Loading...
HomeMy WebLinkAboutTAIGA LT 4ALo'T- MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241114 Work Type: SepticTank Upgrade Tax Code Number: 04103169000 Site Legal Address: TAIGA LT 4A G:2143 Site Mailing Address: 9601 MIDDEN WAY, Anchorage Owner: MAHAFFEY JAMES R & DIANNE Design Engineer: FORGE ENGINEERING This permit is for the construction of: ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date Expiration Date: Lot Size in Sq Ft Total Bedrooms: A W 1)rpartmr±rtt 6/18/2024 6/18/2025 94138 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: � ' 11-h 7\ (L- G f- Issued By: Date: Date: Z 3 ON -SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 041-031-69 Property owner(s) James Mahaffey Mailing address 9601 Midden Way, Anchorage, AK 99507 Site address 9601 Midden Way, Anchorage, AK 99507 Day phone Legal description (Sub'd., Block & Lot) Taiga Lot 4A Legal description (Township, Range & Section) Lot Size 94,138 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) ❑X Septic Tank ❑X Upgrade ❑X (w/wo ADU) Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. t (Signature of property owner or authorized agent) Permit/Rush Fees: 2 Z,5- Date of Payment: 5 j C - Receipt Number: Permit No. 2 0l M Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit App_:- : .,:c, May 30, 2024 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Taiga Lot 4A - 9601 Midden Way Septic Tank Replacement Dear On-Site Services Engineer: The owner of the above lot has a septic tank that has reached its end of useful life, so we are submitting this permit application for its replacement. The attached site plan identifies the location of the home as well as the wells and septic location. No conflicts exist between this proposed system and any other wells or septic system, whether on this lot or adjacent lots. We are replacing the septic tank with the same size designed for 3 bedrooms. The new septic tank will be a minimum of 100’ from all we lls and surface water. Please refer to the attached plan for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241114, Curtis Townsend, 06/18/24 CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FD - FLOW DIVERTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND 1"=50' TAIGA LOT 4A FEET 0 50 100Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 5/30/24 SEPTIC PLAN MI D D E N WA Y 3-BD R M H O M E 10' ROAD, DRAINAGE, SLOPE & UTILITY EASEMENT 10' ROAD, DRAINAGE, SLOPE & UTILITY EASEMENT BRACE EXISTING RET. WALL, DO NOT UNDERMINE DURING EXCAVATION EXISTING 30' ABSORPTION TRENCH TO REMAIN IN SERVICE NEW 1000-GAL SEPTIC TANK 2CO EXISTING TANK TO BE DECOMMISSIONED PER UPC Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241114, Curtis Townsend, 06/18/24 NIL ULIAIL Scale: 1 " = 30' �I I � s ' `10' ROAD, DRAINAGE, SLOPE / & UTILITY EASEMENT co U / SEE SITE DETAIL-, Lot 4A 2.16 Acres / 100' PROTECTIVE V Lot 3 456.50' o � PIPES E PIPES \ US Mi WELLS 10' ROAD, DRAINAGE, SLOPE N 77'45.46 & UTILITY EASEMENT 44j•03, Lot 3 80 0 80 160 240 / 30.0' GRAPHIC SCALE - FEET / PLOT PLAN AS BUILT X_ SCALE _ 1 80' _ GRID SW 2143 Project No J24-012 Al P.OLang & Associates, inc. Anc Box 210005 o000000 Anchorage, Alaska 99521-0005 (907) 522-6476 .o F A `��04 Professional Land Surveyors kenOlangsurvey.com o jonathanOlangsurvey.com'9S�Qo I hereby certify that I have surveyed the following described property: LOT 4A, TAIGA SUBDIVISION (Plat No. 83-65) Q tr Q Anchorage Recording District, p G g g Alaska, and that the Improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that P no improvements on the property lying adjacent thereto encroach on the surveyed o premises and that there are no roadways, transmission lines or other visible AT LAIVGAll easements on said property except as indicated hereon. OM'. yioo 7N ••.LS-9944. J Dated this the Day of M A / �MZ�', at Anchorage, Alaska 4p Fo AR ��oOFfSSI0NA0ao It is the responsibility of the owner to determine the existence of any easements, Opppo covenants, or restrictions which do not appear on the recorded subdivision plat. State of Alaska AECC963 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: _______________ Date of Issue: ____-____-____ Parcel Identification Number: ____-____-____ Legal Description Block Lot Property Owner Name & Address: Pump Installation Date: _____-_____-_____ Pump Intake Depth Below Top of Well Casing: __________ feet Pump Manufacturer’s Name: ___________________________ Pump Model: _____________________________________ Pump Size: ____________hp Pitless Adapter Burial Depth: _________ feet Pitless Adapter Manufacturer’s Name: _________________________ Pitless Adapter Installer: ____________________________ Well Disinfected Upon Completion?;;<HV No Method of Disinfection: _____________________________ Comments: Pump Installer Name: __________________________________ Company: ___________________________________________ Mailing Address: ______________________________________ City: ___________________ State: __________Zip: _________ Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. 011 421 02 TAIGA 4A MAHAFFEY JAMES R & DIANNE LIVING TRUST 9601 MIDDEN WAY ANCHORAGE, AK 99507-1231 05 05 2023 160 GOULDS 75C311-8S16 .75 13 MARTINSON PELLETS ANCHORAGE WELL & PUMP SERVICE 7640 KING STREET ANCHORAGE AK 99518 , ~ -~-.~.,VlUNICIPALITY OF ANCHORAGE ,~...., t DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 QN-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME ~ UPGRADE MAILING ADDRESS LEGAL DESCRIPTION LOCATION ~ '~ ' NO. OF B~. ROOMS ~. DISTANCE TO: ~ Well. /~ J Absemd°n area;~ O Dwelling~ ~ < ~ ~. Materiar No, of co~rtments ~ ~ Liq. capacity in gallons Inside length Width / ~ IF HOME.DE: Liquid depth ~ ~ DISTANCE TO: Well Dwelling PERMIT NO. O Z ~ Manufacturer · -- ~ Material Liquid capacity in gallons r I Well Foundation Nearest lot line PERMIT NO . ~ No, of fines ~ Length~of ~e¢¢h line ! Total ~. of lines Trench~idt~ ~ inches Distance~between fines ~ Top of tile to finish grade / Material beneath tile Total effective absorption area Length Widt~ Depth m PERMIT NO. ~--~ ~ Type of crib Crib diameter Crib depth Total effective absorption area e DISTANCE TO: Well Building foundation Nearest lot llne ~ Class Depth Driller Distance to lot line PERMIT NO. ~ DISTANCE TO; Building foundation Sewer line Septic tank Absorption area(s) OTHER ~'~/ ~J~, ~ PIPE MATERIALS T'¢F'E OF SOIL HE,..,.~[..E,I ]...f',l "" '1-- ..... ::, .:, I Eld .... 1 . TRENE::H 3:49 17'5:t 1OOO~J0 SL::!I...IF:IF~;'.E F:EIET flH,',IMJH HIJHE:ER'. OF E:E[::'RO01"T:-:; = 3: .:,L"- IL I'd-IFIN :~:; ............ '::SL::! I"'],. E,I ...... - ':':' THE REQUIRED :,I,:.E (."iF 1-HE SGIL THE: LENGTEI DIh'IENS;ION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRR:[HFIELD. 'THE [:,EF'TH OF R TRENCH OR PIT IS ]'HE DISTFINCE BETWEEN THE SURFRCE OF TFIE GROUND RND THE BOTTOH OF THE EXE:R',,,'RI'ION ':.'IN FEET>. I"HERE IS NO SE"r I.,.IIDTN FOR TRENCHES. THE GRRVEL DEPTH IS THE: HINII',ILIH DEPTH OF GRR',,,'EL BETklEEN I'HE GLITFFiLL. PIPE RND THE BCFTTOH OF 1"HE E::.-','CR',,,'RTION <IN FEET>. ' ' "- ' 1H I_ DEF:'FIRTHENT [:,L.IF.: !' NG THE F'ERf,I!T RFFL] _.-NF HFIS THE RESF'ON2.;_TBZL]:T'¢ 1"O iNFORH .... '-- ].N_ [hLLtiTZu, IN...FE_.T.[_h:, OP FINer' HELL_x, FIDJRCENT T'L3 THIS FF. LFER.~ ~ RND THE; FtUHBER OF F..E...,T. DENL. E::, THFIT TI~IE HELL I.,.IILL _ER, E. E4-tC.F..F-(LLIN~= OF RN"r' _,r_"',FEM 14ITHOUT FIHFIL IHS;F'E'CT'r:]N_ - RND [IFFY- ';'"',l-IL .... BY"' 1H" ""~::, DEPRRThlEf.,IT HILL BE .:,UE,.TEL. T TO I I..U_,EL. UTI_.N. MINIMUM DZSTRNCE BE'THEEN R NELL RND RN"r' ON-S:[TE SEI4FIGE DISF'OSFIL S'¢S"FEM IS ±00 FEET FOR R PRI'¢RTE I.'.IELL..; OR t50 TO 200 FEET F'ROF1 R PUBLIC WELL DEPEHDING UPON THE T'¢F'E OF PUBL..ZC HEL. L1. tqELL LOGS RRE REQUIRED RND HLIST BE RETURNED TO THE DEPFIRTHENT WITFIIN 20 Dl~tr'S OF TFIE [4ELL COHF'LETION. OTHER REQUIREHENT2'; HR'¢ RPPL."r'. SPECIFICRTIONS RND CONSTRLICTIOf.,! [:'IRGRRH:5 FIRE R'¢R:[LRBLE TO INSURE PROPER IHSTRL. LFCFtON. I CERTIF'¢ THRT t: t Rf'l FRMILIRR FOR-FH 8"r' THE F'ILINICIPRL. IT"r' OF RNCHORRGE. 2: I 14It_L. INSTRLL THE 2';b'STEH IN RCCORDRf-4CE WITH TIdE CODES. ]:: I UNDERSTRND THRT THE ON-SITE SEHER S?STEH HF:W REQU):RE RESI[:,Ef4bE IS REH~][:,EL.ED TO ZNCJ_U[:,E HiRE "iFIRN 2: ~:E[)ROOr,Is. FIF'PLICRNT .A[f,'I HFIHFIFFE'¢ I~;SUED E:~.__~"' ...... : ..... = ....................... [',FTE._._~.~__.~ ..... HITH THE REQUIREHENTS FOR -' ':: ' ' -" "T Llll ..IRE 2;ENERE; RND HEL. LS FIS :,E. EI"tLFIRGEHENT IF THE z:- O rfbn,~d f~r -~-.~ Date pe ed gal' Description: .~is form reports: Soils log' - Percolation test' ,pth ,,s'ground water encountered? Reading Date GroSs Time If yes, at what depth? ...... Net 'rime Depth to H20 Ne~ Drop ~r~olation rte minute, ~roposed installation: Seepage Pit' Drain Field )epth of Inle~ . Depth to bottom of pit or trench .. "ONE TEST JG WOJiTH A THOUSAND OPINIONS" 2204 CLEVELAND AVENUE e ANCHORAGE, ALASKA 99503 e 277-O231 April 4, 1978 Jim Mahaffey 5111 Shaun Circle Anchorage, Alaska RE: Percolation Test for Lot 4~ Taiga Subdivision Dear Jim, Per our phone conversation this date, a percolation test was performed on the referenced lot on November 7, 1975. A copy of that percolation test showing 85 square feet per bedroom is enclosed. If you have any questions, please call. Very truly yours, C~UCTIONC~ TEST LAB Seal tlausam~ P.E. ~ L.S. NH/ja