HomeMy WebLinkAboutT13N R3W SEC 28 Lot 14
Anchorage
POUCH b-o50,
ANCHORAGE, ALASKA 99502
(907) 279-2511
GEORGE M. SULLIVAN,
MAYOR
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
(825 "L" Stleet )
blarch 21, 1979
Donald Wilson
4121 Laurel Street
Anchorage, Alaska
99504
Subject: T13N R3W Section 28 Lot 14
Approval can not be granted on the above subject property,
for the following reasons:
(1) The sewer system does not have a septic tank.
(2)
There are two(2) cesspools on the property. The
first one being less than the required one-hundred(100)
foot separation between well and a leaching area. The
second cesspool was not located and will need to be,
so that we can determine if the separation between it
and the well is adequate.
(3) The well is in a cement pit with the casing below grom~d
level.
In order for'you to get approval on the subject property,
the following must be completed:
(1)
Install~ a 1,000 gallon septic tank, fifty(50) feet
from your well.
(2) Cave in. and abandon the cesspool nearest the well. Cave
in and abandon the second cesspool if it is within
one-hundred(100) feet of the well.
(3)
If the second cespool is one-hundred(100) feet or more
from the well, it should have an adequacy test performed.
See enclosed handout.
Mr. Wilson
March 21, 1979
Page Two
(4) If the adequacy test does not meet this department's
criteria, an upgrade of the system will be required.
(5) The well casing must be extended twelve(12) inches
above ground level.
If there are any further questions, please contact this
office at 264-4720.
Sincerely,
Robert C. Pratt, R.S.
Associate Specialist
RCP/ljw
cc: Nancy Bergh
101 East International Airport Road 99502
Ray Walker
101 East International Airport Road 99502
MUNICI Y OF ANCHORAGE DEPT. OF I:~ALrH &
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL E,,,bzECT[ON
825 L Street- Anchorage, Alasga 09B01 MAR ~ 4/979
ENVIRONMENTAL ENGINEERING DIVISION
Telep.o.e 264-4720 RECEIVED
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
)IRECTIONS: Complete ali parts on page 1. Incomplete requests wil~ not be proce~ed. Please allow ten [10) days for processing.
1. PROPERT OWNER , PHONE
PROPERTY RESID~T {If different from abovel PHONE
2. BUYER PHONE
MAI LING ADDR ESS
3. LENDING INSTITUTION I PHONE
E. LEGAL DESCRIPTION
STREET LOCATION
6. TYPE OF RESIDENCE NUMBER OF BEDROOMS
[] One [] Four
D~'~Si NG LE FAMILY [] Two [] Five
[] MULTIPLE FAMILY I~ Three [] Six
[] Other
7. WATER SUPPLY
~ INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled
[] COMMUNITY since June 1975. For wells drilled prior to that date, give well
[] PUBLIC UTI LITY depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
~ iNDiVi DUAL/ON_SiTE~
E~3 PUBLIC UTILITY
**If individual/on-site, give installation date
If system is over two (2) years old an adequacy test is required
by this Department.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010(3/78)
THIS SIDE FOR OFFICIAL USE ONL't
DATE RECEIVED
INSPECTION APPOINTMENTS
TIME TIME TIME
DATE DATE DATE
iNSPECTOR INSPECTOR INSPECTOR
DIRECTIONS:
1. TYPE OF RESIDENCE NUMBER OF BEDROOMS
[] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
PERMIT NUMBER
2, WATER SUPPLY
[] INDIVIDUAL DEPTH OF WELL
[] COMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
[]INDIViDUAL/ON -SITE DATE INSTALLED
[]PUBLIC UTILITY
Connection Verified INSTALLER
[]Septic Tank or [] Holding Tank
Size: If Tank is homemade SOILS RATING
give dimensions:
TYPE OF TANK MANUFACTURER
TOTAL ABSORPTION AREA MATERIAL
4. DISTANCESwELL TO: Septic/Holding Tank Absorption Area Sewer Line I Nearest Lot Line
Absorption Area to nearest Lot Line
[] APPROVED FOR BEDROOMS
[] CONDITIONAL APPROVAL (letter must accompany certificate)
[;i~,'~DI SAPP R OV E D
DATE BY (Title)
LEGAL DESCRIPTION