HomeMy WebLinkAboutTALUS WEST BLK 3 LT 13Talus West lock Lot I 015- 01 -42: On-Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP111202 Tax Code Number: 01520142000 Work Type: Septic Upgrade Permit Effective Dates: August 19, 2011 to Design Engineer: SPURKLAND ENGINEERING Subdivision: TALUS WEST Site Legal Address: Owner/Address: August 18, 2012 TALUS WEST BLK 3 LT 13 G:2736 MOSELEY RUTH G 11866 WILDERNESS DR ANCHORAGE AK 995162234 Site Mailing Address: 11866 WILDERNESS DR, Anchorage Lot Size in Sq Ft: 19318 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field N Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The permit includes waiver OSP111203, allowing the drainfield to be 2 feet from the property line and 6 feet from the existing crib drainfield. Received By: Date: Date: Municipality of Anchorage P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997 htto:l/www, m u ni.orq/Onsite Development Services Department On-Site Water and Wastewater Program ,epartment **** VARIANCE/WAIVER REVIEW **** WR#: OSP111203 HA#:~ Permit~: OSPl11202 PIDg: 015-201-42 Legal Description: Talus West, Block 3, Lot 13 Engineer: Spurkland En.qineerin.q Applicant: Charles Mseley Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 2 feet. Your request for a waiver of the required 10 feet horizontal separation from the absorptiOn field to the absorption field (crib) has been approved. The approved separation' distance is 6 feet. This waiver approval applies to the permitted design only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: 8/19/11 Appmv [.~' Name of Reviewer Rec~: 084147 Amount:' $200.00 Date Paid: 8/8/2011 **** VARIANCE/WAIVER REVIEW **** Community Development Department Development Services Division On-Site Water & Wastewater Program I UNICIPALITY OF ANCHORAGE ~' '~ Phone: 907-343-7904 ~ Fax: 907-343-7997 Mayor Dan Suflivan ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 015 - ?,ol'- ~/Z. Property owner(s) Mailing address It Site address - Day phone AK Legal description (Sub'd., Block & Lot) T^I~ W'~,~ [~t~.,~. ;~ Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms THIS APPLICATION ([~ all that apply) Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage IS FOR: THIS APPLICATION IS AN: Initial [] Upgrade J~ Renewal [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. ~ ~ Waiver Fees: Date of Payment: Receipt Number: G:\Buiiding\On Site\Forms\Client Forms\Permit App_010411 .doc (Rev. 1/11 ) Environmental Consulting and Design SEPTIC SYSTEM DESIGN Talus West Block 3 Lot 13 Municipality of Anchorage Development Services Department On Site Water and Wastewater Program 4700 Elmore Rd. Anchorage, Alaska 99519 August 5,2011 Subject: Septic System Installation Permit Ladies and Gentlemen: I am writing to request a permit to upgrade the septic system for the above referenced property. The septic tank was replaced in 2004. A new deep trench drain field is proposed. Soil logs, design calculations, a site plan, design drawings and construction specifications are enclosed for your review. Design Calcs: No Groundwater observed to a depth of 15.5 feet below ground surface (8/5/2011) Soil Rating. From Testhole 7/12/2011 5.3 min/in = 0.8 gal per sq.ft/day No. of Bedrooms 4 Required Area per Bedroom: 150/0.8 =188 sq.fi. Total area required: 188 x 4 = 752 sqfi System: We are proposing a deep trench absorption field connected to the existing septic tank The absorption field will be 80 feet long and 2 feet wide and contain 6.5 feet (1000 sq.ft, effective) of sewer rock. Soils: A test hole was excavated on July 12, 2011. See the attached soil logs. Ground water was monitored for through August 5,2011. Ground water was not observed in the test hole. The total depth of the test hole was 15.5 feet. We are proposing a maximum depth of our drain field to be 11.5 feet. A review of soils logs and well logs from neighboring properties show consistent soil horizons with what was observed in my soils analysis. No impermeable layers where noted to a depth of 20 feet. Surface Water: No surface waters were observed within one hundred feet of the proposed septic system. Topography: The lot rises slightly to the south west. Slopes do not exceed 5%. A elevation variation of 2-3 feet will exists over the length of the trench. Waivers: A lot line waiver will be required. The lot to the west is already developed and no 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland~gci. net Environmental Consulting and Design I adverse impacts are anticipated. We request a waiver to reduce this set back to 2 feet. The shape of the existing crib is irregular and determining its outer extents is not possible without substantial excavation. The proposed trench may encroach upon the 10 foot setback. We request a waiver to reduce this setback to 6 feet. No adverse impacts are anticipated in granting this waiver. The installation of this septic system will not prevent wells and septic systems from being installed on the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. If you have any questions or concerns, please contact me at 279-3916. Sincerely, Civil Engineer 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland~gci.net Environmental Consulting and Design SEPTIC SYSTEM DESIGN Talus West Block 3 Lot 13 Municipality of Anchorage Development Services Department On Site Water and Wastewater Program 4700 Elmore Rd. Anchorage, Alaska 99519 August 18, 2011 Subject: Septic System Installation Permit 11866 Wilderness Drive Ladies and Gentlemen: I am writing to address several of the comments received from the Onsite Program after review the septic system installation permit for the above referenced property. 6. Ground water: Ground water was not observed during the excavation of the test hole. Current code requirements specify that the bottom of the proposed drain field be 4 feet above seasonal high ground water levels. Onsite Program has been requiring an additional 2 feet of vertical separation during the months of July and August to account for seasonal variations in ground water levels. To my knowledge Talus West S/D does not have a shallow ground water table. A review of test holes on neighboring properties appears to confirm this. A test hole excavated at Talus West Lot 14 Block 3 did not encounter ground water. The total depth of this test hole was 18 feet. 7. Bedrock: A review of test holes and well logs for the neighboring properties indicates that the depth to bed rock is over 150 feet. No impermeable layers are noted in the well logs for Talus West S/D Block 3 Lot 13, Block 4 Lot 3 and Block 3 Lot 20. Test holes on Block 3 Lot 14 and Block 4 Lot 3 were excavated to a depth of 18 feet. No impermeable layers were noted. 8. Percolation Test Location: Based upon the observed percolation rate, a minimum absorption area of 752 sq. feet is required. With an effective depth of 6.5 feet, the minimum trench length required is 58 feet. This entire area is within 30 feet of the test hole. 9. Drain Field Orientation: The ground surface rises 2-3 feet along south end the trench. The ground surface elevation is at the test hole is close to the low point of the trench. The proposed trench location will maintain the required separation from ground water and impermeable layers and will maintain a minimum of 4 feet of cover over the field. If you have any questions or concerns, please contact me at 279-3916. Sincerely, Lars Spurkland, P.E. 203 West 15t~ Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland~gci. net ,' l ,' ~sr ~4 I ~~ / ~/ -~' ' [~,~- - ~ - ~ ~ v ~ , ~'"' /~ ,',, % ~k 'C~~~._/ ~ ~~~~ ' ,, ~~. :: x~~...~....~b,, I NOTE: THIS IS NOT ~ SURV~EO P~[ WE~ · SEPTIC ~ ~ ~/ ~ LOCATIONS TAKEN F~ ON-SITE ~A~R ANO WASTE WATER ~ '~' 49~. , ~ DEPARTMENT ~U~E~AT/ON. A~ LOCATIONS SHO~ ARE ~""P'~ ........ r~ .... 7;7 ..... ~'"'~ J ~ ,PP~OX/~,TE. ~....k~..,..3Wjk%,;;.~,...e ~' , '*;~& ..... ~/, ~/./¢....:r~ SPURK~ND ENGINEERING LOT 13 BLOCK 3 TALUS ~EST SEPTIC SYSrE~ 20~ W 15TH. AVENUE Chor/es ~ose/ey DA~E: AUG. 4, 2011 ANCH. AK. 99501 (907) 279-~916 11866 WILDERNESS DRIVE, ANCHORAG~ AK 99516 SHEET: 1/~ GRID: 27~6 PERMIT ff O~P]]]]XX PID ~ 015-~0]-4~ TAL U~E~ T~3L]3D],D~G / I I / / / LOT !4 STAKE LOT LINE BY REGISETER LANO SURVEYOR I / / L LOT ~! INSTALL 4-BEOROOM DRAM F/ELD EXISTING 1500 GALLON STEP TANK LENGTH 80 FEET WIDTH 2 FEET TOTAL DEPTH 11.5 FEET ROCK DEPTH 6.5 FEET COVER 5+ FEET NOTE: THIS IS NOT A SURVEYED PLAT. P/ELL & SEPTIC LOCATIONS TAKEN FROM ON-SITE P/A~R ANO P/ASTE WATER OEPARTMENT DOCUMENTATION. ALL LOCATIONS SHOP/N ARE APPROXIMATE. £5 fl £5 50 75 lOO 1c75 150 SCALE: l' = 50 PT, LOT i~ SPURKLAN]) NO, CE.11500 SPURKLAND ENGINEERING 203 W 15TH. AVENUE ANCH. AK. 99501 (907) 279-3916 LOT 13 BLOCK 3 TALUS YEST Chorles Mose/ey 1866 WILDERNESS DRIVE, ANCHORAGE, AK 99516 ILSEPTIC SYSTEM DESIGN DATE: AUG. 4, 2011 SHEET: 2/3 GRID: 2756 PERMIT # IISPllllXX PID # 015-201-42 TALUSWESTBSL1SCSO. DI,/G To Exist:ing Drain Fie/cl Shallow Trench; . O0 0 0 0 2' Wide ~ ~ Exi~in~ 1500 ~al Septic ~ank 80' Lon~ ~ ~.5' Max Deep ~ 6.5' Se~er Rock ~ ~ 5' Cover ~ ~ ND SCALE ~. L Monior Oeonout~ 5' Cover D/ t Barrier "~l Effective Existing ~500 goL sepfic ~onk 6,5 ?~ o? Septic Rock NO SCALE SPURKLAN~ ENGiNEERiNG ~US ~S~ B~ 3 ~0~ ~3 SEPTIC SYSTE, 9ES~GN ~03 ~5~h Ave Anchorage Ak 9950~ CHARLES ~OSELEY 9ATE, AUGUST 5, PER, If ~ OSPXXXXXX PARCEL ID ~ 015-201-42 TALUS~ESfBSL15DS. D~G Performed For: Legal Description: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.ci.anchoraqe.ak.us (907) 343-7904 Soils Log - Percolation Test i.~ Township, Range, Section: Slope Site Plan ! 4- 5- 6- 8- 11- 12- 13- 14- 17- 18- 19- 20- COMMENTS WAS GROUND WATER z/ ,/V~ ENCOUNTERED? S IF YES, AT WHAT DEPTH? O Depth to Water After p Monitoring? ~'P-7' E Date: ~J6JJ~ Reading Date Gross Time Net Time Depth to Water Net Drop j / ~1:05" . ,, ~. PERCOLATION RATE ._ : ~ . (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~ FT AND ~ FT CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WiTH ALL STATE AND MUNICIPAL ~-01D~L/INES IN EFFECT ON THIS DATE. DATE: Environmental Consulting and Design Single Family On-site Wastewater Disposal System Construction and Material Specifications Subject Property: Talus West Block 3 Lot 13 Date: August 5, 2011 General: m The owner shall contract with a contractor to perform the work outlined in these specifications and plans in accordance with the attached MOA permit. There is not contractual arrangement between the contractor and the Engineer. The Engineer shall be the owner's representative and will inspect the work to document the contractors activities. Final acceptance of the contractors work rests with the owner and the MOA. The scope of the project includes the procurement and installation of a 4-bedroom on- site wastewater disposal system at the location depicted on the attached site plan drawings. The drain field is comprised of 1 trench, 2-feet wide, 80 feet long, with a maximum depth of 11.5 feet, with 6.5 feet of septic rock below the distribution piping. All components of the proposed septic system must be constructed a minimum of 100 feet from any surface water or water wells in the area. A minimum of 4 feet of earthen cover is required over the septic tank and a minimum of two feet of cover is required over the drain field. Tn addition to the required earthen cover, 2-inch thick, 40 psi, direct bury board foam shall be installed directly over all installed piping. Construction shall be in accordance with the approved site plan and design drawings and any special provisions noted on the Municipal well and/or septic permit. All materials, components, workmanship and construction practices shall comply with the Municipality of Anchorage's latest ordinances regarding wells and septic systems, as well as MOA, Development Services Department, On-site Water and Wastewater Program (DSD) policies. The contractor is responsible for obtaining all underground utility locates, layout of the proposed system, and verifying and maintaining all required separation distances to lot lines, surface water, wells, steep slopes, etc. The property owner shall be responsible for final grading any depressions formed from settlement of backfill material. The property owner is also responsible for vegetation of all areas disturbed by septic system installation activities. Contractors installing wastewater disposal systems must be certified to do so by the MOA DSD, On-site Water Wastewater Program. Property owners installing their own systems must receive advanced approval from MOA DSD prior to system installation activities. The contractor shall ensure that ALL materials being used are in compliance with the most current guidelines established by the Municipality of Anchorage. Refer to "Standards and Specifications for Component Parts and Materials Used in the Construction of On-site Wastewater Disposal Systems", Dated December 2000, as provided by MOA DSD, On-site Water and Wastewater Program. 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland~gci. net Environmental Consulting and Design Drain field Construction: 9. 10. Znspections: The drain field shall be excavated to the dimensions outlined in the design drawings. Tf any discrepancies are noted, contact the engineer immediately for clarification. The drain field shall be installed parallel to slope contours. The bottom of the drain field shall be within 2" of level. [f the sidewalls or bottom of the excavation become smeared, they must be raked or scarified prior to the placement of filter sand or drain rock. The drain field must be a minimum of 5 feet from the test hole excavation. Distribution pipe is to be installed level with perforations facing downward, atop a level bed of drain field rock. Septic rock shall then be placed atop the distribution piping to provide a minimum of 2" of cover, level across the entire width and length of the trench, above the piping. A silt barrier must be installed at between the final drain rock and the native soil backfill. The silt barrier shall cover the entire drain rock surface. Monitor tubes must be 4" in diameter, installed in the locations depicted on the design drawings, and extend a minimum of 12" above final grade. The portion of the monitoring tube below the septic rock must be perforated and the portion above the drain rock shall be solid. Backfill over the final gravel layer must not be less than 2 feet. Insulation must be installed when the backfill depth is less than 3 feet. Drain field back fill shall be mounded to prevent depressions from forming due to subsequent settlement of backfill material. The contractor shall verify that the drain field is a minimum of 100 feet from any residential water well, 150' from any class 'C' well and 200 feet from any community water wells. Additional separation distances must also be maintained. A minimum of two inspections are required by the Municipality of Anchorage. These inspections must be conducted under the supervision of a Professional Engineer licensed to practice in the State of Alaska. The first inspection must be conducted after the excavation of the drain field and before the placement of any gravel. The septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, stand pipes, cleanouts, and insulation, but before the placement of any backfill. The contractor shall provide a legible copy of all field notes relating to system layout and construction to the engineer for the use in preparing the record drawings. The contractor shall coordinate all inspections with the Engineer. A minimum of 24 hours notice is required prior to the start of construction. ]:f necessary, a preconstruction meeting will be held on-site. 203 West 15th Avenue Suite 203, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland~gci.net Municipality of Anchorage .'::: ' Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 S. Bragaw St. ~ .-./" P.O. Box196650 Anchorage, AK 99519-6650 Page [ of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: 5'~.,, o¥ oD / ? PID Number. ~/.~-- E:o/- 6,?_ Name i~/"h I"/o.r~z{~/, WastewaterSystem: I-'1 New [] Upgrade Address II ~ (( to't/,c/'er',~e.r.r Or,;vet Ancl~ 9eD'"/4' ABSORPTION FIELD Phone Number of Bedrooms: "~ ¥,~-- __? ~ ¥ y ~ I'l Deep Trench [] Shallow Trench [] Bed [] Mound r'l Other. $o~1 Rating: Total Depth from original grade. LEGAL DESCRIPTION ,,~,,¢ ~,. Bloc. lc Lot: Subdivision: Depth to p~pe bottom fr~m original grade: Gravel depth benaat~ pipe: ~ I -~ "~C:3'/L(J' ~"/~-~' J Ft. Ft. Township' Range: Section: F~ added abd~e c~ginal ~ade: Gravel Length: Ft. FI. Well: EX/J/' [] New [] Upgrade Orav.~,,~ FL .umberoflines: I Oistancabetweenlines:Ft. Class,fication (Pnvate. A. e. C): Total Depth: Cased lo: Total abeD(priori area: Pipe Material: Static Water Loyal: Installer. ~. "/"/t- A/)c',,) Dale Installed: Onl[e~ Date Drilled: YmldGPM IP"mp set=~ Ft. [ Cas,, He~U,~ov. C-~r~=r. TANK SEPARATION DISTANCES [] septic [] Holding [] S.T.E.P. [] Other:'  Manufacturer. Capa¢=ty:. To Septic Absorption Lift Holding Public/Private Tank Field Station Tank Sewer Line /~,n r./-) ~ r'o~' "J-~o ~/ / ..5""~'&2 Gal. Material:~' Number o1' Compar[menls: [o,S~'a~Wa'erUne '> ttoo'..','' '> ttr-'c"C' --_ -.- ~~'~ s,=: oal.ua~,a~re~LIFT STATION N.g. Pump Make & Model Electrical Inspections perfocmed by:. Curtarn Drain ~ -- ~ Remarks 0,,.~,,.,o! Se~,c ~L~ p~,.p~..r, BENCH MARK ' Locauon and Description: Assumed EleVatlOi'l: Engineer's Stamp Inspections performed by: Flot'/~? T, c4 .C~,¢. Dates: 1st ~-./l~;~/"~C:~Y ~'("O'.",qnm~'~_~¢'~"~ %~.. Development Services Department Approval Reviewed and approved by: t,~''J'~ Date: z//J?//~ ~,~.',% CE-358~ . , ... PERMIT NO: SWO40019 PID NO: 015-201-42 SWING TIES: FROM: COR. "A" TO: FDN. C.O. "C" 30.5' S.T.C.O. "D" 43.5' S.T.C.O. "E" 49' DBL. C.O. "F" 50' PIT C.O. "G" 45.5' COR. "B" PAGE 2 OF 2 ......... . · 14.2' ,' 23.5' ,' 48.5' /" " "'R 100' ! LOT t3, BLOCK 3 TALUS WEST SlD INV. 94.1' 4' SOIL COVER PROFILE VIEW SCALE: 1" = 5' INV. 94.3' LOT 13, BLOCK 3, TALUS WEST SID SEPTIC TANK REPLACEMENT AS-BUILT INSPECTION REPORT FLATTOP TECHNICAL SERVICES SCALE: AS NOTED 14530 ECIIO STREET DRAWN BY TFM ANCHORAGE, ALASKA 995 ! 6 FEBRUARY, 2004 MUNICIPALITY OF ANCHORAGE Deve/oprnent Services Department . On-Site Water & Wastewater Program 4700 South Brogaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Feb 13, 2004 Expiration Date: Feb 12, 2005 Permit Number: SW040019 Legal Description:/TALUS'WEST BLK' ~3 LT ;13 ~ Design Engineer: 0019 Flattop Technical Services Owner Name: RUTH MOSELEY Owner Address: 11866 WILDERNESS DR ANCHORAGE, AK 99516-2234 Parcel ID: 015-201-42 Site Address: 011866 WILDERNESS DR Lot Size: 19318 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [~ Septic Tank Holding Tank [-"1 Privy [] Private Well Water Storage All construction must be in accordance With: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received Date: ?--/' /3/~'~,' Date: MUnicipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. ~T t .~"- ~ o t - ¥ ~. Permit Number SW~40~ ! ~ Property owner(s) Mailing address (1) Mailing address (2) I Day phone Zip Code 9 9.,~"v'¢ Legal description (Lot, Block & Sub'd.) Legal description (Section, Township & Range) Lot Size /~ ~.IB THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool Acre~~ Number of Bedrooms /7" Well Only Water Storage ~o Ll/ap~' e~t~ Jacu~i Water Softening Unit I certify that the above information is correct. I further cedify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Receipt Number: (Rev, 12/00) Waiver Fees: Date of Payment: Receipt Number: CIVIL & ENVIRONMENTAL ENGINEERING · ENERGY CONSERVATION & ANALYSIS TItEODORE F. MOORE, P.E. PH: (907) 345-1355 M.O.A. DSD P'.O/Box 19-6650 Anchorage, AK 99519 February 13, 2004 14530 ECHO ST. ANCHORAGE, ALASKA 99516 Dear Sirs: The purpose of this letter is to provide the required design narrative in supPort of our application for a permit to replace a collapsed septic tank on Lot 13, Block 3, Talus West S/D, located at 11866 Wilderness Drive. A site plan and specifications are enclosed for your review. The original 32-year old tank has just collapsed so we are requesting an emergency replacement permit in order to install a new tank. Although the residence is 4-bedroom, the owners wish to install a 1500-gallon, Municipally approved septic tank. The topography of the lot in the area of proposed construction is generally level. The proposed project will have no significant impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any significant impact on reserved space-surface and subsurface, or on drainage. Please give me a call at 345-1355 if you have any questions on this submittal. Sincerely, Ted Moore, P.E. INSTALL DBL. C.O. WELL \ SEPTIC AREA \ ABANDON '\ RIETAIN ~ COLLAPSED LOT 14, BLOCK 3 EXISTING -- ~ SEPTIC TAN~ WELL TALUS WEST ~ ~ R 100' SEEPAGE PIT R ........... LOT 13, BLOCK 3 "., TALUS WEST SID , ' LOT 21, BLOCK 3 ·, LOT 12, BLOCK 3 TALUS WEST #1 ", ', TALUS WEST " " SYSTEM SEPTIC AREA ~~"'-' ~ ~.' LOT 13, BLOCK 3, TALUS WEST SID SEPTIC TANK REPLACEMENT SITE PLAN FLATTOP TECIINICAL SERVICES 1 INCH = 40 FEET 14530 ECItO STREET DRAWN BY TFM ANCIIORAGE, ALASKA 99516 FEBRUARY, 2004 NOTE: THIS IS NOT A SURVEYED PLAT. ALL LOCATIONS SHOWN ARE APPROXIMATE. G&ttop Tec~nbzalSenzbres 14530 Bc~o Street, Anchorage, AK 99516 Phone (907) 345-1355 Lot 13, Block 3, Talus West S/D 11866 Wilderness Drive Wastewater disposal system installation Specifications 1.0 General: 1.1 The scope of the project consists of properly abandoning the existing collapsed 1250-gallon septic tank and replacing it with a new 1500-gallon Municipally approved septic tank. 1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor deviations from these drawings may be allowed or required by the engineer conducting the inspections. Ail construction procedures and material specifications shall conform to Municipal and State requirements. All separation distances shall be in conformance with Municipal requirements, unless specifically waived. 1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any buried utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is achieved after settlement and that there are no residual depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the construction. 2.0 Septic Tank: 2.1 The existing septic tank must be properly abandoned by thoroughly pumping, removing the top and backfilling with soil. 2.2 The new 1500-gallon, 2 compartment septic tank shall be Municipally approved and shall be set level on undisturbed soil. Each compartment shall be equipped with a watertight manhole cover and a 4" cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial type, rigid insulation. 2.3 The discharge line from the new tank shall be plumbed into the existing seepage pit. All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The waste line from the residence to the septic tank shall have a minimum slope of 1/4'" per foot, and the waste line between the tank and the soil absorption system shall have a minimum slope of 1/8" per foot. A c.o. shall be installed 1 - 4 feet from the building foundation, and a double c.o. shall be installed within 5 feet downstream of the septic tank. 3.0 Inspection: 3.1 The septic tank requires one inspection after it is set level and the piping connected, but prior to backfill. G~ '~ER ANCHORAGE AREA BORO[ D~c'~RTMENT OF ENVIRONMENTAL 0UALi,-,~: 3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 279-8686 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM MAILING ,~.. ADDRESS ~%~C~ '~ LEGAL DESCRIPTION L(¥~ PHONE SEPTIC TANK: DISTANCE FROM WELL LIQUID CAPACITY GALLONS. MATERIAL ,~/'~/'~ ~-J~¢~'~.~ NUMBER OF . _COMPARTMENTS Ill il: t61~(~', ~ INSIDE LENGTH ~ INSIDE WIDIH ~'- LIQUID DEPTH. SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS LINING MATERIAL~:~ NEAREST LOT LINE. OUTSIDE DIAMETER OR WIDTH _~)2 ¢~ ,~ LENGTH /~ 72~' ~?DEPTH (~.X~'!,~L¥--~ ~lli.)~],? DISTANCE FROM WELL /~LS' / BUILDING FOUNDATION TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ' ~ ~z~[ SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL NUMBER OF LINES ABSORPTION AREA DEPTh TOP OF TILE TO FINISH GRADE DISTANC~..~E~EEN LINES TRENCH WIDTH // SQ. FL .ENGTH OF EACH UNE DEPTH OF FILTER MATERIAL BENEATH TILE TOTAL LENGTH , OF LINES N. TOTAL EFFECTIVE IN. ABOVE TILF DISTANCE FROM WELL: TYPE//c)I)i~, i')~l~/~-~A DEPTH '~1 , BUILDING EOUNDATION.__t~E/ ~ NEAREST SEPTIC " SEEPAGE LOT LINE ~J~ SEWER LINE. ~ _, TANK '?~' '/~ SYSTEM WATER . CESSPOOL . NEAREST OTHER ~ . SOURCES DISTAF, CES: DIAGRAM OF SYSTEM t~y~S ~,' Z,e~I 140~.~d G.A.A.B. DATE 9~j ia.,/~272- GRE/~,~,,E,R,-- ANCHORAGE AREA DEP^.TME.T O. ENV,RONMENT*L °UAL,TV PER"IT "O. 3500 TUDOR ROAD POUCH 6-650 ANCHORAGE. ALASKA 99502 TELEPHONE 279-8686 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT INSTALLATION OF: SEPTIC TANK ¢¢' SEEPAGE PET / , DRAIN FIELD OTHE~ FINANCED THROUGH ' TO BE ~NSTALLED BY SOIL TEST .ESULTS '-~¢// /¢ / ~ NOTE, THIS PERMIT IS NOT VALID WITHOUT SOIL TEST SEPTIC TANK , SEEPAGE PIT "~;~ -, DRAIN F]ELD WELL TO SEPTIC TaNK f~ , SEEPAGE Pit WATER main TO SEPTIC TANK ~/~/~.i J SEEPAge PIT DRAIN F]ELD TO RIVEr, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 feet INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST lEON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL ~.:;'.~ CONFORM TO BOROUGH BEC;fJLATIONS REGARBING INSTALLATION, - CH eALTKAU~HORITY~ OR LIOENSED DESIGNER I CERTIFY THAT [ AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE ARR/~A'~OROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE ElaTE '~ APPLICANT'S SIGNATURE Well Owner'! < M-W DRILLING, DRILLING LOG Location (address of: Township, Range, Section, if known; or distance main road Size of casing static water level Screen ( .Depth of Hole 75 ft. i~e) ); Perforated ( I./!.~ feet Cased to i!.4[]. 7 feet (below) land surface. Finish of we11 (check one) ). Describe screen or perforation Well pumping test at 'J gallons per of drawdown from static level open end ( ~ ); (minute) for ')- hours with Date of completion 6 / 6 / / 7 WELL LOG Depth in feet from ground surface Give details of formations penetrated, size of materiaI, color and hardness TO TO __TO j (I TO J. 2 __TO ' <'~' TO 3 ') TO '/'% TO ii 00 TO~ ~'~ TO_ .12.) TO_ TO_ TO_ NWWA Cer6fi, ed Contractor ~]ert~irrate Nos. 814 ~ 973 2 ~ STATE