Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T15N R1W SEC 19 LT 14
Municipality of Anchorage Page / of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ,.~'~ 9~, O/0/ PID Number: ~e: Wastewater System: D New ~Upgrade Address: /~7 ~o>//>/~', Q~v~/~/~ ABSORPTION FIELD ~ ~DeepTrench ~ Shallow Trench Q Bed ~ Mound D Other Soil Rating: Total Depth from original grade: LEGAL DESCRIPTION ~. ~ ~ws~.~. ~o. 7 Lot: Block: Subdiv~ion: Depth to pipe bo~om from odgin=l grade: Gravel depth beneath pipe - ~ ~, ? ~t. g ' ~t. 'Township:/~ IRange:/~ I Section: /, Figadded aboveor~gina, grade:o.>__// Ft. Gravellength:~. Ft. Number of lines: ~ 0istsnce be~n lines: WELL: D New ~,.~ Upgrade Gravel width: ~ Ft. /I ~ Ft. Classification (Private, A,B,C): Total Depth: ~ Total absorption area: Pipe material: ~e Drilled: StaticWater Level: Installer: Date installed: Yield:~l Pump Sot at: Ft..I C~ing Height A~ve GroundFt. TAN K SEPARATION DISTANCES ~eptic ' Q Holding ~ S.T.E.P. To Septic Abso~tion Li~ Holding ~¢/Privat~ Manufacturer: ~ Cap~ciW in gallons: From Tank Field Station Tank Sewer Lines ~c~. ~ Wel~ I ~ O / ~ ~ ~ / ~/~ ~/~ ~ ~/ Material:~ Number of Compa~ents: Su~ac~ Water P/PO 4 ~ ~M LIFT STATION Line ~' ~F' ,~,' Size in gallons: Manufacturen Foundation ~ ' ¢¢' ~/~ "Pump °n" level at: ,¢_~,,~---IHigh water alarm St: Cu~ainDrain I ~ '~ P '~' I ~/~ u~ Electrical Inspections pedormed by: Remarks: ~X/3W~I& %~ht~ ~ ~/~ BENCH ~ARK Location and Description: Assumed Elevation; Inspections pedormed by: ~/d ~ Dates: 1st o~/~ ¢¢&, 2nd Depadment of Heal h and u n go.ices approval Reviewed and approved by: ~ ,~_ ~ ~ %, ~'~Date: I0 [~ 72-013 (Rev. 9/91 ) MOA 25 Permit No. SW960 Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.0. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 545 4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: LOT 14, T15N R1W $EC.19 S 89°59'0~ E 165,00 50' EASEIIEN]' EXISTIN SEWER RDCK ' EXIgTING S 89°59'0~ E lao,s e' PiD No.: 05124111 SWING TIES 390 688 958 94.J 66.0 6'7.0 SCALE 1" = 60' [] - TEST HOLE · - MONITOR TUBE o - SEWER CLEANOUT ~ - WELL EASEMENT NEW LEACHFIELB ELEVATIDNS (NDT TB SCALE) ~ TOP DF CDNC SBNB TUBE, REAR DF ADDITION ~ AS-~;UNED ELEVATION = 100.00 ORIGINAL 09/04/96 ENGINEER'S SEAL ~,~.~...-" ,.,~'.....,- ~ ~'"':~'"'~C; ......... .ou~s A. aU~EaA ..',~ S 89°59'0' E ~65.00 ___ 5_o'__~^&E~_~NT ..... ~. ~-' ~ ........ / ~ / ~ - TEST HOLE ~ - ~ON~TOR TUBE o - SEWER CL~NOUT + - WELL ~SEMENT NO SURFACE WATER PROPOSED L~CHFIELO NO KNOWN CURTAIN DRAINS SEPTIC UPGRADE PLAN OWNER: SHAPIRO CONTRACTOR: N/A ~, :~9~ x *~{ JOBff 96-O51A/DATE: 06/26/961 SCALE 1" = 60' EAGL~ RIVER ~NGIN~ER;NO SERVICES ~ ~-~ ... c~-s~s...' ff~ ~ P.O. Box 77~4 ~ EAGLE RIVER, AK. ~577 ~ X (~07) ~4-5~S FAX: (~07) G~4-3~7 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION: DATE PERFORMED: Township, Range, Section: 7-/~-''>'' ~' ! ~ ~'~. /? 5 6 7 8 9 10 11 12 13 14 15- 16- 17- 18- 19- 20- WAS GROUND WATER ENCOUNTERED? SLOPE SITE PLAN E Depth to Water After ~ Monib~ring? Da~ iII I PERCOLATION RATE 1~' {minutes/inch) PERC HOLE DIAMETER TEST RUN SETWEEN °/' _ FT AND 7 FT PERFORMED SY: ~-'(- I '-'~ CERTIFY THAT THIS TEST WAS PERFORMED IN PAGE 1 OF MUNICIPALITY OF ANCHORAGE \~Y'C% DEPARTMENT OF HEALTH AND HUMAN SERVICES %-~%-%L~ P.O. BOX 196650, 825 "L" STREET, ROOM 502 ~'? ~'p'AN~HORAGE' ALASKA 99519-6650 ~2 ~'~P ~3 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW960171 DESIGN ENGINEER:EAGLE RIVER ENGINEERING SERVICES O~ER NAME:SHAPIRO PETER D & OWNER ADDRESS:19497 KLONDIKE CHUGIAK, AK. 99567 PARCEL ID:05124111 DATE ISSUED: 7/05/96 EXPIRATION DATE: 7/05/97 LEGAL DESCRIPTION: T15N R1W SEC 19 LT 14 LOT SIZE: 53100 (SQ. FT. NUMBER OF BEDROOMS: 5 THIS PERMIT: 5 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK /~'~R~O~a~w ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AACS0) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ISSUED BY: Eagle River Engineering ervices Louis Butera, P.E. P.O. Box 773294 (907) 694-5195 tel Eagle River, AK 99577-3294 (907) 694-3297 fax June 27, 1996 Jim Cross, P.E. Manager, On-Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Re: Lot 14, T15N R1W Section 19 Narrative & Permit Application Dear Mr. Cross: The proposed septic upgrade will have very limited impact on adjacent properties for the following reasons: 1. The surrounding lots are large, allowing sufficient room for septic sites. 2. Immediate neighboring septic systems are all +30' distance. 3. Reserve space is adequate, due to absorption capacity. 4. Drainage will not be affected and is not a major consideration in our design. If you have any questions please call our office at 694-5195. Sincerely, Louis Butera, P.E. \1996\96-051A-NAR.DOC ~ ~9°59'0~ E 165,00 50' EASEMENT / g TEST HOLE m - WON~TOR TUBE o SE~ER CL~NOUT ~ ~ELL -- -- - ~SEWENT NO SURFACE ~ATER PROPOSED L~OHFIELD NO KNOWN CURTAIN DRAINS SEPTIC UPGRADE PLAN LEGAL: LOT ~4, T~5~ R~W S~C.~9 ~2~.. .... CONTRACTOR: N~A gC:g9TH~ ".~. JOBff 96-051A DATE: o6/26/961 SCALE 1" = 60' P.O. Box 77~4 EAGLE RIVER, AK. 99577 (907) 694-5195 FAX: (907) 694-3297 ~,.~.~ Municipality o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street. Anchorage. Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: DATE PERFORMED: ~/--/ ~'-~' ~3/ Township, Range, Section: '7'/~-'~" /~ / ~ 5~.~. /? 8,_ 9- 10~- ,~-- -11 - 12- 13- 14- 15- 16- 17 18- 19 2O COMMENTS WAS GROUND WATER ENCOUNTERED? ELOPE Site PLAN A i / / IF YES, AT WHAT /~,~ DEPTH? Oeplh I~ Wala' Alter L~_y Dale: Mani~ring7 PERCOLATION RATE / c/ (m~nu~esllncn) PERC HOLE DIAMETER TEST RUN BETWEEN 5'.~'- FT AND ~'. 5" FT PERFORMED BY: I ~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIOELiNES IN EFFECT ON THIS OATE. DATE. EAGLE RIVER ENGINEERING SERVICES P.O. Box 773294 Eagle River, Alaska 99577 (907) 694-5'195 ERES Project No.: 96-051 Calculated By: LB Date: 6/20/96 Legal: LOT 14 Single Family 5 Bedroom Dwelling TEST HOLE Deep Trench Subsurface Wastewater Disposal Field Water use at 150 gallons per bedroom = 750 gallons Percolation rate = 14 minutes per inch Wastewater application rate = 0.8 gallons per day per square foot Required absorption area = 938 square feet Trench width ON) = 3 feet Gravel depth (D) = 8 feet Required length = Required absorption area / 2 / D Required length = 938 / 2 Required length = 59 feet Total Excavation Depth = 11.0 feet / 8 SINGLE FAMILY ON-SITE WORKSHEET ERES PROJECT NUMBER: 96-051 LEGAL DESCRIPTION: LOT 14 NUMBER OF BEDROOMS: 5 WATER USE PER BEDROOM: 150 PERCOLATION RATE: 14 DEPTH TO GROUNDWATER: 17 DEPTH TO IMPERMEABLE LAYER: 17 ANTICIPATED DEPTH OF COVER: 3 MOUND OR BED SYSTEM WASTEWATER APPLICATION RATE: ABSORPTION AREA REQUIREMENT: MINIMUM BED LENGTH 12 FEET WIDE BED 15 FEET WIDE BED TRENCH SYSTEM WASTEWATER APPLICATION RATE: ABSORPTION AREA REQU!REMENT: SHALLOW TRENCH OPTIONS 5 FEET WIDE TRENCH CALCULATED BY: LB GALLONS MINUTES PER INCH FEET' FEET USABLE SOIL STRATA FEET TOTAL USABLE DEPTH: USABLE SOIL STRATA DEPTH: 0.5 GALJSQ.FT 1500 SQ.FT 11 8 125 FEET 100 FEET 0.8 GAUSQ.FT 9~.5 SQ.FT DEEP TRENCH OPTIONS 3FEET WIDETRENCH EFFECTIVE REQUIRED TRENCH EFFECTIVE REQUIRED TRENCH DEPTH (FT) ENGTH (FT) DEPTH (FT) ENGTH (FT) 1 164 4 117 2 131 4.5 104 2.5 119 5 94 3 109 5.5 85 3.5 101 6 78 4 94 7 67 8 59 9 NA DESIGN SPECIFICS FIELD SYSTEM: D GRAVEL DEPTH: 8 TRENCH OR BED WIDTH: 3 LENGTH: 59 TOTAL EXCAVATION DEPTH: 11.0 FEET (B=BED, S=SHALLOWTRENCH & D=DEEP TRENCH) FEET FEET FEET SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM LEGAL: Lot 14, T15NR1WSection 19 06/26/96 GENERAL 1. The septic plan is for a single family residence only. 2. The drawing and or site plan shall be a part of this specification. 3. All materials and workmanship shall meet the Anchorage Department of Health requirements. 4. All soil tests are advisory to the design and are to be verified or modified in the field by the engineer. 5. All excavations and depths are advisory and are to be verified in the field by the contractor to meet Municipality of Anchorage requirements. 6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any adjacent multi-family wells. 7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer approval. 8. It is always recommended that a surveyor locate the nearest lot line position and the location of any easements. SEPTIC TANK & LEACHPIT 1. The existing septic tank shall be pumped, and then either crushed and buried on- site or appropriately disposed of off-site. 2. The replacement tank shall be 1,500 gallon MOA approved septic tank, and shall be placed in the location shown on the site plan. 3. The existing pit shall be pumped, crushed and filled. TRENCH 1. The trench is to follow the natural land contour to maintain uniform total depth of the trench bottom. 2. The bottom of the trench shall be level, plus or minus 1.5". 3. The total depth of the trench excavation is not to exceed I 1' at any point. 4. The trench gravel is to be covered with typar fabric material. 5. Soil or combination of soil and extruded board insulation to a depth of 3' or equivalent is to be placed over the leachfield. 6. The area over the trench is to be finish graded to prevent ponding of surface water runoff. 7. The septic tank and leachfield must not be closer than 100' to any existing private well, 150' to any Class "C" well, or 200 feet to any community well. RECOMMENDED LEACHFIELD DIMENSIONS: TOTAL DEPTH = 11' GRAVEL DEPTH = 8' under pipe, 2" over pipe TRENCH LENGTH = 59' TRENCH WIDTH = 3' SOIL RATING = 0.8 GPD/ft2 BEDROOM CAPACITY = 5 SEPTIC TANK = 1,500 gallons Twenty-four (24) hours notice required for all inspections. \1996\96-051a-spc.doc GP'~'~TER ANCHORAGE AREA BORO!~H HEALTH DEPARTMENT 327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATION ~/r'¢ ~/.~'~ ~ SEPTIC TANK: MAILING ADDRESS ~-/~/ //~T ~'~Z C J~'.~/~/~ PHONE °,STANCE FROM WELL rD' MATER,A, / LIQUID CAPACITY /~/D GALLONS. INSIDE LENGTH NUMBER OF / COMPARTMENTS ~ ~l/q T~ L,QU~D INSIDE WIDTH DEPTH SEEPAGE SYSTEM: NUMBER OF PITS NEAREST LOT LINE ~/-~ J~ SEEPAGE PIT: OUTSIDE DIAMETER OR WIDTH , LENGTH , DEPTH DISTANCE FROM WELL//>~) /'~~4 iU~)~ ~ BUILDING FOUNDATION TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ~ '~ SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL TOTAL LENGTH _ _ , FOUNDATION //~T'-L-OI LIh:l~ , OF LINES DISTAN~ TRENCH WIDTH ~. IN. TOTAL EFFECTIVtC SQ. FT. LENGTH OF EACH LINE DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE WELL: TYPE /'a[~'/~O'~/j a/Y;//~),~/ DEPTH NEAREST LOT LINE . SEWER LINE DISTANCE FROM WATER · BUILDING FOUNDATION. SAMPLE , NEAREST SEPTIC SEEPAGE OTHER TANK SYSTEM , CESSPOOl ~ SOURCES DISTANCES: DIAG ~AM OF SYSTEM DATE / GYM,ER ANCHORAGE AREA BOROI'-~k't ", HEALTH DEPARTMENT 327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-251 N? 295 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: DISTANCE FROM WELl. ~C':" ~'~,(t'~', j~ c~] _MATERIAL_ ICIUID CAPACITY ./('~( ~,c? GALLONS. INSIDE LENGTH NUMBER OF COMPARTMENTS ;1~, /, ,/:) ;,'L' LIQU~D INSIDE WIDTH DEPTH__ SEEPAGE SYSTEM: SEEPAGE PIT: qUM3ER OF PITS_ J OUTSIDE DIAMETER DISTANCE FROM WELL /" ] (Ct ~J~ i~, ~'LJ , BUILDING FOUNDATION TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) Z~ ~ . SQ. FT, rILE DRAIN FIELD: )ISTANCE FROM WELL '4UMBER OF Lli~ES~ '~BSORPTION AREA FOUNDATION. DISIANCE BETWEEN LINES_ SQ. FT. LENGTH OF EACH LINE , NEAREST LOT LINE , TRENCH WIDTH )EPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE. TOTAL LENGTH . OF LINES IN. TOTAL EFFECTIVE IN. ABOVE TILE ~ELL: TYPE ' ~-? '' r :"' ':,/ DEPTH NEAREST SEPTIC O] LINE , SEWER LINE ., TANK DISTANCE FROM WATER .. BUILDING FOUNDATION. SAMPLE SEEPAGE SYSTEM CESSPOOl NEAREST OTHER SOURCES )I-C, TANCES: DIAGRAM ~DF SYSTEM !/ t,,3 e' 'i >~-;-, ' · DAlE ' ~ APPROVED " ' .- /:. ' .- / Location Sketch ,~,~t Drop Propo~,,ed ,-hsta~,±a?lon: ~eep, age [-'~. ¢ Drain l~JeJ.d Data y ~ ~ . Certified ~ Municipality ®f Anchorage On -Site Water and Wastewater Programh`' , (907) 343-7904 ` 5 A � Certificate of On -Site Systems Approval Parcel I.D. 051-241-11 1. GENERAL INFORMATION: Complete legal description T15N: R1W SECTION 19 LOT 14 Expiration Date: �- 3 - 2-©z I Location (site address) 19497 KLONDIKE DRIVE CHUGIAK AK 99577 Current Property owner(s) KEVIN & YVETTE O'CONNOR Day phone 727-9193 Mailing address 19497 KLONDIKE DRIVE CHUGIAK AK 99577 Real Estate Agent LAURA TEMPLE W/ UNITY HOME GROUP Day phone 854-8625 2. TYPE OF DWELLING: X Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 5- 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver/Variance request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ � 12 50 Co U In Waiver Fee $ _ Date of Payment 1 Z -1 - 2/D Date of Payment Receipt Number naZ6 G Receipt Number COSA # 0!5c wi6 G I Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road Suite 101- Anchorage Alaska 99507 Engineer's Printed Name:. Jeffrey A. Garness Date: In conducling this evaluation. GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the datels of the evaluation, Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend upon a variety of variables, including but not limited to, soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the systemis; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail to perform adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. y A. Carrllh-9: #AECC884 6. DSD SIGNATURE System #1 Approved for bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for O�pri J`� ON-SITE `y bedrooms, with the follo�gif� sti�}p,�ieS;gND 0151 �m WAST ---V ATER ?^ f fi F OG AM v t Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Tile Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist y Septic System Advisory __ Well Flow Advisory COSA blue shee:-10-10-12.uoc Nitrate Advisory Arsenic Advisory Other � e e ! aMy �%Si01/1 Legal Description: T1 5N, R1 W, SECTION 19, LOT 14 Parcel ID: 051-241-11 If more than 1 septic system on lot: COSA Checklist # of Structure served by this system A. WELL DATA *PER 2005 COSA- WELL 51' DEEP PER 1976 MOA RECORDS ❑ Well log is filed with Onsite (or attached) Date drilled 1970(?) Total depth *49.5 ft Cased to *49.5 ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) 18+ in. Date of flow test for COSA 912120 Well production at time of test ***4+1- gpm Water storage tank volume N/A gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate 1.2 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by GEG,LTD. Date of Sample 9/2/20 Static water level at beginning of test **30.7 ft Comments **ON 11/17/2020. "ON 9/2/2020 -PUMPED 1787 GALLONS IN 439 MINUTES, B. TANK DATAFT STATION Age of tank(s) 24 years ❑ Requir aintenance completed Tank type/material STEEL Ag>station yea Measured operating fluid level in septic tank 50" LifStandpipes/foundation cleanout per record drawing Co Date of pumping 6/11/2020 D. ABSORPTION FIELD DATA DEEP TRENCH (MT1 / MT2) Which system tested (date installed) 8/29-913/1996 Adequacy test date "913/20 ❑ ALL standpipes present per record drawing Results Pass For **5 bedrooms Total measured depth from grade 11.8 ft (max) Fluid depth prior to test "`86.25 / 86 inches Measured depth to pipe invert from grade *3.4 ft (min) Water added **723gal El N/A - pressurized field FE-1monitortubes go to bottom of effective. If not, state New depth —101 / 100.75 inches 1162 depth into effective Elapsed time min * ❑ Code -required soil cover over field Final fluid depth **89.5 / 89.25 inches ❑ System presoaked Absorption rate *'750+ 91P (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) none date of test) Gallons introduced **1787 gallons If yes, enter date Comments/Deficiencies: 'SEE ATTACHED STATEMENT FROM OWNER. • SEE ATTACHED EXPLANATION LETTER REGARDING ADEQAUCY TEST. ***AT TOP OF LATERAL. RECOMMEND MOA ADVISORY NOTICE. COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ED Yes if No Community Sewer Manhole/Cleanout > 100' Surface Water > 100' ril Yes if No ft Q Yes if No ft Neighboring Tank > 100' P/ Yes if No ft Private Sewer/Septic Line > 25'✓M Yes if No ft Absorption Field on Lot > 100' Q Yes if No ft Holding Tank > 100' Yes if No ft Neighboring Absorption Fields > 100' Water Service Line > 10' 0 Yes Animal Containment > 50' Yes _ if No ft Q Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' 0 Yes if No ft 0 Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ED Yes if No ft Surface Water > 100' [✓ Yes if No ft Property Line > 5' M✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10' Absorption Field > 5' ❑✓ Yes if No ft Private Wells > 100' 0 Yes if No ft Water Main > 10' ❑✓ Yes if No ft Community Wells > 200' 0 Yes if No ft Water Service Line > 10' 0 Yes if No ft. If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ✓M Yes if No ft If absorption field is under driveway comment below Property Line > 10' ✓0 Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells > 100' Yes if No ft Water Service Line > 10' M Yes if No ft. Community Wells > 200' Yes if No ft Surface Water > 100' ✓] Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet #AECC884 November 20, 2020 Municipality of Anchorage Development Services On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, Alaska 99507 Phone: (907) 343-7904 ................ 7 .............. Y; A Reference: Septic Adequacy Test Explanation for T15N, R1 W, Section 19, Lot 14 To whom it may concern: The existing septic system on the referenced property consists of a 1,5000 -gallon steel tank and a deep trench drainfield that is 60 feet long by 3 feet wide with 8 feet of effective (96"). According to the homeowner questionnaire that the owner completed, the house has been vacant since 3/17/2019. According to the pumping receipt, the septic tank was pumped on June 11, 2020. During our initial site visit on 9/2/2020, we noted the septic tank was working at normal level and there was 52.25" of standing liquid in the west monitoring tube (MTI) and 51.75" of standing liquid in the east monitoring tube (MT2). We also noted a small amount of water was dribbling in the bottom of one of the sewer lines exiting the house. This may be due to a toilet flapper not sealing correctly or some other internal plumbing leak. Based upon an email from the owner's representative, the most recent usage on the septic system was during the Spring of 2020, but no usage was mentioned after the June 11, 2020 septic pumping. In short, the plumbing leak appears to be significant enough to fill the 1,500 -gallon septic tank and possibly influence the liquid level in the drainfield. As required by the MOA (for a vacant residence), we performed a presoak on the drainfield. On 9/2/2020, we added a total of 1,787 gallon of water to the drainfield which brought the liquid level in the drainfield to the invert of the cleanouts (97.25" in 'MT1 and 97" in MT2). On 9/3/2020, we returned to the property and found the liquid depth of the drainfield to be at 86.25" in MT1 and 86" in MT2. We then added an additional 723 gallons to the drainfield, which brought the liquid level in the drainfield to the top of the distribution line (filled to 100% capacity with 101" in MT1 and 100.75" in MT2 — 4" of standing liquid in both cleanouts). After stopping the introduction of water to the drainfield, the system was allowed to recover for 310 minutes during which time the liquid levels dropped to 96.25" in MTI and 96" in MT2. We performed a second recovery reading the following day (914/20), 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com Page 2 of 2 1162 minutes after water was stopped being introduced, and found the liquid depth in the drainfield to be 89.5" in MT1 and 89" in MT2. Based upon our calculations and some other readings taken during the septic test,. we calculated that the system marginally absorbs 750 gpd, as required for a 5 -bedroom residence. We would also like to note that the septic system may be approaching the end of its useful life expectancy due to the age of the steel septic tank and the marginally passing results for the drainfield. It is our recommendation that the MOA issue an advisory notice. Please do not hesitate to call us at 337-6179 if you require further information. Thank you for your assistance. Sincerely,, f 9" In_ Jeffrey/ A Garness, P.E., M.S. President _} .f 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www,garnessengineering.com -2Vz www.muni.org/onsite Septic System Absorption Field Advisory Certificate of On -Site Systems Approval # OSC201661 Subdivision: T15N R1W Sec 19, Lot: 14 During the absorption field adequacy test, 86.25 inches of standing water was observed in the absorption field. This indicates approximately 90+% of the absorption area is inundated. Although this system passed the adequacy test, the remaining life expectancy may be limited. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. Ra. DEVELOPMENT SERVICES DEPARTMENT On -Site Water and Wastewater Section ` b. www.muni.org/onsite Septic Tank Advisory Certificate of On -Site Systems Approval #OSC 201661 Subdivision: T15N R1W Sec 19 Lot 14 907-343-7904 Fax: 343-7997 Starting at 20 years of age the MOA issues Advisory's for steel septic tanks. The septic tank for this property is 24 years old. Typical replacement costs range from $8,000 to $11,000 This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of what the metal of a 20 year old steel tank MAY look like. Ma�hng Address P O Box 196650 * Anchorage,SAlaska 99519 6650 *wRE ww muni org :c40{ t�1 Z m m z w �2 F- W o p Q : 6 x a � C U a w �.' > i� Z zw ¢ �X z I a o u. i �' yr W Z° W a N S' > X o F- / '. T ..x Ul L' i i f- w w W W 0 ;J j GREATER ANCHORAGE AREA BOROUGH \~,"~j ~! I1~'// Department of Environmental Quality ~~-' 3330 "C" Street, Anchorage, Alaska 99503 274-4561 ~m~O~ Date Received May. _6f 1976 Lo ~¥l~) Time of Inspection /~,'~ ~,~. ~3~i~ qo ~ '~--~ll~ Date of Inspection ~ )/~NDIVIDUAL SEWERFoR & WATER FACILITIES 1. Approval requested by: Smiley's Realty Mailing Address: s Box 1086, Eagle River 2. Property Owner: Henry Perkins Mailing Address: Phone: 694-2114 - Phone: 688-2505 Legal Description: Lot 14 Section 19 T15N R1W Location: Klendike Street Rick Type of facility to be inspected Well Data: A. Type Individual C. Construction Sewage Disposal System: A. Installed C. Septic Tank: D. Seepage Pit: E. Disposal Field: approx. 1. Size 1. Absorption Area To~al length of lines Distances: A. Well to: Septic tank Nearest lot line B. Foundation to septic tank Single Family No. of bedrooms 5 B. Depth 51' D. Bacterial Analysis '69 B. Installer 2..Manufacturer , Absorption area , Other contamination , Absorption area C. Absorption area to nearest lot line 2. Material ., Sewer Lines __, EQ-034 (1/74) Page 1 of two pages GREATER ANCHORAGE AREA BOROUGH FNVIRONMISN'[,qLi'~Oi'ZcflO~ Department of Environmental Quality 3330 "C" St., Anchorage, Alaska 99503 REQUEST FOR APPROVAL OF J'<L,. ........ INDIVIDUAL SEWER & WATER FACILITIES 1. Type of Inspection: CMRO VA FHA CONV 2. Property Owner: '~o._~o~ ~t.~,..~:~_~ Mai.ling Address: Day Phone ~-~2~C~ 3. Name of Buyer: ~'>,~Z..~--- ' Mailing Address: ~ Day Phone 4. Name of Lending InstitUtion: Mailing Address: ~'~ Phone 5. Name of Realtor or.Agent: ~-~-~/~ E~o.~[~--~.~_~ ' ~ C~~' p~ Mailing Address: ~~g [~. .~,~/~ hone o Legal Description: .~ Type of Facility to be inspected: Water Supply Type of Supply: Public Utility Individual If Individual, number of dwellings presently served ! If Individual, depth of well ~l 9. Sewage Disposal SYstem Type of System: Public Utility Individual (on-site) \ If Individual,. date of installation r_~o,rx% ~_~ Eq-037 (]/74) ~5age 2 of two pages - Req ~st for Approval of Individual SX-'~r & Water Facilities ~eg~l-D~scription Lot 14 Section 19 T15N R1W Comments ~,~ ~/~ ~ · Approved Approval iValid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ-034 (1/74) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION 825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL ENGINEERING DIVISION Telephone 2'64-4720 Allers ~,~?.? /~ REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROPERTY OWNER PHONE MAI LING ADDRES ~,..,~.. PROPERTY R NT (If [llfferent from above) - 2, BUYER PHONE Would like to have us look at it and document it to see w at is MAILING ADDRESS there and what needs to be done with it. 3, LENDING INSTITUTION PHONE MAILING ADDRESS 4. REALTOR/AGENT I PHONE MAILING ADDRESS 5. LEGAL DESCRIPTION T15N R1W Section 19 Lot 14 STREET LOCATION 190 Klondike Road, S. 6. TYPE OF RESIDENCE green J~ SINGLE FAMILY [] MULTIPLE FAMILY Birchwood Loop to the 2nd street on the ~-to z-story house NUMBER OF BEDROOMS [] One [] Four [] Other__ [] Two [] Five ~ Three [] Six 7. WATER SUPPLY ~ INDIVIDUAL* + ATTACH WELL LOG. A well Icg is required for all wells drilled [] COMMUNITY since June 1975. For wails drilled prior to that date, give well [] PUBLIC UTI LITY depth (attach Icg if available.) 8. SEWAGE DISPOSAL SYSTEM ~ iNDiViDUAL/ON_SiTE~ [~D PUBLIC UTILITY **If individual/on-site, give installation date If system is over two (2} years old an adequacy test is required by this Department. NOTE: T~IE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. ~,,~--~ 2 -010 (3/78') 'rills SIDE FOR OFFICIAL USE ONL ' DATE RECEIVED INSPECTION APPOINTMENTS TIME . ?J:D TIME TIME \ DATE ~ ~,'1.~ 5 ~' DATE DATE NSP E-"CTOR INSPECTOR INSPECTOR DIRECTIONS: 1, TYPE OF RESIDENCE NUMBER OF BEDROOMS ~ SINGLE FAMILY [] ONE [~ THREE [] FIVE [] OTHER ~] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY '~3/ INDIVIDUAL DEPTH OF WELL E] COMMUNITY DATE DRILLED E] PUBLIC UTILITY Coonection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER "~NDIVI DUAL/ON -SITE DATE INSTALLED ~J PUB LIC UTILITY Connection Verified INSTALLER ~eptic Tank or [] Holding Tank Size: ~OO¢) If Tank is homemade SOILS RATING give dimensions: TYPE; OF TANK ~ MANUFACTURER TOTAL AESOR~ON AREA MATERIAL 4. DISTANCES Septic/Holding Tank A~~ Sewer Line Nearest Lot Line · WELLTO: Absorption Area to nearest Lot Line 5, COMMENTS [~APPROVED FOR ~ BEDROOMS E3 CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED DATE BY {Ti -'3? LEGAL DESCRIPTION 72-010 (Rev. 3/78) '