Loading...
HomeMy WebLinkAboutHILLSIDE NORTH #6 BLK 2 LT 3 Rick Mystrom,. Mayor Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 http://www.ci.anchorage.ak.us 343-4744 May 29, 1998 Jeffrey L Barnes Barbara A Symmes 6436 Hampton Drive Anchorage, Alaska 99584 4534 Subject: Lot 3 Block 2 Hillside North Subdivision #6 Permit #SW970086, PID #041-033-02 The subject permit, issued May 9, 1997 by this office for a single family well and/or on-site wastewater system, has expired as of May 9, 1998. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. Ail inspection rePorts must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. Cross, P.E. P~ogram Manager On-site Services enc: Copy of Permit cc: Anderson Engineering PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW970086 DESIGN ENGINEER:ANDERSON ENGINEERING OWNER NAME:JEFFERY BARNES OWNER ADDRESS:6463 HAMPTON DRIVE ANCHORAGE, AK. 99504 DATE ISSUED: 5/09/97 EXPIRATION DATE: 5/09/98 PARCEL ID:04103302 LEGAL DESCRIPTION: HILLSIDE NORTH #6 BLK 2 LT LOT SIZE: 92347 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSA_AC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) . (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: April 21, 1997 Municipality of Anchorage Department of Heath & Human Services 825 "L" Street Anchorage, AK 99502-0650 Subject: Lot 3, Block 2, Hillside North Subdivision, Addn. No. 6 Septic System Design Impacts to Adjacent Properties Dear On Site Services Engineer: We hereby apply for a permit to construct a well and septic system on Lot 3, Block 2, Hillside North Subdivision, Addn. No. 6. The attached site plan and backup documentation identify the location, size and components of the new well and septic system proposed to serve the 3 bedroom house to be constructed on the lot. Testholes placed in the area of the proposed absorption trench revealed a silty gravel with sand with a percolation rate of 8 minutes per inch. No groundwater was noted during the monitoring period nor is any present now. The soil near the alternate site appears to percolate much faster and will require a 2' sand filter as detailed in the attached plan. The surface of the lot slopes from east to west at varying grades, 'but drops off dramatically toward the northwest corner of the prope, rty. The absorption trench will be placed to maintain a minimum of 50' separation from any 25% break in grade. The surface of the ground in the area of the absorption trench is fairly flat. The lot is of sufficient size so that no encroachments will exist between the septic system and any future wells in the area. If the system is constructed as designed the following statements can be made: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. ~;. Lot 3, Block 2, Hillside North Subdivision, Addn. No. 6 April 21, 1997 Page Two The system, if constructed as designed, will have no adverse impact on reserved space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments I ol ITl I I ! II I I .,~, II I I~ THIS PROJECT LOCATION MAP 3, BLOCK 2, HILLSIDE NORTH ADDITi'ON NO. 6 SITE PLAN PROPOSED 3 BEDROOM HOUSE 1,000 GALLON SEPTIC TANK SYSTEM PLAN NO SCALE LOT 3, BLOCK 2, HILLSIDE NORTH SUBDIVISION, ADDN. NO. 6 (ALTERNATE SITE) DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home Perc. Rate: L.T. 1Min./Inch Application Rate: .7 GPD/SF Shallow Bed System 1,000 .Gallon Septic Tank 2' Filter Layer Required 3 Bedrooms X 150 GPD -- 450 Gallons Per Day 450 GPD/.7 GPDISF -- 643 SF ! 15 LF (Width)= 43 LF Total Length Therefore: Construct a Shallow Bed System' With a Total Length of 43' and 15' Wide. Distribution Piping to Be Placed 3.5' Below Existing Ground Surface. ~ TYPICAL ELEVATED MOUND SECTION (NO SCALE) Maintain 50' Separation From 25% Slope. Grade Area Over Bed to Drain Away. LOT 3, BLOCK 2, HILLSIDE NORTH SUBDIVISION, ADDN. NO. 6 DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home Perc. Rate: 8 Min./Inch Application Rate: .8 GPD/SF Wide Trench System 1,000 Gallon Septic Tank 4' Drainfield Rock 3 Bedrooms X 150 GPD / .8 GPD/SF = 562.5 SF of Absorption Area 562.5 SFI5 LF X .5 (Red. Factor) -- 57 LF Length of Trench Therefore: Construct a Wide Absorption Trench With One Lateral 57' in Length. Distribution Pipe in Trench Placed at 3.0' Below the Original Ground Surface. /// TYPICAL WIDE TRENCH SECTION (NO SCALE) Grade Area Over Trench to Drain Away. Maintain 50' Separation From 25% Slope. Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST .ERFORMED FOR: ~.~sc~,.,o.:~r~, .~. ~.~ 1 2 4 DATE PERFORMI Township, Range, Section: SLOPE SITE PLAN A 10 11 12 13 14- 15- 16- 17- 18- 19- 20- WAS GROUND WATER ENCOUNTERED? S L IF YES, AT WHAT O DEPTH? P E 0,,...or~r 7/7/% Monitoring? ,~/~ Date: Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE ~ (m~nutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN/'~ I/~,. FT AND ~' yZ.. FT ,~, /-/,~ ~ , ~ ~.~v THAT ~.,~TEST WAS PERFORMEO'N PERFORMED BY: ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: '~/1 MmticJpM~ o! Afl~hM~j~ DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" ~t(,~t, Anchorage, Al~kl 99,'~t-00ffi SOILS LOG -- PERCOLATION TEST 1 3 4 6- 6- 8 9- 11 13- 14 16 17 18 19 COMMI~NT$., , DATE PERF~ CERTIFY THAT THIS TE~T WAS PERFORMED IN PERFORMED BY: ACCORDANCE WIT H ALL STATE AND MUNtCAPAL OUIOELINg$ IN ?Z4~(~ tReY 4/63) WAS GROUND WATER ENCOUNTIRED? HO J IF 'YES. AT WHAT DEPTH? SLOPE SITE PLAN .t Rladir. g i~ Time Time W~ Town~hlp. Range. Section: