May 29, 1998
Jeffrey L Barnes
Barbara A Symmes
6436 Hampton Drive
Anchorage, Alaska
99584 4534
Subject: Lot 3 Block 2 Hillside North Subdivision #6
Permit #SW970086, PID #041-033-02
The subject permit, issued May 9, 1997 by this office for a
single family well and/or on-site wastewater system, has
expired as of May 9, 1998.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as-built inspection report must be sent to this office for
review, approval and documentation. Ail inspection rePorts
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastewater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
Cross, P.E.
P~ogram Manager
On-site Services
enc: Copy of Permit
cc: Anderson Engineering
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW970086
DESIGN ENGINEER:ANDERSON ENGINEERING
OWNER NAME:JEFFERY BARNES
OWNER ADDRESS:6463 HAMPTON DRIVE
ANCHORAGE, AK. 99504
DATE ISSUED: 5/09/97
EXPIRATION DATE: 5/09/98
PARCEL ID:04103302
LEGAL DESCRIPTION:
HILLSIDE NORTH #6 BLK 2 LT
LOT SIZE: 92347 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSA_AC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) . (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
April 21, 1997
Municipality of Anchorage
Department of Heath & Human Services
825 "L" Street
Anchorage, AK 99502-0650
Subject:
Lot 3, Block 2, Hillside North Subdivision, Addn. No. 6
Septic System Design
Impacts to Adjacent Properties
Dear On Site Services Engineer:
We hereby apply for a permit to construct a well and septic system on Lot
3, Block 2, Hillside North Subdivision, Addn. No. 6. The attached site plan
and backup documentation identify the location, size and components of
the new well and septic system proposed to serve the 3 bedroom house to
be constructed on the lot. Testholes placed in the area of the proposed
absorption trench revealed a silty gravel with sand with a percolation
rate of 8 minutes per inch. No groundwater was noted during the
monitoring period nor is any present now. The soil near the alternate site
appears to percolate much faster and will require a 2' sand filter as
detailed in the attached plan.
The surface of the lot slopes from east to west at varying grades, 'but
drops off dramatically toward the northwest corner of the prope, rty. The
absorption trench will be placed to maintain a minimum of 50' separation
from any 25% break in grade. The surface of the ground in the area of the
absorption trench is fairly flat. The lot is of sufficient size so that no
encroachments will exist between the septic system and any future wells
in the area.
If the system is constructed as designed the following statements can be
made:
The system, if constructed as designed, will have no adverse impact
on the wells in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact
on existing septic systems in the area or those to be constructed in
the future.
~;.
Lot 3, Block 2, Hillside North Subdivision, Addn. No. 6
April 21, 1997
Page Two
The system, if constructed as designed, will have no adverse
impact on reserved space, either surface or subsurface, on any lots
located in the area.
The system, if constructed as designed, will have no adverse impact
on drainage patterns in the area. The current drainage pattern will
be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
I
ol
ITl
I
I
!
II
I I .,~,
II
I I~
THIS PROJECT
LOCATION MAP
3, BLOCK 2, HILLSIDE NORTH
ADDITi'ON NO. 6
SITE PLAN
PROPOSED 3 BEDROOM
HOUSE
1,000 GALLON
SEPTIC TANK
SYSTEM PLAN
NO SCALE
LOT 3, BLOCK 2, HILLSIDE NORTH
SUBDIVISION, ADDN. NO. 6
(ALTERNATE SITE)
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
Three Bedroom Home
Perc. Rate: L.T. 1Min./Inch
Application Rate: .7 GPD/SF
Shallow Bed System
1,000 .Gallon Septic Tank
2' Filter Layer Required
3 Bedrooms X 150 GPD -- 450 Gallons Per Day
450 GPD/.7 GPDISF -- 643 SF ! 15 LF (Width)= 43 LF Total Length
Therefore: Construct a Shallow Bed System' With a Total Length of 43'
and 15' Wide. Distribution Piping to Be Placed 3.5' Below Existing
Ground Surface. ~
TYPICAL ELEVATED MOUND SECTION
(NO SCALE)
Maintain 50' Separation From 25% Slope.
Grade Area Over Bed to Drain Away.
LOT 3, BLOCK 2, HILLSIDE NORTH
SUBDIVISION, ADDN. NO. 6
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
Three Bedroom Home
Perc. Rate: 8 Min./Inch
Application Rate: .8 GPD/SF
Wide Trench System
1,000 Gallon Septic Tank
4' Drainfield Rock
3 Bedrooms X 150 GPD / .8 GPD/SF = 562.5 SF of Absorption Area
562.5 SFI5 LF X .5 (Red. Factor) -- 57 LF Length of Trench
Therefore: Construct a Wide Absorption Trench With One Lateral 57' in
Length. Distribution Pipe in Trench Placed at 3.0' Below the Original
Ground Surface.
///
TYPICAL WIDE TRENCH SECTION
(NO SCALE)
Grade Area Over Trench to Drain Away.
Maintain 50' Separation From 25% Slope.
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
.ERFORMED FOR:
~.~sc~,.,o.:~r~, .~. ~.~
1
2
4
DATE PERFORMI
Township, Range, Section:
SLOPE
SITE PLAN
A
10
11
12
13
14-
15-
16-
17-
18-
19-
20-
WAS GROUND WATER
ENCOUNTERED?
S
L
IF YES, AT WHAT O
DEPTH? P
E
0,,...or~r 7/7/%
Monitoring? ,~/~ Date:
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE ~ (m~nutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN/'~ I/~,. FT AND ~' yZ.. FT
,~, /-/,~ ~ , ~ ~.~v THAT ~.,~TEST WAS PERFORMEO'N
PERFORMED BY:
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: '~/1
MmticJpM~ o! Afl~hM~j~
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" ~t(,~t, Anchorage, Al~kl 99,'~t-00ffi
SOILS LOG -- PERCOLATION TEST
1
3
4
6-
6-
8
9-
11
13-
14
16
17
18
19
COMMI~NT$., ,
DATE PERF~
CERTIFY THAT THIS TE~T WAS PERFORMED IN
PERFORMED BY:
ACCORDANCE WIT H ALL STATE AND MUNtCAPAL OUIOELINg$ IN
?Z4~(~ tReY 4/63)
WAS GROUND WATER
ENCOUNTIRED? HO
J
IF 'YES. AT WHAT
DEPTH?
SLOPE
SITE PLAN
.t
Rladir. g i~ Time Time W~
Town~hlp. Range. Section: