Loading...
HomeMy WebLinkAboutT15N R1W SEC 6 Lot 56 NAME MAI LING ADDRESS ~ MUNICIPALITY OF ANCHORAGE DEPARTMEN~E OF HEALTH & ENVIRONIV1ENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT P~ LEGAL DESCRIPTION LOCATION DISTANCE TO: Liq, capacity in gallons ~, Manufacturer NO. OFBEDROOMS PERMIT NO. Liquid dep~_ /~)E~ CD IF NOMEMADE Well PERMIT NO. DISTANCE TO: Manufacturer Material Liquid capacity in gallons l Absorption area [ Dwelling I0 / Material I Inside length Width Foundation ~¢'0¢ t Nearest lot hne Total length of ines Material beneath tile Depti~ Well DISTANCE TO: No. of lines Length of each lille] / Top of tile to finish grade z Length Width Type of crib Crib diameter PERMIT NO. Distance between lines Total effective 8bs rption 81'ea PERMI] NO. Crib depth Total effective absorption area Building foundation Nearest lot line ~ h-~-e ---T~'E-R M I T NO. Driller /~ Sewer lille ( I Septic tank ¢' I Absorption area(s) 7 '0~, _L____-¢- 6x-;~ .-L Well DISTANCE I O: Building foundatiod DISTANCE TO: OTHER PIPE MATERIALS SOl L TEST RATI I~G INSTALLER REMARKS DATE ~. LEGAL PERMIT NO. FIPPL I CRNT L. CIC:RT I ON LEGAL DEPRRTMENT Or HERLTH 8ND ENVIRONMENTRL PROTECTION s~REET., RNCHORRGE., BK. 995~1 ] 264-4.~20 OFJ--':5 Z T[~ SE~IIER PERPI Z 'T D&S UNLIMITED ~ 7800 DEBRRR ~206 1_~ S6 TiSN RIW SM · -,, 6t LOT SIZE 999999 SQLIRRE FEET TYF'E OF SOIL BE,_ORPTION SYSTEM] IS: MR:.'-',IMLIM NUMBER OF BEE.',ROOMS = ~$ DRRINFIELD SOIL RRTIN] (SQ FT/BR.- 85 ]'HE REQUIRED SIZE: OF THE SOIL 8B-SORPTION _.b-.TEM : [) E F'TH---- 8. 5 L E ~-.I G"r t4 = THE LENGTH DIMENSION IS THE! LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELI). THE DEPTH OF FI TRENCH OR PI IS THE DI_,¥RNL.E BETHEEN THE SURFRE:E OF THE GRO_ND RND THE: BOTTOM OF TH EXE:RVRTION (IN FEET). ]FHE TI-~-.EI'-JC;H I..-!1,1 [--:.,TH I S ,%~. (~00 FLEET. THE GRRVEL DEPTH IS THE MINiIMIJM DEPTH OF' GRR'¢EL BETWEEN THE OUTFRLL F'IPE RND THE BOTTOM OF THE EXCRVRTION (IN FEI'-:'). ~;.'E L-~.. L~ I RE:[) SEPT I ~'2'--: PERMIT RF'PLICRNT HRS THE RE_,PoN--,IBILIT~ TO INFORM THIS DEPRRTMENT DURINu THE INz, TRLLRTIuN INSPECTIONS OF- RN!¢ WELLS RDJRCENT TO THIS FRCFEFTY FIND THE NUMBER OF RESIDENCES THRT THE ~4EL. L WILL _,EkbE. TI..-IO .:: 2 .%-' I [4.'~;'PIEL~.T BR_.KFILLINt~ OF RNY SYSTEM WITHOUT FINRL IN_,PEL, TION RND RPPROVRL B~r' THIS DEF'RRTMENT WILL BE --,UBJEL. T TO F'RGSECUTION. MINIMUM DISTRNCE BETWEEN R WELL RND 8NY ON-SITE SEWRGE DISPOSRL SYSTEM IS 100 FEET FOR R PRIVRTE WELl_ OR t50 TO 200 FEET FROM R PUBLIC WELL. DEPENDING UPON THE TYPE OF PUBLIC WEI_L. MINIMUM DISTRNCE FROM R PRIVRTE WELL TO R I='RIVRTE SEWER LINE IS 25 FEET RNI) TO R COMMUNITY SEWER LINE IS 75 FEET. OTHER REQUIREMENTS MRY RPPI_Y. i SPECIFICRTIONS RND CONSTRUCTION DIBGRRMS RRE FtVRII_RBLE TO INSURE PROPER IN':.~TRk. LFITION. PEF~F1 I l' E..P ][ RES I)EE:E£"IBER I CERTIFY THRT t: IRM FRMILIRR WITH THE REQtJ'IREMENTS FOR ON--SITE SEWERS RND WELLS RS SET FORTH B~' THE MLINICIPRLITY OF RNCHORRGE. 2: I WILL INSTRLL THE S~'STF'M IN RCCORDRNCE WITH ]'HE CODES. .9.: I UNDERSTFIND THRT THE ON-SITE SEWER SYSTEM MRY REQUIRE ENLRRGEMENT IF THE RESIDENCE IS REMODELED TO INCI.UDE MORE THRN -~ BEDROOMS. S I GNED: _~_~_~~_~__~~== .......... ~ ~/~ RF'PLIC:RNT D&S UNLIMITED / DOWL ......... b ia ers 4040 "B" Slreel Anchorage, Alaska 99503 Phone (907) 278-1551 ( Telecop[er (907) 272-5742 } Izaak Walton League 6f Anchorage Chapter, IFc. Anchorage, Alaska August 17, 1982 W.O. #D12991 Area: 1 America Attn: Members of th~ Izaak Walton Board Subj: 1981 Capitol Improvements Program; Soils Log Percolation Test Gentlemen: Transmitted herein are the results of the soils investigation conducted to determine percolation ratings for the proposed Izaak Walton League septicisystem at Peters Creek. Two test pits were excavated as shown on' the soils logs Figures 1 and 2. The soils encountered between $ and 13 feet below the ground surface are classified non-frost, susceptible at Test Pit 2. The soil is a brown Sandy Gravel with less than 3 percent fines passing 0.02 mm as shown on the gralD size distribution curve, Figure 3. No water table was encountered while drilling. If you should have any question regarding this let%er, please feel free to call. Approved: Partner CRW:kf Lewis E, Dickinson Very truly yours, DOWL ENGINEERS Charles R. Wilson Geotechnical Engineer Maurice P. Oswald Kenneth B. Walch Melvin R. Nichols PERFORMED FOR: Izaak LEGAL DESCRIPTION: Lot 1, ,.UNilClPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION SOIL~ LOG - PERCOLATION TEST Walton R~creation Ar~a __DATE PERFORMED: Section i6r T15N R1W S.M. [] SOILS LOG [] PERCOLATION TEST 8/17/82 10:00 A.M. Test Pit 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19- 20- F2, Brown Gravel!ly. Silty Sand NFS, Brown SandyI Gravel, 2 to 3% silt, subrounded 2"+ gravel, 3 to/ 6" cobbles, damp, d Fl, Brown Silty Sandy Gravel, subround~d 2"+ gravel, 3 to 6" damp, dense Bohtom of Hole = 11,8' Comp. 8/1'7/82 COMMENTS SLOPE SITE PLAN W,~S GROUND WATER S E~ COUNTERED? NO - ~h P E IF~YES, AT WHAT D~PTH? Gross Net Depth to Net Reading Date Time Time Water Drop P~RCOLATION RATE (minules/inch) TEST RUN BETWEEN FT AND FI PERFORMED BY: 72-008 (6/79) Terry Barber CERTIFiEDBY: Melvin Nichols DATE: Figure 1 PERFORMED FOR: [] SOILS LOG ,~uNIcIPALITY OF ANCHORAGE DEPARTMENT OF hEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION i TEST 825 L. Street, Anchorage, Alaska 99501 264-4720 SOIL. S LOG - PERCOLATION TEST Izaak Walton Re,ration Ar_e_~ DATE PERFORMED:__8/17/82 I 10:55 A.M. LEGAL DESCRIPTION: Lot 1, Section 6._~ R]W~ 'Pest Fl, Brown Silty Sandy SLOPE SITE PLAN Pit 2 Gravel NFS, Brown Sandy Gravel, 1%o 3% silt, subrounded 2" gravel with Cobbles 3 to 10" in dia~eker, damp 6- .7 8 9 10 12 13 Mechanical Anal, NFS, Grey Gravel ,sis ~S GROUND WATER COUNTERED? .ly Sand, subrounded 2 gravel, D~PTH? damp No F1 a k La wn 14 15 16 17 18 'i 9 2O COMMENTS R~ Bottom of Hole = 12.8' Comp MeNin R. N;chols No. 4113.E Gross Net Depth to Net Reading Date Time Time Water Drop ICOLATION RATE (minutes/inch) F~ST RUN BETWEEN FT ANO , FT feet Der bedroom PERFORMED BY: Terry Barber ?moos .CERTIFIED BY: Melvin Nichols DATE: Figure 2. ±N913/~ ~B W3SW¥O3 ±N30 W~ IN913~ ~,B W3N~ IN33 ,/'