Loading...
HomeMy WebLinkAboutT15N R2W SEC 25 LT 31Onsite T15N R2W Sec.25 Lot 31 #051-281-03 Municipality of Anchorage Community Development Department Page 1 of 2 On -Site Water and Wastewater Program 4700 Elmore St. - P.O. Box 196650 Anchorage, AK 99519-6650 - http://www.muni.org/onsite - (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181071 PID Number: 051-281-03 E] New 0 Upgrade Name: PAMELA HODGSON ABSORPTION FIELD El Deep Trench [Z] Shallow Trench El Bed [] Mound Address 16128 CARLISLE ST E] Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 1.0 GPD/SF 8 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 5.5 Ft. Gravel depth beneath pipe 2.5 Ft. Subdivision Block Lot 31 Fill added above original grade 0 Ft. Gravel length 58 Ft, Township Range Section 15N 2W 25 Gravel width 5 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To From septic Tank Absorption Field Lift Station I Holding Tank Sewer Line Total absorption area 453 F t2 Number of trenches 1 Dist. between trenches Ft. Well 107.2 127.5 N/A N/A 34.3 TANK El Septic El S.T.E.P. E] Holding El Other Manufacturer Anchorage Tank Capacity 1 1000 Gal, Surface Water 100+ 100+ N/A N/A Material Number of compartments Lot Line 27.4 2.0 N/A N/A NA STEEL 2 Foundation 63.9 81.5 N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain 1 50+ 50+ N/A N/A� Gal. Remarks ITZ Pump on level at in. Pump off level at in. High water alarm at in. Pump make and model Electrical Inspections performed by Installer PIPE MATERIAL House totank 3034 Tank to 3034 d JR'S eNTERPRISE Drainfield 3034 CO/MT 3034 Inspector Pannone Engineering Services BENCHMARK (Assumed elevation) 265 ft Inspection �1 �d dates: 1 6/22/18 2 6/23/18 3`d6/23/18 4 ih 7/16/18 Location and description SE BOTTOM HOUSE TRIM COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional Approval: Date Of" laACw" .4, Approved Lx;ug Date tieve . n .. 81 Aaw n inspection Neport_i- i­iz.aoc ,-DESIGN PARAMETERS �_AA B Tl 23.2 38.9 T2 PRIMARY SEPTIC SYSTEM Wmz z 56 0 M z O.G./ F.D. v NO. BEDROOM: 3 (450 gpd) 5E 0 265 n n nn _3 63.9 TANK SIZE: 1000g 47.5 59.0 PERC RATE: 0.7 MPI BARN SOIL RATING: 1 GPD/SF AREA ROD: 450 SF SYS. TYPE: WIDE TRENCH 2.5'ED RF: 0.64 -77 b ui EF 3: MIN LENGTH: 57.6 LF . - USED: A uo 0 Ln 58 LFx5'Wx2.5' E.D., 8.0' TD3w < z -7 TOTAL AREA: 453 SF 38R > ry 1- ui HOUSE LJj bi WELL cf) Lj U) www > 3: Of 0 GARAGE Lf) Z LO ION TION 4- FOUNDATION 0 < u 0 CLEAN-OUT 1 0`7. 1 0 0 DECOMMISSIONED EXISTING 1 ,./SEPTIC TANK PER MOA CODE INSTALLED 1000g SEPTIC T, PIP tv DECK Tl A DOUBLE CLEAN OUT AFTER VV' T2 z EXISTING DRAIN FIELD IN FAILURE 11.5 UNABLE TO REUSE AS RESERVE eC2 ABANDONED IN PLACE' - — 2.0 M 2 — -------- . . . . . . INSTALLED UPGRADED DRAIN FIELDTH-1 o TH-2 58LF x 5'W x 2.5*ED x 8.0'TD Cl M WITH CLEAN OUT AND MONITOR TUBE AT ENDS 7- 1000g SEPTIC TANK PROFILE SCALE: NTS FILTER FABRIC 81 z 4" 0 DRAIN PIPE z D.C./ F.C. 0 DRAIN ROCK S' A80VE PIPE INV m U 265 i n EST HOLE I I OR I Gm/ 4— SM 4 2,5* DRAIN ROCK DRY: SP/ 11/10/2018 SM A B Tl 23.2 38.9 T2 20.7 Wmz z 56 0 M z O.G./ F.D. v 91-1 5E 0 265 n n nn _3 1000g SEPTIC TANK PROFILE SCALE: NTS FILTER FABRIC 81 z 4" 0 DRAIN PIPE z D.C./ F.C. 0 DRAIN ROCK S' A80VE PIPE INV m U 265 i n EST HOLE I I OR I Gm/ 4— SM 4 2,5* DRAIN ROCK DRY: SP/ 11/10/2018 SM TEST HOLE 2 SP/ SM 14 NI 14 N DATE PERFORMED: DATE PERFORMED: 71/01/16 6/22/18 NOTES:Date RECORD DRAWING PANNONE ENG SVC, LLC OF. k_q 7/11/2018 P.O. BOX 100217 ANCHORAGE, AK 99510 REVI 181102 PHONE (907) 272-8218 FAX (907) 272-8211 Scale G. 1"=50' .... .. U P.I.D. NO T15N, R2W, Sec 25, LOT 31. ...... =-281-03 PAMELA HODGSONeven none PERMIT NO. DRAWN ACP CE 8149 16128 CARLISLE STREET OSP161334 PLAN EAGLE RIVER, AK 99577 Sheet klk�, FROFESSI6 a 2 OF 3 A B Tl 23.2 38.9 T2 20.7 35.5 DCO 20.5 34.4 Cl 21.2 21.2 M1 20.0 21.5 C2 51.8 63.9 M2 47.5 59.0 TEST HOLE 2 SP/ SM 14 NI 14 N DATE PERFORMED: DATE PERFORMED: 71/01/16 6/22/18 NOTES:Date RECORD DRAWING PANNONE ENG SVC, LLC OF. k_q 7/11/2018 P.O. BOX 100217 ANCHORAGE, AK 99510 REVI 181102 PHONE (907) 272-8218 FAX (907) 272-8211 Scale G. 1"=50' .... .. U P.I.D. NO T15N, R2W, Sec 25, LOT 31. ...... =-281-03 PAMELA HODGSONeven none PERMIT NO. DRAWN ACP CE 8149 16128 CARLISLE STREET OSP161334 PLAN EAGLE RIVER, AK 99577 Sheet klk�, FROFESSI6 a 2 OF 3 SOILS LOG - PERCOLATION TEST TEST HOLE 2 SLOPE SI PLAN OR ORGANICS 1 � 1 1 2 GM/ SILTY GRAVEL \� SM AND SAND 3 P— / I I 4 265 I 265 DECOMMISSIONED EXISTIN ( SEPTIC TANK PER MOA CO 5 265 GRAVELLY SAND / ss INSTALLED 1000 SEPTI 6 SP/ WITH SILT x TH DECK / � DOUBLE CLEAN OUT AFT LARGE SM COBBLES \ N1 i PRESENT I 8 v rl B I � B g 1 FAILURE I ESERVE 10 11 DED DRAIN FIELD TH-21 TH-1 12 ED x 8.0'TD ND MONITOR 13 WAS GROUND WATER SLOPE 14 BOH ENCOUNTERED? N 15 IF YES, AT WHAT TH DEPTH? x 16 17 DEPTH TO WATER AFTER MONITORING? 18 DATE: 19 DATE PERFORMED: 6/22/18 SOIL TEST RESULTS/ANALYSIS • PERCOLATION RATE <1 (min/inch) (Hydrologic Soils Group: HSG A) • PERC HOLE DIAMETER 6" • TEST RUN BETWEEN 4 FT AND 5 FT. • TEST RUN FOR OVER AN HOUR, LAST THREE READINGS PROVIDED. COMMENTS: Test hole excavated by ALASKA DIVERS.Test Hole was NOT required to be presoaked before Perc test due to sandy material (Table 3-8, Para.3, EPA Design Manual). PERFORMED BY: Joseph Lawendowski. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT �OTN7�TTHE DATE OF THIS TEST. NOTESRECORD DRAWING' PANNONE ENG SVC, LLC ; - pF q�\ill Date 6 P.O. BOX 102954 ANCHORAGE, AK 99510 Scale PHONE (907) 272-8218 FAX (907) 272-8211 �* 49 TH *�� NTs • • % P.I.D. NO T15N, R2W, Sec 25, LOT 31 ...... .. .. =281-03 PAMELA HODGSON Steven R. Pannone PERMIT NO. 16128 CARLISLE STREET C�E�81�49/\��// OSP161334 SOILS LOG EAGLE RIVER, AK 99577 ��1�`FPRp�'g$0i�y"' Sheet 3e0F 3 READING DATE NET TIME WATER LEVEL READING NET DROP �� MMPI) 1 22JUN1B 5.900' 2 4 MIN 11.233' 5.33' 0.75 3 5.900' 4 4 MIN 11.455' 5.55' 0.72 5 5.900' 6 4 MIN 11.425' 5.55' 0.72 No"P""r" MUNICIPALITY OF ANCHORAGE On-Site Water&Wastewater Program • ;; S C. 1 PO Box 196650 4700 Elmore Road — Ai Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 ,, \ �! http:/lwww.muni.org/onsite Deparunc•nt 4,y C HOH On-Site Wastewater Disposal System Permit Permit Number: OSP181071 Effective Date: 5/2/2018 Work Type: Septic Renewal Expiration Date: 5/2/2019 Tax Code Number: 05128103000 Site Legal Address: T15N R2W SEC 25 LT 31 G:0753 Site Mailing Address: 16128 CARLISLE ST, Eagle River Owner: HODGSON PAMELA J Lot Size in Sq Ft: 92400 Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 3 This permit is for the construction of: D Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: The entire proposed subsurface disposal field is not within a 30 foot radius of a percolation test. An additional percolation test is required prior to construction of septic field, with stamped and signed results submitted with as-built inspection report. If the results require a design change, construction of the system will stop pending On- site review and approval. • � 5 4 S Received By: 491410 Date: Issued By: l�.�l}�,�_5� C9' 41, Date: 5111g vIDb78970 ii MUNICIPALITY OF ANCHORAGE ,� -�''�'i7'":l (�. MAY ` 18 Community Development Department Phone: 90'.4'3-7904 Development Services Division Fax: 90 ' , '-7997 s, On-Site Water& Wastewater Program /oa 6 8 L s 5� ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 051-281-03 Property owner(s) Hodgson, Pamela Day phone Mailing address 11723 Old Glenn Hwy Ste. 210 Eagle River, AK 99577 Site address 16128 Carlisle Street Legal description (Sub'd., Block& Lot) Lot 31 Legal description (Township, Range & Section) T15N R2W Sec 25 Lot Size 92,400 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field x❑ Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ❑X Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal NMultiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Mu . '•- Cr- a illils t I Aril " Aiiii . /j ign.t ''o pro:r o J"authorizedcii t) Permit/Rush Fees: $ NO Waiver Fees: Date of Payment: 5101/7 Date of Payment: Receipt Number: 6I Receipt Number: Permit No. Oc3P/F/oW Waiver No. Permit App_:- ::..:c Pannone Engineering Services «c Steven R. Pannone, Principal Registered Professional Engineer E-mail:steve@panengak.com May 1, 2018 Subject: Expired On-Site Water and Wastewater Permit Permit Renewal Request Permit Number: OSP161334 Legal Description: T15N R2W Sec 25 Lot 31 This is a request to renew the permit for the above mentioned lot. All site conditions remain the same. The construction still will not affect the health, safety, or development of the surrounding lots. Sincerely, , 3502 Steven R. Pannone, P.E. Owner/Civil Engineer Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 On -Site Wastewater Disposal System Permit Permit Number: OSP161334 Tax Code Number: 05128103000 Work Type: Septic Permit Effective Dates: December Upgrade 16, 2016 to December 16, 2017 Design Engineer: PANNONE ENGINEERING SERVICES Subdivision: T15N R2W SEC 25 Site Legal Address: T15N R2W SEC 25 LT 31 G:0753 Owner/Address: HODGSON PAMELA J 11723 OLD GLENN HWY STE 210 EAGLE RIVER AK 995777750 Site Mailing Address: 16128 CARLISLE ST, Eagle River This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank Lot Size in Sq Ft: 92400 Total Bedrooms: 3 N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The entire proposed subsurface disposal field is not within a 30 foot radius of a percolation test. An additional percolation test is required prior to construction of septic field, with stamped and signed results submitted with as -built inspection report. If the results require a design change, construction of the system will stop pending On-site review and approval. Received Issued By By: Date: ���9boIit Date: %6 0701 cnf MUNICIPALITY OF ANCHORAGE ' Development Services Department p, ; On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Drlririmcnt Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade 16, 2016 to December 16, 2017 Design Engineer: PANNONE ENGINEERING SERVICES Subdivision: T15N R2W SEC 25 Site Legal Address: T15N R2W SEC 25 LT 31 G:0753 Owner/Address: HODGSON PAMELA J 11723 OLD GLENN HWY STE 210 EAGLE RIVER AK 995777750 Site Mailing Address: 16128 CARLISLE ST, Eagle River This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank Lot Size in Sq Ft: 92400 Total Bedrooms: 3 N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The entire proposed subsurface disposal field is not within a 30 foot radius of a percolation test. An additional percolation test is required prior to construction of septic field, with stamped and signed results submitted with as -built inspection report. If the results require a design change, construction of the system will stop pending On-site review and approval. Received Issued By By: Date: ���9boIit Date: %6 0701 MunicipaRity of Anchorage P.O. Box 196650 0 4700 Elmore Road Anchorage Alaska 99519-6650 0 (907) 343-7904 0 Fax (907) 343-7997 http:/Ivvww.muni.org/Onsite Development Services Division On -Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV161137 COSA#: Permit#:OSP161334 PID#: 051-281-03 Legal Description: T15N R2W Section 25 Lot 31 Engineer: Pannone Engineering Services Applicant: Pamela Hodgson Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 2.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ® The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ❑ Adjacent properties are not affected by this waiver. ............................................................................... Waiver is Granted: X Waiver is not Granted: Date: i Z /f �/a 016 Approved by: 44r� ( 1yLe"I Name of Reviewer ............................................................................ **** VARIANCE/WAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ®� NO`J 14 2016 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 051-281-03 Property owner(s) Pamela Hodgson Day phone Mailing address 11723 Old Glenn Hwy., Ste 210, Eagle River, AK 99577 Site address 16128 Carlisle Street Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) T1 5N, R2W, Sec 25, Lot 31 Lot Size 92,400 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (2 all that apply) - Absorption Field ❑X Initial ❑ Single Family (SF) (w/wo ADU) Septic Tank 19 Upgrade N Duplex (D) Holding Tank F­1Renewal El Multiple Dwellings Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Drainfield to Lot Line Dis tance: 2 I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) ❑iC e poe Permit/Rush Fees: S 6 I�� Waiver Fees: Date of Payment: Date of Payment: l l I N /I b Receipt Number: 2n-711 3 Receipt Number: 2o71( -3 Permit No. 0S('1 C 13-3-I Waiver No. 0S; V 1(_ (1� % Permit App_.; : : L..k Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve(c@panenRak.com 7 December 2016 Subject: T15N, R2W, Sec 25, Lot 31 - - Septic System Upgrade Permit Request Design Narrative This is a design narrative for a permit to install an upgrade septic system to be issued for this property. The proposed system will serve an existing three-bedroom (3BR) dwelling. Currently the lot is developed. This lot and the surrounding lots are served by private wells. The well on this lot is over 100' from the system, and there are no wells on the surrounding lots within 200' of this system. The existing drain field is in failure and this permit will be to install an upgrade system. The septic tank will be verified and will be decommissioned per code if it is found to be leaking and a new 1000 - gallon septic tank will be installed. 1. Soils. One test hole was performed by PES in November of 2016, and groundwater was monitored for at least seven days. Ground water was not observed at a depth of 14.0' below the surface in the test hole monitor tubes in November of 2016. Bedrock was not encountered in the test hole. Based on the results of the percolation tests and overall soils appearance; an application rate of 1.2 gallons/day/square feet was used for a conventional wastewater system in the area of the test hole. 2. Soil Absorption System Design a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography:The proposed system will be placed to the south of the existing house. The area slopes generally from north to south at approximately less than 1%-2%. There are no steep slopes in the vicinity of the septic system. The proposed installation will not affect the future development of the surrounding or existing lots. If you have any questions or concerns, please contact me at 272-8218. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve(a)panengak.com November 11, 2016 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 S. Bragaw Street P 0 Box 196650 Anchorage, Alaska 99519-6650 Subject: T15N, R2W, Sec 25, Lot 31 Lot Line Waiver Request Ladies and Gentlemen: We request a waiver to two feet (2') to the lot -line. Due to the well radius and the location of the existing septic and gravity flow restrainst the field must be located in the space between the existing field and the lot line. Granting this waiver is not likely to affect the health and safety of this lot or the surrounding lots now or in the future. If you have any questions or concerns, please contact me at 907.272.8218. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 50' R.O.W. RESERVE M BARN � T(E) ELL (E) DRAIN FIELD (E) IN FAILURE 4 RE -USE AS RESERVE PGRADE DRAIN FIELD (P) XLF x 5W x 25'ED-x 8.O'TD WITH CLEAN-OUT AND MONITOR TUBE AT EACH END SEPTIC AREA (E) GARAGE 4.8 TH— 1 til/M M M \M NOTES: PANNONE ENG SVC, LLC FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 T15N, R2W, Sec 25, LOT 3' PAMELA HODGSON 16128 CARLISLE STREET PLAN EAGLE RIVER, AK 99577 o N� T 0 1. .� DESIGN PARAMETERS PRIMARY SEPTIC SYSTEM NO. BEDROOM. 3 (450 gpd) TANK SIZE. 1000g PERC RATE- 0.7 _MPI SOIL RATING: 1 GPD/SF AREA ROD. 450 SF SYS. TYPE. WIDE TRENCH 2 5 ED RF:' 0.64 MIN LENGTH: 57.6 LF USE. 58 LFx5'Wx2.5' E.D., 8.0' TD TOTAL AREA. 453 SF of A(gsl�) *: 49 M-7 Steve RC Par1n�F' PP,-. CE 8149 xe, Date 2/15/2016 Scale C=50' P.I.D. NO 051-281-03 'ERMIT N0. OSP161334 Sheet 1 OF 3 FOUNDATION \CLEAN-OUT 1j) VERIFY CONDITION OF 10008 SEPTIC TANK (E) IF FOUND TO BE LEAKING REPLACE WITH 1000g SEPTIC TANK (P; 0' INSTALL DOUBLE CLEAN OUT AND DIVERTERI VALVE W- DRAIN FIELD (E) IN FAILURE 4 RE -USE AS RESERVE PGRADE DRAIN FIELD (P) XLF x 5W x 25'ED-x 8.O'TD WITH CLEAN-OUT AND MONITOR TUBE AT EACH END SEPTIC AREA (E) GARAGE 4.8 TH— 1 til/M M M \M NOTES: PANNONE ENG SVC, LLC FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 T15N, R2W, Sec 25, LOT 3' PAMELA HODGSON 16128 CARLISLE STREET PLAN EAGLE RIVER, AK 99577 o N� T 0 1. .� DESIGN PARAMETERS PRIMARY SEPTIC SYSTEM NO. BEDROOM. 3 (450 gpd) TANK SIZE. 1000g PERC RATE- 0.7 _MPI SOIL RATING: 1 GPD/SF AREA ROD. 450 SF SYS. TYPE. WIDE TRENCH 2 5 ED RF:' 0.64 MIN LENGTH: 57.6 LF USE. 58 LFx5'Wx2.5' E.D., 8.0' TD TOTAL AREA. 453 SF of A(gsl�) *: 49 M-7 Steve RC Par1n�F' PP,-. CE 8149 xe, Date 2/15/2016 Scale C=50' P.I.D. NO 051-281-03 'ERMIT N0. OSP161334 Sheet 1 OF 3 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND. MATERIALS USED IN CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55, 2. SCOPE OF WORK: INSTALL NEW SEPTIC TANK AND SOIL ABSORPTION SYSTEM. 3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 14 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 14 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. 4. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK. 5. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.0 W. ANC OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED. 6, THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES. 7. THE CONTRACTOR SHA -.LL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING . AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE ENGINEER. 8, THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN. 9, AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED—LINE AS—BUILT DRAWINGS TO THE ENGINEER. THE RED—LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND TANK ELEVATIONS. 10. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN—OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING. 1 1. THE CONTRACTOR PROVIDED DATA (UPON WHICH THIS RECORD DRAWING IS BASED) APPEARS TO REPRESENT THE PROJECT AS CONSTRUCTED. THIS DATA IN CONJUNCTION WITH THE PERIODIC FIELD OBSERVATIONS BY THE ENGINEER (OR HIS DESIGNEE) AS REOUIRED BY AMC 15.65 DOES NOT GUARANTEE THAT THERE ARE NO HIDDEN DEFECTS BY THE CONTRACTOR. 12. THE CONTRACTOR SHALL SIGN THE FOLLOWING: I CERTIFY THAT ALL WORK WAS PERFORMED IN ACCORDANCE WITH THE APPEND PERMIT, AND ANY AND ALL CHANGE ORDERS, AND THAT THE AS—BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED. CONTRACTOR: BY: TITLE. DATE: NOTES. �������\\ Date PANNONE ENG SVC, LLC ��OF:A�gsl11 z�ls�zol6 FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 i�P A(- Scale PHONE (907) 272-8218 FAX (907) 272-8211 *. 9 NTS /.... .. ... ....�P.I. D. NO 115N, R2W, Sec 25, LOT 31 051-281-03 PAMELA HODGSON �� Steven 'R"Pan'none / PERMIT NO. 16128 CARLISLE STREET �) cs. GE 8149 . ��! 0SP161334 DESIGN DETAILS EAGLE RIVER, AK 99577Dg0FES510NN Skeet 3 OF 3 SOILS LOG - PERCOLATION TEST TEST HOLE 1 SLOPE �S�F PLAN 3 OR ORGANICS 1 / n 2 GM/ SILTY GRAVEL / SM AND SAND 5 / 6 GRAVELLY SAND x SP/ WITH SILT I TH \ / SM -LACOBBLES W�� PRESENT 8 9 10 1 11 H-1 12 13 WAS GROUND WATER SLOPE 14 BOH ENCOUNTERED? N 15 IF YES, AT WHAT TH 16 DEPTH? -DRY x 17 DEPTH TO WATER AFTER MONITORING? -DRY 1 g DATE: 11110/16 9 DATE PERFORMED: 11/01/16 SOIL TEST RESULTS/ANALYSIS . PERCOLATION RATE <1 (min/inch) (Hydrologic Soils Group: HSG A) . PERC HOLE DIAMETER 6" . TEST RUN BETWEEN 4 FT AND 5 FT. . TEST RUN FOR OVER AN HOUR, LAST THREE READINGS PROVIDED. COMMENTS: Test hole excavated by ALASKA DIVERS.Test Hole was NOT required to be presoaked before Perc test due ,to sandy material (Table 3-8, Para.3, EPA Design Manual). PERFORMED BY: Dan Moran. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. /� NOTES: PANNONE ENG SVC, C, LLC J�QF .q � Dote FOR CONSTRUCTION P.O. BOX 102954 ANCHORAGE, AK 99510 . � . �gSl1) 12/15/2016 PHONE (907) 272-8218 FAX (907) 272-8211 j g� / - '�y ��� Scale NTS ...... .. ...... P.I.D. NO T15N, R2W, Sec 25, LOT 31 / 051-261-03 PAMELA HODGSON Steven :'Pan'none % PERMIT N0. 16128 CARLISLE STREET I�1j CE 8149 osP16133a SOILS LOG EAGLE RIVER, AK 99577 �������ao's' "y, sNz of 3 READING DATE CLOCK TIME NET TIME WATER LEVEL READING NET DROP 1 1111/16 12:00 --- 3.26 --- z 12:04 4MIN 9.26 6.00 (DRY) 3 1204 --- 3.26 --- a 12:08 4MIN 9.26 6.00 (DRY) s 12:08 --- 3.26 -- s 12:12 4MIN 9.26 6.00 (DRY) 040.002 Client: Pannone Engineering Services. Projects: 16128 Carlisle Tl5N R2W Sec 25 Lot 31 Date: December 15, 2016 Crowther Associates Particle Size Distribution Table Sample Source xx Sieve Size 3 inch 100 1-1/2 inch 100 inch 88 #4 56 #10 37 #40 14 #100 8 #200 7 0.02 mm -- Classification Gravely Sand with Silt (SP -SM) 1632 Bellevue Circle /Anchorage, Alaska 99515 Telephone (907) 349-21981E mail.' crou,iher t�i alaska.nei  MUNICIPALITY OF ANCHORAGE ) DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ' ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT PHONE ~]NEW LEGAL DESCRIPTION LOCATION NO. OF BEDROOMS Well Absorption area ~ Dwelling PERMIT NO. DISTANCE TO: '~ ~ ~ Manufacturer ~~ Materia~____~ No. of compartments Liq. ca acity in gallons Inside length Width Liquid depth , ~ Well Dwelling PERMIT NO. ~ ~ z DISTANCE TO: ~ ~ ~ Manufacturer I Material Liquid capacity in gallons ~ DISTANCE TO: Well 1/~ , Foundation?m , Nearest lot Ji,le ~, NO. of lines Length of,a~h line Tota' length o, ,'ne, Trench width Distance betwe~ Top of tile to Material beneath tile Total effective absorption area ~ inches ~ ~ ~.~ Length I Width Depth PERMIT NO. ~ ~ Type of crib Crib diameter Crib depth Total effective absorption area ~ Well Building foundation Nearest lot line ~ DISTANCE TO: ~ Class Depth Driller Distance to lot llne PERMIT NO. m Building foundation Sewer line Septic tank Absorption area(s) ~ DISTANCE TO: OTHER PIPE MATERIA~. ~. ~ ~ ~/~ SOl L TEST RATING INSTAELER REMARKS ~'~'~% ~O 1745-5 . c, ~ 72-01: -(Rev. 3/78) ~?ERMIT NO. ( ?804?8 ) ! ~PLICFINT MRS NELSON [ICFtTION OFF BIRCHWOOD LOOP fGBL LOT ~1 SEC 2.5 T15N R~W BOX ~i5 ARCH '_~9o0~.. LOT SIZE i0,.._ OO_..':/-~-IBR~'.~ FEET TYPE OF SOIL RBSORBTION _,'T_,TEM IS: TRENCH MR,~Ii"ILIM NUi'IBER OF BEDROOr'lS = 3< SOIL F.:ATING (S.q FT/E:R)=,=,.~,'"~' c, ,q I --,. THE REL:.!UIRED SIZE OF THE SOIL RBSORPTION ..,'r_TEM '-' C, EP'FH= 18 I_E~-~IGTH: 2E: I]RF~k~EL C, EPTFB= 5 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD. THE DEPTH OF R TRENCH OR PIT IS THE DISTBNCE BETWEEN THE SURFRCE OF THE GROUND RND THE BOTTOM OF THE E~CRVRTION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRRVEL DEPTH IS THE HINIMUM DEPTH OF GRRYEL BETWEEN THE OUTFRLL PIPE RND THE BOTTOM OF THE E~CRVRTION (IN PEET). ~:E~]LIIRED SEPT IL: TRF~K] SIZE= :'kElOE1 ,]F~L.L.C,t~S , ,= ,-' ', ' ' ' "' D.IR'[NG THE PERMIT RPPLICRNT HRS THE REz, PON..4BILITY TO INFORM THIS [,EFRRTI1Ei1T INSTRLI-RTION IN_,PECTION:, OF RNY WELLS RD.TRCENT T~'l THIS PRLFERTY 8ND THE NUMBER OF RESIDENCES THRT THE WELL. WILL SERVE. ' I 0[-4:. RRE RE[-!IJ I F:FZ[:. TFS,-] ( 2 .:. I F~SF'EC:T ' '--' BBCKFILLING OF RNY SYSTEM WITHOUT FINRL INSPECTION RND RF'F'ROVRL BY THIS DEPRRTMENT WILL BE SUB.SECT TO PF..O:.EL. UTION. MINIMUM DISTRNCE BETWEEN R WELL RND RNY ON-SITE SEWRGE DISPOSRL SYSTEM IS 100 FEET FOR B PRIVRTE WELL; OR 150 TO 200 FEET FROM 8 PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. OTHER REQUIREMENTS MRY RPPLY. SPECIFICRTIONS RND CONSTRUCTION DIRGRRMS 8RE BVRILRBLE TO INSURE PROPER INSTRLLRTION. PEF-:F1 I T E::<P I F~:ES DE£:E~48EF: _--<~L., - ,r~ -----¢, I CERTIFY THRT l: I BM FRHILIRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS RE; SET FORTH BY THE MUNICIPRLITY OF RNCHORRGE. 2: I WILL INSTRLL THE SYSTEM IN RCCORDRNCE WITH THE CODES. ~: I UNDERSTRND THRT THE ON-SITE SEWER SYSTEM WRY REQUIRE ENL. RRGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THRN ~ BEDROOMS. RPPLICRNT MRS NEL=ON ISSUED 8Y~I~-~--~-~--~'~-4'-~--~S.~-~- ...... DRTE.-~-- ............ ',/t 2 O~tEGEOT,.~,HNICAL ~' DEVELC ~MENT Box 90, Davis St., Eagle River; Alaska 99577 694-2774 or 688-2280 Russell Oyster 694-2774 Soils ~ Foundations Perfo~ed for: Name: SOIL LOG /~Z~5:~ ~-£ Tel. No. Mailing Address: Legal Description: Z~7-.~/, Depth (feet) 10 , 12 13 16 CO. Earl Ellis 688-2280 Land Development Ground Water Encountered: Yes Proposed Installation: Seepage Pit Comments: NO /i.I If yes, what depth~ Drain Field Date: