HomeMy WebLinkAboutT14N R1W SEC 28 Tract A
POU,. ,: 6-650
ANCHORAGE, ALASKA 99502-0650
(907) 264-4111
TONY KNOWLES
MA YOR
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
Permit #: 840586
January 31, 1985
TO: Permit Applicant
SUBJECT: T14N R1W Section 28 Tract A
A permit issued by this Department for an individual well
and/or on-site sewer system has expired as of December 31,
1984.
Permits are issued on a calendar year basis by authority
of Municipal Ordinance. A new permit must be obtained from
this Department for any well and/or on-site sewer system not
installed by the expiration date.
If you have drilled the well, a well log needs to be sent
to this Department for documentation of the installation
and to close the permit.
If a private engineer inspected the installation of the
on-site sewer system, the original as-built inspection report
and the yellow copy must be sent to this office for review
and approval, and for documentation.
If there are any further questions, please call this office
at 264-4720.
Sincerely,
rKeith E. Bandt, Supe~viso
Environmental Engineering Program
KEB/ljw
eric: Copy of Permit
SWP/057
DEPARTMEN~ OF HEALTH ANI~ ENVIRONMENTAL F'ROTECTION ~
825 L STREET.,, ANCHORAGE., AK 9950l
264=4720 ~ '
TE SENER ~ NELL. F"ERHIT,
PERMIT NO:
DATE ISSUED:
APPLICANT:
ADDRESG:
CONTACT PHONE:
840586
07/17/84
SOUTH FORK-CONST.
S&S ENGINEERING
EAGLE RIVER~ :AK 99577
694-2979
LEGAL DESCRIP:
LOT SIZE:
MAX BEDROOMS:
SUBDIVISION: TRACT A LOT: NA
SECTION: 28 TOWNSHIP: 14N RANGE: 1W
200A (SQ.FT. 8R ACRES)
3
BLOCK: NA
Listed below are the options available to you in designing your septic
system. Choose the option that best fits your site.
TREe, CH BED ~. B,F:AIN
DEPTH TO PIPE BOTTOM (FT.) 4.0 4.0 4.0
GRAVEL DEPTH (FT.) 5.0 0.5 5.5
TOTAL DEPTH (FT.) 9.0 4.5 7.5
GRAVEL WIDTH (FT.) 2.5 26.0 5.0'
GRAVEL LENGTH (FT.) 105.~ ~ 50.0 115.0
GRAVEL VOLUME (CU.YDS.) 53.4 48.1 83..7'
TANK SIZE (GALS) 1,000.0 *'~ 1~-000.0 ~ 1~000.0
SOIL RATING (SQ.FT./BR) 549 284 549
GRAVEL LENGTH > 75 FT. REQUIRES. MOLTIPLE RUNS (NO~ EXCEEDIN8 75 FT. EACH)
TANK MUST HAVE AT LEAST TWO COMPARTMENTS
certiIy that:
1. I am £amiliar wi{h the requirements for on-site sewers and wells as set
forth by,the Municipality of Anchorage (MOA) and the State o£ Alaska.
2. I will install the system in accordance with all MOA cedes and regulations~
and in compliance with the design criteria o£ this permit.
3. I will adhere to all MOA and State o¢ Alaska requirements for the set back
distances £rom any existing well, wastewater disposal system or public
sewerage system on this or any adjacent or nearby lot.
4. I understand that. this permit is valid Cot a maximum of 3 bedrooms and
any enlargement will require an additional permit.
IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY b10A BUILDING coDEs,
THEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS=QUILTS
WILL. NOT BE APPRQV~D~ITHOUT AN ELECTRICAL INSPECTION REPORT; AND (3) THE
ELErCTRICAL WORI<~NOST t~E DONE BY~ LICENSED ELECTRICIAN. / /
ISSUED BY' ~~~ DATE=
.... ~--~-~--~--~ ............................ ? ..... : ..... ~--~---~--
~'-"~ '~-% [] SOILS LOG
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L, Street, Anchorage, Alaska 99501 264-4720
SOILS LOG - PERCOLATION TEST
PERCOLATION
TEST
PERFORMED FOR:
LEGAL DESCRIPTION:
1
2
3
4
5
6
7
8
9
10
11
12
13--
14
15
16
17
18
19-
'0 _
COMMENTS
WAS GROUND WATER ~ SE
ENCOUNTERED? ~ O
P
E
IF YES, AT WHAT
DEPTH?
Gross Net Depth to Net
Reading Date Time Time Water Drop
i'~ I'~---~ Reading
~'" ' PERCOLATION RATE ~ (minutes/inch)
TEST RUN BETWEEN ~ , FT AND ~G FT
PERFORMED BY: · SRB 19~X
~' JP~, 694-297@
72-008 (6/79)