Loading...
HomeMy WebLinkAboutWEST ADDITION KNIK HEIGHTS BLK 2 LT 8West Addition Knik H ight lock 2 Lot 8 017-371 -28 Inspection Report _1-1-12.doc Municipality of Anchorage=� , c, •�11-1� 0V Community Development Department Page 1 of 4 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP171222 PID Number: 017-371-28 ❑ New ❑✓ Upgrade Name: Richard & Carolyn Melms ABSORPTION FIELD ❑✓ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 4201 Leyden Rd ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 1.0 GPD/SF 11 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 5 Ft. Gravel depth beneath pipe 6 Ft. Subdivision Block Lot Knik Heights West Addition 2 8 Fill added above original grade 0-2.5 Ft. Gravel length 50 Ft. Township Range Section Gravel width 2.5 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Spptic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 600 Z Ft N/A N/A Ft. well 100+ 100+ N/A N/A N/A TANK p Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1,250Gal. Surface Water 100+ 100+ N/A N/A Material of compartments Lot Line 10+ 10+ N/A N/A Ste]—Number 2 NA Foundation 5+ 10+ N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain 50+ 50+ N/A N/A Gal. Remarks Pump on level at in. Pump off level at in. High water alarm at in. Pump make and model Electrical Inspections performed by Installer PIPE MATERIAL House to tank 303Tank to 3034 4 drainfield A+ Home Services Drainfield 3034 CO/MT 3034 Inspector Pannone Engineering Services BENCHMARK (Assumed elevation) 100ft Inspeection ction 15� 8/21/2017 2nd 8/21 /2017 Location and description 3`d 8/29/2017 4`h Door Threshold COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp �F A�'QSIa�� Conditional Approval: Date ,l�G *: TH • F�onnope .teven C 8149 r pp o ed Date a 0 i 17 ik, ggpp�1A ;-0- Inspection Report _1-1-12.doc NOTES: 1.) FIELD WAS CONSTRUCTED IN FLAT AREA WERE THE SAME AT BOTH ENDS OF FIELD. \ AA\ EXISTING GRADE ELEVATIONS 2.) DEPTH OF FIELD MODIFIED DUE TO GROUND WATER. SEE DESIGN PARAMETERS. WELL (E) SWING TIES �, � (� / A B T1 48.40 43.80 -::Cgg_ 112.90 C:2 �99. 2 0 /00 /0, 1 "6' \' DRAIN FIELD (E) IN FAILURE f\ -RE -USE AS RESERVE LLI W-1 LLJ 1 I<t F - LOT 8 BR I\ HOUSE _0 (E) o TH-1 M1 C1 FC E) 0 M 2 1250g SEPTIC TANK C2 DECOMMISSIONED PER CODE DV T1 WELL (E) DC 104.9���j NEW UPGRADED DRAIN FIELD T2 50LF x 2.5'W x 6.0'ED x 1 1.0'TD INSTALLED MT AND CO AT EACH END 5' UTILITY EASEMENT - PLAYHOUSE 4– (NO FOUNDATION) 7� NEW 1250g SEPTIC TANK LEYDEN ROAD Z/- NO NOTES: Nk Date PAMONE ENG SVC, LLC N, 11/27/2017 RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 Scale DRAWN BY: ow 49 T!i * -.* � 1"=50' NJC ...... P.I.D. NO KNIK HEIGHTS WEST ADDITION, BLOCK 2, LOT 8 ..... .. ......... 017-371-28 t�Ste��v�enR. �P�o�nn�6ojmee RICHARD & CAROLYN MELIVIS PERMIT NO. CE 8149 4201 LEYDEN ROAD Sheet OSP1 71222 PLAN ANCHORAGE, AK 99516 2 OF 4 DESIGN PARAMETERS TEST HOLE UPGRADE SEPTIC SYSTEM PROPOSED NO. BEDROOM: 4 (600 gpd) EXISTING TANK SIZE: 1,250g LEGEND PERC RATE: <1MPI W- WATER LINE/ SOIL RATING: 1.0 GPD/SF WELL RADIUS AREA ROD: 600 SIF PERMIT NO. OSP1 71222 SYS. TYPE: DEEP TRENCH: 8.0'ED SS - NEW SEPTIC MIN LENGTH: 37.5 LF USED: —GB— GRADE BREAK TOTAL AREA: 600 SF ------ (��- RETAINING WALL NOTES: PAMONE ENG SVC, LLC RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 DRAWN BY: NJC EL, 97.2--" FILTER FABRIC 4" 0 DRAIN PIPE EL. 93.5 DRAIN ROCK 6" ABOVE PIPE INV EL929 11 GALTANK L, 92.2 2.2 _F7E DRAIN ROCK i EL. 86.2--_ 86.2 SP/ _—EL sw 50.0 PROFILE BOH DESIGN PARAMETERS TEST HOLE UPGRADE SEPTIC SYSTEM PROPOSED NO. BEDROOM: 4 (600 gpd) EXISTING TANK SIZE: 1,250g LEGEND PERC RATE: <1MPI W- WATER LINE/ SOIL RATING: 1.0 GPD/SF WELL RADIUS AREA ROD: 600 SIF PERMIT NO. OSP1 71222 SYS. TYPE: DEEP TRENCH: 8.0'ED SS - NEW SEPTIC MIN LENGTH: 37.5 LF USED: —GB— GRADE BREAK TOTAL AREA: 600 SF ------ (��- RETAINING WALL NOTES: PAMONE ENG SVC, LLC RECORD DRAWING P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 DRAWN BY: NJC KNIK HEIGHTS WEST ADDITION, BLOCK 2, LOT 8 4201 LEYDEN ROAD SECTION ANCHORAGE, AK 99516 8/21/eon | TH TEST HOLE (P) PROPOSED (E) EXISTING CO CLEAN OUT NO. MT MONITOR TUBE NO "— § ' 15�* *61��*, Steven R. nnome - Date Scale 49 Ri NTS "— § ' 15�* *61��*, Steven R. nnome - CE 8149 PERMIT NO. OSP1 71222 Sheet MUNICIPALITY OF ANCHORAGE men r On-Site Water& Wastewater Program ti° ate_ PO Box 196650 4700 Elmore Road G �. Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http://www.muni.org/onsite Ili' I) partimcnt .4�ry CN OR RGE On-Site Wastewater Disposal System Permit Permit Number: OSP171222 Effective Date: 8/17/2017 Work Type: Septic Upgrade Expiration Date: 8/17/2018 Tax Code Number: 01737128000 Site Legal Address: WEST ADDITION KNIK HEIGHTS BLK 2 LT 8 G:2836 Site Mailing Address: 4201 LEYDEN RD, Anchorage Owner: MELMS RICHARD G & Lot Size in Sq Ft: 48981 Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 4 This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Ublj) Date: Issued By: kliteiell . I, Date: 417 D MUNICIPALITY OF ANCHORAGE N)Community Development Department � �� Phone. '$7-343=7904 Development Services Division F. 7-34 -799 On-Site Water & Wastewater Program + -t- ON-SITE SEWER/WELL PERMIT APPLICATION a AUG 1 U 2017 lti• I ti Parcel I.D. 017-371-28 c><< 0>" Richard & Carolyn Melms 01 s a Property owner(s) y Day phone Mailing address 4201 Leyden Road, Anchorage, AK 99516 Site address 4201 Leyden Road Legal description (Sub'd., Block & Lot) West Addition Knik Heights, Block 2, Lot 8 Legal description (Township, Range & Section) Lot Size 48,981 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ❑X Upgrade 111Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. Signature of property owner or authorized agent) Permit/Rush Fees: 51,9 Waiver Fees: Date of Payment: VIM?' Date of Payment: Receipt Number: aags36 Receipt Number: Permit No. 05/9/9/VN9d� Waiver No. Permit App_ . • .: .,c Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail:steve@panengak.com August 9, 2017 Subject: Knik Heights West Addition, Block 2, Lot 8 Upgrade Septic System Permit Request Design Narrative This is a design narrative for a permit to install an upgrade septic system to be issued for this property. The proposed system will serve an existing four (4) bedroom house. The existing drain field is in failure and will be re-used as a reserve. The system will utilize a replacement 1250g septic tank and conventional drain field. This lot and the surrounding lots are served by private wells. There are no wells within 100' of the proposed septic system. 1. Soils. One test hole was performed in the vicinity of this system by PES in August 2017, and groundwater was monitored for at least seven days. Ground water was not observed to a depth of 19' below the surface in the test hole monitor tube in August of 2017. Bedrock was not encountered in the test hole to 19'. Based on the results of the percolation tests and overall soils appearance; an application rate of 1.0 gallons/day/square was used for a conventional wastewater system in the area of the test hole. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The existing topography on the lot generally slopes from east to west, with a slope of approximately 5% in the area of the drain field. There are no steep slopes in the vicinity of this system. The proposed drain field will maintain 50' separation all steep slopes. 5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On-Site Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 I \ . — . — . — . 1. !2 / ' .1''' DRAIN FIELD (E) I (LURE RE—USE AS RESERVE w�— W--f NN I • N LOT 8 --- M� --n-, V''l w 48 R "a HOUSE `ii 1N o O,p • (E) ' o TH-1 9� I o • I • 160 011,Q :_ I WELL (E)—\ UPGRADE DRAIN FIELD (P) I 101.5 I 4OLF x 2.5'W x 8.0'ED x 13.0'TD INSTALL MT AND CO AT EACH END 5' UTILITY EASEMENT • PLAYHOUSE 1250g SEPTIC TANK (E) (NO FOUNDATION) DECOMMISSION PER CODE AND INSTALL 1250g SEPTIC TANK (P) DOUBLE CLEAN OUT, AND DIVERTER VALVE ya' LEYDEN ROAD \ ( � w ,N% I1Ni‘ �M�NI _\ ,`n. DESIGN PARAMETERS UPGRADE SEPTIC SYSTEM NO. BEDROOM: 4 (600 gpd) LEGEND TANK SIZE: 1,250g W WATER LINE/ PERC RATE: <1MPI WELL RADIUS ABBREVIATIONS SOIL RATING: 1.0 GPD/SF AREA ROD: 600 SF TH TEST HOLE SS NEW SEPTIC SYS. TYPE: DEEP TRENCH: 8.0'ED (P) PROPOSED MIN LENGTH: 37.5 LF (E) EXISTING — — —GB— — — GRADE BREAK CO CLEAN OUT NO. U� n RETAINING WALL MT MONITOR TUBE NO. 4OLFx2.5'Wx8.O' E.D., 13.0' TD TYP TYPICAL TOTAL AREA: 640 SF NOTES: ���7���\� Dote PANNONE ENG SVC, LLC - OF At 1k 8/17/2017 FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 r't� ..''...AS k� PHONE (907) 272-8218 FAX (907) 272-8211 "two): �i�''�y#� Scale DRAWN BY: "*: • ,�\\� 1"=50' DRM •"' .S�' P.I.D. NO KNIK HEIGHTS WEST ADDITION, BLOCK 2, LOT 8 / i—� � .... . - 1-28 RICHARD & CAROLYN MELMS 0 Steven 'I;"-onnorae PERMIT NO. 6 �.'. CE 8149 4".17 •J/� OSP171222 4201 LEYDEN ROAD 146)4:• • • PLAN ANCHORAGE, AK 99516 t��t •o�Fssio�p\,,= Sheet 3 NNN. - 1 OF SOILS LOG - PERCOLATION TEST TEST HOLE 1I l SLOPE �I SITE PLAN `^ ` OR ORGANICS ` / 1 4BR HOUSE 2 O� (E) I 3 ` TH-1 \\� JL4,.. 4 5 6 \ TH 1 IklINI IA:111:- A' 7 I 8 9 \— • --- . . 5 I - SP/SW SAND 10 PLAYHOUSE (NO FOUNDATION) \ 11 12 I FYI-1EN RC7Af1 N 13 WAS GROUND WATER SLOPE 14 ENCOUNTERED? N 15 IF YES,AT WHAT TH DEPTH? -DRY x 16 17 DEPTH TO WATER AFTER MONITORING? -DRY 18 DATE: 8/10/17 WATER 19 BOH READING DATE CLOCK NET TIME LEVEL NET DROP READING 20 1 8/3/17 8:15 --- --- --- 2 DATE PERFORMED:8/3/17 3 _WATER DROPS TOO FAST 4 TO ACCURATELY READ 5 6 PEROLATION RATE <1 (min/inch)PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 5 FT AND 6 FT 'SEE SIEVE ANALYSIS COMMENTS:Test hole excavated by A+ HOME SERVICES PERFORMED BY: Dan Moran. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDI INFS IN FFFFCT ON THF DATE OF THIS TEST. FOR CONSTRUCTIONNO NOTES: PANNONE ENG SVC, LLC =— OF A��S'lll 8/17/201/ P.O. BOX 102954 ANCHORAGE, AK 99510 �,tp, Scale PHONE (907) 272-8218 FAX (907) 272-8211 �c�-- �� • y r DRAWN BY: *: ,,+ I. \ *1040 NTS DRM --:41 `� ffitP . 0 P.I.D. NO KNIK HEIGHTS WEST ADDITION, BLOCK 2, LOT ; r • • • . / 017-371-28 RICHARD & CAROLYN MELMS O'•�teven . �'onnorae f PERMIT NO r p.•• CE 8149 .•4,� OSP171222 4201 LEYDEN ROAD +t$46?-r, . r SOILS LOG ANCHORAGE, AK 99516 p4 0py� -= Sheet `��\\\��.� 2 OF 3 040.002 Crowther Associates Client: Pannone Engineering Services Projects: West Addition Kink Heights Subdivision Block 2 Lot 8 Date: August 10, 2017 Particle Size Distribution Table Sample Source Block 2 Lot 8 Sieve Size 3 inch - - 1-1/2 inch - - 3/e inch - - #4 100 #10 99 #40 96 #100 16 #200 10 0.02 mm - - Classification Sand with Silt (SP-SM) 1632 Bellevue Circle/Anchorage,Alaska 99515 Telephone(90 7)349-2198/E mail: crowther@alaska.net SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55. 2. SCOPE OF WORK: REPLACE SEPTIC TANK. INSTALL NEW DRAIN FIELD. 3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 19 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 19 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. 4. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK. 5. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED. 6. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES. 7. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE ENGINEER. 8. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN. 9. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED-LINE AS-BUILT DRAWINGS TO THE ENGINEER. THE RED-LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND TANK ELEVATIONS. 10. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN-OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING. 11. THE CONTRACTOR PROVIDED DATA (UPON WHICH THIS RECORD DRAWING IS BASED) APPEARS TO REPRESENT THE PROJECT AS CONSTRUCTED. THIS DATA IN CONJUNCTION WITH THE PERIODIC FIELD OBSERVATIONS BY THE ENGINEER (OR HIS DESIGNEE) AS REQUIRED BY AMC 15.65 DOES NOT GUARANTEE THAT THERE ARE NO HIDDEN DEFECTS BY THE CONTRACTOR. 12. THE CONTRACTOR SHALL SIGN THE FOLLOWING; I CERTIFY THAT ALL WORK WAS PERFORMED IN ACCORDANCE WITH THE APPEND PERMIT, AND ANY AND ALL CHANGE ORDERS, AND THAT THE AS-BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED. CONTRACTOR: BY: . TITLE: DATE; . NOTES: ��� ��\ Dote PANNONE ENG SVC, LLC pF A�q l FOR CONSTRUCTION kk4 8/17/2017 P.O. BOX 100217 ANCHORAGE, AK 99510 p�• S� Scale PHONE (907) 272-8218 FAX (907) 272-8211 rg • �1 •7v + DRAWN BY: 5*: .9TH \ *`, NTS DRM '•• INIP •• �� • P.I.D. NO KNIK HEIGHTS WEST ADDITION, BLOCK 2, LOT ; • ' 017-371-28 RICHARD & CAROLYN MELMS t= n ''. •onn, e t PERMIT NO. 4201 LEYDEN ROAD ��'^� CE 8149 . ice OSP171222 DESIGN DETAILS ANCHORAGE, AK 99516 +!4`9``0FESS`= 'r Sheet 3 Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Mark Begich Anchorage, AK 99507 Mayor Ww ,Mni.ora/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: SW Date of Issue: Parcel Identscation Number: Legal Description Property Owner NameCO &F Address: 1/l/F�T A�7D /T/ON ua` lAL y� N rev Al l K /Y %—S AvlchoR'gir / )JK y9ss6 11 Pump Installation Date: Pump Intake Depth Below Top of Well Casing: feet Pump Manufacturer's Name: Ay me DonAC? Pump Model: 9IX 75-✓ 3LQ Pump Size VIC/ hp Pitless Adapter Burial Depth: 10 feet Pitless Adapter Manufacturer's Name: Pitless Adapter Installer: r Well Disinfected Upon Completion? Yes ❑ No Method of Disinfection: Ci.0e0y ,PG t t4T5 Comments: Pump Installer Name: AnChOseAgf. tvyl(0\� 19clvn10SE,?vrC19 Attention: The pump installer shall provide a pump installatitn log to the DSD within 30 days of pump installation. MI]N!C]PAI,ITY OF ANCHORAGE ~ a~)d Environmental ProEec Fourbh };'[l<)or West 825 L Street Ant:hot age ~ Alaska 99501 27g-:-25]1, x 224, 225 7t ~ iNSPECTION litEI~Of::T ON.-SlT: -SEWAGE .... 7~..: '" : :7-:::LT::L- 72:7 7' :~ ~ :'. L ' .. L : SEPTIC TANK: 'I'O1AL 21 i':(TIVF BUll_DIN(,, ['OUNDA'I ON ...... NFARLh'I t.Of I IiWL ...... AIRSORI'TION ARIA (WALl_ ARFA) .......... S(~. ~ ~ r ..... , .... ;' ,"-. -. 'r' '-~--,:--: :'-.':::':-{-"::"':-"': .' ..... ,~-. ...... - ............... b ' ' ~ ~ ' ~ ' , ' :-~~ Well Dos~ance '~'o~ LoC %inn I~)~ ~ , ' ' I~ ' ~ Pipe ~ata::~.~:o~_?~-: ..... .;.. : .... ,, ~~ . : ~'~ : ' l--, I-Ail 6 7 l)e' rtment of Health and Environment"l Protection ~chorage, Alaska 99507 Ibis form reports: Soi]s ]og._~ ............. Percolation test l)e p t h Feet 1:1,- Was ground water encountered? Percolation rolo mlnu De¢(ii---t'O"bB'Ct-oln"}/r-'l>i L or trenci, ..... j'i t)~pLh of Inlet .................... · FAII{BANKS CONSULTANTS, INc. JUNI;4U 249 EAST 51ST AVENUE P.O. BOX 6087 ANCHORAGE, ALASKA 99503 TELEPHONE 907-279-0483 TELEX 090-35419 August 25, 1975 R & M No. 562082 Mr. Joe Drimmer Ocean Technology, Ltd. 2502 West Northern Lights Blvd. Anchorage, Alaska 99503 Test Hole and Soil Log Report for Sanitary System Lots 1 and 5, Block 1; Lots 1, 4, 5 and 8 Block 2 West Addition, Knik Heights Subdivision Dear Mr. Drimmer: In accord with your instructions of August 18, 1975, four test borings were drilled and logged at the designated locations in the West Addition, Knik Heights Subdivision. Approximate test hole locations are shown on the attached Location Diagram A-01. Ail the test borings were advanced to a depth of 20.0 feet below ground surface. The drilling was initiated on August 19, 1975, and completed on August 21, 1975. A total of four test holes were drilled for the purpose of defining general subsurface soil conditions. Excavation was accomplished with a track mounted "CME 55" rotary type drilling unit. As illustrated by the accompanying logs, the general soil profile consists of a 6 to 8 inch layer of organics overlying 6 to 12 inches of sandy silt. This in turn is underlain to depth of investigation, predominantly by alter- nating layers of gravelly sand and sandy gravel with varying amounts of silt. The exception to this is Test Hole'#5 where an eight foot layer of silt was found from 6 to 14 feet deep. A water table was found at a depth of 10.5 feet in Test Hole #7. We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very truly yours, R & M CONSULTANTS, INC. JWR/PJ/ja Leyden Road Fairmont Road Consultants inc. ANCHORAGE FAIRBANKS ALASKA JUNF-AU OCEAN TECHNOLCGY LTD. LOCATION D I AG P~AM AIqCI{ORAGE, ALASK~A 8-8-75 ISCALE 1"=200 'II DWN BY~ I CWKD BT ?,_]F I PROJ. NO, 50208--~ '~ rowG F/o A-o]. R OATE TH-4 8-19-75 0.0' ORGANICS (peat) ~-- 0.5' SANDY SILT ORGANICS ()fL) 1.5' S.'bYDY GPc~VEL s/SOME SILT OCCASIONAL COBBLE (GM) 4.0' SANDY GRAVEL TRACE SILT (OW) 7.0' GRAVELLY SA.MD w/SOME SILT (S~O 9.0' SANDY GRAVEL w/TRACE SILT (GW) 14.0' GRAVELLY SAND TRACE SILT (SP) NO WATER TABLE 20.0' T.D. Log represents See location diagram A-01 Consultants Inc. ANCHORAGE FAIRBANKS ALASKA JUNEAU 8-25-75 !sc~ 1"=3' TH-5 8-19-75 0.0' ORGANICS 0.5' SANDY SILT w/SOME (ML) 1.0' SILTY .... ~D w/SOME GRAP~L (s~,[) 4.5y SAND w/SOHE GP~\VEL AND SILT (SM) 6.0' SANDY SILT (~m) 8.5' SILT w/SOME SAND AND TRACE GRAVEL (~m) ........... 14.0' GRAVELLY SAND w/TRACE SILT (S~) 18.0' SILTY SAND w/SOME GRAVEL (SD[) 20.0' T.D, NO WATER TABLE OCEAN TECHNOLOGY, LTD. Log of Test Holes Anchorage, Alaska WED 1P~oJ. No. 562082 lows ~o. A-02 8-21-75 0.0' ORGANICS - --0.5' SANDY SILT w/S~ ORGANICS 1.5' S_~:q) w/TFL,\CE CIb\VEL (S?) 3.0' SAJ~FDY GRAVEL w/TRACE SILT (OW) 5.5' GRAVELLY SAND w/TRACE SILT (SP) 6.5' SAND w/SOME GRAVEL A~) TRACE SILT (SW) 10.5' .... 14.0' G[~VELLY S~fD w/TRACE SILT (SP) x .... 15.0' SAND w/SOME GRAVEL (SW) NO WATER TABLE 20.0' T.D. 2'II- 7 8-21-75 0.0' .0' SILT w/'iTIACE CLAY (am) 4.0' SANDY G}~AVEL w/SOSfl~ TO TF~C E SILT (GM) 8.0' GRAVELLY SAND w/SOME TO TRACE SILT (SM-SP) (200 sq.ft. x per bedroom) ~-- 9.5' SAND w/SO~X~ SILT 7uND GRAVEL (wet) (SM) 13.5' SANDY GFo\VEI, w/SO.HE SILT OCCASIONAL COBBLE (Gbl) 15.5' GRAVELLY SAND w/SO},fE TO TRACE SILT (SM) 20.0' Log represents See location diagram A-01 Consultants lnc, OCEA2~ TECHNOLOGY, LTD. Log of Test Holes Anchorage, Alaska