Loading...
HomeMy WebLinkAboutTALUS WEST BLK 3 LT 3- Ol - Sm ~ Municipality of Anchor:lge Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ~'~/~(P~ 0 --~°E~! PID Number: Name:Wastewater System: D New ~ Upgrade Address: ABSORPTION FIELD Phone: Ne. of BeSoms: ~Deep Trench ~ Shallow Trench ~ Bed ~ Mound ~ Other LEGAL DESCRIPTION Soil Rating: Tolal Depth from original grade: ~, ~ GPD/Sq. Ft. WELL:D New D Upgrade G~w~wia~h: .~ Ft. Numberoflines: Classification (Private. A,B,C): Total Depth: Cased To: Total absorptiot area: Pipe material: Driller: Date Drilled: StaticWater Level: Installer: Datem ~nstai stalled: SEPARATION DISTANCES ~Septic D Holding D S.T.E.P. TO Seplic Absorption Lift Holding =ub~ic/Pdvate Manufacturer: Capacity in gallons: Material: Number of Compadments: Surface w~t~ ~ ~o ~/~ LIFT STATION Lot Size in gallons: ~ Manufacturer: Line ~ ~ ~ I "P~mp on" leve~ ~t: ~ "Pump off" level ah ~ High water alarm et: Foundation -5~ 7Z/ I C~ta~n t~}~ ~ ~ Pump Make & Mode~l Inspections pedormed by: Remarks: BENCH' MARK EN~;~. ~EAL Inspections performed by: Department of Health and Human Services approval ~eviewed anO approved by: ~ Oate 't~' 72-013 (Rev 9/91) MOA 25 2.5 49~.h BEN SPURKLAND No, CE-2~85 RS 50 7S lDO SCALE: ~" = 50 FL rOBBEM SPU£KLAND P.E. 205 W 15TH. AVENUE ARCH. AK. 99501 (907) 279-$916 / x\ \ ZD % % \ \ STANDARD SEPTIC SYSTEE: 1250 GALLON SEPTIC TANK 84 LINEAR FEET OF TRENCH 9 FEET TOTAL DEPTH 6 FEET EFFECTIVE ROCK DEPTH SKIING TIES; AB 19.6 FT AC 59,0 BC ,30 VALVE AD 54 BD 48 ~.T AE 74.5 BE 77.5 125 / 1.50 I / I LOT 3 B£OCK 3 TM]US din ADLER DilVE 11976 WILDERNESS SEPTIC SYSTEI~ ASI BUILT mm ocr. 9, 1998 SHEET: 2/$ O/~O: 2756 PERMIT # SI,/980337 PIE # 01_5-~0!-S2 TAI/O302£,D~6 Cleon Out Monitor Cleon Out Stondorcl Trenches; $4~ Lon9 9' Deep 6' Sewer 3' CoVeR Monitor ~ ZO200 FLOP/ DIVENIEN >Double Cleon Outs 1£50 9a[ Septic tonk Cleon Out TO HOUSE ~TBARRIER-- INV 89.2 $ 0 BOll, y FLOW SPLITTER ENDS "-"-'-'"--- 84.0 BOTH ENDS 92.$7 IPSO SEPTIC TANK NO SCALE BENCH MARK, CONCRETE SLAD ASSUMED ELEV, 100,00 TOBBEN gPURKLAND P,E, ~03 W15th Ave Anchonoge Ak 99501 LOT 3 BLOCK 3 TALUS VEST JIM ADLER 11976 VILDERNESS DRIVE SEPTIC SYSTEM AS BUILT SHEET, 3/3 GRIB, 2736 PERMIT II SV980337 PID# 051-£01-5£ TAVOSO33,DV6 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SiTE WASTEWATER DISPOSAL SYSTEM PERMIT 7' Upgrade Date Issued: Sep 03, 1998 Expiration Date: Sep 03, 1999 Permit Number: SW980337 Legal Description: TALUS WEST BLK 3 LT 3 Design Engineer: 0007 Tobben Spurkland, PE Owner Name: Jim Adler Owner Address: 11976 Wilderness Drive Anchorage, AK 99516-2238 Parcel ID: 015-201-52 Site Address: 011976 WILDERNESS DR Lot Size: 20528 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ~ ''~'- ~ Date: ToSP ANE) 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 3 BLOCK 3 TALUS WEST JIM ADLER Municipality of Anchorage Department of Health and Social Services 820 1 Street . Anchorage, Alaska 99501 We are submitting an application for septic system up grade for this lot. The submittal consists of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only septic system is subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed. The septic system design is based on the following: No Ground Water or Impervious Layer to 15 ft. Use Standard Trench Soil Rating. From Testholes Aug. 18, 1998 30 min/in = 0.6 gal per sq.ft/day No. of Bedrooms 4 Required Area per Bedroom: 150/.6 = 250 sq.ft. Total area required: 250 x 4= 1000 sqft Testhole depth 15 feet Bottom Rock At 9 feet Top Rock At 3 feet Rock Depth 6 feet Total Trench Length 1000 / 12 - 83.3 ft. SYSTEM CONFIGURATION STANDARD TRENCH TOTAL LENGTH 84 FT TOTAL WIDTH 2 FT TOTAL DEPTH 9 FT ROCK DEPTH 6 FT COVER 3 FT SEPTIC TANK 1250 GAL The installation of this septic system will not prevent wells from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. ~5 24 ! \ i TRAVERSE k/AY SCALE~ F' = 100 FT, D£IVE JTOBBEN SPURKLAND P.E. 205 W ISTH. AVENUE ARCH. AK. 99501 PE/~MI? # SF98XXXX Il LOT 3 BLOCK 3 TALUS WEST J/N ADLER 11976 WILDERNESS DRIVE IlSEPTIC SYSTEM DESIGN DATE: AUG, Z1, 1998 SHEET: 1/5 GRID: 2756 TA k/fi3fi3i, D F6 Pig # 015-201-52 50 75 S£AL£: i~ = 50 FT. 125 I I i/ __ I STANDARD SEPtiC SYSTEId: 1250 GALLON SEPTIC TANK 84 LINEAR FEET OF TRENCH £ FEET TOTAL DEPTH 6 FEET EFFECTIVE ROCK DEPTH VALVE 1250 GAL. S.T TOBBEN SPURKLAND P.E. 205 W 15TH. AVENUE ANCH. AK. 99501 (907) 279-$916 PERMIT Il £~98XXXX [ LOT 3 B£OCK 3 TAI~U$ ~EST J/N ADLER Di/VE 11976 W/LDERNESS [ SEPTIC SYSTEM D~SIGN OATE: AUO. 2i, 1798 SNEET.'i/3 z7 6 PID # 015 20i 52 F ~T PJonltor Cleon Out Sizondomd ?renches: £' Wide ~£' Lono 9' Deep 6' ~ewer rock ~' Cover ZD £00 FLDW SPLITTER ND SCALE £~0~ SPLITTER NI7 SCALE 1£50 SEPT[£ TANK BENCH MA£~ ASSUMED ELE~ lOgO0 TQBBEN SPURKLAND P,£, 203 ~15th Ave Anchopcge Ak 99501 LOT 3 BLOCK 3 TALUS WES~ JIM ADLE£ ]1975 ~/ILDEP`NES£ DP`IVE SEPTIC SYSTEM DESIGN ~ATE~ A~. 21~ SHEET, 2/$ G~ID: ~72~ PEP, MIT # SW98XXXX P]~# 05~-~01.-5£ TAWOJO33,~]W6 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: ~'} ~. Vl/'l /~ l ~-~¢~ LEGAL DESCRIPTION: T'/51L.'L,) -~> 1 2 3 4- 5- 6- 7 8 9 10 11 12 13 14- 15- 16- 17 18 19 20 COMMENTS Township, Range, Section: ~;/,~y ~,,.~.¢4¢2 SLOPE WAS GROUND WATER ~. [ ENCOUNTERED? l~4 0 SITE PLAN S L IF YES, AT WHAT O DEPTH? p E Depth to Water Alter / . Monitoring'/' ~:~'/ Date. ~///,~'-~/~' ~A o~T' Gross Net Depth-t~ Net Reading Date Fl k J~ ~ .j~.~ .~ ~ Time Time ~ ~ Drop : ¢o ~o &//~ Io" __~ ~;~o ~o 7 'IV l°" PERCOLATION RATE ~ (minutes/inch) PERC HOLE DIAMETER __ TEST RUN BETWEEN ~ FT AND 5 ~'~-- FT PEB~ORMED B~: '77 ~' I I- ~ OERT,~ TH^T TH,S TEST WAS "ER~ORMED,N ACCOBDA.CE W~TH ALL STATE AND MUN,C,PAL GU,~,C~L,NES,N E~ECT oN ~H,S DATE. DA~E: /~. 72.008 {Rev. 4185) ~nchorag~, Alask~ 99502 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM N? 868 r PHONE~?T)~ ADDRESS LEGAL DESCRIPTION ~'~'~//(': SEPTIC TANK: DISTANCE FROM WELL LIQUID CAPACITY ~ ~<~:~:~/ NUMBER OF MATERIAl .COMPARTMENTS· GALLONS. INSIDE LENGTH_ INSIDE WIDTH LIQUID DEPTH __ SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS / OUTSIDE DIAMETER NEAREST LOT L,NE ~'~ '(-) OR WIDTH DISTA'"CE EROM WEL~ //~ TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA). .LENGTH ~ ~'/' / DEPTH ~ /' · BUILDING FOUNDAIION~ sQ. ET. TILE DRAIN FIELD: DISTANCE FROM WELL NUMBER OF LI~.~ ABSORPTI?N//AREA / , F~U~ , NEAREST LOT LINE DISTANCE BETWEEN LINES TRENCH WIDTH SQ. FT. LENGTH OF EACH LINE ~ TOTAL LENGTH , OF LINES I N~.~T'A~LL EFFECTIVE DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE WELL: )' ' /~ x Typ E~)/<~;,//C:~ , DEPTH LOT LINE ~-~--' / ~-~ ~ NEAREST ~ SEPTIC , SEWER LINE ., TANK DISTANCE FROM WATER ., BUILDING FOUNDATION, SAMPLE ~.-_:,, SEEPAGE //~/ ., NEAREST OTHER , SOURCES DISTANCES: :?v , . DIAGRAM OF SYSTEM DATE APPROV r ./~E ALT H AUTHORITY GrE~-LR ANCHORAGE AREA BOF~iUGH DEPARTMENT OF ENVIRONMENTAL QUALITY SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT PHONE INSTALLATION Of: SEPTIC TANK SEEPAGE PIT D, RAIN / / / NOTE: T~S OTHER TO BE INSTALLED FINANCED THROUGH COMPLETION DATE ANTICIPATED //~'l 7 FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. DEPARTMENT OF ENVIRONMENTAL QUALITY OF/ANY SY FINAL INSPECTION BY THE IJECT TO 'ROSECUTION. MINIMUM DISTANCES, REQUIRE [E?'NTS SIZE TYPE DIAGRAM OF SYSTEM FOUNDATION TO SEPTIC TANK -- FOUNDATION TO SEEPAGE PIT SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK SEEPAI TO NEAREST LOT LINE. WELL TO SEPTIC TANK ~RA'N F'ELD /~O' WATER MAiN TO SEPTIC TANK / ~RAm F'ELD Pit , DRAIN FiE[ SEEPAGE ~'T i~0 I ALSO CONSIDER AREA V ELLS. SEEPAGE PIT ~/0 I CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION, I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHO AGE AREA BOROUGH ORDINANCE NO. 28.68 AND THAT THE ABOVE DATE ' "7 ? APPLICANT'~ $]GNATURE ~ E0-016(3-75) W ~'* SEWAGE DISPOSAL SYSTEM m APPLICATION AND PERMIT INSTALLATION LOCATION PHONE~'% <~- ~ ~ ~ INSTALLATION OF: SEPTIC TANK SEEPAGE PIT ~ DRAIN FIELD OTHER TYPE AND SIZE OF fACILITY TO BE SERVED ~ ~1/~ '2:0 ~,~.(-; i~ ~ ~ J~ J{~ COMPLETION DAT[ ANTICIPATED % ' FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSP HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE J -~¢~' () C/~ [ TYPe '~'')'' E-~-I I~ (_ ('O L~[;-$~EPAGE WATER MAIN TO SEPTIC TANK ~/0 / , SEEPAGE PIT /~ DIA~RA~ OF BYBTEM SEPTIC TANK* SEEPAGE PIT DRAIN FIELD TO RIVER. LAK~. STREAM. CAST IRON INTO AND OUT OP SEPTIC TANK AND INTO CRIB CROSSING GAP OJ~ EXCAVATIO~ 4 INCH D~J~E~EI~ CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE Pit GRAVBL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. 3 oo TUDOR ROAD ANCHORAGE, ALASKA 99502 Performed For ~ A/< ~-.- Legal Description': Lot'/~B~ ~Subdivision Date ~Perf°rmed. ,, This Form Reports Soils--[-~g_~,,~i. ...... Percolation~'~ ~u~Test"' Depth Feet 7 Soil Characteris~ics_~_____ Was Ground Water Encountered? If Yes, At What Depth? Reading Date Gross Time [ Net Time Depth to H20 Net Drop Percolatinn R~t~ M~.,,+~ Proposed Insta'~lation: Seepage Pit Drain Field Depth Of Inlet Depth To Bottom Of Pit ~)~ Trench COMMENTS: ~ ,~-~-> Test :~.ur.~u Dy,. ~ ~' '/ Da~a Ce~i~ed By: /// ~'~ ~ Date:' N APPLL_ ,NT FILLS OUT UPPER HA . ONLY Address Zip Oode Address Zip Code Realty Co. & Agent Phone Address ~' Zip Code Legal Bescription ~ ~ ~ Street Locatim ~ ~ ~idual A~ACH WELL LOG. A w~l log is required for all wells drilled since June 1975. ~ Community For wells drilled prior to ,that date, give well depth (attach log if available). ~ Public Utility Sewer Disposal ~ ~. ~vidual Year Individual Installed: ~ Public Utility When Connected to Public Utility; ~ Holding Tank NOTE: THE ~NSPECTION FEE MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSING CAN BE INITIATED. Time Timel' I ' Ti¥~e~' ~3 Time Date Date Date Date DEPT. OF HEALTH & ~ O~ ENVIRONMENTAL PROTECTION RECEIVED ~) APPROVED BEDROOMS *CONDITIONS OF APPROVAL ( ( ) DISAPPROVED ( ) CONDITIONAL APPROVAL' DATE ~' J J ~ ~ x Soils Rating Date ~wer Installed Well To Absorption Area ~] ~ Well Log Received ~-- ~ ~ Well to Tank ~ ~ Septic T~k Size I ~ 72.023 (31821 July 8, 1983 John C. Riley SRA Box 1685C Anchorage, AK 99507 ;Subject: Lot 3, Block 3, Talus West Approval for the individual sewer and ~ater facilitiee cannot be granted until the folle~eing items have been corapteted: ° The septic tank puu]ped with a receipt submitted to this An adequacy test needs to be performed on the existing leaching area. This test will deter~ine if the system is adequate according to National Standards. A listing of private firms performing the test is euclosed. This report needs to be sub~nitted to this office for our review. Please notify this Departn~ent for a reinspectiou when the noted discrepancies have been corrected. If there are any further questions, please call this affice at 264-4720. ginceraly~ Robert C. Associate Pratt Environmental Specialist '~ D~ RECEIVED -, INSPECTION APPOINTMENTS ~-~-j~/~{~_, TIME TIME TIME DATE DATE DATE MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE DEPT. OF H~J~LTH & ENVIRONMENTAL SANITATION DIVISION P~U~ 6 1980 Telephone 264-4720 DIRECTIONS: Complete ali parts on page 1. Incomplete reques~ will not be proce~ed. Please allow ten (10) days for processing. MAILIN6 ADDRESS PROPERTY RESIDENT (If different from above) PHONE MAILING ADDRESS STREET LOCATION NUMBER OF~BED~OOMS 6. TYPE OF RESIDENCE , / ~ SINGLE FAMILY [] Two LJ Five One Four [] MULTIPLE FAMILY [] Three [] Six [] Other 7. WATER SUPPLY  INDIVIDUAL* *ATTACH WELL LOG. A well log is required for all wells drilled COMMUNITY since June 1975. For wells drilled prior to that date, give well [] PUBLIC UTI LITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM ~ INDIVIDUAL/ON-SITE** YEAR ON-SITE SYSTEM WAS INSTALLED. [] PUBLIC UTI LITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 ( Rev. 6/79) ~ THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE NUMBER CE BEDROOMS [] SINGLE FAMILY [] ONE E~ TFIREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FQUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTI LITY Connection Verified LOG RECEIVED 3, SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIViDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY ~) ~-~ ~'2~. Connection Verified INSTALLER []Septic Tank or [] Holding Tank Size: I~:~_.._lfTankishomemade SOILSRATING give dimensions: TYPE OF TANK MANUFACTURER TOTA'ABSOR TIONAREA MATE.IAL 4, DISTANCES"wELL TO: Septic/Holdlng~ .,~.lTank Absorption~ ~Arear' Sewer Line Nearest Lot Line Absorption Area t-o nearest Lot Line 5, COMMENTS FOR '~ BEDROOMS [~"JAPPROV ED [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED DATE BY 72-010 (Rev. 6/79) · RE2 REID ENVIRONMENTAL ENGINEERING 5RA BOX 1584R ANCHORAGE, ALASKA 99507 (907) 344-] 205 MUNICIPALITY OF ANCHORAGE ,.., DEPT. OF J-i~, ,LI',~ & '~'" E~qV RONMENTAL F ,b i ['CT ON RECEIVED THE: SYS'?~;H ZS CAF?~J~:L.E: OF:' AJ3C~EF:'T~}.:N6 630 G/~L..L.~NS OF' N~¥~"E:R F'E[:~'. DP.Y~ ZS i65 8(~?'T/ DEDRqX~H., D~:~:D L?[)N 'T]"I~:~: 'Ti~:ST [){:~'i*t~ 'i'Hl~: SYf~Y!ZH THE ~E?'¥'Z:C 'T~NK N~S F'UHF:'~]~:D (:)N dULY April 10~ 1978 #76137 Leroy Reid Star ~ute A Box 1584-R ~ulohorage~ Alaska 99507 Subject: Per~,..~tt Expiration A permit issue~ by this department for well and/or on-site sewer installation on Lot 3 Block 3 Talus West Subdivision has expired since the issue da~e exceeds one(l) year. In the event that you w~t to still in~Alltb~essystem, a new pe~it is req%~ired from this office. If you have any questions regarding the above matter, please contact this office i~nediatety at 264-4720. Sincerely, Les N. Buchholz, Senior Environmental Specialist GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 1. Approval requested by: Mailing Address: 2. Property Owner: ~ Date Received Time of Inspection Date of Inspection REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES Phone: Phone: Mailing Address: 3. Legal Description: /~ 5 //~ 4. Location: '~-/~ (]~zb. 5. Type of facility to be inspected ~No. of bedrooms J Well Data: A. Type ~ C. Construction 7. Sewage Disposal System: A. Installed /q2/ B. Depth O. Bacterial Analysis .~.~(~ ~6~B. Installer C. Septic Tank: 1. Size /~o D. Seepage Pit: 1. Absorption Area ~ E. Disposal Field: Total length of lines Distances: / A. Well to: Septic tank ~2 , Absorption area Nearest lot line ~ , Other contamination / B. Foundation to septic tank ~ , Absorption area C. Absorption area to nearest lot lin~ ~( ~ ~/ 2. Manufacturer 2. Material Sewer Lines __, EQ-034 (1/74) Page 1 of two pages ' · Page 2 of two pages - Re~st for Approval of Individual S~..~r & Water Facilities Legal Description ~2~ ~ ~>/~/~ ~ J~ /xc/~/Y Approved z~'~d.~~ Disapproved Date Approval Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ-D34 Department of gnvironaental quality It g}lO RA~I D Ui-i TO: I~cord heroy C. Retd~ Jr. Director et Enviro~entel ~enty-~ev~ o~ ~ator in it and total depth of ohs hundred an~ et~ire p~p~ period. Thi~ ~ould indicate that t~ el~v~ h~red and slzte~ ~allo~ si ~a~er d~a~ fro~ tha~ test ~11 tn ~h~ ~txhour did ~ot ~ve the circle of Influence ou~ard to test ~ell n~ber~ sue. Mrs Wright, a builder in t~area ~nd a £or~er well driller, tie indicated thac last August ha had ~un his ~tll for a ~o v~ek period at au esti~ated rets of 5. ~pm, and had not depleted the wate~ lavel iu h~s ~all. It would indicate that tentatively sufficient ~ater ~ere avallabl~ in the Talus West Subdivision~ providint tha~ thh~slls ~ properly developed ~lth at least sixty-nine fast of space batwe~ each veil, hCR:p3h November 24, 1971 Chuck's Backhoe 8101 Seward Highway Anchorage, Alaska 99502 Subject: Installation of On-site Sewage Disposal Lot 3, Block 3, Talus West Subdivision. System on Dear Sir: Upon inspection of said system, ! was not informed of the need- ed absorption area of the seepage pit and therefore stated that the said system could be eovered at your own risk. Having later received a copy of the soil test It has been discovered that the pit is undersize by 168 square feet of absorption area. In order tO remedy this situation, either the permit must be changed to a three bedroom dwelling or the p,it must be enlarged. Your cooperation in this manner within five days from receipt of this letter would be appreciated. If, however., this situa- 'on remains unchanged after the specific time ha~ expffed, Mt procedures shall be started against~you. ~t tel Officer