HomeMy WebLinkAboutMOUNTAINSIDE VILLAGE BLK 2 LT 3Mountainside Vi'811age Block 2 Lot 3 #020-172-11 Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP231208 PID Number: 020-172-11 Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ® Upgrade Name MICHELLE TURNER & CARL JOHNSON ABSORPTION FIELD - EXISTING ❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 17800 STEAMBOAT DRIVE, ANCHORAGE ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot MOUNTAINSIDE VILLAGE 2 3 Fill added above original grade Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ft' Ft. Well 100'+ -- 25'+ TANK ® Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer GREER Capacity 1500 Gal. surface water 100'+ -- Material HDPE Number of compartments 2 Lot Line 10'+ __ NA Foundation 10'+ LIFT STATION Manufacturer Capacity Gal. Remarks Alarm location Electrical installed by Installer JRS PIPE MATERIAL House to tank 3034Tank to 3034 drainfield Drainfield CO/MT 3034 Inspector FWCS BENCH MARK (Assumed elevation) 100 ft Inspection 1' 9/1/23 2nd 9/1/23 Location and description 3rd 4th TOP OF MH ON-SITE WATER AND WASTEWATER SECTION APPROVAL :41�k Conditional Approval: Date ��TI . •Z__ �Septic Curtis Huffman • , Syste Approve Ynt CE128991Dat•9/5123 • ���Note: this approval does not include well permit require 1SS\0 7 UDNL/l0) PID:020-172-11 PERMIT:OSP231208 FIRST WATER CONSULTING MOUNTAINSIDE VILLAGE B2, L3 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP231208 Work Type: SepticTank Upgrade Tax Code Number: 02017211000 Site Legal Address: MOUNTAINSIDE VILLAGE BLK 2 LT 3 G:3439 Site Mailing Address: 17800 STEAMBOAT DR, Anchorage Owner: TURNER MICHELLE T & Design Engineer: FIRST WATER CONSULTING This permit is for the construction of: Effective Date: Expiration Date: i�1 an t �0 roc .,;: P S` U r. O Department Lot Size in Sq Ft: Total Bedrooms: 8/14/2023 8/13/2024 55000 ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: S �� D 7-0 LJ C, Issued By: Date: Date: `7 2t i 3 . E MUH CO P'\'LIITY 0 /\ HCH0�i� GL: Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 02 0-172-11 Property owner(s) Carl Johnson & Michelle Turner Day phone Mailing address 17800 Steamboat Drive Anchorage, Alaska 99516 Site address 17800 Steamboat Drive Anchorage, Alaska 99516 Legal description (Sub'd., Block & Lot) Mountainside Village Block 2 Lot 3 Legal description (Township, Range & Section) Lot Size 55,000 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) Septic Tank Q Upgrade Q (w/wo ADU) Holding Tank ElRenewal ElDuplex (D) El ❑ Multiple Dwellings E]Privy (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Z — Waiver Fees: / f >Z-3Date of Payment: Date of Payment: Receipt Number: Receipt Number: Permit No. IWO Waiver No. G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / firstwaterAK@gmail.com ! !! July 25, 2023 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: SEPTIC TANK UPGRADE PERMIT LEGAL: MOUNTAINSIDE VILLAGE BLOCK 2, LOT 3 The owner has requested that we obtain a septic permit to upgrade the existing aged steel septic tank on the above referenced lot. We propose to install a 1500-gallon HDPE tank per the attached design to serve the existing 4-bedroom residence. The 1500-gallon HDPE tank to be installed allows for future consideration or flexibility. No groundwater was noted in the MOA on-site file, but if groundwater is encountered during installation an epoxy coated steel septic tank may be required. The lot and area are served by private water. The design will not impact any of the neighboring properties. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231208, Curtis Townsend, 08/14/23 FIRST WATER CONSULTING NO WELLS WITHIN 100' OF PROPOSED SEPTIC TANK MOUNTAINSIDE VILLAGE B2, L3 DESIGN DETAILS: Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231208, Curtis Townsend, 08/14/23 10' UTILITY EASEMENTS li Lot 3 Lot 4 Lot 3 55,000 S.F. A� I ar f i 1 , 48.2' O- 1 4.0.'x14.5' MANHOLE` BALCONY- A WELL SEPTIC PIPES FIRE PIT / S I l ' WIRE FENCE 6' 1 30.0' I I I I � S 00'49'00"E 15.40' \ �rn '( 4 00 11 0o o j v f a 1 � ` r / 44 h 16.3'x24.3' 2 STORY GALLERY S 11'22'00"E 3.5'x8.1' DECK 39.01`' � 1 1 10' UTILITY EASEMENTS Lot 4 Lot 2 I \ I I PLOT PLAN=_ AS BUILT_ _X SCALE _1 5' _ GRID _ SW 3439Project No. 23=45Z/A1 __ 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates, inc. (907) 522-6476 Phone kenOlangsurvey.com Professional Land Surveyor s jonothanOlangsurvey.com .s OF AL kl travisOlongsurvey.com P'��! ' ' ' • -1 I hereby certify that I have surveyed the following described property: LOT 3, BLOCK 2, MOUNTAINSIDE VILLAGE SUBDIVISION (PLAT No. 79-177) Anchorage Recording District, Alaska, and that the improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated this the __'_'= Day oft'"t�4r�__,_'?`___, at Anchorage, Alaska It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. r > !Gj •' 48TH •9 I *. .* KENNETH G. LANG 0 5242 i ll P QFf5514N���•�� State of Alaska AECC963 ►�o�.n..kalt-,,sib U; l�ao�e �3- a L- 3 AAAROW PUMP & WEA[ SERVICE, LLC UHOMO U(CIE P.O. Box 110496 Anchorage, AK 99511 NO. 9486 Office: (907) 346-9355 • Fax (907) 333.8976 Eagle River: (907) 622-9335 CUSTOMER _ r`/i/vG �/✓ice✓ _ _'''�K.--- L JOB SITTE,! —I INVOICE GATE l /1 / WELL OEPTIIeWL -� f CHI-CMNATED PUMP DEPTH / SALESPERSON QU NTITY DESCRIPTION PRICE ;' < i'=C_-7z/fin_. -j�AMOUNT —yam ✓ _.Jt`L7. L�'?J..: S'L �4�J_��`!/C.C�_a-.> �./ Es/ (G - �_J� __ _'_`_`_.. � �._ -- _ {/ > S ; � S �e /r,� . 1"a« r r✓��i cam- LABOR HOURS RATE AMOUNT TOTAL MATERIAL TOTAL LABOR WORK ORDERED BY DATE COMP. TOTAL LABOR PAY THIS AMOUNT 3Z o Thank You SIGNATURE (1 Hereby Acknowledge the Satisfactory Completion of the Above Described Work and agree that if above work is not paid for in 90 days I agree to allow Aarow Pump & Well Service, L.L.C. the right to remove unpaid for equipment and charge for labor already performed & labor to remove unpaid for equipment) TERMS: ACCOUNTS PAYABLE AT 10TH OF MONTH FOLLOWING PURCHASE. SERVICE CHARGE AT RATE OF 1.5% PER MONTH WILL BE CHARGED ON OVERDUE ACCOUNTS. MUNICIPALITY OF ANCHORAGE ® DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION \\ 82.5 LStreet - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND WELL INSPECTION REPORT NAME PHONE NEW _ L� %>•-]C�'i�?..=�"��1 1-C.-r11._t2C._ ---- ------ ----- �96 e ❑ UPGRADE MAILING ADDRESS '� ~ V r� q W �5 - LEGAL DESCRIPTION � l LOCATION NO. OF 6EDROOMS J' DISTANCE TO: Well Absorption_zrea p, i� �' Dwelling / JV &L1 PERMIT NO. 810 riq h Z Manufacturer MaterialC No. of compartments Li rapacity in gallons IF HOMEMADE: Inside length Width Liquid depth L O 0 z DIS E TO: Well e lint' PERMIT NO. -__-- 2 O E Q anufacturei erial Liqu aVacity In gallons Well DISTANCE TO: ��yr Found atign Nearest lot line A1�7- f�� PERMIT NO. 'R- 1`0 O �� No. of lines Vim each line LJ��{7_ _ Total length o lines Trench width �–inches Distance between lines -/ Top of the to finish gradde Material beneat the e.yL n e Total effective ab oiption ar n W Length Width Depth PERMIT NO. – Q Ip Type of crib – Crib diameter Crib de Total effective a ption area 0. a W — W N DISTANCE TO: Well Building foundation N t lot line J Class Z Depth Driller Distance to lot line PERMIT NO. J 7 r lij _ W DISTANCE TO: Building foundation Sewer line Septic tank _ Absorption area (s) – OTHER nM. C) PIPE MATERIALS G "o � ry `7 - � d 0 r° SOIL TEST RATING V INSTALLER //++ �r47fw�U- REMARKS 1 — 101 I _ APPROVEDDATE y� �C4yl �jLEGAL TYPE OF SOIL HRPTION SYSTEM ITRENCH MHXIMUM NUMBER OF BEDROOMS � 4 SOIL RHTING (SQ 225 THE REQUIRED SIZE OF THE SOIL IRB SORPTION SYSTEM IS� �Q���� �� ��������� � THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRHINFlELD� THE DEPTH OF R TRENCH OR PIT IS THE DISTHNCE BETWEEN THE SURFHCE OF THE GROUND HND THE BOTTOM OF THE EXCHVHTION (I.1 FEET) THERE IS NO SET WIDTH FOR TRENCHES. THE GRHYEL DEPTH IS THE MlNIMUM DEPTH OF OUTFALL PIPE HND THE BOTTOM OF THE EXCHVHTION (IN FEET) A �.... ���� PERMIT HPPLICHNT HHS THE RESPONSIBILITY TO INFORM THIS DEPHRTMENT DURING THE INSTHLLHTION INSPECTIONS OF MAY WELLS HDJHCENT TO THIS PROPERTY HND THE NUMBER OF RESIDENCES THHT THE WELL WILL SERVE. fl:::')I P -A ��R.- F, E 1C. If-"' F. ��^~ BHCKFILLING OF HNY SYSTEM WITHOUT FINHL INSPECTION HND HPPROVHL GY THIS DEPHRTMENT NILL BE SUBJ�CT TO PROSECUTION. MINIMUM DISTHNCE BETWEEN H WELL HND HNY �N~SITE SEWHGE DI�POSHL SYSTEM IS 100 FEET FOR H PRIVHTE WELL OR 150 TO 200 FEET FROM H PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL MINIMUM DISTHNCE FROM 8 PRlVHTE WELL TO H PRIVHTE SENER LINE IS 25 FEET HND TO HCOMMUNITYR�SEWERELINEDISU75 FEET|TURNED TO THE DEpHRTMENT WITHIN ]0 DHYS WELL LOGS M�� �UIx u OF THE HELL COMPLETION OTHER REQUIREMENTS MAY HPPLY. SPECIFICHTIONS HND CONSTPUCTION DIHGRHMS HRE HVHILHBLE TO INSURE PROPER INSTAt- LHTION- W K IT: 1-1 X - V FEE Fo, Y 0, �E�E �'-1 F..", LH.. E.-,3 AL I CERTIFY THAT 1� I HM FHMILIHR WITH THE REQUIREMENTS FOR Or-4--S-IFF:SEWERS HND WELLS HS SET FORTH BY THE MUNICIPHLITY OF HNCHORHGE 2 I WILL INSTALL THE SYSTEM IN HCCORDHNCE WITH THE CODES. ]` I UNDERSTHND THRT THE ON�SITE SE�ER SYSTE� MHY REQUIRE ENLHRGEMENT IF THE R SIDENCE IS REMODELED TO INCLUDE MORE THAN 4 BEDROOMS HPPLICHNT JHMES HITCHCOCK / DHTE ISSUED BY�L������������ DEPHRTME/�/ / M� � ^ ENVIRONMENTHi ,�OTECTION /M STREET/ fill CHORHGE, 264~4720 :'I������ HPPLICHNT JHMES HITCHCOC PHLMER 99645 ]76~5�59 LOCHTION STEHMBOHT DR � LOT SIZE 55000 SQUHRE FEE.T LEGHL L] B2 MOUNTHIN SIDE VILLHGE TYPE OF SOIL HRPTION SYSTEM ITRENCH MHXIMUM NUMBER OF BEDROOMS � 4 SOIL RHTING (SQ 225 THE REQUIRED SIZE OF THE SOIL IRB SORPTION SYSTEM IS� �Q���� �� ��������� � THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRHINFlELD� THE DEPTH OF R TRENCH OR PIT IS THE DISTHNCE BETWEEN THE SURFHCE OF THE GROUND HND THE BOTTOM OF THE EXCHVHTION (I.1 FEET) THERE IS NO SET WIDTH FOR TRENCHES. THE GRHYEL DEPTH IS THE MlNIMUM DEPTH OF OUTFALL PIPE HND THE BOTTOM OF THE EXCHVHTION (IN FEET) A �.... ���� PERMIT HPPLICHNT HHS THE RESPONSIBILITY TO INFORM THIS DEPHRTMENT DURING THE INSTHLLHTION INSPECTIONS OF MAY WELLS HDJHCENT TO THIS PROPERTY HND THE NUMBER OF RESIDENCES THHT THE WELL WILL SERVE. fl:::')I P -A ��R.- F, E 1C. If-"' F. ��^~ BHCKFILLING OF HNY SYSTEM WITHOUT FINHL INSPECTION HND HPPROVHL GY THIS DEPHRTMENT NILL BE SUBJ�CT TO PROSECUTION. MINIMUM DISTHNCE BETWEEN H WELL HND HNY �N~SITE SEWHGE DI�POSHL SYSTEM IS 100 FEET FOR H PRIVHTE WELL OR 150 TO 200 FEET FROM H PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL MINIMUM DISTHNCE FROM 8 PRlVHTE WELL TO H PRIVHTE SENER LINE IS 25 FEET HND TO HCOMMUNITYR�SEWERELINEDISU75 FEET|TURNED TO THE DEpHRTMENT WITHIN ]0 DHYS WELL LOGS M�� �UIx u OF THE HELL COMPLETION OTHER REQUIREMENTS MAY HPPLY. SPECIFICHTIONS HND CONSTPUCTION DIHGRHMS HRE HVHILHBLE TO INSURE PROPER INSTAt- LHTION- W K IT: 1-1 X - V FEE Fo, Y 0, �E�E �'-1 F..", LH.. E.-,3 AL I CERTIFY THAT 1� I HM FHMILIHR WITH THE REQUIREMENTS FOR Or-4--S-IFF:SEWERS HND WELLS HS SET FORTH BY THE MUNICIPHLITY OF HNCHORHGE 2 I WILL INSTALL THE SYSTEM IN HCCORDHNCE WITH THE CODES. ]` I UNDERSTHND THRT THE ON�SITE SE�ER SYSTE� MHY REQUIRE ENLHRGEMENT IF THE R SIDENCE IS REMODELED TO INCLUDE MORE THAN 4 BEDROOMS HPPLICHNT JHMES HITCHCOCK / DHTE ISSUED BY�L������������ 6 4 ---v, -1 PAI y 3.���r- --�f.iu'}�{�� f`�yi t{��ii'..+✓--�'. `} �� fi� �` � .�e.t �t=�. i � � }`1s�t,t�# f t=1 l � �• I iii ';' It�1,�ij�" i.°s� i 's t._.� .- - f-�ly`tl t.,9��{�l IS. yl'� t -` s a= t t7J(.€•3 } t� €4., RA Ii i so RAY 3 }�.."' :'<,i s€.� �7T! �° '-:a � -r e.^•' 3` 1� i }-'S�"�' � � t�r� J'£°�.'i+�Y.�'� �°7r _ t t_• r dl i ri � #'!;5 tas.Fi'31:i t`N f c7y=� i"3 o �'r OR ti;ili lr I iy . �i}tv}# 1t I'f i rte: Ut' 3i iI'13:€3 �}3 'e,Jf s���& s;t rJ1Jr} F I'dIg € OfrM l3i- f `_'s:. `ta'ITI;' C iPd I - i'�. C3�€ V5 NO 11IG i" FOP Ti0JK,} �`- _,. <, e t t . [7 4I} P 6th' iIitf� id �. — I}'9 Y_, ? } .I��t�?AII. t _ _t{ j---_ f� - i��t� � _ 8TION mi ` '6i [ !" ;=f= `, t_ T � :i ?i3 f dire ` 3 F ° •r'13�'d'� I! i €'r' Ps1 0 -I} -ORM rH I b:K':F'i �? i i'# b i' [3tJ9 tPfs 3'rst° IP ;I'rx._t ATION Ig IlW tt r-§I'Y y`Yt�..l r;�,J�t ��l; ro MI'S rY HPIO 1} !i ME- 9 t� r. '::gxy.t�_{.r I'rs�i #}�. i'#�_t. Lari-§- >�tSYf__ �Y xx _ . ,� yq is s L ' g -�• -. y � ,� :�' �� �.'... �"; �-;•.» 1 - a 5. $ � �' �.�. �' ,. r� THOU S•"` 4q•,�, t } (y j �.• p -y yi i_ /� S_ (�+ y-� ��I 1H U7 FIt �i� 5/!,'i `�f_�I IfJIE !'���S.i !�'i fSd-�'rt(Y:e To NIHIPP.tii C d ('tt�'3 erl3- EN A kI£1Lt IFINCI ;qr-"t' i`jg 1t1 .:t314v PE e `ter s �sJi� t� r�'t_is�It� 1���L�i_ C3+.i•t€�I?''F�..- Mi Alaska ' cl-As la PI ( ) 7U 1551 �f '' loot 907 2 (7eietopiee 907)2/1-5742 4040 "B' Street Anchorage, Alaska 99503 October 21 , 1980 W. O. #A19551 or PNC HORPIGE Grid: 3439 ti;UrnIrPury Co ENJ1kGNN�Er;1,-:, Mr. Dar] Rogers J' 6 i) SRA Box Anchorage, Anchorage,A AK 99507 8 Subject: percolation Tests Mountainside Village Gentlemen: Lot 3 We have completed percolation tests on Block oLot 51 Mountainside Block 2, Lots 1, 2, 3, 4; and Block 3, Village Subdivision. 'Pest holes were drilled by Denali Drilling, :Enc. using a continuous flight auger mounted on a Nodwell carrier. r1YTest hole logging and percolation tests were performed by Latch and Mr. T. Barber, Alaska Testlab geologists, and Mr. M-3. Holum, DOWL engineer. After the hole wase drilled, a 3/4" slotted PVC pipe was in- serted in the hole to maintain an open hole. The hole was fi:l.l.ed with waterheand holeeft wasoreiill}ed w�th�l water`. The water following day, level was recorded at 10 ritiin1te evelsA were' betweenn3 andt7 feet. During the tests, the water below ground surface. The minimum percolation rates were observed during the last 10 minute interval.. We suggest that on-site waste disposal systems be designed as follows: Percolation Recommended Rate Absorption Area (rni.nutes/inch) Per. Bedroom (sf) 8.0 150 Block 1 a Lot. 3 2.86 100 Block 2 LO 120.0 225 j.,ot 2 20.0 225 Lot 3 2 86 100 Lo t 4 125 131oCk 3 - 1,0t 5 5.0 9 Page Absorption trenches are suitable for all tested lots. The recommended absorption rate per bedroom is based on criteria in the "Manual of Septic Tank Practice", U.S. Department of Health, Education, and Welfare. A well in the Keno Hills Subdivision is located 104 feet from the test hole at Block 1, Lot 3. The drainage system should not be placed within 100 feet of -this well. The water table was observed at 14 feet below ground surface at Block 2, Lot 2. Drainage trenches should remain six feet above this :Level. We recommend the absorption trenches be inspected prior to installing the system since the tests are based on a 6 inch diameter test hole. Trench conditions will provide a more extensive picture of subsurface conditions. If trench conditions differ significantly from"the test hole condi- tions, the trench length may be changed to improve system performance. The following items are attached: Test Hole Logs Figures 1-6 Test Hole Locations Figure 7 Standard Explanatory Information Sheets 1-3 We trust this report meets your present needs. If we can be of further service, please feel free to contact us. MJH:rb Enclosures APPROVED W? ,, . 0 ac Lam' Melvin R. Nichols, P.E. Laboratory Manager Very truly yours, ALASKA TESTLAB Mark J. Holum OF A44t tp pJ::' •, O'.•' Awlem •�`. Y �o� 17.7 ...r »..t.. &,Joe .............. ••i Melvin R. Nichols 4W 46., No. 4113•E ,•' AW (t� reg'•••.....• 1n dV.4f'Ow"1.°4 �� t3 t. o 1< 2 .- r,c t Mouritain3ide VI -LI -age DeL)th in Feet Front To 0.0` 1.0' 1.0' - 2.0' 2A' _. 1 6- 0' Date: 10/16/80 i.ogged By: O.M. Hatch W.O. 4A19551 Soil Descri ti On [frown Peat (Pt), moist, soft. Brown Sandy Silt (ML), moist, stiff, NP. Brown Silty Sandy Cravel (GM) with occasional cobbles anal boulders, moist=, medium dense, subrounded particles to 29"+. Bottom of Test ifole: 16.0' 1!"rost. Tine: None Observed Free Ywater None Observed L,cvel Type Of Unified Soil Depth Sample Classification ----_ ---- Saw,pI e — --- Grab GM 2 10. U' Grab GM GM 3 15.0' Grab to Sheets 1-3 for unified Soil. -i-cation Classif Rem,rk, Refer I explanation. A `CALASKA MUUMUU COnTROL SMIUS, InC. 5 Cngmeerinq & Cnuironmenlal $ludies P. 0. Box 240668 Anchorage, AK 99524-0668 (907) 279-5553 FAX (907) 276-8706 June 19, 1990 Department of Health & Human Services MUNICIPALITY OF ANCHORAGE Municipality of Anchorage DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION 825 I, Street, Fifth Floor Anchorage, Al( 99,301 , ATTN: John Smith `tl��3 RECEIVED PPI: Lot 3, Block 2, Mountainside Village PID# 020-172--11 Dear Mr. Smith: On September 11, 1989, 1 performed an adequacy gest on the septic system for this house. For 3 hours water was introduced into the system at 3.7 gpm. Except for an initial rise of 0.71 feet for the first 100 gallons, there was no further rise. Upon stopping flow, the system level dropped rapidly. The system was adequate for at least a 4 bedroom house. When the system home. However, existing owner existing system LCR/sr was built, i.t was the house was only were to enlarge the would be adequate. built for a 4 bedroom a 3 bedroom. If the house to 4 bedrooms, the Sincerely yours, Leroy P.eid, Jr PhD, PE, DEE 41cIa%�e' M&86 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel 1. D. 020-172-11-000 Expiration Date: Legal description MOUNTAINSIDE VILLAGE BLK 2 LT 3 Site address 17800 STEAMBOAT DR Anchorage AK 99516 12/14/2023 Current property owner(s) TURNER MICHELLE T &JOHNSON CARL H X The On-site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: Original Certificate Date: 9/14/2023 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval_June 2022 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 020-1 Complete legal description MOUNTAINSIDE VILLAGE BLOCK 2 LOT 3 Location (site address). 17800 STEAMBOAT_ DRIVE ANCHORAGE, AK 99516 Current property owner(s) DAVID & LADONNA MAPSTON LIVING TRUST Day phone 2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: ® Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel ® Plastic ❑ Concrete ❑ Fiberglass Age NEW - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ® Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to. inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ S 5 3U Waiver Fee $ Date of Payment13�z3 Date of Payment COSA # 0 S C Waiver # COSA Application 2022.doc COSA Checklist copy.docx COSA Checklist Legal Description: MOUNTAINSIDE VILLAGE BLOCK 2 LOT 3 Parcel ID: 020-172-11 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled *Unknown Total depth **85 ft Cased to **26 ft *Bedrock at 18’ Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) 24 in. Date of flow test for COSA 7/5/23 Static water level at beginning of test 24 ft. Well production at time of test 6+ gpm Water storage tank volume NA gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate 3.73 mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date 7/27/2023 Comments MO FILE: *Per Dotten Drilling docs dated 3/29/1982. **Per AWPS invoice notes. B. TANK DATA Measured operating fluid level in septic tank NA Date of pumping NEW TANK Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 8/26/81 ALL standpipes present per record drawing Total measured depth from grade 10.1 ft (max) Measured depth to pipe invert from grade 3.8 ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes (MT) go to bottom of effective. (ED) If not, state depth into effective 6.3 ft Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) N If yes, enter date Adequacy test date 7/5/23 Results Pass Fluid depth prior to test 3 in Water added 600 gal New fluid depth 11 in Elapsed time 300 min Final fluid depth 0 in Absorption rate 600 gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) 96 in (MOA 8’ ED) Effective depth used 20 in (Missing ED + Final Fluid Depth) Effective depth (ED) remaining 76 in Comments/Deficiencies: Approximate total measured depths from existing grade. ED per elevation measured shots & appears approximately 1.7’ ED is missing. COSA Checklist copy.docx E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Engineer’s Printed Name CURTIS HUFFMAN, PE Date 9/5/23 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & 9/5/23 Municipality of Anchorage °F - On -Site Water & Wastewater Program (907) 343-7904 ISS�Unc-e— CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 020-172-11 Expiration Date: 7- _a — ( 3 1. GENERAL INFORMATION Complete legal description MOUNTAINSIDE VILLAGE S/D; BLOCK 2 LOT 3 Location (site address) 17800 STEAMBOAT DRIVE *ANCHORAGE, AK 99516 Current Property owner(s) KEVIN & CATHERINE STANGE Day phone 230-4069 Mailing address 17800 STEAMBOAT DRIVE *ANCHORAGE. AK 99516 Real Estate Agent RICK JARVIS W/ REMAX Day phone 276-2761 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System 4 Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $_ _ _ __ _ Waiver Fee $ Date of Payment Receipt Number COSA# Sro I a / 2 -7� Date of Payment Receipt Number Waiver # TYPE OF WASTEWATER DISPOSAL: Individual On-site ❑ Individual Holding tank ❑ ❑ Community On-site ❑ ❑ Public Sewer ❑ Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $_ _ _ __ _ Waiver Fee $ Date of Payment Receipt Number COSA# Sro I a / 2 -7� Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, t verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineers Comments: In conducting this evaluation, GEG, LtD_ attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE System #1 Approved for 4 bedrooms. System #2 Approved for Disapproved. Conditional approval for bedrooms. Phone 337-6179 Date 12 2B 11z bedrooms, with the following stipulations: ON-SITE WATER AND WASTEWATER PROGRAM The Municipality or Anchorage Develop, emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist Septic System Advisory y Nitrate Advisory Arsenic Advisory Well Flow Advisory Other By: c (Rev. Original Certificate Date: 1- 2-___ _L 3_ If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: MOUNTAINSIDE VILLAGE S/D; BLOCK 2, LOT 3 Parcel ID: 020-172-11 A. WELL DATA *PER DOTTEN DRILLING LETTER DATED 3/29/82. **BEDROCK Well type PRIVATE If A, B, or C provide PWSID# N A Well Log (Y/N) YES Date completed 3/29/82 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth *45+ ft. Cased to ** ft. FROM WELL LOG Date of test *3/29/82 Static water level *20 ft. Casing height (above ground) 12+ in. AT INSPECTION 4/26/12 10 ft. Well production *10 g.p.m. 5.4+ g.p.m. WATER SAMPLE RESULTS: Coliform QD colonies/100 ml. Nitrate 3 dmg./L. Collected by: GFG. Ltd. Arsenic: NO ug./L. Dateofsample: 12/10/12 B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 8/26/81 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (YIN) YES Depression over tank (YIN) NO High water alarm (YIN) N/A Date of pumping 4/26/12 Pumper ONE STOP SERVICES C. ABSORPTION FIELD DATA *BELOW EXISTING GRAnE Date installed 8/26/81 Soil rating (g.p.d./Wor /bdrm 225 System type TRENCH Length 58 ft. Width UNSPECIFIED ft. Gravel below pipe 8 ft. Total depth *1 1.8 ft. Eff. absorption area 928 ft2 Monitoring tube **YES Depression over field NO Date of adequacy test ***4/27/12 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 42 in. Water added 755 gal. New depth 54 in. Elapsed Time: 120 min. Final fluid depth 47 in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE If yes, give date — **SUMP ONLY EXTENDS 6.25' BELOW INVERT OF DRAINPIPE. TOTAL DEPTH AND LIQUID LEVELS CALCULATED. ***HOUSE WAS VACANT AT TIME OF TEST. DRAINFIELD PRE—SOAKED ON 4/26/12 WITH 2000 GALLONS. D. LIFT STATION Date installed Size in gallons Manhole/Access(YIN) "Pump on" level at in. "Pump offlevel High water alarm level at in. Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot *95,+ On adjacent lots 100'+ Absorption field on lot 100 + On adjacent lots Public sewer main N/A Sewer /septic service line 25'+ Animal containment areas 50'+ Public sewer manhole/cleanout Holding tank N/A Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field **5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS 1. **PER 1981 INSPECTION REPORT, G. ENGINEER'S CERTIFICATION i certrfy that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date It2/2,11 /12 (Rev. 11105) Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 x(907) 343-79k.us 04 N" CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 020-172-11 COSA# 1. GENERAL INFORMATION Expiration Date: /0 -2 L5) ` /, Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address MOUNTAINSIDE VILLAGE S/D; BLOCK 2, LOT 3 17800 STEAMBOAT DRIVE * ANCHORAGE, AK * 99516 KEVIN & CATHERINE STANGE Day phone 907-230-4069 17800 STEAMBOAT DRIVE * ANCHORAGE, AK * 99516 Day phone Real Estate Agent RICK JARVIS W/ REMAX Day phone 276-2761 Mailing address 110 W. 38TH AVENUE, #100 * ANCHORAGE, AK * 99503 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water. System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, t verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNERS, P.E. Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. the operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will It confer any legal right whatsoever. 5. DSD SIGNATURE _1Z Approved for _A__ bedrooms. Disapproved. Conditional approval for bedrooms, with the following Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory Phone 337-6179 Date O z y AGarness: PCE-793 �o OpfP a Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other ON-SITE WATER AND WASTEWATER PROGRAM By: o ! – Original Certificate Date:/— (Rev. it/0 ) Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: MOUNTAINSIDE VILLAGE S/D; BLOCK 2, LOT 3 Parcel ID: 020-172-11 A. WELL DATA *PER DOT -FEN DRILLING LETTER DATED 3/29/82 Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) YES Date completed 3/29/1982 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth *45'+ ft. Cased to **BEDROCK Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test *3/29/1982 4/26/2012 Static water level *20 ft. 10 g. Well production *10 g.p.m. 5.4+ g.p.m. WATER SAMPLE RESULTS: Coliform n colonies/100 ml. Nitrates' _q1 mg./L. Collected by: GEG, Ltd. Arsenic: k O ug./L. Date of sample: 4/27/2012 B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Tank size 1250 gal. Number of Compartments 2 Date installed 8/26/1981 Cleanouts (YIN) HOW Foundation cleanout (Y/N) YES Depression over tank (YIN)NE High water alarm (YIN) N/A Date of pumping 4/26/2012 Pumper ONE STOP SERVICES C. ABSORPTION FIELD DATA Date installed 8/26/1981 Soil rating (g.p.d./ft2or /bdrm 225 System type TRENCH Length 58 ft. Width UNSPECIFIED ft. Gravel below pipe 8 ft. Total depth *11.8 ft. Eff. absorption area 928 ft2 Monitoring tube YES Depression over field NO Date of adequacy test **4/27/2012 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 42 in. Water added 755 gal. New depth 54 in. Elapsed Time: 1 EO min. Final fluid depth 47 in. Absorption rate >= 600+ g,p,d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date — *SUMP ONLY EXTENDS 6.25' BELOW INVERT OF DRAINPIPE. TOTAL DEPTH AND LIQUID LEVELS CALCULATED. **HOUSE WAS VACANT AT TIME OF TEST. DRAINFIELD PRE—SOAKED ON 4/26/2012 WITH 2000 GALLONS. D. LIFT STATION Date installed Size in gallons Manhole/Access(YM) "Pump on" level at in. "Pump ofr level High water alarm level at in. Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot *95'+ On adjacent lots 100'+ Absorption field on lot 100'+ Public sewer main N/A Sewer /septic service line 25'+ On adjacent lots Public sewer manhole/cleanout N/A Holding tank Animal containment areas 50'+ Manuretanimal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field **5' Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/v chicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots -2 —()V+ F. COMMENTS 1. **PER 1981 G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and p 4 .•�,r review of Municipal records that the above systems are in conformance with MOA COSH guidelines in effect on this date. a.... .f. ...Go ness;' Engineer's Printed Name JEFFREY A. GARNESS �� ,j CE— m� Date U- 30 Ila d�n'zaP l- COSA Fee $ '-f'Zo Date of Payment/ Receipt Number (Rev. 71105) Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage arvE Community Development Department Development Services Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Nitrate Advisory Certificate of On -Site Systems Approval # 121272 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block 2, Lot 3 of Mountainside Village subdivision. This inspection revealed a nitrate concentration of 5.41 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. FROM :Alpine Drilling FAX NO. :907 345 0202 May.22 2012 12:02PM P3 AAROW PUMP & WEU SERVICE, LLC p�]dQo plc'[ P.O. Box 110496 i Anchorage, AK 99511 No. 9372 Office: (907) 346 9355 •Fax (907) 333-8976 / _fnL et� Eagle River: (907) 622-9335 (� CUSTOMER -ZZI AEO S''u �Qv� L �Po.;'- X30 - x'06 J L JOB SITE rz Oil je J INVOiICE DATE/ WELL DEPTH/ SWL / CHLORINATED PUMP DEPTH / SAL PERSON W,...:: .....' ..,.>, .. '..:.„#.a^...,..':. ..: ...DEBORIPTION ..: •. 1. '70, LABOR HOURS RATE AMOUNT TOTAL MATERIAL avow/ iI' �S �. Q TOTAL LABOR WORK ORDERED BY DATE COMP. TOTAL LABOR PAY THIS AMOUNT 3311 "ThankYou SIGNATURE (I Hereby Acknowledge the Satisfactory Completion of the Above Described Work and agree that if above work is not paid for in 90 days I agree to allow Aarow "Pump & Well Service, L.L.C. me right to remove unpaid for equipment and charge for labor already performed & labor to remove unpaid for equipment). TERMS: ACCOUNTS PAYABLE AT 10TH OF MONTH FOLLOWING PURCHASE. S. SERVICE CHARGE AT RATE OF 15% PER MONTH WILL BE CHARGED ON OVERDUE ACCOUNTS, I ASBUILT SEIJA:cD IF. AEP.EBY CERTIFY THAT 1 HAVE SURVEYED THE SCALE. FO -LOWING DESCRIBED PROPERTY- _ rwrvif�rii✓� �itr sva «'� fir: z DATE. AND THAT NO ENCROA:HMENTS EXIST 6XEEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE DOSTENCE OF ANY GRID, EASEMENTS, COVENANTS, OR RESTRICTIONS 3t39 WHICH DO NOT APPEAR ON THE RECORDED SUBDI- VISION PLA?. UNDER NO CIRCUMSTANCES SHOE➢ R F8: ANY DATA HEREON BE USED FOR CONSrRUCTIDN OF FENCE �.lNES, OR FOR ESTABLISHING BOUND- ARY LINES. �f L,^.NII Y 0 _nM I, P.1 U MUNICIPALITY OF ANCHORAGE • DEPARTMENT OF HEALTH & HUMAN SERVICESD Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel 1. D. # a _.d— I"T 2 - I I \r HAA #� .2 L��21 I- 1. GENERAL INFORMATION Complete legal description I -o i✓ 3 P,K Location (site address or directions) )78D D Ste,„ '�ag� -D-rt yQ_ k`ciuL,'\ o2ZR (o(o!� Property owner S74 — Day phone ( Mailing address — 1786 g9yt& 3y S- 3!740 Lending agency .1 )e � ��+� Day phone Mailing address Agent Address Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: V 3. TYPE OF WATER SUPPLY: Individual well Community well Public water Day phone NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. h. TYPE OF WASTEWATER DISPOSAL: / Individual on-site ✓ Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA a21 �. 11 1 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I furtherverify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm l D 6/0e y av r kZak df �E Phone !V q- 311 b Address c�d 3 ie f >� �*,;Za 6 Engineer's signature V — 6. DHHS SIGNATURE Approved fore=�' bedrooms. Disapproved. Conditional approval for Additional Comments Date It J23 IQ 7- bedrooms, with the following stipulations: By. L1 , ,, (J=� -C Date�— IIITIr The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev, 1/91) Back MOA 421 Municipality of Anchorage Department of Health & Human Services HEALTH AUTHORITY APPROVAL CHECKLIST 19 L3 Legal Description: _/8K,2 r��7ilw�aivt�iCL� V+ U Parcel I.D. A. WELL DATA Well type If A, B, or C, attach ADEC letter. ADEC water system number r)/A' /.29/6 Driller_ D64eti Log present (Y/N) _L Date completed — it Total depth _ _�� Cased to _�'a�� Casing height— � Sanitary seal (Y/N) �� Wires properly protected (Y/N) — FROM WELL LOG AT INSPECTION Date of test M Static water level 1 D Well flow g.p.m. ate—_ g.p.m. f�n ° �'"� 0 Pump level _ — --� — C) rva "- co O SEPARATION DISTANCES FROM WELL TO: Iiv ucw '`eelg9 n adjacent lots } z � 9�°w � ®O2 Septic/holding tank on lot ,� Absorption field on lot — ' /00 ; On adjacent lots I Z� N () �'� Nlld\ Public sewer main Public sewer manhole/cleanout Sewer service line moi- _Petroleum tank P,__ WATER SAMPLE RESULTS: Of Coliform Nitrate —� Other bacteria i i � _,;� 4�e t4� Date of sample: _ 0F Collected by: — B. SEPTIC/HOLDING; TANK DATA Date installed 7'i��J Tank size 1,9 ,5 L) Compartments S � Z' Cleanouts (Y/N) Foundation cleanout (Y/N) Depression (Y/N) N High water alarm (Y/N) r� Alarm tested (Y/N) N�A / I Date of pumping Pumper SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Wells) on lot IF On adjacent lots i 12 U Foundation /b To property line ,>' 6V Absorption field Water main/service line i J O Surface water/drainage — N� ! C 72-026 (Rev. 7/91) Front CONTINUED ON BACK PAGE C. LIFT STATION 1 ll� Date installed Size in gallons Vent (Y/N) High water alarm level "Pump on" level at Meets MOA electrical codes (Y/N) Manufacturer Manhole/Access (Y/N) SEPARATION DISTANCE FROM LIFT STATION TO: Well on lot D. ABSORPTION FIELD DATA On adjacent lots "Pump off" level at Cycles tested Surface water _ Date installed Soil rating System type I Ae4,t e�li Length Width. Gravel thickness 16 Total depth 1 i Total absorption area 9z g Cleanouts present (Y/N) 1� Depression over field (Y/N) Date of adequacy testi f t -2,0 1 Z_ Results (pass/fail) for / bedrooms Peroxide treatment (past 12 months) (Y/N) >' 7 If yes, give date SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot % 10-0 On adjacent lots �� / Z 0 Property line 1 2� To building foundation o ± To existing or abandoned system on lot r�/A On adjacent lots > !! 2-v Cutbank N-0 41 e_ Water main/service line ,'Z_ � Surface water �P-11Drivewayarkin /vehI t ''Z Curtain drain �6 o E. ENGINEER'S CERTIFICATION i , p g s e s orage area I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signature v! p 1 /� Engineer's Name i �� Qy J Dv Y- t� its Date It "�-3� aZ HAA Fee $ Z 20 Waiver Fe � $ Date of Payment 2- _� �� Receipt Number 2 z 72-026 (Rev. 3/91) Back MOA 21 e. Date of Payment Receipt Number MUNICIPALITY OF ANCHORAGE • T Department of Health & Human Services 14}1 DIVISION OF ENVIRONMENTAL SERVICES —� 343-4744 CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING Parcel I.D.#—LS — 1~ 1 1 \ HAAff i=`t���? -- 1. GENERAL INFORMATION (Must be completed prior to submittal) (a) Legal Description (include lot, block, subdivision, section, township, range) —! -3 45'�9oc ,k�.a� lc� 5� %_34J S// Location (addre'ss or diredtions) r (b) Property'oWnbr &V T1 `"�'��� Telephone: (home) Business Mailing'Ad'dress r (c) Lending Institution ` Telephone — Mailing Address (d) Real Estate Company and Agent Address Telephone (e) Mail the HAA to the following address: (or check here/K if hold for pick up.) List contact person and day phone number below: C £-S G„ , / / ,E 2. TYPE OF RESIDENCE: Single-FamilyX Number of bedrooms -3 3. WATER SUPPLY Individual Well X Community ❑ Public ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to th legality and status. 4. SEWAGE DISPOSAL On-site P Public ❑ Community ❑ Holding Tank ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legailty and status. 72-025 (Rev. 7/88) Page 1 of 2 Z to Z abed 8Oe6 (9912 ADU) 9ZO-U �aom s,jaauibue leuolssaload ay} ui suolsslwo jo saoaaa aol alglsuodsaa lou si abeaoyouy to 4l!led pun" ayl -panssi si aleollpeo e aaolaq elep az (leue io suoiloadsui Ion puoo lou op SHHO to saaAoldwd -sluawailnbei alels pue leaapal uieliao /lsiles oliepio ui suoilnlllsui bulpual ilayl pue sawoq to saasegoind of /selinoo e se slyl scop SHHO ayl 'e�seIy to alelS ayl ul paaalsl60a jeauibua Ieuolssaloid Iuapuadapui ue Aq anoge 9 ydwBeied U uaAIb suoileluesaidai ayl uodn Aluo paseq paleoilpao lenoaddy Al!joglny ylleaH sanssi (SHHO) saolAaaS uewnH pue ylleaH;o luawlieda0 a6eaoyouy to Al!ledlolunA ayl MOUL NdO lenoaddy euoll!puoO to swaal leuoll!puoO panoiddesi0 % panoaddy ale Aq swooapaq - aol panoaddy TdAOadd`d SHHO •9 rQP 0 to 1' • •i 1. • '� 'Omli . ... rrr►rr• •rrrrr• •j At _I� i� oleo 990 — z )'— -,5 -7 0), r ov ssaippy SSS 5-/oGZ� auoydalal �2 577 Wald loaWeN -uolloadsul slgl to alep ayl uo loa;la ui suolleln5ei pue 'seoueulpio 'sepoo alelS pue ledlolunW !le yl!m eouelldwoo ui sl walsls lesodslp aaleMalsum ao/pue Alddns aalenn alls-uo ayl 'uolloadsul pue uolle61ls9nu1 AW wool pue sal!} abeaoyouy to Al!ledlolunW ayl wool paulelgo uollewaolul ayl uo paseq legl AJ!JGA Jaylin; I -ulaaay poleolpul ainlonals to ad j pue swooapaq;o aagwnu ayl aol alenbape pue leuollounl 'ejes sl walsAs lesodslp aalumalsem ao/pue llddns aalem al!s-uo ayl leyl smogs lenoiddy Al!aoylny ylleaH dill to u01le61lsanu1 AW leyl /+l!JaA I 'molaq uMoys alep uollep!!eA ayl to se pue olaaay pail;le leas (w !q pal;paao sy NO11` YYHOdNl aNd ViVG `HOdd3S 3l1d `S1S3J. `SNO1103dSN1 JNId1AOHd Wdld JNIa33NION3 '9 MUNICIPALITY OF ANCHORAGE (MOA) WT..thority Approval (HAA) LITY OlF At I�IfD��IST - FEBRUARY 1984 OF HEALTkI. & 343-4744 ENVIRONMENTAL PROTtCTION Legal Description: A. WELL DATA RE "'' E `V E D Well Classification s -v If A, B, C, D.E.C. Approved (Y/N) Well Log Present6A Date Completed YAC 2 Yield Total Depth 0 Cased to Depth of Grouting 0At1 Jua"Ji GL J e Fr r_G4a Static Water Level Pump Set At Casing Height Above Ground —_ Electrical Wiring in Conduit&) SEPARATION DISTANCES FROM WELL: To Septic/Holding Tank on Lot To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line —/" To Nearest Sewer Service Line on Lot Water Sample Collected by Sanitary Seal on Casinq#)N) Depression Around Wellhead (Y11P ` 5- ; On Adjoining Lots /to / ; On Adjoining Lots i /00� To Nearest Public Sewer Cleanout/Manhole Date �`/� !7 Water Sample Test Results At Al Comments /1%a/v� a /r «+• a/I�a��c;/ B. SEPTIC/HOLDING TANK DATA Date Installed V__ z__Size _ e No. of Compartments Standpipes 6,)N) Air -tight Caps 6yN) Foundation Cleanout &N) Depression over Tank (Yf)) Date Last Pumped Purnping/Maintenance Contact on File (Y/N) A)A ; for Holding Tank High -Water Alarm (Y/N) � Temporary Holding Tank Permit (Y/N)/fl SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK: To Water Supply Well__ To Building Foundation To Property Laine i To Water Main/Service Line To Stream, Pond;' Lake or Major Drainage Course Comments L, To Disposal Field 72-026 (Rev.,7/88) From Page 1 of 2 7 L� 15'� /S/ C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata/ S �Z Type of System Design �� 5 Date Installed _� (` Length of Field 51;? / Width of Field &0 _ N Depth of Field Gravel Bed Thickness Square Feet of Absortion Area Depression over Field (Y�9 Results of Last Adequacy Test k SEPARATION DISTANCE FROM ABSORPTION FIELD: To Water -Supply Well / E q To Building Foundation Statndpipes Present K -?N) Date of Last Adequacy Test FA To Property Line To Existing or Abandoned System on Lot On Adjoining Lots '21 To Water Main/Service Line To Cutback (if present) To Stream, Pond, Lake, or Major Drainage Course /E>n To Driveway, Parking Area, or Vehicle Storage Area /0-/ Comments D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level. at Tested for Meets MOA Electrical Cod /N) Comments Dimensions Manhole�ess (Y/N) '*Check Permitted Bedroom Rating Against HAA Request" I certify that I have checke inspection. Signed Company Date ;L MOA No. Pump Off' Level at Vent (Y/N) A.) Pumping Cycles during Adequacy Test. or c(/l/o/�nformed to all MOA and HAA guidelinesJin e O�•b1p`Qd�a�te of this 0. 1_/Y/1 ° HH •• GaY ��A%4 9T �••• •••••°• M 61'% Seal s° °° . • °° •e.•. Receipt No. u L /—� Date of Payment Amount: $ Receipt No. _ Waiver Fee: $ Date of Payment 72-026 (Rev. 7/88) Back Page 2 of 2 ROY C. RFID. • E •. CE -2251 ° `' • �P nf. e E `tE ..M.Y .. 'sly wµ ■ � lM{ (( OF y L DEI®F NIRTM:EN f HEnTH & EUdW RONIANTAL /A81 EC�10M l,: t ENWROOK TAL ENOINEERINO DIVIiION Attel�l'1tsM. MUM iii g Tddokw 7iii71r x M L . ,.,. WELL INSPECTION REPOIRP ON•�7'E SEWAGE DI$POI;AI.31fS'VE ANDS ;,� ,�, .�..+.�a . L• Y itl l WIN '+S�'• � Y � YI���� � A ii Ah r 'r fl� li<<r -+i'Y"� a��;��C1j,�L �•, ��L�S�►��N„ ���� •��AAd, 010. OF BEDROOMS 1} rcfl L' C4 r' tirvl SIC1'its �`;w P&L .a com"rt,mm" Inid�knyth.. Vwdth L.i4wA/�MI, 5 IF HDYEIIMDE. �•IR W TO.. 11iy „l i d 11� lsaA gyp PERMIT -000 ,�r�®res � � � y'.tl. •d`' � Y FoundVm ... - �O pyya�/ye Y,A• fit: bt3TA1�'1� N M0. M MwM ��- IMa Toolwoe oA lino T Wr Oiw��w tM@tt�en Illw 1 r+,yu ; _- e. '' Ow Te►"a P" INT rim `• ) M is'ir t? ,iv.• ti�PIM1M - M,V GV, V,/K'iIW am r r,(„- fdNwMNon >Otli►r " Dryer Diela�ro� w lot Iino T M0. .: r,,•:,.,,+. ;. & _ f. �'� � x •+�0 tatrlduNcs Earwr itti soptk tOrNc f S�Is tltlM rrMW �:;(� L t �y)s . ., ANC11'�" r {{�� k'rrti�:Ygq\uyYm�tc� it L W ,'K f� K ,+r�k , YY rYSdi l��!AJ�)�h ifs. Wi I. f16- �.. ray s $ lit1 ' r• DATE t.EGl1l. i •r„ r";1 tt �,t�� hti�f aYll�wry� Municipality ®f Anchorage Department of Health and Human Services dhh5 825 "L" Street Tom Fink, Mayor P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 September 26, 1989 Lee Reid, P.E. Alaska Environmental Control Services, Inc. PO Box 240668 Anchorage, Alaska 99524-0668 Subject: Waiver Request for Lot 3 Block 2 Mountainside Village Waiver Request #WR890051, PID #020-172-11, HA890368 Dear Mr. Reid: Your request for waiver of the required 100 foot separation of a septic system to a private well has been approved. The approved separation distance is 95 feet. This waiver approval applies to the existing septic system to well separation only. Any future upgrade to either will require all separation distances be met or another approval from this department. Sincerely, - Daniel J. Roth Civil Engineer On-site Services DJR/ljw#6 ALASKA RuinoWnTAL COMROL SMUS, MC. engineerinq & Enuironmentol Studies L -L 2 �'l L)C-)5(q P. 0. Box 240668 Anchorage, AK 99524-0668 (907) 279-5553 September 13, :1989 Municipality of Anchorage Department of Health & Human Services 825 L Street, 5th Floor Anchorage, AK 99501 3 RG: Block 'e, Lot -2-, Mountainside Village On September 11, 1989, while I was performing art adequacy test on the subject house, I noted that the well that had been installed after the sewer system had been built, was not 100 feet from the septic tank, but only a distance of 95 feet. It is over 100 feet from the on-site system, and there are no other systems around upon which it would infringe. The septic tank was installed in 1981, so it should be in good condition. Although the septic tank is at a higher elevation than the well, the drainage from the septic tank would probably he to the west instead of to the east toward the well. The house and well are on a ridge that runs roughly northeast --southwest. There is no really good well log on the files. It was drilled by Dotten Drilling, and shows rock at 18 feet, static water level at the time of drilling was 20, but on the day of testing the static water level was 13 feet below ground, and the drawdown stopped at 28 feet. Since this is ,4 „1 /rerj w?) av F ii ir-* anrh S®�om� n�n_t cg a relatively high area that is well drained, there does not appear to be a problem with the water table. The bacteriological counts for the well were zero, and the nitrates were 1.8 mg/1 which is well below 10. The soils in the test are rated at 225 sq ft per bedroom and with a brown silty GM (medium (tense). In my professional opinion, I believe the issuance of a waiver of 5 feet from the 100 required from the well would not create a health hazard. Please issue the waiver to this effect. LCR/sr _ APPLIC NT FILLS OUT UPPER HA[ ONLY Properly Owner - ; .. / ... ( ((-.—-- Phone -- Date Date Date Mailing Address - , �^ Zip Code Inspector Buyer _ - - Address _ Zip Code Lending Institution - -- -. _ _- F- -- Phone r DEPT. OF ENVIRONM NTAL,BROTECTION Address —•=-1 Zip Code ;x,19 f� '� s�-• � Realty Co.& Agent Phone Address Zip Code Legal Description 'CONDITIONS OF APPROVAL ( ) DISAPPROVED Street Location ( OCOTIO NROVAL'DATe� BY:S1! Type of Residence 7C Single Family - - ❑ Multiple Family No. of Bedrooms_ ,` Other — --- --- Water Supply --- -- -- ---— — --- �[7' Individual ^ - , � , - ATTACH WELL LOG. A well to weg is required for all wells drilled since June 1975. ❑ Community -; - For wells drilled prior to that date, give well depth (attach log if available). ❑ Public Utility Sewer Disposal P'Individual Year Individual Installed: Ll Public Utility When Connected to Public Utility: ❑ Holding Tank -- NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 1 Time Time Time - -- Time Date Date Date Date e_� 1� Inspector Inspector Inspector Inspector Field Notes: !�, (y� , pJ.%`� �,� b MUNICIPALITY OP ANCHORAGE HEALTH i r DEPT. OF ENVIRONM NTAL,BROTECTION iU �,�o � , � c^ l� 1 ' � �� - � � ;x,19 f� '� s�-• � RECEIVED ( ) APPROVED BEDROOMS 'CONDITIONS OF APPROVAL ( ) DISAPPROVED ( OCOTIO NROVAL'DATe� BY:S1! Solis Rating Z S_ 1yG�G�c,� Date Sewer Installed Well To Absorption Area ✓B-%'� p Well Log Received G� �! Well to Tank q�eptic Tank Size j�