Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MOUNTAINSIDE VILLAGE BLK 3 LT 8
Mountainside Village Block 3 Lot 8 #020- 172-27 (Roy I:MO) • Municipality of Anchorage • } r, Development Services Department .. . ;ii9'Building Safety Division -'% -1 On-Site Water and Wastewater Program. 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page www.d.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SW020410 PID Number. 020-172-27 of None Troy Nibert Wastewater System: 0 New ■ Upgrade P.O. Box 111428 Anchorage, AK 99511 ABSORPTION FIELD Rome 336-8769 Number Of Boxrooms:4 CI DeepTrwmdt m Shallow Trench Died ❑Mand Qomar LEGAL DESCRIPTION MaurySod .45 GPDFP 4 Tar Demon am antral wadi n Moot Lot Sub:Ic a 3 8 Mountsinside Village Depth M pp. bottom hon agCP Vele 1 FI GC CI ower PP, 3 n Townwq' Rwga Samar FM woad aw%a ontinal 7.de 2-4 FT Grave Longo 156 R. Well: New ■Upgrade pmt 5 Ft. Number firm Dwwta.aarcInes Ft CMsarhracn (Private A. e. C) Prate Taw Dawn 223 Ft. Cased to 28 Ft Tatar Ppa Matanal ASTM D3034 PVC aow,puon dna 1,344 Ft' Darr Alpine Drilling Dao D ale 7/21/05 Stew www Lawn 39 rt inatnlr. Poor Boy Construction Data initamart 7/26-31/2003 Yeme 2 GPM Pump Ser at R. Gump teen Above Gerund 4 n TANK SEPARATION DISTANCES aseptic ■ Holding ❑S.T.E.P. ■ Other. To From Septic Tank Absorption Field Litt Station Holding Tank W AG/Prtv.te Sewer LineAnchorage Marv.hasef Tank Capa°Ir 1,250 am loves >100' >100' N/A N/A >25' Maw Steel Nuwo(2camwarenM. or sten weer >100' >100' N/A N/A LIFT STATION La Una >5. >10' N/A N/A 5.... Gm Manufacturer Faacabon >5' >10' N/A N/A 'Pump are Meant at In 'Pup or M.w at rt t*pn water warm at In amino-am None Noted Pump Mama & WON Elwbrr ae Ilwecxm °shmor Ren 2" Insulation Over Tank and Absorption Trench. BENCH MARK Louwn moa Lectern Lower Level Slab. Assumed Eavatron. 100.0 FL .- .. 1. i,, eiirea'1R,1 ' y. 0 1:',....74.0.1101.1J3.00000 � ►� X41 P-No,,eeeaeeenL4//1 °IV O e.«49 '... R ..... *ea 0 a • µ"al t ANDERSON � : .• CE-4381 ";��i.MP ref o- 00000.•a•Sat 11t1�80►[SStO�"-48" All `' n .7/26/03 Inspections performed by: Dates: 1 _ ::j.".' 2 and 7/28/03 Development,Services Department Approval Conditional Approval by: / Date: _ Reviewed and Approved b . 4 - " a/' , 4u Date- 7/�y1LAa (Roy I:MO) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) • DATE: July 5, 2008 TO: Deb Wockenfuss FROM: Mike Anderson, P.E. SUBJECT: Lot 8, Block 3, Mountainside Village Subdivision Septic System Permit Upgrade Permit No. SW020410 The septic system on the subject lot was constructed between July 29 and July 31 of 2003. The well was installed on July 21, 2005. The surveyed as built was not completed until February 7, 2006. On June 29, 2006 a letter was sent to the owner that additional fill was still needed over the septic tank and absorption field before a certified as built could be completed. To my knowledge the house was not inhabited until some point in 2006. No Certificate of On Site System Approval was ever requested for the lot. During the construction process we found inconsistent soils at the location of our original approved design location. We then completed additional test holes and determined the best design for the absorption trench was a single long trench. Our records indicate we called Joe Gooddall of the City and discussed the changes in July of 2003. We stated a splitter valve would be used and the trench would be entered in two locations. We also stated soils encountered in the single long trench were far superior to those encountered in our original test holes. No request was made for a revised site plan and we assumed the redesign had been approved. There was no policy at the time for a redesign fee. The following responses are provided to review comments: 1. No redesign fee for the reasons mentioned above. 2. The well was installed in July of 2005. No pump installation report was required at the time. 3. Test Hole Nos. 5, 6 and 7 are attached. 4. The absorption trench design did not change. One trench was installed instead of two. A design calculation is attached. 5. The trench is entered at two locations with the use of a splitter valve. The effective area for each entrance is 78'. 6. Engineering statement as to the history of the project is presented above. Permit No. SW020410 a: 49th P1 ?' a 1.3 ;11100a E. ANDERSON t -•1/'.7(7T1 No. CE -4381i �� 0 • -+4-6 't sesPRCFESSOte. %%%%%%%%%%% Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Bragaw Street Anchorage, AK 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Page 2 of 3 PID No. 020-172-27 LOT 8, BLOCK 3 MOUNTAINSIDE VILLAGE SUBDIVISION PLAN AS -BUILT SCALE 1' - 50 63,618 S.F. Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number. SW020410 In u N S Page 3 of 3 PID No. 020-172-27 L d 4- 4- = o. C0. d 3i 0 Lo t 1- 87.6 / S u u 2' Insulation I. Geatextlle Fabric 85.9 i Drainfleld Rock 1e— ...--------85.5 1 82.9—f 82.9-7 156' (Trench Length) 75.5 NOTE. Trench Is Entered at 2 Separate Locations. PROFILE AS -BUILT No Scale I .4.7.7.‘ 49th P • s_._ .1, MICHAEL E. ANDERSON •41 No. CE -4381 1 `i LOT 8, BLOCK 3, MOUNTAINSIDE VILLAGE SUBDIVISION DESIGN FACTORS: Four Bedroom Home Perc. Rate: 31-60 Min./Inch Application Rate: .45 GPD/SF SYSTEM REQUIREMENTS: 5' Wide Trench System 1,250 Gallon Septic Tank 3' Drainfield Rock 4 Bedrooms X 150 GPD/.45 GPD/SF (Application Rate) = 1,333 SF Absorption Area 1,333 SF/5 SF/LF•.58 (Red. Factor) = 154.6 LF Trench Length THEREFORE: Construct a 155' Long x 5' Wide x 3' Effective Depth Absorption Trench at the Location Shown. Flow Line Elevation in Trench to be 1' Below Original Ground Surface. Total Depth to be 4' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Maintain 100' Separation from Wells in the Area. Place a Flow Splitter Valve and Enter the Trench in at Least Two Locations. Natural Backfill 4'0" 5' 2" Insulation 8 Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION ..•••••:a (NO SCALE) 4r. P�E "• �� Grade Area Over Trench to Drain Away. 5 4 / 49th NOTE: Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. • : n i L c Minimum 100' Separation From Wells in the Area. ;••�`• ..._... ._ MICHAEL EANDERSON Minimum 100' Separation From Surface Water or Streams: �i `•.• No. oe+an / fe • LOT 7 `11 a4e �E OF A.gsi11 ••.»sees.. ,F d 7s5 k • SPP fi Lot 8 , Block 3 Main loin side Vi//ate Suto Archcroge Recording District, A:ocko J,.0'I SURVEY CERTIFICATION 1 hrshy certify 'eat IMrs ma -rayed the property Lunn and described hereon, and that au Impgwn .rets situated, mese ore within the prop- erty 14... and depot or.r:ep or encroach on od jaunt erop.ety and that M le rorep"nts on adjacent property overlap or aneroanh op 1M promisee 1, sw.tloc and Chet then ars so roadooys, utility Ibex. or other visible so temente on cold property neat a Indicated harem. 0 ,. O S � : R. L. Button 411 srF!. LS -1192 `aJQA R. Casements of mooed .hear then Mow show M MO plat of record ere *0f Mang hereon Ylcce otherwise noted. LEGEND • Broca or Aluminum copped monument recovered O Iron pipe and/or mbar recovered. o 2 x2 nab 6 tock recovercd • 5/6"x 50. rebor set this survey BASIS OF VERT/CAL Q4TL/M 1927 MSS. /972 ADJUST: •e 88�!iLOF 3 t .j 02-0T-ClCs Date (0; 0Z-2/-03 E B. No _75 Prepared by: R. L. BUTTON Rspistsred Lord Surveyor (907)279.6200 5/9W. EiµryhAve. Axha-oge Mach 9950 Property of: fAc?Mrsa Tic3/ Mteit INVOICE NO. 06-165 June 29, 2006 Troy Nibert P.O. Box 111428 Anchorage, AK 99511 Subject Lot 8, Block 3, Mountainside Village Subdivision Septic System Layout, Inspection, As -Built and Certification Dear Troy: Attached is a copy of the completed and certified as -built for the well and septic system on your lot. You still need .to place more fill over the septic tank and drainfield. A minimum of 2' is required over both the tank and the field since you have insulation in place. Our measurements indicate you only have 1' of cover. The total due for our work to complete the work is el This amount includes a total of 16 hours of time for the layout, inspections, field measurements, drafting and as -built certification. In addition, several additional test holes were required and field design changes made to accommodate the longer trench. All work took place between July 28 and July 31, 2003. Recent inspections were made in May of this year to finalize the as -built. Please let me know if you have any questions. Sincerely, Michael E. Anderson, P.E. Attachment VISA AND MASTERCARD ACCEPTED Performed For. Legal Description: Depth ',Fact) 1- 2- 3- 5-1 GM 6- .7- a- . 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20 - Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage. AK 99519-6650 WAW et.anchorage . ak. us (907) 343-7904 Soils Log - Percolation Test Lot 8, Blk 3 Mountainside Village y`.\\Shope l� -pr/o6- 0 t•-•' - ot— city COMMENTS/'- 'Gamy, unship V ' 'I . ?mama t Armt:ltsor4; .a„ i'Ct. �o. CE.4381 j �i�- • It Date Performed: WAS WATER ENCOUNTERED? IF YES, AT WHAT DEPTH?� L Depth to WatetAfter 'D P. Monitoring? Date: lb/ 103 3 1 Reading . • Date Gross Time Net Time Depth to Water Net Drop ?12y/,b3 11'1 5.1o3 • II148 -ice 6.s I. I;I,• • i i �L 1221, - 3o L.+� 1 x.25 iti:24 — .-I`i (v;ii 30 • tery (, Z9 - 'Z -'f (mwM..hicn) rtna, TEST RUN BETTW�—EEN i- FT AND its) FT W e derr PERCOLATION PATE PERFORMED BY: l CERTIFY THAT THIS TEST WAS • PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 1 Performed For. Legal Description: 1- 2- 3- 4- 5- 6- .7- 8- . 9- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20 - Depth (Feet) 4 IMO Municipality of Anchorage Development Services Department Building Safety Division On -She Water and Wastewater Program 4700 South Bragaw St. P.O. Box 195650 Anchorage. AK 9951.9-6650 www CI. anchorageek. us (907) 343-7904 Soils Log - Percolation Test rpoy sJIgaT Lot 8, Bik 3 Mountainside Village C �" oV 6H � c Slope CT• WAS GROUND WATER ENCOUNTERED? • IF YES, AT WHAT DEPTH'? Depth to Water. After Monitoring? Date Date Performed: Nnship, Range. Section: 1 mil I o S She Plan a t. O P E iii ■■■■■■■.f■ Reading -• Date Gross Time Net Time - Depth to Water Net Drop 14.joT rv;4i' - 1.tcq • !Pie '5 0 8 .,0 0.81 • 13:11 1.1v3 is: `t1 •3o F$7 •c.ffb 11:IfF 'I. Y rf:I. 30• -8,31 p•8! r) a PERCOLATION RATE N+t.M ) PERC HOLE DUe+4ET TEST RUN BETWEEN .O FT 'AND 0'4,55 FT COMMENTS &i t }04i 17at°ieK>K PERFORMED BY: � CERTIFY THAT THIS TEST WAS • PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 1 Performed For. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 195650 Anchorage, AK 99519-6650 www.cl. anchorage ek. us (907)343-7904 • Soils Log - Percolation Test Trey rJItiett.j Legal Description: Lot 8, Bik 3 Mountainside Village wnship, Range, Section: Slope 1a` o✓ O M O '.• ENGIt**** b �(� a '-P: ' , 491y P A * • :n......g. .4 . SON; CE.4381 10ceE♦SSt��.,te� Date Performed: 1:4`,-/(-Y/ �' 3 1- 2- 3- 4- 6- .7- 6- 9- 1O;- 111 12- 13- 14- 15- 16- 17- 18- 19- 20 - Depth (Feet) 0fl COMMENTS 1�5f'a,rtr WAS GROUND WATER , 1 Site Plan ENCOUNTERED? ' 1 I IF YES.AT WHAT DEPTH? ftWAW/It— C Depth to Water After `I p KP. Monitoring? i 1 E . Date: 'I�o3 Reading • • Date Gross Time Net Tane Depth to Water Net Drop j 11140 03 (ill ! Li. (PS ' � • l/ 43 3-2. .5c, 04,5"WWI43o / 17/j/43 n 5.7, ) .o.ar .. / 6.,Iri 1.(,:15.1 3:00 3o • . 5.9e, C.¢1 PERCOLATION RATE 31 I ••Mn8) [ PERC TEST RUN BETWEEN t)':O FT 'AND -4., FT PERFORMED BY: j• 1 CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: /O° ca, 0GZA, A, 4 to /O' i n, 1- t" • 11111111111 NEE a — k. of cvl m [nn• � 4• kit° • 40 It 28_ OS S LoES/vT( a 1 26 6 lot N /6?551CO" W 0 ALPINE DRILLING & ENTERPRISES Permit Number: #S W0501 Date of Issue: 6-3-05 Parcel Identification Number: 020-172-27 Date Started: 7-20-05 Date Completed: 7-21-05 Is well located at approved permit location? ® Yes ❑ No Legal Description: Mountainside Village Blk 3 Lot 8 Property Owner Name & Address: Troy Nibert PO Box 112203 Anchorage. Alaska 99511 Borehole Data: Soil Type, Thickness & Water Strata stick-up gravelly silt fill organics & silt gravelly silt bedrock H2O Depth (ft) From To 0 4 4 8 8 9 9 23 23 246 218 2D3 Method of Drilling 0 air rotary ❑ cable tool Casing type: steel Wall Thiclm:ss:250 inches Diameter: 6 inches Depth: 28 feet Liner Type: Diameter: inches Depth: feet Casing stickup above ground: 4 feet Static water level (from ground level): 39 feet Pumping level: 246 feet after 8 hours pumping 2 gpm Recovery Rate: 2 gpm Method of Testing: eir--lift Well Intake Opening Type: ❑ Open End 0 Open Hole • Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet Grout Type: bentonite granules Volume: 1 g Depth: Start 0 feet Stopped 2 feet Pump: Intake Depth feet Pump size hp Brand Name Well Disinfected Upon Completion? 1�1 Yes ❑ No Method of Disinfection: chlorine tablets Comments: Well Driller: Alpine Drilling & Enterprises PO Box 110496 Anchorage AK 99511 Ate:ation: The well driller shall provide a well log to the property owner within 30 days of completion and the property e MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WATER SUPPLY PERMIT Initial Date Issued: Jun 03, 2005 Expiration Date: Jun 03, 2006 Permit Number: SW050163 Parcel ID: 020-172-27 Legal Description: MOUNTAINSIDE VILLAGE BLK 3 LT 8 Design Engineer: 0000 None Required Site Address: 017640 MOUNTAINSIDE VILLAGE DR Owner Name: TROY NIBERT Lot Size: 63618 SQ. FT. Owner Address: 17640 MOUNTAINSIDE VILLAGE DRIVE Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE . AK 99516 - This permit is for the construction of: ❑ Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3_ The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by catling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. -WHEN THE WELL HAS BEEN COMPLETED AND SATISFACTORY WATER PRODUCTION HAS BEEN DETERMINED, THE WELL DRILLER SHALL PLACE AN APPROVED SANITARY SEAL ON THE WELL HEAD AND NO PITLESS ADAPTER OR PUMP SHALL BE INSTALLED UNTIL AN APPROVED WASTEWATER DISPOSAL SYSTEM HAS BEEN CONSTRUCTED AND APPROVED. Received By: aiY/e Date. Issued By. Ir Date: (t/1/„f Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 0,70 Permit Number SW Property owner(s) /Ady /�/> bd7z_r Day phone Mailing address ��JJ 9' Zip Code Site address /1640 MO/.Ltid/acaxCc YG�c c.y A*, Zip Code 9`9S7G Legal description (Lot, Block & Sub'd.) Legal description (Section, Township & Range) `Vg!y 7/q.U/,Oi r Via" At Atmel Lot Size b3b(8 Acres/Sq.Ft. Number of Bedrooms a- LI - THIS APPLICATION IS FOR: Sewer Only 0 Well Only 0 - Sewer and Well 0 Water Storage 0 Sewer Upgrade 0 THIS PROPERTY CONTAINS: Hot Tub 0 Jacuzzi 0 Swimming Pool ❑ Water Softening Unit 0 Therapy Pool 0 I certify that the above information is correct. I further certify that this application is being made for a Single Famiyr D ell' g and is in a ordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: /4-S- 'op Waiver Fees: Date of Payment: ' 72%5- Date of Payment: Receipt Number: &A5D Olgt Receipt Number. (Rev. 09/04) . , / / /_/ ./1 1 ;/ / 1 1 11 1 1 / 1 t 1 YDUMMmOE MACE 50;1 ► 1 LOT 2. BIOGC J: 1 1 V0lMfAM51OE MIME SD; ��`� 1IAT t, BLOCK ]; i 1 1 `... 1 / ;1 \\•` 1 1 . `.�• • \ `NA / . N. `.� /\1` \\ / •``\ 1 . N. \ \ / 1 1 ; 1 �� 1 1 t 1'• t .1 . 1' • nab ^ tury tone \\ LDCAtCN 1 \•` • 1 \\ • `%� ` ` / • / �.• • •`\ MOUNWAWSCE MACE S? LOT 4. BLOCK •: / MDUNTUNStDE VILLAGE B15; LOT S, CLOCK •; / 11 1 1 �VACANTJ \\ • • AREA SYSTEM PLAN SCALE 1" =100' • • •`-----� Permit Number: Legal Description: Design Engineer: Owner Name: Owner Address: MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial SW020410 MOUNTAINSIDE VILLAGE BLK 3 LT 8 0014 Anderson Engineering Troy Nibert PO Box 111428 Anchorage , AK 99511 - This permit is for the construction of: Disposal Field✓J Septic Tank Holding Tank Date Issued: Oct 14, 2002 Expiration Date: Oct 14, 2003 Parcel ID: 020-172-27 Site Address: 017640 MOUNTAINSIDE VILLAGE DR Lot Size: 63618 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 Privy [✓ Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: 711-4-CLJ Date: Id— Issued By: n;(71 - Date: %4//4/G2- Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 020.172.27 Permit Number SW0Z04/O Property owner(s) Troy Nibert Day phone 223-8830 Mailing address (1) P.O. Box 111428 Anchorage, AK 99511 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) Lot 8, Block 3, Mountainside Village Estates Subdivision Legal description (Section, Township & Range) Lot Size 63,618 SF Acres/Sq.Ft. THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool Number of Bedrooms Four (4) ❑ Well Only Water Storage E Jacuzzi ❑ Water Softening Unit I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. d�^•� , (Signature of property owner or authorized agent) Permit Fees: 55-0 °^ Waiver Fees: Date of Payment: /0 9 0 L Date of Payment: Receipt Number: Z tit `F Receipt Number: (Rev. 12/00) October 9, 2002 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 8, Block 3, Mountainside Village Estates Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 8, Block 3, Mountainside Village Estates Subdivision intends to construct a new four-bedroom home on the property. We are therefore requesting a permit be issued for the construction of a new well and septic system to serve the new home. The attached Site Plan and backup documentation identify the location and configuration of the new well and septic system and the parameters. used in the design. Also identified on the plans are the alternate site, test hole locations and wells on the surrounding lots. Drainage arrows are also shown and current drainage patterns will be maintained after construction. The test holes placed near the location of the proposed absorption trenches indicated gravel silt contents up to 20% of the total. The percolation rate on the material was measured at 36 to 53 minutes per inch. Ground water was found at 8'below the surface in Test Hole No. 2 and 12' in Test Hole No. 1. Water levels remained at these elevations during the monitoring period. We are therefore proposing to construct 2 — 38' long x 5' wide x 3' effective depth absorption trenches. The distribution piping depth will be 1' below the surface with a total depth of 4'. A flow splitter valve will be placed to assure even flow to each trench. The ground surface on the lot slopes at varying grades from south to north. The absorption trench will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. All components of the new septic system will be constructed a minimum of 100' from the wells in the area. The system will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. Lot 8, Block 3, Mountainside Village Estates October 9, 2002 Page Two 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments /1// / / l / / J l /// 1 \I - kAOUNTAINSIDE VILLAGE SD: //l J! • `\\\ N. \\ \\ / \�\ \\ / C\\ \\ \ \ \ / 9 \ \\ \\ / / / \ 1 \\\ // / 11 \\ \ .... _ _ ,/ I 11 1\ 11 \\ I 1\ I I\ • I` \ / V - nag) -VEa1F`/ ..m.ne \ \\ LOCATION 1 \ MOUNTAINSIDE VILLAGE SO; LOT 9, BLOCK 3; `-YACANf� • N. / / MOUNTAINSIDE VILLAGE 4 LOT 5, BLOCK 4; / / // 1 MOUNTAINSIDE VILLAGE SD; �-.- \ // LOT 4, BLOCK 4; CZCAN2) \ • r-- 78' Long 5' Wide ' Effective D bsorption Trenches 1,250 Gallon Septic Tank Four Bedroom Home LOT 8, BLOCK 3, MOUNTAINSIDE VILLAGE ESTATES SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Perc. Rate: 36-53 Min./Inch Application Rate: .45 GPD/SF 5' Wide Trench System 1,250 Gallon Septic Tank 3' Drainfield Rock 4 Bedrooms X 150 GPD / .45 GPD/SF = 1,333 SF of Absorption Area 1,333 SF/5 LF (Width)*.58(Red. Factor) = 154.6 LF Trench Length Therefore: Construct 2 — 78' Long X 5' Wide X 3' Effective Depth Absorption Trenches. Flowline Elevation in Trench to be 1' Below Original Ground Surface. Total Depth to be 4' Below Existing Ground. Place a Flow Splitter Valve to Assure Equal Flow to Each Trench. All Components of the Septic System to be 100' From All Wells in the Area. NOTE: 6" 3' 2" Insulation & 2' Co or Geotextile Fabric & 3' Cove 5' 2" Direct Bury Insulation 4" PVC ASTM D3034 Drainfield Rock TYPICAL WIDE TRENCH SECTION (NO SCALE) Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 10' Separation From Lot Line. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG PERCOLATION TEST Performed For: Troy Nibert Legal Description: Lot 8. Block 3. Mountainside Village SLOPE Date Performed: 4 5 6 7 9 10 11 OG/PT TESTHOLE NO. 1 Gravel with Silt GM 20% Silt Bottom of Hole 16% 10% Was Groundwater Encountered? Yes If Yes, What Depth? 12' Depth to Water After Monitoring 12' Date: 10/7/02 Ai S L 0 P E 9/28/02 Reading Date Gross Time Net Time Depth To Water Net Drop 1 29 -Sep 1:04 1.5" 2 1:34 30 2.07" .57" 3 1:35 1.5" 4 2:05 30 2.07" .57" 5 2:06 1.5" 6 2:36 30 2.07" .57" Perc. Rate: 53 Min./Inch Perc. Hole Diameter: 6" Test Run Between 5 Ft. and 6 Ft. Comments: Percolation Cavity Presoaked Prior to Testing. Performed By: Alan Harala. I Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 10/9/02 Performed For: Troy Nibert Legal Description: Lot 8. Block 3. Mountainside Village SLOPE Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG PERCOLATION TEST Date Performed: OG/PT TESTHOLE NO. 2 Gravel with Silt GM Bedrock 16% 10% Was Groundwater Encountered? Yes If Yes, What Depth? 8' Depth to Water After Monitoring 8' Date: 10/7/02 Ak L 0 P SITE PLAN Reading Date Gross Time Net Time Depth To Water Net Drop 1 29 -Sep 1:08 2.25" 2 1:38 30 325" 1" 3 1:39 2.25" 4 2:09 30 3.13" .88" 5 2:10 2.25" 6 2:40 30 3.13" .88" Perc. Rate: 36 Min./Inch Perc. Hole Diameter: 6" Test Run Between 4 Ft. and 5 Ft. Comments: Percolation Cavity Presoaked Prior to Testing. Performed By: Alan Harala. I, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 10/9/02 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 8, BLOCK 3, MOUNTAINSIDE VILLAGE ESTATES SUB. GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,250 -gallon septic tank at the location shown on the site plan and the construction of 2 new 78' long by 5' wide by 3' effective depth absorption trenches also shown on the Site Pian. The total depth of the trenches will be 4' below existing ground and the distribution pipe will be placed at 1' below the surface. A flow splitter valve will be placed to assure equal flow to each trench. All components of the new absorption trenches and septic tank must be constructed a minimum of 100' from wells in the area. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,250 -gallon septic tank must be procured from a certified septic tank manufacturer. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. Lot 8, Block 3, Mountainside Village Estates October 9, 2002 Page 2 of 2 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1 The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). Lot 8, Block 3, Mountainside Village Estates October 9, 2002 Page 3 of 3 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. PERFORMED FOR: LEGAL DESCRIPTION 2 - 3- 4 - 5- DEPTH (FEET) 6 7 - 8 SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION TEST 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG — PERCOLATION TEST �Q f 53' 63/0ck DATE PERFORMED: -'- 30 -iv 1 C)1rj 2 1 t C Oe,e_ 9f�.P 111) 12 13 14- 15- 16- 17- 18- 19- 20 - COMMENTS 544 oil ©• 0 )CIL SLOPE WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Ss L P / / SITE PLAN lki Reading Date Gross Time Net Time Depth to Water Net Drop 1 /z 36 0 / • iFc e- 2. 12 'tb /0 141/ e, z7 3 /Z f6 /0 e• 2s- 0. I ? 1 /3 i. /0 O-�v 0 •/O PERCOLATION RATE TEST RUN BETWEEN 'J FT AND e0 e ?1/ q'/a it. A 744. PERFORMED BY: 131d/" 2% eh-- CERTIFIED BY: 72-008 (6/79) /(minutes/inch/ 6 FT DATE