HomeMy WebLinkAboutTALUS WEST BLK 3 LT 12 Municipality of Anchorage Page 1 of_.3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Bo,~ 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW980201 PIDNumber: 015-201 -43 Norman & Diana Buboltz WastewaterSystem: n New [] Upgrade 11876 Wilderness Dr. Anch., AK ABSORPTION FIELD Existir Phone: 3 4 5 -- 4 3 7 3 I NO. Of Se~roonls: Four O Deep Trench D Shallow Trench Q Bed r~ Mound ~ Other LEGAL DESCRIPTION ~Soil Rating: Total De.tn from original grade: .. 3 Talus Wes~ ~L ~. WELL: D New ~ Upgrade Gravel wiath: ~ Number of lines: Existinq Ft Ft. .~ ¢ ~ SO. Ft. Viel=: ~ Pump Set at: ~ Oasm~ He,~m A~ove '~-;~;: SEPARATION DISTANCES ~e~,~: S Ho~,.~ C S.T.~. Fro~';'" :~''' :; Tank F~ Station Tank S~U.. Anch. Tank 1 . 250 :~' wem~, >100 >100' N/A N/A >10' Steel ~ ~-' ?~Su~ace= >.~00~ >100' N/A N/A N/A LIFT STATION :None Cu~ain Remarks: Septic ~ank a~d t~o pos[ BENCH MARK tank c!eanouts placed under Lo~tion an~ D~cdption: this permit. Side of House. .~ ~ ~um~ m...~io.: 1 00.0 Inspections pedormed by: H~A Dates: 1st ~/29/9~ ~ ................. Padment of Health and Human Se~ces app ~ ~' De ~oval ~/~ . Reviewed and approved by: ~ ate: ,ff q' ~ ~7'%7~';q"'~"' UmF~H I IVI~_IN I Ur mi:AL I Pi ANU PIUMAN ENVIRONMENTAL SERVICES DIVISION P.O: Bo~ 196650 · Anchorage, Alaska 99519-6650 · Telephone: 3~-47~ On-Site Wastewater Disposal System and/or Well Inspection Repod Permit Numbe~ SW980201 PID Numbe~ 015-201-43 ~ ~ Abs~rption ~ under~ this perm~t.~ Exi~stin~ : system remains in ~serv~ce. DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Bo:~ 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number:. SW980201 PID Number. 015-201 -43 :~ ....... i'~ ~'~ ................ : ........... -~ ' 2" Insul ~t .on ~ank PROFILE AS'BUiLT ! i SCALE 10' MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.o. Box 196650, Anchorage, AK 99519~6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Jun 25, 1998 Expiration Date: Jun 25, 1999 Permit Number: SW980201 Legal Description: TALUS WEST BLK 3 LT 12 Design Engineer: Anderson Engineering Owner Name: Norman & Diana Buboltz OwnerAddress: 11876 Wilderness Drive Anchorage, AK 99516-2234 This permit is for the construction of: [] Disposal Field [] Septic Tank ~ Holding Tank Parcel ID: 015-201-43 Site Address: 011876 WILDERNESS DR Lot Size: 18514 SQ. FT. Total Bedrooms: ,8' i~ Permit Bedrooms: Privy [] Private Well [] Water Storage All construction must be in accordance with: 2. The attached approved design. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska 3. Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling 4. (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Date: Date: June 22, 1998 Municipality of Anchorage Department of Heath & Human Services 825 "L" Street Anchorage, AK 99502-0650 Subject: Lot 12, Block 3, Talus West Subdivision Septic System Design Impacts to Adjacent Properties Dear Onsite Services Engineer: We are hereby applying for a permit to construct a new septic tank on Lot 12, Block 3, Talus West Subdivision. The attached site plan and backup documentation identify the size and location of the new tank to serve the four bedroom home. The original tank was placed in the early 1970s with the absorption trench. The tank has now caved in creating a safety hazard in the yard and backing effluent into the house. It is imperative the tank be replaced immediately to avoid damage to property and impact to public health. The new tank will be placed in the exact location of the old tank. In addition, two new post tank cleanouts will be installed for future maintenance of the system. Soils surrounding the system are clean silty gravels and will provide satisfactory bedding for the tank. The well on the lot and those on adjacent lots are more than 100' from the tank and are shown on the site plan. No conflicts exist between the septic system and wells in the area. The surface of the lot is flat in the area of the tank making placement of the new tank relatively uneventful. The existing absorption trench was not inspected for adequacy, but according to the property owner is currently operating without problems. The owner of the property is aware that the trench will require upgrading if the house is to be sold as four bedrooms. Eot 12, Block 3, Talus West Subdivision June 22, 1998 Page Two If the system is constructed as designed the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, impact on reserved space, either surface located in the area. will have no adverse er subsurface, on any lots The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attaohments LoT 13 J _% LOT 12 Tr~ New 1,250 Gallo Septic Tank with 2 Post Tank Cle Four B~d~60m Home SCOPE OF WORK 1. Remove Existing Septic Tank and Disp'ose. 2. Place New 1,250 Gallon Septic Tank. 3. Place Two New Post Tank Cleanouts. .~ 4. Regrade Area to Preconstructi0n Condition. "'~ ................ '~:" SITE PLAN ~ ~" ~'~'"" "~ ......... ~" "f' 30' ~',~,. 4381-~ /,??, SCALE 1" = LOT 11 Well O ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 12, BLOCK 3, TALUS WEST SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,250 gallon septic tank. It also includes the construction of two new post tank cleanouts in the distribution line between the new tank and the existing absorption trench. The existing tank must be removed from the site or crushed and backfilled on the lot at a location 100' from all wells in the area. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for underground utility locates and for the layout system and verification of the location of all obtaining all of the septic lot lines. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,250 gallon septic tank must be procured from an approved source and installed at the location shown. Lot 12, Block 3, Talus West Subdivision June 22, 1998 Page Two A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Lot 12, Block 3, Talus West Subdivision June 22, 1998 Page Three Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and Solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI of equal). 4. Septic tank inlets and outlets shall be fitted watertight couplings (Caulder, Fernco, or equal). with Lot 12, Block 3, Talus West Subdivision June 22, 1998 Page Four 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: A minimum of two inspections are required by Municipal Ordinance. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. I:K ANLUUI(AL~I: ANI:A BO~ UGH ~/-, Department of Environmental (~uaJity 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: DISTANCE FROM WELL,., INSIDE LENGTH ---. MAN U FACTU RE RL(~/~' ~!/d' ',.S (/2:E·/;~ NUMBER OF MATERIALL~"/?~'~. ~(///"/J'//)~2~2~COMPARTMENTS ,,2 INSIDE WIDTH .... LIQUID DEPTH -~ I IQUID CAPACITY. /-~---/;~) GALLONS. SEEPAGE PIT: NUMBER OF PITS / DIAMETER LINING MATERIAL.~LL!O /-cL~k~¢?:) CRIB SIZE: BUILDING FOUNDATION -~[ i OR WIDTH'~'-~, ,/TLENGTH,~ ,~/ DEPTH DIAMETER¢;4:¢) DEPTH ('~ DISTANCE FROM: TOTAL EFFECTIVE ADDITIONAL ABSORPTION, NEAREST LOT LINE ~(/ ! WELL ABSORPTION AREA (WALL AREA) d-~2--~ SQ. FT. WELL: TYPE BUILDING FOUNDATION APPROVED CONSTRUCTION ~' ~¢/~i/.,~///(~' NEAREST / NEAREST f./. SEPTIC LOT LINE /(? SEWER LINE /4') TANK OTHER SOURCES /vd,.'L¢ DISAPPROVED REMARKS DISTANCE FROM: SEEPAGE / SYSTEM /~,,!~9 DISTANCES: DIAGRAM Of SYSTEM INSTALLED BY: PIPE MATERIAL: APPROVED /)f G.A.A.B. Form No. LQ-031 Grea~Er ANChorage AREA BOrOUgh DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99§03 TELEPHONE 274-4S6, SEWAGE DISPOSAL SYSTEM m APPLICATION AND PERMIT PERMIT NO NAME OF APPLICANT iNSTALLATiON LOCATION LEGAL DESCRIPTION ~ ~ 7- INSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH MAILING ADDRESS SEEPAGE PIT . DRAIN FIELD PHONE · OTHER NOTE: THI~ PERMIT IS NOT VALID WITHOUT BOIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION, SEPTIC TANK SIZE /2~r~) TYPE ~/~/~' ~/~-E~ SEEPAGE AREA SIZE TYPE MINIMUM DISTANCES, REQUIREMENTG FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT SEPTIC TANK TO SEEPAGE PIT WALL -'~WELL TO SEPTIC TANK /l~/~ / /..T / ., SEEPAGE PIT / TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRI~ CROSSING GAP OF EXCAVATION 5 Feet INTO UNDISTURBED SOil. 4 INCH DIAMETER CAST [RON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH A~RTiGHT REMOVABLe CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. LICENSED DESI~; NCR I CerTIfY THAT I AM Familiar WITH THE REQUIREMENTS OF GREATER ANCHORAge AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. ~ ,. .~1 GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3500 Tudor Road, Anchorage, Alaske 99507 279~8686 Time of Inspection /~ Date of Inspection x<~ r~~ REQUEST FOR AP~OVAn OF ~ I~IVIDUAL SEWER & WATER FACILITIES FOR Address: Phone A. T yDe~_~ , B. Depth 7. Sewage. Dis.6os~l System: .. E. Disposal Field: Total Lengt~f Lines = . , Dtstences: , . A. Well To: Septic Tank ~t ,~Absor~ Area /~2~/ , Jewer Line~ B. Foundation to Septic Tank f~+ ~oti~~ ~ . C. Absorption Ares to Nearest Lot Line ~x .,<= ,-~ ~ Req,~ezt for Approval of inoiviouai Sewer & Water Facilities Page Two 9, Comments: ~v~ Ap?royal Valid for One Year From Date Signed Gr~e~ Anchorage Area Borough, DeF~rtment of Environmental Quality DIAGRAM OF SYSTEM I certify that the information contained in this request for approval to be a true and accurate representation of the subject sawer and water facilities located at: Signed Date and Sewe~r ,artment of Environmental Quali~ :uestionnaire ~ te. Time Subdivision ~'/~L f( 3 ~g_~Jc~.' ~// ' · , Block Owner's Name: ~./~/~/))~S />/. /~zfYz~ ~////~g//~ /~, Mailing Address: ~.~. /~ 6.~?v =~.~.~ ~ ~;~ ~(~/~o~, Questions: 1. How many bedrooms are now in your house? 2. How many bedrooms were in the house at the time of purchase~ 3. ~vere the basement bedroom walls roughed in" at the time of purchase? 4. Was the basement bathroom plumbing "roughed in" at the time of purchase? ~ 5. Did the realtor or builder inform you that you would have to enlarge the existing sewer system if you finished the basement bedroom (s)? 6. If on a public~ water supply, do you always have an adequate supply of water? Is the pressure always adequate? ,~ Who was the builder? ~/~/~/~'~ ~)~/~T~ Who was the home purchased from? OTHER COMMENTS: