Loading...
HomeMy WebLinkAboutKNIK VIEW BLK 1 LT 6Knl*k View Block 1 Lot 6 #051-031-29 Inspection Repoli 9-1-12.do' Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 Page d of ff ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP131211 PID Number: 051-031-29 Dwelling: X Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New Upgrade Name: Gary & Susan Larsen ABSORPTION FIELD Dee ❑ p Trench El Shallow Trench El Bed El Mound Address 22509 Inlet Vista Drive, Chugiak, AK ❑ other Phone Number of Bedrooms Soil Rating Total depth from original grade (907) 750-8203 4 0.8 GPD%SF 10.47 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4.47 Ft. Gravel depth beneath pipe 6 Ft. Subdivision Block Lot Knik View 1 6 Fill added above original grade Varies 0.5-1 Ft. Gravel length 65 Ft. Township Range Section Gravel width 2.5 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 780 Fel 1 N/A Ft. Well * * NA NA 25+' TANK J9Septic E:1 STEJHolding E]Otherrr k fgTj ' Manufacturer Anchorage Tank Capacity 1250 Gal. Surface water100+' 100+' NA ''. NA Material Number of compartments Lot Line 10+' **6' NA '; NA Steel 2 NA Foundation 5+' 10' NA NA LIFT STATION Manufacturer Capacity Curtain Drain None NA NA NA Gal. Remarks *Subdivision is on public water. Pump on level at Pump off lev High water alarm at in. **Requesting a waiver of 6' from leach field to west lot line. yyyin. Pudel mp mn ake a o Electrical Inspections performed by to MATERIAL House to tank D3034 Tank ld D3034 PIPE MMdrainfe Installer Dean Construction Drainfield F81 Operf CO/MT Inspector F. Kenley BENCH MARK (Assumed elevation) 100 ft Inspdates: 1" 7/22/13 7/23/13 Location -and description aro 2., 4tn N.E. Corner of house @ Point A. See Pg. 3 COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL En �eyf r�stamp �} Conditional Approval: Date �h 41�2�d� OCG iY Y. Approved ( rt/ L f '' Date - . / 2 t 2i 1 4 Inspection Repoli 9-1-12.do' / Lot 5 SEPTIC SYSTEM 0 / TH#® / a col / T Co I C / o(-) A II m -0 H5 3111 / New 65'X6'E.D.2.5'widey/MT2 / TH#4®WCO2 / Lot 7 DOUGLAS T. KENLEY, P.E. Ciml Engineer ME.NmtleYrai • (99117161%3 1°`"' Gary Larsen View S/D, Block 1, Lot 6 09 Inlet Vista Drive, Chugiak, AK %D °u°BF'°-050-721-28 /13 1cx.K" DTK I a—w FK I ` 1 = 30, 1 are NUYBE1: 13116 OF. Atgst� 00 * ' 49 TH ,tl .. ASBUILT �� Dou sT. enley F CE -81]6 _•���_ PExurt XUUB :OSI,131211 �PR SBS10 ''' SHEET 2 of 4 � LEACH FIELD PROFILE FILL ADDED ELE VARIES 101' TO 101.5 100.05' ORIGINAL GRADE ® T.H.-3 FROM EXISTING RUN DIVERSION VALVE 6' E.D. X 65' LONG TRENCH. BOT.=89.45' BOT.=89.58' BOT.=89.59' BOT.=89.58' GROUND WATER EL' @ 7/22/13 NONE BOTTOM OF TEST HOLE #5 81.95' NOTES: REFERENCE POINT WAS 4.87' LOCATED @ TOP OF FOUNDATION BLOCK SHOWN ON DESIGN P. 2 OR 3 MARKED A. SWING TIES A B C01 19.8' 54.0' MTI 18.6' 52.4' DIV. VALV. 17.5' 49.5' CO3 17.0' 48.7' TEE 29.0' 26.0' MT2 47.0' 18.5' CO2 56.3' 22.0' NOTES:TEE WAS LOCATED AT THE MID -POINT OF 32.5' FROM THE END OF THE 65' LONG TRENCH. DOUGLAS T. KENLEY, P.E. ME.Nq Wr Cln* . Pa[m ,Al W • (Wi)lJ goo `"'n Gary Larsen U`''° Knik View S/D, Block 1, Lot 6 J°BBBR22509 Inlet Vista Drive, Chugiak, AK . 7/24/13 CHfgtEOi DTK "" FK CMI Engineer PROFILE ""°B`"051-031-29 °E ""B"BEA; OSP 131211 NTS JOB "H"BEB: 13116 SHEET 3 OF 4 P• • i *� 49 TH*�) i / Do glas T. Kenley AIW ROFES���'+�a``r \��\ Municipality of Anchorage °` Nr j' P.O. Box 196650 • 4700 Elmore Road Anchorage Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 _ Department Development Services Division On -Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: osp131228 COSA#: osc131362 Permit#: osP131211 PID#:051-031-29 Legal Description: Knik View B-1 L-6 Engineer: Doug Kenley Applicant: Gary and Susan Larsen Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 6.0 feet. This waiver approval applies to the existing absorption field only. Any future upgrade to the on- site wastewater disposal system will require all separation distances be met or another approval from this department. ® The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ❑ Adjacent properties are not affected by this waiver. .............................................................. a . . . . . . . . . . . . . . . . Waiver is Granted: X Waiver is not Granted: Date: *� f� Approved lo: Na wer ............................................ ... .. ...................... Rec#: 005625 Amount: $200.00 Date Paid: 7125113 **** VARIANCEIWAIVER REVIEW **** Douglas T. Kenley, P. E. 9806 E. Northstar Circle, Palmer, Alaska 99645 (907) 746-1073 July 25, 2013 Municipality of Anchorage On -Site Services 4700 South Bragaw Anchorage, Alaska Re: Gary Larsen Knik View S/D, Block 1, Lot 6 22509 Inlet Vista Drive Chugiak, Alaska REQUEST FOR WAIVER OF LEACH FIELD TO LOT LINE AND CONDITIONAL COSA A Narrative was filed at the MOA dated July 19, 2013, at which time Permit #OSP131211 was issued to upgrade the failed septic system. After construction and receipt of the land surveyor's plat, it was discovered that the leach field was 6' from the west lot line of the above property. Therefore, we are requesting a waiver from leach field to lot line. We are also requesting a Conditional COSA to monitor the water level in test hole #5, which monitoring will end on July 30, 2013. During construction, it was discovered that the outlet of the tank was lower than the pert pipe. Test hole #5 was dug on July 23, 2013, to establish a 6' separation from bed rock and to remain 5' from ground water. If you have any questions, please call me at (907) 746-1073 or 243-5372. Sincerely, U Douglas T. Kenley, .E. PE #8176 ELE 100.05' Organics GW SP W/SOME LARGE ROCKS SP W SOME LARGE R CKS GP SOILS LOG — PERCOLATION TEST TEST HOLE #5 m a,: ,° w 3- 3-0� �. _a �p 3 ML GM CL Lc OL ;p u„°$•..e,. a SW MH H.. �S::j5:.ya'sc CH SM / OH Sc DEPTH TO GROUNDWATER DATE N/A 7/23/13 7/30/13 G S -1-i.3 7/23/2013 4.87' REF — 100.00'. -e-c DATE READING TIME NET TIME WATER LEVEL NET DROP (MIN.) READING (IN.) (IN.) S. Of H. PERCOLATION RATE (MIN./INCH) PERC. HOLE DIA. (IN.) ELE. 81.95' TEST RUN BETWEEN FT. AND FT. PRESOAKED FOR FOUR HOURS YES NO COMMENTS: HOLE WAS USED TO CONFIRM SEPERATION FROM BED ROCK & GROUND WATER. IT WILL ALSO BE USED FOR 7—DAY MONITORING, PERFORMED BY: FRED W. KENLEY I, DOUGLAS T. KENLEY, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DOUGLAS T. KENLEY, P.E. Civil Engineer 9 E.NMHUAN. PoImx,Nrke98&5 (BOn f,a-ton 111T: Gary Larsen Knik View S/D, Block 1, Lot 6 .nox<ss 22509 Inlet Vista Drive, Chugiak, AK " wTc 7/24/13 c..' DTK I w"_ FK •'F. NTS LOG 1-031-29 -OSP 131211 13116 SHEET 4 OF 4 OF At`klk�+ P• - low * .49 THklll/ �.. / D u s . Kenley / l�hF���r CE -8176 ��q 'w�;1`\\\ FEsS \k = On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP131211 Tax Code Number: 05103129000 Work Type: Septic Permit Effective Dates: July 19, 2013 to July 19, 2014 Design Engineer: DOUGLAS T KENLEY Subdivision: KNIKVIEW Site Legal Address: KNIK VIEW BLK 1 LT 6G:1557 7- 2 z- i, -,j ) f Owner/Address: LARSEN GARY WILLIAM & SUSAN JEAN 2832 DARLING AVE FAIRBANKS AK 997095842 Site Mailing Address: 22509 INLET VISTA DR, Chugiak Lot Size in Sq Ft: 20276 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field N Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: Construction may proceed at your own risk before the 7 day water monitoring is complete. Please submit stamped and signed results with the As -built Inspection Report. 7/21�/3 reid GhGng1e C)Jec /77 C4 Q o A ""1", Received B) Issued By: -?I &Ocecq of yiqu( , .,r 65 �e�f _o7e l8' te,thole- owl,7 /ISIS �r7 AA/ �YroWna ovafe� rHon�for��q MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program s ON-SITE SEWER/WELL PERMIT APPLICATION r Parcel 1. D. 051-031-29 RUSH! y� Property owner(s) Gary and Susan Larsen J Day phone 1 (907) 0 Mailing address 2832 Darling Avenue, Fairbanks, AK 99709 Site address 22509 Inlet Vista Drive, Chugiak, AK Legal description (Sub'd., Block & Lot) Knik View S/D, Block 1, Lot 6 Legal description (Township, Range & Section) Lot Size 20,473.2 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ElUpgrade 0 Duplex (D) ❑ Holding Tank ElRenewal ElMultiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. or authorized agent) Permit/Rush Fees: 530 sill Waiver Fees: Date of Payment: 111013 Date of Payment: Receipt Number: O2s_I:6 Receipt Number: Permit No. 051'131a-» Waiver No. Permit App_"-:. :'-:c. Douglas T. Kenley, P.E. 9806 E. Northstar Circle, Palmer, Alaska 99645 (907) 746-1073 July 19, 2013 Mr. Doug Larsen. Owner Inlet View S/D, Block 1, Lot 6 22509 Inlet Vista Drive Chugiak, Alaska PERCOLATION TEST RESULTS AND GENERAL SITE INVESTIGATION REPORT On July 9, 2013, an adequacy test was attempted. The water elevation within the leach field was measured at 1-1/2" from the bottom of the distribution pipe. After the introduction of 86 gallons of water into the system, water could no longer be heard running in the clean-out. Checking the monitoring tube showed that water had risen 3" above the invert of the distribution pipe. Flow was cut back to a trickle and let run to see if it would drop down at all. The water was turned off and the level was checked again two hours later and the water depth was measured at 38-3/4" from the bottom of the monitoriung tube, representing a Y4" drop over the two-hour period. The water depth was again checked on July 10`x' and was found to be 38-1/2" from the bottom of the monitoriung tube. A total of 139 gallons had been introduced during the test. Based on these readings, the system was considered to be in a failed condition. To facilitate the permitting and installation of a replacement leach field, a test hole was performed on July 17, 2013. The test hole was dug to a depth of 16.7' and a monitor tube was installed. No ground water was observed during the excavation of the hole. It is proposed that the replacement system be installed in the area designated on the original design documents. A percolation test was performed which showed that the soils percolated at a rate of approximately 12 minutes per inch. It is proposed that a 3' wide, 7' E.D., 60' long trench be installed as the replacement system. The proposed design is sufficient to serve a four-bedroom house on the above -referenced 0.47 acre property. The Knik View S/D is served with public water. The lot slopes approximately 0-1% in the area of the proposed leach field. The parcel is treed with spruce, birch, and alder, with birch being predominate. On-site observation and physical survey show that there is a private wastewater disposal system within 100' of the proposed system. It appears that there is no potential for contamination of adjacent water wells or streams. Mr. Gary Larsen. Owner July 19, 2013 Page 2 The proposed system will have no measurable impact on reserve space, surface or subsurface, or on drainage to adjacent lots. Please consider this report as a request for review and approval of the attached design drawings for a replacement on-site wastewater disposal system. We have verbally requested permission from the On -Site Services Department to proceed with construction of the replacement trench without waiting to check the water level in the monitor tube after 7 days. If there should be any questions concerning the percolation rate or characteristics of the site, please call me at (907) 746-1073 or 243-5372. Sincerely, Douglas T. Kenley, P.E. PE#8176 SEPTIC SYSTEM SPECIFICATIONS: 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE M.O.A. WASTEWATER CODE CHAPTER 15.65.060- 2. EXISTING 1250 GALLON TANK TO BE LEFT IN PLACE. 3. SERVICE LINE TO DRAIN FIELD SHALL BE 4" DIA. ABS PIPE. 4. DRAIN FIELD LINE SHALL BE 4" DIA. 3034 ASTM PIPE WITH HOLES LAID DOWN 5. NEW LEACH FIELD TO BE PLACED IN ALTERNATE SITE WEST OF EXISTING FIELD NTH A DIVERSION SPLITTER & 14' SEPARATION BETWEEN TRENCHES. 6. PROVIDE 10' MINIMUM SEPARATION BETWEEN EDGE OF TRENCH AND FOUNDATION. 7. PROVIDE 10' MINIMUM SEPARATION BETWEEN SEPTIC SYSTEM AND PROPERTY LINE. 8. PROVIDE 200' MINIMUM SEPARATION BETWEEN SEPTIC SYSTEM & PUPLIC WELLS, 100' PRIVATE WELLS & SURFACE WATER. 9. FOR APPLICABLE EXCAVATION, TRENCHING, AND SHORING SAFETY STANDARDS, CONTACT THE STATE OF ALASKA, DEPARTMENT OF LABOR, OCCUPATIONAL SAFETY AND HEALTH COMPLIANCE CONSULTATION, AND TRAINING DIVISION OF LABOR STANDARDS AND SAFETY AT 269-4955. 10.PROVIDE INSULATION OVER DRAIN FIELD IF ANY AREA IS FOUND TO HAVE LESS THAN 3' OF COVER. BOTTOM OF DRAIN FIELD IS NOT TO BE PLACED LOWER THAN EL. 94.75'. BASIS OF ELEVATION IS A RIDGE ON TOP OF FOUNDATION BLOCK LOCATED 0 POINT A ON SITE PLAN P. 2 OF 6. DRAINFIELD CALCULATION FOR TRENCH SOIL TYPE: POORLY GRADED SANDS WITH ROCKS & BOULDERS (SP) PERCOLATION RATE: 12 MINUTES PER INCH APPLICATION RATE (AR): 0.8 GAL./DAY/SF DESIGN (4) BEDROOMS: DISCHARGE = 4 BEDROOMS X 150 GALLONS/DAY = 600 GALLONS ABSORPTION AREA = 600 GALS PER DAY/0.8 GALS PER DAY/SF = 750 SF EFFECTIVE DEPTH = 7' TRENCH LENGTH = 750 SF/(2X7') = 53.6'. USE 60.0' • ASSUMES DOMESTIC WATER USAGE FOR RESIDENTIAL HOME CONSUMPTION. • CALCULATION METHOD OBTAINED FROM MUNICIPALITY OF ANCHORAGE "WASTEWATER DISPOSAL CODE REGULATION" FEBRUARY 14, 2003; AMC 15.65, TYPICAL DEEP TRENCH FIELD REQUIREMENTS AND SPECIFICATIONS. DOUGLAS T. KENLEY, P.E. Engineer "`'""'1q ME.XaM•IaC . M .,u 11I a . ,M„,�M, CALCULATIONS 'U°"Gary Larsen F0.Yi Knik View S/D, Block 1, Lot 6 �22509 Inlet Vista Drive, Chugiak, AK rre 7/19/13 1M. DTK °R' FK 1-031-29 '""': 13116 SHEET 1 OF 6 c� OF.A�'gs1j11 49 TH Do as T. Kenley j 160x,, . CE -817 'SAW ++,11,'�PROFESS� ��� tt8 tat 9 Loc 10 Lot 11 ALDER LEAF COURT 244.3__ I l I DOUGLAS T. KENLEYB P.E. CIA Engineer DESIGN MOB EXp9MxCIrtY. PNnwAIW NFS (W'/j]WOTd p1nn. Gary Larsen 22509 Inlet Vista Drive, Chugiak, K /19/13 `""`" DTK °"°"` FK AB"" 1" = 100' 13116 SHEET 2 OF 6 OF•AC'q �1 49 TH *I Doug T. Kenley I PF% CF -817f �```�i ('I�1F� ROFESSVONP��� �Aater S Lrvice (SYSTEM pprox. oc. 168.68' .168.68' No slope >25% w/in 100' of septic. n 30.7 S w & ° o—/ 0A� / Cj) / idence 6 T.H.-4 36 9 4' \ DOUGLAS T. KENLEY, P.E. a,„I Enginrer DESIGN MENwtl 'Cr . . (pp7pT i 1d w., -Gary Larsen .Knik View S D, Block 1, Lot 6 '122509 Inlet Vista Drive, Chugiak, AK p01"110 050-721-28 7/19/13 `”""� DTK 0" FK 1" = 20' J00 X0NBfA` 13116 SHEET 3 of 6 /l i New 60'; OF A`1l *: 49 TH -�Do sTPenley �Fc/ E-8 76 • • �� i LEACH FIELD SECTION - PROPOSED FILL ADDED ELE. 100.55 100.05' ORIGINAL GRADE ® T.H.-3 2" INSULATION IF NEEDED— BULL RUN DIVERSION VALVE FLOW SPUTTER ENTERS ® MID -POINT 97-05' 96.57OFPIPE TOP OF GRAVEL INVE7' E.. LONG TRENCH. 89.55' --/NONE BOTTOM OF TRENCH GROUND WATER EL' ®7/18/13 BOTTOM OF TEST HOLE 83.35' NOTES: REFERENCE POINT WAS 4.87' LOCATED 0 TOP OF FOUNDATION BLOCK SHOWN ON DESIGN P. 2 OR 3 MARKED A DOUGLAS T. KENLEY, P.E. am BExwnw.n,u...wn...tr..u6 . WFIT» m %1HBGary Larsen ' Knik View S/D, Block 1, Lot 6 i0 22509 Inlet Vista Drive, Chugink, AK "'x'7/19/13 1 °NF DTK °"""" FK xue ITEM LEGEND 1 Bull Run DIV. VALV. 2 FLOW SPLITTER 3 CO -1 4 MT -1 5 CO -2 6 MT -2 EXIST. 1,250 GAL.TANK (TO REMAIN) Civil Engineer NTS —031 PROFILE 13116 (SHEET 4 OF 6 Aw A.1�E OF q(,gslll�) CO 49 TH ...;.�. ,,�.I.' n / Ga' ... '. Dou las . Kenle �� j "pROFESSIOq� ELE 100.05' hganics W P V/SOME LARGE CKS P V SOME LARGE CKS ig B. of H. ELE. 83.35' SOILS LOG — PERCOLATION TEST DEPTH TO GROUNDWATER DATE NONE 7/11/13 NONE 7/18/13 7/17/13 1 7/17/2013 4.87' REF = 100.00'. See attached site plan & Page 4 of 5 on leach field elevations GATE READING TIME NET TIME (MIN.) WATER LEVEL READING (IN.) NET DROP (IN.) 7/17/13 1 3:45 PM ---- 8 ---- 4:15 PM 30 5-12/16 2-4/16 2 4:16 PM — — — — 8 ---- 4:46 PM 30 5-6/16 2-10/16 3 4:50 PM — — — — 8 ---- 5:20 PM 30 5-8/16 2-8/16 4 5:22 PM — — — — 8 ---- 5:52 PM 30 5-8/16 2-8/16 PERCOLATION RATE 12 (MIN./INCH) PERC. HOLE DIA. 6 (IN.) TEST RUN BETWEEN 7 FT. AND 7-1 2 FT. PRESOAKED FOR FOUR HOURS YES7 N0 PERFORMED BY: FRED W. KENLEY I, DOUGLAS T. KENLEY, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. OF qtqs��++ AWS.• I 49 TH .* ... DOUGLAS T. KENLEY, P.E. Ergine., SOILS woaexwttxarnrt • v.�.,,,r+usww loor)nsnon LOG �� •Doug T. Kenley 'Gary Larsen CE -8116 ••�� a. Knik View S/D, Block 1, Lot 6 �� �llt• '�( (":6 •13' ��\� s 22509 Inlet Vista Drive, Chugiak, AK 051-031 —29 °FPY""`�"°` I�;F�PROfESS10NP-� °"" 7/19/13 1 tl1 : DTK I °P: FK I � NTS '1pB MUYB°` 13116 SHEET ELE 100.05' SOILS LOG — PERCOLATION TEST Organics TEST HOLE #4 GW .0 GW 1110 ,. IIIIIIIIII Isc "NNNNSID W�SOME LARGE ��� R CKS SP W SOME LARGE R CKS GP B. of H. ELE. 83.35' DEPTH TO GROUNDWATER DATE N/A 7/17/13 7/17/2013 4.87' REF = 100.00'. DATE READING TIME NET TIME WATER LEVEL NET DROP (MIN.) READING (IN.) (IN.) PERCOLATION RATE (MIN./INCH) PERC. HOLE DIA._ (IN.) 191 TEST RUN BETWEEN_ FT. AND FT. 20 PRESOAKED FOR FOUR HOURS YES NO 'OMMENTS: HOLE WAS USED TO CONFIRM SOIL CONDITIONS. IT WAS NOT NEEDED FOR OTHER COVERED ENOUGH OF TRENCH. AS T.H. PERFORMED BY: FRED W. KENLEY I, DOUGLAS T. KENLEY, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DOUGLAS T. KENLEY, P.E. CIA Engineer me.Nd mm • PMr,YrMYB919 • mn?mon 'Gory Larsen Knik View S/D, Block 1, Lot 6 ..22509 Inlet Vista Drive, Chugiak, AK PO" mfr: 7/19/13 IFDTK °ROec FK I — NTS LOG —031-29 13116 SHEET 6 OF 6 yAlN P�E OF A <qsl�+l *: 49 TH *� tJ.. Douglas .�,enl�e�y-' '++,1\ F PR F S1S10�+'�i 0f,_. r17 _1G , n Municipality of Anchorage Page _ 1 of a DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 e Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number:SW`950�39 PIDNumber: I O?�la a — Name: Wastewater System: 0 New ❑ Upgrade Address: lr1p P-�IAQ�SJILL.� WA 4aa�n I I ABSORPTION FIELD Phone: No. of Bedrooms: ❑Deep Trench ,W Shallow Trench ❑Bed ❑Mound ❑Other LEGAL DESCRIPTION Soil Rating: I Total Depth from original grade: 8 r -2_ GPD/So. Ft. Lot: Block: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe l4 I Kw I K -E' '31 Ft. ?� r Ft. Township: — Range: — Section: Fill added above original grade: Gravel length: 67-5 /1 Ft. 5p � Ft. WELL: u El New El Upgrade Gravel width: P Number of lines: Distance between lines: FXISTI �Ft. Ft. Classification (Private, A,B,C): n Total Depth: Cased To: otal absorption area: Pipe material: Aso'WN CCASC J /a FL Ft. �7 Op S0. Ft. f�S$UP303 1- Driller: Date Dril Static Water Level: Installer 500THFO¢14 L/lotJ51 Date installed: II- II- q5 Ft. Yield:ump Set at: Casing Height Above Ground: TANK GPM Ft. Ft. SEPARATION DISTANCES ;ZSeptic ❑ Holding ❑ S.T.E.P. To Septic Absorption Lift Holding Public/Private Manufacturer: Capacity in gallons: From Tank Field Station Tank Sewer Lines AuCHOo_AdI�-% MtWe- /a 50 Well aova- aovfi _� ?S -r Material: S"I'EE-L- Number of Compartments: �- Surfac 14- 1 Uvh _ — LIFT STATION Watere 100 _ Lot i t Size in gallons: Manufacturer: Line IC) d (D d– — — — Foundation I w a i "Pump on" level at: "Pump otf� Il at water alarm at: Curtain Pump Make�ej ecfrical Inspections performed by: Drain Remarks: 1 v ESLD^fit, BENCH MARK and Description: 11 1 1Location N77 H.4 fYT"GnQ-- 5 MJF tZ�L 1L 7 t -r—' /� IGS Or- f;o"DAT(O o`r 6) No� �C7`i1 NEP— A Assumed Elevation: 1400 S & !i ENGINEERING� 7... W .. .....:....... Inspections performed 4 a4 eagle River Loop Road, No.2a'Dates: 1st I (-la -9s ;� ,� Eagle River, Alaska 99577 j1 ,^f �` 2nd 11 � 11 � 45 J R0 ERT C. COWAN t801 p �, Department of Heal -and uman Services approval ' Reviewed and approved by: Dater 72-013 (Rev. 9/91) MOA 25 Permit No. SW950239 Page 2 —of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Pin N� . LOT 6, BLOCK 1, KNIK VIEW SURD. 05103129 Legal Description: _ 72-013 A (Rev. 9/91) MOA 25 PINA GRADE MT1 C05 99.91 100.9' R NEW 94.!"X12.60 GAL �� 7' 93.8' SEPTIC TANK 90.8' cl 3 q NO (?4o.CocGc .2 G., wAr4/2 SEPTIC RESERVE AREA— N A B — - FCO 8' NEV 1250 GAL ST1 11 51' r,4 I I C01 1 4 50' sr2 ) I I I CO2 15' 50' sn ° ° co! CO2 I I j ATHQ2 CO3 37' 56' co I CO3 I C04 50' 80' 0 � I IAI i C0545' 41' YE IVE 0 IIT"K'I TT MT1 44' 3-8- 8 _ C) C) � I I I Y W Y I I �L �lATt COS LOT 6NEW TH TRENt P ..........` 7sFQ@ A " '• .ryQ n nsyJps / e.o•/euJq/rY// P� § ROBERT C. COWAN i a a Gj i'. ci: • 8601 SCALL: 1" = 72-013 A (Rev. 9/91) MOA 25 (ENCAl ti-o5AAL) ,s ��� A, 1, Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST` t .,�'v�- tLr1 ✓ zr— r' –^ ItoeIPT C. COINAN "� z CE - 6601 7 f PERFORMED FOR: I�� V J(5�1/�1I G— DATE LEGAL DESCRIPTION:_l�U"i- �P hJv�1L I Y—rl t IL Township, Range, Section: - - •- 14 zl) 10 11 12 13 14 15 16 17 18 19 \ F�til SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? S IF YES, AT WHAT L 0 DEPTH? p E Depth to Waler er Monitoring? Date: 17i3a i _ Reacting Date Gross Net Depth to Net Time Time Water Drop 20 I PERCOLATION RATE (minutesimch) PERC HOLE DIAMETER �J TEST RUN BETWEEN FT AND I _ FT COMMENTS 4V J (t—(L(3fzA)K'° C t{— J PERFORMED BY: S & S ENGINEERING _ Iy/�t/ „kp, �� CERTIFY THAT THIS TEST WAS PERFORMED IN 17034 F.aglo River Loop Road No. 204—`�`�� ACCORDANCE WITH e6bfbTKAIWIAWip�IkUIf ,t -,GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-66.50 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW950239 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:SCHMELZER FAMILY TRUST OWNER ADDRESS:P.O. BOX 799 MARYSVILLE, WASHINGTON 98270 PARCEL ID:05103129 LEGAL DESCRIPTION: KNIK VIEW BLK 1 LT 6 LOT SIZE: 20276 (SQ. FT.) NUMBER OF BEDROOMS: 2 THIS PERMIT: ( THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: PAGE 1 OF 1 3Psr DATE ISSUED: 8/23/95 EXPIRATION DATE: 8/23/96 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED ISSUED BY DATE: DATE: -23 0�7 �'2- F i��- I-/1/G/N�FF�R G/l�q,���p uPbrr�P��a 7`a Foul Rr�Ao/laatic� S & S1 ROBERT C.COWAN, RE, alneeRInG - ROBERTA. SHAFER, P.E. EAGLE August 28, 1995 �zn CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 41'r, C",�B HEALTHAUTHORITY Municipality of Anchorage V APPROVALS DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 L Street U n%U,;;:, , J9,9' - ox 6650 SEWER&WATER Anchorage, 9Alaska 99519-6650 epi y�'a/th4 NQ11) 9e MAIN EXTENSIONS V%Coo REFERENCE: Lot 6 Block 1 Knik View Subdivision SEWER&WATER INSPECTION Dear Mr. Daniel J. Roth, A permit (SW950239) was issued on the referenced property on AND REPOORTSRTS Y g ENGINESTUDIES 8_23-95. This is to inform you of the change from three bedrooms to four bedrooms. (design attached) We do not anticipate any adverse effects on neighboring WELL INSPECTION properties due to the change. & FLOW TEST If we may be of further service please contact us. Sincerely, SITE PLANS ROADDESIGN Robert C. Cowan, P.E. SOILTEST PERCOLATION TEST STRUCTURAL& MECHANICAL INSPECTIONS ONSITE WASTEWATER DISPOSALSYSTEM DESIGN 17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577 S&S1 ,ineeRtnG August 17, 1995 ROBERT C. COWAN, RE. ROBERTA. SHAFER, P.E. CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 HEALTH AUTHORITY APPROVALS MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 SEWER & WATER MAIN EXTENSIONS REFERENCE: Lot 6, Block 1, Knik View SSD Request you issue a permit to install a septic system to SEWER&WATER serve the vthree bedroom house on the referenced property. INSPECTION P'Q0 P4 i f J A test hole was excavated and a percolation -test performed. The approximate location of the test hole is located on the attached site plan. ENGINEERING STUDIES AND REPORTS At the time of excavation no water was encountered in the test hole and after seven day ground water monitoring, the monitoring tube was found to be dry. WELL INSPECTION &FLOW TEST This property has enough area for a future septic upgrade which can be seen on the attached site plan. We do not anticipate any adverse effects on neighboring SITE PIANS wells, septic systems or drainage patterns by the installation of the proposed septic system. If you require additional information, please contact us. ROAD DESIGN Sincerely, ;a(�Y.4 i��"`a-� SOIL TEST Robert C. Cowan, P.E. RCC/gk PERCOLATION Enclosure TEST STRUCTURAL& MECHANICAL INSPECTIONS ON SITE WASTEWATER DISPOSALSYSTEM DESIGN 17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577 Z FSO 0Z U O 0 as = O m r aV) 0 �0LJL: N U (n W Q wWml�=www tY �I�_W'Z clfQZrIIb�J OJ z w www ml�O LLJ(na�Zwa w F m (n Z w< vi _� re w0 Ld ch DOm�-TI,_w:D F ZEUCE Z S�Q 0>aN O - H Z 0 z G O UJ N F_ mw F- > W U U a- x w V� 0� USO Q ~ Z ZQO� OmmO v0[s.�y LO H O J W (n J Q r F- 2 Z F O 0 � O O (n CO Q - I- O U r � w mWw O ( I-- w Li r O N W12 V) w Z W V) w fif Z J H W V) g V) =004 f- U:;,- O U Z W r O w 0 OL O IL O 'o Lu `n O o w o (n E,-: �I 0 N \\ O N a- V) o O Hti OO 6-4 00 o Oo Q DO N F--- 0 J J m z w-� S N — 641 r ',wuj zm w N O W`ww�N 22� JV.Z p <0 NF 1a11� � L10 lwIzl =x o w14 ZO � � O \ W � � II N W U Z (�/ /I 0 ULw�0a; O � a7 mOo w ow� \ �!/?/fes c V) C/D/� v) c0 Of U-)r�i (D r7 0 `=d T �\ \ �! \41 co d' O 1V( nrl a, w aE�o NOIS3a NV1d 311S 1 OJ7 = „L z4 • J V _ N030 Q C� Nz3snOH N008038 {, a a3sodoad O U X1030 Ld — (/) a O w CL O � IL � co r F- 2 Z F O 0 � O O (n CO Q - I- O U r � w mWw O ( I-- w Li r O N W12 V) w Z W V) w fif Z J H W V) g V) =004 f- U:;,- O U Z W r O w 0 OL O IL O 'o Lu `n O o w o (n E,-: �I 0 N \\ O N a- V) o O Hti OO 6-4 00 o Oo Q DO N F--- 0 J J m z w-� S N — 641 r ',wuj zm w N O W`ww�N 22� JV.Z p <0 NF 1a11� � L10 lwIzl =x o w14 ZO � � O \ W � � II N W U Z (�/ /I 0 ULw�0a; O � a7 mOo w ow� \ �!/?/fes c V) C/D/� v) c0 Of U-)r�i (D r7 0 `=d T �\ \ �! \41 co d' O 1V( nrl a, w aE�o NOIS3a NV1d 311S 1 OJ7 = „L o Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 •'L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST CE -8801 PERFORMED FOR: I % SDATE PERFORME[S} F I a LEGAL DESCRIPTION: �"r l✓1��L 1 �.� 1� Township, Range, Section: \ SLOPE SITE PLAN 2 , 3 4 G 5 � 6 6•' 7 8 9 U 10- 11- 12- 13 0 11 12 13 14- 15 16- 17 81920 18- 19- 20 COMMENTS WAS GROUND WATER ENCOUNTERED? l O S IF YES, AT WHAT L O DEPTH? n P E MonttDepth to Wale At )(� _ 3�Ip�s Monitoring? l4`-JVr �fl —pale: Reading Date Gross 'rime Net Time Depth to Water Net Drop 2 _ � al PERCOLATION RATE 1 (minutesnnch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND S FT PERFORMED BY: S & S ENGINIeERING — I Irb i W", �o CERTIFY THAT THIS TEST WAS PERFORMED IN 17034 Eagle River Loop Road No. 204 ACCORDANCE WITH A1-�g$�TAJ E Ar,NDIaSU aICIPAl�UIDELINES IN EFFECT ON THIS DATE. DATE: '/2-008 (Rev. 4/85) G 1 NI 41 K YY7� s&S� 3ineeRznG HEALTH AUTHORITY APPROVALS SEWER& WATER MAIN EXTENSIONS ROBERT C. COWAN, P.E. ROBERT A. SHAFER, P.E. ON-SITE WASTEWATER DISPOSAL SYSTEM CIVIL ENGINEERS 694-2979 CONSTRUCTION PRACTICES FAX(AX (907) 694-4- 1211 and MATERIAL SPECIFICATIONS Lot 6, Block 1, Knik View SSD August 17, 1995 1. The scope of this project includes the installation of a 1000 gallon septic tank and a five foot wide SEWER&WATER drainfield -to serve the proposed three bedroom INSPECTION residence for the referenced property. 2. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with ENGINEERING STUDIES AND REPORTS y p � an special provisions or conditions and all applicable State and Municipal Wastewater Disposal Regulations, 3. The contractor shall be responsible for obtaining any WELL INSPECTION &FLOW TEST necessary underground utility locates. 4. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas SITE PLANS subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. ROAD DESIGN 5. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own SOILTEST systems must also receive prior approval from the Municipal Health Department. PERCOLATION SEPTIC TANK INSTALLATION: TEST 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. STRUCTURAL& MECHANICAL 2- The septic tank shall be sufficient) bedded to p Y INSPECTIONS prevent settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a ONSITE minimum of 12 inches above final grade. WASTEWATER DISPOSALSYSTEM DESIGN 17034 NORTH EAGLE RIVER LOOP - SUITE 204 - EAGLE RIVER, ALASKA 99577 Page Two Lot 6, Block 1, Knik View S/D August 17, 1995 4. Septic tanks installed with less than 4 ft. of cover shall be insulated. 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: 1. Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed --up) before gravel (sewer rock) placement. 2. Once the gravel .is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. 3. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 4. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. 5. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. Page Three Lot 6, Block 1, Knik View S/D August 17, 1995 MINIMUM MATERIAL SPECIFICATIONS: 1. Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the .inspecting engineer. 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the 4200 sieve. 7. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements. Page Four Lot 6, Block 1, Knik View SID August 17, 1995 INSPECTIONS: Typically there will be a minimum of three (3) :inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: 1. The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic: tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement: of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 2.4 hours prior to the start of construction. If necessary, a pre -construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor- to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will. inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR OWNER Municipality of Anchorage On -Site Water and Wastewater Program (907)343-7904 hUlfir RUSH! ; Certificate of On -Site Systems Approval Parcel I.D. 051-031-29 1. GENERAL INFORMATION Complete legal description Expiration Date: 7 - 2. J -1, Knik View S/D, Block 1, Lot 6 Location (site address) 22509 Inlet Vista Drive, Chugiak, AK Current Property owner(s) Gary and Susan Larsen Day phone 242-4763, 242-4761 Mailing address Real Estate Agent Audrey Mason, ReMax of Eagle River 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 Day phone 622-3344 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual El Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System U Public Sewer ❑ West lot !ire to !each field. 6' WaiverNariance request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ Oo 301- ZroS Date of Payment 13 Receipt Number 0o55 -I 1 COSA # 05C -I 31 � � a Waiver Fee $ �U^ 2D�,�u5 "p Date of Payment Receipt Number cx�'S-10 aS Waiver #_ o503 19df 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Douglas T. Kenley, P. E. Phone (907) 746-1073 Address 9806 E. Northstar Circle, Palmer, AK 99645 Engineer's Printed Name Douglas T. Kenley Date/ZS 13 ...d�A 49 1* 6. DSD SIGNATURE V System #1 Approved for --4—bedrooms e ', System #2 Approved for bedrooms 'r; t6E3 S% Disapproved�x� .? .1.3 Conditional approval for bedrooms, with the following sttiipula&''- V�Ilt By: Original Certificate Date:i The 6 niclp ty Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue shell;'- , c If more than 1 septic system Is on the lot: COSA Checklist # _of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Knik View S/D, Block 1, Lot 6 Parcel ID: 051-031-29 A. WELL DATA Well type Public Date completed Total depth ft Date of test Static water level Well production WATER SAMPLE Coliform l If A, B, or C provide PWSID # Sanitary seal (Y/N) _ Cased to ft. FROM WELL LOG ug/L g.p.m.. 00 mL Nitrate mg/L Date of sample: B. SEPTIC/HOLDING TANK DATA Tank Type/Material *Septic/Steel Well Log (YIN) Wires properly protected (Y/ Casing height (a ground) in. AT I CTI ft. g.p.m. Collected by: Dateinstalled "11/10/95 Tank size *1250 gal. Number of Compartments *2 Cieanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (YIN) N High water alarm (Y/N) N/A Date of pumping 7/24/13 Pumper JR'S Septic C. ABSORPTION FIELD DATA Date.installed 7/22/13 Soil rating (g.p.d./fe or ftp/bdrm) *0.8 System type Deep Trench Length 65 ft. Width 2.5 ft. Gravel below pipe 6 ft. Total depth 11-12 ft Eff. absorption area 750 ft Monitoring tube Y Depression over field N Date of adequacy test New system Results (PasslFail) For 4 bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) if yes, give date D. LIFT STATION Date installed Size in gallons "Pump'on"'level at ' in. "Pumpofr level of in. Datum E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot _ Absorption field on lot Public sewer main Sewer /seotielie­rvice line Cycles tested Manhole/Access (YIN) _ High water alarm level at Meets alarm & On adjacent lots On adjacent lots Public sewer manhole/cleanout Holding tank Arflmal containment areas Manurelanimal excrete storage areas SEPTIC/HOLDING TANK ON LOT TO Building foundation 5+ k Property line 10+ ft. Absorption field 5+ ft. Water main 10+ ft. Water service line 10+ ft. Surface water 100+ ft. Wells on adjacent lots 200+ ft. ABSORPTION FIELD ON LOT TO: Property line **6ft. Building foundation 10+ ft. Water Service line 1'0+ ft. Surface water 100+ ft. Curtain drain None Known Wells on adjacent lots 100+ft. Water main 10+ ft. Driveway, parkingNehide storage 5+ ft. F. COMMENTS *From M.O.A. records. ** Waiver is requested for separation of leach field to west property line. See attached letter. G. ENGINEER'S CERTIFICATION i certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Douglas T. Kenley Date 7/25/13 COSA brown shee1JD-1D-12.doc [fil it M, W,1FA UN�t:Ii IX, AN -s- JUK.-I D -01,M %M.i�R'I,': ESTAGtjFtflNc, EKUFI&A'y OR FEiIUNES. N!" AI- -,kUANu,'Y ONLI OR 'ME COST 07 Tt-lE SURVEY. FWkCr,2- IN SCALV 0,,,AF (�Of 1JCT!CNIC- VFLR:FPROPOSED BUOIrtAC'_Lk 11c -,U MtIJSHE0 URAM AND UII I1 ON i C v AND 10 OEl-,RVINE iHE FYISIDICE Of ANY -A3A_VFNiS,d Vq 0RS_"CTIONS 0T PLIV _,.h t— , .I Att Q I -C,t, ... . . . ...... . A; Qr� I _� ASPHAL" "R . .... ID- "Or3 FENCE t nNu,ETE 0,rx 1 Q, Y -IM AAPROEMEJN.EQI'iE CRO ND ANO VEISLE NklLL BE ?,&ils, SFP.rc _,-CANOUTS, SOFWAL.KS. MR IS C., ARE SC _IN N THEIR APIROXIMATE LOCATION, ONLY. SNOW I AY PR_'VFM7 SOME IMPRO'EMETAS ROM BEING SEEN AND LOCATED. AI_;_ D 'NCIS i,FE NCCCRC, UNLESS OTHERWISE NOTED. R-eccred, by i s 7 fin 0: Lana -vievc)rs 1,534 uJOl 07/ 1, 23 /131 -C As s oC. t "r, 06 t, !CEJ5AK V0 1135-335 f C.0.s /4( UN�t:Ii IX, AN -s- JUK.-I D -01,M %M.i�R'I,': ESTAGtjFtflNc, EKUFI&A'y OR FEiIUNES. N!" AI- -,kUANu,'Y ONLI OR 'ME COST 07 Tt-lE SURVEY. FWkCr,2- IN SCALV 0,,,AF (�Of 1JCT!CNIC- VFLR:FPROPOSED BUOIrtAC'_Lk 11c -,U MtIJSHE0 URAM AND UII I1 ON i C v AND 10 OEl-,RVINE iHE FYISIDICE Of ANY -A3A_VFNiS,d Vq 0RS_"CTIONS 0T PLIV _,.h t— , .I Att Q I -C,t, ... . . . ...... . A; Qr� I _� ASPHAL" "R . .... ID- "Or3 FENCE t nNu,ETE 0,rx 1 Q, Y -IM AAPROEMEJN.EQI'iE CRO ND ANO VEISLE NklLL BE ?,&ils, SFP.rc _,-CANOUTS, SOFWAL.KS. MR IS C., ARE SC _IN N THEIR APIROXIMATE LOCATION, ONLY. SNOW I AY PR_'VFM7 SOME IMPRO'EMETAS ROM BEING SEEN AND LOCATED. AI_;_ D 'NCIS i,FE NCCCRC, UNLESS OTHERWISE NOTED. R-eccred, by i s 7 fin 0: Lana -vievc)rs 1,534 uJOl 07/ 1, 23 /131 -C As s oC. t "r, 06 t, !CEJ5AK V0 1135-335 MUNICIPALITY OF ANCHORAGE ' DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # - 0 S/ 0 3 /a i HAA # 1. GENERAL INFORMATION Complete legal description Lot G; Stock 1; Knik View Location (site address or directions) NHN TYV-et Vista Dative Chuaiak. AK Property owner red Schme2zeh Day phone Mailing address P.O. Sox 799 Man.yhvitTe, WA 98270 Lending agency Mailing address Agent Address Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: _ 4 3. TYPE OF WATER SUPPLY: Individual well Community well XXX Public water Day phone Day phone NOTE: If community well system, provide written confirmation from State ADDC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site XXX _ Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) From MOA -21 S. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm S & S ENGINEERING Phone 6 `)h - �`j age )ver Coop Roail No. 204 Address Eagle River, Alaska 99577 T Engineer's signature 6. DHHS SIGNATURE Approved for bedrooms. Disapproved. Conditional approval for Additional Comments Date c / ( / q c OF q , i ;e [ ROBERT C. COWAN.••lf�� CE -ZuJI A bedrooms, with the following stipulations: 1tITir Date G y� The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in orderto satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 1791) Rack MOA r2t Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES RECEIVE Environmental Services Division 825"L" Street, Room 502 • Anchorage, Alaska 99501 • (907) 343-4744 JUN 6 1996 Health Authority Approval Checklist DOW. Health l lth& Human Survlces Legal Description: Lel_ 6 enik V ecu-' Parcel LD.:_ A. WELL DATA Well type A If A, B. or C, attach ADEC letter. ADEC water system number a 1.9 4/0 9 og present (Y/N) Total dept t Sanitary se�(Y/N) Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform Date of sample: B. SEPTIC/HOLDING. TANK DATA Date completed _ Cased to \4 WELL LOG Nitrate Casing height (above ground) Wires properly protected (Y/N) AT INSPECTION Other bacteria Collected by: Date installed II - I I - q S Tank size I f1i� Number of Compartments — P, Cleanouts (WN)4— Foundation cleanout") �[_ _ Depression (Y qI L( High water alarm (Y/N) Date of Prunping — r0-- 1 Pwnper -- n/ a. C. ABSORPTION FIELD DATA Date installed I I - ! _ Soil rating (g.p.d./ft' or ft/bdrm) /, 2 qPd System type J19//oc� �ien Length SS ' _Width _ S Gravel thickness below pipe 2 � Total depth S � Effective absorption area `��'�� -Monitoring Tube preseutCY)N) —t/ Depression over field (Y�J rI Date of adequacy test F �� Results (Pass/Fail) _ —7— For _ - __bedrooms Fluid depth in absorption field before test (in:); Immediately after i gaL water added (in.): - Fluid depth (ns.) Minutes later:___ Absorption rate==9-p.d. Peroxide treatment (past 12 months Y ) (I ) ( �'' � [f yes, give date D. LIFT STATION Date in d Manhole/Access (YIN) High water alarm level at* Cycles tested E. SEPARATION DISTANCES Size in gallons "Pump on" level at* "Pump off' level at* SEPARATION DISTANCES FROM WELL ON LOT TO: kll " C&mmu "' i7 Y C'4 6C Septic/holding tank oil lot Absorption field on lot Public sewer main Sewer /septic service line Oil adjacent lots On ad' ots sewer manhole/cleanout Lift station SEPARATION DISTANCES FROM &EPTICHOLDING TANK ON LOT TO: r Building foundation Properly line t D Absorption field Water main/service line IJ Surface water/drainage o� t .)— Wells on adjacent lots L•o p�_ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Building foundation 3� / Water main/service line / h� r �tk Surface water l00 Driveway. parking/vchicle storage area L.'> Curtain drain ntsn e— k176f,k, Wells on adjacent lots L v0 Property line /Q . F. ENGINEER'S CERTIFICATION 1 certify that 1 have determined thru field inspections and review of Municipal records in conformance with MOA HiM guidelines in effect on this date. Signature L C �i✓' ' �J Engineer's Name z` a��f� i o c Air ►3•• E' Date SO HAA Fee $ 2 J . 4-0 Waiver Fee $ _ Date of Pavment / (�� Date of Payment Receipt Number (/ e�� Receipt Number Rev. 8/95 OSS: haa.wk.doc �, O ROBERT C. CO\ CE - 8001 are