Municipality of Anchorage Page
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: SW ~l 010~ PID Number: 0170~,.¢o7
~eme:LAHAR GANTT Wastewater System: ~ New ~ Upgrade
~ddress:
1~7oo A~HE~%o~ ~b ABSORPTION FIELD
Phone: 3 ~ - 7 7 7~ No. of B~rooms: ~ Deep Trench D Shallow Trench D Bed D Mound D Other
L E G A L D E S C R IPTI O N so, Rating: I, ~ GPO/Sq. Ft. Total Depth from{~ originall grade:
Lei: ~ Block: ~ ~[~Subdivisi°n:~T~ Deplh to pips bottom~ from original grade: Ft. ~r~vel depth be~ath~ pipe Ft.
ownsh[p:[~ ~ Range:,,, ~ ~ [ Section~ ~ Fill added aboveo,original~ grade: Ft. Gravel length:~ I Ft.
Number of lines: Distance between lines:
WELL: ~~ New D Upgrade Gravel depth: ~,~ Ft. ~ ..I Ft.
~lassification (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material: ~--~ 10
Driller: Date ~rilled: Static Water Level: Installer:
~RQTI6 DRILLING I0/~0 ~ a. CARL'S EICAV~T, Dateinstalled:/ /
Pump Set at: Casing Height Above GrouRd: TAN K
Yield: l ~ GPM Ft. . Ft.
SEPARATION DISTANCES ~Septic ~ Holding ~ S.T.E.P.
TO Septic Absorption Lift HoMing ~Prlwlo Manufncturor: C~paoily in gallons:
Fram Tank Field Slatio. Tank Sower Lines ~NC~. %ANK' 2000
Material: Number of Comparlments:
Well IO1 JOE ~ ~ 80 ~TEE L
s~c~ LIfT STATION N.
Water ~]OO ~/OO ~ --
Lot Size in gallons: Manufacturer:
Line 3E ~7 ~ --
Foundation 2 ~ ~0 ~ ~ 0 "Pump on,, level at: "Pump off' level at: High water alarm at: __
CurtainDrain ~ .... Pump Make & Made] Electrical. Inspections performed by:
Remarks: O~q}~( _..~¢~...~ F.~,~ BENCH MARK
~ I Location and Description:
Assumed Elevation:
~ ENGINEER'S SEAL
-,-R~ ~ ~ j~,~, Flattop Technical Semi(
Inspections performed by: FLy.Dp T~c~ svcs. Dates: 1st
Department of Heal.and Human Services approval
Reviewed and approved by: _ __ . .... Date: .7-
.......................... ~ :~
72-013 (1/91) MOA 25
Permit No. ~W' ~ J C) I o.5' _ Page
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744'
On-Site Wastewater Disposal System and/or Well Inspection Report
LegalDescription: J- ~ [~)Lk' bt ~NI~ ~"T<~ S/D PIDNo.:
lo' UTILIT',j EAs£i~ENT
Lo'r ~ ~LOCK' D
O
0
L
Lo'T &
I S,T, CO,
TR~H C,o,
82
~. A'TH~'RTON Rb
WELL
Flattop Technical Services
14530 Echo Street
Anchorage, Alaskcr 99516
72-013 A (2/91) MOA 25
ENGINEER'S SEAL
Permit No. ~k/ ~/O ICL_,( Page ~ of ..~
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAl.. SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744'
On-Site Wastewater Disposal System and/or Well Inspection Report
LegalDescription: L '7. 15LK b, I<NIK I-{TS ._¢,/b PIDNo.: OF703,5"O'7
q5
~5
2ooo d-/~L --
SEPTIC TANk
INVERT ~LEV:
OUTLET =
72-013 A (2/91) MOA 25
~',LEV = IO0, o /
flg.o /
FABRic
SCALE:
VERTICAL
· . Flu[top Technicctl Sez~ices
14530 Echo Street
;[nchorcrg-e, A.]cmkct 995]R
ENGINEER'S SEAL
. ?~-% of:/~t'-%
,~...~,~, ........
.,,%x':..,. ~ '..:.~¢%
~.~..:~:'..-;.':..'. .....
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW910105
DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES
OWNER NAME:GANTT LAMAR L &
OWNER ADDRESS:12700 ATHERTON RD
ANCHORAGE, AK 99516
DATE ISSUED: 5/17/91
EXPIRATION DATE: 5/17/92
PARCEL ID:01703507
LEGAL DESCRIPTION: KNIK HEIGHTS BLK D LT
SEC. 27, T12N, R3W, SM.
LOT SIZE: 43500 (SQ. FT.)
NUMBER OF BEDROOMS: 6 THIS PERMIT: 2
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80).
3. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
RECEIVED BY:
DATE:
ISSUED BY: DATE:
/ 5 T
'3.4
LOT '7 BLOCK'
'T. ~1.
2oo0 G4 ~ ,,//"
~fo BE RE_~OVEb
~'0 P~EC o M E~~
WELL
NI
LoT G
FuTuR~ RE I~L ,qcE t4 E ~¢'r
5¥$T ~t4 LOCA'T ION
~OU~
~/00 ~
iqS~
A FHF._.RToN ROAb
14530 Echo Stree[
£h:chozaqe, Alas?.c~ 99E
L-I. BLKb KN\K FI'TS $/b
SEF"TIC S"/STEN1 UPGRAbE
SITE PLAN
SCALE: 1'=sO~
5URVE'{£D PLAT. ALL
A
NEw 'TRENCH ~[~
S~C¥' l © N
:Flattop Technical Services
14530 Echo Street
Anchoraqe, Alas!~_a 995Ifi
L T, BLK I3 KNIK gT$ $/b
SOIL ABSORPTION -1-RENCF
PLAN ¢CROSS SECTION
SCALE
CIVIL & ENVIRONMENTAL ENGINEERING · ENERGY CONSERVATION & ANALYSIS
THEODORE F. MOORE, P.E. 14530 ECHO ST.
PH: (907) 3454355 May 13, 1991
ANCHORAGE, ALASKA 99516
M.O.A. DHHS
P.O. Box 19-6650
Anchorage, AK 99519
Dear Sirs:
This is the requked design nan'ative to accompany the sewer upgrade permit application for Lot 7,
Block "D", Knik Heights S/D. Copies of the soil test results and and design drawings are enclosed. The
proposed upgrade is from 4 to 6 bedrooms. The existing soil absorption trench was sized and approved
for 4 bech'ooms at the time of it's construction in 1984, and in 1991 the fluid depths were consistent with a
normally operating septic system. The proposed trench upgrade will provide two bedrooms worth of
additional capacity. To upgrade the existing 1250 gallon septic tank to six bedroom capacity would require
the addition of another 500 gallon septic tank, however our measurements indicate that the existing tank is
only 96 feet from the well. Rather than apply for a waiver, or try to move the 7 yea' old tank, we intend to
replace it with a new 2000 gallon septic tank located outside the 100 foot radius from the well.
As can be seen from the soil logs, the subsurface soils are excellent for construction of a soil
absorption system. The soil rating based on the measured 3.6 minutes per inch in test hole #2 is 1.2
gpd/sq, ft., which for a two bedroom upgrade requkes 300/1.2 = 250 square feet of sidewall at'ea. To
obtain this, while optin-dzing usage of the best material, we have designed a 25 foot long deep trench in the
vicinity of test hole #2, with the sewer gravel beneath the disn'ibution pipe extending between 8' and 13
feet. On the site plan we have designated a 75 foot long replacement ~ench with a 20 foot gap spanning
the area of the presently proposed upgrade. This is only one conceptual plan, and the lot size coupled with
the good soil conditions demonstrated by the test holes allows for many options.
The topography in the proposed construction area slopes gently to the southwest at approximately 5%.
There is no observed surface drainage within 100 feet of the existing or proposed system.
The proposed project will have no measurable impact on wells or wastewater disposal systems on
adjoining lots. ,Nor will it have any impact on reserved space/surface and subsurface, or on di'ainage.
Please give me a call if you have any questions on this design.
Sincerely,
Ted Moore, P.E.
Flattop Technical Services
14530 Echo Street, Anchorage, AK 99516
Phone (907) 345-1355
Lot 7, Block "D", Knik Heights S/D
12700 Atherton Rd.
Wastewater disposal system installation
Specifications
1.0 General:
1.1 The scope of the project includes replacement of an existing 1250 gallon septic tank with a new
2000 gallon septic tank and construction of a 25 foot long soil absorption trench with 5.5 feet of sewer
gravel to supplement the existing soil absorption system.
1.2 Construction shall be as depicted on the approved site plan and design di'awings. Minor
deviations from these di'awings may be allowed or required by the engineer conducting the inspections.
All construction procedures and material specifications shall conform with Municipal and State
requh'ements.
1.3 All separation distances shall be in confom~ance with Municipal requirements, unless specifically
waived.
1.4 The contractor shall be responsible to obtain any necessm'y utility locates, and to work around any
buried utilities.
2.0 Septic Tank:
2.1 The existing septic tank is to be abandoned by pumping, removing, crushing and burying on site
at a location outside the consU'uction area and more than 100 feet from all wells. A new 2000 gallon septic
tank is to be installed at the approximate location shown, with pm'ticular care being taken to ensure that all
portions of the tank m'e mom than 100 feet from the well.
2.2 The septic tank shall be Municipally approved with a minimum of two compartments, and shall be
set level on undisturbed soil. Each compartment shall be equipped with a watertight manhole cover and a
4" cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial
type, rigid insulation.
2.3 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The
waste line from the residence to the septic tank shall have a minimum slope of 1/4'" per foot, mid the waste
line between the tank and the soil absorption system shall have a minimum slope of 1/8" per foot. A
double cleanout shall be installed within 5 feet downstream of the septic tank.
3,0 Soil absorption system upgrade:
3.1 The soil absorption system upgrade shall be coustructed by excavating a trench in the approximate
location shown to a depth of 13 feet. The beginning of the trench shall be no closer than 5 feet from any
portion of the existing n'ench.
3.2 The bottom of the new trench excavation shall be level. Any compacted or smeared surfaces shall
be raked to allow proper infiltration.
3.3 A total of 5.5 feet of sewer gravel shall be placed in the trench, with the bottom of the horizontal
distribution pipe set level 5 feet above the bottom of the gravel. Sewer gravel shall be 0.5" - 2.5" screened
gravel, with less than 3% passing the #200 sieve. The perforated distribution pipe in the existing trench
shall be disconnected from the existing sump and rerouted around the sump, with the sump remaining as a
monitor tube in fire existing trench. The perforated distribution pipe linking the two trench segments shall
incorporate a 2" bump (rise) in the line before descending to the level of the second trench. Approximately
12 inches of sewer gravel shall be placed beneath the perforated pipe linking the two lreuch segments.
3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on
the design ch'awings. The portion of the monitor tube extending through the sewer gravel shall be
perforated.
3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel before
backfill.
3.6 The top surface of the cover material shall be mounded 6 inches higher than the sun'ounding
ten'ain to allow for subsequent settlement, and sh,'dl be graded to smooth contours. Fill slopes shall be no
steeper than 3:1.
4.0 Inspections:
4.1 A total of 4 engineering inspections will be required during the course of the project: (1) initial
stakeout with the contractor to establish the location of the system and to discuss the plm~s, specifications
and construction procedures, (2) after the native material has been excavated to expose the infiltrative
surface to ensure that it is level and at the fight elevation, and confmrns with the soil test information, (3)
after the sewer gravel is in place and the distribution pipes have been laid and connected up to the septic
tank, but prior to placement of filter fabric, and (4) after final backfill and grading is complete. The septic
tank requires one inspection after it is set level and the piping connected, but prior to backfill. This
inspection may be incorporated with any of the above inspections.
4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in
advm~ce to ensure the availability of the engineer.
PERFORMED ~OR:, 5/~f?A
Flattop Technica! Servfces
14530 Echo Street
Anct~orage, Alas]ca 99516
Munlclpallly of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
'T,~t.~ I
dANTT'/MAR k' 5_WANK
LEGAL DESCRIPTION:
1
2
3
4
5
6
7
8
9
10
11
12
~..(- f 13
: 14
15
16
17
-~ 18
~,,~.
19
20~
COMMENTS
L 7,
BLk' D, /(t4t[< HTS
REDDISH 5ANDY LoAM
GP BRowN, 5LI~TL"/ SIFT"/
Township, Range, Section: .5_cC 2'7., TI2t'l_, RBW'
SLOPE
M L (~ RA'/
SAra, bY 51LT
WAS GROUND WATER
ENCOUNTERED?
No
S
IF YES, AT WHAT OL
E
GRAV;LLW 5jl~,b Depthl0 Wal~rAller 18 ~ ~.~.L,
Moniloring? bRy Dale: ~JI3/RI
5P UNIFORM
SITE PLAN
Reading Date Gross Not Depth to Net
Time Time (k ¢,fl Water Drop
q:32: 3o 2~ '/~
ST4~ q: S ~ 2 S
+B~O Io:o3:30 2q 3/~
+R~o lo.. ~fl 2~
PERCOLATION RATE _ 7 (mmules/inch) PERCHOLE DIAMETER
TEST RUN eETWEEN '7. O FT AND , '7,~" .FT
PEFd-ORMEDDy: ~LATTOP T£¢1(. 5FC5_ - i _q~,.~'~/~,~. CUIIIIy ItIAI 1HIS ] EST WAS PERFORMED IN
AGCORDANCE WITH ALL STATE AND MUNiCiPAL GUiDELiNES iN EFFECT ON THIS DATE. DATE: _.__~'/ /..~/¢/
72'008 (Rev. 4/85)
LEGAL DESCRIPTION:_ L
pT
1
2
4
8
9
10
11
12 5~ CoA~
13,
5ANb
14
15
16
17
18
19
20
I?lattop TechnfcaI Services
14530 Echo Street
Anchora,"re, Ala¢,,'a
Municipality o! A~J~o~ag~
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
8OIL8 LOG -- PERCOLATION TEST
dAN~,/~AR~ SWJNK
DATE PERFORMED:
SLOPE
Township, Range, Section: SEC 27_, TI2N
SITE PLAN
511-TV S~b --
$o ME
SANb
WASGROUNDWATER
ENCOUNTERED? NO
s
IF YES, AT WHAT L
DEPTH? _ ~,~. pO
E
Deplh lo Water Alle
Reading Date Gross Net Depth to Net
Time Time ~,,, t N") Water Drop
1_.2" PR~:~OA ,~/b/~! Io: 2fl::Zo
START lO:3g: co 2~ 2/8
~2 io:~:3o ,%-.
~H~o ~_ lo: ~gto~ 2q
o:~; co ,t Z ~,4 I ~,/8
PERCOLATION RATE ~.(2 -- (minutes/tach) PERC HOLE DIAMETER ~
TEST RUN BETWEEN ~ .5' _ FT AND ~ . FT
.FkA~'oP m£c~/ $Vc5_
-- CE~tfll y Il-IAI 1HIS 1EST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: -'J2"'"/,{,.3 / ~? /
72;008 (Rev, 4/85)
IVil. h\IICII,AL I'FY O~:
D[!PARTMENT OF H',!AI.TII &, E['~V!!-.tO!\'.itqFIXIT/,I Pt?OTEC.'I ION
E N V I R OF, liv~[-~ FITA !. }: ,~Gil\l E E FUN G
825 I. Slreet-Anchnra~e, Atnsk~ 99501 Telephnna264-4720
ON-SITE SEWAGE DI,~POc, AI. SVSTEF~ AND/OF( WEN. iNSPECTION REPORT
~ LIPGRADE
. _ .L: .~/¢,
LEGAL DESCRIPTION
LOCATION
...... ] -[ Well rAbsorption area
0 / DISTANCE TO: J
~ [ Menu fa~ul-e~ - '-- .
Inside
length
.... ~ ~_ ~ Z) [ IF HOMEMADE:
Dwellings,?_ / /
Material
NO, OF SEDROOMS~-~
PERMIT NO.
Width Liquid depth
Dwelling PERMIT NO.
Liquid capacity in 9allons
' Foundatiorl
Total length oflines
_ _
Material beneath tile
Depth
]Material
'/N ea r'---~sTI o t line
J Tiench width
PERMIT NO.
Distance between lines
Total effective absorption area
PERMIT NO.
Crib depth Total effective absorption area
Building iroundation Nearest lot line
Driller Distance to lot line PERMIT NO,
Sewer line Septic tank /Ab~ area s
[
[ Well
DISTANCE TO:
Manu facturel
DISTANCE TO: / I ~Z ~t
~-- -
~ Z. / . ~_
Type of c~~ Crib diVine\e,-
DISTA~C[ TO:
DISTANCE TO ~]g T~datio;
OT H F R
'--PIPE MATERIAL§
)/'/~.s/7 ,c
SOl L TEST RATING
io,2.
INSTALLER
REMARKS
APPROVED
Dt LEGAL
/0'/o -g'::
72-013 (Rev. 3~78)
MUNICIPAI.iTY OF ANCk!ORAGE
DEPI. dX: : &
EN'qlRONL,'Li'4 , , C'I'ION
m} 0 5 0
RECEIVEi)
[. E.I. Iq~. 1 i' ~:.[, '1 (' ,EFILTH Fff',l[) EN"/IF.':ONHEN'FFIL ~ ,'ECTI'ON
_, [F.'.EE1., F~NC:HOF:FIt3E. Ffl<. S~95EI:l.
264..-472'F~
,:: :.~n..lu;~l,¢E;:[ ',
FIF'F'L l :'." I:::INT ...TERF%IL.[:, H. HFINS;EN F'O Lq[I,.,
L l::l I:1: I:l T I I:.:1
LEi:}RL L:iZ:T 7" EILOC:[~:: b F.:l'.,I J: k:: FIEITIq:FS Z;, [. LOT '.'-~;IZE
'T"¢F:'E OI:.~ S']]'L FIB2;C~F.':F'TIEIN S¥:-];TEH I'S' TRENCH
FEET
t ll'-h',[llJI1 NLIHE~EFi: r"~F E:E[:,F:OOHS; = 3: :'~;IZIIL. RPTINa <2:E.! F'l,. E,[ ...... ::Ld.:¢
THE FtlE(..'.!UIF;:ED ~,IZE OF THE SOIL ..... ,,'"
HE,--,- ~ F ] I ON '-" "~'
.:, -r .::, TE H I '_,.'!;:
THE LENI3TH [:,tHENSIt.')N IS THE LENI3TH ,'ZN FEE:Y) ElF' THE 'FRENIZ:H :~;' C,F.:RINFIELD.
THE: DEF'TH I:)F R TRENCH 3F' F'II' IS:; THE [:,I'.-7, TFIN':E E~E'THEEN THE SLRFFtCE OF THE
GI:;:OIJN[:, IhND THE En)TTEff,'I OF THE E:,.0.'.:R',,,'FtTI"N <IN FEET>.
IIIE[..E I:5 NO :SET 1.4ZDTI-~ F'CIF.: IF.t'ENE. HE::,.
THE GF~:F'I',,,'EL [:,EF'TH IS THE HINIHUH DEF"I'H OF 3Fi'FI',,,'EL BETHEEN THE OLrTFFtL. L PIPE
RN[::, THE E~FI'TT'.'iH OF: THE E;:-:iI_-:FI',,,'FITION ,'IN FEEl"',.
I I.: F. I 1 .[ 1 , :',= ........ . . .., ~ ~ .,
~' FI L [ .I"INT I"IFIS THE RE._F ...I',I.:,IE, ILI'f ~' TO INFCF."H 'n"l~5 r. EFH[~.I I'IENT [:,l..IF,.':II'.,l(!i THE
.]:i'-,I:5"FFILLFtTI ON II'.,ISF'F'CTTONS_ L-IF FIN¥ HELL::,': '- RDYFIC:ENT TO THI':'_, FF.'"'_FE~..';'I'~ Fff',![:, THE
I'-,ILIHE:I!:~F;: OF: F;:ES:; I [:,IEiqCE:~, THRT THE
E:FIC[:::F'ZLLING OF FIN'.? 9"r'"'i;TEH I,.I'rTHOUT FTNFIL ].N.:~ E...I ZON RNF.:,
· r. -, .... FIF'F'F~' ._. ',,,'RI.. B'¢ TH .'[ :5
I...[:.I.HI.TIIENI HILL E,[. SUBJ'ECT TO Fl; .::,[:.L. LIT][L~N.
l',l:l:l'.,IZt'.lt...ll','t I)ISTF:INC:E []:E:I"HEEN R 1.4ELL RN[.', RNU ON-SITE '-:,EHFIGE [:,IE;F'OSRL
"" JF: "L~;F~ TO 2~:~R FEET F'F..:Off FI F'IIBLZC HELL [:,EF'ENE:,ING
:1.8:!) ,~::EE:T I-.1'. FI F'I;.:I',,,'FI"rE HELL '"
I.IpiN THE T'¢F:'E AF F'IJBLIC HELL. -
I"IIN]:HL.IFI [:,I~;'FRNCE FI",i'.Cd"I FI F'F.':I',/FITE HELL TO R F'F::I'v'FITE 2;EI4EFi: LiNE I."5 25 FEET RN[>
TEl R COhff'IUNIT'.,.' S:;EHE:F..: LINE: IS ~.~3 FEET.
HEL. L. LCI(~S FIRE I:;~IEQUIFtED F:IND h'IUST DE RETUR'NEL':, TO THE DEPRF~tTP1ENT 14ITHIN
CIF THE HELL COHF'LETION.
OTHER Fi:EI~LIIRE. HENI"S HR'~.' FIF'PL'¢. SPECIFICRTION2; RNE:, E:ON~T~tUCTION DIFIGF'.RHS RRE
FI',,,'FtILRDLE TO :[NSI.JRE PROPER INZ~TF:ILLFITION.
..1::1. I II r 'THI::I'T'
1' Z I:::11'"1 FRP'III._IFIF;: I.,.IITH THE F'.E'.-.~. iREHENTS FOP
F:'OF;:"FH EW THE I"ILIN ]: C.: I F'FIL I T"r' OF RNC HC Fi'FI
2: I HILl.. II"~S;TFILL THE S"r'STEP1 IN I":IC::EF"E:FINL-'E HITH TFIE .":EE:'ES;
:ii:: I UNE:'ER:i~,I"F~N[:, THFIT THE ON-L:;.'[TE-",EllER'-' ' ' S~?STEH HFW F"E- ..........IF'-I::. ENLRRGEHENT IF' THE
F:E2; I DENC:E 1:5 t;:EI"IC~[:'EI..E£:, TL'I I NL-:LLIr:,E [,ICJF..E"
NED:
J:"iF'PL ]: CFff.4T ..I'EF.'.F..:.'] L[, I.,.I. HFINSEN
F'ERHIT NCL
FiF'PL I C:F~HT ...j. F2 ~" K 0 l c~
[._ 0 C:£~ T I
[:,EPFtRTMENT
:325 ,_" S'T'FtEET, RNCHORF~,Ci[£, FtK. b. ,01
264 -,l 720
HEr;fi_TH
TYPE OF SC IL 13DSORF'TICIN S~r.S'rEl'l
MFt::.::IP1UM HUME:ER OF E:EDROOM% = .]~
TtaE F:EC~I...I[RED SIZE CIF 'THE SOIL. FH.:rSO~t'F'TION S"r'STEt'I TS:
:: b. EE 1"-4 ~]~ '~- I-t =': ~ ~]'i F:: F:t '...' E: L_ [:, FZ F' -F' F4
c, E F' T H 'D
THE I_Ei'.IGTII [:,IMENSIOt'I ItS THE L. ENG]'H (IN FEET) OF Tt. tE TRENCH OR DRFIIHFIE:LD.
THE DEPIH OF FI TRENC:H OR PIT IS I'HE D~STFINCE 8FTHEEi'-t ]'HFS. SUF,'FFIC:F: OF THE
GROUH[:, FtHD THE POTTOM OF' THE [E>::CR'¢RTION (IN FEET).
THERE IS NO SET HIDTH FOR TRENCfiES
THE GRR',,,'EL DEF'I'H IS THE MINIMLIM DEPTH OF GRRVEL E:ETHEEN I'HE OUTFRLL F'IF'E
K]HD TI4E E¢O]TOH OF THE [SXC:RVRTIOH (IN FEET:,.
PERM[ T RF'PLICIgNT H[~S THE RES;POI.ISIB I L I T'¢' TO It'~FO¢;:M 'FI4I_'S DEF'F'IRTMEHT F:, .tRIt,l(] FHE
it-4:SfF~L. LF4TION IHSPECTIONS OF K4N'-? HEI.LS FIE:,JFICEHT 'FO 'THIS PF:OPERT"r' RN[" THE
NUIdSER OF FrESIOEHF-I~S TI'IRT THE HELL HILL SERVE.
DflCKFILLINr] OF' RN'¢ _~-:TEtl [,~[THCII]T [:'If.~,CiL IN'..~F'ECTIOH FIN[:, FIPF'ROVRL E',"r' THIS
[:,EF'RRTMENT HILL E',E SUE;JECT T0 F'RCPSECUT~FIN.
HIHIMLIM [:,I5"FFtNC:E DETHEEH ~ HELL RND RHY ON-SITE SEHRGE DISPOSRL S',r'STErq IS
180 FEET FOR R F'RIk,'RTE HELl_ OR ±50 TO 200 FEET FROf. IFt PUBLIC HELL £:,EF'EN[',IHG
UF'CIt~ THE T'¢F'E CIF F'LIE:t_iC: FIEL[_.
MIHIMUM [,I:.~;l'iqNCE FROM R F'RIVR'TE HELL. TO R PRI'v'RTE SEI,IEF: LIHE I:S 25 FEET
TO F-t CC~MP1LIHI'T'.~' SEHER LIHE 1S 7r5 FEET
HELL LOGS F~F:E F:IEI]UiRED RH[:, MUST E',E RETUR,*IE[:, TI] 'rile [:,EF'FIRTMEHT HITHIH ]'0 [:,R"r'S
OF lift:- FtEL. t_ C:OMF'LETION.
UTHER F:EC!IJIF'EMENTS t'IRY F¢:'PLY SF'ECIFICFtTIOHS RN[:' C:EINS;'fF.%IIZ:TIOH DIF~Gi;:RI'IS RF;:E
R',,,'/'~iLRBt_E TO INSURE PROPER INSTRI_LRTIOH.
I C:EF:T IF'¢ TFIFtT
] I Fff'l FFd'IILIRR HITI4 THE REQ_.IF.'EMENTS FOR: I]N-S.[TE SEI,]ER:S RNC' HELLS RS SET
FOF:-Ft4 D,'¢ TI4E MLINICIF'FtLIT'~ CIF FIHCHC¢;'~GE.
2: I 14ILL INSTF~LL. THE <-"~' -
.:,,:,rEt1 IN RCC:ORC'FtHCE l'lI TH THE CO[:,E~.
~' T UHE',EF:STRNC, THFFT THE CN-S]TE 5EHER :~:TEI1 HR'¢ F:E~!U~RE ENLRRGEHENT IF THE
S I ] H~'D . .......................................
I SE;I_IE[:, [:,F~ T E_._ ~ . ',/4. E~
~: MUNICIPALITY OF ,',,NCHOR~GE
~:.~,,~ ,.,,~ DEPT. CF
September 2S~ 1978 ~NVIROI',4,,C CTION R&[~ Xo. 851148
Syren & Sons
2330 g. Tudor Road
Anchorage, Alaska
RECEIVED
Subject: Soil Investigation for Sanitary Sewer System, Lot 7, Block D, Xnik
Heights Subdivision, Anchorage, Alaska
Gentlemen:
At your request of September 20, 1978 we conducted a subsurface soils inves~
tigation at the proposed location of the sanitary sewer system on the subject
lot. The investigation complied with those procedures required by the Munic-
ipality of Anchorage Department of Health and Environmental Protection.
This investigation, which was accomplished on September 21, 1978 consisted of
a test hole excavated to a depth of 16 feet below the existing ground
surface. The test hole was sited according to your instructions and its
location is shown in attached Drawing A-01. Excavation was accomplished with
a backhoe.
The topography at the excavation site is generally gently-sloping to the
west. At the time of investigation the site had original vegetation con-
sisting of spruce, birch and brush which had been partly cleared. The top of
the test hole was located at original ground surface.
The soils encountered in the excavation are shown in the test hole log in
Drawing A-01. This log displays specific conditions encountered at the test
location. However, subsurface conditions may vary in other parts of the lot
without any apparent surficial evidence of the change. Groundwater was not
encountered. Bedrock was not encountered and at the time the hole was exca-
vated seasonal frost was not present.
Based on tile visual classification of the soil and the requirements set forth
by the Muncipality of Anchorage, a percolation test was not necessary within
the test hole on the subject lot.
September 25, 1978
Syren & Sons
Page -2-
We appreciated this opportunity to be of service to you. Please contact us
if you have any questions concerning this letter or if we can be of addi-
tional service.
Very truly yours,
R?ONSULTANTS, INC.
Sent4or Geologist:
GS/djb/12-O
E~ORING NUMBER
1 Date Completed:
SOIL DESCRIPTION
_ __ Q/~G3%NI._C_ ~T.EBI_A~L ...... 1.0 '
SANDY SILT (MI,)
brown
3.0'
SANDY GRAVEL W/
TRACE SILT (GW)
gray-brewn
sAt~ (sw)
fine, gray-brown, moist
scattered lenses of
fine-coarse sand w/
some small gravel
.................... _14.0'
SAND with lenses of
gray SILT W/TRACE GRAVEL~~/
(SM) moist
_16.0 ' '.P.D.
No Groundwater Encounqered
LOCATION SKETCH No Scare
-L ~Test Pit
NOTE; DISTANCES SHOWN ARE APPROXIMATE AND HAVE
NOT BEEN MEASURED BY SURVEYING METHODS.
EXPLANATION
ORGANIC MATERIAI~--'m
Litl~ '~'isi'ble Ice 0:10' Vx
~-- ICE D~$ORIPTION
'SAMPL f NUMBER
SS, 72, 5Z I°/o, 85.9 pcf
[ ~' BLOWS/FOOT
--L--~PnO~ srnAr~
BEOROCK
SOILS
LOG
,[ A a-AhT£n BO,,T/HG
SAMPLER TYPF SYMBOLS ]
SOIL
SYMBOLS
Lot 7, Block D
Knik Heights Sudivision
Anchorage, Alaska
:. N 0. 851148
MUNICItALI%Y OF &NCHORAGE
DIVISION OF LNg~.ROKBiEN]?AL HELALTH
DF/~ARTMENT OF HEAl,TH lIND ~It~MENT~ PK~P~TI~
APPLIf~TI~ ~R ~AL~[~ ~THOR_.~Y ~PROV~ CEI~II[ I~E
1. ~rv~ral infom~tion Application Date ?,:,, , .~"~/
(a) ~gal ~sc~'iption (include lot, block~ subdivision, ~ction~ t(~nship, range)
Location (a~¢~Kess ow directions)
'~, '7 .:?~'~
(c) Applicant is (chedi~ O~:~) r~nding Institution ~:hez, ~
(d) kmding Institution
Address
(e) Real Estate Co. & Agent
Address
Te le phone
Nt~ber of Bedrcort~ .......... //
Othet~ _(jdf~½? rj~ _b~_ J .................................
--Water, S u_q p_p!y~
Note: If c~z~niCy %~11 system, must haw wL, itten oonfirllmt, ion f~cm the State
Depa~,hmnt of .~vironn~;nta]. Conservation attesting to tk~ legality a~d status.
Is the ~11 adec~]at:e for the nur[~er of h]¢lrcx]ns specified ir] this HAA
/
Is the wastewater (tis~)sal s,/stem adequate fo~ the num~t off ~dr~ )
2-15-84
Firm Providin_oil~_n_spections, '£~sts libra and Information
I certify that I have checked, vez, ified, or conforlred to all MOA [~3k CmJ. delir~s in
effect on t~ ~te of ~is ins~ct, ion~
/
Sigrmd biz
( ENGINEER SEAL,)
6. DHEP Ai~orova].
/ /
Approved for y back~oo]'~~.
Approved~[2~.. Disapp~,ove d
Termg of Conditional Appz{oval
conditional
l~.]te
%he Municipality of Anchora.~ Department of Health and Enviror~ntal Prrotection d~s
not 9uarantee t~ continued satisfacto~y t~rforr~nc~ of tP~ water supply and/o~r the
was~wat:e~ dis~sal system. ~is approval indicates that,~ as of t~ validation ~te
shc~ a~w~, ~d on tl~ data and info~,~tion f~nished t~ an engir~er reoistered in
the State of ~aska, ~]e v~tte~ supply ~]d wastewater disposal system is safe and func-
tional for the rnn~]~ of ~dr~m ~d tyF~ of struct~,e indicated~
( DHEP SF, J~., )
7. Mail the ~La_A to tim fo/t~aing address:
KB2/d5/s
[Page 2 of 2]
2-] 5-84
MUNICIPALITY OF ANCF~DRAGE (MOA)
HEALTH ~3THORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
i; tii 'iL
Well Log P~esent ~.~..)
Total Depth / ~ .~z~' Cased to
Static Water Level
Casing Height Abo~.~ Ground
Electrical Wiring i~n Conduit4~)
Separation Distances f~om Well:
To Septic/Holding Tank c~ Lot .
If A, B, or C, D.E.C. Approved(Y/N)
Date Completed_ l~9/~L~ Yield ~,¢~L
/~-/ Depth' of G~outing ..
Pump Set At /~/~ /
¢~. /. ~ / Sanitary Seal on Casing
Depression A~ound Wellhead
~ ~' ; Or~ Adjoining Lots,,, 1,~/~::~,~9" ~'¢-'''-'
To Nearest Edge of Abso=ption Fie:Ld on Lot .y-/f)O/ .; On Adjoining I~3t~
To Nearest Public Sewe~ Line A3 j.~- To Nearest Public Sewer
Cleanout/Manhole ~Jj.~__j~ ....... To Nearest Se~l~..~ Service Line on Lot.
Water Sample Collected By ~~ ; Date ~/~
Water Sample Test ~sults
B. SEPTIC/HOLDING TANK DATA
7~/90/ Si?~ /2lb-O No. of Compartments
Date
Installed
Standpipes.¢~N) Air-tight Caps ~N) Fou~datio~] Cleanout~.)
Depression ove~ Tank JY~) Date Last P~mped ~/~/~¢ .
Pumping/Maintenance Contract on FileJ~/N).~/4 ; for
Holding Tank High-Wate~ Alarm (Y/N) ~//¢-- Temporary Holding Tank Permit (Y__=/N__)~//~-.
Separation Distances f~.om Septic/%lold:Lng Tank:
To Water-Supply Well _~ /j~! ~," To Building Foundation ZO '
[Page 1 of 2]. "'
To Disposal Field ..... ~/
To Stream, Pond, Lake, c~ Major Drainage
2-15-84
C. ABSORFI'ION FIELD DATA
Soils Rating in Absorption Strata
/
Date
Installed
Width of Field
Square Feet of Absorption A~ea
Depression ove~ Field (Y~
Results of Last Adequacy Test
/~P~ ~ Type of System Design
Length of Field _.. Z/y
Depth of Field
Gravel Bed Thickness
Standpipes P~esent ~/N)
pete-of quacy Test
Separation Distance from Absorption Field:
To Water-Supply Well_ ,~-/~p / To P~ope~ty Line -/-,~p/7~
.To Buildin(.~ Foundation ~ ~ To Existing or Abandoned System
Lot ~3 .l~c~- ; On Adjoining Lots ~, ~-~9/
To Water Main/Service Line . ..p~/ . To Cutbank(if present)
To St~eam/Pond/Lake/c~ Major D~ainage Course ./-/~O / ~
To D~iveway, Parking A~ea, c~ Vehicle Sto~age A~ea ~/9/' ~
/
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Wate~ AlaFm Level at
Tested for
Electrical Codes(Y/N)
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles du~ing Adequacy Test.
Meets MOA
Comments
** Check Permitted Bed]room Rating Against HAA Request **
I certify that I have checked, verified, o~ conformed to ali. MOA HAA Guidelines in effect
on the date of this inspection.
Signed ~'~.4.. -w~l.~"V''
KB1/OS/s
Date
MOA No.
[Page 2 of 2]
2-15-84
ALASKA iUIROFImenTAL COFITROL Se dlCE$, IFIC.
En§JncerJnq $ Enuironmenlal $1uJies
JUNE 8 1984
JERRY & EVELYN HANSON
12700 ATHERTON ROAD
kNCHORAGE AK 99516
SEr/SER - JERRY & AYELYN HANSON BUYER - LAMORE & SARAH GARITT
SUBDIVISION - KNIK HEIGH'I~S BLOCK - D LOT - 7
ADFJQgACY TEST FOR S~INER SYSThl~I
~ TYPE OF ABSORPTION SYSTEM IS A TRENCH WITH AN AREA OF 480 SQFT.
THE SYSTEM IS CAPABLE OF ACCEPTING 600 GATgONS OF WATER PER DAY.
THE SURGE CAPACITY OF THE SYSTEM IS 944 GALLONS.
BASED gPON THE TEST DATA ~E SYSTEM IS ACCEPTABLE FOR A
4 BEDROOMHOME.
THE SEPTIC TANK WAS P[IvIPED 0N6/8/84 .
~VJOW TEST ON WELL
THE WELL FLOW RATE WAS 4.9 GPM FOR 3 HOURS.
SEPTIC TANK ADEQUACY
THE EXISTING SEPTIC TANK VOLUME OF 1250 IS ADEQUATE FOR
THIS 4 BEDROOM HOUSE.
I . DATE RECEIVED
I NSP ECTI 0 N APPOINTM E~T~,.., ,_,
TIME TIME \ \ ~J TIME
DATE DATE~'~, ~,~ DATE
INSPECTOR I NSP ECTOR INSPECTOR '
MUNICIPALITY OF A~CHORAGE DEPL OFHEALTH&
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTE~NMENTAL PROTECTION
825 L Street - Anchorage, Alaska 9B501
ENVIRONMENTAL SANITATION DIVISION MAY 2 6 198i
Telephone 264-4720 R [ C [ J V E D
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
DI RECTION~: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing.
1. PRORERTY OWNER PHONE
MAI L~G ADD.SS
2. BUYER PHONE
MAILING ADDRESS
~ENDI~G INSTITUTION PHONE
4, REALTOR/AGENT .... ~HONE
MAILING ADDRESS
5. LEGAL DESCRIPI'ION
STREET L~C/}TION
6, TYPE OF RESIDENCE
SINGLE FAMILY
[] MULTIPLE FAMILY
NUMBER OF~BEDROOMS
~ One E~ Four
E Two E-] Five
E~ [] Six
Three
[] Other
7. WATER~UPPLY
iNDIVIDUAL*
[] COMMUNITY
[] PUBLIC UTILITY
* ATTACH WELL LOG. A well log is required for all wells drilled
since June 1975. For wells drilled prior to that date, give well
depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
//~ INDIVIDUAL/ON-SITE'*
[] PUBLIC UTILITY
YEAR ON-SITE SYSTFM WAS INSTALLED.
NOTE: THE INSPECTION FEE IVIUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010 (Rev. e/79} '{~a I 9~,~
THIS SIDE FOR OFFICIAL USE ONLY
1, TYPE OF RESIDENCE NUMBER OF BEDROOMS
[] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER
[] MULTIPLE FAMILY [] TWO [] FOUR [] SIX
PERMIT NUMBER
2, WATER SUPPLY
[] INDIVI DUAL DEPTH OF WELL
[] COMMUNITY
DATE DRILLED
[] PUBLIC UTILITY
Connection Verified_ LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER
[]INDIVIDUAL/ON -SITE DATE INSTALLED
[]PUBLIC UTILITY
Connection Verified INSTALLER
[]Septic Tank or []Holding Tank
Size: I ~-~-~ If Tank is homemade SOILS RATING
give dimensions:
TYPE OF TANK MANUFACTURER
TOTAL ABSORPTION AREA MATERIAL.~
4. DISTANCES Septic/Holding ~ranl~ Fbsorption Area Sewer Line Nearest Lot Line
/
WELL TO:
Absorption Area to nearest Lot Line
5. COMMENTS
g. APPROVEDFOR BEDROOMS
[] CONDITIONAL APPROVAL (letter must accompany certificate)
[] DISAPPROVED
DATE BY
72-010 (Rev. 6/79)