/ Soil Rating(sq.ft/br) /~ The Required Size of the Soil A~sorption System Is: ' /.// / / DEPTH LENGTH q~ m~ GRAVEL DEPTH , $~ WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE = /a$-O GALLONS * * P~rmit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number o'f residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet f~r a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a conLmunity sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER ~1~ 1 9 8 3 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells set forth by the Municipality of Anchorage. (2) .(3) Signed: as I will install the system in accordance with codes. I understand that the on-site sewer system may require enlargement if the residence is remodeled to inc'lude more that 3 bedrooms. ~ ~/ Issued by: ~. ~/~'J~.~'~ Applican~ ,"Z/~,//3 ~// Date: PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O SOILS LOG "' MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION p PERCOLATION TEST 825 L. Street, Anc~norage, Alaska 99§0~ 264-4720 SOILS LOG - PERCOLATION TEST SLOPE WASGROUNDWATER ENCOUNTERED? IF YES, AT WHAT DEPTH? SITE PLAN Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE (minutes/inch) PERFORMED BY: /J. X/:~ CERTIFIED BY: ALASKA etlUI[NOFImffITAL COIIT[NOL SEIqdlCES, ~n§lneerinq 6 ~nuironmenl~l Studies InC. Supplemental Soils informaLion. Subdivision ~/Z~J ~ ~ ~y~ Blook Z~/-' 2~-0 LOT TH 1 2 :3 4 § 6 7 6- 10- 11 13 14 15 16 17 18 19 20 11 13- 14- 15- 16- 17- 18- 19 2O LOT lH 1 2 3 4 5- 6- 7 8 9- 10- 11 12 13 14 15 16 17 18 19 20, LOT TH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1200 U.Jesl 33rd Auenue. Suite J~ · Anchoraqe, Alaska 99503 · [907) 276-1361 ALASKA eliLIIROFlm FITAL COI TROL S F UIC S, IRC. ~nqin~rinq 6 ~.uironmenlal $1udi~s SPECIFICATIONS FOR SEEPAGE BED ALTERNATIVE WASTEWATER TREATMENT SYSTEM- T12N R3W SECTION 33 1.0 GENERAL 1.1 THE DRAWINGS SHALL BE A PART OF THIS SPECIFICATION. 1.2 ALL MATERIALS AND WORKMANSHIP SHALL MEET THE REQUIREMENTS OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERMIT. 1.3 IT IS THE RESPONSIBILITY OF THE OWNER TO OBTAIN ALL NECESSARY PERMITS OR EASEMENTS. 2.0 LIFT STATION (NOT USED). 3.0 SEEPAGE BED 3.1 THE GRAVEL FOR THE BED SHALL BE SIZED BETWEEN 0.5 TO 2.5 INCH AND RELATIVELY FREE FROM SILT OR SAND. 3.2 THE BOTTOM OF THE EXCAVATION SHALL BE RAKED WITH THE BACKHOE BLADE TO INSURE THAT THE BOTTOM HAS NOT BEEN COMPACTED DURING EXCAVATION. THE BOTTOM ELEVATION SHALL BE PLUS OR MINUS 2". 3.3 THE DISTRIBUTION PIPE SHALL BE 4 INCH RIGID PVC OR POLYETHYLENE. THE PIPES SHALL BE LAID LEVEL. 3.4 AN OBSERVATION PIPE SHALL BE PLACED AS SHOWN IN THE DRAWINGS. IT SHALL BE RIGID PVC, ASTM 3033 D-3034. THE SECTION SHOWN WITH HOLES MAY BE EITHER DRILLED 0.5" HOLES @ 6 INCH CENTERS ON OPPOSITE SIDES OF THE PIPE OR A REGULAR SECTION OF REGULAR PERFORATED DISTRIBUTION PIPE MAY BE CLAMPED TO THE SOLID SECTION WITH A NO HUB COUPLING OR SOLVENT JOINT. A RUBBER RAIN- CAP (JIMCAP OR EQUAL) SHALL BE PLACED ON THE TOP THE PIPE. 3.5 THE GRAVEL SHALL BE COVERED WITH A LAYER OF UNTREATED BUILDING PAPER OR A NONWOVEN FABRIC SUCH AS MIRAFAR FIBRETEX 200 GRADE, OR POLY-FILTER X OR EQUAL. 3.6 IF INSULATION IS REQUIRED THE INSULATION SHALL BE DOW EXTRUDED BLUE STYROFOAM BOARD OR ARCO GEOFOAM EMBANKMENT INSULATION BOARD OF THE THICKNESS SHOWN ON THE DRAWINGS. 3.7 THE TOP OF THE BED SHOULD BE PLANTED WITH A WHITE CLOVER AND RED FESCUE MIX. ALASKA ENVIRONMENTAL CONTROL SERVICt~-"INC. 1200 West 33rd Avenue Suite B ANCHORAGE. ALASKA 99503 Phone 276-1361 JOB ALASKA ENVIRONMENTAL CONTROL SERVICC-~', INC. 1200 West 33rd Avenue Suite B ANCHORAGE. ALASKA 99503 Phone 2764.361 SHEETNO. OF ~' DATE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF iNSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) L~:,T' ,:~,.¢.,_,,. :: ,~_~w-~ :-~ ':l,<~!'/ ,,~:':~.~ :, ~-~-" Location (address or directions) (b) Applicant Name4q~ ~/~.,;~ Telephone: Home Business Applicant Address (c) Applicant is (check one): Lending Institution []; Owner/buildert[~; Buyer []; Other [] (explain); (d) Lending Institution Address (e) Real Estate Company and Agent Address (f) Telephone Telephone , Mail the HAA to the following address: TYPE OF RESIDENCE Single-Family~ M u It i~h/~[] Number of Bedrooms ~ ~"~- ~ Ot~er 3. WATER SUPPLY . Individual Well.~ Community [] Public [] Note: If community well system, must have written co, nfirmation f, rom the State Department of Environmental Conservation attesting to the legality and status. ~,, \ ~ 4. SEWAGE DISPOSAL , i i , Onsite~' Public [] Community [] Holding Tanb[] Note:/' ~lf community well system, must have written confirmation from th~ State Department of Environmental Conservation attesting to the legality and status. ' ' 72-025 ($1/84) Page 1 of 2 5. ENGINEERING FIRM PROVIDINg., INSPECTIONS, TESTS, FILE SEARCH, DA~ AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Address Date Telephone Seal DHEP APPROVA~.~ bedrooms bY~ Terms of Conditional Approval "\ ' CAUTION The Muncipality of Anchorage Department of Health anu Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representation~given in paragraph ~ above by an independent professional engineer registered in the State of Alaska. The DHEP does,this as a courtesy to purchasers of homes and their lending r~stitutions in :)rder to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (i 1/84) CONSULTING ENGINEER TELEPHONE: (907) 279-3916 RESIDENTIAL WELL INSPECTION LEGAL: LOT 250, SEC. 33, T12N, R3W LOCATION: 1.2 MILE RABBIT~ CREEK ROAD OWNER: GENE JACKSON TYPE OF WELL: SINGLE FAMILY WELL LOG AVAILABLE: NO INSTALLATION REQUIREMENTS MET: YES PUMP YIELD: 8-9 GALLONS PER MINUTE DATE OF INSPECTION: OCTOBER 13, 1986 TEST PROCEDURE: WELL WAS PUMPED AT A CONSTANT RATE OF 8 GALLONS PER MINUTE WHILE THE DRAWDOWN WAS MONITORED WITH AN ACOUSTIC PROBE. THE WELL WAS PUMPED TILL THE DRAWDOWN STABILIZED. STATIC WATER LEVEL WAS FOUND AT 99 FEET BELOW TOP OF. CASING. AFTER 30 MINUTES OF PUMING THE WATER LEVEL STABILIZED AT 107. THE WELL WAS PUMPED FOR AN ADDITIONAL 30 MINUTES WITHOUT ANY DROP~ IN WATER LEVEL. THE WELL RECOVERED 100 % IN 12 MINUTES. TEST FOR COLIFORMS: WATER WAS TESTED FOR COLIFORM BACTERIA ON OCTOBER 14, 1986. TEST WAS NEGATIVE. TEST RESULT: THIS WELL MEETS THE REQUIREMENTS OF THE MUNICIPALITY OF ANCHORAGE. The Municipal requirement for well flow is 150 gallons of water per bedroom per 24 hours.This well surpasses this requirement. The assessment of the condition of this well applies only to the conditions as of this date. The flow rate of the well may change due to subsurface conditions that may not be observed from the surface, and changes in land use and other factors that may impact the conditions of the aquifer feeding the well. I~ i~.r~[~ ~203 w. 15th AVE "C" SUITE 203 ~ ~ ~ ANCHORAGE, ALASKA 99501 · CONSULTING ENGINEER TELEPHONE: (907) 279-3916 SEPTIC SYSTEM ADEQUACY TEST LEGAL: LOCATION: OWNER: RESIDENCE: WELL: SEPTIC SYSTEM: LOT 250, SEC. 33, T12N, R3W 1.2 MILE RABBIT CREEK ROAD~"~J.'' ~' ?-,~ GENE JACKSON ~...~.~ PRIVATE, ON SITE FROM MUNICIPAL RECORDS: TANK: GREER STEEL, TWO COMP. 1250 GAL. ABSORPTION SYSTEM: BED ABSORPTION AREA: 756 SQ. FT. SOIL RATING: 125 INSTALLATION DATE: JULY 1983 DATE OF PUMPING: OCTOBER 16, 1986 DATE OF TEST: OCTOBER 13, 1986 TEST PROCEDURE: SYSTEM WAS INSPECTED AND MEASURED. TANK WAS FOUND WITH 2.5 FEET OF COVER AND WITH 46 INCHES OF LIQUID. CLEAN OUT BETWEEN TANK AND BED WAS 3 FEET DEEP AND DRY. MONITORING TUBE IN BED WAS 51 INCHES DEEP AND WITH ONE INCH OF SLUDGE. 450 GALLONS OF CLEAN WATER WAS ADDED TO THE CLEANOUT WHILE THE WATERLEVELS WERE MONITORED. TANK LEVEL REMAINED CONSTANT, WHILE THE LEVEL IN THE MONITORING TUBE ROSE TO 4.75 INCHES. 90 MINUTES AFTER ADDING THE WATER THE LEVEL IN THE MONITORING TUBE WAS 1.5 INCHES. THE SOIL HAD ABSORBED THE WATER. TEST RESULT: THIS SYSTEM MEETS THE CODE REQUIREMENTS OF THE MUNICIPALITY OF ANCHORAGE. The operational life of all septic systems depends on the local soil conditions, groundwater levels that may fluctuate during the year, and the water usage of the family bein9 served by the system. These conditions are outside the control of the evaluator of this septic system. We can therefore not give any estimate of how long the system will continue to meet the operational requi- rements of the Municipality and State. A. WELL DATA MUNICIPALITY OF ANCHORAGE (MOA) *r,;~r'TH AUTHORITY APPROVAL (HAA) i~uNICiPALtTY 0~: A EPT Of: HE^LIH b D · . .,,,-,TECTK~,~HECKLIST - FEBRUARY 1984 ENviROH~NTAL ~'~'~ 264-4720 RECEWE. '" ....... ' ...... "' Well Classification Well Log Present (Y/N) Total Depth //O Static Water Level Casing Height Above Ground Electrical Wiring in Conduit (Y/N) Separation Distances from Well: To Septic/Holding Tank on Lot Date Corn pletel~ A' Bj;,~D.' E'~ved (Y/N)Yiel//'~(~ '{~ [ t4~/ Depth of Grouting I~ 0 ~ J"~ Pump Set At I O'7 '1" Sanitary Seal on Casing (Y/N) Depression Around Wellhead (Y/N) ,'~ To Nearest Edge of Absorption Field on Lot ~_.,~C7r7b To Nearest Public Sewer Line Cleanout/Manhole Water Sample Collected by Water Sample Test Results Comments ; On Adjoining Lots ./0~ ; On Adjoining Lots .~'t~~) ./~/A/~/. To Nearest Public Sewer .,~///~ To Nearest Sewer Service Line on Lot ~-~'~/~/,~/v/<~A ; Date /0// ,, / B. SEPTIC/HOLDING TANK DATA Date Installed '~ Standpipes (Y/N)// Depression over Tank (Y/N) Size ./"~'/~ No, of Compartments ¢ Air-tight Caps (Y/N) Y Foundation Cleanout (Y/N) ~ Date Last Pumped lO/'~/'~/~s Y Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) Separation Distances from Septic/Holding Tank: To Water-Supply Well '~.~2~/74. TO Property Line ~'~17L' TO Water Main/Service Line Course ~ Comments ;for Temporary Holding Tank Permit (Y/N) To Building Foundation To Disposal Field To Stream, Pond, Lake, or Major Drainage Page I of 2 72-026(11/84) ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed Width of Field Square Feet of Absorption Area Depression over Field (Y/N) Results of Last Adequacy Test ( Separation Distance from Absorption Field: TO Water-Supply Well /~--¢~(7/1E Type of System Design Length of Field ~--~ ,~ ,._ ..z ~, Depth of Field ~Z 7 ~ _ Gravel Bed Thickness 0~/I Standpipes Present (Y/N) Date of Last Adequacy Test To Properly Line ~ ~ To Existing or Abandoned System on ; On Adjoining Lots ,~ To Cutbank (if present) ~ / To Building Foundation Lot //0/'~ To Water Main/Service Line /~/?L To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified¢/r conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed Y~t'c~Cf~'/ Date Company -- MOA No. ' Date of Payment /~/[~ ~"~ Page 2 of 2 72-026 (11/84)