HomeMy WebLinkAboutMOUNTAIN VALLEY ESTATES BLK 3 LT 2Onsite File Mountain Valley Estates Block 3 Lot 2 #050-631-02 7` f W_ F4 Municipality of Anchordge AUG2612019MW On -Site Water and Wastewater Section • (907) 343-7904 Page of 2 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181222 PID Number: 050-631-02 Dwelling: ❑® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New Al Upgrade Name ROBERT SUNDBERG ABSORPTION FIELD ❑ Deep Trench W Wide Trench ❑ Bed ❑ Mound Site Address 5050 H I LAN D ROAD __JOther Phone Number of Bedrooms Soil Rating Total depth from original grade 3 4.0 GPD/SF 4.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 3.5 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Mountain Valley. Estates 3 2 Fill added above original grade 0.0 Ft. Gravel length 24.0 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 120 FtZ 1 N/A Ft. Well 75.3' 92.4'(e) TANK 9Septic ElS.T.E.P. [I Holding El Other / Manufacturer ADVANTEX Capacity 15500 Gal. Surface Water 1001+ 100,+ Material Number of compartments Lot Line 5'+ 10'+ NA FIBERGLASS 2 Foundation10'+ 101+ I LIFT STATION Manufacturer Capacity Remarks Gal. Alarm location Electrical installed by Installer PIPE MATERIAL House to tank 3034 drainfield Tank to 3034 Jr's Septic Services Drainfield 3034 CO/MT3034 Inspector Pannone Engineering Services BENCH MARK (Assumed elevation) 1640.5 ft Inspectiones: 151 8/15/18 2�d 9/1/18 Location and description 3`d 9/1/18 411, 7/29/19 BOTTOM PORCH STEP ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date ,�,� OF / _ Septic System Approved X0.2�`'�4��3`'. Z'*. eel Pnnnoiac- ¢ :.. 3' • pr Date �� � a, 11,,•x•: • - ,r�•4: Note: this this approval does not include well permit requirements. �D0�V)00D I O CC) CLI n�bOpcOz�rpi-nOCmzCr�rnx Ab --+ M m M >m-0" r�11 _O > mbb�O0 N O 4 rn r r0-C�OCi p rn > W m Z z z zm��o z � O <� p Z rn m m> > O Nn b b v > r n cm N\ a b FC I IdANHOLE o� x Oo z MANHOLE DOUBLE CLEAN OUT if CLEAN OUT MONITOR TUBE NOTES: T RECORD DRAWING I1 DRAWN I ACP SITE PLAN TUBE CLEAN O CLEAN OUT 8"1 E,(N>Vl M-ovz -u OA -C 10 00 rm>p b�0 ZV/r=. BIZ• .� r >m C7 m min czi�o">-i�N� D Z mmp 50 N A �N.. NOO Nm �p mOp� 0 U! N -+ . m -moi m ri rn�i 0 > u (n F3 z 1100 o Z� z A a O N X m n D O O > ~ S m > >0 � b i - A S NA Ln (Zn. O - z _ _n / Dr Z50G7ulcn m m > z = _ O Z r � > Z 7_ /m - - -i to Cn b - - r - / b>00Ob cnFivp0- _ _ - --- _. - \ gwl'rnnp mogr 0 -a z ? / :'T m > p O O7 11 C,' + ao m m / IO0 -uz -"F"�1 r — --- n -D0 00 / ! / —i O — \ > Z PANNONE ENG SVC, LLCP.O. rn !io 10m �E O . icy,• (MOUNTAIN VALLEY EST B3 L2 ROBERT SUNDBERGte�eH'R.• .... .. SE SND ROAD -Z_ P� r m 1iN� EAGLRIVER 995779e-� n N n N m ? a 41- 41 NOTES: T RECORD DRAWING I1 DRAWN I ACP SITE PLAN TUBE CLEAN O CLEAN OUT 8"1 E,(N>Vl M-ovz -u OA -C 10 00 rm>p b�0 ZV/r=. BIZ• .� r >m C7 m min czi�o">-i�N� D Z mmp 50 N A �N.. NOO Nm �p mOp� 0 U! N -+ . m -moi m ri rn�i 0 > u (n F3 z 1100 o Z� z A a O N X m n D O O > ~ S m > >0 � b i - A S NA Ln (Zn. O - z _ _n / Dr Z50G7ulcn m m > z = _ O Z r � > Z 7_ /m - - -i to Cn b - - r - / b>00Ob cnFivp0- _ _ - --- _. - \ gwl'rnnp mogr 0 -a z ? / :'T m > p O O7 11 C,' + ao m m / IO0 -uz -"F"�1 r — --- n -D0 00 / ! / —i O — \ > Z D r m C A z m zi - k} 0 REVISIONS (DATE 7/30/2019 REV 1: 1/13/2020 SCALE 1" = 60' P.I.D. NO 050-631-02 PERMIT NO. OSP181222 SHEET 2 OF 2 PANNONE ENG SVC, LLCP.O. 17 PHONE 9070X7458200 L FAX 90799645) 745-8201 �E O . icy,• (MOUNTAIN VALLEY EST B3 L2 ROBERT SUNDBERGte�eH'R.• .... .. SE SND ROAD CE EAGLRIVER 995779e-� n D r m C A z m zi - k} 0 REVISIONS (DATE 7/30/2019 REV 1: 1/13/2020 SCALE 1" = 60' P.I.D. NO 050-631-02 PERMIT NO. OSP181222 SHEET 2 OF 2 n N N n N n N N ? a 41- 41 41 N -P' V CD O N U) N 'Cli O D CO u cn N Com+ N N N —• CA UD O 41 W A Cn � co - D r m C A z m zi - k} 0 REVISIONS (DATE 7/30/2019 REV 1: 1/13/2020 SCALE 1" = 60' P.I.D. NO 050-631-02 PERMIT NO. OSP181222 SHEET 2 OF 2 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP181222 Work Type: Septic Upgrade Effective Date Expiration Date: Tax Code Number: 05063102000 Site Legal Address: MOUNTAIN VALLEY ESTATES BLK 3 LT 2 G:0658 Site Mailing Address: 5050 HILAND RD, Eagle River Owner: SUNDBERG ROBERT Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: »1 C11t Departnie11t g/Zralio doff 8/7/2018 8/7/2019 Lot Size in Sq Ft: 95481 Total Bedrooms: 3 0 Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 10A� ro The Engineer needs to test hole prior o the construction of the septic field. Construction may proceed at your own risk befo e 7 day water monitoring is complete. Please submit stamped and signed results with the As -built Inspoetron Report. If the results require a design change, construction of the system will stop pending On -Site iew and approval. Received Issued By eqo/-�' �/ 10 cc Date: Date: % g Municipality ®f Anchorage P.O. Box 196650 0 4700 Elmore Road Anchorage. Alaska 99519-6650 ® (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.orq/Onsite Development Services Division On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW xxxx Waiver#: OSV181053 COSA#: Permit#: OSP181222 PID#: 050-631-02 Legal Description: Mountain Valley Estates B3 L2 Engineer: Pannone Engineering Services Applicant: Robert Sundberq Your request for a waiver of the required 50 feet horizontal separation from the absorption field to the excessive slope has been approved. The approved separation distance is 29.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: 9/6/0 Approved by: 4, . Name of Rev'- er **** VARIANCE/WAIVER REVIEW **** jus MUNICIPALITY OF ANCHORAGE - r :7".4 411111111111111111111111 Community Development Department p Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water& Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 050-631-02 Property owner(s) ROBERT SUNDBERG Day phone Mailing address 1801 STANTON AVE, ANCHORAGE AK 99508 Site address 5050 HILAND RD Legal description (Sub'd., Block & Lot) MOUNTAIN VALLEY ESTATES B3 L2 Legal description (Township, Range & Section) Lot Size 95,481 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (0 all that apply) Absorption Field C Initial [ Single Family (SF) n (w/wo ADU) Septic Tank ❑X Upgrade ❑X Duplex (D) U Holding Tank [I] Renewal ❑ Multiple Dwellings Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. TSignature of property owner or authorized agent) Permit/Rush Fees: 5106 Waiver Fees: *2.16 Date of Payment: IALI 117 Date of Payment: s/i/i Receipt Number: 8/a94 n Receipt Number: O 5) 090 Permit No. OSPI d I g9-2 Waiver No. O 5 V 1 ' I Permit App__•'•" c: Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com 29 August 2018 Subject: MOUNTAIN VALLEY ESTATES B3 L2 Upgrade Septic System Permit Request Design Narrative This is a design narrative to issue a permit to install an upgrade septic system for this property. The system will serve an existing three (3) bedroom house. This lot and the surrounding lots are served by a private wells. There are no wells within 100' of the proposed septic system. 1. Soils. One test hole was performed on the property on 1983 to 13'. PES performed a test hole in June 2018 to confirm the soil strata of the 1983 test hole. Due to nature of soils a perc was not performed due to sluffing of sides and danger to engineer and a sample was taken, based upon the existing system location/depth and the comparable soil strata PES is using the visually rated soil absorption rate and "slowing" it to 16-30mpi absorption rate. Ground water was not observed to a depth of 8.0' below the surface after the seven day monitoring period in the PES test hole. Bedrock was not encountered in the test hole to 8.0. Based on the results of the sieve and overall soils appearance, an application rate of 4.0 GPD/SF was used for a CATIII AWWTS wastewater system in the area of the test hole. Upon beginning excavation of the existing system we discovered the system was placed atop bedrock at 8.0'. As a result we are going to create ERS to install the system. We are going to further reduce the absorption rate of the receiving soils (horizontal conveyance) to the 31-60 minutes per inch (2.0 GPD/SF) which will require an absorption area of 225SF. Using 2.0' of MOA Type II and 2.0' of Sand and a length for the ERS of 29LF that provides over 232SF of absorption area. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The existing topography on the lot generally slopes from East to the West. The proposed field is to be installed 50+LF from a grade break that is over 25%. 5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On -Site Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Pannone, P.E. Owner/Civil Engineer Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 NOTES & SPECIAL PROVISIONS: NOTES FOR CONSTRUCTION 1. SCOPE AND SPECIFICATIONS: i 1 1.1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55. SEPTIC I I I AREA M I I 1.2. SCOPE OF WORK: INSTALL NEW 1500g ADVANTEX TANK, AND SOIL ABSORPTION SYSTEM. 1.3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 8 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 8 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. 1.4. STRUCTURES DEPICTED ON THE SITE PLAN ARE BASED UPON ONE OF THE FOLLOWING: CONCEPTUAL PLOT PLAN DEVELOPED BY OWNER; A PLOT PLAN DEVELOPED BY RLS; OR A SURVEY AS-BUILT. 2. CONSTRUCTION SPECIFICATIONS: 2.1. ALL EXCAVATION DEPTHS ARE ADVISORY. THEY ARE TO BE VERIFIED AND MAY BE MODIFIED BY THE ENGINEER IF ACTUAL FIELD CONDITIONS VARY FROM THOSE USED TO PREPARE THE DESIGN 2.2. EXCAVATE THE DRAIN FIELD. BOTTOM OF EXCAVATION SHALL BE LEVEL AND SCARIFIED. RECORD ELEVATIONS AT BEGINNING, MIDDLE AND END OF TRENCH BOTTOM. CONSTRUCTION EQUIPMENT SHALL NOT OPERATE ON THE FLOOR OF THE EXCAVATION. ANY MATERIAL COMPACTED BY THE OPERATION OF THE CONSTRUCTION EQUIPMENT SHALL BE REMOVED AND REPLACED WITH UNCOMPACTED MATERIAL. 2 3 E THE SEWERCONTAMINATE SEWER ROCK WITH NATIVE MATERIAL OR SPOILS FROM EXCAVATION. LEVEL ROCK TO OC TOR TO INSTALLING THE PERFORATED PIPE. 2.4. ALL PIPE SHALL BE PVC CONFORMING TO ASTM D3034 OR ENGINEER APPROVED EQUAL. MINIMUM SOIL COVER SHALL BE 3 FEET OVER THE PIPE AND 4 FEET OVER THE SEPTIC TANK. ONE INCH OF INSULATION MAY BE SUBSTITUTED FOR 1 FOOT OF SOIL COVER.\\ 2.5. ALL INSULATION SHALL BE 2" THICK DOW HI-40 INSULBOARD OR ENGINEER APPROVED EQUAL. CENTER INSULBOARD WIDTH OVER SEPTIC TANK OR LINES. 2.6. GEOTEXTILE SHALL BE MIRAFI 140S OR ENGINEER APPROVED EQUAL. LAP ALL JOINTS 2 FEET MINIMUM. 2.7. COVER THE DISTRIBUTION PIPE WITH A MINIMUM OF 2" OF SEWER ROCK AND COVER WITH GEOTEXTILE BEFORE PLACING INSULATION AND BACKFILL. 2.8. MATERIAL USED AS FILL SHALL BE CLEAN AND FREE OF ORGANICS, TRASH AND CONSTRUCTION DEBRIS. 2.9. SLOPE ALL FILL MATERIAL TO DRAIN AT 2% MINIMUM SLOPE AND 3:1 MAXIMUM SLOPE AND IN SUCH A MANNER THAT PONDING AT OR NEAR THE DRAIN FIELD DOES NOT OCCUR. THE FILL SHALL BE LEFT AT 6" HIGHER THAN SHOWN TO ALLOW FOR SETTLEMENT. SEED SURFACE AFTER COMPLETING INSTALLATION AS PER MOA CODE. 2.10. RECORD THE FINISH GROUND ELEVATION OVER THE BEGINNING, MIDDLE AND END OF SYSTEM. 2.11. MAINTAIN 5' SEPARATION BETWEEN PERCOLATION HOLE AND THE DRAIN FIELD TRENCH. 2.12. EXPOSE, PUMP AND FILL LOG DISPOSAL CRIB OR CONCRETE TANK WITH SOIL TO ABANDON IAW WITH MOA CODE IF NEEDED. 3. CONTRACTOR RESPONSIBILITIES: 3.1. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK. 3.2. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED. 3.3. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES. 3.4. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE ENGINEER. 3.5. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN.ABSORPTION 3.6. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED-LINE AS-BUILT DRAWINGS TO THE ENGINEER. THE RED-LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND TANK ELEVATIONS. 3.7. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN-OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING. 4. THE CONTRACTOR SHALL SIGN THE FOLLOWING: I CERTIFY THAT ALL WORK WAS PERFORMED IN ACCORDANCE WITH THE APPEND PERMIT, AND ANY AND ALL CHANGE ORDERS, AND THAT THE AS-BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED. CONTRACTOR: BY: TITLE: DATE: 1 \ \ \ \ \ \ \ \ \ \ \ \ \ \ C v \ 1 \ I \ \ \ \ / I I TRUE NORTH SCALE 1"= 50' \ \ \ 1 \ \ \ } I \ \ I \ \ \ \ \ I WEL I I \ \ `1 I \ \ \ 1 I y I 1 \ I I \ c0 \ \ \ I INSTALL150OG ADVANTEX TANK Z REMOVE SEPTIC TANK E ��^N \ \ W/ AX20 POD(P PER MOA CODE O—A \ \ �I I '1 I I II I I I I I I I \ \ \I \ 1\ SECSION P,{. I // I I I 3BR I I I %� I I I 1 I I I SFD _, . \ \ 1 10.7 I / \ I \ ( ( \ \ \ \ I I I I I 1 \ I vV l \ TH-1983 \ I \ 1\ \ \ I �V I ` \ \ \ \ REMOVE HATCHED PORTION OF I 1 TN-P I \ FIELD TO CREATE 6' \ I \I \ \ \ I \ SEPARATION AND REMOVE BIOMAT \ I 126 , 2 \ \ \ \ MATERIAL (P) INSTALL 2.0' MOA TYPE II \ /C / I \ I \ IN EXCAVATED AREA ABANDON \ REMAINING PER MOA CODE \ I I \ \ \ \ ,61s 10 1 1 \ 1 1 1 0 \1 \ \ • \ INSTALL ABSORPTION FIELD P 24.OLFx 5.0'Wx0.5'EDx4.0'TD 1 / o I = I\ \ 1620 1 \ W/COs & MTs AT ENDS. INSTALL ERS (2.0' MOA 1 \ ��9 1 3 I \ 16zs �\ ' TYPE II, 2.0' SEWER SAND BENEATH FIELD) SEE ` \ y 1 11630 \ \0 \ I DETAIL THIS SHEET. \ \ \ \ \ \ \ \ \ 64\ 163s\, IIQ\ I DETAIL t6as \ 1 �I Q \ I / 1 I 1 SCALE: 1 "=10' �� \ \ \ t 1 \ \ '` l O ` \ \ \\ 1 \ I / I 5 \ $ 3 4 2 2'0 �� \ \ \ \ \ \ �\ \ ` \\I\ (� �' SAND I I \ \ \ \ I I I �l \ \ ABBREVIATIONS I \ \ \ \I 1 \ TH TEST HOLE MOA TYPE II a�wu °V•` 1 SEI4TIC I1\ \ P PROPOSED \ \\ 'BEOROCR \ I ( ) STING 2.0 \� ARE W _WATER LINE /1WELL RADIUS CO CLEAN OUT N0. 1 1 MT MONITOR TUBE NO. — SS NEW SEPTI MT TYPICAL o � m w p < moo Z ¢ Moc N M m W z I- C Q Q I- Z J Hi W >_ W O A La �_ lin � > a- Z LU I- W Q H (`) Z C 2 PRIMARY/RESERVE DESIGN PARAMETERS PRIMARY DESIGN PARAMETERS 1 2 3 4 5 6 7 8 9 10 11 12 13 TEST HOLE SOILS LOG: 1 0 v ^�� W - Z O W LU a N N Z Z V ^^ Z — a W y o e oR TOPSOIL READING DATE NET TIME WATER LEVEL READING NET DROP MPI (MPI) GM NO. BEDROOM: 3 450 ( 9Pd) PERC RATE: USETANK SIZE: O96 ADVANTEX CATIII SOIL RATING: 4.0 GPD/SF AREA ROD: 112.5 SF SYS. TYPE: WIDE TRENCH 0.5'ED MIN LENGTH: 22.5 LF USE: TOT L AREA: 120 E.D., Tr� TOTAL AREA: 120 SF // P�C Pw r SILTY GRAVEL &SAND 1 04JAN19 8.396' 3 SEE RECORD SOILS LOG & SIEVE ANALYSIS 03 SM/ML 4 0.3 5 P .: •�; �y�. jo: I �►0 SILTY SAND 6 1.5 MIN 11.900" 3.79" 0.4L &CLAYEY FINE SAND WAS GROUND WATER SOIL TEST RESULTS /ANALYSIS ENCOUNTERED? N PERCOLATION RATE 8.5 (minlinch) (Hydrologic Soils Group: HSG A) IF YES, AT WHAT USE 16-30mpi DEPTH? —NA—' PERC HOLE DIAMETER 6" • TEST RUN BETWEEN 5 FT AND 6 Fr DEPTH TO WATER AFTER TEST RUN FOR OVER AN HOUR, MONITORING? - NA - LAST THREE READINGS PROVIDED. DATE TEST TO CONFIRM SOIL PROFILE ORIGINAL TEST BOH — — — — — — — — — — — — — — — — — — 1645 _ _ _ = — — — — — — — — — — — — — — — — — — — — — — — — — 1640 _ 8.3 —11wTnc� ——`—�� �yscq \ — — — — — — — — — — — — — — — — — — — — — — — 1635 REVI IONS' REvl:aauLZD1R REV2:04AUG2018 C01: 29AUGM111 HOLE TO 13' (NO H2O) PERC RATE BASED UPON SIEVE AND USING 16-30MP1 ILO 1505F/BR DATE PERFORMED: COMMENTS: Test hole excavated byJR'S. PERFORMED BY: Joseph Lawendowski. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL — — — — -- 469 — — — — — — — — — — — — — — — — — — — — — 1630 — _ SECTION' — — _ CTR— — — — — — — — — — — — — 1625 SCALE: 1 "=20 �, N (� F1 — — — — — — — — — — -SFJ — — — — — — — — — — — — — — 1 620 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1 610 �! oN �V ° GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. 29JUN18 a� 2 iN u3 ` SHEET C3.0 1OF1 040.003 Crowther Associates Client: Pannone Engineering Services Projects: 5050 •ligirl n ( .C;t.AC/: Date: July 2, 2018 Particle Size Distribution Table Percent Passing Sieve Size Sample Source Sieve Size 3 inch 100% 1-1/2 inch 97 3/4 inch 32 #4 58 #10 49 #40 36 #100 26 • #200 24 0.02 mm - - Classification Silty Sandy Gravel (GM) 1632 Bellevue Circle/Anchorage. Alaska 99515 Telephone(9071 349-3198/E m ail:crowllre r Aalaska.ne i • MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the"AGREEMENT" made and entered into as of this 25th Day of July of 20 18 , by and between Robert Sundberg . herein the"OWNER,-and the Municipality of Anchorage,herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein,the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as /veto /2 cD3 / -thui 1 ?c, -1;2- c, , -.T -1Ein/ located at (legal description)) _S,...5/yt1_ Mountain Valley Estates Block 3, Lot 2 (5050 Hiland Road, Eagle River, AK) 2. Maintenance,Repairs and Alterations. Owner is required to read, understand and initial each section) Throughout the term of this Agreement,the Owner shall enter into a service agreement +\ with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance.adjustment(s), replacement costs,and inspection costs. This includes an annual maintenance fee (typically$400 to$600). /V_ Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield i replacement. (rev. 05/18/2018) Page 1 of 3 .1 +�� Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. t, , Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be i assessed in accordance with AMC 14.60.030. g_ Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. igOwner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On-Site Systems Approval. (ryi Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction,maintenance and repair of the Owner's AWWTS. 00, Owner agrees to maintain remote monitoring of the AWWTS as required by the A W WTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system,or upon transfer of title,and shall continue V+hile the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof. or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. f w 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. I (rev. 05/1812018) Page 2 of OWNER: 4 1 07/25/2018 By: A: ,' /h. (signature) Date: Robert Sundberg (print name) STATE OF ALASKA ) )ss. THIRD JUDICIAL DISTRICT ) The foregoin instrument was acknowledged before me this'2 i"day of ,, .,,.\vl , 20 , by ,,c:y , .:_ {) Sv..,.d4�Y i ) ``` w 11111//4 �‘ \N SH/4A ,,, NOTARY PUB OR ALASKA ��� �..•••' �� My Commission expires: k A-- Q V - 2(! (g A. .. ••• �� �0' AR1- •: it • _ .....•-, • iz. % '°UBS-0 : cr %(S ••••• '...‘""P '4 j�E MUNICIPALITY: /,• "O"F• ,\. ��� il a By: 1 (signature) Date: y D2v fee, cenci.y2 (print name) Title: . • (rev. 05/18/2018) Page 3 of 3 8476P I LOT 1 I N75-01 I I 75 13,42„ 444.44 I . I o Well I CD O o co 30 Co 2 (N m. I. 0 O O ..L. • N Q 34.2 c y Za N MIz. M DoWM • m �a (Ni ° Z m � . N CD Z LOT 2 co o m ° co J co c`to ° Coo 3 coO o ° � O Chugach co fill N. / 0) State Park 34.2 °o I Cr • 143. �r44. OF A , 11 • N... % /.0!• : 49th /\ I • C 2 / Elizabeth L. Walatka: s I ^�`�0i N II srF• 8036 - LS ••yJ��� N75°13'42., 13 J " �6 4pg 68oo / AS-BUILT NO CORNERS SET THIS DATE II hereby certify that I have performed a Mortgagee's inspection I M of the following described property: LOT 2. BLOCK 3. CD MOUNTAIN VALLEY ESTATES LOT3 CO / Anchorage Recording District,Alaska,and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying 30 adjacent thereto,that no improvements on the property lying adjacent thereto encroach on the premises inh question and that there are no roadways,transmission lines or other • ••••• ••••••••••••••••••• •• • ••••L ' tseiiblts on said property except as indicated ryhereon. EASEMENTS OF RECORD,OTHER THAN when existing overhead power 8 tele,lines are reDated at Anchorage,Alaska THOSE SHOWN ON THE RECORDEDSCALE: 1��= 40' this 2nd day of AUGUST ,2018. PLAT ARE NOT SHOWN HEREON FRED WALATKA&ASSOCIATES,L.L.C. UNLESS OTHERWISE NOTED. Engineers and Surveyors FB 18-7, pg 15 BE 907-248-1666 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE [~"N EW MAILING ADDRESS ~.O. ~c~/ //~/~ LEGAL DESCRIPTION . ~d/~, ,P. 7' NO. OE BEO.OOMS .5 Dr ., PERMIT NO. ~',.~ / g) 2,~ DISTANCE TO: Well Manufacturer [Liq. capacity in gallons IF HOMEMADE: DISTANCE TO: Well 9fade ~ I Type of crib ~ib diameter DISTANCE TO: Well Class~ Depth DISTANCE TO: Building foundation Absorption area Dwelling ~.~ t ~ I Material Width Inside length Liquid depth Dwelling PERMIT NO, Material Liquid capacity in gallons Foundation ~)l Nearest lot linetT~, Total length of IjRes Trench width Distance between lines 12.25 Material beneath tile I~ ~ inches Depth Crib depth No. of compartments Total effective absolption area PERM T NO; Total effective absorption area Building foundation Nearest lot line Driller Distance to lot line PERMIT NO. Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS ~ SOIL TEST RATING INSTALLER DATE LEGAL Jv..~o .~ LOT £ ~c.,( ~, ,'.,lo,4,,~¢,~,',-, Vqlle,.j ~.. 72-013 (Rev. 3/78) [::,EI:::'F!I;:"I"HEI'.,IT OF' HEFII....TH FII'.,IE;, El,l,, [1-_l',lllbl,llPl E:;;'~~ '" L. '" :~F'r'I:;;:EET., FBNCI-IOf;'.FiGE., F::lk: :~'~ "5 ;:~ :i.. ;~h~,~.-.'.,::i.7;~:E~ : F:Ii'.,IE:HOF~I:::iGE~;:~,~1...~2:~.:~:::1.. : EF:IGL. E ~: ]: ',,,'ER ...... ~"-.,~ .......... :::~ % "T" lEE :~E; E: ~..,,-~ I~E ~:;;~:: FIF'F'i.. :1: CRi'.,!T: L. · ul ,I:, COI'.,i:STF:. F'HOi'.,tE: EI:::IGLIE R :[ ',,,'lEI;L, RK :~'~:~1'7';:~' L..tEGI::IL. [::,E:~i;CR :1: F'"I" :1: ON ~;I...IE:i::, :[ ',,,' :t: :~; :t: 0t'.,I: H"I"I'.,I ....... ' ... , HI,..LE. r IE?'['. E:L. OCK: :ii: I.,,.OT: ~:, i....O"t" ."; :1: ;;':rE SE;:~i:,':I.E; ~;(;:!. FT. "f'Eq.,.tI",!:SH :1: F': :J..4,1",t t"IF~;:.:; ]: I','ll...iht N ... FIE F'F' ()F' IE:Er:,ROOH:5 ::~: :~;(:) :[ L I;:R"I" Z I'.4G ' _ ,~ ::: :L.::: I:: ::t. 51;~) :~..SE~ ,:: ~;~]:~. I:::'T. ,'"F F'" I... ]: :~F'i"EI:::, Ed~]:L. OH RRE THE OF:'T ]: 01'-~5 F¢,,,'F:I :[ L. FIE~LE: TO '.r'OU :[ 1'.,t I)EZ]; :l: GN :1: NG '.r'OI...l~;: ~;EF'"I" :[ C '~;'T':% TEH CHOOt~SE THE OF'T :[ ON TI'"IR'I" IE',E:FST F ]: "F:~ "r:OLff;~: H :I:[::'TH = 2. 5 FT. t.I.II,[:.L DEPTH ........ :1.. E~ F'T. GF:FI',,,'EL ',,,'F [ _ HF' :=: 2:% 7 CI...I. "¢1~:"5. TFII"41'::: :E;:[ZE = ::L., ~.;~;~. ~;~t GRLLON:E; ,::"l'l.,.JO J::::OHF'FIRTr,'IEN'r' "FFd",!K', L. IENGTFI =~ ::~:::',EL ~2:.~ F'T. GF:FI',,,'EL DEF:'TH ..... EL ~5 FT. GF4:(:i',,,'[~:I~...","'"J... J'E;. ~= ;;~:[~;. 7 Cl..i. [ .:'"',. "FF:INF::: ~5 '.[ ZE = ::L., EiEi~:.h EJ GF:ILLE~N:~5 ,:: "l"l.,.JO E:Of"tF'RF]:'f'HEhI"I" I.,.I:I:I:::,TH ,'.= 5. EJ F'T. TOTRI.... DEF'TH .... 7'. E~ FT. GI;::Ft',,,'IEL DEF'TH ~:: ;2:. ~2) t:::'T. GRFIVEI.... ',,,'Oi...LII"IE; ::= ;;;~'.;Sh ::i. E:U. '¢i)'.E;. 'TI::II'.,II.,:; :~; :[ ;;~:E ..... ::!..., ~;~JEJl;~J. t;~l Gl:ll...LE h,t'.~; ,:: 'T~,.IO COI"IF'FIR'I"I"IE:I",IT "r'FIhlK ', ]: F E}~'."[' :[ F'"r' 'T'HFI"[': :i... ]: FIH F'FII"'t:[L.:[FIF~: t.,.I:[TH THE: RE6¢J:[I:~:EI'"IENT:~; F'OF: ON'-:SZTE :~IEt.'.IE:R~; I:tNE:' HEL.L2~; R:5 SSE"t~ FORTH E¢¢ "i'HE I',ILII'.,I]:C]:F:'FiI...:r."I"'¢ OJ:::' I:;:II'.,E:HEIF;:RGE FIl'.,IE:, THE ,:~:. ~ t.,.I:I:L.L. ]:I'.,I:i~;'T'FIL.L. THE :E;'¢:~;TE:H ZI'.~ FIE:CORE:,FII'.,ICE I.,.I:[TI'I THE CODEr5 I::11'.,1[::, HFI',,,'E: F;:ECE;[',,,'ED F:I E "'F:".¢ OF' 'T'FIE: E:O[::,E ::: I,It,'11::1~'¥ FIND I'.):[FIGF;:Fli',I FFI"TI::ICHHEI'.,IT~5 [,.IFIl:CH ~:~; F:'I:~tT OJ:::' "I"H;I:'.~ F'EF:H Z T. ]: LINDEI;;:~"I"FII'.,E:, THFtT THE ON..-dS:[TE :~51EHEF;: :~;"r':~;TIEH I"II::t'T' F:E(;i J;[RE: IENLI::I~:GEt"IENT ~F:' THE F'E:~;:H ]: T FII::'F'I... ] CRIq'I" HR'.5 "I'FllE F' :~'::SF' '" I'-E: Z EJ Z L :[ T'T' T() THE Zi",I:STF:IL.I...FI'T'[r:N ]:t",I:SF'E:C'T:I:Ed",IS OF F:li",l'¢ I.'.IE:L.L:~; RD..TFICENT TO "f'HZ:E; ~F', ........... FI:F1 FINE:' THE I",IUHE~ER FF RE~;]:i;::,E~i",ICE:~; ThIFJT THE: I.,.IELL. H]:L.L.=,E.F.,-' '"'""' ):F R L.:[F"~' :~;TWr']:Oi",t :[~; ]I"4STF~L.L..E:[::'., FIN EI....ECTF:]:E:FJL. F'EIr4:I'"IZT I:lh,JJ) ]:N:~;F'ECT]E~N I'"IU:ST /1 ~RFO~MED FOR~ LFGAL DESCRIPTION: 1 3 4 5 6 7 8 10 11 12 13 14- 15- 16 17, 18- 19- 20 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Streat, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST /7../ SOl LS LOG [] PERCOLATION TEST SITE PLAN WAS GROUND WATER ~/~'~ I~ ENCOUNTERED? O P E IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE (minutes/inch) COMMENTS TEST RUN BETWEEN 72-008 (6/79) FT AND FT :1 o d i( I/o j /!:; ! 4 Tom Fink, Mayor N unicipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 December 13, 1988 Robert A. Shafer, P.E. S & S Engineering 17034 Eagle River Loop Road Suite 204 Eagle River, Alaska 99577 Subject: Waiver Request for Lot 2 Block 3 Mountain Valley Estates Subdivision Waiver Request ~WR88-072 Dear Mr. Shafer: Your request for waiver of the required 100 foot separation of a septic system -to a private well has been approved. The approved separation distance is 94 feet. This waiver approval applies to the existing septic system to well separation only. Any future upgrade to either will require all separation distances be met or another approval from this department. Sincerely, Daniel J. Roth Civil Engineer On-site Services DJR/ljw~6 ROBERT A. SFIAFER November 25, 1988 OIVIL ENGINEER 694-2979 HEALTH AUTHORITY APPROVALS SEWER &WATER MAIN EXTENSIONS SEWER &WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELLINSPEOTION & FLOW TEST SITE PLANS ROAD OESIGN SOIL TEST PERCOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ON SITE WASTE WATER DISPOSAL SYSTEM DESIGN Municipality of Anchorage Department of Health and Human Services 825 L Street Anchorage, Alaska 99501 REFERENCE: Lot 2; Block 3; Mountain Valley Estates Request you grant a waiver for the horizontal separation distance between the private well and the septic tank located on the referenced property at a distance of 94 feet. The well was drilled in March, 1983. The septic system was installed in December, 1983 under permit #831020 and inspected by a private engineer. A risk analysis has been performed and it appears that no bacteriological pollution is possible from this source. Attached for your review are the following documents: A. Satisfactory coliform and nitrate analysis results taken from the well located on the referenced property. B. A plot plan showing the relative distance between the well and septic system. C. Risk analysis waiver review worksheet. D. The well log for the referenced well. It is our opinion that the horizontal separation distance prescribed by 18AAC72.021 is not required in this case. If you/jc~re additional information, please contact us. S%n~erely, ~ P.E. 17034 EAGLE RIVER LOOP, SUITE 204, EAGLE RIVER, ALASKA 99577 SCALE fby DO-C Co. dDa SULLIVAN WATER WELLS P.O, BOX272, CHUGIAK, ALASKA 99567 · TELEPHONE 688-2759 OWNER OF LAND >~ " · ~ ' J :;~ ":' ] STATIC LEVEL OF WATER FT. ADDRESS LEGAL DESCRI~ION DATE - Started PERMIT NUMBER KIND OF CASING _ KIND OF FORMATION: From.~ Ft. to From__Ft. to . ,, From ,i / Ft. to ~,"':~ From ; ,- Ft. to From Ft. to-- From: ;:' i Ft. to From/ ,] 4 Ft. to From__ Ft to From ;, ~ , Ft. to From__.Ft, to From.__ Ft. to__ From Ft, to-- From Ft. to___ From Ft. to Frmn__.Ft. to From __ Ft. to___ From Ft. to ,, ' '~' )< From__ · Ft, t/&'t/t:i~' ;~ < +t,. /..<..'? From__ Ft. ex; ,~,'7,,: ? ':<-, ?-", '~ :, ,'-L~ From~ , Ft. ~:5: ~9~ :~ t ~ ~ / ' From ~ Ft. ? (:~t , From From Ft. From__ Ft. From Ft. From__ .Ft, From Ft, From_ Ft. From__ Ft, to -Ft. Ft. to ..... Ft Ft. to__Ft Ft. to Ft Ft. to__Ft, Ft. to Ft Ft. to Ft Ft. to Ft Ft, to Ft. Ft. to__Ft .Ft._ From Ft. to Ft. Ft From Ft, to Ft. MISCL. INFORMATION: DRILLER'S NAME SCALE