ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP141129
PID Number: 017-372-03 ❑ New ®Upgrade
Nome:
CAMERON & MARLYS GILCHRIST
ABSORPTION FIELD
® Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
Address:
12900 BAINBRIDGE ROAD
*ANCHORAGE, AK
❑ Other
Phone:
(907) 360-9414
No. of Bedrooms:
5
Soil Rating:
0.45 cpD/sa. n.
Total Depth from original grade:
10 MAX Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade:
SEE DWG. Ft.
Gravel depth beneath pipe:
7.52/7.52 Ft.
Subdivision:
KNIK HEIGHTS
Block: Lot:
H 3
FII added above original grade:
SEE DWG. Ft.
Gravel length:
56/56 Ft.
owns ip: anger
- -
ec Ion:
-
Gravel width:
Beds Number of linea
Distance between lines:
2.5/2.5 Ft.
-
- Ft.
SEPARATION DISTANCES
Total absorption area:
1680+ SQ. Fl.
Number of trenches:
2
Disk. between trenches:
15 FL
TO
From
Septic
Tank
Absorption
Field
Lift
Station
Holding
Tank
public/Private
Sewer Lines
Well
100'+
100'+
-
-
25'+
TANK ® Septic ❑ S.T.E.P. CHolding ❑Other
Manufacturer:
Capacity:
Surface Water
100'+
100'+
-
-
ANCHORAGE TANK
1500 cal,
Lot Line
5'+
,o'+
—
—
N/A
Marial:
te
Number of comportments:
STEEL
2
Foundation
5'+
10'+
-
-
LIFT STATION
Curtain Drain
NONE KNOWN
Manufacturer. Capacity:
G.I.
Remarks:
'Pump or, level at:
"Pump off"
t., alarm at:
PER CONTRACTOR, OLD TANK WAS
DECOMMISSIONED PER UPC
Pump Make &Mode'
ctrical Inspections performed by:
PIPE MATERIAL
House to tank D3034 Tank to D3034
drainfield
Installer A+ HOME
SERVICES
Drainfield D3034 CO/MT D3034
Inspector GEG, Ltd.
BENCH MARK (Assumed elevation)
111.55 Ft.
Inspection
Dates: 1st 6/30/14
2nd 6/30/1
Location and Description:
3rd 7/1/14
4th 7/2/14
BOTTOM OF T1-11 SIDING, SW CORNER OF HOUSE
Community Development Department Approval
Conditional approval: Date:
ENGINEER'S S L
oo�o
Op
p* 4 T �0
p...... ................0�
0 .. f A. Go ness.' Q
CE- 3 �O
�4pd profeeslooc
a
Approved:
Date: 2- 2-/
I
PERMIT NUMBER: PARCEL ID NUMBER:
OSP141129 AS -BUILT . DRAWING 017-372-03
LC04
A
B
DBL1 13.61
56.13
DBL2 14.31
55.56
ST1 21.03
53.22
ST2 30.38
57.88
DBL3 32.42
58.89
DBL4 33.33
59.52
SUMP 48.80
45.60
C01 60.39
87.70
MT1 59.77
87.73
CO2 69.60
50.76
MT2 69.23
50.36
CO3 79.21
102.18
MT3 79.79
102.49
82.20
67.69
MT4 82.73
68.35
l
1\
KNIK HEIGHTS S/D; /
BLOCK H, LOT 2
EXISTING DRAINFIELD TO BE USED AS
ALTERNATE SITE (SIZED FOR 4 BEDROOMS)
i Nur CoNr+E-r-AlF-m
GREENHOUSE SUPPORTED
ON SONO TUBES AND
OVERHANGING DECK
NOTE: FLOW
SPLITTER LOCATION
E IS APPROXIMATE.
w STANDPIPE WAS
NOT INSTALLED
of
L
_ 100' WELL RADIUS a
m
EXISTING
ST2 ST1 1 HOUSE
SUMP \\� ••
04�
NEW
DRAINFIELDS NEW 1500 GALLON \ \
SEPTIC TANK \
GARNESS ENGINEERING GROUP, Ltd
CIVIL & ENVIRONMENTAL ENGINEERS
3701 E WNR ROAD. SURE 101 • ANCHORAGE M 99001 • PHONE (907) 337-6119 • FAX (907) 338-3246 • MSM ♦ 91neeN
PREPARED FOR: PHONE NUMBER: PAGE NUMBER.
CAMERON & MARLYS GILCHRIST 360-9414 2 OF 3
LEGAL DESCRIPTION: DRAWN BY:
KNIK HEIGHTS; BLOCK H, LOT 3 PNB
TYPE OF WORK: DATE:
AS -BUILT DRAWING 7/15/14
\
Irk
.��P�E.OF q!♦♦i
F
* ; '0
.............
f A. Garn ss ' 1■
Qm
CE—
12
�O.pROFESSI�� •
P
IDS P141129 AS -BUILT DRAWING
INSULATION (PER CONTRACTOR)
FINAL GRADE = 104.09-105.31
ST7 ST2
TOP OF TANK TOP OF TANK
AT INLET = 100.41 \ / AT OUTLET = 100.41
j ) NEW 1500 GALLON
INVERT OF BUNG SEPTIC TANK INVERT OF BUNG
AT INLET = 99.78 AT OUTLET = 99.62
WEST TRENCH EAST TRENCH
FINAL GRADE = 100.61-101.03
FORIGINAL GRADE 0. HIGHEST
POINT= 99.64
FINAL GRADE _
97.56-97.67 -
4" INSULATION OVER ENTIRE NF
- ORIGINAL GRADE
HIGHEST POINT = 96.81
FILTER FABRIC
OF PIPE = 94.33
— 15'
4" INSULATION OVER SOUTH
HALF OF TRENCH ONLY
FILTER FABRIC
INVERT OF PIPE = 97.16
OF TRENCH = 89.64
PARCEL ID NUMBER:
017-372-03
RELATIVE ELEVATION OF BOTTOM OF TESTHOLE = 83.64 (DRY)
BOTTOM OF TRENCH = 66.81
ELEVATION OF BOTTOM OF TESTHOLE = 80.81 (DRY)
OF
GARNESS ENGINEERING GROUP, Ltd =..,,;::,.., ,9 .......
CIVIL & ENVIRONMENTAL ENGINEERS
3701 E 1000R PMD, SURE 101 • MCHOM M M 98607 • PHOPE (B M7-6118 • FAX (607) O -3M • 1IEB n, w .Wmnwrplm n ..... . ...............i
PREPARED FOR: - PHONE NUMBER: PAGE NUMBER: 0F : f r . GO e6
CAMERON & MARLYS GILCHRIST 360-9414 3 OF 3 0 J CE -79 3
LEGAL DESCRIPTION: DRAWN BY:
KNIK HEIGHTS; BLOCK H, LOT 3 PNB ## .. FO F 41.. • r..
TYPE OF WORK: DATE: I;$;;::��
PROFILE AS -BUILT DRAWING 7/15/14
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP141129
Tax Code Number: 01737203000
Work Type: Septic Upgrade
Permit Effective Dates: May 28, 2014 to May 28, 2015
Design Engineer: GARNESS ENGINEERING GROUP LTD
Subdivision: KINK HEIGHTS
Site Legal Address: KNIK HEIGHTS BLK H LT 3 G:2836
Owner/Address: GILCHRIST CAMERON & MARLYS
PO BOX 111845 ANCHORAGE AK 995111845
Site Mailing Address: 12900 BAINBRIDGE RD, Anchorage
This permit is for the construction of:
Lot Size in Sq Ft: 43500
Total Bedrooms: 5
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Receive
Issued
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Fax: 907- 343-7997
On -Site Water & Wastewater Program
Mayor Dan Sullivan
On -Site Sewer/Well Permit Application
For A Single Family Dwelling
Parcel I.D. 017-372-03
Property owner(s) CAMERON & MARLYS GILCHRIST Day phone 360-9414
Mailing address 12900 BAINBRIDGE ROAD *ANCHORAGE, AK
Site address 12900 BAINBRIDGE ROAD *ANCHORAGE, AK
Legal description (Sub'd, Block & Lot) KNIK HEIGHTS; BLOCK H, LOT 3
Legal description (Township, Section & Range)
Lot
APPLICATION IS FOR:
( Pall that apply)
Absorption Field
Septic Tank
Holding Tank
Privy
Private Well
Water Storage
Sq. Ft. Number of Bedrooms 5
o U13MI T A
❑ MAY 2 0 2014
THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR:
TYPE OF DEWELLING:
Single Family (SF)
(w/wo ADU)
Duplex (D) ❑
Multiple Dwellings ❑
(SF and/or D)
Distance: —
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees: :?lO ' —
Date of Payment:
Receipt Number: m 15 CA V
Permit No. O` PH 11
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
(Rev. 01/11)
APPLICATION IS AN:
Initial ❑
®
Upgrade
®
Renewal ❑
❑
o U13MI T A
❑ MAY 2 0 2014
THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR:
TYPE OF DEWELLING:
Single Family (SF)
(w/wo ADU)
Duplex (D) ❑
Multiple Dwellings ❑
(SF and/or D)
Distance: —
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees: :?lO ' —
Date of Payment:
Receipt Number: m 15 CA V
Permit No. O` PH 11
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
(Rev. 01/11)
GRNESS ENGINEERING GROUP, Ltd `
��������•_>---=CIVIL& ENVIRONMENTALENGINEERS- ,U
May 6, 2014
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Proposed Septic System for Knik Heights; Block H, Lot 3;
To whom it may concern:
The existing 5 bedroom house is served by a private well and septic system. The drainfield is in
a state of failure and needs to be upgraded (sized for 4 bedrooms). We are proposing to install
a new 1500 gallon septic tank and a dual deep trench type drainfield. The old drainfield will be
left in place for use as a future reserve site. Use of this drainfield will require service by
advanced treatment or rebuilding. One testhole was excavated on the property. The new
drainfields will be designed around the 30 foot radius of this testhole. Comments regarding the
design are summarized as follows:
1. SOILS: See the attached soil log which show the soil classifications, groundwater
monitoring, and the percolation test results.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: There are no surface water concerns.
4. TOPOGRAPHY: As can be seen on the attached topograph�yy drawing, the average
topography around the proposed drainfield is approximately 15%-7.R
We are unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact us at 337-6179. Thank you for your
assistance. A
_.. M.S.
3701 East Tudor Road, Suite 101 *Anchorage. Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com
-----------------------
FAIRMONT ROAD
I I
I I
I I
I I
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
CAMERON GILCHRIST 907-360-9414 1 OF 1
LEGAL DESCRIPTION: DRAWN BY'
KNIK HEIGHTS S/D; BLOCK H, LOT 3 A.J.G.
TYPE OF WORK: DATE:
SITE PLAN FOR SEPTIC UPGRADE 3/31/2(
(Rev. 01M)
m
VAQUERO ROAD
/�----��
KNIK HEIGHTS S/D.
I KNIK HEIGHTS S/D;
--BLOCK H, LOT 16 J
LBLOCK H, LOT 1 -- ,
\\
ICONTOUR ACRES S/D
#4; BLOCK 4, LOT 3
/
00' WELL RADIUS I
i
� I
� I 00' WE.�L RADIUS_
s
I I
CSEPTIC �
I
\ /�I
AREnD
\ \ KNIK HEIGHTS S/D; I
I KNIK HEIGHTS S/D;
\ — —BLOCK H, LOT 17 J
LE LOCK H, LOT 2
00' WELL RADIUS
I
Q
/E�D KNIK HEIGHTS S/D; I
I
Of/
I.
i --BLOCK H. LOT 16 J
\
L-------- ��
i'GJ
o
Q
I
__�—�
r-------- /�'---��
RECSED �\
/
I
KNIK HEIGHTS S/D;
BLOCK
CSEPTIC
�{\ ARFE�
H, LOT 15
to
=
, I 00' RADIUS
JWELL
00' WELL RAOIUS
IKNIK HEIGHTS S/D;
-------- J
I BLOCK H, LOT 4
\L --_---
1• = loo,
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
CAMERON GILCHRIST 907-360-9414 1 OF 1
LEGAL DESCRIPTION: DRAWN BY'
KNIK HEIGHTS S/D; BLOCK H, LOT 3 A.J.G.
TYPE OF WORK: DATE:
SITE PLAN FOR SEPTIC UPGRADE 3/31/2(
(Rev. 01M)
m
NUMBER OF BEDROOMS: 5
/ GALLONS PER DAY (GPD): 750
PERCOLATION RATE/S: 34.28
PROPOSED APPLICATION RATE: 0.45
MINIMUM DRAINFIELD SO.FT.: 1667
MAXIMUM DEPTH OF EXCAVATION: 10 FEET
WIDTH: 2.5 FEET
LENGTH: 112 FEET
LETTER THAT PERTAINS TO THIS DESIGN.
TO OBTAIN A COPY OF THE LETTER
;ONTACT GEG. BY PROCEEDING FORWARD
WITH THIS INSTALLATION, THE ENGINEER,
WELL DRILLER, CONTRACTOR AND
PROPERTY OWNER AGREE THAT THEY
HAVE READ THESE SPECIFICATIONS AND
AGREE TO ACCEPT THE TERMS AND
— HEIGHTS
BLOCK — —
KNIKI2 LOT 2
EXISTING DRAINFIELD TO BE USED AS
ALTERNATE SITE (SIZED FOR 4 BEDROOMS) —1
GREENHOUSE SUPPORTED
ON SONO TUBES AND
OVERHANGING DECK
NOTE: THE CONTRACTOR
SHALL HAVE THE NORTH &
WEST LOT LINES, AND ALL
WELL RADII FLAGGED BY A
REGISTERED LAND SURVEYOR
PRIOR TO CONSTRUCTION.
\X)
\ / 1"= 40'
y�
/
/
TANK TO BE
) PER UPC.
FCO IF ONE IS NOT PRESENT
100' WELL RADIUS o
MI \ f 1
+> CO MT \� ST2 ST1 1 HOUSE EXISTING ' : ,^•: ;:
W TH#1
+ \\ \\ MT \
O CO cc
M CO
PROPOSED 1500 GALLIDIN
SEPTIC TANK \
LDOUBLE C/O'S \ \
PROPOSED FLOW SPLITTER
NOT&.
/ SYSfiEM SHALL Vt TIM T, D \
KNIK HEIGHTS 4 / a UTWg C,O,S.A APPI?OV.L \
BLOCK H, LOT 4 / A- S -
/ S f ° 1 `NT A.
GARNESS ENGINEERING GROUP, Ltd
:. .. CIVIL & ENVIRONMENTAL ENGINEERS
3M1 E. MOOR ROAM. SURE 101 a MONOWE, PI( 99507 •PHONE (W) 337-61]9 a FM (907) 336-3240 a WE95RE: 'aria.9onwaean inaarin
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
CAMERON & MARLYS GILCHRIST 360-9414 2 OF 3
LEGAL DESCRIPTION: DRAWN BY:
KNIK HEIGHTS; BLOCK H, LOT 3 PNB
DESIGN UPGRADE
14
u /9 S
•
"ROFESSO"o'
FAIRMONT ROAD
I I
I I
I I
/
/ KNIK HEIGHTS S/D . I KNIK HEIGHTS S/D; / \
/
--BLOCK H, LOT 16 J LWMIK H, LOT 1-
-- - - - - - - - -
----------I �- -J�
00' WELL RADIUS I /
I
�I00' WELL LL RADIUS
CSEPTIC \
\ I ARS \
\ \ KNIK HEIGHTS S/D; I I KNIK HEIGHTS S/D; /X — —
—BLOCK H, LOT 17 J I_BLOCK H, LOT 2
1
I ?IWOO'
SnERPTI S�D KNIK HEIGHTS S/D;BLOCK H, LOT 16J
rCSERPTTIIC
I
KNIK HEIGHTS S/D; I I [SEPTIC
BLOCK H, LOT 15 IW Y ARFE� /
00' WELL
00' WELL RADIUS --- I KNIK HEIGHTS S/D;
— J �I BLOCK H_L0T 4
---
\ / I
CALE: —
100'
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS'
I E. MOOR ROIL, SURE 101 • AN00MGE, AK 99507 • PHONE (907)]3]-8179 • FAX (907)338—UM WEB81E: wvw.9ame,ven9l,aerM9.co
;EPARED FOR: PHONE NUMBER: PAGE NUMBER:
CAMERON GILCHRIST 907-360-9414 3 OF 3
GAL DESCRIPTION: DRAWN BY:
KNIK HEIGHTS S/D; BLOCK H, LOT 3 1 A.J.G.
C OF WORK:
SITE PLAN FOR SEPTIC UPGRADE
(Rev. 01/05)
3/31/2013
VAQUERO ROAD
ICONTOUR ACRES S/D
#4; BLOCK 4, LOT 3
I
� I
I I
I I
/ I
I
I
I
z
Q
Q
GARNESS ENGINEERING GROUP, Ltd
SOIL LOG — PERCOLATION TEST
LEGAL DESCRIPTION: KNIK HEIGHTS S/D; BLOCK H, LOT 3
PERFORMED FOR: CAMERON GILCHRIST DATE: 4/$/2014
DEPTH
(feet)
ORGANICS TEST HOLE #1
t ,e:
17
18
19
SP TO SM
POORLY GRADED
SAND W/ SILT
& GRAVEL
DEPTH TO
GROUNDWATER
DATE
DRY
4/8/2014
SOIL
CLASSIFICATIONS
I
I
I
I
I TH#1+
I
I
t
`
�
�
I
I
I
I
\
1 1/8"
3 11:20
-
6"
-
a:.o:
----
-I?
r—
••,
\ I
GW
�
% SITE PLAN
ORG
3
30
:*:
7/8"
GP
ML
:`s..
:-9:
GM
CL
4
V.
GC
OL
•e:
•••
0000 o
o•oo
SW
MH
'
SP
CH
V.
SM
/
OH
6
••
SC
17
18
19
SP TO SM
POORLY GRADED
SAND W/ SILT
& GRAVEL
DEPTH TO
GROUNDWATER
DATE
DRY
4/8/2014
DRY
4/15/14
I
I
I
I
I TH#1+
I
I
t
`
�
�
I
I
I
I
ice/ I
I
II
J
I EAIC \\
I \
KNIK HEIGHTS S/D; �
LELOCK H. LOT 2
—I
I
r----------wl
I
/
�
�
I
I
I
I
I
I
I
I
I
I
I TH#1+
I
I
t
`
�
�
I
I
I
I
\
1 1/8"
3 11:20
-
6"
-
4 11:50
----
-I?
r—
7/8"
\ I
I
I CSEPTTIIC
�
% SITE PLAN
-
6 12:20
30
DATE READING CLOCK
TIME
NET TIME
(MINUTES)
WATER LEVEL
READING
NET DROP
(INCHES)
4/9/2014 1 10:50
-
6"
-
2 11:20
30
4 7/8"
1 1/8"
3 11:20
-
6"
-
4 11:50
30
5 1/8"
7/8"
5 11:50
-
6"
-
6 12:20
30
5 1/8"
7/8"
PERCOLATION RATE 34.3 (MIN./INCH)
TEST RUN BETWEEN 5.0 FT. AND
PERC. HOLE DIA. 6 (INCHES)
6.0 FT.
20 '
A FOUR HOUR PRESOAK WAS PERFORMED: E YES ❑ NO
SOILS LOGGED BY: ANDREW GRAY PERCOLATION TEST PERFORMED BY: ANDREW GRAY
COMMENTS: PERCOLATION RESULTS ARE ACCURATE TO 1/16"
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PER 0 MED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: f
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL. PROTECTION
® �1 ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 7.84-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPI-C'T'ION REPORT
NAME
UPGRADE
MAI LING ADDRESp
LEGAL DESCRIPTION d
LOCATION J/
NO. OF BED;V?MS
_ ye
DISTANCE TO:
Well Absorption area
,U a! l.tl 6 p
Dwelling
/ % /
PERMIT NO.
�� 67/7
I- Q
LU F
Manufacturer � e r l -r
�C !—�
Materia
No. of compartments
N
Liq. capacity ions
IF HOMEMADE:
Inside length
Width
Liquid depth
DISTANCE TO:
Well
Dwelling
PERMIT NO.
O Z Q
T N
Manufacturer
Material
Liquid capacity in gallons
8
LU
-
DISTANCE TO:
Well/
Foundation /
Nearest lot Iinc/ . /
PERMIT NO.
°j u z
N- z w
FTop
9
No. of lines / Length of cline
i '
of tile to finish grade
1—
Total lenth f 11 es Trench width
g--� r _ _inches
Material beneath the r/
7,o7 Pinches
Distance between
it7'.y
Total effective bsorption area
Q Q
w
Length
Width
Depth
�_
PERMIT NO.
Q F-
0.0.
LLI
Type of crib
--—
Crib diameter
Crib depth
Total effective absorption area
N
DISTANCE TO:
lNell
Building foundation
Nearest lot line
Class /�
Depth
Driller
Distance to lot line
PERMIT NO.LU
DISTANCE TO:
Building foundation
Sewer line
Septic tank
Absorption area(s)
OTHER
LEGAL
-
I
-
-
-
PIPE MATERIALS y
SOIL TEST RATING
-
INSTALLER
REMARKS
lU
I
3
APP'/( DATE
DEPHRTMENT �.
825 'L'
8���L.. 11L.- F1 PAK�>
PERMIT NO. It 810177 )
\K ~ /r`/~0/\
. �~ '`~--
HEHLTH AND ENVIRONMENTFit- ,KOT2CTION
STREET, HNCIPIORHGE, HK. 99501 ,
264~4720 ^
-~��1~��������
� �'�' � ��~ �
HPPLICHNT R&H CONST INC 4811 BISHOP WHV��^ \`\«
� ��Sx/��'`` /`
`� � �]�—l6/4
'/�l1
LOCHTION BHIN8RIDGE OFF HUFFMHN [�U[/ ''
LEGHL L] BLOCK H KNIK HTS LOT SIZE 42000
SQUHRE FEET
TYPT OF ABSORPTION SISTEM IS: TRENCH
MAIMll"! NUMBEER OF GEDROOMS = 4 SOIL RF:iTJNG
150
THE REQUIRED SIZE OF THE SOIL 19135OAPTION SYSTEM IS:
=11-1.4-- -1- C.D L~ 144 CIO W 1-1 =wm TJ N_�f"--f %0 F.H. I_. �EE-
THE LENGTH DIMENSI0N IS THE LENGTH OF THE TRENCH
OR DRHINFIELD
THE DEPTH OF H TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFHCE
OF THE
GROUND HND THE BOTTOM OF THE EXCHVHTION (IN FEET).
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRHVEL DEPTH IS THE MINIIUM DEPTH OF GRHVEL GETWEEN THE
OI.YTFHLL PIPE
HND THE BOTTOM OF THE (IN FEET).
��E L.9 1: E'.I: Un-, ����T, 1 �lt�-o 0-%-. 1: U-1 ��!.5 CE.11
����L_ V-4��
PERMIT HPPLICHNT HHS THE RESPONSI�ILlTY TO INFORM THIS DEPHRTMENT DURING THE
INSTHLLHTION INSPECTIONS OF HNY WELLS HDJHC: ENT TO THIS PROPERTY HND THE
N�M�ER OF FREE SIDENCES THAT THE WELL SERVE.
�_ -11", A I Q < �_-? ..-H J.: P-4 10 W EE Q -T 1 0 VA 05; fl EE G.7!! 0.3 1 F:�", r..,.,: 1� �--_
BACKFILLING OF HNY SYSTEM WITHOUT FINAL HND HPPROVHL BY THIS
DEPARTMENT WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTHNCE BETWEEN H WELL HND HNY ON~SITE SEWAGE DISPOSHL SYSTEM IS
100 F��T FUR R PAIYATE WELL OR 150 TO 200 FEET FR -IN H PUBLIC WELL DEPENDING
T-iiTYPE OF PUBLIC WELL
MINIMUM DISTHNCE. FROM H PRIVATE WELL TO G PRIVATE s,ENER LINE IS 25 FEET HND
T� H COMMU�ITY SEWER LINE IS 75 F:*EET.
WELL LOG_:.; AF -!E REQUlRET) AND MUST BE RETURNED TO THE DEPH?.'Tr-*IENT CIA IT'
S
Of THE WELL COMPL�TION
OTHER REQUIREMENTS MAY APPLY. HND CONSTRUCTION DIHGRHMS HIRE
RVH�LHBLE TO INSURE PROPER INSTHLLHTION
FWEAVIN x W KNUM, 1 �Q Q FE -H 1--1 ID EE ����
[ CERTIFY THAI
1: I AM FRMILIAR 141TH TFIE REQUIMMF-ENTS FOR HND WEL-S AS SET
FORTH 13Y TFIE MI NICIPFIIATY OF H�CHORHGE.
2� I WILL INSTGLL T�� SY�T�� IN HCCCIRDRNCE WITH THE CODES
]� � ��DERSTHND THHT THE ON~SITE SEWER ���TEM MAY REQUIRE ENLHRGETENT IF THE
RESIDENCE IS REMODELED TO PNCLUDE MORE THAN 4 ��DROOMS
SIGNED:~ ��~~~.... .~�~—�
HPPLICHNT R&H NC
ISSUED BY ^_--�~ Y40
:A CONSTF-`JCT10N
.�
x TEST LAB
PERFORMED FOR, R & H CONSTRUCTION
LEGAL DESCRIPTION:
THIS FORM REPORTS
18C W 48TH AVE. STE. SCI
ANCHORAGE, ALASKA 99503
248-1333
DATE PERFORMED: 4/15/81
Lot_ Block_ H Subdivision_–_Kbsi{–S3F..IGHTS —
XVisual Shcs Examination 0 Percolation Test
DEPTH SOIL
crCr nFg(-.RIPTI ON
NOTES
_
J J
✓
Overburden
Brown
r
BOTTOM OF HOLE
I
_
.0. f.
WAS GROUND WATER ENCOUNTERED_
No
v
IF YES, WHAT DEPTH'
•e °°°°'•`°"'
LEGEND
�� :•`
Q F' °• K:nney R. ter
-- Perc Zone
�Q °•• 3655 - E
�D S - Sample taken
@ F •°
Poorly Graded
Tan w/
A.;•,
Gravelly Sand
slight
150sf/br
trace of
silt
I I
I
j I�
—
Y
III
_II1
_AIN
1
W
O
J
U)
W
t -
LO
Z
w
cD
If
1
_ 1.1�-J
BOTTOM OF HOLE
I
WAS GROUND WATER ENCOUNTERED_
No
v
IF YES, WHAT DEPTH'
•e °°°°'•`°"'
LEGEND
�� :•`
Q F' °• K:nney R. ter
-- Perc Zone
�Q °•• 3655 - E
�D S - Sample taken
@ F •°
t� -- Frozen zone
If
1
_ 1.1�-J
I
-1
��
J
1--l-j-
1-
1
TIi
�
q
I
I I
I
j I�
iJ ll___I
-T_J__-
III
_II1
_AIN
1
-T
j- -j I
i I
I
I IJ J
J J
-I
{-
If
1
_ 1.1�-J
GENERAL SITE SLOPE
PERCOLATION RATE: DRAINAGE REQUIREMENTS_150sf/br
PROPOSED INSTALLATION: 0 SEEPAGE PIT JA DRAIN FIELD O OTHER
COMMENTS :------. -- --
iINAGE
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
Application Date 3 / 17 18
1. GENERAL. INFORMATION
(a) Legal Description (include lot, block, subdivision, section, township, range)
Location (address or directions)
GO 13exrn
(b) Applicant Name — n son _ Telephone: Home 3 YS -53 73 Business 269 - S-707
Applicant Address a 9Ga (jeirn br t RSC Prnehor
(c) Applicant is (check one): Lending Institution ❑ ; Owner/builder ®'; Buyer ❑ ; Other ❑ (explain);
(d) Lending Institution _
Address
(e) Real Estate Company and Agent
Address
Telephone
Telephone
(f) Mail the HAA to the following address:
---�er.0 /`(oor� F'lcc�i/aP Tec/7�rcu/ S-erycc�
-- ! ys-3 o E c� S � f}nchoo 74(.r 1-295�6 -
-
r"/t ?1V -13S' cvtion V'eac%v
2. TYPE OF RESIDENCE
Single -Family S Multi -Family ❑ Other
Number of Bedrooms
3. WATER SUPPLY
Individual Well 0 Community ❑ Public ❑
Note: It community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
Onsite 0 Public ❑ Community ❑ Holding Tank ❑
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page 1 of 2 z-nzsirvoal
ti
5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
I
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection.
Name of Firm FlctPOP 7!c64 ica/ Stet eel, _ Telephone 3 13E _
Address f -C 99,5 --id
Date - Mctrcti lG, 1986
6. DHEP APPROVAL
Approved for _o ---
Approved
1A tk
10 ... .................. .:...�
•. THEODORE F. MOOR[
a®�,•.• CE - 3589 •, �� Engineer's Seal
bedrooms by ^ �' �%P' "" Date
Disapproved
Terms of Conditional Approval
Conditional
CAUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Pane 2 of 2
A. WELL DATA
Well Classification _ Prry«Fc _ If A, B, C, D.E.C. Approved (Y/N) NtA,
Well Log Present (Y/N) N Date Completed Yield
Total Depth I rO' f Cased to '—.v 10' Depth of Grouting Af4t
Static Water Level $m' i Pump Set At Un lTnawn _
Casing Height Above Ground Sanitary Seal on Casing (Y/N) —
Electrical Wiring in Conduit (Y/N) Depression Around Wellhead (Y/N)
Separation Distances from Well:
To Septic/Holding Tank on Lot I I `I ; On Adjoining Lots 7 100'
IV
To Nearest Edge of Absorption Field on Lot (2S' _ ; On Adjoining Lots 7 (vv'
To Nearest Public Sewer Line N..4.. _ To Nearest Public Sewer
Cleanout/Manhole _ PLA — To Nearest Sewer Service Line on Lot t•i,�}.
Water Sample Collected by — Date 3 / 13 /,,(-
Water Sample Test Results — Sccits��Y — ND cmhlorrn beted-ert"at
Comments We(I S�(uw 4-"1- (�= no2uclect a /eY by r4G-_Cs
B. SEPTIC/HOLDING TANK DATA
Date Installed lBl Size Ict No. of Compartments
Standpipes (Y/N) —_— Air -tight Caps (Y/N) Foundation Cleanout (Y/N) Y
Depression over Tank (Y/N) N Date Last Pumped _ 3111( /Or
Pumping/Maintenance Contract on File (Y/N) N, A• _ ; for N. A,
Holding -rank High -Water Alarm (Y/N) .1 _ Temporary Holding Tank Permit (Y/N) lN-f1•
Separation Distances from Septic/Holding Tank:
To Water -Supply Well — If W
To Property Line
To Water Main/Service Line
Course '7 (coo
Comments
Pagel of 2
0
To Building Foundation _ to,
To Disposal Field _ s r
To Stream, Pond, Lake, or Major Drainage
MUNICIPALITY OF ANCHORAGE
_
DEPT. OF HEALTH &
MUNICIPALITY OF: ANCHORAGE (MOA)
ENVIRONMENTAL PROTECTION
HEALTH AUTHORITY APPROVAL (MAA)
MAR 17 7(JBV'
CHECKLIST - FEBRUARY 1984
264-4720
cK ' VED
Legal Description: �a-
!3�
1-c'n i k H AX .S /L
A. WELL DATA
Well Classification _ Prry«Fc _ If A, B, C, D.E.C. Approved (Y/N) NtA,
Well Log Present (Y/N) N Date Completed Yield
Total Depth I rO' f Cased to '—.v 10' Depth of Grouting Af4t
Static Water Level $m' i Pump Set At Un lTnawn _
Casing Height Above Ground Sanitary Seal on Casing (Y/N) —
Electrical Wiring in Conduit (Y/N) Depression Around Wellhead (Y/N)
Separation Distances from Well:
To Septic/Holding Tank on Lot I I `I ; On Adjoining Lots 7 100'
IV
To Nearest Edge of Absorption Field on Lot (2S' _ ; On Adjoining Lots 7 (vv'
To Nearest Public Sewer Line N..4.. _ To Nearest Public Sewer
Cleanout/Manhole _ PLA — To Nearest Sewer Service Line on Lot t•i,�}.
Water Sample Collected by — Date 3 / 13 /,,(-
Water Sample Test Results — Sccits��Y — ND cmhlorrn beted-ert"at
Comments We(I S�(uw 4-"1- (�= no2uclect a /eY by r4G-_Cs
B. SEPTIC/HOLDING TANK DATA
Date Installed lBl Size Ict No. of Compartments
Standpipes (Y/N) —_— Air -tight Caps (Y/N) Foundation Cleanout (Y/N) Y
Depression over Tank (Y/N) N Date Last Pumped _ 3111( /Or
Pumping/Maintenance Contract on File (Y/N) N, A• _ ; for N. A,
Holding -rank High -Water Alarm (Y/N) .1 _ Temporary Holding Tank Permit (Y/N) lN-f1•
Separation Distances from Septic/Holding Tank:
To Water -Supply Well — If W
To Property Line
To Water Main/Service Line
Course '7 (coo
Comments
Pagel of 2
0
To Building Foundation _ to,
To Disposal Field _ s r
To Stream, Pond, Lake, or Major Drainage
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata fsa j0' //3c(rn Type of System Design 7—ren c h
Date Installed .5'/ r5- / &
Length of Field 53
Width of Field 3 " Y,
Depth of Field `f `
MOA No. SSS —O,C
Gravel Bed Thickness 6
Square Feet of Absorption Area 63(5'
Standpipes Present (Y/N) Y
Depression over Field (Y/N) N
Date of Last Adequacy Test 7
Results of Last Adequacy Test Su ks fn c /or
c�Cr oomr
°+• e• 6 s
f�'••+�°�'���
• +'.� Engineer's Seal
Separation Distance from Absorption Field:
Amount: $
To Water -Supply Well f 2,S1
To Property Line
To Building Foundation > 3 0 `
To Existing or Abandoned System on
Lot N,&
; On Adjoining Lots 7' 3 G `
To Water Main/Service Line
To Cutbank (if present) 1111 F%•
To Stream/Pond/Lake/or Major Drainage Course
7 Cv0
THEODORE F. MOORE :•
® . -
•, CE - 3589o�
To Driveway, Parking Area, or Vehicle Storage Area
Comments Aucccx {-csf eer �o r -m tGC 7/20 l6
72-026 (11/84)
D. LIFT STATION N• A.
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
Comments
Dimensions
Manhole/Access(Y/N)
— "Pump Off' Level at
Vent(Y/N)
Pumping Cycles during Adequacy Test. Meets MOA
" Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection
Signed
Date Mcurcy /6, /986
Company
Tech S `c r
MOA No. SSS —O,C
Receipt No. �5
7��
���� At 44
Date of Payment
j�
°+• e• 6 s
f�'••+�°�'���
• +'.� Engineer's Seal
F t3�':
Amount: $
���
+ �t�TFi �`��®�
yy�
°s
Page 2 of 2+®fit
THEODORE F. MOORE :•
® . -
•, CE - 3589o�
+
"ProfmiO
72-026 (11/84)
�4
t VAVAlk 0
MUNICIPALITY OF ANCHORAGE
DIVISION OF ENVIRONMENTAI. HEALTH
DEPARTMENT OF H1=TH AND ENVIRONMENTAL PROTECTION
APPLICATION FOR HEALTH AU'T'HORITY APPROVAL CERTIFICATI: 44
1. General Information Application Date
(a) Ligal,Desjjiptioln,(include lot, block, subdivision, section, ltownship, range)
n (.-}ddress, or directions)
(b) Applicants Name
Applicants Address
�-1ele hone •- Home Business
(c) Applicant is (check one) Tending Insp*,i.tution ; Owner/builder
Buyer , Other (explain);
(d) Lending Institution
Address
(e) Real Estate Co. & Agent
Address
Telephone
(f) Mail. the HAA to the following address:
2. Type of Residence
Single -Family Multi -Family
Number of Bedrooms
Tel�!Etione
MUNICIPALITY OF ANCHORAt3E
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
'AUG 71084
RECEI\(ED
Other (describe) q ��
3. HatrZ ly
Individual Well,11 � Communi.Community� Public
.,.<'._
Note: If community well system, must have written confirmation from the State
Department. of Envirorunental Conservation atteuting to the legality and status.
4. Sewage Disposal
Onsite Public Community � Holding 'Dank E—A
Note: If community well system, murs`b have written confirmation from the State
Department of Environmental Conservation att:estl.ng to the legality and status.
[Page T of: 21
5.ineering Firm Providing InsElctions,_Tests1_Fiille Search, Data and Information
As certified by my seal affixed hereto and as of the validation date shown below, I
verify that my investigation of this Health Authority Approval shows that the on-site
water supply and/or wastewater disposal system is safe, functional and adequate for
the number of bedrooms and type of structure indicated herein. I further verify that,
based on the information obtained from the Municipality of Anchorage: files and from my
investigation and inspection, the on-site water supply and/or wastewater disposal
system is in compliance with all Municipal and State codes, ordinances, and regula-
tions in effect on the date of this inspection.
Name of Firm
Address
Date
6. DEEP Approval
E o o'
It
(ENGINEER SEAL)
Approved for _ bedrooms By
Approved. - Disapproved
Terms of Conditional Approval
CAU'T'ION
SUO.LI_ Telephone_,5(C,/--
(C/--
Conditional (�
THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
(DEEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT-
ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAI' ENGINEER REGISTERZD
IN THE STATE OF ALASKA. THE DIIEP DOES THIS AS A COURTESY TO PURCHASERS OF (-TOMES AND
THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CURTAIN FEDERAL AND STATE REQUIRE-
MENTS. EMPLOYEES OF DEEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A
CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONST.BI FOR ERRORS
OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK.
(DEEP SEAL)
RR4/ej/Dl8
[Page 2 of 2 ] 7-19--84
��
a tl
INK 4P"Ilk
^� tf�aS��' � 'f Vii.
U � .4��•
g
000P9^449dq ii4B£OB 61BB9c!: r,J2.s J:J �I
pJ B94(
29j1 e 1,10
Conditional (�
THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
(DEEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT-
ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAI' ENGINEER REGISTERZD
IN THE STATE OF ALASKA. THE DIIEP DOES THIS AS A COURTESY TO PURCHASERS OF (-TOMES AND
THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CURTAIN FEDERAL AND STATE REQUIRE-
MENTS. EMPLOYEES OF DEEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A
CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONST.BI FOR ERRORS
OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK.
(DEEP SEAL)
RR4/ej/Dl8
[Page 2 of 2 ] 7-19--84
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
A. WELL EATA Legal Description: P'oLk
Well Classification If A, B. or C, D"".��E.C. Approved(Y/N) IvIt,
Well Log Present (Y/ Date Completed Yield 5.D�
Total Depth 150 a- Cased to �6_ �OG1 Depth of Grouting �D 1 o!�
V_ _—"-
Static �—
Water Level ���� Pump Set At�V-
Casing Height Above GroundSanitary Seal on Casing OI)
Electrical Wiring in Conduit N) Depression Around Wellhead (YAM
Separation Distances from Wall:
To Septic/Holding Tank on Lot �� o On Adjoining Lots
To Nearest Edge of Absorption Field on?Lot Of On Adjoining Lots
To Nearest Public Sewer Lie M JA To Nearest Public Sewer
Cleanout/Manhole----b A To Nearest Sewer Service Line on Lot ,N
Water Sample Collected By 1WJEjM f:1C ; Date
Water Sample Te t Results
Canments e_o_SSuP ed leo n1
B. SEPTIC/HOLDING TANK DATA
Date Installed J i5 Size _ t 25U No. of Ccxnpartments 2
Standpipes (ON) Air -tight Caps ON) Fundation Cleanout (ON)
Depression over Tank (Y/I@ Date Last P1 d �
Pumping/Maintenance Contract on File (Y ) A ; for lid
1 114
Holding Tank High -Water Alarm (Y ) Temporary Holding Tank Permit (Y/N)/VI ,+
Separation Distances from Septic/Holding Tank:
To Water -Supply TAbll 00.4-
O — To Building Foundation
To Property Line D] To Disposal Field J
To Water Main/Service Lire �� To Stream, Pond, Lake, or Major Drainage
1n
Course
Comment
[Page 1 of 21
2 -is -a4
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata \S d Type of System sign-Ck.eo('��
Date Installed ' 81 Length of Field _-53
Width of Field i _ Depth of Field
Gravel Bed Thickness �0
Square Feet of Absorption Area 4 00 ® Standpipes Present ) _�
Depression over Field .(ON) Date of Last Adequacy Test '77 2,C) 8
Results of Last Adequacy 'lest 6 - c --6v,(
Separation Distance from Absorption Field:
To Water -Supply Well O d} 6) To Property Line _ 2.�+
To Buildin Foundation 2A,
To Existing or Abandoned System on
Lot (� On Adjoining Lots 20
t I
To Water Main/Service Line To Cutbank(if present)
To Stream/Pond/Lake/or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area�'U,+_
Cormtients 0 nAEQs ( W- F-1) � o_cr�rl �` O�7j i� S SAS . cwt I lel s 1
D. LIFT STATION
1`
Date Installed Dimensions _
Size in Gallons _ �- nh le/Acce
"Pump On" Level at "Pump Of t -t
High Water Alarm level at Ve
Tested for Pumping Cycles r
Electrical Codes(YM)
Convents
at
Adequacy Test.
Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verified, or, conformed to all. MOA PAA Guidelines in effect
on the date of this inspection.
Signed �XiZU�� •�liYtny/2, Date r '�(� /(T"� ��Q°��`.�F •�:;�� to
Company C L a MOA No. l�baA& S e' o�P
Q
KB1 /d5/s
[Page 2 of 21
e)-
-/07
)--/G`%
2-15-84
ALASKA b dROf1 PTAL COWROL SNOIC65, IX
Cngineerinq & Cnuironmenlal Studies
AUGUST 6 1984
BRUCE BEADELL
4105 TURNAGAIN BLVD
ANCHORAGE AK 99503
SELLER — .TEFF ROSS BUYER — PHILLIP HANSON
SUBDIVISION — KNIK HEIGHTS BLOCK — H LOT — 3
ADEQUACY TEST FOR SEWER SYSTEM
THE TYPE OF ABSORPTION SYSTEM IS A TRENCH WITH AN AREA OF 600 SOFT.
THE SYSTEM IS CAPABLE OF ACCEPTING 720 GALLONS OF WATER PER DAY.
THE SURGE CAPACITY OF THE SYSTEM IS 600 GALLONS.
BASED UPON THE, TEST DATA THE SYSTEM IS ACCEPTABLE FOR A
4 BEDROOM HOME,
THE SEPTIC TANK WAS PUMPED ON 7/27/84
FLOW TEST ON WELL
THE WELL FLOC' RATE WAS 4.6 GPM MR 2 HOURS.
SEPTIC TANK ADEQUACY
THE EXISTING SEPTIC TANK VOLUME OF 1250 IS ADEQUATE FOR
THIS 4 BEDROOM HOUSE.
lsl4'* ;
SON6D.(QYj�"9 �90au00aa003qu .:�:., '��i
♦� 9� k � N v
I �!p��}�it��aicB boc�enrno o f
l01 S18�C�A�Ci. A oCoo x.16% °u C.S;t
A� 10% Lei.C. Reid, Jr.
'o
Y
F r,,
1200 UJesl 33rd Auenue. guile B • AnAorage. Alasko 995039'907) 561-5040
5. LEGAL DESCRIPTION --
STREET LOCATION -
i _ L o A
6. TYPE OF RESIDENCE NUMBER OF,B D MS
( SINGLE FAMILY 0 One �0 Four ❑ Other
❑ Two ❑ Five
❑ MULTIPLE FAMILY ❑ Three E7 Six
7. WATER SUPPLY —
�] INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled
❑ COMMUNITY since June 1975. For wells drilled prior to that date, give well
❑ PUBLIC UTILITY depth (attach log if available.)
B. SEWAGE DISPOSAL SYSTEM --
INDIVIDUAL/ON-SITE** __YEAR ON-SITE SYSTEM WAS INSTALLED.
❑ PUBLIC UTILITY
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
-- —ter -----�
72-010 (Rev. 6/79)
—�e
DATE RECEIVED
INSPECTION APPOINTMENTS
TIME
TIME
TIME
DATE
DATE -
DATE-
p
l
INSPECTOR
INSPECTOR -
INSPECTOH
MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE
/
.DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION DEPI. OF HEALW & -
825 L Street - Anchorage, Alaska 99501 PICIfECTION
ENVIRONMENTAL
ENVIRONMENTAL SANITATION DIVISION � L� 791
Telephone 264-4720
��yy
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEW fik)Ccb WsD
DIRECTIONS: Complete all
parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing.
1. PROPERTYOWNER
1 11 PHONF
1C)v\ Y) C a lj Fj� Li
MAILING ADDRESS
-
tSdf
PROPERTY RESIDENT (If different from bove)— I HONE
2. BUYER
—
PHONE
MAILING ADDRESS
3. LENDING INSTITUTION
PHONE
MAILING ADDRESS
—
4. REALTOR/AGENT
— -- PHONE
A�Qb-6��,C_7)
MAI LING ADDRESS
5. LEGAL DESCRIPTION --
STREET LOCATION -
i _ L o A
6. TYPE OF RESIDENCE NUMBER OF,B D MS
( SINGLE FAMILY 0 One �0 Four ❑ Other
❑ Two ❑ Five
❑ MULTIPLE FAMILY ❑ Three E7 Six
7. WATER SUPPLY —
�] INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled
❑ COMMUNITY since June 1975. For wells drilled prior to that date, give well
❑ PUBLIC UTILITY depth (attach log if available.)
B. SEWAGE DISPOSAL SYSTEM --
INDIVIDUAL/ON-SITE** __YEAR ON-SITE SYSTEM WAS INSTALLED.
❑ PUBLIC UTILITY
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
-- —ter -----�
72-010 (Rev. 6/79)
THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE
❑ SINGLE FAMILY
❑ MULTIPLE FAMILY
NUMBER OF BEDROOMS
❑ ONE ❑ THREE ❑ FIVE ❑ OTHER
❑ TWO ❑ FOUR ❑ SIX
2. WATER SUPPLY
Cl INDIVIDUAL
❑ COMMUNITY
❑ PUBLIC UTILITY
Connection Verified
PERMIT NUMBER
DEPTH OF WELL
DATE DRILLED
LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM
❑INDIVIDUAL/ON -SITE
❑PUBLIC UTILITY
Connection Verified
PERMIT NUMBER
DATE INSTALLED
INSTALLER
❑Septic Tank or ❑ Holding Tank
Size: If Tank is homemade
give dimensions:
SOILS RATING
TYPE OF TANK
MANUFACTURER
TOTAL ABSORPTION AREA
MATERIAL
4. DISTANCES
WELL T0:
Septic/Holding Tank
Absorption Area
Sewer Line
Nearest Lot Line
Absorption Area to nearest Lot Line
5. COMMENTS
9�1—' APPROVED FOR cy BEDROOMS
❑ CONDITIONAL APPROVAL (letter must accompany certificate)
❑ DISAPPROVED
DATE �1
BYE