Loading...
HomeMy WebLinkAboutKNIK HEIGHTS BLK E LT 7- 0/7 '57/ MUNICIPALITY OF ANCHORAGE DEPARTMEN'r OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 LStreet- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME MAI LING ADDRESS LEGAL DESCRIPTION LOCATIOI~ _~O DISTANCE TO: / / I- ~ Manufacturer Absorption area inside la ngt b~,o~. ~"N EW [] UPGRADE .'T oJ NO. OFBEDROOMS PERMIT NO. No. of compartments Liquid deptb DISTANCE TO: /(~ ~, ' Length of each line No. of lines / .2,[~:~ / Top of tile to finish grade ./ I Length /~,A4_ Width Type of crib Dwelling Material Material benectb tile Depth ' PERMIT NO. Liquid capacity in gallons P E R MJ~T. j~_O. Distance between lines PERMIT IqO, Crib diameter Crib deptlt Total effective absorption area Well Building foundation Nearest lot line DISTANCE TO: Clas~-- Depth Driller Distance to lot line PERMIT NO, J.u . Building foundation Sewer line Septic tank Absorption area(s) DISTANCE TO: OTHER PIPE MATERIALS SOIL TEST RATING INSTALLER REMARKS 72-013 (Rev. 3/78) DATE LEGAL t~ SUlT£ '~' 101 g07-344-8042 Ill I March 4, 1985 Municipality of Anchorage Department of Health and Environmental Protection 825 "L" Street Ancharage, Alaska Reference: Knik Heights Subdivision Lot 7 Block E - Field Design Changes 8entlemen: MUNICIPALITY OF ANC;HOP, t,A~E DEPT. OF HEALTH & ENVIRONMENTAL PROTECTIOI~I MAR 6 RECEI_V_EI A permit (~ 850045) was issued for the subject property with a trench option giving a depth of 8.5'. The excavator requested that the system be as deep as possible to shorten the trench. A design change was made to give a total trench depth of 13.0' and a gravel depth of 9.0'. This changed the trench length to 25.0'. The soil rating of 150 eq.ft./BR was based on an overall averaging of the five soil layers involved between 4.0' and 13.0'. A question was raised concerning the SM soil wMch was noted on the percolation test/soil Icg. The SM soils occurred as isolated, small, discontinuous lenses and will have little influence on the overall permeability of the soil. When tile trench excavation was made it was discovered that the sandy soils indicated in the test pit were isolated to a relatively small area wht;ra the test pit was excavated. The trench wes centered over the site of the parc test and showed about 10' (horizontally) of the sandy soils. At either end of the trench, sandy gravel soils (aW-er) were exposed. The soil rating for these gravelly soils would be 125 sq.ft./BR. The system as installed is over=designed and should have a long life. Should you have any questions regarding this matter, please do not hesitate to contact us at 344- 8042. Very Truly Yours, David A. $tanlay President disk:('~RL Job'S85014 ~O_~ological Consulting ~Tesiing Laboratory * Quality Con~r~] ~ ~eptic system Design & In~ection. L. liii:E')~':q.... :!:)E:!~;(:',I::R :t: F:' :: !iiH.i)'.':~J.:) :I: '-,,; 1: !!i; :I: E)l'q ~: l.:::lx1:1: t<: FIE :!: (i!)l'[-i"::; i...(3'T' ![i',E{(:;T :[ C)N ',', 2.'? '!"Ed..'JlxlSl'l ]: F:' :: ::!f;{.'.J [::;'.¢~l'~[{':{;lii!: ',', 1 2.1",i L..CFI" S :t: ZE: '.: zl.:::;~;O0 (SC~ ,, I:::'"I' ,, Cfi:;'. (.~(::;FRI:E3) I..,:i.':il.',.cx::l b(,':.:ic)v.] <':':~i"rz¢ 't'..hc-) c:U::)'l:.ic:n"~:~; .:,:~v;,':~.J.:l.<'~;~l::~:!,(~ '1:.o you s~;ys¢.:,c:,m. Chc}(:::~::, 'N'h::.:.) C:,l:::L:i,(:~n Chad. !::~:~:~'~. f:i,t:,r:~yc::,Lu' s:;:J.'t'..,:~.::,,, "IF' IFR ~E:: [["',, Il C::: II .,,!I 4. 0 /I. ,, 0 "~. ,, 0 4 '.i:; ~ ',:..i ,::..'".' !!:.i ,/__ . :1 ........ ~J¢4 .., ........ zl.',~'~ ./ 1 ~:; 0 ¢{'¢~' Tr'>~I"JP:: ["HJS'T I'"lhVE~: f'fi" I....I::B'd~!FF Tb.JE) C;E)I¥11:::'hI::;:T'tdI~:I",I'T'~b !I GEOLAB SOl LS LOG t 131 E 76ih ~,vt: ~ ~ Il ! h nchor'egc, Alosko 344 0042 SOILS LOG-PERCOLATION TEST PEI~:CO LATION TEST WAS GROUND WATER ~ j S ENCOUNTERED7 ~ L E IF YES, AT WHAT DEPTH? 14 15 16 17 18 19 20 2248-,: Gross Net Depth to Net ~, Reading Date ,:~z Time Time Water Drop _CERTIFIED BY: COMM E N T$__~.~(~'(.}/~-'( PERFORMED ~Y: PERCOLATION RATE _~/{ ~ ~ (minutes/inch) TEST RUN BETWEEN ~ FT AND //,-- FT WATER WELL RECORD STATE OF ALASKA I)EPARTMI'_-NT OF NATURAL RESOURES Division of Geolocjicol ~ GeophysicoI Surveys , ~ . Drilling Permit No. I_OCA'IION OF WELL (Please complete either la, lb. or lc.) A.D.L. NO. I~.~j B .... gh 1 Suhdlvieion = '~- .~ ~ ' =Knch J/Knik Hr. .ct Block i/4qlr$. Section No. TownehiPN~] Range E[~ Meridian '? E i--of--of--o~ --* sE] wE] )M ROAD INTERSECTIONS 3. OWNER OF WELL: George I-I. Abbott Feet Below 4. WELL DEPTH; (final) 5. DATE OF COMPLETION su,,~o 11'?' f,. 2 - 8 -85 e Top Boliom silty 0 6 6. ~Coble ,ool ~Rolory ~ Driven ~Dug Llders 20 65 7. USE:~ OomeaHc 0 Public Supply 0 ,ndusIry Ld boulders 80 lO& O Te,JWell OOfher: LSD. S._O~.~aPd 102 117 8, CASING: ~ Threaded ~ Welded ~_pan H2C diam. 511 in. 101 15~ ~t~ Depth Weighl ~lbs./ft. diam. in. to.__ ft. Depth SlJckup~ I 9. FINISH OF WELL: Slol/Me sh Size: Length: Set between ft. and fl. Back fillin~ Gravel pack ,o. ~*~,c W,T~ L~:__ 72~ .. / / _ Dote ~ Above or ~ Below land surfoce ~1. PUMPING LEVEL below land surfoce ond Y~ELD ft. after hra. pumping~ ]~g.p.m. ft. after hrs. pumping g.p,m. 12,GROUTING Well Grouted: ~ Yo~ Materio[: ~ Neof Cement ~ Other: 13. PUMP: (if awileble) BP ....... Length of Drop Pipe ff. capacity g.p.m. 14. REMARKS: ~5. Wafer Temperature ~.o ~ F ~ C ~y jur/sdiclJon and this reporl is true to the besl of my knowledge Dad belief; ~rn' s Drilling & E~rb AA Name Conlract License Number $.~.?.?t~ Anchorage, Alaska 99516 2 WELt_ LOG Malarial Type Sand to six feet~ l~._ravelx _g ?_a~ Cj._~ h~ay_d~_, p an and 8 to 10 J~igm at 11~ 16. WATER WELL. CON!RACTOR'S Alaska No~ !14/ ..... 122,~1 Avion .~,~,,~:_ ~,~,~-~' 7~~ . ~ _ Form O2 WWR R&M Civil En#ineers ENGINEERING 8, GEOLOGICAL CONSULTANTS 229 EAST 51st. AVE. - P.O. BOX 6087 - ANCHORAGE, ALASKA 99503 TELEPHONE 907--279--0493 TELEX 090-35419 Geologists Land Surveyors JAMES W. ROONEY, P. E, MALCOLM A. MENZtES, P.E., L.S. JAMES H. WELLMAN, P.E. May 10, 1974 Mr. George Abbott P. O. Box 4-465 Anchorage, Alaska 99509 R & M No. 462024 RALPH R, MIGLIACCIO Engineering Geo)oglst Re: Test Hole and Soil Log Report for Sanitary System, Lot 7, Block E, Knik Heights Subdivision Dear Mr. Abbott: We are submitting herewith the test boring results and our comments regarding soil conditions encountered at the subject site. This investigation was performed in accordance with your request of May 7, 1974, and those procedures outlined in a letter dated September 13, 1971 by Mr. Rolf Strickland of the Greater Anchorage Area Borough Department of Environmental Quality. A single test hole was put down within the Lot 7 area for the purpose of defining general subsurface soil conditions for the proposed sani- tary system. Excavation was accomplished with a tractor-mounted backhoe and the test hole was extended to a total depth of 15.0 feet below ground surface. The final log prepared for the test hole has been included in Drawing A-01. Ground water was not encountered in the test hole. We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very truly yours, R & M ENGINEERING & GEOLOGICAL CONSULTANTS, INC. JWR:ph T.H. 1 5-8-74 ORGANICS 0.0~ 0.5' Silt, Some Sand (b~) 2.0t Gravelly Sand 0ccasional Cobble ($W-SP) 15.0' No Water Table NOTE: Test hole excavated with tractor-mounted backhoe. Engineering ~ Geological Consultants Inc. GEORGE ABBOTT PROPERTY LOG OF TEST HOLE Anchorage Alaska MUNICIPALITY OF ANCHORAGE DIVISION OF ENVIRONMENTAL HEALTH DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION APPLICATION FOR HEALTH ADTHORITY APPROVAL CERTIFICATE General Information Application Date May 9, 1985 (a) Legal Description (include lot, block, subdivision, section, township, range) Location (address or directions) Atherton Street (b) Applicants Name Custom Homes of AlaskaTel~e_phone ~ Home Applicants Addressc~.o G_~EOLAB 1131 E. 76th Ave. (c) Applicant is (check 9n__e)Lending Institution (d) Lending Institution Home Savings: Ad~Q~ ss Business 344-8042 Anchorage, Alaska 99502 e er/builder Telephone (e) Real Estate Co~ & Agent Address None Telephone (f) Mail the HAA to the following address: GEOLAB 1131 E. 76th Ave. Anchorage, Alaska ~RIS~2 2o ~y~ of Residence Single-Family~ Number of Bedrooms 3. Water ~ Individ l Well X- Other (describe) Community ~1 Public Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status° Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. [Page 1 of 2] Ensineerin~ Firm ProvJdin Ins ections. Tests. File Searcha __ . ~zn~ .... Data and Information As certified by my se. al affixed hereto and as of the validation date shown be!ow~ I verify that my investigation of this Health Authority Approval shows tt~at the on-site water supply and/or wastawater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein.. I further verify' thag~ based on ~he information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regula~ ~ions in effect on the date of this inspection. Name of Firm GEOLAB Address 1131 Eo 76th Ave. :~101, Date May 9, 1985 Telepho ne344- 8042 Approved for bedrooms CA[~ION THE, MUNICIPALITY OF ANCHORAGE DEPARTMF, Wf OF 'HEALTH AND ENVIRONMENTAL PROTECTION (DHEP) ISSUES ~/.ALTH AUTHORITY APPROVAL CERTIFICATES BASFJO SOLELY UPON THE REPRESENT- ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTE1LED IN THE STATE OF ALASKA° THE DEEP DOES THIS AS A COURTESY TO PURCHASERS OF EO~LES AND THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATUE REQULRE- MENT_So EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANA.LYZE DATA BEFORE A CERTIFICATE IS ISSUED° TEE MUNICIPALITY OF ANCHORAGE IS NOT P£SPONSIBLE FOR ERRORS OR OMISSIONS liN 'i%IE PROFESSIONAL ENGINEER'S WORK. RR4/ej/D18 [Page 2 of 2] (DHEP SEAL) 7 ~19-84 MUNICIPALITY OF ANCHORAGE (MOA) HEALTH A/7I~HORITY APPROVAL (HAA) CHECKLIST ~ FEBRUARY 1984 MUNICIPALITY OK ANCI'{OI%~[~ DEPT, OF HEALTkl & ENVIRONMENTAL PROTECTIOI~ MAY 1 0 1985 Legal Description: ~.~_~s.~_~' Subd Lot 7, Bloc]f E Sec 27 R3W T12N Well Classification Indivdual Well Log P~esent (Y/N) Yes Total Depth 117' Cased to Static Water Level 92' Casing Height Above Ground 2~' Electrical Wiring in Conduit (Y/N) Yes Separation Distances f~om Well: To Septic/Holding Tank on Lot 135' To Nearest ~k~ge of Absorption Field on Lot To Nearest Public Sewer Line NA Date Completed 115' :If A, B, c~ C, D.E.C. Approved(Y/N)NA 2/11/85 Yield 8 gpm Depth of Grouting none tkn~p Set At 115' Sanital~y Seal on Casing (Y/N)'Yes Del?~ession Around Wellhead (y/N)No Cleanout/Manhole NA To Nearest Sewer Service Line on Lot Water Sample Collected By DA Stanley ; Date 5/8/85 Water Sample Test P~sults Satisfactory Continents ; On Adjoining Lots 100'+ 149' ; On Adjoining Lots 100'+ To Nearest Public Sewer NA B o SEPTIC/HOLDING TANK DATA Date Installed 3/1/85 Size 1250 No. of Cc~,~a~tm~nts 2 Standpipes _(Y/N) Yes Air-tight Caps (Y/N) Yes Foundation Cleanout (Y/N)Yes Depression ove~ Tank (Y/N) ** Date Last Pumped NA new System Pumping/Maintenance Contract on File (.Y/N) NA ; for Holding Tank High-Water Alarm (~Y/N) NA Temporary Holding3 Tank Permit (Y/N) Separation Distance.~ fr~m Septic/Holding Tank: To Water-Supply Well 135' To P~operty Line 57' To Water Main/Servi{~ Line Course NA NA To ~ilding Foundation 25' To Disposal Field 17' To Stream, Pond, rmke, c~ Major D~ainage Con%Tents ** Slight depression ever tank. PineaL grading has not yet be~n done and ~vill correct this minor deficiency. [Page 1 of 2] Receipt Date Paid: Amount: 2-15-84 C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata _150 .s.g.ft~/.BR Type of System Design T.re~__ Date .Installed 3/1/85 Width of Field 24" Square Feet of Absorption A~ea Depression over Field (Y/N) No Length of Field 26' Depth of Field 4' Gravel Bed Thickness 9' 468 sq. ft. Standpipes Present (Y/N) Yes Date of Last Adequacy Test NA new system Results of Last Adeq~/acy Testr NA new system Separation Distance f~cm Absorption Field: To Water-Supply Well 149' To P~o~erty Line 53' To Building Foundation 47' To Existing or Abandoned System cn Lot NA ; On Adjoining Lots 100'+ To Water Main/Se~vic~ Line NA To Cutbank_( if present) NA To Stream/Pond/~ake/c~ Major D~ainage Course NA To D~iveway, Parkin? A~ea, c~ Vehicle StC~age Area 71 ' Comments D. LIFT STATION Date Installed NA Size in Gallons "Pump O!%" Level at High Water Alarm Level at Tested for Electrical Codes(Y/N) Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumging Cycles ~ing Adequacy Test. Meets MOA Comments ** (3%eck Permitted Be~rcc~ Rating Against HAA Request I certify that I have checked, verified, or C°nfol~med to all MOA HAA _G~k~d~r~s in effect On the date of this inspection.. Co a y / 2-15-84