ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP111267 PID Number: 015-202-59 ❑ New 0 Upgrade
Name:
Dennis J. Smith
ABSORPTION FIELD
❑ Deep Trench Ilow Trench �r Bed ❑ Mound
Address
11670 Wilderness Drive Anchorage, AK 99516
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
3
05 -y GPD/SF
2-3 FL
LEGAL DESCRIPTION
Depth to pipe invert from original grade
+.5 Ft.
Gravel depth beneath pipe
.5 Ft.
Subdivision Block Lot
Talus West No. 2 6 2
Fill added above original grade
4.5 Ft.
Gravel length
60 Ft.
Township Range Section
Gravel width
15Ft.
Beds: Number of Lines
3
Distance between lines
5Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Lift Station
Tank
Line
900 Ftp
Ft.
well
>100'
>100'
N/A
N/A
>25'
TANK ❑ Septic ❑ S.T.E.P. ❑ Holding [ Other
Manufacturer
AnchorageTank/Orenco
Capacity
1,500G,I.
Surface water
>100'
>100'
N/A
N/A
Material
Steel
Number of compartments
Two
Lot Line
>5'
>10'
N/A
N/A
NA
Foundation
>5'
>10'
N/A
N/A
LIFT STATION
Manufacturer
Orenco
Capacity
62.9"Gal.
!
Curtain Drain
I None
Noted
Pump on level at
Pump off level at
High water alarm at
RemarksExisting Holding Tank Decommissioned in
32 in.
22 in.
36 in.
Accordance with Municipal Code.
`Pump Vault Volume Based on Pump On Level.
Pump make and model
PVU68-2425-L
Electrical Inspections performed by
Municipality of Anchorage
PIPE MATERIAL Housetotank D3034 Tankto D3034
drainfeld
Installer
PCN, Inc.
Drainfeld HDPE CO/MT D3034
Inspector AH
BENCHMARK (Assumed elevation) 100.0ft
Inspection
10/24/11 a 10/25/11
Location and description
dates: 2
3i0 10/26/11 4'"
Garage Slab.
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
��,
•••••••
• qs
-'�'eSillAir
Conditional Approval: DateTH
fid: • • •,ry�j
s
00.... •••. .i.. .. N.
/
N. N NN( .NY.�. s.N •N
�MICHAR E ANIMSON :0 --
0CE - 4381 •`g
CE
o'
�I�tyfp�..... ..•�+U4
�i�t�%
Approved Date /) j//
����'
Inspection Report 44-12.doc
TALUS WEST SUBDIVISION NO. 2
SITE PLAN
SCALE 1" = 30'
Permit No.. OSPI11267
PID No. 015-262-59
Page 2 of 3
wl
0
fJ)
0
Ld
Z
Of
of
J i
WLI).: 79
49th
�............... .Cr , ice
01 %MICHAEL E. ANDERSON ? L
LOT 2, BLOCK 6
I
N75.26, 39,538 S.F.
os W
'8s.6s
I
I
/
I
I
I
/
/
I
I
I
LEGEND
I
I
MT — Monitor Tube
I
FCO — Foundation Clean Out Existing Well
I
TH — Test Hole
CO — Clean Out
v I
I
MH — Man Hole
u
PV — Pump Vault
0
w
of
1a
�I
o I
Existing Holding Tank System
\
IS
Abandoned Per Municipal Code.
I
�I
0
NI
I
A
B \
S1
10.7'
52.0'
MH
18.0'
54.2'
I
PV
19.3'
62.6'
I
M1
55.8'
30.5'
\
\ Three Bedroom
I
I
M2
41.4'
68.5'
\ Home
A p
I
I
FCO
I
P V S1
I
k0 MH
LTH2 J*
15'Wx 60'L
___
Absorption Bed
L— (D J
----
TFn
I
M2
I
L---------------------------------
_________________nt--___
5'
_5' Street Light Easement
SITE PLAN
SCALE 1" = 30'
Permit No.. OSPI11267
PID No. 015-262-59
Page 2 of 3
wl
0
fJ)
0
Ld
Z
Of
of
J i
WLI).: 79
49th
�............... .Cr , ice
01 %MICHAEL E. ANDERSON ? L
Permit No.: OSP111267
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Page 3 of 3
PID No. 015-202-59
102.9 a 102.9
Groundwater @93.7' 9-19-11
Scale: NONE
49th
AEL E. ANDERSON
No. CE -4361
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP111267
Tax Code Number: 01520259000
Work Type: Septic Upgrade
Permit Effective Dates: October 19, 2011 to October 18, 2012
Design Engineer: ANDERSON ENGINEERING
Subdivision: TALUS WEST #2
Site Legal Address: TALUS WEST #2 BILK 6 LT 2 G:2736
Owner/Address: SMITH DENNIS J
2906 W 30TH AVE SPC 7 ANCHORAGE AK 995171727
Site Mailing Address: 11670 WILDERNESS DR, Anchorage Lot Size in Sq Ft:
Total Bedrooms:
This permit is for the construction of:
39538
3
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received B,
Issued By:
f CF Zo — /r
Municipality of Anchorage
P.O. Box 196650 •4700 Elmore Road
Anchorage, Alaska 99519-6650 * (907) 343-7904 s Fax (907) 343-7997
11 hftp://www.muni.org/Onsite
Development Services Department
Ori -Site Water and,Wastewater Program
a� t.
Department
* * * * VARIANCE/WAIVER REVIEW * * * *
WR#: OSP111305 HAM Permit#:OSP111267
PID#: 015-202-59
Legal Description: Talus West #2. Block 6. Lot 2
Engineer: Anderson Engineering
Applicant: Dennis Smith
Your request for a waiver of the requirement for the absorption field to be parallel with the slope
contours has been approved.
This waiver approval applies to the existing absorption field only. Any future upgrade to the on-
site wastewater disposal system will require all separation distances be met or another approval
from this department.
Waiver is Granted: X Waiver is not Granted:
Date: 10/19/11 Approved by
Nameof Reviewer
Rec#: 07612G Amount: $200.00 Date Paid: 10/19/11
**** VARIANCE/WAIVER REVIEW ****
MUNICIPALITY OF
Community Development Department Phone: 907-343-7904
Development o — 907-343-7997
On -Site Water & Wastewater Program
Mayor Dan Suffivan
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. C✓/'5= Z,0Z — T7
Property owner(s) Dat ii jo,J >> Phi°"irw Day phone
Mailing address & �l" i ---K-4 ESS Nwr AmcxIoLA e k
Site address
5.
Legal description (Sub'd., Block & Lot)
t.jr e—
Legal description (Township, Range & Section)
Lot Size 3 T ?L Sq. Ft. Number of Bedrooms
THIS APPLICATION IS FOR: THIS APPLICATION IS AN:
(® all that apply)
Absorption Field Initial El
Upgrade
Septic Tank
%
Holding Tank ❑ Renewal ❑
Privy ❑
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
c
P(
r/
/Rush Fees: l Waiver Fees: C) 0 �
Date of Payment: i Date of Payment:
Receipt Number: Receipt Number: }
Permit No. O`:)'i Waiver No.
GABuilding\On Site\Forms\Client Forms\Permit App_01 041 1.doc (Rev. 1/11)
ANDERSON ENGINEERING
P.O. BOX 240773`
ANCHORAGE, AK 99524
522-7773 677-7766 FAX
October 11, 2011
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 2, Block 6, Talus West Subdivision No. 2
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 2, Block 6, Talus West Subdivision No. 2 intends to decommission the
existing holding tank system on the lot and construct a new septic system to serve the
three-bedroom home on the lot. We are therefore requesting a permit be issued for a
septic system to serve the existing home. The available area for the septic system is
limited by the presence of a well close to the southern lot line and the existing well on
the lot. In addition soil conditions on the lot indicate slow percolation rates and
groundwater elevations close to the surface which make it difficult to place a
conventional septic system. We therefore propose to place an Advantex Treatment
System on the lot to provide the most effective treatment of the septic effluent prior to
discharge into the surrounding soil strata. The location of the absorption system is
shown on the attached Site Plan. Drainage patterns are also shown on the plan and
will be modified somewhat as a result of the proposed construction. The existing
holding tank system will decommissioned in accordance with Municipal Code.
The test holes placed on this lot revealed silt with some sand and gravel. The
percolation rate in the materials encountered was between 60 and 120 minutes per
inch. Groundwater was found at 5.2' below the surface during the monitoring period.
Our design provides for the bottom of the absorption bed to be at the surface of the
existing ground. We are proposing to place a four-bedroom Advantex Treatment
System. The absorption bed will be 60' long x 15' wide for a total of 900 square feet of
absorption area. The distribution line in the bed will be placed at the existing ground
level. 2' of fill and 2" of insulation will be placed above the bed and 4' over the septic
tank to meet Municipal Code and prevent freezing. The side slopes of the mound will
be at 4:1 and extensive landscaping and fill will be required to insure positive drainage
away from the finished mound.
Lot 2, Block 6, Talus West Subdivision No. 2
October 11, 2011
Page Two
An absorption bed was placed on the lot in 1984 near the location where the proposed
bed will be constructed. All remnants of the old bed within the perimeter of the new bed
will be removed prior to construction. We do not anticipate the presence of biological
matting after nearly 30 years of non use. In addition, the file for the lot indicates a
French drain was once proposed to be placed along the eastern lot line. No evidence
of drain construction could be found either in the file or on the property.
The ground surface of the lot slopes to the west at a slight slope. The bed cannot be
constructed totally parallel with the contours of the slope due to the limited space
available. A waiver request is attached to allow the bed to be constructed slightly out of
parallel. All components of the new septic system will be constructed a minimum of
100' from any surface water and 100' from the well proposed for this lot. No conflicts
exist between the proposed well and septic system and those in the area.
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
1•,bC�`7
Michael E. Anderson, P.E.
Attachments
.............. tis'p
49th•••••••
MICHAEL E. ANDERSON
NO. CE -4381
♦� �� ROFESS\0 �i�i
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 FAX
October 11, 2011
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 2, Block 6, Talus West Subdivision No. 2
Absorption Be to Slope Contour Waiver
Dear Onsite Services Engineer:
The subject lot has limited surface area for construction of a septic system upgrade due
to the location of the well and the presence of tight soils. The proposed bed has been
located in the most optimal location possible and will be 60' long and out of parallel with
the contours. The area identified for bed placement will be leveled prior to construction
of the new bed with clean granular gravel meeting the specification for Type !!A Select
Fill. The absorption area of the bed will remain in the soils verified suitable by the
percolation tests and test holes. The Site Plan showing the location of the bed and the
soils encountered on the lot is attached for your review. We hereby request a waiver be
issued allowing the absorption bed to be placed other than parallel to the existing
ground contours.
Sincerely, p
*1"L e
Michael E. Anderson, P.E.
11
10 9
pASSAGE
-
-FIRNLINE
21
Eaa111g Wel
I' IE.46.9 1_ Emlig ..11
----------------------- ---------------
- - - - - - - - - - - - - - - - - -
18
Lu
<
0 19
Ld
w LL)
0utl z
ui
bi I I0
-------------------------
SUNSTONE CIRCLE
- — - — - — - — - — - — -
E.41;.g Wee
12 13
W
•
OF
. .............
VE V`
11
AV
49th
0 W� ud4,.q
0 ............................................
t�, *.MICHAEL E. ANDERSON
AREA MAP
-. % No. CE -4381 All
'j -e!•''
..... 4W SCALE I" = 100'
.....
*4fjv,w4vj ESS�
NOTE:
Reconstruct TH1 & TH2 to Match
Characteristics of Existing Ground
Prior to Construction of Absorption
Bed. Remove All Remnants Old SITE PLAN
Absorption Bed Prior to Construction.
SCALE 1" = 30'
a
N0. 2
OF
�. 49th
..�:... ..... ....... ...........
...................................:.. ::
;MICHAEL E. ANDERSON
No. CE -4381 ti AlF
=!
••���apROFESS1t ls- 4
TALUS
WEST SUBDIVISION
' '
I I
I
I
LOT 2, BLOCK 6
I I
I
10 5'2s
39,538 S.F.
pg..w
/
189.69
I I
I
II
I
II
I
I
I
LEGEND
I I
I
I MT — Monitor Tube
I I
I
FCO — Foundation Clean
Out Existing well
I I
I
TH — Test Hole
I I
I
CO — Clean Out
MH — Man Hole
N I
LS — Lift Station
I I
I I
WI
of
I
I
cc I
II
-a
c
°
\
I IE
Iy
I
O
\
W
al
0
I to
I
II
I
LU
I
I
O I
Z I I
I
\
Three Bedroom
I I
II
I
I
—_Home
I I
I
FCO
(Three Bedroom Advantex
Treatment System with MH Existing Holdingq Tank System
y
with
AX20 Pod and Add On
Abandon
Per Munici al Code.
p
I
LS
I Lift Station. 15' Wide x 60 0 0
I I
II
I Long
I
Absorption Bed.
II
I
TH2-----------
I
I
L_------
® ---J
4%
Abandoned 1986
Absorption Bed.
I I
I
(Exact Limits Unknown)
IIL---------------------------------
5' Street Light Easement
N89'56 20"E 171.23
NOTE:
Reconstruct TH1 & TH2 to Match
Characteristics of Existing Ground
Prior to Construction of Absorption
Bed. Remove All Remnants Old SITE PLAN
Absorption Bed Prior to Construction.
SCALE 1" = 30'
a
N0. 2
OF
�. 49th
..�:... ..... ....... ...........
...................................:.. ::
;MICHAEL E. ANDERSON
No. CE -4381 ti AlF
=!
••���apROFESS1t ls- 4
LOT 2, BLOCK 6, TALUS WEST
SUBDIVISION NO. 2
DESIGN FACTORS: SYSTEM REQUIREMENTS:
3 Bedroom Home Raised Bed System
Perc. Rate: 120 Min./Inch 4 Bedroom Advantex Treatment System
Application Rate: .5 GPD/SF 500 Gallon Add On Lift Station
Raised Bed Absorption System
3 Bedrooms X 150 GPD/.5 GPD/SF = 900 SF Absorption Area
900 SF/15 SF (Width) = 60 LF Bed Length
THEREFORE: Construct a Raised Bed 60' Long x 15' Wide as Shown Below.
Place Distribution Piping at Original Ground Surface. Remove Organics and Fill to 2.5'
Below Surface and Place Clean Sand & Gravel to Provide 4' Separation From Groundwater. Place
Insulation and 2' of Cover Over Bed or Mound Over Bed Minimum of 3'. Place 4' of Fill Over Tank.
2
Top 6" of Mound Must Be Topsoiled
and Vegetated to Prevent Erosion.
Natural Backfill
3
r 3 2" Insulation & 2' Cover (Min.) 1
1
.5'
.5'
1" PVC
X Drainfield Rock Existing Ground
Existing Ground Min. 2' Clean Filter Sand -�
3.0'
Level to Within 2' of Bottom of Bed
with Type !!A Select Backfill
In Situ ML Soil
0
TYPICAL BED PROFILE �•••oF•��.,
(NO SCALE) �� •�� • • ••AV
°
NOTE: Grade Area Surrounding Bed to Drain Away. • �`;
Minimum 6' Separation From Bedrock. i ,,,,;; h
,,,,,,, 49t,,,,,, , , „ ,,,,,;;,,
Minimum 4' Separation From Groundwater. ice/
Minimum 100' Separation From Wells in the Area. s'' .... ........:..
Minimum 100' Separation From Surface Water or Streams_ 0� �', Michael E. Anderson
Minimum 10' Separation From Water Service Line. 0 No. CE4381
kW : s;
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650 Anchorage, AK 99507
www. ci.anchorage. ak.us
(907) 343-7904
Soils Log -Percolation Test
F
7 \
^-'*-(ENGINk
® 4918 c
s.. ... N.... •....
MICHAEL E. AMERSON
J�•�. CE -4381 ,•.���.
Performed For: Aviv i�lo fie KK uJ160 Date Performed: Sat, Sept., 10, 2011
Legal Description: Talus West Subdivision,Lot 2, Block 6 Township,
(Feet)
1- _ fi-I l.l.
2- i. 9(',6 -e -M
3-
5-
6-
7-
8-
9-
10-
11-
12-
13-
14-
15-
16-
17-
18-
19 -
WAS GROUND WATER
ENCOUNTERED? NO
S
� IF YES, AT WHAT DEPTH? XXXXXXX L
Depth to Water After/� Z o-
Monitoring? E
E
Date: 9/19/2011
mom
Date
mom MEMO
Net Time
EMN
Net Drop
■■■■■■■■■■.
Reading
--
Date
Grass Time
Net Time
Depth to Water
Net Drop
,C 16
�I
— —_ _ - • — 7 r_ t'tKU MULE DIAMETER (�a
TEST RUN BETWEEN -3 FT AND -3.5' FT —+--
COMMENTS TEST HOLE # 1: Perc Cavity was pre-soaked prior to testing-
PERFORMED BY: A. Harala I CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650 Anchorage, AK 99507
www. ci. anchorage. ak us
(907) 343-7904
w m
OF.000*0
NGINEE 'S
C"
1
•�'����:
49�
�
'319
MICHAIM IPS ANMSON
CE - 4381
•�
Soils Log - Percolation Test to,, ��®\� �,*
Performed For: Date Performed: Sat, Sept., 10, 2011
Legal Description: Talus West Subdivision Lot 2, Block 6 Township, Ra e, Section: --..
Depth
(Feet)
2-
3-/
4- 4M%MI.
0-
11-
12-1 13-
-
10-
11-
12-
13-
14-
15-
16-
17-
18-
19-
20 -
8
14-
15-
16-
17-
18-
19-
20 -
WAS GROUND WATER
ENCOUNTERED? NO
S
IF YES, AT WHAT DEPTH? XXXXXXX L
5T" Depth to Water After D
Monitoring?Q P
.�' E
Date: 9/19/2011
Reading
9
Reading Date Gross Time Net Time Depth to Water Net Drop
�`� • �' s!O �� flri?�r ��31
o V'niAs
K"Te x;15
pr:prn1 Arima -1 • A n
- -- -N (i- rtMl, NULE UTAMETER (Q,•
TEST RUN BETWEEN -3 FT AND-3.5'FT
COMMENTS TEST HOLE # * Perc Cavity was pre-soaked prior to Fe—sting-
\14
esting-
PERFORMED BY: A. Harala CERTIFY
PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
IS TEST WAS
- -- -N (i- rtMl, NULE UTAMETER (Q,•
TEST RUN BETWEEN -3 FT AND-3.5'FT
COMMENTS TEST HOLE # * Perc Cavity was pre-soaked prior to Fe—sting-
\14
esting-
PERFORMED BY: A. Harala CERTIFY
PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
IS TEST WAS
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 2, BLOCK 6, TALUS WEST SUBDIVISION NO. 2
GENERAL:
The scope of this project includes the procurement and placement of a
new Four Bedroom Category III Nitrate Reducing Septic System as
manufactured by Anchorage Tank and Orenco Systems to serve the
proposed home on the lot. The system will be placed at the location
shown on the Site Plan. The new septic system also includes the
construction of a new 60' long X 15' wide absorption bed at the
location also shown on the Site Plan. The distribution line in the bed
will be placed at the existing ground surface. The new system must be
placed a minimum of 100' from the existing well on the lot and those
on adjacent lots and 100' from any surface water located near or on
the lot. The organic and fill material will be removed in the area of the
bed and to a minimum of 2.5' below the surface and replaced with
coarse sand and clean gravel meeting the specification stated herein.
A minimum of 2.5' of sand and clean gravel will be required. 2" of
insulation will be placed atop the completed bed and 2' of fill added.
The upper 6" of the mound must be topsoiled and vegetated to prevent
erosion. The entire raised bed area must then be landscaped to
provide positive drainage away from the area. The existing holding
tank system must be decommissioned in accordance with Municipal
Code.
2. Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
3. The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
4. Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise. Extensive fill and
landscaping will be required to provide a finished surface that provides
positive drainage away from the raised bed area.
5. Contractors installing wastewater disposal systems must be certified
by the Municipal Development Services Department, Building Safety
Division, On -Site Water and Wastewater Program for system
installations. Owners installing their own systems must receive prior
Lot 2, Block 6, Talus West Subdivision No. 2
September 27, 2011
Page 2 of 4
approval from the On -Site Water and Wastewater Program before
beginning system installation.
SEPTIC TANK INSTALLATION
1. The Category III Treatment System must be installed in conformance
with specifications and regulations furnished by the manufacturer. No
variances from the manufacturer's specifications will be allowed
without permission from the manufacturer and Municipal
representatives.
2. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
6. A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the bed shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
5. Contractor shall verify the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
Lot 2, Block 6, Talus West Subdivision No. 2
September 27, 2011
Page 3 of 4
6. Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
8. A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic
tank manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
SAND GRADATION:
1. Sand used to level the new absorption bed must have the following
gradation:
50% Passed the No. 4 Sieve
2% Passed the No. 100 Sieve
1 % Passed the No. 200 Sieve
2. The sand source must be approved prior to use.
Lot 2, Block 6, Talus West Subdivision No. 2
September 27, 2011
Page 4 of 4
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as -built of the completed system.
ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND
REPAIR AGREEMENT
MEMORANDUM OF UNDERSTANDING
BETWEEN MUNICIPALITY OF ANCHORAGE
AND ;_ gz
THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this
�ay of Dt* of 20/, by and between
herein the "OWNER," and the Municipality of Anchorage, herein the
"MUNICIPALITY." In consideration of the mutual covenants contained herein, the
parties to this Memorandum of Understanding agree as follows:
1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality
grants permission to Owner to utilize and operate an Advanced Wastewater
Treatment System (AWWTS), described as S',r Vm-" located
at 10T -Z, ew Chi.. 6 . -� r t'S % •' , Anchorage, Alaska.
2. Definitions.
A. Alteration. Any change to the design or function of an AWWTS that
Includes the installation or removal of any parts, components or pieces not
included in the original construction permit and design. Prior to
performing any alterations to an AWWTS the owner must obtain a
Wastewater Disposal System Construction Permit from the Municipality
pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65.
B. Certificate of On -Site Systems Approval. An approval by the
Municipality of existing water and wastewater disposal systems given at
the time of property sale and title transfer in accordance with AMC 15.65.
These approvals certify that the systems are adequate for the homes that
they support and meet the codes that were in place at the time of system
construction.
C. Damage. Any man-made or natural change in a system that would inhibit
the system from performing as designed.
D. Maintenance and Repair. The scheduled and as needed replacement of
existing parts, components and pieces of an AWWTS that were included in
the original design which would allow the AWWTS to continue to
perform as designed.
E. Permit (Construction) An On -Site Wastewater Disposal System
Construction Permit as defined by AMC 15.65.
F. Permit (Operating) An Advanced Wastewater Treatment System
Operating Permit. An annual permit, issued by the Municipality, that
allows the Owner to operate an AWWTS, upon meeting all the
requirements of this agreement, the conditions of Operating Permit, the
requirements of the On -Site Wastewater System Construction Permit and
all relevant provisions of AMC 15.65
3. Fee. Owner shall pay to Municipality an annual fee of NQ i �`'r
($ .00), payable on or before the issuance of the operating permit and annually
thereafter. The annual fee is due on or before the anniversary date of the approval by the
Municipality of installed system.
4. Term. The term of this Memorandum of Understanding shall be for the life of the
AWWTS.
The term begins on the date of approval by the Municipality of the installed system and
shall continue while the AWWTS system is in use or operational or until the property is
sold or title is transferred by owner and a new certificate of On -Site approval is issued to
the new owner or transferee of the property.
5. Alterations, Installation and Removal of Additional Equipment. Owner agrees
not to make any alterations, removal of parts or additions to the AWWTS without a
Construction Permit from the Municipality.
6. Maintenance and Repairs.
A. Throughout the term of this Memorandum of Understanding, the Owner shall
maintain AWWTS in good repair. In addition, it shall be the responsibility of the
Owner during the term of this Memorandum of Understanding, and any extensions or
renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2)
maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs.
Further, Owner agrees to comply will all applicable ordinance, laws, regulations,
rules and orders for the AWWTS.
B. Owner agrees to provide the Municipality a written schedule of routine
maintenance and repairs which have been performed on the system pursuant to the
terms and conditions contained in the Owner's AWWTS Operating Permit. This
schedule shall be submitted to the Municipality annually upon the renewal of the
permit. The schedule of maintenance and repair contained in the Owner's AWWTS
Operating Permit is:
C. Owner acknowledges that the fine schedule for failing to maintain and repair an
AWWTS are codified in AMC 14.60.
D. Owner agrees that only maintenance, repair personnel certified by the
Municipality will inspect and make any necessary maintenance, repairs or permitted
alterations to the system.
E. Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS upon 24 hours written notice.
F. Owner agrees that any sale or transfer of title of the property will not occur
without a new Certificate of On -Site Systems Approval.
G. Owner agrees that the relevant provisions of the standard specification guidebook
for AWWTS is the governing professional guidelines for the construction,
maintenance and repair of the Owner's AWWTS.
7. Nonwaiver. The failure of either party at any time to enforce a provision of this
Memorandum of Understanding shall in no way constitute a waiver of the provisions,
nor in any way effect the validity of the Memorandum of Understanding or any part
hereof, or the right of such party thereafter to enforce each and every provision
hereof.
8. Amendment.
A. This Memorandum of Understanding shall only be amended, modified or changed
by a writing, executed by authorized representatives of the parties, with the same
formality of this Memorandum of Understanding was executed and such writing shall
be attached to this Memorandum of Understanding as an amendment.
B. For the purposes of any amendment modification or change to the terms and
conditions of this contract, the only authorized representatives of the parties are:
Owner: &eNtl
/'
Anchorage: Purchasing Officer
C. Any attempt to amend, modify, or change this contract by either an
unauthorized representative or unauthorized means shall be void.
9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of
Understanding shall be brought in the Superior Court for the Third Judicial District of the
State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and
obligations of the parties under this Memorandum of Understanding.
10. Severability. Any provisions of this Memorandum of Understanding decreed
invalid by a court of competent jurisdiction shall not invalidate the remaining provisions
of the Memorandum of Understanding.
of �� ♦I�� ��%:�
Date:J iL
STATE OF ALASKA
THIRD JUDICIAL DISTRICT
MUNICIPALITY:
By:
Title:
Date:
ss.
,4C . 1
The foregoing instrument was acknowledged before me this day of (� ,
201-L, by Simon r- ff ,C - /'.7 u -f sFz,, ./1 `T '— -��-
NOTA Y PUBLIC FOR ALASKA
My Commission expires: %r
MUNILAHALI I Y VI- ANCHORAGE
72-013 (3/85)
DE` RTMENT OF HEALTH AND HUMAN SER�.,ZS
Environmental Health Division
825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720
ON-SITE
SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Name Ve M s
�" ��'
DISTANCES
il
TO
3EPi
ABSORPTION
Atltlfe55
FROMWELL
TANK
FIELD
I I Lo
GY 2SS
7
Phone(s)
Permit No. No. of Bedrooms
WELL
bo 1_
:34-s- QW3
I 3
LEGAL DESCPIpTION
LOT LINE
+Lot
Block
G
Subdivision
1 VIl&s1
r+
FOUNDATION
D
Township, Range, Section
S^
L
AS -BUILT DIAGRAM (Show location of well, septic system, property Innes, foundation,
driveway, water bodies, etc.)
TANKS
F1SEPTIC
HOLDING
Manufacturer
Capacity in gallons
C
2ea Qo
Material
No. of Compa��rtJIm-enhi 101
TYPE OF SYSTEM
❑ TRENCH fIr ❑ BED
❑ W. DRAIN ❑ OTHER.
Depth to pipe bottom from
Total depth from original grade
original grade
FT
FT
Fill added above original grade
Gravel depth beneath pipe
FT
FT
Gravel length
Gravel width
FT
FT
Total absorption area
Distance between lines
h
SQ FT
FT
Number of lines
Soil rating
Pipe material
SQ FT
Installer
Date Installed
WELLS
❑ PRIVATE
❑ OTHER (Identifv)
f e
e. -
k -1 -Classification (A,B,C)
Total Depth
Cased to
FT
FT
Installer
Date Installed.
0.
REMARKS:
a'le
1
Scale:
EVgNEESRS SEAL
o a,
Inspections P rfa metl by:
U�
1 sl �S
r
£
Ir �
Date-
I e
aqP Ilia This in cfion was performed according to all
6' a G-, = ♦J"
ti
Municipal and Slate guidelines in effect on this dale::
'y
7
Health Department Approval:
f"""_—'„�— �`�^'t'`"�-� Date. a-
72-013 (3/85)
Department �,) Health and Environmental, rotection
825 is Street, Anchorage, AK. %1301
264-4720
Permit # # # # HANDWRITTEN PERMIT # # #
WELLfi1/OR ON-SITE SEWER PERMIT
Applicant: �Y/J��o--���� Mailing Address: 70 -7 7 O S 9�Syz
Location:
Phone Number:
_y7/
Legal Description: t__ 6�- a <P 'J&14_t0 `6j Lot Size: --
Type of Soil Absorption System Is:
Trench: Drainfield: Seepage Bed: Holding Tank: 'I
Maximum Number of Bedrooms: Soil Rating(sq.ft/br) r 336
i
The Required Size of the Soil Absorption System Is:
DEPTH LENGTH GRAVEL DEPTH
WIDTH
The length dimension is the length(in feet) of the trench or drainfield. The
depth of a trench or pit is the distance between the surface of the ground and
the bottom of the excavation(in feet). There is no set width for trenches.
The gravel depth is the minimum depth of gravel between the outfall pipe and
the bottom of the excavation(in feet).
# # REQUIRED SEPT-I-C(HOLDING) TANK SIZE _ © GALLONS # #
Permit applicant has the responsibility to inform this department during the
installation inspections of any wells adjacent to this property and the number
of residences that the well will serve.
* # * TWO(Z) INSPECTIONS ARE REQUIRED * *
Backfilling of any system without final inspection.and approval by this department
will be subject to prosecution.
Minimum distance between a well and any on-site sewage disposal system is 100 feet
for a private well or 150 to 200 feet from a public well depending upon the type
of public well. Minimum distance from a private well to a private sewer line
is 25 feet and to a community sewer line is 75 feet. Well logs are required
and must be returned to this department within 30 days of the well completion.
Other requirements may apply. Specifications and construction diagrams are
available to insure proper installation.
# # #PERMIT EXPIRES DECEMBER 31, 1 9 3 3
I certify that:
(1) I am familiar with the requirements for on-site sewers and wells as
set forth by the Municipality of Anchorage.
(2) I will install the system in accordance with codes.
(3) I understand that the on-site sewer system may require enlargement if
the res denc is remodeled to include more tha bedroom .
Signed: Issued by
:�
Applicant ��
Date/Q
1
SWP/024(1/81)
r (
ALASKA 6-dROWnTAL COnTROL RkolCCS, Inc.
Engincerinq 6 Enuironmental Studies
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: D`.f 76 r,/ F / ' - DATE PERFORMED:G-
LEGAL DESCRIPTION: &
DEPTH SLOPE SITE PLAN
FEET)
1
2
z.
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
18
20
S• H (ML
C. Reid,
.2251-6
a
WAS GROUND WATER U0
ENCOUNTERED?
IF YES, AT WHAT
DEPTH? _
■■■■■■■■■■
Reading
Date
Gross
Time
Net
Time
Depthae 0�1
Water /{j?
©sfii
®
�z
/f�;3J
D•b�
■■MEN
c c,..' 7v
SCnc //7
—0;6 ?'/
NEENN
oa la (JCS
IC zy'F
✓c.� iJF
ci fL a.,
plr
9/8•(Y
■mmom
=MMMT
■■■■■■■■■■
Reading
Date
Gross
Time
Net
Time
Depthae 0�1
Water /{j?
Net
Drop lj)
®
�z
/f�;3J
D•b�
c c,..' 7v
SCnc //7
—0;6 ?'/
oa la (JCS
IC zy'F
✓c.� iJF
ci fL a.,
plr
9/8•(Y
PERCOLATION RATE (minutes/inch)
? 'l
TEST RUN BETWEEN 2i FT AND s FT
YivId nolec 7 til. /'j,F.,/>
PERFORMED BY: XI '- ! /i'AF' CERTIFIED BY:
1220 West 25th Auenue 9 Anchorage, Alaska 99503 0 (904 276-1361
DATE: /% A
2-013 (Rev. 3/78)
MUNICIPALITY OF ANCHORAGE�•..�
/ ®
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
I
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME
-
PHONE
❑j EW
0 C"� -
j. � 411eUPGRADE
MAILING ADDRESS
LEGAL DESCRIPTION
LOCATION
G,:
NO. OF BEDROOMS
.�
���.. �e F' %71�fP f.v.:Y P.SS �:•-sH2l
DISTANCE TO:
Well
Absorption area
Dwelling
PERMIT NO.
O
_Y
a Q
Manufacturer
Material
Noof compartments
w F.
V'
Lie. capacity in gallons
IF HOMEMADE:
Inside length
Width
Liquid depth
DISTANCE TO:
Well
Dwelling
PERMIT NO.
= z <
Manufacturer
Material
Liquid capacity m gallons
w=
DISTANCE TO:
Well
�'
FoundationK
� a
Nearest lot line
PERMIT NO.
J LL Z
No. of lines
Length of each line
Total length of lines
Trench width
Distance between lines
Wiz¢
96°
/``3
?2,,
�•>
Q F
¢'
Top of tile to finish
grade
!/
�
Material beneath rile
Total effective absorption area
a
-� Z
t inches
/ ?_. 0 -1
Length
Width
Depth
PERMIT NO.
W
O
iF
w�
Type of crib
Crib diameter
Crib depth
Total effective absorption area
w uJ
DISTANCE TO:
Well
Building foundation
Nearest lot line
Class
Depth
Driller
Distance to lot line
PERMIT NO.
DISTANCE TO:
Building foundation
Sewer line
Septic tank
Absorption area(s)
OTHER
PIPE MATERIALS
P v C
9
SOIL TEST RATING
INSTALLER
t3K
N
REMARKS
P s
C
V
17, ' s
II I
V
pap
APPROVED
DATE LEGAL
i?_,x- 8-2 7 k 5 zes� �� Z
2-013 (Rev. 3/78)
�l MUNICIPALITY OF ANCHORAGE
DEPARTMENT OFHEALTH& ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME
D & B GENERAL, INC. C.C. BUCK CONS^1RUCTION
PHONE
3t+9-6965
[NEW
❑ UPGRADE
MAILING ADDRESS
P. 0. BOX 10-1349, ANCHORAGE, ALASKA 99511
LEGAL DESCRIPTION -
Lot 2 Block 6 Talus West Subdv.
LOCATION
Wilderness Lane
NO. OF BEDROOMS 3-
Uy
DISTANCE TO:
Well
125'
Absorption area
S'
Dwelling
15,
PERMIT NO.
Handwritten
a z
Manufacturer
Greer
Material STL
No. of compartments
w
m
2
Liq. capacityi on,
08
IF HOMEMADE:
Inside length
Width
Liquid depth
DISTANCE TO:
Well
Dwelling
PERMIT NO.
MO z FQ-
Manufacturer
Material
Liquid capacity in gallons
DISTANCE TO:
Well 130
Foundation 20
Nearest lot line 1 '
5
PERMIT NO.
w=
u zNo.
of lines
Length of each line
Total length of lines
Trench width
Distance between lines
a w
1
66
66
36nches
n a
p..
Top of tile to finish grade -
4'
Material beneath the _
Total effective absorption area
a
0
84 inches
8g6 s
Length
Width
Depth
PERMIT NO.
w
0
aH
wd
Type of crib
Crib diameter
Crib depth
Total effective absorption area
w
DISTANCE TO:
Well
Building foundation
Nearest lot line -
Class
Depth
Driller
Distance to lot line
PERMIT NO.
J
DISTANCE T0:
Building foundation
Sewer line
Septic tank
Absorption area(s)
OTHER
PIPE ATERIALS MUNICIPALITY OF ANCHORAGEPVCCAST
flu
DF,r C= ['E IT I ^.
SOI L TEST RATI NG EW1 It. :J',, A- � D- -
250 sq.ft.
INSTALLER .i/i :! G h:6_
D & B GENERAL, INC.
REMARKS RECEIVE
ES
.
k �
OF 41
,
No. 2100• E •,sem
ACT 94
APPROVED DATE LEGAL
10-15-81 PELS
72-013 (Rev. 3/78)
January 4, 1982
Buck Construction
1577 C Street
Anchorage, AK 99501
Permit # 811097
Subject: L 2 B6 Talus West S/D
82 i "L" S'i RL.L- T
;1 OR/'VGE, ALASKA 99501
C -D R( r�M. SUL.L NAN,
u, YOP
A permit issued by this department for a well and/or sewer
system has expired as of December 31, 1981.
Permits are issued on a calendar year basis, as stated on
the permit, by authority of Municipal Ordinance.
If you have drilled the well, a well log should be sent to
this department to document the installation date.
If an engineer inspected the installation of the on-site
sewer system, please have them send us the as-builts for our
files.
If there are any further questions, please call this office
at 264-4720.
Sincerely,
Les N. Buchholz R.
Program Manager
Sewer and Water Program
Enclosure: Copy of Permit
�l #J r-.1 1 3::- 1 1.7 u-0 f_5 Fz- F::� P--1 3:17 F=lKa f=-
` f)EPARTMENT' 4EHLTH AND ENVIRONMENTAL ,TECTIQN
825 'L' 5TREET, ANCHORAGE, HK. 9950-1
264-4720
` . 1_4 a I I ��-r:- ��— _'F, I -'r EF_ 4E. E= 14 F_: F;? r=F--F="M I -F
PERMIT NO. ( 811097 )
APPLICANT BUCK CONSTRUCTION 1577 C STREET 995011 276-1614
LOCATION WILDNERNESS DRIVE
LEGAL L 2B 6 TRk.NS WEST S//D LOT SIZE 39538 SQUARE FEET
TYPE OF SOIL ABSORPTION SYSTEM IS: TRENCH
MAXIMUM NUMBER OF BEDROOMS = I SOIL RATING (50 FT/BR)= 250
THE REQUIRED SIZE OF THE SOIL HBSORPTIQN SYSTEM IS:
�E: F=� -T'"= �-1 L_ E- " 1:3'T- H -- te5!ff- 1:3 F-* I �E=F=� -T " � T`
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRHINFIELD.
THE DEPTH OF H TRENCH OR PIT IS THf_ P,1STANCE BETWEEN THE -SURFACE OF THE
GROUND AND THE BOTTOM OF THE EX TION (DN FEET),
THERE IS NO SET WIDTH FOR TRENCHES
THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL. BETWEEN THE OUTFALL PIPE
AND THE BOTTOM OF THE EXCAVATION (IN FEET).
��r-J1K :L"- 0210 ������40H.
PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DURING THE
INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE
NUMBER OF RESIDENCES THAT THE WELL WILL SERVE.
-r L-A CD ��--- I r -4!F. F:�� FE -T- :1 IZ, r-4 _� �F�-:_l F-_ �F= li! 91 1 F-7 �= EN __—
B8CKFILLINS OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS
DEPARTMENT WILL BE SUBJECT TO PROSECUTION,
MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEIWAGE DISPOSAL SYSTEM IS
100 FEET FOR A PRIYHTE WELL OR 150 TO 200 FEET FROM 8 PUBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC WELL
MINIMUM DISTANCE FROM H PRIVATE WELO A PRIVATE SEWER LINE IS 25 FEET AND
v�
'TO H COMMUNITY SEWER LINE IS 754,,,0EET.l '^
WELL LOGS ARE REQUIRED AND MMST'BE RETURNED TO THE DEPARTMENT WITHIN 20 DAYS
OF THE WELL COMPLETION,
OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE
AVAILABLE TO INSURE PROPER INSTALLATION.
���M I -r ���I F:;? E -:!E-7- CA C_- E"r-1 E3 F= F;;?- 2- -1 �so NE� -1
I CERTIFY THAT
1� 1 HM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
]: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THAN ] BEDROOMS,
SIGNED:_~_------_----__--~~~-_-~-_-_-.^-
HPPLICHNT BUCK CONSTRUCTION
L
/
ISSUED BY ----------- ---------------------- V4, 0
.�. ifiNICfPAi.!Ti (!i :4 N{.f !CIizHC�
Depar#,K;ann Of awth and gTl`I'iron ient_=LIP i'rotec tioq
Streot, AnChorag& A& 99351
2"4720
HANDWRITTEN PERMU
WEI t r�Iill E)n O SI rl fi�i'�Gr�'i PERMIT
�' rF w#
f F i �` � t -j'
type oC Soil Abgorptlon System in:
Trench: r:aill";ie}moi. �,'Gd _ F€C3Vl_.t1« Tank;
Aagtmu,o itltFtber :if P-ecD..-:0oilS: _ :500
The iiCa9l,#Uad r ize Of thl 1011 AWOCKIOU aY". In:
J/f
D ¢:# _ {-- 1 h?i }i .._�.: GRAVEL DEPTH � �'€II2i -----------
The length dimension in the le[Tq0(t,#^, foot) of the trench Oe drairtfield 1h
depth of a E:,r anU oc pit Q the distanco between she si_3r{:ave or is a rouirQ i!
the bottom of the exc avation(in fnyh). `here is no aet Si*1dth cm: T��Z_tii5Y27;ta,
ha < s'avol. anptSi iz sfl minimum dopt` of gravel between the outfall pipe ''rd
thta ? tt e:i?ru oC the axn va -t<r (ih Kvt),
s3EQUIRCD `EPTIC(HOLOINS rAMK SIZ.
vowmtt <#IpI3i_l<<;aac han th* responsibility lit to into?;`m thin d epa7'[.Tii%'nt during F:0l
Ins al taLtoa inspection, of any EfpLig adl,ci^; nt: to thin S]=ilarhY and the n Jg&c
oc residences that the well will wawa' '
a�
` a 00(0 fNSP C:E iOit a ARE R U(S U z
Backcillfalg of any syston, W;1'hout Oral %nep onion and approval by this stiepal.t
will by Subject to prosvnutioh
minimum &Gtaocy botstfseD`well and any oh --lin wawa e *:��..'-S{>o:'s<�.: i'-yGtel is .lot,
Eor= a til Nate wel.%L.-or t. `50 �;;o 200 Vii; t iron A C1><trLiv wal"L depeClLIini upon obs t?
of public well, Mt.3S?CC$!..n d0tanoa IrOn a PrIvaty well to c; Private sswe' llc
i`3 20 feet and to a cCi(i'3tiunity sawar line is ?i Vet.. Well l_:Jgn :3r€3 ri1qI,i:-rod
and must he rat.urnow to this 05yartsony within 30 days of the wall t.{1€Ztpl..oUca
alt,>£ar r aqu t-2-'rlenj may pp4y, a�?£:?}.t i. „gl�i{3z2 and Connt':l:uatton diagYamt .3'M
a,i;?1_.#-etblo to Insure propos 6 ll6$-all.,x(_3_04.
i PERt'if f i<X!-'!':t.J DECEMBER ii
t Certify that:
( _}
1. aR familiar ttl.t}l the ��'L l?<t'Ci',-`_'. tl i` toc {]F3 -=.t 3,f_.._ tif=tdis`i'S and
i�'.=l. l.; av,
got forth lel, the Municipality
pis` nus; O l ,
i/ l{
3 w l install tho ay han in
,eco auc: with
c. L_d.
V.3al
1 gnderntand that the on -SU,
sewlar gynto.
may rg_quira E
the residence sidee\nce reste sled to
include more
that
i; _ig neta :
`iB
:.1
xpp S-icant
}} A
L,wpIttL,4(Uf;1)
MUNICIPALITY OF ANCHORAGE
• ae DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L. Street, Anchorage, Alaska 99501 264-4720
SOILS LOG - PERCOLATION TEST
Ei' SOILS LOG
I� PERCOLATION
TEST
PERFORMED FOR: 6(f Y�,Y) S m6 Ji -N t- DATE PERFORMED:
LEGAL DESCRIPTION:_ L_nT JIRXiK QB --'WVS W•es'T'
0
c
y
' `MUNICIPALITY OF ANCHORAipJ Pr
444 DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION TEST
825 L. Stroat, Anchorage, Alaska 99501 264-4720
ai
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: 7%BV vt 1 S S-- t/ M DATE PERFORMED: �
•F- c,. i.. J . S,,•f2T,W Em,
LEGAL. DESCRI
Spmrj,i DEPT,
IF ET
® 2 � M 1-
3
Vl' q
M L
1
Ljr Loyrr
6
t4 L
6-
Kr I
7 -
all
I %2' r -`►i) Per,.+
C_"r S" SL t✓0'V5fi
SI` ScL Layarrt,7 lu(orit
Sa S� 'St rriK ,r tyars�—IV�t
6r f4c)1!
..'vI Iratcr.1,
S ,S
P. 4, Sc tr. a SAr
�r.•.'e.i •— Plasf�t-- U.'.'1
S'�tlafie-n
9
Gr
Date On
4
1
Ljr Loyrr
lo-
A'1 L.
S.•- � r ��
ll
blas t"t-
olet (O Inient�
12Ts::
5; SA.. we .
13
MQ
•,
14-
413
is-
16 -
16
17
17
18
NEIL HAWTHO
1,1�. 17,Sr
19
SLOPE
WAS GROUND WATER Y@S S
ENCOUNTERED? C
IF YES, AT WHAT T r 8 1 11c' r la.-T'Ci E
DEPTH?
4'/1 dfi4f2_.%/sem
�rVr . It
/ SITE P
Reading
Gr
Date On
4
Net
ime
Depth to
Water
Net
Drop
v
ppO • aa••a•••pa
D�
.AOQO
49TH
•,
NEIL HAWTHO
4w •
..
CE -4369
D
47
Q f -t ' . T.urta
Ao
■■■WIg■■
■■12■■
Reading
Gr
Date On
4
Net
ime
Depth to
Water
Net
Drop
v
ppO • aa••a•••pa
D�
.AOQO
49TH
•,
NEIL HAWTHO
4w •
..
CE -4369
D
47
Q f -t ' . T.urta
Ao
20
IL— JI 1 PERCOLATION RATE Iminuteslinchl
9. 3r TEST RUN BETWEEN �' FT AND Z— FT 17¢I'c 14, IP I
COMMENTS
Uo l h i@Y[• y 'C - ! 1 r_evIr I "'Z'
PERFORMED BY:__; / � - - CERTIFIED BY: iV DATE:
?Jo:4 1ln,.ilL,Gt'NC C cir 603'"03I
Well Log
For ........ Pr
...................................................................... ............ .........................
I - - -7-
2-7 L -Ir -s
Location....... <. 0 71 .........................................................................................................
// -Z- , "%:;,/
Date completed..................................................... OF.ANMO-pLA6E
6W" T,j
/ ; 0
Depthof well ..........'5.........0................................................................................
Size of casing .......... .................................................
....................
Distance to water......... . ........ .......................................... IYEP .........
Distance to
water while
pumping ..................
J..7 . ........................... at rate
of ..........................
1.8.0 ............
gallons per
hour.
Formation
I from
I to
c-(4zv
O
//
eLy c
7- Z.
G-424 V6,1- rZ44'z
-V -e- -
............. ;/ .... .....
............................................
Driller
DELTA DRILLING COMPANY
BRA BOX 394 B
ANCHORAGE. ALASKA 99507
gra�-7 am
±�
9®®
�
�
Q
■
0
aQ
ooh A y — 74Cff25-'PFI!AW—
0.
4
f�
E3 ..
in
Q
�x
oS 'A
q 2
Y M
� i
r
aQ
ooh A y — 74Cff25-'PFI!AW—
I
4
f�
E3 ..
in
Q
�x
oS 'A
q 2
Y M
� i
� V
VY
71N"
C
i
�
y
,
u
44 vj
o Y
L S y
QL
I
� � GbU f35
N
NNi
a
a°
n
co
m
W
s
e
min
w o
N
N
NO
L
o
rn
m
z
m
ro
w
Z
v
T
CD
<�a
o
U%
fn
m .
'
r
�T
h _
b
m04B
r N
ti
r
r IY
N
NNi
a
a°
n
co
m
m
z
r
<
TTIv
CD
L
o
rn
m
z
m
w
Z
v
T
Z
m
<�a
o
U%
m K
'Id .•
m
6-0
r
�T
p
b
r
ti
-
C'
F
(n
<
m
N Oe
w
0
I
i4
N E
n m
"W 107000' -- 97.'00'
R : a., _
-WIt,DERNFps_ p�tvg
o �
0
(II
'I.
co
z
r
<
TTIv
�'
x
m
rn
m
z
w
V. V
<
C
pTQ
m
O.
r
m
p
b
c
ti
-
C'
h
x
(n
<
m
z
m
o
x
to
N
-{
i
ro
m
)>
o
H
x
p
�
o
N
' CONTROL btKVIVC" IIIV. - - SHEET tW,--� "' w
12M West 33rd Avenue e B CALCULATED BY DATE
ANCHORAGE, ALASKA 99503
PIIOM 276.1361 CHECKED DATE —.
SCALE '
S i
iP
FIA .. ... .. ..1 .. i. _. t—.1 ..L-
N, AJGPM"n't'dS t 4 Y P.In
�.vry i ircv� stKncr� . mom.
1200 West 33rd AvenelSuite B
,ANCHORAGE, ALASKA 5503
Phone 276-1361
SHEET NO. ^^ OF -7
CALCULATED BY CC I DATE
CHECKED BY
DATE
CONTROL SERVIC� INC.
1200 West 33rd Avenu —Suite B
ANCHORAGE, ALASKA 99503
Phone 276.1361
SHEET NO.�OF /
CALCULATED er Re�'l DATE
CHECKED BY DATE
1200 West 33rd Avenu' Suite B
ANCHORAGE, ALASKH`-49503
Phone 276-1361
BHEETNO. / OE_
CALCULATED BY �-) DATE
CHECKED By
DATE
Time
APPLIC, FILLS OUT UPPER HAL,,—,ONLY
-
Time
_,IT
Property Owns
/a�CK ea�/S %%�UC%�/1���
Phone
Mailing address
�/�� �7 % "'� /4/V cr Zip Code
0-76-1110f/
Buyer
Inspector
-
Address
Zip Code
Lending Institution
A`,
Phone
Address
Zip Code
Realty Co. & Agent
/C/_`/9L r'5
Phone
Address S %(%/Fi 111598- 144 Zip Code '
Legal Description
A o ( /�7
Street Location
�N/1/ L✓/� .vF� �.. S
Type of Residence
HI) V LA-S,�,
9 Single Family
c_0w.p. rto� w.vcG.
u^12�
❑ Multiple Family
No. of Bedrooms
❑ Other
-Wat✓:r Supply ,.
DATE
)?9. Individual - ..
ATTACH WELL LOG. A well log is required for all wells drilled
since June 1975.
❑ Community
Soils Rating
For wells drilled prior to that date, give well depth (attach log
if available).
❑ Public Utility
tS
I a � � �.• �
Sewer Disposal
Septic Tank Size
,K Individual
Year Individual Installed:
❑ Public Utility
When Connected to Public Utility:
❑ Holding Tank
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
Time
Time
-
Time
Time
D
Date
Date
Date
Inspector
Inspector
-
Inspector
Inspector
W
Field N.7es:
HI) V LA-S,�,
c_0w.p. rto� w.vcG.
u^12�
(?,,)-APPROVED BEDROOMS
'CONDITIONS OF APPROVAL
( ) DISAPPROVED
( ) CONDITIONAL APPROVAL'
DATE
BY:
Soils Rating
Date Sewer Installed
Well To Absorption Area 1 (,
Well Log Received
tS
I a � � �.• �
Well to Tank � a -Sr
Septic Tank Size
72.023 INK)
!J�
unicip"lily
of
PC, 'H 6-650
ANCHORAGE, ALASKA 99502-0650
(907) 264-4111
TONY KNO WL ES,
MANOR
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
October 31, 1984
Leroy C. Reid, PE, PhD
Alaska Environmental Control Services
1200 W. 33rd Ave., Suite B
Anchorage, Alaska 99503
Dear Lee:
The Department approves of the curtain drain design for Lot 2,
Block 6, Talus West Subdivision, and the intent to re -activate the
abandoned wastewater disposal system, under the following con-
ditions:
1. A minimum 15 -foot seperation distance is maintained between
the curtain drain and the absorption field, consisting of
undisturbed earth.
2. Data is presented to the Department documenting a drop in
water level beneath the absorption field sufficient to pro-
tect the ground water table and meeting the 4 -foot separa-
tion distance;
3. An upgrade permit is obtained for abandoning the holding
tank, re -connecting the septic tank to the absorption
field, and for performing any remedial work on the field.
4. An adequacy test is conducted on the system following hook-
up.
If you have any questions, please call me at 264-4720.
Sincerely,
Keith E. Bandt
Environmental Engineering Manager
KB1/ra/d4
ALASKA 6--rdIROnUTAL COnTROL Sekv(US, IX
Engineerinq & Enuironmental Studies MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION:'
October 30, 1984
Department of Health and
Environmental Protection
825 L Street
Anchorage, Alaska 99501
Dear Keith:
OCT 01984
As you are probably aware the system on Lot 2, Block 6 - Talus West
Subdivision has been abandoned. A study I made this sumrler indicates
that the groundwater level on the lot is above the bottom of the bed. I
propose to install a curtain drain to drop the water level to at least 4
feet below the bottom of the system.
After the curtain drain is installed we would like to reconnect the
system. Our soils tests indicates that the system will work. I have
enclosed a copy of the soils test which is about the center of the bed.
If you have any questions, please let me know.
Sincerely,
4r y eid, Jr „ PhD, P.E.
Pre 'd nt
1200 West 33rd Auenue, Suite B • Ane6orage, Alaska 99503-(907) 561-5040
i
7127 OLD SEWARD HIGHWAY
_ ANCHORAGE, ALASKA 99502
MUNICIPALITY OF ANCHOWCU-344-4711
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECFIOM
OCT 3 11984
October 30, 1984 RECEIVED'
C
Mr. Dennis Smith
1081 Gayley
Los Angeles, CA 90024
iE: Lot 2, Block 6, Talus West Subdivision, Anchorage, Alaska
Dear Mr. Smith:
I received some sketches today from Mr. C. C. Buck which
Alaska Environmental Control Services (AECS) had prepared showing
a proposed curtain drain system to lower ground water on yow
lot so that the existing bed sewage disposal system could be
used. While it is possible that this idea will make your system
acceptable, I would not recommend it. As I have said before, I
recommend that a new mound system be installed along the east
side of your property.
i talked with Mr. Robert Robinson of the Anchorage
Department of Health and Environmental Protection (DHEP) today.
He said that AECS plans to monitor ground water on your property
to see if the curtain drain lowers it to four feet below the
existing bed system. If the water level is sufficiently lowered
DHEP will require a percolation or adequacy test to prove that
the original receiving soils below the bed will accept the sewage
flow. The original percolation test (7-14-81.) was not properly
I
done and does not verify the 250 square feet per bedroom figure
used for the bed design. Mr. Robinson also stated that the bed
insulation will have to be replaced where damaged and that two
feet minimum of earth will have to cover all portions of the bed.
The missing silt barrier (Visqueen) problem should also be
addressed.
Scaling from the sketch by AECS, sheet 3 of 4, dated July
22, 1984, indicates that the bed may be as close as 10 feet from
the curtain drain at one point. This is not acceptable because
effluent might easily find its way to the curtain drain. Both
DHEP and I recommend a separation distance of at least 30 feet
although DHEP may approve a lesser distance.
I feel that 79 linear feet of curtain drain with an eight
foot depth is inadequate. Any ground water migrating from the
north or northeast may not be intercepted unless the driveway and
house foundation have a sufficient depth of gravel and they are
properly drained to daylight. Your history of problems with the
wet crawl space may shed some light on this. The eight foot
depth may not be enough to lower ground water to four feet below
the bed system. My measurements showed that there is about a 10
to 11 feet elevation difference from the ground surface at the
east property line (highest point) to a level four feet below the
existing bed gravel.
The curtain drain (Miradrain) should probably have oversized
rock on each side and around the perforated pipe to prevent
closing off the water channels by soil pressure or migrating
silt. It is quite possible for a curtain drain to fail years
after construction if certain precautions are not taken.
4
If the ground water level can be properly monitored later
the standpipes shown on the AECS sketch should be slotted and
installed at least four feet below the bed gravel, not to the
bottom of the system as shown.
I never have thought that a curtain drain system on this
site is the best choice. Costs are high for installation while
success is less than assured. My letter of September 19, 1983 to
DHEP suggests that a mound system would be the best choice and
that opinion is reinforced in my October 5, 1984 letter to you.
We installed a second 1000 gallon tank on your property last year
for a holding tank, but also so that it could be used as a lift
station for a mound.
If the curtain drain is installed where proposed my
anticipated area for a mound could not be used because of the
horizontal separation distance requirement between a mound and a
curtain drain. I am not sure if a permit could be obtained but,
if the curtain drain is installed, it would leave more options
open if it was installed in the road right-of-way.
Based on my soils test in 1983, I question whether the
receiving soil will pass a proper percolation test after it is
dried out. Laboratory analyses showed very fine soil grain sizes
which usually indicates an extremely slow or zero percolation
rate. In 1983 I tried a percolation test at 3.0 to 3.5 feet
below the surface (1.5 feet above the ultimate ground water table
at that time) which failed.
3
Please be aware of three things: 1) A curtain drain as
proposed may or may not lower the ground water table
sufficiently. 2) If the ground water is lowered to four feet
below the existing bed system the receiving soils may still not
pass a percolation test which would make the existing bed system
unuseable. 3) If the curtain drain system is tried and it fails,
the suitable area for a mound system will be significantly
reduced.
If you have the contractor warranty the work you should
probably include the stipulation that the disposal system will be
required to pass an adequacy test per DHEP standards at -the end
of the warranty period. This is the same test that any system
must pass before a house can be sold.
Sincerely,
Neil Hawthorne
cc: Raymond Royce
Joe Huddleston
Robert Robinson
NHAWTH®RNE®ENGINEERING
.sa�ie-jos
A-tC OWXGE-. P L -As A-99563—
NHAW7HORNE - ENGINEERING 907-277- -CO9
October 19, 1983 7127 Old Seward Highway
Anch., AK 99502 34404711
Mr. Jim Roberts
Anchorage Department of Health and Environmental Protection
825 L Street
Anchorage, Alaska
Re: Dennis Smith property
Lot 2, Block 6, Talus West Subdivision
Dear Mr. Roberts,
This letter is to inform you that I have inspected the holding tank
installation on the above named property. A second 1,000 gallon tank
was added so that now there is 2,000 gallons total storage. The second
tank's outlet is capped off.
We also inspected the failed leach field (bed) by exposing the
perforated pipe at the tee near the tank and at the Southeast and Southwest
corners. It appears that the field was properly constructed based on
what we saw except for two items. There is only about 1 inch of gravel
above the pipe and the tee is 0.2 feet lower than the two corners. Neither
of these items would have caused the system to fail however. I still
believe that the percolation test was not done properly, a permit should
not have been granted, and the inspection may not have been adequate.
Water level in the system was above the bottom of the perforated
pipe. When the lower corner (S.W.) was exposed water ran freely from
the field area. Fourteen gallons of bleach were used to prevent possible
bacterial problems.
If a special system is designed next year, more Perc Tests should
be required.
Please call if you have any questions.
Sincerely,
Neil Hawthorne
NH/pe
October 5, 1984
Mr. Dennis Smith
11670 Wilderness Drive
SR 1641-G
Anchorage, AK 99507
RE: Sewage Disposal System, Lot 2, Blk 6 Talus West Subdivision
Dear Mr. Smith:
Mr. Joe Huddleston asked today that I expand on my previous
correspondence with you concerning possible alternatives and
their costs for a sewage disposal system on the above lot. This
is my response to that request. -
As I mentioned in my August 2, 198X'letter to you, there are
three options to consider. Those are a curtain drain with bed or
trench system, mound system, or a sand filter. Each system was
discussed in that letter but costs this year seem to be 20% or
more higher than I quoted partly because gravel has increased in
price.
A sand filter may not be a good choice because you have no
major drainage nearby, the concept is new and not entirely
accepted, and it requires periodic maintenance. A curtain
drain, while possibly cheaper than a mound, requires reasonably
permeable soils for a conventional disposal system. My test hole
showed questionable soils for such a system and one never knows
if a curtain drain will work until after it is installed.
1
°s
My opinion is that a mound system is the best choice at this
time assuming that percolation tests in the existing soil show
that it will accept the effluent. I did three such tests in the
southeast corner of your lot last year and found rates of 30
minutes per inch to greater than 120 minutes per inch at around 2
feet below the surface. I feel that additional testing will find
an area and depth that can be used for a mound.
Costs for the construction of mounds vary greatly depending
on the depth of the receiving soils and the percolation rate. I
did one three years ago that cost $21,500, while I am aware of
others this year that cost less than $15,000 including
engineering fees. A rough estimate for such a system on your lot
(1984 dollars) is $20,000 to $25,000 plus whatever it cost you
last year to install the second holding tank. A breakdown of
those costs is as follows:
Lift Station - $500.00 plus your previous tank costs
Engineering to Date attributable to mound system - $1200.00
Future Engineering - Mound Design, etc. - $1500.00
Mound Construction - $18,000.00
15% Contingency - $3000.00
Again I say that these costs can vary greatly depending on
specifics of the site. True costs cannot be estimated until
additional field work is completed.
I hope this,letter answers your questions.
Sincerely,
Neil Hawthorne
2
IA,.?. k'S.�'a�il���rCf�..�
POU /H 6-650
ANCHORAGE, ALASKA 99502-0650
(907)264-4111
TONY KNOW1 ES.
MAYOR
DEPARI"MEN T OF HEALTH AND ENVIRONMENTAL PROTECTION
September 28, 1983
Hawthorne Engineering
7127 Old Seward Highway
Anchorage, Alaska 99502
Subject: Lot 2 Block 6 Talus West Subdivision
Owner: Dennis Smith, Star Route A Box 1641G
The Department of Health and Environmental Protection will issue
a temporary holding tank permit if the following conditions are
met:
(1) Make application, if the department inspects there will
be a $20.00 permit fee. If a registered engineer inspects
the fees are waived.
(2) A copy of a weekly pumping contract be submitted to this
department.
I£ there are any further questions, please call this office
at 264-4720. ,- \
Sincerely,
Robert W. Robinson
Acting Division Ma
RWR/ljw
cc: Dennis Smith
Star Route A Box
Anchorage 99502
/ q -7
41G
MUNI
DEPT. OFOHEP'THS&RAGE
PT.
E�IROV PROTECTION
RECEIVED
September 19, 1983
Mr. Robert Robinson
Department of Health & Environmental Protection
825 L Street
Anchorage, Alaska 99501
Re: Lot 2 Block 6 Talus West Subd.
Owner: Mr. Dennis Smith
Dear Mr. Robinson:
Following our meeting with Mr. Smith on September 13, 1983
and per your recommendation, I conducted three additional
percolation tests on the above property. Those tests were to
determine if a modified seepage bed or mound could reasonably
be constructed this year because of the property's failed leach
field. Mr. Smith now has.the original test result forms.
The tests were conducted on what I felt was the most likely
area for a new system. The north end of the area perc'ed at
30 minutes per inch at 2 feet but the south end had a rate of
120 minutes per inch or greater in two test holes at the same
depth. Ground water has been at .5 feet each time I measured
it since July of this year.
I feel that a modified mound system could be designed and,
with careful inspection during construction, it would prove
to be satifactory. However, due to the approaching winter season,
possible litigation and the slow percolation rates, I feel a
one year holding tank permit should be issued to Mr. Smith.
You agreed with me on that point in our telephone conversation
of September 16, 1983.
A condition of that permit should be a temporary cap
installed on the existing septic tank outlet.
Please contact me if you have further questions.
Sincerely,
Neil Hawthorne
Engineer
cc Dennis Smith
F-Z�-Y`3
TE -40
?02n "Ob r
dz,
100
90
BO
apATfilJT7F IN MILLIMETERS
20 20
10
D 1
100
10 1
DIAMETER ®
SOX 1E-03
DIAMETER @
30% 5E-03
DIAMETER @
50% _016
CU= 15
CZ- 1.563
1
L 11
90
80
70
50
50
40
30
20
10
0
SIEVE %PASSING
3.0 100
2.0 100
1.5 100
1.0 100
3/4 100
1/2 100
3/B 99. 2
# 4 98.5
# 10 97.3
# 20 96
# 40 95.1
# 60 94.1
# 100 92.8
# 200 90.2
. 02MM 54-4
.00SMM 30.7
. 002MM 14.5
. U1
SPECIFIC GRAVITY ASSUMED AT 2.72
PLASTIC LIMIT = 16.2
LIQUID LIMIT 21.7
PLASTIC INDEX= 3.5
SAMPLE SOURCE
D. SMITH
BORING 1 SAMPLE 3
DEPTH 6.0-6.5 FEET
JML LABORATORIES INC.
JOB NO. 63-424.09L AP DATE a -1-B3
CLASSIFICATION
SILT ML F4
PARTICLE SIZE ANALYSISI PLA
NEIL HAWTHORNE
4C30FZue-%CEE IALH'*g IL A. C %IL- JL ® y
-17
DATE OPENED: 07/2S/93 [)AT[-" CLOSED.
COMPLAINT CODE: 4 NATURE" SEWAGE
COMPLAINTANT' BUCK, CC ZIP CODE
LOCATED A17 : NONE
COMPLAINT DETAILS' OVERFLOW SEWAGE
-
I lyl-e
CASE OFFICER: OSWALT
PHONE NUMBER' NO PHONE
Z
0
-Iz-m-u m(nDmr-u
r0
CO 1
n
�Z-a7'a
m(n D mr-0
O
0
r
D
N
z ❑
❑
❑
D
O
00
O
r
(n
co x
z O
N z
C
(.A)
0
m
y
O
m
-0i
a
z
�n
0
0
m
O
O
D
0
m
m
m
**
z
D 2
�II!
Z
��
Z 3 O
0
c
�
Dm.
o
r
�Cl)
D
w
O
S
Z
o
O
1,
m
D
<
\
�
o
3
a
O
2
m
(o
D
O
m
m
DO
a
rr
0
r0
(i
icE
(C1
C
N
v
0
O
Z
�
1
0x
O
m
0
m
xi0
D
Cl)
z
mo
m
D
O
0
D
r
Z
0
-Iz-m-u m(nDmr-u
r0
CO 1
n
v
m
Z
D
N
z ❑
❑
❑
m
m
z
1
co x
z O
z
C
C
(.A)
D c
3CO
D
z
X
_n
I
m z
z
0
Z 1
0
O
D
0 m
r
m
7
z
D 2
�II!
Z
��
Z 3 O
zn
Dm.
r
�Cl)
❑❑�
w
O
o
O
y
m
n
o
-i
a
O
2
m
(o
D
O
m
m
a
0
(i
O
Z
D
0x
O
D
Cl)
z
mo
m
D
O
D
r
C:
1
DV
q
N
,
m
D
.x
i
m
m
z
1
O
n
mz
m
_n
I
; --I 9
N 2 D
Z D
Z 1
n a-
0 m
Z
z
D 2
Z
��
Z 3 O
zn
Dm.
r
V
w
O
1
m
n
-i
O
2
July 19, 1983
C C Buck Construction
4431 East 2nd Avenue
Anchorage, Ak. 99504
RE: Lot 2 Block 6
Talus West Subdivision
Q COY R GU41ERAL
INC."
General Cord ractors
PO. BOX 111349
ANCHORAGE, ALASKA 99511
(907) 349-6965 ,
Cc,
Enclosed is a copy of a letter from Alaska Environmental
Control Services regarding the requested visit by you to the
above referenced lot and sewer system which we installed last
year.
It appears, as stated in the letter, that the damage to
this system is recent and we did note that landscapers are
presently working on the north side of the house and told us
that some other crew members of theirs did work on the south
side.
The system previously had two and one half (22') feet of
cover as noted on the inspection report of last year. So,
someone has stripped the site and this should be repaired.
If we can be of further assistance, please let us know.
Sincerely,
D & B GENERAL, INC.
Doug as R. Bloom
Sec etaryf-Tresurer
DRB:bks"
enclosure
�J
ALASKA RUIROMPTAC CONROL KnUINS, InC.
Engineerinq & Enuironmenlal Sludies
July 18, 1983
D & B General
P.O. Box 111349
Anchorage, Alaska 99511
Attn: Doug
Dear Doug:
On Monday July 18, 1983 in your presence, I visited C. C.
Buck's place located in Talus West Subdivision Lot 2 Block
6. On visiting the site I dug several test holes across the
field and found that on the extreme southwestern side of the
field the insulation for the sewage system is only 2 inches
below the top of the ground. After further digging it
appears that some of the insulation has been stripped off of
the system. Pieceslof insulation and visqueen were found
laying about the yard as well as approximately 3 foot
section of perforated plastic pipe. The sump for the field
has also been dug up and is setting against a birch tree on
the east side of the lot. See the attached sketch.
A backhoe should be brought in and the edge of the system be
exposed to determine the extent of the damage done to the
distribution pipe. It would appear that the distribution
pipe may be cut since the edge of the field that is
approximately 3 feet from the edge of the rock is where the
water is coming out of the system. The system should then
be repaired.
Also, the lawn should be regraded to show a minimum of 2.5
foot cover over the entire field. That would mean that the
west side would have to be brought up to approximately 2.5
feet and tapered to a 1 on 3 slope.
The front of the lot is graded in such a manner that any
water coming down the road ditch will drain onto the lot and
onto the sewer system therefore causing to premature failure
of the system.
It is my belief that this damage is recent. If it had
occurred earlier I would have expected to seg lush
vegetative growth at the edge of the lawn. At 'any rate
there should have been at least 2.5 to 3 foot of cover over
the system to keep it from freezing.
It is recommended that a backhoe be brought in and the
system be restored and additional fill, preferably a sandy
silt, be brought in to prepare the proper grading.
Discharge of septic sewage to the ground surface is a
violation of Municipal Regulations. Prompt action is needed
,to prevent citations.
if you have any questions please let me know.
Sincerely,
Pres
C. Xe id Jr,, 6RhD PE
August 10, 19€ 2
;luck. Construction
4431 1's. 2nd
Anchorage, AK 99504
Subject: Lot 2 Block G Talus West
Approval for the individual sewer and water facilities cannot
be granted until the following items have been completed:
° The depression or pit around the well rasing needs to be
filled with impervious type soil so that it slopes away
from the well casing.
\n�The water analysis report needs to be submitted to this
office from the Chem Lab, 5633 P Street_, for. our -review.
During the inspection, it was noticed that 50 feet of gar-
den nose was extending from the drain fields sump. Further
\ investigation revealed that the septic tank was not full
and the soils test indicated water at 15 feet on July 15,
oN \n 19BI. Since the house is unoccupied at this time, you will
J cneed to have the trench recertified by your original soils
(� tester (Alaska Environmental Control. Services) that there
is no water table at 15 feet.
Please notifv this Department for a reinspection when the
noted discrepancies have been corrected. If there are any
further questions, please call this office at 264-472.0.
Sincerely,
Cory Willis, R.S.
CS?1/p/EFi
C
C
C
F
S
m
U
IX
�-- Municipality of Anchorage
• Development Services Department
Building Safety Division r
On -Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, AK 99507
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 015-202-59
1. GENERAL INFORMATION
COSA# Q5C 101 X51
Expiration Date: _3----2!i l
Complete legal description Talus West Subdivision No. 2, Block 6, Lot 2
Location (site address) 11670 Wilderness Drive Anchorage, AK 99516
Current Property owner(s) Dennis J. Smith Day phone
Mailing address 11670 Wilderness Drive Anchorage, AK 99516
Lending agency
Mailing address
Real Estate Agent
Mailing Address
Unless othenmise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: Three (3)
Day phone
Day phone
3. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
✓❑
Individual On-site
❑
Individual Water Storage
❑
Individual Holding Tank
❑✓
Community Class Well
❑
Community On-site
❑
Public Water System
❑
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E.
Phone 522-7773
Date 12/27/2010
% VO : MI W. a E ANDERSON d
5. DSD SIGNATURE
CE -4381
„�
pZP27-119
•
Approved for bedrooms. r4
,+�1+ PRO ••• 14N�x. �4
Disapproved.
Conditional approval for bedrooms, with the following stipulations:
Attachments:
COSA Checklist X
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
VMSTEWATER
GRAM
% = Q�
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
By: Original Certificate Date:
(Rev. 11/05)
y,
r:
b'
�A�
b,
1
D. LIFT STATION
Date installed Size, in gallons Manhole/Access (Y/N)
"Pump on" level at in. "Pump ofF level at in. - -`High water alarm level at in.
Datum Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DOANCES
SEPARATION DISTANCES FROM'UUELL ON LOT TO:
Septic tank/lift station on lot N/ On adjacent lots >100,
Absorption field on lot NIA On adjacent lots >1W
Public sear r main NIA,Public sewer manhole/cleanout WA'
Severer /sepfic service'line >25 Holding tank >75'
Animal con taiManure/animal excrete storage areas >100'
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Budding foundation '>5' Property line >5 Absorption field >5'
Water main WA Water service line >10' Surface water >100`
Wells on adjacent loft >1,00'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line Building foundation Water main
Water Service line Surface water Driveway, parking/vehide storage
Curtain drain Wells oon adjacent lots
F. COMMENTS: How Tank System Consists of 2 -1,000 Gallon Tanks. The First Tank is a Standard Two Compartment.
i
Septic Tat* insWW in (%loner of 1981. The Second Tank is a One Compartment Hoiding Tank Installed in 1983. High Level Alarm
Was Mstelled my of 1986. .., �5 11 t
G. ENGIREEit'S CATtti4,0 "'A,;•'' "•.,S',I�
Oro
l cerNy. that /'have nrax wdu' hWrwgh field inspections and s
review of AMS cipal i6cords Haat i re above' systerrris are in
... 004
conformame, with MOA COSA=gudeMes m effect on this date. i� •••,.....,...�
Engineer's Printed Name Michael E. Anderson, P E: rp , 4SS1 AW
Date 12/27rMiO �� ���' �, v�
Ij
COSH Fee $ q Waiver Fee $
Date of Payment Date of Payment
Receipt Number _ f 3 D. 3 Receipt Number
(Rev. 11105)
SGS
SGS Ref.# 1106339001
Client Name Anderson Engineering
Prgject Name/# Tallis West S/D No 2 L2 B6
Client Sample ID Kitchen Sink Private Well Wate
Matrix Drinking Water
Printed Date/Time
12/07/2010 10:31
Collected Date/Time
11/29/2010 14:29
Received Date/Time
11/29/2010 15:55
Technical Director
Stephen C. Ede
Sample Remarks:
Alkalinity
161
10.0
Allowable Prep Analysis
SM20 2320B
Parameter
Results
LOQ Units
Method Container ID
Limits Date Date
Init
Metals by ICP/MS
ug/L
EP200.8
C
12/01/10 12/03/10
NRB
Hardness as CaCO3
202
5.00 mg/L
SM20 2340B
C
12/01/10 12/03/10
NRB
Waters Department
NRB
Arsenic
ND
5.00
ug/L
EP200.8
Total Nitrate/Nitrite-N
3.15
0.100 mg/L
SM20 450ONO3-F
B
12/02/10
AYC
Microbiology Laboratory
EP200.8
C
(<2000)
12/01/10 12/03/10
NRB
Cadmium
E. Coli
Negative
1 100mL
SM20 9223B
A
11/29/10
SDP
Total Coliform
Negative
I 100mL
SM20 9223B
A
11/29/10
SDP
Private Individual Analysis
Alkalinity
161
10.0
mg/L
SM20 2320B
D
11/30/10
LP
Aluminum
ND
20.0
ug/L
EP200.8
C
12/01/10 12/03/10
NRB
Antimony
ND
1.00
ug/L
EP200.8
C
(<6)
12/01/10 12/03/10
NRB
Arsenic
ND
5.00
ug/L
EP200.8
C
(<10)
12/01/10 12/03/10
NRB
Barium
12.5
3.00
ug/L
EP200.8
C
(<2000)
12/01/10 12/03/10
NRB
Cadmium
ND
0.500
ug/L
EP200.8
C
(<5)
12/01/10 12/03/10
NRB
Calcium
58800
500
ug/L
EP200.8
C
12/01/10 12/03/10
NRB
Chloride
17.7
0.100
mg/L
EPA 300.0
D
(<250)
11/30/10 12/01/10
SDP
Chromium
ND
2.00
ug/L
EP200.8
C
(<100)
12/01/10 12/03/10
NRB
CO3 Alkalinity
ND
10.0
mg/L,
SM20 2320B
D
11/30/10
LP
Conductivity
435
1.00
umhos/cm
SM20 2510B
D
11/30/10
LP
Copper
23.0
1.00
ug/L
EP200.8
C
(<1300)
12/01/10 12/03/10
NRB
Fluoride
ND
0.100
mg/L
EPA 300.0
D
(<2)
11/30/10 12/01/10
SDP
HCO3 Alkalinity
161
10.0
mg/L
SM20 2320B
D
11/30/10
LP
Iron
ND
250
ug/L
EP200.8
C
(<300)
12/01/10 12/03/10
NRB
From:User 1 907 865 6578 12/21/2010 14:59 #758 P.003/003
PROPOSED FINISHED FLOOR
�aI>� G CORNIER
- <SSL XSED "
ZONING DISROCT
LOT 1
FRONT OULUr. SEMAak
SIDE 9U6dNC Sk1BAIX
.S7ga?6'
� .
REAR eulorw gieAac
p9„e
5'ST. LIGHT ESMT. 89.69'
I
I3p'
10' NAIL. GAS ESMT.
II
o
o
-----20' PWR. & TELE. ESMT. 0 0
WELL h
I
c i
ifOD
I
1
o
I I
0
C;J
LO
04
°
W
I I
>
oaQ
267
I
EXISTING
HOUSE ? aRAV41. a.„lwAr
p V)
o
z I I
zo
w.e 27AI U)
I
�z
IIO
n
o
C. 0.
W
J
II
T LlGHT
T 30'
S89° 56'20"W 171.23'
LOT 3
UNDER NO CIRCUMSTANCES SHOULD AN AS–BUILT BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES.
THE SURVEYOR TAKES RESPONSIBILITY FOR THE INITIAL TRANSACTION ONLY AND ASSUMES FINANCIAL LIABILITY ONLY FOR THE COST OF THE SURVEY.
LISTED DISTANCES PREVAIL OVER SCALING. REPRODUCTION MAY CAUSE ERRORS IN SCALE.
LOT SURVEY SURVEY TYPE
SYMBOLS
❑ FDUNDATION AS–BUILT
E3FINAL STRUCTURE AS—BUILT
• SET REBAR ASPHALT
7 =F DRAINAGE
❑ PLOT PLAN ... AS–BUILT ...LOT
SURVEY ... TO
,..
o FOUND REBAR 0 –e WOOD FENCE � CONCRETE
AS–BUILrmptfy
A T .. 0 SET RECERTIFlCATtON AS–BUILT ... NO CORNERS SET
0D ASSUMED ELEV. �--*-- - METAL FENCE ® WOOD DECK
PLOT PLANS & LOT SURVEYS
NOTE:
IT IS THE RESPONSIBILITY OF THE BUILDER OR OWNER, PRIOR TO
ONLY THOSE IMPROVEMENTS ABOVE GROUND AND VISIBLE WILL BE
CONSTRUCTION, TO VERIFY
PROPOSED BUILDING GRADE RELATIVE
SHOWN_ FENCES, WELLS, SEPTIC CL.EANOUTS, SIDEWALKS, DRIVEWAYS,
TO FINISHED GRADE AND UTILITY CONNECTIONS AND TO DETERMINE
ETC., ARE SHOWN IN THEIR APPROXIMATE LOCATION, ONLY. SNOW
THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS
MAY PREVENT SOME IMPROVEMENTS FROM BEING SEEN AND LOCATED.
WHICH 00 NOT APPEAR ON THE RECORDED SUBDIVISION PLAT.
ALL DISTANCES ARE RECORD UNLESS OTHERWISE NOTED.
SURVEY CERTIFICATION
���rr11
•♦•-C OF•• ��
Prepared by
Robert E. Johns, Jr. & Assoc.
PLOT PLAN
Iha.byo ftNwtlh.wohyrddly.d»�ea
th. wt drd.n and d..ab.d Asan. ale time I
•,�P\ .... ' �
Professional Land Surveyors
h�
vvho a"na 0. w ro n . b..tit.r mr�
dkn dm. hN b.sl
��
- }r
Y
842 E.
ANCHORAGE, tALASKA 99501
Scale: 111 _ CO,
Rec. Lot S.F.
Rec. Plat File No.
mbaa. amid o�msc§
mr t
FOUNDATION AS–BUILT
� ”"1"" ' "f
J
Date Surveyed:
12/05/10
Drawn by.
REJ
Checked
L
1, Rabat E JoM� Jr., hs.by mtIfy thA I
h . omfixr. a m A. 4Im5I &• y °fel•
}.omni. " W that 0 th. (
/ .,.....
• •••• • . ................
•• •
m aw
amatl.n m aha.a Avera
dw,a„.Im. aw Ilk
s ana_t. maws aa�
.•• • `
: RO RT . OHNS, JR.
J V V
Date Drown:
Grid:
:
12/07/10
SW2736
W.O.
1355
FINAL STRUCTURE AS–BUILT
elgt I
m
121— ��
�� �' •'•�J
•••'•..
•.
Legal Description:
9 P
I, Rabat E J.M& Jr., b y m.Nh
tht. M th.
e„ .•••• •
ed •••••'•
♦•
TALUS WEST 2
.bwtsa m W and that
dlm mlm as Wb—Mmta..Aowltnsaa„
and .: "a.°°�"" `d" �.4'
„ a�a
1 oaf' 4
�r�r�„�on:••�
BLOCK 6 LOT 2
12/27/2010 07:11 FAX 9073339776
Denali Sewer & Drain
Denali newel
Phone: (907) 333-5794
•._ ..� Fax: (90-1) 333-9776
TRUCK TICKET # CUSTOMER'S #
NAME
2 59
ADDRESS 11 r
CITY. STATE, ZIP
ARRIVAL DEPARTURE
91 -Sb -
Brain Service
P.O. Box 141811
Anchorage, AK 99514
TECHNICIAN
rrh,a—
q, 2
.f:: Z77 "Z
O Cash., 0 Check # O Credit Card
CC#
Authorized
Signature (Open Acct. Only) Date
OPEN ACCOUNTS ONLY na nat write u oris space!
By signing this invoice the above named account agrees to pay thi invoice based on
the following terms. Payment is due in full upon receipt of state ent. Any invoices
unpaid 30 days after statement date will be considered delinquen and account sus-
pended. Interest may be accrued at 1.5% per month. In the event at payment is not
made, all reasonable collection fees, attorneys fees, court or other Ilection costs will
be assessed as perrnitted by law.
Q0001/0001