HomeMy WebLinkAboutHILLSIDE PARK PUD LT 22D Municipality of Anchorage JMIN d tU41 On -Site Water and Wastewater Section • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP211280 PID Number: 015-312-16 Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ® Upgrade Name JULIANA & HARLAN WOLD ABSORPTION FIELD - EXISTING ❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 7080 EAST TREE COURT, ANCHORAGE ❑ Other Phone Number o f Bedrooms Soil Rating Total depth from original grade 4 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot HILLSIDE PARK PUD 22 Fill added above original grade Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines SEPARATION DISTANCES Ft. To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line FtZ Ft. Well 200'+ -- 25'+ T�.�■. ® Septic ❑ S.T.F.P. ❑ Holding ❑ Other Manufacturer Capacity Surface Water 100'+ -- GREER 1250 Gal. Material Number of compartments Lot Line 51+ __ NA HDPE 2 Foundation 7'+ __ LIFT STATION Manufacturer Capacity Remarks TANK INSTALLED IN SAME LOCATION AS Gal. PREVIOUS TANK & PER PERMITTED DESIGN. Alarm location Electrical installed by Installer A+ PIPE MATERIAL House to tank 3034 Tank to 3034 drainfield Drainfield CO/MT 3034 Inspector FWCS BENCH MARK (Assumed elevation) 100 ft Inspdecctiiosn 1:t 9/13/21 2nd 9/13/21 Location and description 3'd 10/22/21 4'h BOTTOM OF SIDING NEAR SWING TIE "A" ON-SITE WATER AND WASTEWATER SECTION APPROVAL 4� • • "' Conditional Approval: Date AIdow W • • • • • • • • • •V• Septic System A pp rov - % Curtis Huffman Date /4 �F���••• CE 128991 ��'/� 2 •.. lF� . 12/20/20;] F\\ .AW PROFESSION.� Note: this approval does not include well permit requirements. m.... nunnm n -'/ PID: 015-312-16 PERMIT. OSP211280 200' WEL\ LOT 23 �Z j / RAD LOCATED WATERLINE \ / PRIOR -TO CONST. / KEY BOX / 10'+ TO ST D C 6 A `�gZ / DC0540 db DECOMMISSIONED EXISTING S.T. & INSTALLED NEW LOCATION OF FIELD 1250 -GAL HDPE MT IS UNKNOWN SEPTIC TANK. l LOT 22 7 i PAVED D/W / FCO H DCO A—C=9.9' C0 98.28 MNAL GRADE B—C=33.6' if A A—D=14.1' 94.21 B—D=34,3' A—E=16.3' 93.63 1,25D -GALLON 3.48 HDPE TANK 5'+ TO MUD EXISTING MEW B — E = 3 5.0' VERIRED OUTSIDE SOIL BEARING PRISM PER PERMIT. i+ TO FMOVED EXISTINGFOUNDST & INSTALLED IN SEPTIC SECTION SAME LOCATION. SCALE, NTS HILLSIDE PARK PUD LOT 22 PREPARED FOR: HARLAN & JULIANA WOLD 7080 EAST TREE COURT ANCHORAGE, AK 99507 FIRST WATER CONSULTING 13030 SUES WAY ANCHORAGE, AK 99516 907-350-9566 firstwaterAK©gmail.com MT LOC. UNKNOWN SUPPORTS SERVICES: OF .AL C 9 TH DATE: 12/20/21 tis Huffman SURVEY: JLS CE 128991 w DRAWN: FWCS 12/20/21 v$ SCALE: 1" = 20' 1 N E53I���' X X X 15'022 3„9£,99.68N pe, IZ \ �J lift ll 6 `� v cD v> .'I Wo a a. 3 U O 7"5 w o NZ �9 LLC Q Y N 0 w cc 0 02 Aa C', CQ ONCQ O s. Ln p co 40 N O O ?712Ha5 O• o f t� � t 'Jt5 O'fa,��® xa0 Q��,J:arn o2ho a 4z a it � b ZJ �C` x L61 / A O O 5 N !.� °) ��. b O W W N 0 �o�, a2cq U to O O R~ gg N � b A O O 5 N !.� °) ��. b O W W �o�, a2cq U to O O R~ gg N On � C4 C -1 ,ob -3 Q G O .� p <¢ A CG Q� ►� a A U � � v, « 8 u W °� ai W o o o Mej O m 00 c p U aH > N o �• o I z Cl2 —0 }, A v? u U S A a d d�"aa.ai9 WYb `�' MUNICIPALITY OF ANCHORAGE On -Site Water & Wastawater Program PO Sax 11M850 4704 Elmore Pond Anaharege, AU k8 7P-5550 PMne! (90n $43.7964 rex' (91)71 04 7.99} h[1p;flWWW.MVni, moi* On -Site Wastewater Disposal yst-em Permit Perm f# Nurnlber: O-SP2112N Work Type: SepticTank Upgrad e Tax Cade Number: 01581216000 Site Legal Address- H IL LS I DE PARK PUD LT 22 Cp-2539 Site Mai Ling Address, 7080 EAST TREE CT, Anchorage Ownor_ WOLD HARLAN a & JULIANA Design Engineer- FIRST WATER CONSULTING This permit is for the construction of. 0 Disposal Field Q S-eptic Tank ❑ Holding Taek (*I Privy Effective Date= Expiration Date; Lot Size In Sq Ft Total Bedrooms: f. ] 4�I�;ir[nitini 7127;2022 X242 El Private Weil ❑ Water Storage Ail constructiGn shall be in accordance with: 1, The aaached approved 4osign, 2. All requirements sp-ocifed in Anchorage Municipal coda Chapters 1:5-5:5 and 15-65 and the Stam of Alaska 'l as(awater Dispos-aI Rog ulations (18AAC72) and Drinking Yater Regulations C1 4C80j 3. The wastewater code requires inspections during the installation- The engineer shall notify the Development Services Department per AMC 15.85- Provide notification bar calling (907) 343-7904 (207), 4. From C�ctcber 16 to Apri1 15, a subsurface soil absotlatim systern under const%u Ion durIng froozing weather shall be either= a. Op"ed and Closed on the same day, cr b. Cereo, sealed, and heated tD prevent freezing Special Provisions: 1, The water service line is to be IOcaMd prieF to tank install- If the lime is less than 19' front the proposed tank location, ccnsWuction of the system will stop pending Onsite review and 8ppro ZLI. 2. LDcata the beginning of the field to confirm that tine 5' separation between the WO and Fuld will be met, Reuuiv ud By. teuveo My: wr— 7!2712021 date: f 1P.11y. I 4 MUNICIPALITY F ANCHORAGE .:f Development Services Department �` Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I. D. 015-312-16 Property owner(s) HARLAN & JULIANA WOLD Day phone _ Mailing address 7080 EAST TREE COURT, ANCHORAGE, AK 99507 Site address 7080 EAST TREE COURT, ANCHORAGE, AK 99507 Legal description (Sub'd., Block & Lot) HILLSIDE PARK PUD LOT 22 Legal description (Township, Range & Section) Lot Size 34,242 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) El (w/wo ADU) Septic Tank 0 Upgrade (D) El Holding Tank ❑ Renewal ElDuplex Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 1-125 Waiver Fees: Date of Payment: 7 //-z /21 Date of Payment: Receipt Number: 3 / 2 /3 Ll Receipt Number: Permit No. 0_522_ 112 so Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / firstwaterAK@gmail.com July 12, 2021 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: SEPTIC TANK UPGRADE PERMIT LEGAL: HILLSIDE PARK PUD LOT 22 The owner has requested that we obtain a septic permit to upgrade the existing aged steel septic tank on the above referenced lot. We propose to install a 1250-gallon HDPE tank per the attached design to serve the existing 4-bedroom residence. The lot and area are served by a Class A water system. The design will not impact any of the neighboring properties. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211280, Deb Wockenfuss, 07/27/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211280, Deb Wockenfuss, 07/27/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211280, Deb Wockenfuss, 07/27/21  MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME IPHONE E~NEW MAILING ADDRESS 7 ~oo -C. LEGAL DESCRIPTION L 2,2 14,'~\~;~_ ~oc~,o~ ~o. o~ ~oo~ Well Absorption area Dwelling PERMIT NO~ ~ ~ Manufacturer ~~ Material No. of compartments r ~i~,~n~7~ ~Z~ ~ No, of lines ~ Length~ each line Total length~of lines Trench~ ~width ~ ~ = ~ ~ Top of tile to finish~d~ ~aterial beneath tUe ~Z Total efk~t~v~absomtion ken,th ~idth Deoth P~T ~0. ~ Ty Crib d effe on ~ Build~u ndation Near~t line ~ ,,OlSTANC E TO: ~ ~ Class ~ Depth Driller Distance to lot line PERMIT NO, ~ DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER ~ )~,~..~. ;~ ~ ~ PIPE MATERIALS /~;~ ~k / REMARKS / x o < N /I / - APPROVED DATE LEGAL PERMIT NO. ( 8103~4B > DEPFIRTMENT & HS~LTH ~ND ENVIRONMENTAL ~ .OTHCTtON 825 "L" STREET, RNCHORRGE, RK. S¢~501 RPPLICRNT 1.4INTER WISE INCE 7400 E. 20TH LOCRTION EFIST TREE L. EGRL L22 HILLSIDE PRRK LoT SIZE 2(4242 S6!URRE FEEl" TYF'E OF' SOIL RBSCF.'F'TION :,~:,TEM Is,. TRENL. H MRXIMUM NUMBER OF BE[:,R]")MS = 4 =,UIL RFITING ,.'.51..! FT..BR..- THE RE~t..IIF.:ED =,I~E OF THE SOIl_ HB_,LIF. FTI_N :,,_,TEM IS: [:, E F" T l-t = :t. ~Zi L E ~'-.~ ,3 T H = =~'._, .:.'-" ,3 F-I R '..-" r:: L [:, E: F' T HI ..-== (5 THE LENGTH [:,IMENSION IS THE LENGTH (IN FEET) OF THE TRENCH LR DRRINFIELD. THE DEPTH OF R TRENCN OR F'IT I'=_, THE DISTFINCE BETWEEN 'THE SURFRC:E OF THE ~" "- ~,~ F1 . CiROLIND FIND THE BOTTOM OF THE E,.~,CH,,RTI_N (IN FEET:). THERE IS NO SET WIDTH FOR TF, ENCHE_,. THE 6RFIVEL DEPTH IS THE MINIMUM DEPTH OF GRR',/EL BETt.,.IEEN THE OLITFRLL PIPE FIND THE BOTTOM OF THE E:qCR'¢RTION (IN FEET.'.,. - ' "' I N . .. PEF.:MIT HPFLIL. HNT HR.. THE RE=,F_N_IE, ILIT-r TO FORM ]"HIS DEF'RRTMENT DURING THE INSTFILLRTION INSPECTIONS OF FIN'¢ WELLS RDJRC:ENT TO THIS FF..OFERT'r FIN[:' THE NUMBER I]F RE.s, IDENCE_, THFIT THE WELL WILL =,EF.,E. MINIMUM DISTRNCE BETWEEN R NELL RND RNV ON-SITE SEWRGE DISPOSRL S'¢STEM IS iOR FEET FOR FI PRIVRTE NELL. OR ~50 TO 200 FEET FROM FI PUBLIC NELL DEPENDING UPON THE T'¢PE OF PUBLIC WELL MINIMUM [:,ISTFINCE FROM R PRIVFtTE NELL. TO FI PRIVRTE SEWER LINE IS 25 FEET FIND TO FI COMMI..INIT'¢ SEWER LINE IS 75 FEET. OTHER REC.!UIREMENTS MRS' RPF'L~'. SPECIFICRTIONS RND CONSTRUCTION [:i!RGRRMS FIRE FIVFIILFIBLE TO INSURE PROPER INSTFILLRTION. ..... RE__, [. EL. EF18EF. F'ERF'! I: T E,--,F I ':" I CERTIFY THRT i: I RM FRMILIRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND NELL. S RS SET FORTH BY THE MUN:[CIPFIL. ITV OF RNCHORFIGE. 2: I NILL INSTRLL. THE SYSTEM IN RCCORDFINCE WITH THE CODES. 3: I UNDERSTRND THFIT THE ON-SITE SEWER SYSTEM MFIY REQUIRE ENLRRGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THRN 4 BEDROOMS. S I GNED: V4. 0 PERFORMED FOR: LEGAL DESCRIPTION: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG- PERCOLATION TEST DATE PERFORMED: SOILS LOG PERCOLATION TEST 1¸- 2 3 4 5 6 7 8 9 10 11 12 13- 14- 15- 16 17 18 19 20 COMMENTS SLOPE I 1/11 I 1/111 Ill III III III SITE PLAN WASGROUND WATER S ENCOUNTERED? ~O ~ P E IF YES, AT WHAT DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE__ TEST RUN BETWEEN' CERTIFIED 'E: ~JX," Time Time , .,e Date Date Date Inspector Inspector Inspector Comments Conditional Approval ' ' ' , :: ',~al Approval Date Sewer Installed Permit No. Septic Tank Size ~-- ~ ~ 1 Holding Tank Size Soils Rating Well To Absorption Area Well Log Received Well to Tank APPLICANT FILLS OUT LOWER HALF ONLY PropertyOwner ~v ~;~o.~ ~. ~ ~r~ D~,'~ Phone Mailing Address ~00 ~, ~0~ ~U~ Buyer ~V, ~ ~. ~aVl~ ~, Lendinglnstitution ~K- pacr6rc ¢~.k ~; ~,¢ ~e~b~* Phone Address ~ ~ OI " ~' Legal Description ~+, ~Zi ~t #5;~ ~ Street Location ~5~' ~P~ Typ~f Residence ~ 8inoIo ~amily ~ Multiplo Family ~o. of Bodrooms ~ Othor Wator Supply ~ Individual ff~tJ~ ;J' P~ ~ ~ AWACH WELL LOG. A well log is required for all wells drilled since June Community 1975. For wells drilled prior to that date, give well depth (attach log if Q Public Utilit~ available.) Sew~e Disposal ~ Individual Year Individual Installed: ~ Public Utility When Connected to Public Utility: ~ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. MUNICIPALITY OF ANCHORAGE z- 01,31 Development Services Department ; Phone: 907-343-7904 On -Site Water & Wastewater Section \' -' Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I. D. 015-312-16 Legal description HILLSIDE PARK PUD LT 22 Site address 7080 EAST TREE CT Anchorage AK Current property owner(s) RENNICK Expiration Date: 6/19/2025 X The On -site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: By: Original Certificate Date: 6/27/2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval —June 2022 Development Services Department On -Site Water & Wastewater Section MUNICIPALITY OF ANCHORAGE RU5 1i R Phone: 907-343-7904 Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 015-312-16 Complete legal description HILLSIDE PARK PUD LOT 22 Location (site address) 7080 EAST TREE COURT, ANCHORAGE, AK 99507 Current property owner(s) CHERYL L RENNICK Day phone 2. ON -SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: ❑ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units Z Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: 0 Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel Z Plastic ❑ Concrete ❑ Fiberglass Age 3 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed Z Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: 0 Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee$ 550 Date of Payment C 0 S A # 0' C 2- 9 12 Waiver Fee $ Date of Payment Waiver # COSA Application.doc COSA Checklist.docx COSA Checklist Legal Description: HILLSIDE PARK PUD LOT 22 Parcel ID: 015-312-16 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA - PUBLIC &/OR CLASS “A” WATER Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume NA gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank 58” Date of pumping 6/19/2024 Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 6/22/1981 ALL standpipes present per record drawing Total measured depth from grade 10.5 ft (max) Measured depth to pipe invert from grade 5.4 ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes (MT) go to bottom of effective (ED). If not, state depth into effective 5.3’ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) N If yes, enter date Adequacy test date 6/21/2024 Results Pass Fluid depth prior to test 0 in Water added 1000 gal New fluid depth 0 in Elapsed time <1 min Final fluid depth 0 in Absorption rate 600 gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) 72 in (MOA 6’ ED) Effective depth used 8 in (Missing ED + Final Fluid Depth) Effective depth remaining 64 in Comments/Deficiencies: Approximate total measured depths from existing grade. ED per elevation measured shots of new double cleanout & driven MT in field & appears approximately 8” of ED is missing. The end of the field was not disturbed due to not wanting to impact more and the end of the field is approximately 12’ from the field cleanouts installed. Per record docs, insulation in driveway and partly at field start. COSA Checklist.docx E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) - NA Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Engineer’s Printed Name CURTIS HUFFMAN, PE Date 6/24/2024 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & 6/24/24 EXCAVATED & INSTALLED DCO & MT. SKETCH PERTHIS EXCAVATION, RECORD DOCUMENTS & VISUALOBSERVATIONS - FIRST WATER CONSULTING. SCALE 1:30