The subject permit, issued June 29, 1994 by this office for a
single family well and/or on-site wastewater system, has
expired as of June 29, 1995.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as-built inspection report must be sent to this office for
review, approval and documentation. Ail inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
Sin~rely,
J es Cross,
Jp~o;Sram Manager
On-site Services
enc:
Copy of Permit
cc: DHI Engineering
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH A1YD HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM
PERMIT NUMBER:SW940214
DESIGN ENGINEER:DHI ENGINEERING
OWNER NAME:HORRELL FAMILY PARTNERSHIP
OWNER ADDRESS:9950 PROSPECT DRIVE
ANCHORAGE, AK
PAGE 1 OF 1
(UPGRADE) PERMIT
DATE ISSUED: 6/29/94
EXPIRATION DATE: 6/29/95
PARCEL ID:01001611
LEGAL DESCRIPTION: T13N R4W SEC 25 SE4NE4NE4
LOT SIZE: 88465 (SQ. FT.)
~ER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 (24 HOURS)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
THE MBXIMUM TOTAL ~TH F~T~EM SH~LL BE 8 FT.
RECEIVED BY: ~, ~_ DATE:
ISSUED BY: ~~l ~ DATE:
'Permff No. ,
On-Site Wastewafer Disposal
Legal Description: 905 WEST 52nd AVENUE
Munlc~pall~ of Anchorage
Department of Health and Human Services
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 =Anchorage, AK 99519-6650 =Tel: 545-4744
System/Well
Page 1 of 5
W.O. 94126
Date 5-51-94
Inspection Report
PID No.
SITE NARRATIVE
PARCEL No. 1 (905 W. 52ND) IS A 2.3 ACRE TRACT BOARDER ON
THE EAST BY ARCTIC BLVD. & TWO LARGER PARCEL ON THE NORTH
& SOUTH. THESE LARGER TRACTS ARE SERVICED BY MUNICIPAL
(PUBLIC SEWER & WATER). AFTER REVIEW OF THE COST OF
EXTENDING PUBLIC SEWER TO THIS PARCEL, DHHS (JOHN
SMITH) AGREED THAT ON SITE SEPTIC SYSTEM WOULD BE
ACCEPTABLE
WELLS:
THE AREA IS SERVICE BY PUBLIC WATER (MOA).
WASTE GENERAL SYSTEM:
THE AREA IS SERVICED BY PUBLIC SEWER.
DRAINAGE:
THE LOT SLOPES GENTLY TO THE SOUTH WEST.
THERE ARE NO DRAINAGE CHANNELS OR CREEKS
ON THE PROPERTY. ALL FINISH GRADE WILL BE
SLOPED TO DRAIN. ALL DISTURBED SOIL WILL
RECEIVE TOP SOIL & WILL BE SEEDED.
Permit No. ,
Municipalify of Anchorage
Deporfmenf of Heolfh and Human Services
ENVIRONMENTAL SERVICES DIVISION
Page 2 of 5
W.O. 94126
Dote 4-16-94
P.O. Box 196650 'Anchorage, AK 99519-6650
On-Site Wasfewafer Disposal System/Well
Legal Description: 905 WEST $2nd AVE
'Tel: 343-4744
Inspection Report
PID No.
SYSTEM DESIGN CALCULATIONS
1. NO. BEDROOMS = 4
2. USE TRENCH SYSTEM
3. ABSORBTION AREA = (# BEDROOMS)(150 GPD/BR)
TRENCH APPLICATION RATE
= (4)(15o) = 6oo sF
4. TRENCH AREA ~- (WIDTH)(LENGTH) = 600 SF
IF WIDTH OF GRAVEL -- 5'
THEN LENGTH OF TRENCH -- 120'
USING 4' DEPTH YIELDS MAXIMUM LENGTH
REDUCTION OF 50%
THEREFORE TOTAL LENGTH = 60'
USE TRENCHES, ,30' EACH.
PERCOLATION RATE
PIT & TRENCH
APPLICATION RATE
MOUND & BED
APPLICATION RATE
MIN/INCH OPD/SF GPD/SF
0-1 NOT SUITABLE NOT SUITABLE
1-5 1.2 0.8
6-15 0.8 0.5
16-50 0.6 0.4
31-60 0.45 0.3
OREATER THAN 60 NOT SUITABLE NOT SUITABLE
· t SAND QUALIFIES AS FILTER LAYER i,0 I .7
**.~ OF'
DATE
~ermit No. ,
On-Site
Legal Description:
Municipality of Anchorage
Department of Health and Human Services
ENVIRONMENTAL SERVICES DIVISION
P.O, Box 196650 ,Anchorage, AK 99519-6650-Tel: 545-4744
Wasfewoter Disposal System/Well Inspection
905 WEST $2nd AVENUE
Page 3 of 5
Date 5-,31-94
Report
,Permi} No. ,
On-Site
Municipality of Anchorage
Department of Health and Human Services
ENVIRONMENTAL SERVICES DIVISION
P.O. ]]ox 196650 ° Anchorage, AK 99519-6650' Tel: 343-4744
Wastewater Disposal System/Well Inspection
Legal Description:
Page 4 of
W.O. 94126
5-31-94
Dale
905 WEST 32nd AVENUE
5
Report
PID No.
BACKFILL
SEE NOTE
GEOTEXTILE FABRIC
SEE NOTE 11
SEWER ROCK PER
MUNICIPAL SPECS
SEE NOTE 9
7'
COVER
°Qo Q~
0{3° 2~
4"¢ MONITOR TUBE W/
AIRTIGHT CAP
SLOPE FILL TO DRAIN
SEE NOTES 13
EXISTING GRADE = 109.0±
TOP ELEV.= 109.0±
SLOPE TRENCH WALLS
SEE NOTE 8
ORGANIC
SILTS
4" ¢ PERF. PVC PIPE
INVERT = 102.6 (-0.5)
4,0' GRAVEL BELOW
PiPE INVERT
SAND W/
GRAVEL
BOTTOM
6'+
OF GRAVEL = 98.6 (-4.5')
T.P. #1
17'
· ( ) WEST LEACH
FIELD DESIGN DATA
BOTTOM OF TEST PIT
ELEV = 92.0±
TYPICAL WIDE TRENCH SECTION
SCALE: NTS
Page 5 of 5
Permit No. W.O. 94126
Legal Description: 905 WEST 3;Snd AVENUE Date 5-5~-94
NOTES:
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CHAPTER 15.65. WASTEWATER DISPOSAL REGULATIONS
OF THE MUNICIPAL CODE AS CURRENTLY AMENDED.
2. CONTRACTOR TO EXPOSE BOTH EXISTING 4" SERVICE LINES AT HOUSE & VERIFY IN VERT OF PIPES. NOTIFY
ENGINEER IF INVERT ELEVATION DIFFER FROM PLANS.
.3. SITE TOPOGRAPHIC SURVEY CONDUCTED BY DHI ON 5-10-94. EXISTING STRUCTURES, WELLS AND SEPTIC
SYSTEMS OBSERVED WITHIN 200 FT. OF THE PROPOSED SYSTEM SITE ARE SHOWN ON DESIGN DRAWINGS.
4-. ANY DEVIATION FROM THE DESIGN MUST BE AUTHORIZED BY THE ENGINEER PRIOR TO ITS INCORPORATION
INTO THE SYSTEM.
5. CONTRACTOR TO LOCATE ALL UNDERGROUND UTILITIES, PROPERTY LINES, EXISTING WELLS, WATERWAYS,
SURFACE AND SUBSURFACE DRAINAGE FACILITIES, LAKES, PONDS, AND OTHER FACILITIES REQUIRING
SEPARATION DISTANCES FROM THE PROPOSED SEPTIC SYSTEM. CONTRACTOR SHALL STAKE PROPOSED SYSTEM
PRIOR TO CONSTRUCTION. NOTIFY THE ENGINEER OF ANY OBSERVED CONFLICTS PRIOR TO CONSTRUCTION.
6. CONTRACTOR TO NOTIFY THE ENGINEER AND DHHS 24 HOURS PRIOR TO COMMENCING WITH CONSTRUCTION. '
A MINIMUM OF THREE INSPECTIONS ARE REQUIRED. THE FIRST INSPECTION SHALL BE OF THE SUBGRADE
PRIOR TO PLACING THE SEWER ROCK. THE SECOND INSPECTION SHALL BE AFTER THE PLACEMENT OF
GRAVEL, DISTRIBUTION PIPING, STANDPIPES, TANK, AND OTHER COMPONENTS AS SPECIFIED. THE THIRD
INSPECTION SHALL BE AFTER THE WORK iS COMPLETED.
7. CONTRACTOR SHALL DELIVER TO THE ENGINEER A SET OF RED-LINED, AS-BUILT DRAWINGS SHOWING ALL DATA
AS SPECIFIED IN SEC. 15.65.F.2, .3, 4, 5, 6 OF MUNICIPAL WASTEWATER DISPOSAL CODE WITHIN FIVE DAYS OF
THE FINAL INSPECTION, INVERTS AND SWING TIE LOCATES SHALL BE TO THE NEAREST TENTH OF A FOOT.
THESE AS-BUILTS SHALL BE USED BY THE ENGINEER TO PREPARE AND SUBMIT RECORD DRAWINGS TO DHHS.
8. EXCAVATE THE ABSORPTION TRENCH. BO~FOM & SIDES OF EXCAVATION SHALL BE LEVEL AND SCARIFIED.
RECORD ELEVATIONS AT BEGINNING, MIDDLE, AND END OF TRENCH BOTTOM, CONSTRUCTION EQUIPMENT
SHALL NOT OPERATE ON THE FLOOR OF THE EXCAVATION. ANY MATERIAL COMPACTED BY THE OPERATION
OF CONSTRUCTION EQUIPMENT SHALL BE REMOVED AND REPLACED WITH UNCOMPACTED MATERIAL. SLOPE OR
SHORE TRENCH WALLS TO CONFORM TO ALL FEDERAL, STATE & LOCAL SAFETY STANDARDS.
9. PLACE THE SEWER ROCK TO THE SPECIFIED DEPTHS. DO NOT CONTAMINATE SEWER ROCK WITH NATIVE MATERIAL
OR SPOILS FROM EXCAVATION. LEVEL ROCK SURFACE TO J: 1" PRIOR TO INSTALLING THE PERFORATED PIPE.
lO. ALL PIPE SHALL BE PVC CONFORMING TO ASTM D5054. MINIMUM SOIL COVER SHALL BE 4 FEET OVER THE
PiPE AND SEPTIC TANK. ONE INCH OF INSULATION MAY BE SUBSTITUTED FOR 1 FOOT SOIL COVER. ALL
INSULATION BOARD SHALL BE 2" THICK DOW HI-35 INSULBOARD OR ENGINEER-APPROVED EQUAL. CENTER
INSULBOARD WIDTH OVER SEPTIC TANK,
11. COVER THE DISTRIBUTION PIPE WITH MIN 2" SEWER ROCK, AND COVER WITH GEOTEXTILE BEFORE PLACING
INSULATION AND BACKFILL. GEOTEXTILE SHALL BE MIRAFI 140S. LAP ALL JOINTS 2' MIN.
12. MATERIAL USED AS FILL SHALL BE CLEAN AND FREE OF ORGANICS, TRASH AND CONSTRUCTION DEBRIS.
13. SLOPE ALL FILL MATERIAL TO DRAIN AT 2% MIN. SLOPE, AND 5:1 MAX SLOPE, AND IN SUCH A MANNER THAT
PONDINO AT OR NEAR THE DRAIN FIELD DOES NOT OCCUR. THE FILL SHALL BE LEFT AT 6" HIGHER THAN
SHOWN TO ALLOW FOR SETTLEMENT. SEED SURFACE AFTER COMPLETING INSTALLATION AS PER MUNICIPAL SPECS.
RECORD THE FINISH GROUND ELEVATION OVER THE BEGINNING, MIDDLE, AND END OF THE TRENCH.
14, CONTRACTOR TO DIG 17' DEEP TEST PIT TWO WEEKS PRIOR TO COMMENEING WITH CONSTRUCTION. ENGINEER TO LOG TEST PiT, CONDUCT PERCOLATION TEST & MONITOUR WATER TABLE FOR 10 DAYS. LEACH FIELD & TANK
TO BE CONSTRUCTED ONLY AFTER ENGINEER OBTAINS APPROVAL OF DHHS. DEPTH OF SYSTEM MAY VARY
TO OBTAIN NECESSARY COVER OVER TOP OF TANK PIPE & LEACH FIELD.
PERFORMED FOR:
LEGAL DESCRIPTION:
1
2
3
4
5
6
7
8
9
tO
11
12
13
14
15
16-
17-
18-
19-
20-
COMMENTS
(ENGINEER'S SEAL
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
DATE PERF(
WAS GROUND WATER
ENCOUNTERED?
Township, Range, Section: 7'-/.-~
SLOPE SITE PLAN
IF YES, AT WHAT
DEPTH?
Depth to Water After
Monitoring? / ?.
Gross Net Depth to Net
Reading Date
Time Time Water Drop
PERCOLATION RATE __
(minutes/inch) PERC HOLE DIAMETER __
TEST RUN BETWEEN __FTAND FT
/ /,
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
(ENGINEER'S SEAL}
PERFORMED FOR: [~ ~:~ ~"J~o ~ t:~ ~ ~'~-
DATE
LEGAL DESCRIPTION:
1
4-
5-
6-
7
8
9-
10-
11
13-
14-
15-
16-
17-
18-
19-
20-
COMMENTS
Township, Range, Section:
SLOPE
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH? {/'~ p
E
Depth to Water Alter
Meflitoring? /z.~, '7 Date:
~c ,2..5
SITE
Gross Net Depth to Net
Reading Date
Time Time Water Drop
/ ~-~-¢,¢ ,o.'~v,,/,o.~, 1.5 'Y/~.~-~ ~'- 7~"
2- ,o~cHo.'~r ;,t ~.~ I'1
~ ,, ,,..~/~,..z¢ ~ ~/~ ~.~
PERCOLATION RATE (~. z¢',~ (minutes/inch) PERC HOLE DIAMETER ~ u
~EST RUN BETWEEN ~/ ~TAND~Y'~- F~
PERFORMED BY: ¢~' ~'~¢ I ~ ~i~ CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDeLiNeS IN EFFECT ON THIS DATE, DAT~: ~' ~ - ~ ~
/
72-008 (Rev. 4/~)
June 22, 1994
W.O. 94126
Mr. Jim Cross
Department of Health & Human Services
P.O. Box 196650
Anchorage, Alaska 99519-6650
RE: Septic System Design Approval / Parcel No. 1 T13N R4W Section 25
Dear Jim,
Enclosed are the revised design drawings for the above referenced project. With regard to
our telephone conversation, I have redesigned the system for 600 gallons per day (4 bedroom
single family residence). I have split the system into two leach fields. Therefore, I have
assumed 200 gallons per day to each leach field.
Based on our previous soils investigation, I believe the soils on the lot to be very uniform.
Therefore, I am requesting that we receive design approval to construct contigent upon the
engineer digging another test hole and conducting another percolation test to verify the soils
at the location proposed for the westerly leach field.
Should any thing change from the design as approved, we will contact you for approval prior
to proceeding with actual construction.
Very truly yours,
DeeHigh, P.E. // ,/
Principal (.~.~
Enclosure
126dj21u
PO Box 111349 Anchorage, Alaska 99511-1349 · (907) 345-1385/Fax 345-1386
~-28-1994 12:56PM FROM D HI ONSULTING TO 3436?40 P.01
ivil yl Planning
FAX MEMORANDUM
FAX NO. .~.~ .~ ~'~ q~> W.O. NO,
ATTENTION: ~ ', ,,,,.
SUB.IBcTr: f~:~.~, ~w~kx NO. OF PAG~
TRANSMI~D:~
~ FOR YO~ I~O~ATION:
~lgi~ Oi~os~tion: ~ M~il~ ~ ~l for ~up ~
M~SAGE:
,,, ~ ~k ~
... ~e9%' , , . .
PO Bo,~ 1~ 1349 Aneh,.':~g'e. Ah),~kl~ .99a11-1~49 * (907) 345-13811/Fax 34.5-1i386
06-28-1994 12:5?PM FROM D HI ONSULTING
DHI Engineering
P.O. Box 111349
Anchorage, Alaska 99511-1349
Attention: Mr. Carl Abrams
Subject: Particle-Size Analysis
Job #94 ! 26
Dear Mr. Abrams:
The particle-size distribution of your soil was.measured in the laboratory. The published methods for
this test are:
ASTM C 117, "Material Finer Than 75-pm (No. 200) Sieve in Mineral Aggregates by Washing;"
e ASTM C 136. 'Sieve Analysis of Fine and C~ar~e Aggregat~;"
· ASTM D 422, "Particle Size-Analysis of Soils;"
* AASHTO T-I I, "Materle{ Finer Than 75-pm Sieve in Mineral Aggregates;"
AASHTO T-27, "Sieve Analysis of Fine and Coarse Aggregate~;"
AASHTO %30, "Mechanical Analysis of Extracted Aggregate;"
· AASHTO T -88, "Particle $iz~ Analysis of Soils;" and
AK DOT/PF ATM T-7, "Sieve Analysis of Fine and Coa~ Aggregates,"
Alaska Testlab's standard procedure is in conformance with these standards, with the~ following
descriptions:
* Tho coarse fraction of non-extracted soils {s not washed unle~ rite coarse particles appear to b~ s!~nificantly coated
with fine~;
* The fine fi'action of the soil ia always washed; .
· The plus 3-fnch fraction is not routinely incled~d in lhe test due to the large sample mass required for a representative
sample; The estimated plereentage of pins 3 inch material in the sampl~ is shown on the test report; hnd :
e The mass of the coarse and fine teat fractions are reported.
The soil is classified in accordance with ASTM D 2487, "Classification of Soils for Engineering
Purposes (Unified Soil ClassifiCation System)." The fi~ast classification is identified in accordance
with Corps of Engineers and Municipality of Anchorage (MOA) procedures.
The test results are attached. If you have any questions regarding the test proce'dures or ihe :~ults,
plea.~ call.
Sincerely,
ALASKA TESTLAB
How0xd K. Weston,
Technical Director
·
ins'd..i
lO B GTREET · ANCHQRAGE * ALASKA · ggSD3-5999 · 9071582-2000 * FAX; gD7/563-3953
06-28-1994 12:5?PM FROM D HI ONSULTING
TO
mm,:O'o
0~#
.~q~!aA~ ,~q ~ulsS~d lua;Ma~
TOTAL P.03