INSPECTION REPORT ON-SITE SEWAGE DISPOS. AL SYSTEM
SEPTIC TANK:
DISTANCE
FROM WELL,.~?
INSIDE LENGTH
MANUFACTURER
INSIDE WIDTH
MATERIAL
NUMBER OF
COMPARTMENTS
LIQUID DEPTH
LIQUID CAPACITY / ~ GALLONS.
LINING MATERIALC/~/~//I~': CRIB SIZE:
.UlLDING FOUNDATION '~/,
DIAMETER DEPTH DrSTANCE FROM: WELL
NEAREST LOT LiNE /0 TOTAL EFFECTIVE
ABSORPTION AREA (WALL AREA) ~' SQ. FT.
ADDITIONAL ABSORPTION
WELL:
TYPE CONSTRUCTION
BUILDING NEAREST
FOUNDATION LOT LINE
CESSPOOL OTHER SOURCES
APPROVED DISAPPROVED
NEAREST
SEWER LINE
REMARKS
DEPTH DISTANCE FROM:
SEPTIC SEEPAGE
TANK SYSTEM
DISTANCES:
DIAGRAM OF SYSTEM
LOT SLOPE:
REMARKS:
0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0
PERMIT NO.
DEPARTMENT ' HERLTH AIN[:, ENVIRONMENTRL ROTEI]:TION
825 '"L" STREET, ANCHORRGE, RK. 9;~501.
~PPLIC:FINT
L. OCR]"ION
L. EG~L
LESTER SMITH.
FOOTHILL [:,R
L.i OF Lil SEC ±2 T:t4N
E:O'X 83 E. R.
LOT SIZE
694-23:69
]:4225 SQI.JRRE FEET
'¥"¢PE OF SOIL flBSORBTION SVSTEM IS: TRENCH
NUMBER OF' BEDROOMS = ~:
SOIL RRTING (SQ FT/BR)= i50
THE REQUIRED SIZE OF THE SOIL RBSORPTION S'¢STEM IS:
THE LENG]'H DIMENSION IS THE L. ENGTH (IN FEET) OF 7'PIE TRENCH OR DRRINFtELD.
THE DEPTH OF R TRENCH OR PIT IS THE DISTRNCE BETWEEN THE SURFRCE OF THE
GROUND RND THE BOTTOM OF THE Ek.',CR'v'RTION (IN FEET).
]"HERE IS NO SET WIDTH FOR TRENCHES.
THE GRRVEL DEPTH IS THE MINIMUM DEPTH OF GRR',,,'EL BETWEEN THE OUTFRLL PIPE
FIND THE BOTTOM OF THE E'XCRVRTION (IN FEET).
6'RE:KFILLING OF RN9 SVSTEM WITHOUT FINRL INSPECTION RND RPPRO'v'RL BY THIS
DEPRRTMENT WILL BE SUBJECT TO PROSECUTION.
MINIMIJM L I=1'MNLE BETblEEN A WELL FIND AN"r' ON-SITE SEb. IRGE DISP]SflL z,r.z, TEM IS
:L00 FEET FOR R PRIVRTE WELL OR 200 FEET FOR A PUBLIE: WELL.
SPEC]:FICRTIONS RIND CONSTRUCTION DIRGRRt'IS ARE RVFtIL.RBLE TO INSURE PROPER
INSTALLATION.
t
±:
FOR]'H B"r' THE MUNICIPRLIT"r" OF RNCHORRGE.
2: I WILL INSTRLL THE S"r'STEM IN FICCORDRNCE WITH THE CODES.
2;: t UNDERSTRND THRT THE ON-SITE SEWEF:: S"r'STEM MR? REt.]UIRE
RES I[:,ENCE~EMODELE[:, TO I NCLU[:'E MORE THFtN ]: E:E[?ROOMS.
RPPL I CRNT LESTER SMITH
i _,_,UE.[ ............. DflTE .........
CERTIFV THR]'
I RM FRMILIRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS RS SET'
ENLFtI~'.GEI'dEI'.,IT IF TIdE
08-E
Russe# OVster
694 2774
Soils ~ Foundations
Performed for:
GEO'~ ~'CHNI CAL Er DEVEL~- PMENT CO.
Box 90, Davis St, Eagle River, Alaska 99577
694-2774 or 688 P~2_80
SOIL LOG
Ear/£///s
688-2280
Land Development
Tel. No.~
Soil Cha~rac_ _~
Yes_ ._~ No~ If yes, what depth_~
i6
Ground Water Encountered:
Proposed Installation: Seepage Pit _~Drain Field~_
Comments: '~"~-~' . , ~".,. k,.'~e ~',J. ~ ~
CERT
Municipality of Anchorage
'Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 BEagaw, S~e~t
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
FICATE OF ON-SITE SYSTEMS
FOR A SINGLE FAMILY
Parcel I.D. 05027`309
1. GENERAL INFORMATION
APPROVAL
DWELLING
ffctr~c,.~ O~P 1017-q7
COSA# 05CiOl~-~ff
Expiration Date: 2 - 1-//
Complete legal description
Location (site address)
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
, Mailing address
T14N, R2W, SEC12, LOT 1 OF 11
17122 FOOTHILL * EAGLE.RI~/ER, AK * 995.77 ...............
MICHELLE SCHILLING Day phone 696-4410
17122 FOOTHILL * EAGLE RIVER, AK * 99577
Day phone
VICTORIA BRINK W/ KELLER WILLIAMS Day phone 551-94,34-
101 W BENSON BLVB. SUITE 50`3 *ANCHORAGE, AK 9950`3
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well · Individual On-site ·
Individual Water Storage [] Individual Holding tank []
Community Class Well [] Community On-site []
Public Water System [] Public Sewer []
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As cerlified by my seal affixed hereto and as of the validation date shown below, t verify that my
investigation, based on procedures outlined in the CertifiCate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from t,~e Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd.
Phone 337-6179
Address .5701 E. TUDOR ROAD, SUITE.101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Date
Engineer's Comments:
In conducting this evaluation, GEG, LtD. attempted to provide a thorough,
conscientious engineerin~j'bnMySis.of the system in accbrdance with ADEC and MOA ~
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
DSD SIGNATURE
~Approved for -~
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following stipulations:
Attachments: COSA Checklist
Septic System Advisory
Well Flow Advisory
(Rev.
Arsenic Advisow
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
CERTIFICATE OF 0N-S1-¢ 7: S APPROVAL
Legal Description:
WELL DATA
Well type PRIVATE
Date completed
Total depth i20
T14N, R2W, SEC 12, LOT 1 OF 11
6/18/86
ff.
IfA, B, or C provide PWSID# N/A
SanitarY seal (Y/N) YES
Cased to
FROM WELL LOG
Date of test 6/18/86
Static water level 80
Well production 10
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mi.
Arsenic: ND ug./L.
120 ft.
g.p.m.
Nitrate 0.126 mg./L.
Date of sample: 10/5/2010
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material SEPTIC/STEEL
Tank size 1000 gal, Number of Compartments
Foundation cleanout (Y/N) YES
Date of pumping I 0 J /5 ]! o
CHECKLIST
Parcel ID: 05027309
Well Log (Y/N)
Wires properly protected (Y/N)
Casing height (above ground)
AT INSPECTION
10/6/2010 ·
69 .ft.
5.03 g.p.m.
YES
YES
12+ in.
Other bacteria 0 colonies/100 mi.
Collected by: GE(;; Ltd.
Date installed **'7/12/77
2 Cleanouts (Y/N) YES
Depression over tank (Y/N) NO High water alarm (Y/N) N/A
Pumper JR'S PUMPING
ABSORPTION FIELD DATA
Date installed **'7/:12/77
Length 20+30=50 .ft.
Total depth*17/17.8 ft. Eft. absorption area 800 ft2 Monitoring tube YES
Date of adequacy test: *'10/6/2010 Results (Pass/Fail) PASS
ISOUTH/NORTH TRENCHI
I'BELOW EXISTING GRADE TO Bo'FrOM OF WHAT ARE ASSUMED TO BE SUMPS I
Soil rating (g.p.d./ft2o~, 150 System type DUAL DEEP TRENCHES
Width 3. ft. Gravel below pipe 8 ft.
'Depression over field NO
For 3 bedrooms
Fluid depth in absorption field before test 10 in.
Elapsed Time.: 225 min. Final fluid depth 10
Any rejuvenation treatment (past 12 mo.) (YIN & type) **SOUTH TRENCH TESTED.
Water added 655 gal. New depth 1 6 in.
in. Absorption rate >= 450+ g.p.d.
NONE KNOWN If yes, give date -
PRESOAKED WITH 2210 GALLON OF WATER ON. 10 0.
D. LIFT STATION
Date installed
"Pump on" level at
Datum ~
E.
in.
Size in gallons Manhole/Access (Y__~_) ~
"Pump off" leveL.aL-------inT-'"-- High water alarm level at
Cycles tested Meets alarm & circuit requirements?
SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
'79'+
Septic tank/lift station on lot
Absorption field on lot 100'+
Public sewer main N/A
Sewer/septic service line 25'+
Animal containment areas 50'+
,in.
On adjacent lots *96'+
On adjacent lots '79'+
Public sewer manhole/cleanout
Holding tank N/A
Manure/animal excrete storage areas
N/A
100'+
Water service line
Curtain drain NONE
COMMENTS
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+
Water main N/A Water service line 10'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'.+
10'+
KNOWN
*SEE ATTACHED
Absorption field 5'+
Surface water. 100'+
NORTH TRENCH/SOUTH TRENCH
Building foundation **UNKNOWN Water main N/A
Surface water 100'+ Driveway, parking/vehicle storage
Wells on adjacent lots. '93'+
1'+
WAIVER REQUEST. **RELATION OF SOUTH TRENCH TO GARAGE SLAB UNKNOWN.
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA ,COSA guidelines in effect on this
date.
Engineer's Printed Name JEFFREY A. GARNESS
Date
COSA Fees
Date of Payment
Receipt Number
(Rev. 11/05)
Waiver Fee $
Date of Payment
Receipt Number
AS-BUILT
I hereby certify that I have s~eyed the folloveln§ described
property,:, iL, o ?' ~' ~ "' '~'" "~ ' ' :',.-,i
:, ~ ..,,.. ,; ~,,.. .~? ,
:,,, .... .: i .... . ,.e..... J'7-.-.: "i"! ~..~, ;l,j'
. . . . ,, x. k-"' ..?/':';'~
AneZorage Reco. rding Precinct, Alaaka, and that the imp. rove-
om~m? ~itua~ed me?on .? within ~he F~ope._n~ lines and ~io not
~ap or en~oacn on me property Iy~g adjacent thereto, that
onn° .,m~prove-m. en~ on pro. p~ 1.y~g adjacent thereto enctbach
nrne premises m quesaon and [hat there am rte roadways,
transmission tines or other v~ible easeme_~ts on said
~xcept as indicated hereon.
Dated ~t Eagle River, AlasI~
ROBERT C, }OHNSON : ...... .
SCALE: Registered Ln_nd Smvevo~ No. I~80-LS
i" = .~. ~' BOx 77-0456, Eagle R~v&r, Alaska 99577
Phone (907) 694-2543
SGS ReL# 1105359001
Client Name Garness Engineering Group, Ltd Printed Date/Time 10/08/2010. 16:44
Project Name/# T14N,R2W,SEC12,L1 OF 11 Collected Date/Time 10/05/2010 11:45
Client Sample ID T14N,R2W,SEC12,L1 OF 11 Received Date/Time 10/05/2010 12:45
Matrix Drinking Water , Technical Director Stephen C. Ede
Sample Remarks:
Allowable Prep Analysis
Parameter Results LOQ Units Method Container ID Limits Date Date Init
Metals by ICP/MS
Arsenic ND 5.00 ug/L EP200.8 C (<10)
10/05/10 10/06/10 KDC
Waters Department
TotalNitrate/Nitrite-N 0.126 0.100 mg/L SM20 4500NO3-F B (<I0) 10/05/10 AYC
Microbiology Laboratory
E. Coli Ne~;ative I 100mL SM20 9223B A 10/05/10 DLC
Total Coliform Negative I 100mL SM20 9223B A 10/05/10 DLC
ARCTIC PUMP & WELL INC.
Jim Sullivan, CPI
PO Box 770197
Eagle River, AK 99577
(907) 658-2510
(907) 258-2510
apw~gci.net
Pump Installation Log
Well Drilling Permit Number: SW
Parcel Identification Number:
Date of Issue:
Legal Description: T 14N R2W S12
Lot: 1 of 11
Block:
Property Owner Name & Address:
Michelle Schilling
10023 Chandalar St
l~'~ol~ Rix~r AI~
Pump Installation Date: 10/14/2010
Pump Intake Depth Below Top of Well Casing:
Feet
Pump Manufacturer's Name:
Pump Size:
Pump Model:
hp
Pitless Adapter Burial Depth:
Pitless Adapter Manufacturer's Name:
Pitless Adapter Installer:
feet
Arctic Pump & Well, Inc.
Well Disinfected Upon Completion? Yes
Method of Disinfection: Chlorine
Comments:
Well permanently decommissioned by procedurel 5.55.060L. c.
Pump Installer Name:
Arctic Pump & Well, Inc.
Arctic Pump & Well, Inc.
Page 1 o fl
Municipality of Anchorage
P.O. Box 196650 · 4700 Elmore Road
Anchora,qe, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997
http:llwww.muni.or,qlOnsite
Development Services Department
On-Site Water and Wastewater Pro.qram
partment
**** VARIANCE/WAIVER REVIEW ****
WR#: OSP101247 HAft: OSi:::101265
PIDft: 050-273-09.
Legal Description: T14N R2W Sec12 Lot I of 11
Engineer: GEG
Permit/C:
Applicant: David Schilling
Your request for multiple waivers regarding the subject property's well and septic system has
been approved. The waivers are approved as detailed below.
1. 79 foot separation distance from the subject property's well to subject property's septic
tank.
2. 79 foot separation distance from the subject property's well to the drainfield on Smart Lot
1.
3. 96 foot separation distance from the subject property's well to the septic tank on Smart
Lot 1.
4. 93 foot separation distance from the subject property's drainfield to the well on T14N
R2W Sec. 12 Lot 4 of 11.
This waiver approval applies to the specific separation distances as detailed above. Any future
upgrade to the on-site wastewater disposal system will require all separation distances be met or
another approval from this department.
Waiver is Granted: X Waiver is not Granted:
1.~1~1~ App db eY' '~ 'Sf Reviewer
Recft: 090976 Amount: $1050 Date Paid: 10/22/10
**** VARIANCE/WAIVER REVIEW ****
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS :,,~:::~ :~;', ,, ~
October 22, 2010
Municipality of Anchorage
Development Service Department
On-Site Water & Wastewater Program
4700 Bragaw Street
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
Ref: Multiple Waiver Requests for T14N, R2W, Sec 12, Lot 1 of 11,
To whom it may concern:
Properties Well to Properties Septic Tank:
The existing 3 bedroom house is served by a private well and septic system. During our site investigation
work to obtain a COSA, we discovered that the well on the subject proPerty is only 79 feet away from the
existing 1000 gallon septic tank on the subject property. We request you grant an-8-1-~ot separation
distance waiver from the well on the referenced property to the septic tank. The following items are
justification for the waiver:
· The well and septic system are on opposite sides of the house. If effluent were to surface, it would be
unable to travel towards the well head.
· The existing encroachment has existed for over 24 years.
· Attached is the well log for the referenced property. The well depth is 120 feet. The soil appears to be
variations of clay, gravel, & sand.
· The lawn is neatly groomed, so if the tank were to overflow, the effluent would be obvious and the
problem would be addressed immediately.
· We are only asking for a 21% variance.
· Recent water samples results indicated no bacteria present and nitrate levels to be 0.126 mg./L. In short,
the water quality is within MOA, state, and EPA requirements.
Properties Well to Adjacent ProperW (Stuart Lot 1) Absorption Field & Septic Tank:
The existing 3 bedroom house is served by a private well and septic system. During our site investigation
work to obtain a COSA, we discovered that the well on the subject property is only 79 feet away from the
absorption field & 96 feet away from the septic tank located on the adjacent property (Stuart Lot 1). We
request you grant a 79 foot & 96 foot separation distance waivers from the well on the referenced
property to the absorption field & septic tank on the adjacent lot. The following items are justification for
the waiver:
· The existing encroachments have existed for over 24 years.
· Attached is the well log for the referenced property. The well depth is 120 feet. The soil appears to be
variations of clay, gravel, & sand.
· The lawn is neatly groomed, so if the tank and/or drainfield were to overflow, the effluent would be
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
obvious and the problem would be addressed immediately.
.We are only asking for a 21% variance & a 4% variance..
*Recent water samples results indicated no bacteria present and nitrate levels to be 0.126 mg./L. In short,
the water quality has not been adversely impaired by this encroachment.
Properties Absorption Field to Adjacent Properties Well (T14N R2W Sec 12 Lot 4):
The existing 3 bedroom house is served by a private well and septic syStem. During our site investigation
work to obtain a COSA, we discovered that the well on the subject property is only 93 foot away from the
absorption field on the adjacent property (T14N, R2W, Sec 12, Lot 4). We request you grant a 93 foot
separation distance waiver from the well on the referenced property to the absorption field on the adjacent
lot. The following items are justification for the waiver:
*The well and septic system are on opposite sides of the driveway. If effluent were to surface, it wou
very obvious to the homeowners and they would be able to address the problem immediately.
.The existing encroachment has existed for over 24 years.
*We were unable to locate any other well logs except for the one for our referenced lot (T14N, R2W
12, lot 1 of 11) which is attached to this waiver request. The well depth is 120 feet. The soil appears
variations of clay, gravel, & sand.
'.The lawn is neatly groomed, so if effluent were to overflow, the effluent would be obvious an,
problem would be addresSed immediately.
*We are only asking for a 7% variance.
*Recent water samples results indicated no bacteria present and nitrate levels to be 1.48 mg./L. In
the water quality has not been adversely impaired by this encroachment.
We are unaware qf any adverse impacts this would have on adjacent wells or septic systems fro~
granting of these x~aivers. If you have any questions, please contact us at 337-6179. Thank you for
assistance.
i
x~f~f ~ ~.~G'~,l~essi P.E., M.S.
mre~/t7 ~
ld be
, Sec
to be
the
lOrt,
the
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
- F o o~-h-TL~--A v e n u e
I
~ / T14N R2W SEC 12
I
~T 1 ~TUART LOT J
,
~ SCALE: ~GLE RIVER RO~
MICHELLE SCHILLING 276-4665 I 1 or 1 ~¢'..~e~freyA. G~,'
WAIVER REQUEST 10/19/2010
(Rev. 01/05)
// .- GREATER ANCHORAGE AREA BOROUGH
'3330 "C" Street., Anchorage, Alaska 99503 274-4561
~ / j~ ~~ Date Received June 21, 1976
u .....
-J~ '. Time of Inspection 2:30 p.m.
~ Date of Inspection ?-Z-?6 ~e~Ze
REQUEST FOR APPROVAL OF Thursday
INDIVIDUAL SEWER & WATER FACILITIES
FOR
1. Approval requested by:
3,
4.
.5.
'6.
Mailing Address:
Property Owner:
Mailing Address:
Area Inc. % Myrna Johnston
Post Office Box 249, Ea~e River Phone: 694-9555
Lester L. Smith Phone: 694-2369
Post Office Box 83
Legal Description: T14N R2W Section 12 Lot 1 of 11
Location:
Type of facility to be inspected Single Family
Well Data: Individual
A. Type
C. Construction
Sewage Disposal System:
A. Installed B. Installer
C. Septic Tank: 1. Size 2. Manufacturer
D. Seepage Pit: 1. Absorption Area 2. Material
E. Disposal Field: Total length of lines
~eet Myrna at the Area Realty Ea~le River office.
No. of bedrooms
, Absorption area
Distances:
A. Well to: Septic tank
Nearest lot line
B. Foundation to septic tank
.C. Absorption area to nearest lotline
B. Depth
D. Bacterial Analysis
, Other contamination
, Absorption area
, Sewer Lines
EQ-034 (1/74) Page 1 of two pages
1
2.
333p
Department of Envi ronme~.tal qual i t~UNIClPALITY
'C" St.~ Anchorage Alaska 99503 27aDq)~(~HEA~TH&
~ ENViRONmeNTAL PROTECTION;
REOUEST FOR APP2OVAL OF
]~I~FJ~L×~WATER' FACILITIES
Type of Ins'pectio.~:
JUN 3 1 1976
VA FHA CONV
Propewty Owner: ~$~
~.0. ~o× 83
Mailing Address: ~agle ~lver, ~ 99577
3. Name of Buyer: ~/~
NailipQ Address:
~. 2ame of Lending Institution: ~/A
Da.y Phone
694-2369
e
Day Phone
-,
Mailing Address:
Name of Realtor or Agent:
Phone
,Myrna Johnston, Area, Inc. Realtors
'Mailing Address:
P.O. Box 249
Eagle River, AK
Legal Description:' - T14N
Location: Approximately
Phone 694-9555
99577
R2W Sec 12 Lot 1 of 11
1 mile E.R. Rd. turn"l.eft one street
short of .Genora St. whit~ w/qreen trim
Type of Facility to be inspect'ed:
~later Supplyi, .(only)
Type '~f S~pply: PuSli'c
-2nd house on riqht. -'. ,.'
.- N01 Bd~msl
Individual x ' ....... '
Utility
dWelli'ngS, pre'sexily se~ed 1 '
If' Individual','number of
If Individual, depth of well
Sewage Disposal'System
Type,of S~stem: Public Utility
'~ndividual (on-site)
_.If..Ind~v'idual, date of installation
Rea~to~ will have key
page 2 of two pages - Re~-~t for Approval of Individual .?-Aer & Water Facilities
'Legal Description
T14N R2W Section 12 Lot 1 of tl
Comments:
Approved
Disapproved Date ~l~,~i
Approval~Valid for one year from date signed
Greater Anchorage Ar~a Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
I certify that the information contained in this request for approval to be a true and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED
Date
EQ-034 (1/74)