Loading...
HomeMy WebLinkAboutT13N R3W SEC 26 Lot 17 GAAB-HO I HEALTH DEPARTMENT 327 EAGLE ST. ANCHORAGE, ALASKA 99501 279~2511 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATI~DN ~/~,/9~,ff-~' '~4/'~///,.~.'~I/~.(_,,~LEGAL DESCRIPTION ,~~7 ..~~--~ SEPTIC TANK: ' ' ~+ J~ ~.,~ "~ ~ NUMBER OF DEPTH SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS i OUTSIDE DIAMETER ORWIDTH /7~., LENGTH 1~, DEPIH~'~ LINING MATERIAL /('~5 ,,,,ANCE FROM WELL ~¢//~ -'¢~ ~'~- . ~ , BUILDING FOUNDATION ~ . TOTAL EFFECTIVE ABSORPTION AREA (WAIL AREA} ~ SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELl TOTAL LENGTH FOUNDATION NEAREST LOT LINE , OF LINES NUMBER OF LINES DISIANCE BETWEEN LINES TRENCH qlDI~H IN. TOTAL EFFECTIVE ABSORPTION AREA SQ. FT. LENGTH OF EACH LINE DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATER AL BENEATH TILE· C/ J~ //~ DISTANCE FROM 7 WATER I/ WELL: TYPE ,-" ~""! LJL¢ , DEPTH .' r¢~,BUILDING FOUNDAIION, · SAMPLE , SEWER LINE ,TANK . SYSTEM ~ ~ ' ~-' CESSPOO[ LOT LINE j IN. ABOVE IILF NEAREST OTHER ~ SOURCES DISTANCES: (' DIAGRAM OF SYSTEM DATE APPROVED // ~ HEALTN AU[HORI[? ' GREATEI ANCHORAGE AREA ROUGH HEALTH DEPARTMENT 327 Eagle St. Anchorage, Alaska 99501 279-2511 Case No. SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT NAME OF APPLICANT RESIDENCE ADDRESS LEGAL DESCRIPTION APPLICATION TO INSTALL: SEPTIC TANK MAILING ADDRESS //,~<,:/~ '~' PHONE NO.~'~' LOCAT'0" 0F,,STALLAT'0N SEEPAGE PIT ~, DRAIN FIELD , OTHER TO SERVE THE FOLLOWING FACILITY ~ ,~ FINANCED THROUGH ~-Z"'I TO BE INSTALLED BY THIS IS TO SERVE AS -~:~' , PERMIT TO INSTALL A AS DESCRIBED BELOW. SIZE OF UNIT TO BE SERVED ,- · SEPTIC TANK SIZE /~0 ~ TYPE~ ~ . SEEPAGE AREA TYPE DISTANCES: DIAGRAM OF SYSTEM Authority- I certify that I am familiar with the requirements of Greater Anchorage Area Borough Ordinance No. 28-68 and that the above described system is in accordance with said code. DATE APPLICANTS SIGNATURE July 24, 1969 Mrs° ttelen M. Fogel 1340 Blrchwood Anchorage~ Alaska Dear Mrs. Fogel: This is to confirm a conversation with you on tile morning of Wednesday, July 23, 1969 in which I indicated to you that your property Indicated as Lot 17 of Sectlon 26 In the Muldoon area of the Greater An( ~rage Area Borough was located in the proximity of a sewer now under construc- tion by the borough, but would still remain approximately 660 feet from this trunk ¥~hen It is completed during the late summer of this construc~- tion season. I further indicated to you that the trunk sewer proposed for construction In Trunk Improvement District No. 4 presently scheduled for public hearing on August 4, 1969, and construction during the construction year 1970/71 would com~ within 350 feet of your property and be more accesslbte, and was designed and provtded as a drainage system for your property. This office wlll work with you in any way possible to provide adequate sanitary sewer service to your property during the up--coming construction If I can assist you further tn this regard, please advise. - - Yours very truly, GREATER ANCHORAGE AREA ~OROUGH Robert H. Morrlss, P. E. Director of Public Works R~4/~k cc: Mr. Roll Strickland