Loading...
HomeMy WebLinkAboutMOUNTAIN VALLEY ESTATES #1 BLK 5 LT 11Mountain Valley Estates #1 Block 5 Lot 11 #050 - 661 - 14 I i nil -I cy � � c., DOC CO dba MALL S- COL. U L", L IJ' VA, N V M E R k' W 1. 111 S ' 02 = P.O. Box 670269, Ghugiak, AK 99567 600-2750 OWNER OF LAND: Brent Little ADDRESS: Bore Hole Data Depth From To LEGAL DESCRIPTION Mountain Valley Estates #1 B5 1-11 DATE: 7-26-18 0 2 PERMIT NUMBER: OSP181217 DATE OF ISSUE: 7-26-18 TAX IDENTIFICATION NUMBER 05066114000 Is well located at approved permit location: ®Yes ❑No Method of Drilling:. ®air rotary ❑cable tool Depth of Well: 164' Casing Type: Steel Wall thickness .250 inches Diameter: 6 inches, depth 158 feet Liner type Static Water Level: 65 feet Recovery Rate 5 ® gpm ❑ gph Method of Testing Air Well Intake Opening Type: ® open end ❑open hole ❑ Screened Start feet Stopped ❑ Perforations Start feet Stopped Grout Type: Bentonite Volume: 50 lbs Depth: from 2 feet, to 42 feet Well Disinfected Upon Completion: ®yes Ono Method of Disinfection: Chlorine 50 PPM Comments: 2 4 4 21 21 42 42 101 101 115 115 156 156 164 Casing Stickup Overburden Tight Silty Sand & Gravel Hardpan & Clay w/ Boulders Clay & Gravel Hardpan Wet Hardpan w/ Clay Yellow Bedrock Yellow Broken Drillers Name: Cole Sullivan ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. Municipality of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough: Department of Environmental Conservation. ARCTIC PUMP & WELL INC. Jim Sullivan PO Box 770197 Eagle River, AK 99577 skits E SE�BYIla �'mil� (907) E88-2510 t ~ (907) 243-2282 Well Drilling Permit Number: osp181217 Parcel Identification Number: 05066114000 Date Of Issue: 7/26/2018 Legal Description mountain valley est #1 B5 L11 Property Owner Name Address: Keller Construction Lot: 11 36784 Eklutna Lake Road Block: 5 Chugiak AK 99567 Pump Installaion Date: Pump Intake Depth Below Top of Well Casing Pump Manufacturer's Name Pump Model: Pump Size: Pitless Adapter Burial Depth: Pitless Adapter Manufacturer's Name Pitless Adapter Installer: Well Disinfected Upon Completion? Method of Disinfection: Comments: Pump Installer Name: Arctic Pump & Well, Inc. Wednesday, Fcbruaiy S, 2020 5/29/2019 110 Franklin 5Y 10SDQP-1.5HP-3RC 1.5 HP 10 B-10 u/k Yes Chlorine AnmlllI T bvillPAW & 1b5UL;lK-ch6 LAND SUKVEYENG 694^U8Z9 I HEREBY CERTIFYTHAT1 HAVE SURVEYEDTHE SCALE: FOLLOWING DESCRIBED PROPERTY: y /��✓✓�r��'/�/ Y,;>G !%��/fJ,Q.Jp ��oT/l BSS ' AND THAT NO ENCROACHMENTS EXIST EXCEPT AS DATE= INDICATED. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY GRID: EASEMENTS, COVENANTS., OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDI- VISION PLAT CINDER NO CIRCUMSTANCES SHOULD FB: ANY DATA HEREON BE USED FOR CONSTRUCTION OF FENCE LINES, OR FOR ESTABLISHING BOUND- Dr2A�tN= ARY LINES. Q Al LHJ Y.. A ,. si0000D •...J • Duane Merk Seward ��. LS - b 3 0,c,'""`."r0p MUNICIPALITY OF ANCHORAGE On-Site Water&Wastewater Program `�� y A :,>'S� PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone: (907)343-7904 Fax:(907)343-7997 t http:/lwww.muni.org/onsite `' '," a', Dcpartmcni 4M1'CHORPOE On-Site Water System Permit Permit Number: OSP181217 Effective Date: 7/26/2018 Work Type: Well Renewal Expiration Date: 7/26/2019 Tax Code Number: 05066114000 Site Legal Address: MOUNTAIN VALLEY ESTATES #1 BLK 5 LT 11 G:0758 Site Mailing Address: Owner: LITTLE BRENT Lot Size in Sq Ft: 75072 Design Engineer: NORTH RIM ENGINEERING Total Bedrooms: 4 This permit is for the construction of: ❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy Q Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: To close out this permit, please submit the following: 1. Well log 2. Pump install log 3. Water sample results for total coliform, nitrates and arsenic. 2(.7/e Received By: J �0 Date: Issued By: �Q�1`I%iCf°A ���r�V Date: Z 6 • MUNICIPALITY OF ANCHORAGE Development Services Department 'Tv Phone: 907-343-7904 On-Site Water & Wastewater Section _ Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. cf 50 —Col Property owner(s) � 3�-�`L' Day phone (62-2:---a2-92 Mailing address 37.3c- g.- r-4- oJJ D72 Site address Legal description (Sub'd., Block & Lot) ^AMA VAL( T/ X57, -47 X35 Ll Legal description (Township, Range & Section) Lot Size X51(''?Z Sq. Ft. Number of Bedrooms & APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) TE] (w/wo ADU) Septic Tank ❑ Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well X❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. 11116 (Signature of property owner or authorized agent) Permit/Rush Fees: d I 0 Waiver Fees: Date of Payment: Tl231143 Date of Payment: Receipt Number: Receipt Number: Permit No. C6131912-11- Waiver No. G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc IV Zit�,o-7.lCit ?tea S `. `� C,ec.4-c-rte-•-/ - CD — --` / '' AS-BUILT MEASUREMENTS zo-zsz (3.e �/ m-. \ Power Pole Tree C j• � ' ,n DC01 162 50 / ST1 157 52 ST2 147 54 Proposed Z r',� DC02 142 55 / Well —{ (),\„,,, \ CO 92 96 s` MT/CO 168 27 Proposed a House I 0 100" 4 Bairn /17;< DEVELOPED 0S fBLOCK 5, LOT 10 L 20-25% A ,Qo zo-25% �O/ / New 1500 Ilion ��--� Civ, y Septic Tank ; / FCO / 701-.---41 DCO DC❑ / �� � C❑ '���MT/CO Septic W rn— 19z Area Q T.-- 0 ---Tree \ , / 1`7� / Rv —��4 is-zoz `l� / 15-20% Drl1"eWOy l O _� 11 11 11 1 III Birdsong Drive \ 6'-8' Cut-Bank To Be Graded Under 257. Power Pole----..-- ole NORTHRIM }--���.... .. ENGINEERING ENGINEERING � ;P49•ai `�*++ NEW SEPTIC MOUNTAIN VALLEY ESTATES #1 SteveEng.com . SYSTEM (4 BDRM) BLOCK 5 LOT 11 PO Box 770724 ' t: RECORD Eagle River, Alaska 99577 ++ -arse g 907 694.7026 N 2 f PLAN VIEW Date: wn By ca 2/22/18 ' SE ISls:1, = 40 , I SHEET: 2 of 4 « (Rev 05/02/18) Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP151072 PID Number: 05066114 Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑ Upgrade Name Brent Little ABSORPTION FIELD ❑ Deep Trench FE] Wide Trench ❑Bed F-1 Mound Site Address 3730 Birdsong Drive ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 276-6664 77LEGAL 4 1.2 GPD/SF 2 Ft. DESCRIPTION Depth to pipe invert from original grade 0.5 Ft. Gravel depth beneath pipe 1.5 Ft. Subdivision Block Lot Mountain Valley Estates #1 5 11 Fill added above original grade 4+ Ft. Gravel length 85 Ft. Township Range Section Gravel width 5 Ft. Beds: Number of Lines - Distance between lines - Ft. SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 545 Ft2 1 Ft. Well 1001+ 100'+ na na 25'+ TANK ❑® Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity Anchorage Tank 1500 Gal. Surface Water 100'+ 100'+ na na Material Steel Number of compartments 2 Lot Line 10'+ 10'+ na na NA Foundation 10'+ 10'+ na na LIFT STATION Manufacturer Capacity Gal. Remarks House Not Built. 100'+ Measured To Stream Alarm location Electrical installed by PIPE MATERIAL House to tank none drainfield Tank to D3034 Installer Homeowner Drainfield D3034 CO/MT D3034 Inspector BENCH MARK (Assumed elevation) 100 ft Inspection15' 2/10/18 2/21/18 Location and description dates:2 Nail In Tree 3rd 3/26/19 Wh ON-SITE WATER AND WASTEWATER SECTION APPROVAL EngingersStafnp rc Conditional Approval: Date y E. 3 fb Septic System Approved Date Note: this approval does not include well permit requirements. (Rev 05/02/18) r - C:) Oj Nr U-) � cu LO Lr) Lr) Lr) ON CL (U r, I'- CU (U CC) 1,D Lr) 'q- 'W GIN %,D 0 C) 0 F— Lij ln 0 C) N II n 0 X Lr)x 0 (L) z V) cu V) ui mL I N 0 -i N .1 LAJ 0 N >O LLJ -j n m E3 CU u 0 (U 0 N, U � uo A(4 C4 P u M: 30 DRAINAGE EASME"' >IJ'Od a�pqS 441174(12 ---- 101 M Id m X cu N L 0) ar LO 04 0 -Y 04 4 - ZD O CL 0 (U L I to 0 CL 0 C) 0 F— Lij ln LLJ -.-i C) N II _j ---I X Lr)x 0 (L) z V) cu V) I N N .1 CPI N Cl) >IJ'Od a�pqS 441174(12 ---- 101 M Id m X cu N L 0) ar LO 04 0 -Y 04 4 - ZD O CL 0 (U L I to 0 CL k6- - - a a LLJ P Z LLJ LLJ x -K 0 co z z 0 (4- 0 cu Lij LLJ -.-i C) N II _j ---I > w F Ln U -I F D F -I U -I 1 LLJ CPI F M n/ Cl) k6- - - a a LLJ P Z LLJ LLJ x -K 0 co z z 0 S U Q1 L dS y d U -P n o, aio, 3 P4 Ln -P O L d Qi Ln U M Ln ON O) r<C o Ln O @j Q Q -P O d :p > C5 0� > W Wd io P4� 00 zC NOj �U OL "o Nd LZ :L -� :5O LL -1 I In Lo, ., IL N L F-- L 0 O N 0 (u L NLi- C N > (al L N d-6 O q 0 d N d U 3 75 � U L UJ 4- d 0 O LDL d L L7 +, : L L7 0 Y- d O O a' W OS d L_ Ll L d o L Ln Q ~ LL � O > .-- O S --' W > N S I' W G O Pa W 00 t d 0 lL + (/J Ql 3 6) 0 i a� L (10 0 0U O O 2: U SI-F' O v m @J O_ -H C5 N W S L O Z v lD 4 G" @J L 0 d 0) W Ln Lo, ., IL U 0 (u L NLi- \ d LL- (al Q S- q +' d � >_ 3 75 p U � UJ 4- 0 O LDL 4- W O H r - Ln L co c Ln O Lai W z cd +, O S --' W > O Pa S I' W G O Pa 00 U O)co 00 L @J ID N p L O_ O _ -P C5 -P d -P> N > In ai W W f - Ln S❑ILS LOG - PERC❑LATI❑N TEST CRTHi I M ENGINEERING Performed For: Brent Little Date Perf ormed: 8/30/16 Legal Description: Mountain Valley Estates #1 B5 L11 DEPTH (FEET) T,1-121-ocation: Drawing 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - 14 - 15 - 16 - 17 - 18 - 19 - 20 - SM Silty Sand w/ Gravel Groundwater? No Depth -- Water Depth After Monitoring,none Date; # Date Gross Time Net Time Depth Net Drop 1 8/30 0 -- 6" -- 2 8/30 10 10 min, 0° 6" 3 8/30 12 -- 6" -- 4 8/30 22 10 min. ON 6" 5 8/30 25 -- 6" -- 6 8/30 35 10 min, 0fl 6" 7 8/30 37 -- 6 -- 8 8/30 47 10 min, 0" 6" 9 8/30 50 -- 10 8/30 60 10 min. 0" 6" 21 - ' ' Percolation Rate 1.7 min,/inch Perc Hole Diameter 6" Test Run Between 1' and 2' Comments: PrP -,oak d, M a,-,ar d to nParPst 1 /16th in( -h, Performed By NorthRim Eng, I ..��Z CERTIFY THAT THIS TEST WAS Performed in Accordance with All State/Municipal Guidelines in Effect ❑N THIS DATE, DATE; 8/30/16 NORTHRIM ENGINEERING PO Box 770724 Eagle River, Alaska 99577 907.694.7028 TESTH❑LE LOG GE❑TECHNICAL TA Z� 8/30/16 11 On -Site Water & Wastewater System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151072 Tax Code Number: 05066114000 Work Type: WellSeptic Initial Permit Effective Dates: May 06, 2015 to May 05, 2016 Design Engineer: NORTH RIM ENGINEERING Subdivision: MOUNTAIN VALLEY ESTATES #1 Site Legal Address. MOUNTAIN VALLEY ESTATES #1 BLK 5 LT 11 G:0758 Owner/Address: LITTLE BRENT 3730 BIRDSONG DRIVE EAGLE RIVER AK 995779009 Site Mailing Address: This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy Y Private Well NI Water Storage Lot Size in Sq Ft: 75072 Total Bedrooms: 5 All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing, Special Provisions: PRIOR TO CONSTRUCTION: Additional percolation tests are required prior to construction. If design revisions are required, an approved change order shall be obtained prior to construction. Test resuls shall be submitted with the final inspection report. Received By: Issued By: I I ILA ill L. . MUNICIPALITY OF ANCHORAGE Community Development Department Development Services Division On -Site Water & Wastewater Program Phone: 907-343-7904 Fax: 907-343-7997 USMITTAI ON-SITE SEWERNVELL PERMIT APPLICATION APR 08 2015 Gretchen Stuiler Day phone 62'a r 2 292 Parcel I.D. 0370— 6a/— /4' Property owner(s) E^/r Mailing address 3 7 3 4 groPS..o Q.-r✓e— Site address Smit Legal description (Sub'd., Block & Lot) Vii.ousrei r., (% Legal description (Township, Range & Section) Lot Size 75, 0 7Z Sq. Ft. Number of Bedrooms APPLICATION IS FOR: (El all that apply) Absorption Field r® Septic Tank Holding Tank Privy Private Well Water Storage 0 0 APPLICATION IS AN: Initial Upgrade Renewal p-17.74€.4 4i/ es L// TYPE OF DWELLING: Single Family (SF) (w/wo ADU) Duplex (D) 0 Multiple Dwellings 0 (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property wner or authorized agent) Permit/Rush Fees: Waiver Fees: Date of Payment: 41 Vic Date of Payment: Receipt Number: 60.274/3 Receipt Number: Permit No. OSP/5—/On Waiver No. Permit App_9-1-12.doc THRI M ENGINEERING Date: 4/22/15 To: MOA On -Site Services MEMO Steve Eng, PE, PH (907) 694-7028 tel SteveEngPE@gmail.com Number of Pages: Subject: Mountain Valley Estates #1 Block 5 Lot 11 Comment Sheet, 4/16/15 The sandy soil is good, a shallow trench is designed due to groundwater @ 6'. The owner is planning for a new 5- bedroom house. Slopes are as depicted on the drawing. Higher slopes exist below the road, but there is adequate separation to the septic system. The nearest neighbor's well/septic has adequate separation. Added test holes/perks will be required prior to construction. The owner of Lot 11 also owns Lot 10. Your subject comments have been addressed in the attached revisions. Please issue a permit to install the septic system & drill well. If there is need for additional information or clarification please give me a call. Thanks- Ftw er .: .0 gOI TER I I V I '\ Steven W. Eng c4 ENGINEERING 4g �a „. .�/d7io�ntain Valley Estates #1, Block 5, Lot 11 SPECIFIOATM S/DESIGN GUIDELINES Wastewater System Sizing: This is a new 5-bedroom, single family home. This is at the end of Birdsong Drive and most of the neighbor Its are developed. These lots are large and are served by private water wells. No adverse impacts are expected from development. No conflicts to the other lots will take place by this septic system construction. The easements are located on the drawing and are not encroached upon. Soil tests revealed sandy soil with low silt. The test hole from the subdivision has a fast percolation rate, but soil is about 75% sand. An application rate of 1.2 GPD/FT2 with 0.78 reduction factor for utilizing a 5' wide trench. Trench Length = 625 FT2/5'x .78 reduction factor = 97.5'; 1 line @ 97.5'. No bedrock was encountered. Groundwater was monitored @ 6'. Additional test hole/perks will be required prior to construction. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. • Two compartment, 1500 gallon septic tank. Watertight couplings on inlet & outlet. • 5' minimum between the tank and bed. 10' to property lines. • 3' of cover or insulation is required for trench; an equivalent of 1" insulation for each 1 foot soil cover. • Tank & solid pipe must be set on well compacted, stable soil. • 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. • All cleanouts must extend to at least ground level. • In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. • Trench to be placed level, minimum of 4' to groundwater, 6' to bedrock from drain- rock. • Drain rock to be' /2 inch to 2 %2 inch screened. Drain rock to be distributed uniformly throughout the trench. • Perforated pipe to be installed level with perforations down. • Silt barrier (filter fabric) to be installed above the drain rock. • Smeared trench sides must be raked or scarified before drain rock placement. • Backfill over drain rock must not be less than 36". • The finish grade must be mounded to promote drainage away from trench. • Insulation must be placed over any pipe installed under driveways or parking areas. • Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, • Sewer Service Line is minimum 2% slope. • Septic Tank to be pumped every two years or when required. • Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal) [\bRTFHFIM ENGINEERING MEMO Steve Eng, PE, PH P.O. Box 770724, Eagle River AK 99577 (907) 694-7028 SteveEngPE@gmail.com Date: 4/29/15 Number of Pages: 2 To: MOA On -Site Services 1 Crewdson, PE Subject: Mountain Valley Estates #1, Block 5 Lot 11 New Septic System Design Your Comments, 4/27/15 This is in reply to the subject comment sheet, dated 4/27/15: The owner of lot 11 also is the owner of the adjacent lot 10. These two Lots are very similar and will be developed in the same fashion. The owner makes the following statement concerning your comments: s_a^se: 7he northeast property comers the benchmare at 130'-0". The intent to the have tie `inis- garage slab at 135 -Ct. Tie clesign intent is to develop the lot with aaorox 10%sore drive up to garage slab. jr tent to ter -ace the Lppe, half o` the :ot above the top drive to minimize cut bank on up gradient and ovlde a =re^ch drain near the top of the property_ I intent the too o` the septic mound to be at grade ca ghtly elos; the er •r ve and the mound to slope at 25-33% (code max.) to the lower drive. I do a0t expect any further cut between the septic and the `Ower drive. I am expecting a cat where the property hit. the VCA right of way sim.` ar to what is in place now. t will plaice the lot overburden along the edge of the :-oper:v to :rye n:; reduce t^e slope and carry the level property closer to the actual rdght of way. The drawing has been revised to reflect your comments. The scale and easements modified. Thanks -Steve 0 N -p j 0 E ' ° C L c U-° c c y— ~¢ J E) V U &i .c 5 H Out 0 O 0 C.A Z° c O y z o E 3 0 4N a) v)rr LA N 30' DR GE EASMENT N N N c L £ d N N N x )IJ°d a}o}g U 0 w V/ LJ SYSTEM (5 BDRM) PLAN VIEW SLOPE PROFILE Q W a O d L QJ c O cu U O.1.) 3Q 3 c 0 U -P CS U L 3 0 a, U d i i d N L 3 > O L -J Oi N L 4 d d L N - E E L N E a0 o 20% SLOPE L N a..>_ Da 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 TH'RIM ENGINEERING S❑ILS LOG - PERC❑LATI❑N TEST Date Performed: 10/14/14 Performed For: Brent Little Legal Description: Mountain Valley Estates #1 B5 L11 DEPTH (FEET) Organic SM Silty Sand w/ Gravel T,H, Location: Below Spruce Groundwater? Yes Depth Seeps @ 3' Water Depth After Monitoring,6' Date: 10/22/14 # Date Gross Time Net Time Depth Net Drop 1 10/14 0 -- 10" -- 2 10/14 10 10 min. 0" 10" 3 10/14 12 -- 10" -- 4 10/14 22 10 min. 0" 10" 5 10/14 25 -- 10" -- 6 10/14 35 10 min, 0" 10' 7 10/14 37 -- 10" -- 8 10/14 47 10 min. 0" 10" 9 10/14 50 -- 10" -- 10 10/14 60 10 min. 0" 10" Percolation Rate 1 min./inch Perc Hole Diameter 6" Test Run Between 1' and 2' Comments: Presoaked. Measured to nearest 1/16th inch, Performed By NorthRirn Fng I _ ( CERTIFY THAT THIS TEST WAS Performed in Accordance with All State/Municipal Guidelines in Effect DN THIS DATE. DATE: 10/14/14 `£ I erork NOR THRIM *',49m ENGINEERING PO Box 770724 y„ ogle Riven Alaska 99577 ,/gg 907.694.7028 `j✓� TESTH❑LE LOG GE❑TECHNICAL TH1 but 10/14/14 jnrail