On -Site Water and Wastewater Program
4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP131263 PID Number: 051-312-34 • New ❑✓ Upgrade
Name:
Tilleen Anderson
ABSORPTION FIELD
❑ Deep Trench ❑✓ Shallow Trench ❑ Bed E Mound
❑ Other
Address
P.O. Box 771104 Eagle River, AK 99577
Phone
Number of Bedrooms
3
Soil Rating
•8GPD/SF
Total depth from original grade
2.5 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
0 Ft.
Gravel depth beneath pipe
2.5Ft.
Subdivision Block Lot
129B
Fill added above original grade
2-3 Ft.
Gravel length
80 Ft.
Township Range Section
15N 2W 25
Gravel width
5Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
From
Septic
Tank
Absorption
Field
Lift Station
Holding
Tank
Sewer
Line
Total absorption area
625 Ft2
Number of trenches
1
Dist. between trenches
Ft.
Well
N/A
N/A
N/A
N/A
N/A
TANK ❑ Septic ❑ S.T.E.P. 0 Holding 0 Other
Manufacturer
Anchorage Tank
Capacity
1,250Gal.
Surface Water
>100'
>100'
N/A
N/A
NA
Material
Steel
Number of compartments
Three
Lot Line
>5'
>10'
N/A
N/A
LIFT STATION
Foundation
>5'
>10'
N/A
N/A
Manufacturer
Anchorage Tank/Orenco
Capacity
250 Gal.
Curtain Drain
None
Noted
Remarks Existing Tank and Absorption Trench
Pump on level at
28 in.
Pump off level at
28 in.
High water alarm at
23in.
Decommissioned in Accordance With Municipal Code.
Pump make and model
Orenco
Electrical Inspections performed by
Installer
Royce Martin
PIPE MATERIAL House to tank D3034 Tank to D3034
drainfield
Drainfield HDPE CO/MT D3034
BENCH MARK (Assumed elevation) 100.0ft
Inspector A. Harald
Location and description
Garage Slab.
Inspection 1u 10/23/13 2"d 10/24/13
3" 10/25/13 a2'
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Conditional Approval: Date
uiC a 1
sr C.2C j•• - - '•,'�'®®
:* 49 Tr' •;7 t
4410 ,•,MICHAEL E. ANL. --.@SON :Let
1467-1.,.... GE - 4381 ,°'t a
4c .• 1aaA. c, —
e'_°;
!i®`6FE5S1�®®®®
awik
Approved � Dated/ r
Inspection Report_1-1-42.a6c
a
6
1n
r)
D
r
I I
a
O
KO-IMM0
I� I I I
am`0N-. o
j0
0 J
i' Iao
o 0 o
N c O
cd:
0
0
c
HUSKY STREET
0
0
o
m
o
Y -6Z l 401
9696Z 3„OC.OS.68 S
no
to,
rn F
H K
0
0
••►
N
t0
CO
/
S 00'16'151V 101.00'
O
ti
W
O
0
3
z
3
o-
0 0
0)
W • 0
10•3
0
� O
W
O
G
CO
0
m
O • 0
y0
71i
0
m �c
rt Z
Din
O • rn G
2 <
• 0
O °.
D 0
xm
vco xi.
D 0
01;m
10 Z 0
I —1
01
01
01
0
0
z
0
0
£ 10 Z °60d
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number: OSP131263
102.8
Finished Grade
x
1-
103.0
Page 3 of 3
PID No. 051-131-34
100.0
2 Insulation &
Geotextile Fabric
97 5
97.5
80' (Total Effective Trench Length)
PROFILE AS -BUILT
No Scale
86.0
Groundwater @ 93.2
10/15/13
•
x • 49th
i yyr y;
;MICHAEL E. ANDERSON j
.0 On,
.111:4.."' =• No. CE _�F.i
'
Oriiginal Ground
Drainfield Rock
97 5
97.5
80' (Total Effective Trench Length)
PROFILE AS -BUILT
No Scale
86.0
Groundwater @ 93.2
10/15/13
•
x • 49th
i yyr y;
;MICHAEL E. ANDERSON j
.0 On,
.111:4.."' =• No. CE _�F.i
'
WALKER ELECTRIC
CLINT WALKER
Phone 696-8964 Cell N 223-6304
Email ClintAlan a aoI eom
To: Martin Construction Company
PO Box 773326
Eagle River AK 99577
Date:10-28-13
Ref:15427 Husky St.
Permit: NA
10319 Colville SI.
EAGLE RIVER AK, 99577
Licensee 1310
This is to certify that on site sewer lift station at above mentioned property has been wired
in accordance with the standards of the National Electrical Code and manufactures
specification.
Systems were checked and performed as specified in the systems manual.
Clint Walker
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP131263
Tax Code Number: 05131234000
Work Type: Septic
Permit Effective Dates: August 19, 2013 to August 19, 2014
Design Engineer: ARC TERRA CONSULTING INC
Subdivision: T15N R2W SEC 25
Site Legal Address: T15N R2W SEC 25 LT 129B 6:0653
Owner/Address:
ANDERSON TILLEEN
PO BOX 771104 EAGLE RIVER AK 995771104
Site Mailing Address: 15427 HUSKY ST, Eagle River
Lot Size in Sq Ft: 30000
Total Bedrooms: 3
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions: Permanant barricades are to be installed to prevent parking over the proposed
field. The inspection report must show and describe the barricades.
Received By:
Date:
Issued By: � _ 1 Date: l/
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On -Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 051-312-34
TILLEEN ANDERSON
Property owner(s) Day phone
Mailing address PO BOX 771104 EAGLE RIVER, AK 99577
Site address 15427 HUSKY STREET, EAGLE RIVER, AK 99577
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section) T15N R2W SEC25 LOT 129-B
Lot Size 30000 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR:
(® all that apply)
Absorption Field
Septic Tank
Holding Tank
Privy
Private Well
Water Storage
APPLICATION IS AN:
Initial
Upgrade
Renewal
TYPE OF DWELLING:
Single Family (SF)
(w/wo ADU)
Duplex (D)
Multiple Dwellings
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
ybeortacia-
(Sign operty owner or authorized agent)
Permit/Rush Fees: 530
Date of Payment: $I Ja-II�J f
Receipt Number: 0a5DOFi
Permit No. 05113 /12145
Permit App_9-1-12.doc
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
ARC T ERRA
CONSULTING, INC
212 E. 51s` Ave, Anchorage, AK. 99503
Office (907) 868-3791, Fax (907) 868-3793
August 9, 2013
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject: Upgrade Sewer Permit — T15N R2W SEC25 LOT 129-B
It has been determined that the absorption field of the subject property is
saturated and encroaching groundwater. Subsequently, the owner has requested
we proceed forward to obtain a septic permit to upgrade the septic system. The
existing system will be decommissioned in place per code.
The general slope of this lot is from east to west at a grade of approximately 0-2%
over the septic area. On July 8, 2013 a testhole was performed to investigate soils
and groundwater. The results of this test are attached for your review. The
proposed upgrade will serve the existing 3 -bedroom house. We propose to install
a 5' -Wide pressurized trench. Groundwater was not encountered at excavation
but was at 12.5' at monitoring.
The property and adjacent lots are served by private water. There is no surface
water within 100' of the proposed system and there are no known curtain drains
within 50'. We do not expect there to be any adverse effect on adjacent lots by the
development of this system. If you have any questions, please contact me at 868-
3792 / FAX 868-3793.
Respectfully submitted,
ArcTerra Consulting, Inc.
Kenneth M. Duffus,
Attachments: On -Site Sewer Application
Wastewater Absorption System Details/Site Plan
Soils Log/ Percolation Test
20441 PTARMIGAN BLVD • EAGLE RIVER, AK 99577-8736 • PH (907) 868-3791 • FAX (907) 868-3793
WELL & WASTEWATER DISP❑SAL SYSTEM DETAILS/SITE PLAN
T15N R2W SEC 25 LOT 129—B
PST,
I
Y .1."
de' T6
O
c
C
FLAG PROPERTY LINES
WELL RADII & EASEMENTS
PRI❑R TO CONSTRUCTI❑N
m
N_
0
NO SLOPES >25%
W /IN 200' OF
PROPOSED SYSTEM
z
j NO PUBLIC WELLS WITHIN 200' OF
PROPOSED SYSTEM.
o_ NO PRIVATE WELLS WITHIN 200' OF
r PROPOSED SYSTEM EXCEPT AS NOTED
m NO SEPTIC SYSTEMS WITHIN 200' OF
I PROPOSED WELL EXCEPT AS NOTED.
:
Ti
Q
saltook
��3 OF ALS
N
• 1 /\
KE 11.
CE -7118
• (6/le3-. self
134'OFESBIOI3S'
\nhi.\"1110"...
n\Server\Storage\WE
DESIGN DETAILS
3 BDRM X 150 GPD = 450 GPD
450 GPD/ 0.8 GPD PER SQ. FT. (6 MIN/IN.)= 563 SQ. FT
(563 / 5'W x .64 RF (2.5' GRAVEL) = 73 FT. TRENCH
USE 1 TRENCH - 80' (L) X 5' (W) X 2.5' (ED)
Total depth of system is 6.5' from original grade.
Total depth of gravel below distribution pipe is 2.5' .
NOTES:
1. INSTALL 1250 GAL STEP & INSULATE TANK IF <4' COVER.
2. INSULATE TRENCH WITH 2' HD BURIAL FOAM IF < 3' OF FILL.
MIN. 2' FILL WITH INSULATION, >3' COVER NO INSUL REQ.
3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK.
4 CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT
WELLS, SEPTICS EASEMENTS, PROPERTY LINES, ETC...
Scale: 111= 100'
PAGE 1 OF 2
PREPARED FOR:
TILLEEN ANDERSON
PD BOX 771104
Eagle River, AK 99577
FIELD BOOKS
Bo RIDARY: BOUNDARY
COMPUTED:
DRAMN: BMW
STAXDKA STAKING
D" KMD •
8/8/2013
NW0653
13-173
AOT` JLS
DATE
DMT?. RIZ:
GRID:
ACM FMD FILE
JOB Na.:
TC ERR
oti
O
zrc
4s
pG \AC �l
free? NSULTING '0E.
• AK. 99577-
WASTEWATER DISP❑SAL SYSTEM DETAILS
T15N R2W SEC 25 LOT 129-3
LOT 12
S89°50'30"
DECOMM. SION
EXISTING S.T. &
INSTA NEW
1250 -IAL STEP
9
O
2c
FLAG PR❑PE"TY INES
WELLRADII & EASEMENTS
PRI❑R TO C'INST 'UCTI❑N LOT 129—A
S89°50'30"E
PRESSURIZED DISTRIBUTION SYSTEM HOLE SPACING DESIGN
1. RESIDUAL HEAD = 5'
2. HOLE SIZE = 3/16' = 1.00 GAL. PER HOLE @ 30 PSI
3. 30 GALS <PUMP DELIVERY)/1.00 GALS./HOLE = 30 HOLES
4. 80 LF LATERAL/30 HOLES = 2.6' SPACING PER HOLE
5. ALL HOLES SHALL HAVE CAPS INSTALLED PER MANUFACTURES SPECS.
a`a,
AlreS? 44-44
111 �� , /
CE -7116
4n
-'• ESS1011s
I. ' KENNETH 11 D
Scale: 1"= 30'
PAGE 2 OF 2
PREPARED FOR:
TILLEEN ANDERSON
PO BOX 771104
Eagle River, AK 99577
FIELD BOOKS
BOUNDA" BOUNDARY
STAIWk STAKING
ASSUIIM JLS
DOC. FILE:
ADHD F' FILE
COMPUTEk
DRAM: BMW
ctca®: KMD
DATE: 8/8/2013
ORIk NW0653
13-173
t.
Y
A
a
3
off'
es
vete e `*k-1
Rifz —.TING, el
Pq AK. 99577-575
WCTERR
cO
leo
e
o Q►RCTERRq
ARC TERRA
CONSULTING, INC
212 E. 51st Ave, Anchorage, AK. 99503
Office (907) 868-3791, Fax (907) 868-3793
SOILS PERCOLATION TEST
Performed for: Tilleen Anderson
Project:
Depth
(Feet)
Date Performed: 07/08/2013
T15N R2W SEC25 LOT 129B
TEST HOLE # TH 13-1
17-
18-
19-
ORG/OL
GM/SM
BOH
HOLE PRESOAKED
20- PRIOR TO TESTING
SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
Was Groundwater encountered? NO What depth? DRY
Depth to water after monitoring? 12.5' Date? 8/9/13
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
1
7/9/13
1:00
-
6"
-
2
1:30
30 min
15/16"
5 1/16"
3
*
1:31
-
6"
-
4
2:01
30 min
15/16"
5 1/16"
5
*
2:02
-
6"
-
6
2:32
30 min
1"
5"
7
8
9
10
11
12
Water
Added
Percolation Rate 6 (min/in) Pere Hole Diameter
Test Run Between 4 feet and 5 feet
I, Kenneth M. Duffus, certify that this test was performed in accordance with all State
and Municipal guidelines in effect on this date.
1 MUNICIPALITY OF ANCHORAGE
•
\�
r
\C //
'
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME
TOO 1\
PHONE
❑ NEW
XUPGRADE
MAILING ADDRESS
P O RN( 111 a oge. l ues
LEGAL DESCRIPTION
L. lz9a 5Z5 7-I5IN-I eat-u Sill
LOCATION
14-h/BDCrrE-C.
fp
NO. OF BEDROOMS
3
SEPTIC
TANK
DISTANCE TO:
Well
Absorption area
/
Dwelling
PERMIT NO.
Manufacturer
EA,
I 5 /I / s
v G
Material
No. of compartments
Lig. capacity in gallons
IF HOMEMADE:
Inside length
Width
Liquid depth
O s-'
JTZ
= Z F
DISTANCE TO:
Well
welling
PERMIT NO.
Manufacturer
/
Material
Liquid capacity in gallons
TILE
TRENCH
DISTANCE TO:
Well /
��Q •�
Foundation /1
�I_ 1
Nearest lot lin
/b i��
PERMIT / ?
19Uz
No. of lines /
Length of eai ,l
il`!'
e/ ±
Total length pfvly/�eq .
7I T
Trench width
3V inches
Distance between Aire
/t
Top of ti le to finish grade 7 /Material
6— '-7 }
beneath tile
48 inches
Total effective absorpti Area
-L7Z, Weic
SEEPAGE
PIT
Length
Width
Depth
PERMIT NO.
Type of crib -
Crib diameter
Crib depthA /
Total effective absorption
area
DISTANCE TO:
Well -
,•
Building foun tTdn
Nearest lot line
_i
Class
Depth
Driller
Distance to lot line
PERMIT NO.
DISTANCE TO:
Building foun a i6nx '/
gvy4r II¢ 1/ j
Septic tank
Absorption area(s)
OTHER
PIPE MATERIALS
/1
LJI/
IV
SOIL TEST RATING J9 �j�/�
n
INSTALLER
ROS`f" I fioi""e s
REMARKS
-1—
C: 4 tr
1.
10*
- comm
t, . A. S.
ik;tia No. 1457-E .
,•:%'r•4
$®tA�CfESSt "N\-,,Q' i
tai 13
-
61k'
`Ly.4>0aa. -
J
.4111
//
AP-'p
.e DATE LEGAL/ EMI(Mf-'[7IM'�..
fee r--7--GA °RS &!;®It
tqk QS?
72-01.3 (Rev. 3/78)
//
N...311-4 Ia' tl :Z s fi- m PA e_: -I-I_ FZ IF;I C E
DEPARTMENT HEAL_ T H FW) E:Wl I RONt'` ENTAL_ R ITECT 1 ON
825 /I .' STREET.. ANCHORAGE: AK. 995I 1'i
264-4720
P:.:N —7.,"s; .S_ -I- VT. ' _ E. _ fl „_N E F: 9__n. s= =" k Fm,; Fir) E: = FT, E-:" F- .' t' T I _r
FERMI T Ni i. 20632
APPLICANT TODD
L_ 't AT I ON
LEGAL L129B 525 T:LSN R2h! SM
SAN BOFLEL DRIVE
TYPE OF SOIL ABSORPTION SYSTEM IC: TRENCH
MAXIMUM Y.,IIi'9EFT; OF E:ECF:OCII''i:iS; _
LOT SIZE
70000 _QUIFF FEET
_OIL RATING ':'Fr! FT/BR).:: 194
THE REQUIRED -'-- --
.H_ : .E. �.F- OF THE _OIL AI=-'•:-�!iF: F''!�I!_ila ��`r==TE t' IS:
DEPTH
OF..A TRENCH ORTHF
ISLTHETI:EISTA CEtaBE?.WEEN THE FI OR C'F.r'ITFFT Ef;.
THE LEN 1 MEN ION LENGTH N1 I H I Nt FEET) OF THE TRENCH
THE C!- - !SURFACE i !r L'F-il.
Fi.?I-II_NF' AND THE BOTTOM TOM !p THE 'y'F t FEET).
THERE IS NO .E„1 WIDTH FOR TRENCHES.
THE GRAVEL DEPTH IS THE MIP'L:EP'U_M DEATH E!F GRAVEL BETWEEN THE OI.IFFAL-L.. P11
AND THE BOTTOM OF THE EXCAVATION (IN FEET)
Fr:E_:a_!u:P: ^EL,n ”} VE:. F -li. i c c _ 7_fi:s!;_2n:'e Caw- P- P._..c_ur-°C=
PERMIT EPF'LICANT HAS THE RESPONSIBILITY TO INFIRM THIS DEPARTMENT DURING THE:
INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY HI1ti THE
NUMBER OF RESICErJ ES THAT THE WELL HI'LL.. SERVE.
'_'h i 1 e::_ =- .:} k. rJ P-'=" E I'c ::: ry 1 °._E 5NA "- :: FIR F: E-._: FRAEGUJLEFRIECE
EHCK IL_L_.INO OF ANY '-Y_TEYL WITHOUT F:E1'AL... INSPECTION TION APUD APPROS,'AL. BY THIS
C'EF'ARTi'IEN`I" WILL. BF SLiBJECT TO PROSECUTION.
MINIMUM DISTANCE BETWEEN A M_L_L_ f=!hdF? F!P'd`r' ON-_ITE=,L=d•.IAOF. DISPOSAL SYSTEM IS
100 FEET FOR A PRIVATE MEL.i._ OF: 150 TO ;;_CIH FEET FROM A PUBLIC IJE:t-_L. DEPENDING
UPON THE T'YF'E OF PLIE!L_IC WELL..
Y'E1Nir'llil''1
DISTANCE: FROM A PRI'V'ATE WELL_ TO A PRIVATE SEWER LINE. IS 25 FEET AND
TO A COMMUNITY SEVER LINE IS 75 FEET.
OTHER ?:LOi_ITREEMENT.E MAY APPLY. SPECIFICATIONS AND r:OY,sTRU7:.-E'.IEir'L DIAGRAMS ARE
Fit,AILFIBL..E TCI INSURE F'ROF'ER INSTALL.ATIC!P+!.
E F. -;.:M 17" ........:F' T F_'.!E:EE E RUN'_ Ic:.,,-PE3F-'.F;:
I C IFY THAT
L' i AM bFIM1LIAF: WITH THE REQUIREMENTS FU4: EIN--'`;ITf ':rH F_ AND WELL_ AS _ET
FORTH E_'',' THE MUNICIPALITY OF AN HLIFF,hf
• .. I WILL INSTALL. THE '-"--' 1
._. _. _.,'�.!L_Y', IN A!_Ci1F.:C:,FIP,U:_F; WITH THE CODES.
3:UNDERSTAND
_'L' 7. i �PfTHAT THE ON-SITE SEWER SYSTEM MAYREQUIRE ENLARGEMENT
-E_IEENCE
IS REMODELED TO INCLUDE MORE THAN 3 BEDROOMS.
AF'PL_IDINT TOM
C'4P'-YY
FIEF7724a
V4. 3
PERFORMED FOR:
LEGAL DESCRIPTION:
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L. Street, Anchorage, Alaska 99501 264-4720
SOILS LOG — PERCOLATION TEST
Z
❑ SOILS LOG
PERCOLATION
TEST
DATE PERFORMED: 4 J rJ Z
Cc 2s-' y,o
10
11
12
14 / / CL,Lyvy; v
15 � i 3_ ..
too ( S
e,coIc-ot I ecf j
511 -Ty S D7 rived
((rn)
16
17
18 nee co ••
RaMrt A. �,• f'
'°o° Ho. 1957 t+`?
19 ��Fp
4.° r arm
h#04OFES �P
20 r,.p-'te .
COMMENTS
SLOPE
[r
WAS GROUND WATER
ENCOUNTERED?
IF VES, AT WHAT
DEPTH?
O
/ P
/ 3 E
L
F
L
7
Reading
Date
GTrimoss
e
Ne
Time
Depth to
Water
Net
Drop
ptt
/XIGj Z.A
7125 �'
5 /'
3 $
Z.
it
-7:55I°
3prn/N.
q4 ti
3 a
o 1 rr...s
Cr
ti
S:isP
5
6
5'zcP
iom,N,
lig
P ,
PERCOLATION RATE
TEST RUN BETWEEN
FT AND
(minutes/inch)
/ FT
r
PERFORMED BY p h. SW1��{
r jilV7wi�i ' A1.flF..rC�a
PRIM -297Q
72-008 (6/79)
CERTIFIED
DATE:
/• - MUNICIPALITY OF ANCHORAGE
®
\\1825
,V-1--K__-,>42
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTALENGINEERING DIVISION
L Street -Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME/ /94P OONE -,
04-Rat 4 1 6 � 6 �J 2 .S
pNEW
❑ UPGRADE
MAILING ADDRESS 44/7AI e
LEGAL DESCRIPTIO
/296 S 5—; 7- �� ,E�2 cam/
LOCATION J /°7 / /% )/
NO. OFBEDROOMS-
D Y
I- Z
0
DISTANCE TO:
Well/ .&
/(%Q
Absorption area
Dwelling f -f-
`
lS
PERMIT NO. k 11. 1 1
'/��rf%j/(/%jl��,�'y'
—
OP
-
ManufacturerM
o-
ee %
rid
r «/
No. of compartments c--)wH
l '
Liq- a acity in gallons
/&)0
IF HOMEMADE:
Inside length
Width
Liquid depth
D Y
..i _,02
2MF
DISTANCE TO:
Well
/
Dwelling
PERMIT NO.
Manufacturer
/ (
Material
Liquid capacity in gallons
TILE
DRAINFIELD
TRENCH
DISTANCE T(
Well
F.undation -
Neare lot li -
- 4
'ER IT NO.
No. of lines U
Lengt, r each lige2�'
��
'-�o : €ti i of I" •
T--pfh. • ' .;D-'-ce
inc ies
between lines
Top of tile to finish grade
Material beneath ti le
inches
Total effective absorption area
SEEPAGE
PIT
Length
Width
Depth
PERMIT NO.
Type of crib
Crib diamye% /1'
Crib depth
Total effective absorption
area
DISTANCE TO:
Well l/
Building foundation
Nearest lot line
w
Class Cz
z, X i `
(Dgptb_
elm✓�
Driller
Distance to lot line
PERMIT NO.
DISTANCE TO:
Building foundation-: -.,, ,
• --3:•Y.
$ewer"line
Septic tank
Absorption area(s)
°
F
OTHER as
i
�•
/
PIPE MATERIALS////�J,(
r
/
C 1 .4'.11i%T A
n "
y
�l
�',
SOIL TEST RATING
INSTALLER
I
t tr.'!"
I
REMARKS
-F55167/ ow ',qMt
•...•.u.i
//
9111
1
II
1111
rat
s'Jt lJ'
c4
^E111116
0 .Oioie i 7, 'd dere eR
72/
in
r
DATE LEGAL
APPpOVE/y/"/��// f///mayam/ / /
-ryf3 (Rev. 3178)
MUNICIPALITY OF ANCHORAGE/-'
Department' t' Health and Environmenta' ?rotection
825 L Street, Anchorage, AK. 99501
264-4720
* * * HANDWRITTEN PERMIT * *
WELL AND/OR ON-SITE SEWER PERMIT
DE go,C /ODD Mailing Address: p sX
Applicant:
Location:
Et'.,
Legal Description:
Phone Number: (pA e '.ZS o3
% ism ,.2't) .S 23- 27`, /) Size:
Type of Soil Absorption System Is:
Trench: Drainfield: Seepage Bed:
Holding Tank: X
Maximum Number of Bedrooms: Soil Rating(sq.ft/br)
The Required Size of the Soil Absorption System Is:'
DEPTH LENGTH GRAVEL DEPTH WIDTH
The length
depth of a
the bottom
The gravel
the bottom
dimension is the length(in feet) of the trench or drainfield. The
trench or pit is the distance between the surface of the ground and
of the excavation(in feet). There is no set width for trenches.
depth is the minimum depth of gravel between the outfall pipe and
of the excavation(in feet).
* * REQUIRED SEPTIC(HOLDING) TANK SIZE = 1000 GALLONS *
Permit applicant has the responsibility to inform this department during the
installation inspections of any wells adjacent to this property and the number
the well will serve.
* * * TWO(2) INSPECTIONS ARE REQUIRED # * #
system without final inspection and approval by this department
prosecution.
of residences that
Backfilling of any
will be subject to
Minimum distance between a well and any on-site sewage disposal system is 100 feet
for a private well or 150 to 200 feet from a public well depending upon the type
of public well. Minimum distance from a private well to a private sewer line
is 25 feet and to a community sewer line is 75 feet. Well logs are required
and must be returned to this department within 30 days of the well completion.
Other requirements may apply. Specifications and construction diagrams are
available to insure proper installation.
* * * PERMIT EXPIRES DECEMBER 31, 1 9 8 1
I certify that:
(1) I am familiar with the requirements for on-site sewers and wells as
set forth by the Municipality of Anchorage.
(2) I will install the system in accordance with codes.
(3) I understand that the on-site sewer system may require enlargement if
thc,residence is remodeled to include more that 3 bedrooms
Signed:
i /2? ,inhz
Applicant
Issued by:
Date: 6— Ala (.4
Temporary holding tank until field is installed Spring 1982.
SWP/024(1/81) Existing sewer serving a trailer now that will be abandoned.
A bed system including a lift station will be required for
new residence.
te
Ate, { ,€€ .
,9)
%l"� •fes/��f
cc
(-1r.i %4tit" )
f.G= -
/L't2.Q6
=iiasC�Y //.�tr>i
fir_
/z
%2.
j
/y /7
-
a -
/ a
/8
%:
' ®_.
6 °
J
0p ,.o
� }}--
Y`
?ta3''
w
:�
S`
/2.
r� -/ C20 afar I.
u fy.: �,.a ‘A -r- yTt e
. 10- c?--2aaree42
�% c'Ltr('-r-2tC30.fIG'Yl.�/
.CL - 4
3- _3 i- 14 4,4,
j_ i7, /�/ "�,
iva4<1r/;, �,.•, .s�>
Ir
le LGt f` i',' +t j ay'
`Iu` _e '5 ela;Je i • .¢r
/✓ ..
2
` t<
r u
>../ ,
;3
3S
> _3
,c
(°
0 '
a
3r
,>
A-
C{.�
�,.
._
/4
• c.../L
...
ty
/..F
_..
el . ,r {
4 9•
_
-
-
(/
1
1
(. i9
��utn
t
t
/
,9)
%l"� •fes/��f
cc
(-1r.i %4tit" )
f.G= -
/L't2.Q6
=iiasC�Y //.�tr>i
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Qualii4R"'a\TER ANCHORAGE AREA BORO•
I!�(i
3500 Tudor Road—Pouch 6-650
Anchorage, Alaska 9950
N° 877
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME /eO r , 7-v__,
Cdf'/fin/ M 6/'-'-
MAILING/t• ����
ADDRESS �Q� /� vv/fc. 7)1,-P HONE
LOCATION LEGAL DESCRIPTION boy'/ -1/4 /4.12, _r4r/r
SEPTIC TANK:
DISTANCE FROM WELL
.2s2 T/Lcg
� vC�
NUMBER OF
MATERIAL ,
COMPARTMENTS
GALLONS. INSIDE LENGTH �
LIQUID CAPACITY<��� `5Z-��O
INSIDE LIQUID
WIDTH DEPTH
SEEPAGE SYSTEM: SEEPAGE PIT:
r / ! /
NUMBER OF PITS //�� Q OU�TSSIDDEEp`1IAMETER OR WIDTHID/7 LENGTH /1 DEPTH '"�
LINING MATERIAL OLFO ( ^ ) - DISTANCE FROM WELL /00 fie- BUILLDDIING FOUNDATIOI�"'e
NEAREST LOT LINE 7 ® w 5 TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) / SQ FT
TILE DRAIN FIELD:
TOTAL LEN TH
DISTANCE FROM W FOUNDATION NEAREST LOT LINE OF LINES
NUMBER
ABSO
LINES
TION AREA
DEPTH: TOP OF TILE TO FINISH GRADE
DISTANCE BETWEEN LINES - TRENCH WIDTH
SQ FT LENGTH OF EACH LINE
DEPTH OF FILTER MATERIAL BENEATH TILE IN ABOVE TILE
TOTAL EFFECTIVE
WELL:,, II DISTANCE FROM
TYPEIA3a DEPTH , BUILDING FOUNDATION
LOT LINE
WATER
SAMPLE
NEAREST
NEAREST SEPTIC SEEPAGE OTHER
SEWER LINE TANK SYSTEM CESSPOOL SOURCES_
DISTANCES:
Oftr' Bee
/nQ
nLS 4
61�v
1'1A le
DIAGRAM OF SYSTEM
it)
DATE
�/6 APPROVED 1>"� : C-"`�'""��
/ HEA AUTHORITY
( ATER ANCHORAGE AREA BOROU'
DEPARTMENT OF ENVIRONMENTAL QUALITY
3500 TUDOR ROAD
ANCHORAGE, ALASKA 99502
CASE #
Performed For Robert '7 -odd Date Performed C, — a4- 7 2.
Legal Description: Lot/zc/aBlock Subdivision b SE1 Ter. 25- 775N 172W S.n,
This Form Reports Soils Log Percolation Test
Denth
Feet
Soil Characteristics
1
2
3
n
5
6
7
8
9
10
4
0
rapso:( (a't)
(s, 'r)
i4 C-raveI (2-(A
C o rSC
s, X 4-7
saV.c1 ((of-6%rj)
crave/ (6 yj-1t4)
iZ 4 s Ground Qater Encountered?
If Yes, At what Depth?
G1I
G M
Yes
CSec
1
,r,
rake) 04
Reading
Date
Gross Time
Net Time
Depth to H2O
Net Drop
Percolation Rate Minute
Proposed Installation: Seepage Pit Drain Field
Depth of Inlet Depth To Bottom Of Pit Or Trench
COMMENTS;Ff.// / In 1
(rM (�2zv) S®r r�edronv.�. ry[i Je*' I< }prn ba hi y Wa'f'er, wn'1er (f
crow, cog r< Swed 14y�r
-.I5 ti,+l-c., - o n;1. 1111s CO:,kf,,;„
u occur 4 yy*Anc it retina
Lr ata Certified By:
Test Performed By
4- A
Date:
Parcel I.D. 051-312-34
Municipality of Anchorage
On -Site Water and Wastewater Program
(907) 343-7904
Certificate of On -Site Systems Approval
1. GENERAL INFORMATION
Expiration Date: r 6 -
Complete legal description T15N, R2W, Section 25, Lot 129B
Location (site address) 15427 Husky Street Eagle River, AK 99577
Current Property owner(s) Tlileen Anderson Day phone
P.O. Box 771104 Eagle River, AK 99577
Mailing address
Real Estate Agent Day phone
2. TYPE OF DWELLING:
O Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
Three
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well 0 Individual 0
Individual Water Storage 0 Holding Tank ❑
Community Class Well ❑ Community ❑
Public Water System 0 Public Sewer 0
WaiverNariance request for: Distance:
Received by:
COSA to be relea
ed to j$e engineer, unless otherwise requested by the engineer.
Date: 11`(66 J�
COSA Fee $ 0)5' W1 MAO- Waiver Fee $
Date of Payment ioLaii 4 1V'3 C Date of Payment
Receipt Number 004055 Receipt Number
COSA # Cr- - 1315(8 Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name -Michael E. Anderson, P.E.
6. DSD SIGNATURE
System #1 Approved for 3 bedrooms
System .#2 Approved for bedrooms
Disapproved
Conditional approval for
By:
Phone 522-7773
Date 10/27/2013
`vea^sOe.
to ct nciatlemakttint,014FF '
49 See ,6 CE -436'1 pet,
% +dc —fele
, ®�,b Obbbs
bedrooms, with the following stipulate•
OF ANCA iii
O,
=
ON-G�
J
SI
it- AND
=a WASTFWATER 661_
PROGRAM
J
i�c
&C0 Original Certificate Date:
The 191unicip 7•f,arrcnorage Development Services Division (DSD) issues Certificates of On -Site
upon the presentations given in paragraph 5 by an independent professional civil engineer registered
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist
Septic System Advisory
Well Flow Advisory
COSA blue sheet_f
X
NT
raj SERV
)mm)111»
Systems Approval (COSA) based only
in the State of Alaska. The Municipality
Nitrate Advisory
Arsenic Advisory
Other
If more than 1 septic system is on the lot:
COSA Checklist # of
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description: T15N, R2W, Section 25, Lot 129B
A. WELL DATA
Well type Private If A, B, or C provide PWSID #
Date completed 6/25/74 Sanitary seal (YIN)
Total depth 76 ft. Cased to 50 ft.
Date of test
Static water level ft.
Well production 5 g.p.m.
FROM WELL LOG
6/25/74
14
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mL Nitrate 2.87 mg/L
Arsenic N/D ug/L Date of sample: 10/11/13
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material STEP/Steel
Tank size 1,250 gal. Number of Compartments
3
Foundation cleanout (Y/N) Depression over tank (Y/N) N
Date of pumping New Const. Pumper
Parcel ID: 051-312-34
Well Log (Y/N) Y
Wires properly protected (Y/N) Y
Casing height (above ground) >18 in.
AT INSPECTION
8/30/13
29
ft
.5*.
g.p.m.
Collected by: Anderson Engrg.
Date installed 10/23/13
Cleanouts (Y/N)
High water alarm (Y/N)
C. ABSORPTION FIELD DATA
Date installed 10/24/13 Soil rating (g.p.d./ft2 or ft2/bdrm) .8 GPD/SF
Length 80 ft. Width 5 ft.
Total depth 4.5-5 ft. Eff. absorption area 625 ft2
Date of adequacy test New Const.
Fluid depth in absorption field before test
System type 5' Wide Trench
Gravel below pipe 2.5 ft.
Monitoring tube Y Depression over field N
Results (Pass/Fail) For _ bedrooms
in. Water added gal. New depth in.
Elapsed Time: min. Final fluid depth in. Absorption rate >=
Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date
g.p.d.
D. LIFT STATION
Date installed 10/24/13
"Pump on" level at 28 in.
Size in gallons 250
"Pump off" level at 28 in.
Datum Top of Vault Rim Cycles tested New Const.
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot >100'
Absorption field on lot >1001
Public sewer main N/A
Sewer /septic service line >25'
Animal containment areas >50'
Y
Manhole/Access (YIN)
High water alarm level at 23 in.
Meets alarm & circuit requirements?
On adjacent lots 100'
On adjacent lots >100'
Public sewer manhole/cleanout
Holding tank N/A
N/A
Manure/animal excrete storage areas >100'
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5 Property line >5,
Water main >10' Water service line >10'
Wells on adjacent lots >100'
ABSORPTION FIELD ON LOT TO:
Property line >10' Building foundation >10'
Water Service line >10 Surface water >100'
Curtain drain None Noted Wells on adjacent lots >100'
Absorption field >5
Surface water >100'
Water main N/A
Driveway, parking/vehicle storage >10'
F. COMMENTS
Well Flow Test Completed by ArcTerra Consulting, Inc.
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Michael E. Anderson, P.E.
Engineer's Printed Name
Date 10/27/2013
COSA brown sheet 10-10-12.doc
���°e
4,* SytB
el
•
•e r„ oMICHAEU E. ANDERSON ;Luceo
0 "J e� CE - 4381 '
es fF9FD°',®
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Elmore Street
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
Water Well Advisory
Certificate of On -Site Systems Approval (COSA) # 131568
During a recent COSA on-site inspection and test of the potable water
supply well on Block , Lot 129B of T15N R2W Section 25
subdivision, the well's productivity was determined to be 0.45 gallons per
minute. The minimum well productivity required by this Department (AMC
15.55) for a 3 -bedroom residence is 0.31 gallons per minute. Although the
subject well currently exceeds this minimum requirement, all parties
concerned are advised that the production capacity of the well may fluctuate.
Restriction of non-critical water uses such as washing cars and watering
lawns and gardens may be required.
This advisory must be attached to all copies of the subject Certificate of On-
Site Systems Approval.
0£1 101
-;old uolslnlpgns peploo0J ay{ uo Joaddo 40U op yolgm suoµop;seJ JO 's4uoueAoo
`s4uawOSDO AuD ;o eoue{slxe ay{ euluue{ep o{ JOUMO 044 ;o A401gjsuodso. 044 sl 41
o soy 'BBDJOgOuy 40 , cla2, ' v Qoi->�
;o ADO y,}S2 044 0144 P01o0
•uos r4 pe;oolpul SD 4deaxe Ajaedoid plus UO S;UBWOSDB
elglslA 40440 JO SOU!! UOJSSfwsuDJ4 'SAOMpDOJ OU 010 01044 ;044 pUD soslwoJd
peAenans ay{ uo y000Joue o40Ja44 ;ueoDfpo 6u141 Apedold e4{ uo s;uowenoJdwl ou
pogo '0011044 {ueoofpD A;4Bdoid 044 o4Uo y000nue 4ou op puo scull Apedo.d ay; u14l1M
CID manna p040n1s s4uowoAoJdwl 044 4044 puo 8ulpiooea e8oloyouy
(L£ l—ZL 'oN 401d) 6Z1 101 13V81 11V/14S 1118 .30 '08fS 3H1 01 ON108033V '86Z1 101
:A4Jedold pogposep BulMollo; 094 poAaAJns BAD4 1 4044 A;NJBo Age.aq 1
woo•AeMnsOuol®uo44ouof / woo•Aenans6uoIouen
x03 sz94—zzs (Lo6) sJohenans purl pace/sj6es
640£-51566 oIsoly '06DJoyoeu4
y '9denueny I9L49—ZZSAJDO 009l(L061)I Ouil S2+DIOOSSy )' 6u D1
00Z—£1. 'op 4oefo4d
V-611 401
,40'662 M„0£,05.69 N
»N3 .9'4 x ,YZ
£S9 MN
0160 ,o£ = nl 31V3s
NOIIVAN3S3d OV02J MEI ,0Z
NVId 101c1
,00'0£
ni
Odd 'ONOO
ANtN3 0383A00
GYd '3N00
,9'91.1
113M
'J'0 toz'o£
8-6Z l }01
N
,96'862 3„0£,09.69 S
3-611 1017
31011
OLLd3S
0
LLd3sNV310
3dId NMONO
,4'SS
z
0
V
41
0
rri
0
c
cn
m
10/18/2007 06:17
05l'03;207'3 92: 46
180000000000
vboefraW. ti
, RCTERRA
Corse '1sT1mG. INC
212 E. 51* Ave, Anchorage, AK. 99503
Office [907) 868.3791. fax (9071 868-3793
August 30, 2013
Ti.fleet Anderson.
15427Husky St.
Eagle Rivett, AK 99377
RE: T15N R2W SEC 25 tor 129E - ON-SITE WATER PRODUCTION
Per your request, we have inspected the on-site water system of the above referenced
3 -bedroom property. This investigation was based on observations of the day in which
the well flow test was performed and according to Municipality of Anchorage (MOA)
record documents.
Prior to commencing the well flow test. the static water level was measured at 29' from
the top of cuing. The wellhead consists of 6" steel casing extending 2' above grade
with a sanitary seal and conduit. 'The well produced 9.45 gallons per minute for gp 3),
which meets minimum MOA water production requirements of 0.31 gpm
bedroom single-family 'evidence Per MOAA documents,
previous
testing hage tank as hown the
lesser water production (.
garage augments the water system.
The assessment of the condition of the well applies only to the conditions as of the day
tented. The flow rates may change due to subsurface conditions that may not be
observed from the sarence, changes in land al soil
levels that may Mutilatet'
ate during the year and the water usage of groundwater
the fmily being srved
by the system.
If you have any questions, please feel free to contact me at (907) 868.3791 I Fax (9971
368.3793.
Respectfully
Arc Terra Consulting,Inc,
Kenneth M. Duffu
PAGE 01
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anctiorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. or/ :5/ .i3,/
1. GENERAL INFORMATION
'Complete legal description 1 ,(J .??,414/ X,
Location (site address or directions) /rya /47/cfine y �T
Current Property owner(s) .A7394 re ,0,,g-, e9.RAN Zzp Day phone 5 - ©�
Mailing address /e. >3,9x
Lending agency Day phone
HAA # D 1 O s-1
Expiration Date: 9 - / 6--- 0 14 -
Mailing address
Real Estate Agent Day phone
Mailing Address
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 3
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank
Community On-site
Public Sewer
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only "upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with
new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.)
Certificates are valid for one year for properties served by Class A or B wells or a public water system. The
Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-
site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation.
Name of Firm ,��Lf d�.� %��-z S • • Phone
Address /G9/ 1./x-• 51- ?7
Engineer's Printed Name 4y,/,'5 h/ e'/ Date
5. DSD SIGNATURE
I/ Approved for 3 bedrooms.
Disapproved.
Conditional approval for -- bedrooms, with the following stipulations:
. CHRISTOPHER R. WOOD
Additional Comments
`kkl,-IY�OF(rtr
';
�; ON-SITE • •c=
WATER AND ; r"
WASTEWATER :
PROGRAM ;
•
JJ�I``/J'" S i"
Attachments:
HAA Checklist X Maintenance Agreements
Septic System Advisory Supplemental Engineer's Report
Well Flow Advisory Other
(Rev. 01/02)
Original Certificate Date: — LC" 0 It
Legal Des iption:
A. WELL DATA'
• Well typeP RMT
Date completed G/ZS/jy
Municipality of Anchorage
Development Services Department
Building Safety Division
`On -Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.clanchorage.ak.us
(907) 343-7904
HEALTH AUTHORITY APPROVAL CHECKLIST
/5",k) 12 r In) SEe 2.5" Li 129 .l3 Parc el ID: 057 - 3/2.= 3'/
Total depth 74 ft.
If A, B, or C provide PWSID #
Sanitary sea (Y/N) ,
i
Cased to LO ft.
FROM WELL LOG
Date of test
III
Static water evel
Well production
ISI
(., /7y
ft.
g.p.m.
Well Log 9N) Y
rll't"
Wires properly protected®/N)
i!'1 i
Casing height (above ground) 2 ii
r1,
AT INSPECTION 1
II :PIT
(Qt1;
,i� ft.
; a/q
/ 3D(1i�94m-/
- l,vaci
6,411q srvQ " 84•4 -DDS
r.tisr 4 L t 11
,14
Other bacteria p (#9 colonies/100 ml.
YI
WATER SAMPLE RESULTS:
1'
Coliform i i. 1/ colonies/100 ml. Nitrate a 93i mg./1
Arsenic. i % mg./I. Date of sample: 3VO.
B. SEPTIC/HOLDING TANK DATA f,
Tank Type I/Material
y�aiy Collected by: .440'1. -_ 4,0e4C rOla-y
11
Date installed
II
Tank size /D gal. Number of Compartments Cleanouts 'N) yt.5
Foundation'cleanout�l) ° Yffs Depression over tank ( 'tie High water alar 4.4.— O/
Date of pumping . .v, ,,,/D° HI
III II i ir- Pumper J �o w,e ip�in/e.,--.
C. ABSORPTION FIELD DATA k } ill
d 11 ! 'i . 2 2 ' it
I
rating (g p d./ftor ft /bdrm) /9 ' System type /Air—vie,/
Date installed- /98' Soil
j
Length I I •i$ ft. Width '1 o? 0 Grave below pipe y i ft.
Total depth i ft. Eff. absorption area }�ys72-ft2 Monitoring tube i/ ! Depression over field iC29
Date of adequacy test a/2.2/d �i .Results(/Fail) • f�..,,,, ' 1 For`_ 3 bedrooms
Fluid depth in absorption field before test D in. Water added /s 46gal ? New depth Sit in.
Elapse Time: min. : Final fluid depth l : .• A , J A r'S 1 il 3yin. Absorption rate >_ '7V •g.p.d.
Any rejuvenation treatment (past 12 mo.), (Y4 type) �� f yes, give date 41,4-
7//o /7Z
D. LIFT STATION
Date installed _ Size in gall "' Manhole/Access (Y/N)
"Pump on" level at in. "Pum • = evel at in. High water alarm level at in.
Datum Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot /4/9 / On adjacent lots _ /41-1
Absorption field on lot / 3-2 1 On adjacent lots //D
1 7,3
Public sewer main
Public sewer manhole/cleanout 7" /r''D
Sewer /septic service line '' 6' Holding tank f /d Di
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 56 1 Property line yZI 1 Absorption field 45 '
Water main 1 to' Water service line / /e, ' Surface water r` /UO '
Wells on adjacent Tots / /e '
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line / 7 Building foundation 6 c' Water main / /D
Water Service line 71 /Q ' Surface water f /de' Driveway, parking/vehicle storage d tJ2 ldst)
• Curtain drain .7' �p Wells on adjacent Tots 1 /DO "
F. COMMENTS. cro Q*bee. +. iorn Wi5 Ape'' F 4PtV ,1 '.
ms . F, ivF�.e.4 D .414 Y /3,e "// ,5/7'r1:1, zG Asa
G. ENGINEER'S CERTIFICATION /joetiisGi- 1�� /301" -4/ ,3t0/4`
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA HAA guidelines'in effect on this date.
Engineer's Printed Name Gt ZSi c t I2.C.o\
Date " G io4/604
HAA Fee $ 430 0 o Waive r Fee $
Date of Payment 61710*
Receipt Number OH 7 2.
(Rev. 12/01)
Date of Payment
Receipt Number
�rz6' "so 'Jo `Gr/ z9ep., 96'
AS BUILT
I HEREBY CERTIFY •THAT I HAVE SURVEYED THE
FOLLOWING DESCRIBED PROPERTY:
/07"—/ZS4 rEG�prws �1. •
AND THAT NO ENCROACHMENTS EXIST—EXCEPT AS
INDICATED. IT IS THE RESPONSIBILITY OF THE
OWNER TO DETERMINE THE EXISTENCE OF ANY
EASEMENTS, COVENANTS, OR RESTRICTIONS
WHICH DO NOT APPEAR ON THE RECORDED SUBDI-
VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD
ANY DATA HFOR
OF FENCE LINES,NOR FORBEDTION ESTABLISHING CBOUND-
ARY LINES.
SCALE:
SEWARD & ASSOCIATES LAND SURVEYING 6 9 4— 0 8 2
DATE:
/y
GRID:
"2-'4" 6sp
FB:
DRAWN:
votior000k
;1rOF A I. ►t
a
•
•• • Duane Mark Seward• 1/
Ls - - 6918 •...!..4!)
. 4!
05-27-04 03:31PM FROM -CUE ESI, SGS ENV SERVICES 9075615301
T-539 P.02/03 F-281
SGS'
SGS Reta1
Client Name
Project Name/At
Client Sample ID
Matrix
PWSID
Sample Remarks:
1042857001
Eagle River Engineering
TI SN. R2W, Sec 25, Lot 12913
T15N, R2W, Sec 25, Lot 12913
Drinking Water
0
MI Dates/Times are Alaska Standard Time
Printed Date/Time 05/27/2004 8:46
Collected Date/Time 05/24/2004 11:15
Received Date/Time 05/24/20`)4 14:36
Technical Director J tephe C. Ede
Released r -
Parameter
Results
PQL
Waters Department
Nitrate -N
Microbiology Laboratory
Total Coliform
0.987
0
0.100
Units Method Container ID Allowable Prep Analysis
[.imus Date Date Inst
mg/L SPA 300.0
II (<=10) 05/24/04 JJ
co1/100mL SMI8 922213 A (<=1) 05/24/04 DK,
Jets Pumping
PO Box 773415
Eagle River, AK 99577
(907) 694-6454,
(Billing Information
1
Debbie Todd
Po Box 770411
Eagle River, AK 99577
(907) 696-2503
Job Site Information
Chris w/ Eagle River Eng
15427 Husky Street
Eagle River, AK 99577
(907) 343.2937
Service Agreement
Number:
Order Date:
Service Date:
Technician:
Job Description: 1500g H2O drop + 1000g pump
P.O. Number:
Terms: Net 30
Salesrep; Nikole
Map Book:
Cross Streets: James Way
Job Comments:
Tax Percent:
0
008609
08 -Nov -2002
23 -Feb -2004 12:00 am
Tony
Job Type: Repeat
Map Grid: 66 - -
Lest service 11/07/02 1250g
—Meet w/ Chris from ER Eng @ 2pm for 500g H2O drop, pump tank—
,
Service Type Qty Price Each x 2 Men Tax
Water Drop 1 395.00 No No
Septic Service Under 2k 1 $115.00 No No
Additional Location Comments:
Red stain w/dark brown trlm, dbl car garage,
no #'s, bum barreli in front yard
Pipes on front by Spruce trees between the 2
buildings
Diagram:
Extension Actual
595.00
3115.00
Gallons Planned: 1250
Gallons Actual:
Hose Length:
Double Tank: D
Pump System: 0
Baffles Intet: ❑
Baffles Outlet: 0
NonTaxsbie Total
Estimated Charges: $210.00
Actual Charges:
Taxable Total
30.00
Customer agrees to the terms and conditions printed on the back. THIS IS A BINDING AGREEMENT.
Signature and Title of Customer Representative
Tax Total
50.00
Grand Total
$210.00
Date
Accepted by JRs Pumping Date Accepted
For your added convenience we accept Visa and Master Card payments over the phone.
Ager 30 Days 1.5% WILL BE CHARGED!
7-i3
APPLIi NT FILLS OUT UPPER HAr ONLY
Property Owner �"ss ;jy-� 1 \ ;� i V CJ �'i
Mailing Address . 3 , `1 1 I -
.'-! Coif i I ,) r 1— Zip Code `/ Ci /
Phone
L' ' > '� (J.-
..0
Buyer
/.
Address
Zip Code
Lending Institution L ,
1 r« 1C. (vs(s �,
Address . h rc J 0.51r
1
Iii 1,.-I is :_i ll . Zip Code, rtri'= 2 7
Phone
17'V- %!=77
i' ..),.>•
Realty Co. & Agent
--- /0.—
Address
-
Zip Code
Phone
Legal Description i. I Jr -I - i 1: C:-..
Street Location ...._ . , ,
IV r. d €;u _ ; � ._
Type of Residence
X7 Single Family
❑ Multiple Family No of Bedrooms
-
❑ Other
+j
BY. aZ'ALV
Water Supply
.> Individual
❑ Community
❑ Public Utility -
-
ATTACH WELL LOG. A well log is required for all wells drilled since June 1975.
For wells drilled prior to that date, give well depth (attach log If available).
7 '
Sewer Disposal
X3 Individual -
❑ Public Utility
0 Holding Tank
Well To Absorption Area 4'49
Well to Tank •-F( pv
- �'/1
Year Individual Installed: 1'1 •.
When Connected to Public Utility
;-- /-y
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
Time
Time
Time
Time
Da / /n _
7-1)
Date
Date
Date
Inspector
Inspector
Inspector
Inspector
Field Notes:
w___,V
1(�,
) f
///�//q/ 1
( 3) APPROVED BEDROOMS
( ) DISAPPROVED
( ) CONDITIONAL APPROVAL'
—
DATE el.•—�� '„
'CONDITIONS OF APPROVAL
+j
BY. aZ'ALV
Soils Rating
Date Sewer Installed
7 — € I
Well To Absorption Area 4'49
Well to Tank •-F( pv
Well Log Received
Septic Tank Size /0 Uri
7202313/821