HomeMy WebLinkAboutT14N R2W SEC 12 LT 1 OF 11TI4N R2W 12 Lot I of 11 050- 273 -09 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP261060 Work Type: SepticTank Upgrade Tax Code Number: 05027309000 Site Legal Address: T14N R2W SEC 12 LT 1 OF 11 G:0052 Site Mailing Address: 17122 FOOTHILL AVE, Eagle River Owner: DEBUSK KEITH K Design Engineer: FORGE ENGINEERING This permit is for the construction of: ❑ Disposal Field Z Septic Tank ❑ Holding Tank ❑ Privy Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 4/23/2026 4/23/2027 27225 Non -Public ❑ Water Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Coodinate with On -Site staff regarding preferred method. 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: Waiver OSV101247 was previously issued for a 79' separation from the subject property's well to the septic tank on property. This waiver is hereby renewed and granted a separation distance of 81.5' from the proposed tank to the existing water well. Issued To: FORGE ENGINEERING Date: 4/23/2026 Issued By: Curtis Townsend Date: 4/23/2026 3 MUNICIPALITY OF ANCHORAGE 1+ C� Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 050-273-09 Property owner(s) Keith Debusk Day phone (907)242-9097 Mailing address 17122 Foothill Ave, Eagle River, AK 99577 Site address Same Legal description T14N R2W SEC 12, Lot 1 Number of Bedrooms 3 Engineering Firm Forge Engineering Building Permit Number Not Applicable 0 APPLICATION IS FOR: APPLICATION IS AN: (N all that apply) Disposal Field ❑ Initial ❑ Septic Tank R. Upgrade 0 Holding Tank ❑ Renewal ❑ Privy ❑ Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Septic tank to well separation Permit/Rush Fees: Z 2 �_ Waiver Fees: Date of Payment: Permit No. G S (' Z L f 0 6 Date of Payment: Waiver No. Distance: 81.5' May 2025 April 23, 2026 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: T14N R2W SEC 12, Lot 1 – 17122 Foothill Ave Septic system design Dear On-Site Services Engineer: The owner of the above lot owns a 3-bedroom home on the property. The existing septic tank has collapsed and is in need of immediate replacement, so we are submitting this permit application for the installation of a new septic tank. The attached site plan identifies the location of the home as well as the proposed tank location. The proposed tank location is 81.5 feet from the existing well, while the current tank is located 79 feet from the well and was previously granted a waiver. This system has been in place for nearly 50 years with no adverse impacts. The location of the existing buildings in relation to the piping to the drainfield does not allow the tank to be placed outside the well radius. Also, the most recent water sample, taken in 2010, showed nitrate levels of 0.126 mg/L with no coliform detected, well within acceptable limits. It is for these reasons we request a waiver for the proposed tank. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from surface water, and more than 5’ away from the existing drainfields. Please refer to the attached plan page for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261060, Curtis Townsend, 04/23/26 Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 1"=50' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND T14N R2W SEC 12, LOT 1 FEET 0 50 100 SEPTIC PLAN 4/22/26 2CO REMOVE EXISTING SEPTIC TANK EXISTING DRAINFIELDS TO REMAIN IN SERVICE (EXISTING WAIVER TO NEIGHBORING WELL) NEW 1000-GAL SEPTIC TANK. ENSURE 10' FROM FOUNDATION EXISTING WELL (TYP) NEIGHBORING SEPTIC (EXISTING WAIVER TO NEIGHBORING WELL) 81.5 NO RECORDS. CONFIRM LOCATION OF EXISTING WELL IS 100' FROM PROPOSED TANK DURING INSTALL Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP261060, Curtis Townsend, 04/23/26 A 0 4�d GREA,-ER ANCHORAGE AREA BOk,..dGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOS. AL SYSTEM SEPTIC TANK: DISTANCE FROM WELL,.~? INSIDE LENGTH MANUFACTURER INSIDE WIDTH MATERIAL NUMBER OF COMPARTMENTS LIQUID DEPTH LIQUID CAPACITY / ~ GALLONS. LINING MATERIALC/~/~//I~': CRIB SIZE: .UlLDING FOUNDATION '~/, DIAMETER DEPTH DrSTANCE FROM: WELL NEAREST LOT LiNE /0 TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ~' SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE CONSTRUCTION BUILDING NEAREST FOUNDATION LOT LINE CESSPOOL OTHER SOURCES APPROVED DISAPPROVED NEAREST SEWER LINE REMARKS DEPTH DISTANCE FROM: SEPTIC SEEPAGE TANK SYSTEM DISTANCES: DIAGRAM OF SYSTEM LOT SLOPE: REMARKS: PERMIT NO. DEPARTMENT ' HERLTH AIN[:, ENVIRONMENTRL ROTEI]:TION 825 '"L" STREET, ANCHORRGE, RK. 9;~501. ~PPLIC:FINT L. OCR]"ION L. EG~L LESTER SMITH. FOOTHILL [:,R L.i OF Lil SEC ±2 T:t4N E:O'X 83 E. R. LOT SIZE 694-23:69 ]:4225 SQI.JRRE FEET '¥"¢PE OF SOIL flBSORBTION SVSTEM IS: TRENCH NUMBER OF' BEDROOMS = ~: SOIL RRTING (SQ FT/BR)= i50 THE REQUIRED SIZE OF THE SOIL RBSORPTION S'¢STEM IS: THE LENG]'H DIMENSION IS THE L. ENGTH (IN FEET) OF 7'PIE TRENCH OR DRRINFtELD. THE DEPTH OF R TRENCH OR PIT IS THE DISTRNCE BETWEEN THE SURFRCE OF THE GROUND RND THE BOTTOM OF THE Ek.',CR'v'RTION (IN FEET). ]"HERE IS NO SET WIDTH FOR TRENCHES. THE GRRVEL DEPTH IS THE MINIMUM DEPTH OF GRR',,,'EL BETWEEN THE OUTFRLL PIPE FIND THE BOTTOM OF THE E'XCRVRTION (IN FEET). 6'RE:KFILLING OF RN9 SVSTEM WITHOUT FINRL INSPECTION RND RPPRO'v'RL BY THIS DEPRRTMENT WILL BE SUBJECT TO PROSECUTION. MINIMIJM L I=1'MNLE BETblEEN A WELL FIND AN"r' ON-SITE SEb. IRGE DISP]SflL z,r.z, TEM IS :L00 FEET FOR R PRIVRTE WELL OR 200 FEET FOR A PUBLIE: WELL. SPEC]:FICRTIONS RIND CONSTRUCTION DIRGRRt'IS ARE RVFtIL.RBLE TO INSURE PROPER INSTALLATION. t ±: FOR]'H B"r' THE MUNICIPRLIT"r" OF RNCHORRGE. 2: I WILL INSTRLL THE S"r'STEM IN FICCORDRNCE WITH THE CODES. 2;: t UNDERSTRND THRT THE ON-SITE SEWEF:: S"r'STEM MR? REt.]UIRE RES I[:,ENCE~EMODELE[:, TO I NCLU[:'E MORE THFtN ]: E:E[?ROOMS. RPPL I CRNT LESTER SMITH i _,_,UE.[ ............. DflTE ......... CERTIFV THR]' I RM FRMILIRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS RS SET' ENLFtI~'.GEI'dEI'.,IT IF TIdE 0 Et E GEM __CHNI CAL Et DE.VIEL�.. ,-'MENT CO. Box 90, Davis St., Eaale River, Alaska 99577 694-2774 or 688-2280 Russell Ovster Earl Ellis 694-2774 SOIL LOG 68f3-2280 Soils Et Foundations Land Development Performed for: Name: Tel. No.'�" Mal l i rya Addresses' Leaal pescriotion: Depth feet Soil mCharacteristics I 3 5 6 7 12 13 _ ,. _ j 14 ti L1-� ,,. A F'k 15 `3 - > kxo k> t� : ,��j ,,�_ v,(l �,:� a �►.��;� r� r� '1 ,I, 1 �\ 4✓\�j1.��"V� �> �/� 'ice AT_6 �/ L� "/ Water Encountered: Yes No If yes, what depth s Proposed Installation: Seepage Pit Drain Field r` Comments: - ��j�,a�� _'_7 �;� _ ��, k'.��v 3' r; V Performed byY: _,� v'r�' �a �,. ��� Date: lhOunicipality of Anchorage Fir • Development Services Department Building Safety Division .: k I On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON -SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING votr'tAnce- 05 V 1�12�t7 Parcel I.D. 05027309 COSA# 1. GENERAL INFORMATION Expiration Date: I Complete legal description T14N R2W SEC12 LOT 1 OF 11 Location -(site address) 117122__FOOTHILL * EAGLE RIVER AK * 99577 Current Property owner(s) MICHELLE SCHILLING Day phone Mailing address Lending agency Mailing address Real Estate Agent Mailing address 17122 FOOTHILL * EAGLE RIVER AK * 99577 Day phone VICTORIA BRINK Wj KELLER WILLIAMS Day phone 696-4410 351-9434 101 W BENSON BLVD. SUITE 503 *ANCHORAGE. AK 99503 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On -site 0 Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On -site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on -site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As cerlified by my seal affixed hereto and as of the validation date shown below, t verify that my investigation, based on procedures outlined in the CertifiCate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from t,~e Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address .5701 E. TUDOR ROAD, SUITE.101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineerin~j'bnMySis.of the system in accbrdance with ADEC and MOA ~ DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. DSD SIGNATURE ~Approved for -~ Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory (Rev. Arsenic Advisow Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite CERTIFICATE OF 0N-S1-¢ 7: S APPROVAL Legal Description: WELL DATA Well type PRIVATE Date completed Total depth i20 T14N, R2W, SEC 12, LOT 1 OF 11 6/18/86 ff. IfA, B, or C provide PWSID# N/A SanitarY seal (Y/N) YES Cased to FROM WELL LOG Date of test 6/18/86 Static water level 80 Well production 10 WATER SAMPLE RESULTS: Coliform 0 colonies/100 mi. Arsenic: ND ug./L. 120 ft. g.p.m. Nitrate 0.126 mg./L. Date of sample: 10/5/2010 B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Tank size 1000 gal, Number of Compartments Foundation cleanout (Y/N) YES Date of pumping I 0 J /5 ]! o CHECKLIST Parcel ID: 05027309 Well Log (Y/N) Wires properly protected (Y/N) Casing height (above ground) AT INSPECTION 10/6/2010 · 69 .ft. 5.03 g.p.m. YES YES 12+ in. Other bacteria 0 colonies/100 mi. Collected by: GE(;; Ltd. Date installed **'7/12/77 2 Cleanouts (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Pumper JR'S PUMPING ABSORPTION FIELD DATA Date installed **'7/:12/77 Length 20+30=50 .ft. Total depth*17/17.8 ft. Eft. absorption area 800 ft2 Monitoring tube YES Date of adequacy test: *'10/6/2010 Results (Pass/Fail) PASS ISOUTH/NORTH TRENCHI I'BELOW EXISTING GRADE TO Bo'FrOM OF WHAT ARE ASSUMED TO BE SUMPS I Soil rating (g.p.d./ft2o~, 150 System type DUAL DEEP TRENCHES Width 3. ft. Gravel below pipe 8 ft. 'Depression over field NO For 3 bedrooms Fluid depth in absorption field before test 10 in. Elapsed Time.: 225 min. Final fluid depth 10 Any rejuvenation treatment (past 12 mo.) (YIN & type) **SOUTH TRENCH TESTED. Water added 655 gal. New depth 1 6 in. in. Absorption rate >= 450+ g.p.d. NONE KNOWN If yes, give date - PRESOAKED WITH 2210 GALLON OF WATER ON. 10 0. D. LIFT STATION Date installed "Pump on" level at Datum ~ E. in. Size in gallons Manhole/Access (Y__~_) ~ "Pump off" leveL.aL-------inT-'"-- High water alarm level at Cycles tested Meets alarm & circuit requirements? SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: '79'+ Septic tank/lift station on lot Absorption field on lot 100'+ Public sewer main N/A Sewer/septic service line 25'+ Animal containment areas 50'+ ,in. On adjacent lots *96'+ On adjacent lots '79'+ Public sewer manhole/cleanout Holding tank N/A Manure/animal excrete storage areas N/A 100'+ Water service line Curtain drain NONE COMMENTS SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Water main N/A Water service line 10'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'.+ 10'+ KNOWN *SEE ATTACHED Absorption field 5'+ Surface water. 100'+ NORTH TRENCH/SOUTH TRENCH Building foundation **UNKNOWN Water main N/A Surface water 100'+ Driveway, parking/vehicle storage Wells on adjacent lots. '93'+ 1'+ WAIVER REQUEST. **RELATION OF SOUTH TRENCH TO GARAGE SLAB UNKNOWN. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA ,COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date COSA Fees Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS :,,~:::~ :~;', ,, ~ October 22, 2010 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Ref: Multiple Waiver Requests for T14N, R2W, Sec 12, Lot 1 of 11, To whom it may concern: Properties Well to Properties Septic Tank: The existing 3 bedroom house is served by a private well and septic system. During our site investigation work to obtain a COSA, we discovered that the well on the subject proPerty is only 79 feet away from the existing 1000 gallon septic tank on the subject property. We request you grant an-8-1-~ot separation distance waiver from the well on the referenced property to the septic tank. The following items are justification for the waiver: · The well and septic system are on opposite sides of the house. If effluent were to surface, it would be unable to travel towards the well head. · The existing encroachment has existed for over 24 years. · Attached is the well log for the referenced property. The well depth is 120 feet. The soil appears to be variations of clay, gravel, & sand. · The lawn is neatly groomed, so if the tank were to overflow, the effluent would be obvious and the problem would be addressed immediately. · We are only asking for a 21% variance. · Recent water samples results indicated no bacteria present and nitrate levels to be 0.126 mg./L. In short, the water quality is within MOA, state, and EPA requirements. Properties Well to Adjacent ProperW (Stuart Lot 1) Absorption Field & Septic Tank: The existing 3 bedroom house is served by a private well and septic system. During our site investigation work to obtain a COSA, we discovered that the well on the subject property is only 79 feet away from the absorption field & 96 feet away from the septic tank located on the adjacent property (Stuart Lot 1). We request you grant a 79 foot & 96 foot separation distance waivers from the well on the referenced property to the absorption field & septic tank on the adjacent lot. The following items are justification for the waiver: · The existing encroachments have existed for over 24 years. · Attached is the well log for the referenced property. The well depth is 120 feet. The soil appears to be variations of clay, gravel, & sand. · The lawn is neatly groomed, so if the tank and/or drainfield were to overflow, the effluent would be 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com obvious and the problem would be addressed immediately. .We are only asking for a 21% variance & a 4% variance.. *Recent water samples results indicated no bacteria present and nitrate levels to be 0.126 mg./L. In short, the water quality has not been adversely impaired by this encroachment. Properties Absorption Field to Adjacent Properties Well (T14N R2W Sec 12 Lot 4): The existing 3 bedroom house is served by a private well and septic syStem. During our site investigation work to obtain a COSA, we discovered that the well on the subject property is only 93 foot away from the absorption field on the adjacent property (T14N, R2W, Sec 12, Lot 4). We request you grant a 93 foot separation distance waiver from the well on the referenced property to the absorption field on the adjacent lot. The following items are justification for the waiver: *The well and septic system are on opposite sides of the driveway. If effluent were to surface, it wou very obvious to the homeowners and they would be able to address the problem immediately. .The existing encroachment has existed for over 24 years. *We were unable to locate any other well logs except for the one for our referenced lot (T14N, R2W 12, lot 1 of 11) which is attached to this waiver request. The well depth is 120 feet. The soil appears variations of clay, gravel, & sand. '.The lawn is neatly groomed, so if effluent were to overflow, the effluent would be obvious an, problem would be addresSed immediately. *We are only asking for a 7% variance. *Recent water samples results indicated no bacteria present and nitrate levels to be 1.48 mg./L. In the water quality has not been adversely impaired by this encroachment. We are unaware qf any adverse impacts this would have on adjacent wells or septic systems fro~ granting of these x~aivers. If you have any questions, please contact us at 337-6179. Thank you for assistance. i x~f~f ~ ~.~G'~,l~essi P.E., M.S. mre~/t7 ~ ld be , Sec to be the lOrt, the 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com - F o o~-h-TL~--A v e n u e I  ~ / T14N R2W SEC 12 I ~T 1 ~TUART LOT J , ~ SCALE: ~GLE RIVER RO~ MICHELLE SCHILLING 276-4665 I 1 or 1 ~¢'..~e~freyA. G~,' WAIVER REQUEST 10/19/2010 (Rev. 01/05) ,1 Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road %f Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 httP://www.muni.org/Onsite Development Services Department On -Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** W R#: 05 V 101247 P I D#: 050-273-09 HAM OSC101265 Permit#: Legal Description: T14N R2W Sec12 Lot 1 of 11 Engineer: GEG Applicant: David Schilling Your request for multiple waivers regarding the subject property's well and septic system has been approved. The waivers are approved as detailed below. 1. 79 foot separation distance from the subject property's well to subject property's septic tank. 2. 79 foot separation distance from the subject property's well to the drainfield on Stuart Lot 1. 3. 96 foot separation distance from the subject property's well to the septic tank on Stuart Lot 1. 4. 93 foot separation distance from the subject property's drainfield to the well on T14N R2W See.12 Lot 4 of 11. This waiver approval applies to the specific separation distances as detailed above. Any future upgrade to the on -site wastewater disposal system will require all separation distances be met or another approval from this department. .................. 0 0 E a a 0 0 a 0 0 0 0 ...... 0 0 0 N a M 0 0 0 2 00 0. 0 ... 0 ... E\ 0 E a a 0 M .. 0 0 0 2 0 0 0 0 0■. Waiver is Granted: X Waiver is not Granted: Date: 10/28/10 Approved by - Name of Reviewer .................... 0 0 0 0 E x ......... 4 0 0 M a 0 0 0 M .■ ............ \ ... \ 0 a N 0 E 0 t 2 a 0 N a■. Rec#: 090976 Amount: 1050 Date Paid: 10/22/10 **** VARIANCE[WAIVER REVIEW **** JjkJelln e c.) 01 -Z3 : if , Tn'; ko T, ..... .. ...... AS -BUILT I hereby certify that I , have surveyed the following described property. !"'i 17. Anchorage Recording Pre6mct, Alaska, and that the improve- ments; situated thereon are within the property lines and do not overlap or &-ncrQach on the property lying adjacent thereto, that no Impmvements on lying adjacent thereto enerbach on the PMP" ying in question and that there are no roadways, transmission or other visible easements on said property except as indicated hereon. Dated at Ea -le River, Alaska rG - this l . Iay of ROBIERT C. JOITNSON Registered Land Surveyor or No- 880-LS 'Box 77-0456, Eagle River, Alaska 99577 Phone (907) 694-2543 ARCTIC PUMP & WELL INC. Jim Sullivan, CPI Ham'— �,- PO Box 770197 arnrn rsr�s mrrrf sufs s RAW Eagle River, AK 99577 (907) 688-2510 (907)258-2510 apwrgdnet Pump Installation Log Well Drilling Permit Number: SW Parcel Identification Number: Date of Issue: Legal Description: T 14N R2W S12 Property Owner Name & Address: Lot:I of 11 Michelle Schilling Block: 10023 Chandalar St Fav1P Ri-vpr AK 94577 Pump Installation Date: 10/14/2010 Pump Intake Depth Below Top of Well Casing: Feet Pump Manufacturer's Name: Pump Model: Pump Size: hp Pitless Adapter Burial Depth: feet Pitless Adapter Manufacturer's Name: Pitless Adapter Installer: Arctic Pump & Well, Inc. Well Disinfected Upon Completion? Yes Method of Disinfection: Chlorine Comments: Well permanently decommissioned by procedure15.55.060L.c. Pump Installer Name: Arctic Pump & Well, Inc. Arctic Pump & Well, Inc. Page 1 of 1 // .- GREATER ANCHORAGE AREA BOROUGH '3330 "C" Street., Anchorage, Alaska 99503 274-4561 ~ / j~ ~~ Date Received June 21, 1976 u ..... -J~ '. Time of Inspection 2:30 p.m. ~ Date of Inspection ?-Z-?6 ~e~Ze REQUEST FOR APPROVAL OF Thursday INDIVIDUAL SEWER & WATER FACILITIES FOR 1. Approval requested by: 3, 4. .5. '6. Mailing Address: Property Owner: Mailing Address: Area Inc. % Myrna Johnston Post Office Box 249, Ea~e River Phone: 694-9555 Lester L. Smith Phone: 694-2369 Post Office Box 83 Legal Description: T14N R2W Section 12 Lot 1 of 11 Location: Type of facility to be inspected Single Family Well Data: Individual A. Type C. Construction Sewage Disposal System: A. Installed B. Installer C. Septic Tank: 1. Size 2. Manufacturer D. Seepage Pit: 1. Absorption Area 2. Material E. Disposal Field: Total length of lines ~eet Myrna at the Area Realty Ea~le River office. No. of bedrooms , Absorption area Distances: A. Well to: Septic tank Nearest lot line B. Foundation to septic tank .C. Absorption area to nearest lotline B. Depth D. Bacterial Analysis , Other contamination , Absorption area , Sewer Lines EQ-034 (1/74) Page 1 of two pages 1 2. 333p Department of Envi ronme~.tal qual i t~UNIClPALITY 'C" St.~ Anchorage Alaska 99503 27aDq)~(~HEA~TH& ~ ENViRONmeNTAL PROTECTION; REOUEST FOR APP2OVAL OF ]~I~FJ~L×~WATER' FACILITIES Type of Ins'pectio.~: JUN 3 1 1976 VA FHA CONV Propewty Owner: ~$~ ~.0. ~o× 83 Mailing Address: ~agle ~lver, ~ 99577 3. Name of Buyer: ~/~ NailipQ Address: ~. 2ame of Lending Institution: ~/A Da.y Phone 694-2369 e Day Phone -, Mailing Address: Name of Realtor or Agent: Phone ,Myrna Johnston, Area, Inc. Realtors 'Mailing Address: P.O. Box 249 Eagle River, AK Legal Description:' - T14N Location: Approximately Phone 694-9555 99577 R2W Sec 12 Lot 1 of 11 1 mile E.R. Rd. turn"l.eft one street short of .Genora St. whit~ w/qreen trim Type of Facility to be inspect'ed: ~later Supplyi, .(only) Type '~f S~pply: PuSli'c -2nd house on riqht. -'. ,.' .- N01 Bd~msl Individual x ' ....... ' Utility dWelli'ngS, pre'sexily se~ed 1 ' If' Individual','number of If Individual, depth of well Sewage Disposal'System Type,of S~stem: Public Utility '~ndividual (on-site) _.If..Ind~v'idual, date of installation Rea~to~ will have key page 2 of two pages - Re~-~t for Approval of Individual .?-Aer & Water Facilities 'Legal Description T14N R2W Section 12 Lot 1 of tl Comments: Approved Disapproved Date ~l~,~i Approval~Valid for one year from date signed Greater Anchorage Ar~a Borough, Department of Environmental Quality DIAGRAM OF SYSTEM I certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ-034 (1/74)