Loading...
HomeMy WebLinkAboutMOUNTAINSIDE VILLAGE #1 BLK 4 LT 15Rick Mystrom, Mayor Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 cc: Robert C. Cowan, P.E. November 14, 1994 Mr. Duane Stark 4001 Romanzof Circle #A Anchorage, AK 99517 Subject: Lot #15 Block #4 Mountainside Village #1 Permit #SW930275, Parcel ID #020-172-58 Dear Mr. Stark: The subject permit, issued August 10, 1993 by this office for a single family well and/or on-site wastewater system, has exph'ed as of August 10, 1994. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. ff you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If the on~site wastewater system has been completed and a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and clocumentation. All inspection reports must be subrnitted within 30 days of cons~uction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. Sincerely, Jah-nes Cross, P.E. Program Manager On-Site Services JC/kb PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW930275 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:STARK DUANE & TERRIE OWNER ADDRESS:4001 ROMANZOF CIR. #A ANCHORAGE, AK 99517 DATE ISSUED: 8/10/93 EXPIRATION DATE: 8/10/94 PARCEL ID:02017258 LEGAL DESCRIPTION: MOUNTAINSIDE VILLAGE #1 BLK 4 LT 15 ~ LOT SIZE: 71246 (SQ. FT.) NUMBER OF BEDROOMS: 5 THIS PERMIT: 5 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY' CALLING 343-4329 OR 343-4681 AFTER BUSINESS HOURS 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: DATE: DATE: ROBERT SHAFER, P.E. ROGER SHAFER, P.E. July 27, 1993 CIVIL ENGINEERS (907) 694-2979 FAX 694-1211 HEALTH ADTHORITY APPROVAt S SEWER & WATER MAIN EXTENSIONS SEWER & WATER INSPECTION ENGINEERING STUDIES AND REPORTS WFLL INSPECTION & ELOW TEST SI'I'~ PLANS ROAD DESIGN SOIL TEST PERCOLATION TEST S1 RUCTURAL & MECHANICAL INSPECTIONS ON SITE WASTE WATER DISPOSAL SYSTEM DESIGN Municipality of Anchorage DEPAR~%~ENT OF HEALTH AND HUM_AN SERVICES 825 'L' Street P.O. Box 196650 Anchorage, Alaska 99519-6650 REFERENCE: Mountainside Village Subdivision, Block &, Lot 15 Request you issue a permit to drill a well and install a septic system to serve the proposed five bedroom house on the referenced property. Two test holes were excavated and percolation tests performed. The approximate location of the test holes are located on the attached site plan. The monitoring tubes within the test holes have been checked and found to be dry. This property has enough area for a septic upgrade which can be seen on the attached site plan. We do not anticipate any adverse effects on neighboring properties by the installation of the proposed septic system. If you have any questions, or require additional information for your review, please contact us. P.E. 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 / ,Og = ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS REFERENCE: MOUNTAINSIDE VILLAGE SUBDIVISION, BLOCK 4, LOT 15 ~ENERAL: 1. o o The scope of this project includes the installation of a 1500 gallon septic tank and five foot wide drainfields to serve the proposed five bedroom residence for the referenced property. Construction shall be in accordance with the approved site plan and design drawings; Municipal permit with any special provisions or conditions; and all applicable State and Municipal Wastewater Disposal Regulations. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two cleanouts for pumping access. 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 3. Ail standpipes on the septic tank sha].l extend a minimum of 12 inches above final grade. 4. Septic tanks installed with less than 4 ft. of cover shall be insulated. Page Two Mountainside Village Subdivision, Block 4, Lot 15 July 27, 1993 o A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed- up) before gravel (sewer rock) placement. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. o A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter and installed approximately in the locations shown on the design. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. o Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. Page Three Mountainside Village Subdivision, Block 4, Lot 15 July 2?, 1993 MINIMUM F~ATERIAL SPECIFICATIONS: 1. Any septic tank proposed for constructed by a Municipally manufacturer. installation must be approved septic tank 2. The following pipe materials are approved for use in septic system installations in the Municipality of o 0 o 0 Anchorage: _Tvpe. of Pipe Cast Iron ASTM D3034 (PVC) ASTM F810 (HDPE) ASTM D2662 (ABS) Perforated Solid Yes Yes Yes Yes Yes No Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. Ail leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with ].ess than 3% passing the #200 sieve. When sand is being used as a filter material, it's gradation specifications must conform to AMC 15.65.060D. Page Four Mountainside Village Subdivision, Block 4, Lot 15 July 27, 1993 INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 0 The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 0 The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre- construction meeting will take place on-site. Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 'L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST 10 11 12 13 14 15 16 17 18 19 20 DATE Township, Range, Section: SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Depth to Waler After Monitoring? Reading Date :)% Net Time Depth to Water -. · (m~nules/~nch) PERC HOLE DIAMETER I~ ~ ' Net Drop ~HFoRMED BY t ~ ) , ~ oo1~ i~')~ld N~ 9t~,1 ~15~ ~ CERTIFY THAT ACCORDANCE ~]~t~'~IPAL GUIDELINE~/ECT ON THIS DATE. DATE: 72 ~8 (Rev 4/,~) PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LEGAL DE$CRIPTION:,~/"/I~, ,~J~_ ////.~/)(~~' .~/'/.~ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20- Township, Range, Section: SLOPE WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Depth ID Waler Alter ~onilorie~? ~")~-~ Dale:.. SITE PLAN I- N Reading Date Gross Net Depth to Net __.. Time Time Water Drop - PERCOLATION RATE ] ~:)"~' (minutes/tach) PERC HOLE DIAMETER ACCORDANCE ~.t~'~J~C~t~S~/gt'.L~AJ~J~;IPAL GUiDELiNF~.,bi~FF~ ON THIS DATE. DATE: 72-008 (Rev, 4185) ~