No preview available
HomeMy WebLinkAboutMCKINLEY HEIGHTS #1 BLK 7 LT 7A MUNICIPALITY OF ANCHORAGE Department -f Health and Environmenta? ~'~rotection 825 Street, Anchorage, AK. _3501 264-4720 Permit ~--~lk'~'. , ~-WELL AND/OR ON-SITE SEWER PERMIT ~-/ Location: Phone Nu~er: ~¢'¢ - J-Type of Soil ~sorption System Is: Legal Description: ~-~//J ¢~ /~;~¢/~2--~%'¢ /// Lot Size: Trench: Drainfield: Se~age Bed: ~ Holding Tank:,~ Maximum Number of Bedrooms: ~ Soil Rating(sq.ft/br) The Requ~.red Size of the Soil ~sorption System Is: - LENGTH <3) GRAVEL DEPTH ~~'/~t~'¢'"~'~'43>~ ''¢¢/*/ The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minim~ depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE = /~ ~ GALLONS Permit applicant has the responsibility to inform t~is department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this department will be subject to prosecution. ~inimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minim~ distance from a private well to a private sewer li~e is 25 feet and to a co~uni%y sewer line is 75 feet. Well logs are required and must be returned to this department withi~ 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 1 9 8 3 * * I certify that: (1) I ~ f~iliar with the requirements for on-site sewers ~d wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (B) I understand that the on-site sewer sys%em may require enlargement if the residence i~ remodeled to include more that 3 bedrooms~ ~ ,/ , Date: ~6 SWP/024 (1/81) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG -- PERCOLATION TEST / SOILS LOG [] PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4 5 DATE PERFORMED: t~,v ~..e ,," t'¢z ,~', SLOPE SITE PLAN 10 11 12 13 14 15 16 COMMENTS PERFORMED BY,: 72-008 (6/79) WAS GROUND WATER mOOU~TERED? __l/~!zS' ~ .... IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE ,/~// __(minutes/inch) "FE~ ;IUN F,T CERTIFIED