Loading...
HomeMy WebLinkAboutTALUS WEST BLK 1 LT 7MUNICIPALITY OF ANCHORAGE On -Site Water $ Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www,muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241173 Work Type: SepticTank Upgrade Tax Code Number: 01520130000 Site Legal Address: TALUS WEST BLK 1 LT 7 G:2736 Site Mailing Address: 4701 TALUS DR, Anchorage Owner: PETERSON SABRA A & JERROL Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: DepaFtrnc:nt 7/8/2024 7/8/2025 18725 ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day; or b. Covered, sealed, and heated to prevent freezing Received By: I J Date: Issued By: (A-.- Date: _ g � "� y 3 MUNICIPALITY OF Community Development Department Development Services Division On -Site Water & Wastewater Program ANCHORAGE PW-5fi Phone: 907-343-7904 Fax: 907-343-7997 ON -SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-201-30 Property owner(s) Sabra A & Jerrol Peterson Mailing address Site address 4701 Talus Drive Legal description (Sub'd., Block & Lot) Talus West Block 1 Lot 7 Legal description (Township, Range & Section) Lot Size 18,725 Sq. Ft. Number of Bedrooms Day phone 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ❑X Upgrade FX Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: -0 2.2.5/ 3� Date of Payment: Receipt Number: D 7 7 G7G Permit No. 05PL-111 % `5 Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit App__- : - : _.,:c Municipality of Anchorage On -site Water and Wastewater REVIEWED FOR CODE COMPLIANCE Pannone Engineering Services LLc OSP241173,CutisTamk%y ,,071W, Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panenaak.com Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, Alaska Subject: Talus West Block 1 Lot 7 Septic System Upgrade Permit Request This is a design narrative for a permit to install a 1500-gallon Advantex FAP 2.0 septic tank to replace an existing 2000-gallon steel septic tank and up -flow filter to be issued for this property. The existing tank is 27 years old and was recently found to be perforated and leaking. During high groundwater season the tank was found to be filling up & causing frequent backups into the residence being served by this tank. The existing drain field per the systems installer —was found to be dry and not contributing to the frequent backups being experienced. The existing tank will be decommissioned per code. Currently the lot is developed. The proposed replacement will be connected to the existing drain fields. This lot and the surrounding lots are served by private wells. There are currently no wells within 100' of this upgrade. 1. Upgrade Tank Design. A foundation clean out installed if needed. The tank will be located: 5'+ from any property line. 5'+ from any deck/stair support. 10'+ from building foundation. 10'+ from any water line. 100'+ from any surface water. 100'+ from any private wells. 200'+ from any public wells. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions or concerns, please contact me at (907) 745-8200. Sincerely, IsT;?__T> Steven R. Pannone, P.E., F. ASCE Owner/Civil Engineer 21 June 2024 Mailing: P.O. Box 107 Palrne;, Ai<JO5 Telep'none: (901) '745-8200 FAX: {00✓) 7_45-820_t MWOMA XXXXXXdSO 'ON 11M83d oc-Loz-9Lo ON '0'I'd 31d0S ON 31YOS tz0z/0Z/90 1-1 SNOISIA38 91566 Ad `30` KHONb 3AIK Smvi IOLti :311S NOS�J313d �O�Jd f ?R `d VdJOVS :213NMO L im l >IO038 1S3M sm vi LOZ9-94L (L06) XVJ 00Z9-94L (L06) 3NOHd (880L 1 D) 311 OASL9N33NONNVd I on I NMVHO 1 uogonj}suoo jo; df Z 7 N x W U a Q� QW9>¢> �O Z" w Zp00 ¢O ¢ ON Z Z Jm a O� OxU ¢IS- OFIn ;w 0 aK� Wwjs� aria ZZ O> <p¢ ¢ a mU KjW14O 2m 00 Z N N Z N w w wa > " Z Z Z z" W U x. O" W N— SO W S - z J < J m H N w Z x w 0 wa"O Wwz-2 (925 !L= 7J �7 NNzomG =wz mw N<Z�o �oVo ow w .:¢U1-Ir 2 ww 00 JNQ>Z ALL' Wn0 �ww�� m oa =N=w"� 4w,00 =tnIzu H wIn OU <Ngo a3< I.- Zdo Mo-<"xz mwz Z K " W Z o w w x I >LL" O Z w Z p¢ W j<w<!L"Q LLIU--N 0� �wWN301 #<= aa� W 3 N N w x Z S U. Z Q w A Z W w a d J Y U w w w 2 VI 0UV"K- ZKU ZN ow a az O m U"O = W Oa W N O N S O 0 az W 9 , K Z o a Z Z a O U w-W K. O w w LL0 J p< w z w p x O Q Q Q 7 w W a NNWZ"¢LLOW WO WU Xo KZaW"Z QZa "(S9 n. �Na�nmvm3w,-59A "OZ o>" J W g �' �¢. j3_3ro-1Daowcaiaj zNVO-ir"zao¢w o❑z,m J Zx ffiRNUX-OwIZW 7 J w 7 HOO V)O .rjmpJ N6 Nam �2ZNO00- Jww �Mm " O- QQ¢.m NON K J= K¢ a O K W K W K Z O Z< d. x ¢ Z"> O< O OSOOY 03ri r+-ZO�w os0 85Z cUoJc"iOI U Quo=UDOM¢�U�< moZ ww 0wO �Nflazwg=gg3"�p�o-990aiI pao �z oop�mJZwo�oo�wmoxm�o?w�j zam ¢ w(aJ�w�o(,9wSwwQ1-waw (Zw m o2-� FUQ x0.-�xw2wx"x21-02 wrV1w2U7 U"7" a� "Ja"31ntr"or"Inz"°d zaaJ"z" xmZ Ia., _ 1 U 5io< N M V iA IO I� t0 a O Q �T < < sF •1' < a v y ¢ Q = W ZO> m NZ O W w W U In 0 1 m ZOaaOp <1 ON OOz " p 3 0 w a o in V= U 2 7 lL < O < z O W a' Q Q l- > 0 W O w N w w z W VI ¢ 4 a 2 LL t O ¢ = U mZ�-=zwrw¢ 2 O_w'' J �j aw " n " i+-�- " w SL w#O r= mx x 0 4. a w0"of_r WwU� Na 0In = a¢ ¢w o o ¢ m w NJ x w�w0 ~ W O S Om JU1¢-N_LL wzK Qom V1 VI ¢~>2 " !- w0 Z2 0 2 ZO W J U F ON J" 3 w W O QLL F¢cJ>JNWooxm<u FU LLtn¢ V m m00 "O � K per- � 2 � ZO � Ozmg ¢ Z p W 0 m z �w ozg)� 0 U ."w ZJ W¢>Q z OZU 3Z o 3 N 7 OF O- ¢ 0 N d UJ U(Pwz0=K,Q0Q Va. ypWp� OU� 0W0=Jw YJ Q Z ZO J Z O p� jZ QJ� N ZO w 2 7 2 a =li w N WQ"O�OSO ¢O �dW 7 LLW ~ UO� O O LL Q w p Jj ❑c3 CQ SZ > O H O m O J W r=\wOULL W W� ZZ 0 U'm pOO �V1 Z V10 Z �I�JJ QQ W mw Wo N< ULL v"VIW IiO}xK W Oa 2Uw 21 O WNw Z Q U Ww m O > x Za Z_ LLxm < 7 ¢ dZ O,,ZOZt wgt--O"> UW ZZ" �¢ w2KZZ�W"0 N � JF O O d g0 v'O UN4r.+ Ow¢ rn Q W H O_ "w wZ fan Jm� W� N 70 l7 FLL } m"4vW OQw t� O m" y"j U 6. < N U p d Z �O" W Z K 3 =" O K O W VIQZm QZ Z V"I OU W NO �W >� V,d a"WN O W a wm w ¢ < v0 Z7 W J 2 U O U� w " SwOW6.N v'SW 2 pW> W� �dO7K1-W� W W7 W K 7M Z ¢�"� OaO W K 6' Z~ J oZm�"WZWNO,O ¢a S2 S O <JxN wZw0ag4a N 7 NN V w OQN EQ NX- ZWVI m w U aVl LL UV1 Fn!j apx..K<r=W 3 w.•� =021W--~Q p0. Opp' ¢ w mm LL N Z of EV m7w a4x O O IL Z az U WZW< Vl"K 00 1-� VW sI'- < J��WWQ* 2 j UWWU NO U� Wzi_ 7 W co00 OO�wNN " w QN Q m000K O "x"1- U 0> �' w WZ> om �UOQ O3 m Q W, F-NW� w--U Wa' O �3NI. w�''iw0 w1-�U"aZ0 U I > F- M22O �M W OOY J " W2HOZD ZY-wW dl�. OON!- iZ pJ7 6.01- Z � O Q � U " d U U z �• UO 0 Sm"ZZUwLL3Z " zv Qru �_OJ _.w SmmU o �w,IZ J 3 O¢a17 Iw ZpOa �w< z <V13O W Q W WW K W" W W Wa 3 Z2LL 2" ¢ wD QZ3 Ox aJ._. ¢ wNmvl 0"U LLO ¢ w a¢ C! Q z �j Q z 0 3 Q x w z o 2 K:" w W Q S ey Z > O Z o U O Q O 0 0 3 0 o N O K " w > > W �N�nnQ O 01 w O QQm r 2" N 7N� wOj.. J W I Z t� LL W Y7 O �WKI- N �W yNj7 Z W m 0 O Q Cil aN J (1. 36�W��pWNN ¢LL 2ZStnNw=m mWJO"00� O " r W2 OLL Oo. VI 20�'j ¢ Q 2 d' 2 U -a O OI- Z V1000 U mwa N ONWIn O Op gZ3 o v"owN� Jw V owaI"w¢�" 3 G a,--o-V o =N oQ zo n O N mZ w> mazy I LLJ o v U I- Z z yyJV)z <m z�ZOlt ��OUKWW az Z � Wwwp, 0" �� Y U 1- J � < 7 Z ^N ONpW W,z O N N m< RND " z �pQ QI"/11=NZWIW-Ur wO HOwVIS-m VIO �ZOOr MU Z GLL 7 ZOW0 NLL w�wN OU w W x v"rz °'oo:E. SVaa z3mw�az �o z"c�Z a�Wa w o U-xo 20 o tr 74 w a 0 O W �i W W Z w W 0 w < O ti o J 3 m m U N W W W_ K y nv 0 w " 2 x K z o o w?�C,wW3o n m UW wmwV z o4I.L )w0., QwQ>mapw m x � o oWo� �Os Zzw "zo V) x 2 jW...FI�ZYZ J �QwZWrd"yw10 z a Ny-¢rI�.QO w>USww.-1 O m l!z w J IZ�O N�7 pi�w w9m z m v OmY7ZLLU0 w a� xQ�d who pw �InpO a" z S>Xw" o� oQ- =aoz o"= < of > g < N W ZO-v0m N 70mZh0 w"3: Z wm OZ�V03pZ I-¢W ¢gw < JJOw m'ro I 2J EC pgU a LL>a�p�O�p > ��=�wmowfaw>o "na¢""z5a >Ww�a�J mo'�ozozaoo^o sW6o=w zo w O O VI U< O Z z< w a~ yOy V 2 W J~ a U d ow U O W Q Z OW W w a" m Z O Z m W Zp m Q N OW D Y W w" p Y< J -1 W Q aUQ J Q" N O w 2 3E 3 UWz =VQf11OF K Z0yS1-awtr3�LL� N� LLNN�2wQ��� NO00¢ZNG E-ONZ a >7Y¢�S ` FnxmUZ�o aad U � z"O�"ww7 w wz0z<z�owozo a2 p�nw zaUlna -or-. `tw¢ ovoz_>j� a OUzTUwN oc93omszLL wWIn QZ1Z 1 x z O Jr2- O¢ 3O000ZZ W W "K Q i O¢ Z=Q OmWOWr2- UX Jpa,J-MU I, am<Y z W <Jp z0 W Wo 515 .0 Z J-zWZ m~ l.¢U.Qrnuz<--,- QQpOQO�W �Q w O. 9 ff W - NNJQ �Q_,a aZNOOJ Z O W V) Z LL J^ O W pLLJU OU I-OJ Z In " O" 0 O O O O O 0 U O U ¢ mw� O" w K 3 W U > J S U 3 U Q W x Z J W< U w Y 0 S w Nl W W Q w K m W >> 0 Z O " Q a p m J Q Z WW xO-VI UWT• O QQ aa" WWZ t- W 3 NW__ Ir N mJ(L VIJ 1_ Ja 0 ZJ 4yzj4 U"�=Q"OW wp, _LL<OWOZU=NO2 Nj` R�¢�O p0 " FLLW wW OIyy` V1Z wH= Q Qa J•WIUU 7ZO7JwZ" V'0L. H �h- 7K «W"ZZ2 w7S d'+y W!-2 V - w N¢ ZZ4i3W} W<zow,KJ OZN" VY1N3aJ0K2 1==mZWa03 x¢O Vl d' a W- O r- O m 6 W_ -z 4 7 V1 "- Z N " K umx Q ww0 0_ 70 Z p'T'O {nOJUm ZNU K z 2mx Z O O ""� WiJJw- .a.. "N �Z2 U QJW_ LL OM,-S -w-,jm " WOLL2 ma--W< Z g z�z N�a w<Z..,w �wwmNwWc>.I ¢w gZ �w Y3xmao "o�''JwMa I"Dww az oN"�c�ywa�OQImm zma¢o " WIW zWwFLLU"OZO S20 xwZU U Va N�pt-�G' " WW ZU LLQ�i N-JCY7 > U�N2� �V VIZ V) W W ¢ m m O"VI70�V1� Q S "\ Z"OW ZY¢ 70 n NJ01'Vl �y 6. O¢W&Imw K;. Mo Kao 'O 00, W_O_3 0-Q�Q_w�1- LNaO �. JwJZWWOZ�azmOQU ZQIn ¢O0 QUQp> KUJ ,rioa''j Q�W OJ >4~= NNCwxJW OK Woi "¢OUW�g7WUN-J�Q xN7w QJh ¢J¢ O_ 06'!)'-S wWWO I`230 In U^ U LL > Q OZ=OI-N ICL I...U� ZJKZ UW7ixd7 aZ O m= 3 x" m to a k wI- w 7 a f.9 ^ W0. `t h 7 O w O " p Q¢ U Q W Z W O O T 7 0 U W H z O W" J Q. Q J m O LL z N uouz-" J< " p0 0 Z W rmaNwNwa3��ma ozip WH��Y V)Z SZH7 U76a. <m<ma7NZ7 WZQm�+p, CQWQ1WwaJaOgpwNW�N�mFW-Ki �OW�.zWUO"OW Z o w¢ W N 2} = 0 0= m 7 Z LL W J W a O K 2 S�� J Z X 1- x 0 J Q W J a O Z O O Y Si- J N Ow z 2 O w~ OJ O O W Z X O ¢aa3az "Inw"3U3ow< m am¢ of U`-rina awwaIwa JCL WQU00 3-,<zca 1U ,Um�N�x`C¢�WU tV M a N �G tV r) a ul N ri ri ri Mi �i riL v_ _ a ai of o c�i ri v ai tV tV IV IV N es!NI < N M < In MD r� m T ri h 7 N N N N r7 M t•') IM T Nj M T T T T M 0 T n Z 30 t 133HS •zoa/t=su• p u 6 t9 3 Q •, ••K ..• d0� 91566 AV `30V<IJOHONd RE 3nIdG Smdl IOLt :311S NOS�1313d �O�I�J3f �8 t1 d2�8dS �i3NM0 L im l >i00i8 1S3M smvi Qn-site water and wastewater MEM)k U _ xxxxxxdso 'ON 1IV483d — --- 02-toZ-slo•• ON 'al'd VIP �i T�07 oil NMV80 31vOS vZOZ/OZ/90 31VO LOZ9-G4L L06 XVd OOZ9-9tL L06 3NOHd St+96p NV '?l3plVd L091 X08 'O'd �990b TO 3-1-1 OAS ON3 3NONNVd uoiton�tsuoojo� sNOISIn3a a ' AO V�j I wQ UJw0 z �ws3 _6uJ0 -7'n. �n 01 Y o n o N 3 w z , W — ro ~ wNLQ 0 0 — /—� Cl sZ aUWo _, — > J wZ Qi=in_j 2 W mzwa �3� �a0Z 2 wz OL M A-� wz <nw,w-w pa pwd 0 / Li pp Q�00 C O N Li W n O 0 Q m Z) zv~ar ao 0 m w �Op r 0~ owZ- h z ooza Y \ / 03z0� z� oQ } \ to Y �8M �w�wm • O J ¢Kz w d' J • ` 3 / 3 z=O w tai yIL 0� w Om dQ owo>- 0 Z Nm z 3 Oa QaWQJ OZQYN /wp8w 4. w- ��w m005zZ wwU,vViQ / 3 tn�OL-, ¢MQwN / IL)L) o aOOzz O / -iW z Z0 Z �p ZNmm 20 z<Oww� LiZ 0 0 >OO 4ZQM< . W `\ � �~ z Q 3�=z�N a�-mW C � W 0j~Qom Q< JOU) v S M i Q v U p w wOmz aCQ 0NW0UOZ J aO� p a w aw Ozr z V 3 0woz Qco 0� , 20� wa W r�O]�ZwZV) -i10Z O U- � �U�UZ�K�HQ LLJ 1: QLwK 2aN pQQ:<z, 'iwZLjwQ L,Ln (LZ MOmLZZ ) LLJ )LL zOp w dw O�QN oCE LZzm>mao JF5>w=F(Lnw, Ow W.�<nV1F I-VI1=-•-NM Kd ddQ3O vl Q O tW.4. ��Oqk Z� Ln J �sF� OW OW 2 gln�roQ �C~ moo L Z � � i I O U O O�° W~°�Q cn O� i Qoa�2~o�iWooe � m� Q) ( O 1I ` S jl O `V I I m `, O o� � i ~ Municipality of Anchorage Page , --' DEPARTMENT OF HEALTH AND HUMAN SERVICES ~ ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On,Site Wastewater DiSposal System and/or Well Inspection RepOrt. ' Address: 4~O[ T~Ug ~lv~ ~lg ABSORpTION.FIELD'~;~{~??~r.. Phone: NO. of B rooms: ~ Deep Trench ~ Shallow Trench ~Bed" LEGAL DESCRIPTION so,.,...: Toter Dept h ~rom od~ln~mde: Subdiv~[on: Depth to pipe boffom from original grade: Gravel depth beneath plp~. ~ ,D New ~ Upgrad~ Gravelwidth: , Numberofline.: Ola~ification (Priv~ Total Dept · ~ased To: Ft. ~ ~ SQ. Ft. Pipe mMeriah ; . Yield: IPump Set at: IOasing ~d: TANK TO Septic Absorption Lift Holding ~P¢ivat{ Manufacturer: Capacl~ in gallons: From Tank Field Stat[on Tank Sewer Lines ~, ~ ~ ' Surface log% too'~ IOO% / LIFT STATION' Water J gO ~ Line / "Pump on" level at: "Pump off" level at: CunainDrain . U~ ~ 0 ~ U ¢~ ~ Pumpo~ooMake & Model Electrical Inspections~_ o.Ped°rmedA by: . Remarks: ~ wA~v~ ~ ~&97oo37 BENCH MARK _ ... ';_ - Depadment of Health and Human Se~ices approval '~%~t"~,. . '- ."%~%~ ' Reviewed and approved by: ate: ~ ~-- · ' S~/'970195 PID~ 015-801-30 AS-BOIL T DVG, aO00 GALLON STEP TANK WITH REClRCULATING TRICKLIN6 FILTER, UPFLD~/ FILTER PER ANCH, TANK NE~/ BED 10' x SAMPLE PORT 4 INCH PVC~ 'H' A# HOUSE C/D 'J SHOP INC AE = 29,2 CJ = BE = 33,7 ]Od = 20,4 AF = 37,2 CK = 19,3 BF = 28,4 ]OK = 14.5 CH = 14 CL = 18,9 DH = 84.6 BL = 16,5 CI = 11.3 CM = 81.8 ]OI = 20.a ]OM = 19.2 CG = 15,4 DG = 30,5 ]XISTING ~/ELL SEPTIC UPGRA]OE AS-BUILT, LOT 7, BK 1, TALUS WEST S/lo, PREPARED FOR: ~/AYNE 8, MANNA JONES PREPARED BY' DATE, 8/11/97 ALASKA ~/ATER & ~/ASTE~/ATER [ DRA~/N~ GARNESS l SCALE, 1'= · ' OVER FILTER = 2 + , ~ OF I)RAINRDCK OVER THE TOP (MIN,) SAMPLIN6 PORT OUTFALL TD BED, INV. = 98,~5 DRAINROCK% ~ ~~ 2 INCHES DF ~LUEBOARD, ~ TD BE~ INVERT ELEV, 98,1 NE~ STEP TANK WITH RECIRCULATING 4 INCH ~IA, PVC LINE FRDM / / SEPTIC UPGRADE ASB-BUILT D~G~ LBT 7, BK 1~ TALUS WEST S/D, , ALASKA ~ATER ~ ~AgTE~ATER ]]ATE, 8/1]/97 DVN, GARNESS SCALE: NTS 3kl[al6]kal Wa cer & 11471 Brookridge Drive ~ Anchorage ~ Alaska 99504 Phone (907) 337-6179 ~ Fax (907) 338-3246 Consulting Engineers July 28, 1997 Dynamic Properties 3111 C Street Anchorage, Alaska 99503 ~" Attn: Janet Daley Subject: Well Test at 4701 Talus Drive. Lot 7, Bk 1, Talus West S/D. Dear Janet: Per your request I performed an adequacy test on the subject well. Prior to starting the test, the liquid level was 84 feet below the top of the casing (BTC). Water was pumped from the well at an average rate of 6.83 gallons per minute for 66 minutes (451 gallons). During the first 10 nfinutes of pumping, the level in the casing dropped 8 feet, down to 92 feet BTC, and remained at that level throughout the rest of the test. In short, it was recovering as fast as the water was being pumped out (6.8 gallons per minute). Based upon this data, it can be concluded that the well produces greater than 450 gallons per day, as required (by the Municipality of Anchorage) for a 3 bedroom house. Ifyou~aave any questions, please contact me at 337-6179, or on my digital pager at 1-800-481-1162. ,// Sincerely, Jeff, ~ ~.[{}~ ness, P.E., M.S. Prin~ ip~d [/ [ 0/t PAGE 1 OF MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUFn~N SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PER~IT PERMIT NUMBER:SW970195 DESIGN ENGINEER:ALASKA WATER & WASTEWATER SERVICES OWNER NAME:JONES WAYNE H & VANESSA K OWNER ADDRESS:4701 TALUS DR ANCHORAGE, AK 99516 DATE ISSUED: 7/17/97 EXPIRATION DATE: 7/17/98 PARCEL ID:01520130 LEGAL DESCRIPTION: TALUS WEST BLK 1 LT 7 LOT SIZE: 18725 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AMD THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AMD CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: THE PROPERTY OWNER SHALL BE RESPONSIBLE FOR MAINTENENCE OF THIS SYSTEM PER AMC 15.65 ALTERNATIVE SYSTEMS SECTION INCLUDING THE ' . ENGINEERS FEE FOR 9NCE A MONTH EFFLUENT SAMPLES. RECEIVED BY: DATE: Rick Mystrom, Mayor c p hty of Anchorage Department of Health and Human Services 825 "L" Street P.O, Box 196650 Anchorage, Alaska 99519-6650 J~ly 18, 1997 Jeff Garness, P.E. Alaska Water & Wastewater 8471 Brookridge Drive Anchorage, Alaska 99504 Subject: Waiver Request for Lot 7 Block 1 Talus West Subdivision Waiver Request #WR970037, > PID #015-201-30 Your request for a waiver of the required 10 foot separation between an on-site wastewater disposal system and a lot line has been approved. The waived distance is 5 feet from the leachfield to the east and north property lines. This approval applies to the existing on-site wastewater disposal system lot line separation only. Any future upgrade to the on-site wastewater disposal system will require all separations be met or another approval from this department. If there any further questions or concerns regarding this waiver, please call our office at 343-4744. ,.~erely, ~rogram ~ana§er MUNICIPALITY OF ANCHORAG~~/ Department of Health and Human Services On-site Services Section Waiver Review Worksheet WR~ WR970037 PID# 015-201-30 HA# Permit Date Received: July 8~ 1997 Legal Description: Lot 7 Block I Talus West Subdivision Engineer: Jeff Garness, P.E., Alaska Water & Wastewater 8471 Brookridge Drive, Anchorage, Alaska 99504 Applicant: Wavne& Vanna Jones Waiver Requested: Lot line waiver of 5 feet from the iea~hfield to the east and north property lines Criteria: 1. Geology: Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation TOTAL: Special Conditions: 3. Other: Waiver is Granted: ~ List Conditions or Reasons Waiver is NOT Granted: for above: Date: By: Nam~ of Reviewer Rec #: #02794/0741 Amount: $ 115.00 Date Paid: July 8, 1997 PROPERTY OWNER AGREEMENT FOR THE MAINTENANCE OF AN ON-SITE WASTEWATER DISPOSAL SYSTEM This agreement, dated ~-t4 g_/ / ~z 19922_, is made between the Municipality of Anchorage Department of Health and Human Services (DHHS I and the property owner(s) of:. -- oe -7- /7 This agreement is made for the purpose of maintaining an on~s~te wastewater disposal system on the subject property. The property owners agree to the following: Allow the Municipality of Anchorage the perpetual right of entry to the property during normal working hours, to allow for effluent sampling or evaluating the general state of repair or function of the system. Submit to the Municipality of Anchorage, on an annual basis, an inspection and operation statement from a registered professional engineer. This inspection and operation statement shall verify that the engineer has inspected all effluent and air pumps, timers, and alarms, and that any deficiencies have been repaired and that the system is functioning as designed. (Sign t~ure) (Signature) (Printed Name) ~ - I k -~N6~tarize Here) (Printed Name) Rick Mystrom, Mayor Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 http://www.ci,anchorage.ak,us Dear Homeowner/Prospective Buyer: The on-site wastewater disposal system you are purchasing/installing is an "alternative" ~/vastcwater disposal system. This system, known as a "ReeirculatingfUpflow Filter Septic System", is undergoing testing within the Municipality of Anchorage under the Alternative System section of the Wastewater Disposal Regulations (AMC 15.65). There are certain risks involved with the ownership of one of these systems: The technology used in this system has been shown to be effective in other areas. The system is currently undergoing a two year testing period in Anchorage under the guidance of the Department of Health and Human Services (DHHS) and the State of Alaska Department of Enviroumental Conservation (ADEC) to determine its effectiveness in a subarctic environment. Thc system for this property may have received vertical separation distance waivers from both State of Alaska and Anchorage Municipal Codes to both ground water and bedrock. These waivers were granted due to the system's expected performance within the site conditions on this property. If the test results do not support these waivers; modification or replacement of this system may be required. If this system fails to meet the requirements set for it to become a standard, code approved wastewater disposal system, it may have to be removed and replaced by either a holding tank or (if possible) other wastewater disposal system that meets Municipality of Anchorage requirements. The cost of any conversions required to meet code requirements will be the responsibility of the homeowner at the time of conversion. I (we) certify that I (we) have read the above statements and am (are) aware of the risks outlined. I (we) also certify that I (we) am (are) in the process of purchasing (property legal description): (Purchaser N~) (Purchaser Signature) (Purchaser Name) (Purchaser Signature) Notarize Here 8471 Brookridge Drive ~ Anchorage ~ Alaska 99504 Phone (907} 337-6179 ~ Fax (907) 338-3246 Consulting Engineers July 3, 1997 Municipality of Anchorage Department of Health & Human Services Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref~ Septic System Upgrade for Lot 7 Bk 1, Talus West S/D. RECIRCULATING UPFLOW FILTER (RUF) SYSTEM To whom it may concern: 1. GENERAL: The existing 3 bedroom house is currently served by a private well and septic system. The existing drainfield will not pass an adequacy test at this time, therefore, an upgrade must be performed prior to the sale of the house. Given the location of the structures, the old trench, and the protective well radius', the area available for the new drainfield is very limited. Because of the space constraints, and the soil/groundwater conditions, we are proposing to install a Recirculating Upflow Filter (RUF) system, designed by Orenco Systems, Inc., and marketed by Anchorage Tank. The drainfield will be located in the northeast comer of the lot, within the 30 foot radius cfa test hole done by Construction Engineers in 1980. Although the specific location of the test hole was not shown on the soils log, according to the homeowner, the monitoring tube pipe used to be visible, and was located at the spot shown on the 30 scale drawing for this design. At a depth of 4.0' to 4.5'to soils perked at 35 minutes per inch. A groundwater monitoring tube was installed (see location on 30 scale site.plan) Dy Discovery Drilling on 6/25/97. On 7/2/97 groundwater was 8.7 feet below the surface. Also shown on the 30 scale drawing is a test hole on Lot 6, Bk 1, Talus West. Per the soils log, groundwater was encountered 3.1 feet below the surface on 9/29/89. This test hole is only about 20 feet from the proposed drainfield for the RUF system. Based upon this information we are proposing to install the new drainfield at a maximum depth of 1 foot below the existing grade. This should provide a 2 foot separation to groundwater. It ispossible that the water level may rise high enough m the future to encroach upon the septic system; however, the extent to which this' may occur is' difficult, if not impossible to predict. The specifics regarding the design are sununarized as follows: 2. DRAINFIELD: The intent is to install a Recirculating Upflow Filter (RUF) system that will allow the use cfa small drainfield in the area of the TH. The size of the drainfield will be based upon the previously established criteria for the RUF systems, which dictates that soils percolating between 30 & 60 minutes per inch have an allowable application rate of 2 gpd/fi2. Given this application rate, the system (3 bedroom house, 450 gpd) will require a drainfield area of 225 fi2. This corresponds to a 10 foot wide field that is 22.5 feet long. 3. ORENCO PACKAGE SYSTEM: Attached is drawings of the Recireulating Lift Station Septic Tank with Trickling Filter, prepared by Anchorage Tank. Per Lowell McNutt, the system is designed to handle flows up to 750 gallons per day. The entire package, except for the wood, and the sand is provided by Anchorage Tank. Since you are familiar with the operation of the system I won't elaborate. As with their standard STEP tank, it is equipped with a high water alarm per M.O.A requirements. 4. SURFACE WATER: There are no surface waters within 100 feet of the proposed septic system upgrades. 5. TOPOGRAPHY: The lot generally flat, with a slight downhill slope from east to west and from north to south. The slopes are less than 5% In short, there are no slope concerns. 6. SUBSURFACE I)RAIN: There is a fou~adation drain that runs along the east and north walls of the house, and flows to a sump that is equipped vAth a d:~z=hargc pump. The new drainfield will he approximately 25 feet away from the drain. Given this separation distance, and the effluent quality going into the drainfield, it is highly unlikely that any untreated wastewater will reach the drain. 7. LOT LINE WAIVER: Do to the limited space constraints, it will be necessary to place the drainfield approximately 5 feet from the east and north property lines. The closest adjacent septic system is located to the east on Lot 6, Bk 1 (about 15 feet away from the lot line), which will be about 20 feet away from the new drainfield. We are requesting that you waive the required separation distance to the property line from 10 feet, to 5 feet. The limited space dictated that the side slopes of the field (slightly mounded) be limited to a 2:1 slope (26 degrees), so that they won't encroach on the neighboring lots. Obviously, the north side slope of the drainfield will be in the utility easement. The waiver fee of $115.00 was submitted with the design package. 8. CLOSING: Clearly, this property has numerous site restrictions which limit the potential for septic system upgrades. The suitability of this design will be limited by the soil/groundwater conditions at the proposed bed site. In the future, it may be necessary to move the shop building, and use the area for additional drainfield. Time will tell whether this will be required. I am open to any suggestions from your department that would be an improvement to the proposed system. I am unaware of any negative impacts that this installation would impose on adjacejat wells, or septic systems. If you have any questions, please call me a 33%6179, 244-9612, or on my digital MUNIcIPALITy OF A NCHOg. AGE ~'NVIRoNMENTA~ SERVICes DIVISIO~ ECEIVED m~ELL ALP~ CIRCLE LOTS 4 & S/3, EACH WELL TALUR ~RIVE SEPTIC UPGRA3E: PREPARED FOR: PREPARED 3Y~ DATE~ 7/3/97 LOT 7, ]3K 1, TALUS 'w'EST ',dAYNE AND VANNA JONES ALASKA ~/ATER & ~/ASTE'w'ATER I DRA~/N~ GARNESS ISCALE: 1' = 100' / 1,25 INCH Y LINE TD UPFLOW EXISTING HOUSE 4 INCH PVC TD NEW INSTALL FOUNDATION H20 MONITORING TUBE ENG, TH DONE BY CONSTRUCTION ND GROUNDWATER TO 16 FEET; MIN/INCH FROM 4.0 TO 4,5 FEET, IN 3, 9/29189 EXISTING WELL WELL SEPTIC UPGRADE~ L[3T 7, BK 1~ TALUS WEST PREPARED FDR~ PREPARED BY~ DATE~ 7/3/97 WAYNE AND VANNA JDNES ALASKA WATER & WASTEWATER SERVICES DRAWN: GARNESS SCALE: ]' = 30' SEPTIC UPGRADE: LOT 7~ BK 1~ TALUS WEST S/D. DATE~ 713/97 3WN~ GARNESS SCALE~ NT2 NOTE: THE DESIGN OF THE RECIRCULATING TANK AND THE UPFLOW FILTER MAY BE HODIFIED BY ANCHORAGE TANK TO MEET LATEST DESIGN REVISIONS BY ORENEO INCH PVC TO SAMPLING PORT. WATER TIGHT BOOT AT BOX LINER PROVIDED WITH THE DRENCD KIT. INCH LAYER DF WASHED 3/O INCH PEA 6RAVEL. PLADE ~ INCH PV£ LINE AT MID DEPTH, OVER TOP DF UPFLDW FILTER. MIN, COVER = 2 FEET 2,3 FDDT THICK SAND LAYER, ANCHDRAOE SAND PEA". 12' LAYER DF VASHED 3/8' PEA GRAVEL R INCHES DF INSULATION BOARD DN BOTTOM AND ALL SIDES DF THE UPFLDW FILTER DBX. PROVIDE 4 INCHES DF INSULATION OVER THE TOP DF THE BOX, PLACE FILTER FABRIE OVER THE TOP DF THE DDX PRIOR TD BACKFILLING, UPFLOW FILTER BOX IS LINED VITH LINER PROVIDED WITH DRENCD UPFLOW FILTER PACKAGE, NE~ STEP TANK WITH REGIRCULATING FILTER, PER ANCHORAGE TANK DESIGN. i.~5 INCH PRESSURE LINE TD UPFLDW FILTER INCH DIA. PVC LINE FROM DUSE, ISEPTIC UPGRADE~ LOT 7, BK 1, TALUS WEST S/D, PREPARED FDR~ WAYNE & VANNA JONES ALASKA ~ATER & WASTEWATER DATE: 7/3/97 OWN, GARNESS SCALE, NTS A. Garness ; CE~7953 ~-~ MUNICIPALITY OF ANCHORAGE ~.~¢/ DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-47;20 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME MAILING AD~RES8 LEGAL DESORIPTION LOCATION Manufacture~[~ ~. i~- Liq. capacity in gallons IF HOMEMADE: Inside length Dwelling Mat~.~.~ ( W dth ~ PHONE -[~NEW ~j~O~-/~='~ [~]UPGRADE No, o~compartments Liquid dep~th DISTANCE PERMIT NO, Well Foundation Nearest lot Kine DISTANCE TO: / ~- ¢ No. of lines Length Total length of lines I Trench width Top of tile to finish grade Material beneath PERMIT NO. 0,_. ?s°xt~nDea Length Width Depth PERMIT NO. C/ell foundation DISTANCE TO: Depth Driller Distance to lot line Building foundation Sewer line Septic tank DISTANCE TO: OTHER PIPE MATERIALS SOl L TEST RATING REMARKS PERMIT NO. Absorption area(s) LEGAL 72-013 (Re~. 3/78) P~..~Box 4-1224 · 1310C International Airport~_~./ad (907) 274-46] ! ANCHORAGE, ALASKA 99509 DRILLING LOG , Well Owner_--D~ nk ~.lr~ ghi- U~e of WeD ~0 Location (address of: Township, Range, Section, if known; or distance main road TL. ot ?, 137 ' feet Cased to 136' feet (below) land surface. Finish of well (check one) ). open end ( X ); (minute) for tPk~ hours with /O/~ ~ ft. Size of casing~ Depth of Hole Static water level 4~0 ft. (k~) Screen ( ); Perforated ( Describe screen or perforation Well pumping test at~0 gallons per of drawdown from static level. Date of completion- 11 - 7- ~ ',' WELL LOG Depth in feet from ~;" · ~- "; .' ground surface Give details of formations penetrated, size of material, color and hardness 2 _19 22 93 TO~ TO 19--- TO_22 -- TO 61_ TO 9~-- TO. 125 TO~7 - .TO TO__ .TO .TO· __.TO .TO. TO. ,qandy T{ard Pa~ Sand Silty Hard Pan Silty Hard Pan MUNIciPALITy ,q~ £/,,Vt.~O~I. o~ RECEIVED' I -- CUSTOMER F'ERMIT NO. FIF'PL I CRNT DICK WRIGHT I'"' LORRTION TRL J=, DR. LEGRL 'LOT ? B ± TRLLIS WE_-,T SUB LOT _,I,:.E ~-1, ,_,~:.l .=,L~UHRE FEET TYPE OF SOIL RBSORPTION SYSTEM IS: TRENCH .... ~" ¢?¢ SOIL RRTING '::SQ FT,.'"BR)= 270 MRXIMUM NUMBER OF BE[.'RuuM_, = THE REQUIRE[:, SIZE OF THE SOIL RBSORPTION SYSTEM IS: [:"EF" T g--~ = i2 L E i~-.~C4 T H= ~ G R !-~'.~' E L DEPTH= 8 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD. THE DEPTH OF R TRENCH OR PIT IS THE DISTRNCE BETWEEN THE SURFACE OF THE GROUND RND THE BOTTOM OF THE EXCBVRTION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRRVEL DEPTH IS THE MINIMUM DEPTH OF GRRVEL BETWEEN TNE OUTFRLL PIPE RND THE BOTTOM OF THE E,~4CR',,,'RTION ,::IN FEET). } PERMIT RPPLICRNT HR-~ THE RE_.PON_.IBILIT~ TO INFORM THIS DEPRRTMENT DURING THE INSTRLLRTION INz. PEL. TIoN_. OF RNY WELLS RDJRCENT TO THI-~, PRUPERT, RND THE NUME, ER OF RE_I[.EN..E_ THRT THE WELL WILL -,ER,,E. TI,,4L--~ .:: 2 .":. I ~'-.~SPEL-:T I C~i'-,IS F~RE RE -['-.~LI I F-." E [:. BRr:KFILLING i-iF RN'T' _,~-_,TEM WITHOUT FINAL INSFECTION RN[:, RFFR_ /RL B'-? THIS DEF'~RTMENT WILL BE _,U6JECT TO PR3--,ECUTION MINIMUM DISTRNCE BETWEEN R WELL AND RNY ON-SITE SEWRGE DISPOSRL SYSTEM IS 100 FEET FOR R PRIVRTE WELL OR i50 TO 200 FEET FROM R PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL MINIMUM DISTRNCE FROM R PRIVRTE HELL TO R PRIVRTE SEWER LINE IS 25 FEET RND TO R COMMUNITY SEWER LINE IS 75 FEET. WELL LOGS PRE REQUIRED RND MUST BE RETURNED TO THE DEPRRTMENT WITHIN ~0 DRYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MRY RPPLY. SPECIFICRTIONS RND CONSTRUCTION DIRGRRMS PRE RVRILRBLE TO INSURE PROPER INSTRLLRTION. F'ERi"'I I: T E::-::F" I RES [:,EC:E~'-IE:ER '~-':::L.. 1'--:~8 E~ I CERTIFY THRT 1: I RM FRMILIRR HITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS RS SET FORTH BY THE MUNICIPRLITY OF RNCHORRGE, 2: I WILL INSTRLL THE SYSTEM IN RCCORDRNCE WITH THE CODES. ~: I UNDERSTRND THRT THE ON-SITE SEWER SYSTEM MRY REQUIRE ENLRRGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THRN } BEDROOMS. _- . SIGNED: ............... RPPD.I.CFINT D I C:K I,.IRIfC_.JHT MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L, Street, Anchorage, Alaska 99501 2644720 SOILS LOG - PERCOLATION TEST PERFORMED FOR: ~ i ~. ~ LEGAL DESCRIPTION: ~"~ DATE PERFORMED: ~ SOILS LOG [] PERCOLATION TEST 5 6 7 8 9 10 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- COMMENTS PERFORMED BY: WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? SLOPE ~0 SITE PLAN Gross Net Depth to Net Reading Date Time Time Water Drop ~-,~' o o ~ "/~_ - PERCOLATION RATE ~ ~ (minutes/inch) 72-008 (6/79) ~ MU NICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 App~cahon Date GENERAL INFORMATION (a) Legal Description (.include lot, block, subdivision, secbon, township, range) Location (address or d~irecztionsl .i. (b)-X~p~ica;t N2me ~t-' :~Z~ Telephone: Ho,mo -~-O~O/ Business ~ (explain); .: (d) Le~ding Institution '~:~ ¢-~ Telephone ., Address (e) Real Estate Company and Agent ~~ , Address . : _ .. Telephone _ - .:-: ~::;: ,' -. (f Mail the__~A~ t~e ~llowing add~ess:.~__ .' ' ~ · . .. ..... ~ ~ '.-. -. ' '~ > :':::"% u' ' - ,. · :' / , . / ' . - :,kY' ..,~ ': :.~/.r:. ~.. :,.:. _.:: :,-: .... · ...,, . .... . · . . , ~ ~,,-& :'. .-:~, , 2 TYPE OF RES DENCE , , ~ ./ . : z;..- . ~-- ..... ~f . - '-. . . ..¢ ~/,,¢ - , --.:-~.: :,>;S~ngle-Famly~ Mulb-Famdy~ - Other . .... . . . '~. .. . .- :"'.::.'(;.?-?~ %:Number of Bec rooms , ) :'"' . .... : . ',:, ' · ~ : : : . -'"' - ,' ': ' ' ! -':' :" :"':' ~ """~"' s siem: ~U~;:hav;'w~ t~en':~:o~ii;mat'on from the ~iate Depa~t~n-";~;:~i ~h~i:~0nmen~a 'C~ns~rv~tion > '..-~; N0te:lfcommunitywe y ...... " "-. -' .'-attestin~ to the legality and status. ' _ 4. SEWAGE DISPOSAL ' · Onsite~]' Public [] Community [] Holding Tank / Note: if commumty well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status.' ...... ~ ....... - ............ -: .......... ' ...... :' · 72-025 1/84) Page I of 2 ENGINEERING FIRM PRovIDIN~.,~JSPECTIONS, TESTS, FILE SEARCH, DA"~AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe. functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection.__ Address ¢/,,~¢/~-~-~J?"~ --~.f '~-/~ ~ - Date / '/ DHEP APPROVAL '/~ App~:0ved for '~'~"'~':~bedrooms by ~ '~)' '~"'~'-~'~ Date ?~.r~pr~-d...,. ----- _~'_. ~ : ~ Disapproved' /x ... Conditional ' ~ Terms of Conditional Approgal _ CAU TION '- -' -~;~ The Viuncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority ~.! Approval certificates based solely upon the representations given in paragraph 5 above by an indeeendent professional engineer registered in the State of Alaska. The DHEP does [his as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate.~s issued. The Municipality of Anchorage ~s not responsible for errors or.omissions in the. . _ profess]ona engineer's wed(. Page 2 of 2 72-025 [11/84) O~ ~Y~,(~,~I~ALTH AUTHORITY APPROVAL (HAA) ~' .,? ~,~HECKUST- FE"RUARY ~984 ~ ~ 264-4720 Total Depth ~ Cased to /~ ' Depth ~ ~u~ng ~/~ - ~h'~ Static Water Level ~ x Casing Height Above Ground/-~ Electrical Wiring in Conduit ~i~'/) Separation Distances from Well: To Septic/Holding Tank on Lot Pump Set At / ~z'z~/..~ J Sanitary Seal on Casin9 ~) -- Depression Around Wellhead (Y/~ ; On Adjoining Lots ; On Adjoining Lots To Nearest Edge of Absorption Field on Lot .///-.~_"~ / To Nearest Public Sewer Line ~/~'~)~--'~ To Nearest Public Sewer Cleanout/Manhole ~Y~,~,.~ '"~-, T.o!~learestSewerServiceLineon/Lot/ Water Sample Collected by ~/~-~b"~, ~/-/~"/~ ; Date Water Sample Test Results ! Comments B. SEPTIC/HOLDING TANK DATA Date Installed..~/~/&~ Size ./~.._~"~ NO, of Compartments Standpipes~)' /"-',Air-tight C.ps~)~ Foundation Depression over Tank (Y~ v_ / Date Last Pumped ~mp,,~/Ma,~t~,~n~ Con~act o~ ~i~ ~Y/N~ ~/~' ;~o~ Holding Tank High-Water Alarm (Y/N) ~/~ Temporary HoldingTank Permit (Y/N) Separation Distances from Septic/Holding Tank: To Water-Supply Well ./~JD / To Property Line .~.~-'~/ TO Water Main/Service Line _.'~/~ course To Building Foundation -~./(~ / TO Disposal Field -~' ~' To Stream, Pond, Lake, or Major Drainage Comments Page 1 of 2 72-026(1~/84) ABSORPTION FIELD DATA Soils Rating in Absorption S, trata Date Installed Width of Field Square Feet of Absorption Area .J/..-~ Depression over Field (Y/,N~ Results of Last Adequacy Te%t Separation Distance from Absorption Fie d~: To Water-Supply Well ,~ ,~t~,~ To Building Foundation .~,~" Lot To Water Main/Service Line To Stream/Pond/Lake/or Majo/Jai~age Course To Driveway, Parking Area, or Vehicle Storage Area Comments Length of Field ~2~2~/ Depth of Field . /¢*"~ Gravel Bed Thickness ~7' ~' Standpipes Present~,l) Date of Last Adequacy Test To Property Line __~YO j To Existing or Abandoned System on ;On Adjoining Lots To Cutbank (if present) ~'~",x/~'/~' · / ~j~ ~ LIFT STATION Date Installed Dimensions S, ize in Gallons Manhole/Access (Y/N 'Pump on" Leve, at ,?,¢ High Water Alarm Level at /( ~~e'nt-(-~;~' Tested for ~'"'~/_ Pumping Cycles during Adequacy Test. Meets MOA Electrical Codes (Y/N) ~ / / · ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I..~.~¢hecke/d, veri~e¢', or conformed to all MOA a,nd HAA guidelines in effect on the date of this inspection. Sigaed ~--)~ ~L/'~.~,/ Date Company ,/'~'~- ~ MOA No. ReceiptNo. /00 / 00 // / /~ ~at~ of P~yme~t / ¢ ¢~ / Amount:, Page 2 of 2 72-026 (11/84) DATE RECEIVED INSPECTION APPOINTMENTS TIME ,:. TIME TIME DATE DATE DATE INSPECTO MUNICIPALITY OF ANCHORAGE A4UNICIPALITy OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTIONE DEPT. Of  825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL SANITATION DIVISION Telephone 264-4720 REOUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWERI~F~H-J~, ~t~SJ~ DIRECTIONS: Complete all parts on page 1, Incomplete requests will not be processed. Please allow ten (10) days for processing. MAIl' lNG ADDRESS t¢7 PHONE PROPERTY RESI DENT/(If different from above) 2. BUYER PHONE MAILING ADDRESS 3. LE~DING INS~TITUTION PHONE M/~i LING ADDRESS/) ; 4. REALTOR/AGENT PHONE 5. LEGALDESCRIPTION,/.~ ~ .' r~~ / ~ ;TREET LOCATION TYPE OF RESIDENCE [] One ,~ Four [] Other__ 6. ~J~U MBER OF~BEDROOMS ..~ SINGLE FAMILY [] Two [] Five [] MULTIPLE FAMILY [] Three [] Six 7. WATER SUPPLY ,,~' INDIVIDUAL* * ATTACH WELL LOG. A well icg is required for all wells drilled COMMUNITY since June 1975. For wells drilled prior to that date, give well [] PUBLIC UTI LITY depth (attach Icg if available.) 8. SEWAGE DISPOSAL SYSTEM ¢~ INDIVIDUAL/ON-SITE** /~-¢¢~ YEAR ON-SITE SYSTEM WAS INSTALLED. [] PUBLIC UTILITY NOTE: THE iNSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. , THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2, WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY ' DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3, SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [~] I NDIVI DUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER E~Septic Tank or [] Holding Tank Size: If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4, DISTANCES WELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5, COMMENTS d~L-~A~PROVED FOR ~ BEDROOMS [] CONDITIONAL APPROVAL (latter must accompany certificate) 72-O10 (Rev. 6/79)