HomeMy WebLinkAboutMOUNTAIN MANOR BLK 2 LT 11Mountain Manor Block 2 Lot I I #050-671-12 Municipality of Anchorage On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP201181 PID Number: 050-671-12 Dwelling: 011 Single Family (SF) F� with ADU El Duplex (D) F-1 Two Single Family Project: El New FIC Upgrade Name JOSHINGRAM A RPTION FIELD F-1 De Trench 1771 Wide Trench F-I B d ound Ze Site Address 11824 INSPIRATION DRIVE, EAGLE RIVER, AK 99577 Other Phone Number of Bedrooms Soil Rating Total depth f -.1. original grade 720-891-0377 4 Ft. LEGAL DESCRIPTION Depth to pipe invert from origi ]EXISTING jel depth beneath pipe Ft. Subdivision Block Lot MOUNTAIN MANOR 2 11 Fill added above or,!;?! Ft.IG !7�Z Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Dis en lines Ft. SEPARATION DISTANCES Toll Septic Absorption Holding Sewer T rption area Number of trenches Dist. between From Tank Field Lift Station Line Ft2 Well 1100,+ EXISTING 2b _r TANK 9 Septic E] S.T.E.P. 171 Holding 0 Other Manufacturer GREERTANK Capacity 1250 Gal. Surface Water *70'4- EXISTING NA Material HDPE PLASTIC Number of compartments 2 Lot Line 51+ EXISTING **10'+ OT��TION Foundation EXISTING Manufacturer Ca Gal. Remarks *WAIVER GRANTED (OSV201026) **NEW TANK IS 5+ FEET FROM ANY EXISTING DECK SUPPORT :Al!a:rm�location; �:*IEle'ctn ailed by PIPE MATERIAL House to tank D3034 (NE Tank to D3034 (NEW) W) drainfield Installer DEAN CONSTRUCTION Drainfield EXISTING CO/MTD3034 (NEW) Inspector JODY MAUS, GEG CONSULTANT BENCH MARK (Assumed elevation) 100.00 ft Inspection 1�1 6/25/2020 Location and description 2nd dates: BOTTOM OF SIDING BY FCO d ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's �tamp Conditional Approval: Date 41 D Septic System Approved &UM Date Note: this approval does not include well permit requirements. #AECC884 ro fe""00 UHovu5/u2/lu; . PERMIT NUMBER: RECORD DRAWING PARCEL NUMBER: OSP201181 050-6711 -12 MOUNTAIN MANOR; BLOCK 2, LOT IOA T\ fQ NSR EXISTING FCO i WITH HIGH LEVEL ALARM / NOTE: OLD SEPTIC TANK WAS COMPLETELY REMOVED AND DISPOSED :.(• �O/�,S // OFFSITE PER CONTRACTOR NEW 1250 GREER HDPE `^ / 2 -COMPARTMENT SEPTIC TANK y t�+,Sr WEST i y00Qoyc i _ ) WELL INSTALLED ti, G`sF L _ _ DOUBLE ry \ 1 GRAVEL.." CLEANOUTS (DBL1 & DBI -2) �� ` I " DRIVEWAY.." EXISTING DRAINFIELD \\ CEO f \ j FCO 5.5 1 20.7 \ j 70' WAIVER GRANTED TO ANY PORTION MH 20.1 22.4 \ OF SEPTIC SYSTEM. (WAIVER # OSV201026) STI 24.5 26.2 \\ i DBL1 26.3 27.9 \ DBI -2 26.8 28.5 C01 30.6 17.7r�- 0O2 56.4 33.1 MT1 1 56.6 33.5 APPROXIMATE LOCATION OF / O� OPEN CHANNEL WITH SURFACE WATER. BELIEVED TO BE SEASONAL. / (STILL FLOWING/PONDED ON 6/25/2020) / N r j rr ROADS END CIRCLE SALE: „1„= ao' Ltd ENGINEERING SALES CONSULTING , 3701 E TUDOR ROAD, SUITE 101 `ANCHORAGE, AK 99507 ” PHONE (907) 337-6179' FAX (907) 33&3246. WEBSITE: www.gammengineedng.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: JOSH INGRAM 720-891-0377 2 OF 3 PROJECT/LEGAL DESCRIPTION: DRAWN BY: MOUNTAIN MANOR SID; BLOCK 2, LOT 11 J.L.M. TYPE OF WORK: DATE: RECORD DRAWING OF SEPTIC TANK UPGRADE 6/26/2020 PERMIT NUMBER: RECORD DRAWING PARCEL NUMBER: OS P201181 050-6711 -12 TOP OF MH LID = 99.71 TOP OF TANK @ INLET = 93.68— INVERT OF BUNG @ INLET = 92.94 FINAL GRADE = 98.89-98.55 ►IST. NEW 1250 GALLON GREER HDPE SEPTIC TANK STI GARNESS ENGINEERING GROUP, Ltd ENGINEERING SALES CONSULTING 3701 E. TUDOR ROAD, SUITE 101 `ANCHORAGE, AK 99507' PHONE (907) 337-6179' FAX(907) 336-3246' WEBSITE: w .gamessengineering.corn PREPARED FOR: PHONE NUMBER: PAGE NUMBER: JOSH INGRAM 720-891-0377 3 OF 3 PROJECT/LEGAL DESCRIPTION: DRAWN BY: MOUNTAIN MANOR S/D; BLOCK 2, LOT 11 J.L.M. TYPE OF WORK: DATE: � RECORD DRAWING OF SEPTIC TANK UPGRADE 6/26/2020 TOP OF TANK @ OUTLET = 93.61 INVERT OF BUNG @ OUTLET = 92.82 Oft ..... ..... ........... ................... ,® ®f �':,• r .•..A. Ga ness..' 4u19 f® E- .1 Zai AV 40 '•; pROFess��`P: LICENSE ,,t1IlkIs � #AECC884 J TnWhom It May Concern: Precision Decks, LLC was hired tuevaluate the main structural support beam for the rear deck located at 11824 Inspiration Dr. The beam was determined to be out of compliance with the Municipality of Anchorage requirements for the span that existed. The inspection showed a Hem Fir #2 416 beam spanning adistance of21feet with nointermediate vertical supports. On July 2 nd , 2020 Precision Decks installed a 10" sono tube at a depth of 48 inches between the two posts with an outdoor treated lumber 46 vertical post, attached to the beam with Simpson hardware BC46Zandfastenedvyitheight1.2S^exteriorrutedposhivep|acementnaUs. . The placement ofthe sono tube was 7 feet from the east side support, shortening the largest span to less than 14 feet, allowing the beam tosupport acalculated load of50lbs per sqft. Precision Decks noted that the septic engineer requested no footings within a 7.5 foot radius of the new existing man -hole cover. The new sono tube was installed a distance of 9 feet from the cover and therefore should clearly be in compliance with the septic engineers request as well as the Municipality ofAnchorage's local minimum code requirements. Please feel free to contact Precision Decks with any further questions or concerns at (907)521-2126, m MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http,lfwww.muni.org/onsite Permit Number: OSP201181 Work Type: SepticTank Upgrade Tax Code Number: 05067112000 Site Legal Address: MOUNTAIN MANOR BLK 2 LT 11 G:0254 Site Mailing Address: 11824 INSPIRATION DR, Eagle River Owner: INGRAM JOSHUA N & LINDSEY A Design Engineer: GARNESS ENGINEERING GROUP LTD This permit is for the construction of: Effective Date Expiration Date Lot Size in Sq Ft Total Bedrooms: �t11�nC off. � Sn Department 6/19/2020 6/19/2021 57934 ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received B _ Date: Issued By: Date: d CI Municipality ®f Anchorage P.O. Box 196650 e 4700 Elmore Road Anchorage. Alaska 99519-6650 ® (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Department On -Site Water and Wastewater Section Department x x x x VARIANCE/WAIVED. REVIEW x x x x Waiver#: OSV201026 PID#: 050-671-12 COSA#:OSC201241 Permit#:OSP201181 Legal Description: Mountain Manor Block 2 Lot 11 Engineer: Garness Engineering Group Applicant: Josh & LindseV Ingram Your request for a waiver of the required 100 feet horizontal separation from the absorption field and septic tank to the surface water has been approved. The approved separation distance is 70.0 feet. See engineer's waiver request for justifications. This waiver approval applies to the existing absorption field and proposed septic tank only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. .............................................................................. 1 Waiver is Granted: X Waiver is not Granted: Date: C�l� l Ci ��i Approved by: Name of Reviewer *** VARIAN C E/WAIVER REVIEW **** UNICIPAILITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 .- On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTICM/ELL PERMIT APPLICATION Parcel I.D. 050-671-12 Property owner(s) JOSH & LINDSEY INGRAM Day phone 720-891-0377 Mailing address 11824 INSPIRATION DRIVE, EAGLE RIVER, AK 99577 Site address 11824 INSPIRATION DRIVE, EAGLE RIVER, AK 99577 Legal description (Sub'd., Block & Lot) MOUNTAIN MANOR S/D; BLOCK 2, LOT 11 Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) Q (w/wo ADU) Septic Tank 0 Upgrade 0 Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: NEW SEPTIC TANK TO SURFACE WATER (ALREADY REQUESTED WITH COSA) Distance: 70' I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: ��`J I ($--15 Waiver Fees: Date of Payment: ( a l okQ aD Date of Payment: Receipt Number: ()non 6 Receipt Number: Permit No. 65 8201 <? I Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201181, Rebecca Carroll, 06/19/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201181, Rebecca Carroll, 06/19/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSC201241, Rebecca Carroll, 06/19/20 Page 2 of 2 this surface water may be seasonal or intermittent. At the request of GEG, Tim Eklund performed a site visit on 6/4/20 to assess the situation. He determined that a surface water waiver was going to be required. We are requesting a 70 -foot (horizontal distance) waiver be granted for any portion of this septic system to the standing surface water. If the drainfield were to overflow, the daylighting wastewater would flow at least 80 feet along the ground surface, down a heavily vegetated slope, before reaching the surface water. To justify the waiver, a float was installed in the foundation cleanout that will activate an audible alarm in the residence if the liquid level in the septic or drainfield is more than 6 inches above the pipe invert elevation at the foundation cleanout. This will ensure the liquid level in the septic system will never get high enough to overflow any of the cleanout pipes and migrate towards the surface water without homeowner "notification". See the attached information and photos regarding the "alarm system". Drainfield to a Slope Greater than 25 Percent We did note the end of the sump for the drainfield is approximately 10 feet from a slope that is greater than 25 percent. We walked the area below the drainfield and did not find any indication of daylighting effluent. In short, it appears there is no concern with this existing condition. The system was installed prior to 1986 and we do not believe the code at that time required a separation distance to a slope greater than 25%. Deck Pile to Septic Tank: During our 2019 inspections we noted that there was a deck support with a pier block near or partially over the existing septic tank (see attached photo). The deck was constructed by a contractor retained by the current property owners. The property owner conveyed to us that the subject support was not necessary for structural integrity, so they had it removed. Attached is a recent photo with the deck support no longer present. GEG did not direct removal of the support or perform a structural evaluation regarding the deck and/or the necessity of the support that was removed. This concludes our findings. If you have any questions, please contact us at 337-6179 M 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www. garnessengineering.com Thank June 2, 2020 Mr. Jody Maus Garness Engineering Group Ltd 3701 E Tudor Rd # 101 Anchorage, AK 99507 Dear Mr. Maus, I am writing regarding the small amount of surface water observed during your trips to our property in May. To the best of our knowledge and recollection, this water is seasonal and only present during spring break-up when melting snow flows down the hill from Mount Baldy. Sincerely, Joshua Ingram Lindsey Ingram Home Owners 11824 Inspiration Dr, Eagle River, AK 99577 6a 5TD INS 0. x 4 . C 5:3 NINC I+29.1 pal as `, o ,EP's OCC e? 1 t !r tr f l r.0 1Fift B'E�u s / C —WELL W GRAVEL th e t 12.2 r,$i.A C RPORT z /1 S 1 yr f i 14 , '* 3 e 14-1 EASEMENTS ROADS END CIRCLE s AS BUILT SCALE i � 5�' ilk Project No. 11500 Daryl Avenue, Ancheara—3049 6 . (907) 522-6476 Phone 522-4625 aei rye kens langsas F jortath I hereby certify that I have surveyed the LOT 11, BLOCK 2, MOUNTAIN MANOR SUBDIVIS 3) 49LH*' Anchorage Recording District, Alaska, and th d therson are va within the ra lines and do not � ISI 1°i� �I�I �0�',°'�'' �� ��i � pr>Mspe eta, thatI� no Improvements ars the prcpert, hereto encroach are premises and that there or transrrslsslcan lines or rather vl lts easements on sold pr s Indicoted hereon. .d AT&T '" —," 8_;,46 -AM 98°!° I I V I I Cl kOV. MAUS > Alarm is in and works. Set just above crown of pipe. N Wn 0) DECK- cly Lot 10 Lu SEPTIC PIPES 60 0 C no 14 `,� - -�� 101V �b 6 3.0' CANT 4 01i)/t RETAINING WALL -WELL l$�l 7S0 1.0' COVERED DECK ABOVE wl 4.0'06.0' 'DECK BELOW jatC !-WELL GRAVEL.- 2.0' X24DRIVEWAY ) CANT .0. 12.2'x3l.4'q CARPORT ,�t4S Q Lot 11 57,934 s.f. ~Loi 100 10' DRAINAGE EASEMENTS ROADS END CIRCLE PLOT PLAN AS BUILT _�_ SCALE 1" = 50 GRID NW 254 Project No. 20%276 A1_ A 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang &r Associates, inc. (907) 522-6476 Phone (907) 522-4625 Fax 1=1 () F Professional Land Surveyors ken 0longsurvey.com X I Jonathan Otangsurvey.com A I hereby certify that I have surveyed the following described property: -'* 49TH* -,.-y LOT 11, BLOCK 2, MOUNTAIN MANOR SUBDIVISION (Plot No. 77-23) .. -I- -1i ......... Anchorage Recording District, Alaska, and that the improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that W I no Improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible G. LANIG) easements on sold property except as indicated hereon. LS -5202. Dated this the Day of of Anchorage, Alaska ......... 110 , It Is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plot. AECC963 MUNICIPALITY OF ANCHORAGE * M071 W" --v Ot.t Hey h and Environmental Prote on �EL�o.Jn Fourth Floor West 825 L Street Anchorage, Alaska 99501 279-2511, x 2.24, 225 INSPECTION EPORT ON-SITE SEWAGE DISPOSAL. SYSTEM a(� > NAMC. __M''nnnll``ING AUDRF55 d,./ LOC A"TION- -._. ____ _._d0/L .GnL_ uL �cltlhrlorJ__�� SEPTIC TANK: DISTANCE ¢ NU BER OF r� FROM WELL. __.__ M A N I J I ACTURE�xj5.L._� _-_ TE ILIAL _�% _. MPARTMENTSs ._- INSIDE. LENGTH_._._.' __-_ INSIDE WID111 _ LICIUID DFPI I _.."• LIQUID CAPACITY-,. __- ,ALLN�1 -ib O \ 250 A -S �2 R�c-,TPts -_ �ob.Q T�k-� rIRAIN FIFLCJ: � P6R-mi; �'�\�q\Z'1 %-7 TOTAL LENGTH DISTANCE FROM WELL 1ofl /._FOUNDATION /_�_. _-.m ARE cT LOT LINE_�� �._. _--OF LINE DISTANCE BETWELr- LINES _-. �17_.__-1RFNCH WIDTL; IN. TOTAL EFFECT i`/1 ABSORPTION nHLA .._d �v _ _-.. SO. (T. L CNGTH OF EACt I L INF_ - IAPI 101- I ILTL R H DEPT: TOP OF TILL TO FINISII GRADE _. _ _ MATERInI_ HINEATIi TILE 6_0__.IN. ABOVE TILE SEEPAGE PIT: DIAMETER _-.--OR WIDTH __ LL:NGIH__, DEPTH Log Crib Rings/,:RIB SIZE: UTAME.I[ 11 ____ULPIH_-__-DISTANCE FROM: WELLe____.�___. 101 AL EFFECTIVE BUILDING FOUNDATION______ NEAREST LOT L INE - ALSORPTION ARIA (WALL AREA) SQ. I T. ----_ . _-- -- -- -_ _---- - - -rte_ - � , _ Well Class Depth: � � f�0udlY�cR.'f' 0 II Well Distance To: Lot Line j 1 I Bldg: Sewer Line: Pipe M p �._ Pi aterials_: NI I � # of Bedrooms: i ++ Installer.— Remarks :- - I i I j I I - I I; ; 1)AIL nPPRovFD 0 Ft E GEO'. CHNI CAL Ft DEVEL -IMENT CO. Box 90, Davis St., Eagle River, Alaska 99577 694-2774 or 688-2280 Russell Oyster Earl Ellis 694-2774 SOIL LOG 6BB-2280 Soils Er Foundations Land Development Performed for: Name: s1".S`- Tel. No. t%`f= Mailing Address: Legal Description: Z&7-11, Depth (feet) Soil Characteristics 0 1 2 3 4 5 6 7 8 �� t7Ai4f ,✓ r%'✓11�/.:r�'?t r .S r_ C eS 9. 10 11� 15 16 Ground Water Encountered: Yes_. _ No ��4� If yes, what depth Proposed Installation: Seepage Pit Drain Field Comments: Performed by /�� V� ,E�� Date: UGHL ,.ry.U. SGS SW Id.. J Ysg9 1.33�1P tj "uciny . elktns of water pow how.wt .L_s1.`.. f� INVOKE Set Oump CQ1 WIWN DRILLING - 7 INVOICE N7 SR SOX 6M, ROOARp RD. PAU40k ALASKA "60 8 p YOUR P. O. NUM_ e&R TEWHONR 7454071 TERMS Lwi-L—BIk 2,_Sub LLdOf1t] WELL LOG"i far"° SALESMAN n _ ✓Jflrt l�. cJi to .... / c oi_.. e� <7��i DEPT CASIN FORMATION DEPTH IN I CABIN 146 166 167 Set PLEASE PAY FROM THIS INVOICE �j 7 7' L_.-�-ie!cl yn.0 9-S-Q�- 7✓� Ycl ., wP IS m;c 1�Vs2. _— ASSw.•��n9 L5 }ol w>;i� �: Usa. '.._...._ ... FORMATION ' R7 266 241 261 267 266 268 274 276 276 1,7-06 • 06 vv tont /hg <2 I nuze nvl �,c'.n l:e At,l j� _ I CABIN I FORMATION � eG • Municipality of Anchorage = On -Site Water and Wastewater Program (907) 343-7904 5 E T r Certificate of On -Site Systems Approval Parcel I.D. 050-671-12 1. GENERAL INFORMATION: Expiration Date: cd el alo'�'o Complete legal description MOUNTAIN MANOR S/D• BLOCK 2 LOT 11 Location (site address) 11824 INSPIRATION DRIVE, EAGLE RIVER, AK 99577 Current Property owner(s) JOSH & LINDSEY INGRAM Day phone 1-720-891-0377 Mailing address 11824 INSPIRATION DRIVE EAGLE RIVER AK 99577 Real Estate Agent KYRA DREHER W/ KELLER WILLIAMS Day phone 865-6500 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4- 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for:, V Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 55b— 412-0 Date of Payment (4 /it) i �® � Receipt Number o&aq C� COSA # C .261RLl Date: I : -70 Waiver Fee $ q&O — &7, • AD Date of Payment 12U 26 Receipt Number - Waiver # umberWaiver# COVID-j9 i DISCOUNT AppLII_Q-A 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness C In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend upon a variety of variables, including but not limited to, soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail to perform adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE •/ System #1 Approved for q bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for bedrooms, #AECC884 OcF (444f,,r Z`' ON-SITE o - with the f1lowi+ s�t�kCA : o- with o PROvthHtvl By: Original Certificate Date: 7 0200 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory COSA blue sheet 10-10-12.doc Nitrate Advisory Arsenic Advisory Other COSA Checklist Legal Description: MOUNTAIN MANOR; BLOCK 2LOT 11 Parcel ID: 050-671-12 If more than 1septic system onlot: CU8AChecklist # 1 of 1 Structure served bythis system 1 A. WELL DATA I EAST WELL/ WEST WELLI 110-1 Well is filed with Onsite (or attached) Well production edtime oftest Date drilled Water storage tank volume `,vv gallons Total depth Well disinfected for coliform test? E] Yes F011 No Cased to ��Coliform bacteria ioNegative IRE Sanitary seal is functioning correctly Nitrate -819/100mg/L [l Nitrate less than MRL (ND) ��wires are properly protected Arsenic FOR BOTH ug/L FE-1Arsenic less than MRL(ND) Casing height (above ground) 18~n8+ in. Collected by GEG.LT[l' Date offlow test for COSA Date ofSample 5/26/20Stotinwater|eve|etbeginningofteot Comments *PER SULLIVAN WATER WELL INSPECTION. SEE ATTACHED REPORT. —ESTIMATED TANK SIZE BASED UPON o/wswomwoopTANK. GEG, LTD. DID NOT EVALUATE THE WATER STORAGE SYSTEM. ***PER GEG FLOW TEST. B. TANK DATA T STATIONT STATION Age oftank(s) NEW years [l Require aintenance Tenkb/po/mebahm| *opEof sAge of lift station Measured operating fluid level inseptic tank NEVV Lift station materia F01Standpipes/foundation o|aonoutpernsuovddnywing Commen Oahe of pumping NEW Q. ABSORPTION FIELD DATA DEEP TRENCH Which system tested (date installed) 03/77 ��ALL standpipes present per record drawing Total measured depth from grade 9-75*(nax Measured depth topipe invert from grade 5J5* FlN/A — pressurized field FlMonitor tubes gohobottom ofeffective. |fnot, state depth into effective *4LFEET 5115/19�e������___ RoouUo R]Paoo For 4 bedrooms Fluid depth prior hotest �» in New depth 0 in Elapsed time 0 min ��Code-required soil cover over field Final fluid depth u in 171System presoaked . Absorption rate 800+ gpd (Required ifvacant for greater than 3Odays prior hm Any rejuvenation treatment (past 13months) NONE date oftest) ��— Gallons introduced gaUona |fyee.on�erdate Comments/Deficiencies: *EFFECTIVE DEPTH ON 1977 INSPECTION REPORT SHOWS 5 FEEET (60") OF EFFECTIVE *MONITORING TUBE IN DRAINFIEDL FOUND TO BE DRY ON 5126/2020. COSA Checklist yellow sheet �� E SEPARATION DISTANCES From Private Well onLot to: (Please enter distances if less than required mif community well) Septic Tank/Lift Station onLot >1OU' Yes if No Community Sewer Manhole/Cleanout >1OO' r.11 Yes ifNo# Property Line >5' MYea ifNoft Neighboring Tank >1OO' ��Yeo ifNoft Surface Water >1DU' El Yes if No **70+ ft Private Sewer/Septic Line >�25'E]Yes ifNoft Absorption Field onLot >1UU' MYea ifNoft Private Wells >1OO' Holding Tank >1OU' R] Yes ifNoft Neighboring Absorption Fields >1OO' ifNoft Animal Containment >5O' El Yes ifNnft Yes ifNuft ifNoft \fseptic tank iaunder driveway comment below /certify that / have determined through field inspections Manure/Animal Excreta Storage >10O' Community Sewer Main >7S' Yes ifNoft ��Yeo ifNoft From Septic/Holding Tank mnLot to: (Please enter distances if less than required) Building Foundations >1O' Yes if No + ft Surface VVaber>1OO' Yes ifNo*7D+ft Property Line >5' Yee ifNoft Community Wells >28O' Wells onAdjacent Lots: Surface Water >1DU' El Yes if No **70+ ft Absorption Field >5' Yes ifNoft Private Wells >1OO' Yea ifNnft Water Main >10' Yeo ifNoft Community Wells >2UO' Yea ifNoft Water Service Line >1O' Yes ifNoft \fseptic tank iaunder driveway comment below From Absorption Field onLot to: (Please enter distances if less than required) Building Foundation >1O' ED Yes ifNnft Ifabsorption field isunder driveway comment below Property Line >1O' G/1 Yes ifNnft Wells onAdjacent Lots: Water Main >1O' [Z] Yes ifNoft Private Wells >1DO' Yeo ifNoft Water Service Line >1O' MV Yes ifNoft Community Wells >28O' Yeo ifNoft Surface Water >1DU' El Yes if No **70+ ft F. ENGINEER'S COMMENTS *10'+ TO HOUSE FOUNDATION AND 5'f TO PILES FOR DECK. ^*MSV201026 G. ENGINEER'S CERTIFICATION /certify that / have determined through field inspections and review ofMunicipal records that the above systems are /nconformance with MOA COS4guidelines /neffect onthis date. SOGxChecklist yellow sheet o«scouo* 11 MUNICIPALITY OF ANCHORAGE    DEVELOPMENT SERVICES DEPARTMENT    907‐343‐7904  On‐Site Water and Wastewater Section                                                                                           Fax: 343‐7997  www.muni.org/onsite         Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519‐6650 * www.muni.org      Nitrate Advisory   Certificate of On‐Site Systems Approval # OSC201241  Subdivision: Mountain Manor, Block: 2, Lot: 11  A water sample revealed a nitrate concentration of 8.2 & 10.0 milligrams per liter  (mg/L).  The Environmental Protection Agency (EPA) has established a maximum  contaminant level (MCL) of 10.0 mg/L for public drinking water systems.  While  private wells are not subject to this regulation, EPA standards are based on existing  health information and can therefore be used to gauge the relative quality of water  from private wells.  Since nitrates are known to slowly increase, we recommend  you monitor the water quality.  Please see the attached “Nitrate Fact Sheet” for  important information regarding nitrate.  This advisory must be attached to all copies of the subject Certificate of On‐Site  Systems Approval.                                 Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519‐6650 * www.muni.org  Nitrate Fact Sheet  From Northern Testing Laboratories, Inc.  Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water.  Nitrate  is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells.  SOURCE:  Nitrate is a major component of fertilizer and wastewater.  Often the nitrate is in the form of  ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the  oxidized form known as nitrate.  Sources of nitrate from wastewater include urea, ammonia cleaners,  food solids, and bacterial cells.  It may also result from the breakdown of organic matter buried in the soil.  TOXICITY:  Nitrate is generally not toxic to adults or children over the age of two or three years, but is  associated with a potentially fatal infant disease called methemoglobinemia.  In the digestive system of  young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood  stream.  There it combines with the hemoglobin and interferes with the ability of the blood to carry  oxygen.  For this reason, methemoglobinemia is referred to as “blue baby” disease.  The EPA limits the  concentration of nitrate in public drinking water supplies to 10 mg/L.  The standard has been lowered  from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization.  TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home  water treatment systems such as softening or iron filtration does not readily remove nitrate.  The best  method for limiting nitrate in well water is source control.  This can include avoiding overdosing of  fertilizer near the well and maintaining good separation distances between septic tank leach fields and  the well.  A special anion exchange filter that contains a medi a with a strong affinity for negatively charged  ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate.  TESTING:  Nitrate analysis is usually done by one of the several  “wet  chemical”  methods  using  a  spectrophotometer to read the final color endpoint.  Specific ion electrodes also can be used to detect  the activity of nitrate in water.  This laboratory uses several different wet chemical methods approved  under the public water supply laboratory certification program.  They also have test kits available, which  the laboratory uses to perform an inexpensive “screening test”, and with which the homeowner can  monitor the change in nitrate levels from their well.  They recommend comparing the test kit results  against a certified analysis from the lab occasionally to verify the accuracy of the kit.  We recommend  using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples.          SGS Ref.# 1202110002 Client Name Garness Engineering Group, Ltd (GEG) Printed Date/Time 06/03/2020 16:59 Project Mame/# MOUNTAIN MANOR BLOCK 2, LOT 11 Collected Date/Time 05/26/2020 11:23 Client Sample IOD WEST WELL Received Date/Time 05/26/2020 13:22 Matrix Drinking Water Technical Director Stephen C. Ede Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Arsenic ND 5.00 ueL EP200.8 B (<10) 06/01/20 06/03/20 ACF Waters Department 'Total Nitrate/Nitrite-N 10.0 0.400 mg/L SM21 450ONO3-F C (<10) 06/02/20 EWW Microbiology Laboratory E. Coli Negative 1 100mL SM21 9223B A 05/26/20 MA Total Coliform Negative 1 100mL SN121 9223B A 05/26/20 M.A SGS SGS Ref.# 1202110001 Client Name Garness Engineering Group, Ltd (GEG) Project Name/h! MOUNTAIN MANOR BLOCK 2, LOT 1 I Client Sample ID EAST WELL Matrix Drinking Water Printed Date/Time Collected Date/Time Received Dateffirne Technical Director 06/03/2020 16:59 05/26/2020 11:17 05/26/2020 13:22 Stephen C. Ede Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container 1D Limits Date Date lnit Metals by ICP/MS Arsenic ND 5.00 ug/L EP200.8 B (<10) 06/01/20 06/03/20 ACF Waters Departutent Total Nitrate/Nitrite-N 8.19 0.200 mg/L SM21 450ONO3-F C (<10) 06/02/20 EWW Microbiology Laboratory E. Coli Negative I 100mL SM21 9223B A 05/26/20 M.A Total Coliform Negative 1 100mL SM21 9223B A 05/26/20 M.A Carroll, Rebecca M. From: Jody Maus <Jody@garnessengineering.com> Sent: Tuesday, July 7, 2020 5:15 PM To: Carroll, Rebecca M. Cc: Jeff Garness Subject: Mountain Manor wells Becca, Based upon my site visit to take the most recent water sample, both wells were active and being used to supply water to the house. Sincerely, Jody Maus Garness Engineering Group, LTD 907-223-0555 Sent from my Whone 1 Municipality of Anchorage On -Site Water & Wastewater Program (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 050-671-12 Expiration Date: 1. GENERAL INFORMATION Complete legal description MOUNTAIN MANOR S/D BLOCK 2 LOT 11 Location (site address) Current Property owner(s) Mailing address Real Estate Agent 11824 INSPIRATION DRIVE, EAGLE RIVER, AK, 99577 MICHAEL LUPRO & MARCIA BRAD Day phone 11824 INSPIRATION DRIVE EAGLE RIVER, AK, 99577 SHAWN RABBIT W/ KELLER WILLIAMS Day phone 2. TYPE OF DWELLING: Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: 227-7687 441-2500 TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site 0 Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ W aiver/Variance request for: r Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 4� Date of Payment /*� Receipt Number ��S �> COSA # C2, Date: Waiver Fee $ Date of Payment Receipt Number Waiver # Distance: — 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. i further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK, 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: in conducting this evaluation, GEG, UD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils cm chfron, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever 6. DSD SIGNATURE System #1 Approved for H bedrooms. System #2 Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following Phone 337-6179 Date ill% Original Certificate Date: C —73531 Pr o fessio�o� (of ANCti�,,��i/ ON-SITE �� WATER AidD WASTEWATER rot The V nlcipality or Anchorage Develop, emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other (Rov 1 Vnfi1 If more than 1 septic system is on the lot: COSA Checklist # _of_ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: MOUNTAIN MANOR; BLOCK 2, LOT 11 Parcel ID: 050-671-12 A. WELL DATA *PER SULLIVAN WATER WELLS INSPECTION. SEE ATTACHED. EAST WELL WEST WELL Well type PRIVATE If A, B, or C provide PWSID# N/A Date completed UNK/ 7/25/80 Sanitary seal (Y/N)YES YES *BEDROCK/ Total depth*105+ 377 ft. Cased to *BEDROCK ft. FROM WELL LOG Date of test NO WELL LOG/7/25/80 Static water level UNK/UNK ft. Well production UNK/1.33 g.p,m, WATER SAMPLE RESULTS: Coliform 0/0 colonies/100 ml. Arsenic: ND NDug./L. B. SEPTIC/HOLDING TANK DATA Well Log (YIN) NO/YES Wires properly protected (Y/N) YES YES Casing height (above ground) 12+/12+ in. AT INSPECTION **10/25/13 12/13 ft, 1.78/5.54 g.p.m. **WELL TESTS PERFORMED BY SULLIVAN WATER WELLS 5.87/ Nitrate 6.11 mg./L. Collected by: SULLIVAN WATER WELLS Date of sample: 10/25/13 Tank Type/Material SEPTIC/FIBERGLASS Date installed 8/3/77 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Date of pumping 10/10/2013 Pumper JR'S PUMPING C. ABSORPTION FIELD DATA Date installed 8/3/77 Soil rating (g.p.d./ft2or /bdrm 85 System type TRENCH Length 35 ft. Width 3 ft. Gravel below pipe 5 ft. Total depth *8.00 ft. Eff. absorption area 350 ft' Monitoring tube YES Depression over field NO Date of adequacy test 10/29/13 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 0 in. Water added 604 gal. New depth 0 in. Elapsed Time: E min. Final fluid depth 0 in. Absorption rate >= 600+ g,p,d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE If yes, give date — D. LIFT STATION Date installed - "Pump on" level at in. Size in gallons - Manhole/Access (Y/N "Pump off" level High water alarm level at in. Cycles tested Meets alarm & circuit requirements? E°: SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+/100'+ Absorption field on lot 100'+/100'+ Public sewer main N/A On adjacent lots 100'+/100'+ On adjacent lots 100'+/100'+ Public sewer manhole/cleanout N/A Sewer /septic service line 25 +/25 + Holding tank N/A Animal containment areas 50'+/50'+ Manure/animal excrete storage areas 100'+/100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS " Date i �7.�/14- (Rev. 11/05) Municipality of Anchorage Community Development Department <a a.: Development Services Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Nitrate Advisory Certificate of On -Site Systems Approval # OSC131604 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block 2, Lot 11 of Mountain Manor subdivision. This inspection revealed a nitrate concentration of 5.87/6.11 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On - Sits Systems Approval. YET C. JG p.omn no's ,, i AS -BUILT I hereby certify that I have surveyed the following described property: F, . x Anchorage Recording Precinct, Alaska, and that the unprove menta situated thereon are within the pro art lines and do overlap or encroach on the property 1 docent thereto. encroach no improvements on property ymg 1 on the premises m question and that there are no roadways, I hansmissmn lines or other visible easements on said property except as indicated hereon. Dated at Eagle River, Alaska n i j this 3.:= day of —O ' HNSON l� ROBERT c. JOHNSON SCALE: Regrstered Land Surveyor No. NG -LS Box 77-0456, Eagle River, Alaska 99577 Phone (907) 694-LM3 ULLIVAN MATER WELLS "` 0'r P.O. Box 670269, Chugiak, Ait 99567 907-688-2759 TO: Lindsey Ingram 11824 Inspiration Drive Eagle River, AK 99577 TERMS: PHONE 720-233-4242 DATE OF ORDER 11-25-13 ORDER TAKEN BY CUSTOMER ORDER NO. ❑ DAY WORK ❑ CONTRACT ❑ EXTRA JOB NAME/NUMBER JOB LOCATION 11824 Inspiration Dr. JOB PHONE STARTING DATE 11-25-13 CITY. DESCRIPTION OF WORK PRICE AMOUNT 2 Camera wells Close Well: L vo i 15' of casing 15' to 17' borehole is smooth 17' to 65' borehole is rough and fractured 18' to 20' water seeping 20' to 30' water seeping increases 103' water spraying in 105' water spraying in Far Well: �, s 20' of casing 21' to 22' water pouring in 21' to 100' borehole is rough and fractured Unable to determine where water is coming from below 22' due to cascading water. Thank you, Cole Sullivan DAIE 1125-13 COMPLETED: WORK ORDERED BY: \� ' SIGNATURE I HEREBY ACKNOWLEDGE THE SATrSEACTORY COMPLETION Oc-ME ABOVE DESCRIBED WORK. p DO - CO dba `' , ULL[UANVWATER QUELLS O,rP.O. Box 670269, Chugiak, AK 99567 907-688-2759 TO: Lindsay Ingram PHONE 720-233-4242 DATE OF ORDER 10/25/2013 ORDER TAKEN BY CUSTOMER ORDER N0. 0 DAY WORK 0 CONTRACT 0 EXTRA JOB NAME/NUMBER JOB LOCATION -- -117814, nspi ration Drive ar well- farthest from house„L_,,.: j JOB PHONE STARTING DATE TERMS: WORK ORDERED BY: SIGNATURE _nrvvavLtuvt I ntM l ISFACTORY COMPLETION OF THE ABOVE DESCRIBED WORK. p DOC DO dba OLE ' ULLIVAN WATER WELLS P.O. Box 676269, Chugsak, AK 99567 907-988-2759 TO: Lindsay Ingram TERMS:��✓ i WORK ORDERED BY: SIGNATURE I HEREBY ACKNOWLEDGE THE SATISFACTORY COIVPLETION OF THE ABOVE DESCRIBED WORK, Sewer and drain Anchorage: (90h 575-9915 SGS Ref.# 1135505001 Client Name Sullivan Water Wells Project Name/# 11824 Inspiration Dr. Eagle R Client Sample ID 11824 Inspiration Dr. Eagle R Matrix Drinking Water Microbiology Laboratory CDE Sample Remarks: / Parameter Results LOQ Metals by ICP/MS 11/06/2013 11:00 Arsenic ND 5.00 Waters Department Stephen C. Ede Total N itrate/Nin ite-N 5.87 0.100 Microbiology Laboratory CDE E. Coli Negative I Total Coliform Negative I Printed Date/Time 11/14/2013 14:56 Collected Date/Time 11/06/2013 11:00 Received Date/Time 11/06/2013 14:38 Technical Director Stephen C. Ede Allowable Prep Analysis Units Method Container ID Limits Date Date [nit ug/L EP200.8 C (<10) 11/08/13 11/12/13 HKS mg/L SM21450ONO3-F B (<10) 11/12/13 CDE 100mL SM219223B A I00mL SM219223B A 11/06/13 SDP 11/06/13 SDP SCS Ref.# 1135504001 Client Name Sullivan Water Wells Project Name/# 11824 Inspiration Dr. Eagle R Client Sample ID 11824 Inspiration Dr. Eagle R Matrix Drinking Water 11/12/13 CDE Sample Remarks: Printed Date/Time 11/14/2013 14:55 Collected Date/Time 11/06/2013 10:30 Received Date/Time 11/06/2013 14:38 Technical Director Stephen C. Ede Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Arsenic ND 5.00 Waters Department "Total Nitrate/Nitrite-N 6.11 0.100 Microbiology Laboratory E. Coli Negative 1 Total Coliform Negative 1 ug/L EP200.8 C (<10) 11/08/13 11/12/13 HKS mg/1- SM21450ONO3-F B (<10) 11/12/13 CDE 100mL SM219223B A 100mL SM219223B A 11/06/13 SDP 11/06/13 SDP N S. LEGAL DESCRIPTION DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE 1 Im [:1 One F-1Four❑ Other ( INSPECTOR INSPECTOR INSPECTOR MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTI DEPT. OF 1i`J i l i'< 825 L Street - Anchorage, Alaska 99501 ENVIRONiME L .'- i. _: i `CTION • ENVIRONMENTAL SANITATION DIVISION MAR T u 1980 Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWEIRFBQEt f D DIRECTIONS; Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten 00) days for processing. 1. PROPERyYOWNER PHONE- X INDIVIDUAL/ON-SITE** MAILING, j�ADDRESS Oie4`i 61 PROPERTY RESIDENT (If differentfrom above) PHONE NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. )2119 2. BUYER PHONE C MAILING ADDRESS ? 7 r e4p G; 3. LENDING INSTIT TION PHONE Lew MAILIN DDRESSSS .. 4. REACTOR/AG NT 411 PHONE MAILING ADDRES / N S. LEGAL DESCRIPTION cv, STREET LOCATION 6. TYPE OF RESIDENCE NUMBER OF,BEDROOMS [:1 One F-1Four❑ Other SINGLE FAMILY ❑ Two ❑ Five ❑ MULTIPLE FAMILY J Three ❑ 'Six 7. WATER SUPPLY INDIVIDUAL* * ATTACH WELL LOG. A well log is required for all wells drilled ❑ COMMUNITY since June 1975. For wells drilled prior to that date, give well ❑ PUBLIC UTILITY depth (attach log if available.) B. SEWAGE DISPOSAL SYSTEM X INDIVIDUAL/ON-SITE** I�l`1 1 YEAR ON-SITE SYSTEM WAS INSTALLED. ❑ PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 (Rev. 6/79) # 1. _ .1.% ty nr_ 1. TYPE OF RESIDENCE ❑ SINGLE FAMILY ❑ MULTIPLE FAMILY THIS SIDE FOR OFFICIAL USE ONLY NUMBER OF BEDROOMS ❑ ONE ❑ THREE ❑ FIVE ❑ OTHER ❑ TWO ❑ FOUR ❑ SIX 2. WATER SUPPLY' ❑ INDIVIDUAL ❑ COMMUNITY ❑ PUBLIC UTILITY Connection Verified PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM ❑INDIVIDUAL/ON-SITE ❑PUBLIC UTILITY Connection Verified PERMIT NUMBER DATEINSTALLED INSTALLER ❑Septic^T�acnk or ❑ Holding Tank Sizer Tank is homemade give dimensions: SOILS RATING TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA 4.. DISTANCES WELL TO: MATERIAL Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS &—APPROVED FOR �_ BEDROOMS ❑ CONDITIONAL APPROVAL (letter must as ❑ DISAPPROVED DATE BY 19_nin (Rev. 6/79) ficate)