HomeMy WebLinkAboutKNIK HEIGHTS BLK A LT 10LoT 0/70: Z MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME r~t MAILING ADDRESS FO LEGAL DESCRIPTION LOCATION Well DISTANCE TO: Liq. IF HOMEMADE: DISTANCE TO: Absorption area /7 Inside length Dwelling mufacturer DISTANCE TO: 3 of tile t nish Length Type of crib Len'nth- of each'Ii'ne fade Width Crib diameter Well Foundation 7 ' i Totl~of I~as Material be~ff~ath tile Depth Crib depth Building foundation PHONE ~EW DwellingT~ / Mat eri~._~ IWidth Material Nearest lot lin)~ ~,¢. Trench w~dt~ inches inches NO. OF BEDROOMS No. ~)f ~o~aen, ts Liquid depth PERMIT NO. Liquid capacity in gallons Distan~een lines Total effective abs~l;~tion area PERMIT NO. Total effective absorption area Nearest lot line DISTANCE TO: Class Depth Driller Distance to lot line PERMIT NO. Building foundation Sewer line Septic tank Absorption area(s) DISTANCE TO: OTHER PIPE MATEEtlALS SOl L TE;T,¢~T,~/~ INSTALLER REMARK8 LEGAL (Rev. 3/78) DATE DEPARTMENT OF HEALTH AND ~.' IRL~ ' ' 825 "L'" STF.'.EET.. ANCHORFIGE., ' 264-4728 TYPE CF ~3IL RBS'IRETICN ~YSTEM IC;' DRRINFIELD THE REGILIIRED SIZE OF THE SOIl_ RBSORPTION SYSTEM TIlE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF B TRENCH OR PIT IS THE DIS'TFINCE BETWEEN THE SURFFtCE OF THE GROUND FIND THE BOTTOM OF THE EXCFIVATION (IN FEET). THE GRFIVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFRLL. PIPE RN[.', 'THE BOTTOM OF' THE EXCRVFITION (IN FEET). PERMIT RPPLZCFINT HFIS THE RESPONSIBILIT9 TO INFORM THIS DEPFIRTMENT DURING THE INSTRLL.FITION INSPECTIONS OF FINV WELLS FIDJRCENT TO THIS PROPERT9 FIND THE NUMBER OF RESIDENCES THRT THE WELL WILL SERVE. BFtCKFILLING OF FtNY SYSTEM WITHOUT FINRL INSPECTION RN[:, RPPROYAL BY THZ:5 [:,EPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTFINCE BETWEEN R WELL FIND FINY ON-SITE SEWRGE [.',ISPOSRL. SYSTEM IS · 00 FEE]' FOR FI PRIVFITE WELL; OR ~.50 TO 200 FEET FROM FI PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC I.,.!EL.[ .... WEL. L LOGS RRE REQUIRED RND MUST BE RETURNED TO THE DEPRRTMENT WITHIN ]:0 DRYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MFIY RPPL. Y. SPECIFICRTIONS FIND CONSTRUCTION DIFIGRFIMS RRE. I C:ERTIF'r THAT ~ ¢ ~ L~ l' I RM FRMILIRR WITH THE RE~;~IIIREMENT=, FOR ON-'z, ITE SEWERS 8NJ:, WELL=, R% SET ~ FORTH BY THE MUNICIPRLZ]"Y OF RNCHORRGE. 2: I WILL INSTRLL THE SYSTEM IN RCCORDRNCE WITH THE CODES. 2:: I UNDER%TRND THR'r THE ON-SITE %EWER SYSTEM MRY REQUIRE ENLRRGEMENT IF THE RESI[:,ENCE IS REMODELED TO INCLUDE MORE THRN 2: BEDROOMS. AF'F'LICFINT RI~ZtF~, S. GZESSEL ' / ~SSU[D BY_ ~ ' ~'~'. August 6, 1979 Richard S. Giessel P.O. Box 10-785 Anchorage, Alaska 99511 Subject: Soil Investigation for Sanitary SeWer System, Lot 10, Block A, Knik Heights Subdivision, Anchorage, Alaska Dear Mr. Giessel : At your request of August 6, 1979, we conducted a subsurface soils investi- gation at the proposed location of the sanitary sewer system on the subject lot. The investigation complied with those procedures required by the Municipality of Anchorage Department of Health and Environmental Protection. This investigation, which was accomplished on August 6, 1979, consisted of a test pit excavated to a depth of 16 feet below the existing ground surface. The test hole was sited according to your instructions and its location is shown in attached Drawing A-01. Excavation was accomplished with a backhoe. Samples were taken at the depths shown on the soils log in Drawing A-01. The samples will be held in storage at our lab for approximately six months. In addition, all material excavated was continuously monitored by an experienced geotechnical engineer. The topography at the excavation site is generally gently-sloping to the west-southwest. At the time of the investigation the site had original vegetation consisting of large birch and spruce trees. The top of the test pit was located at original ground surface. The soils encountered in the excavation are shown in the test hole log in Drawing A-01. This log displays specific conditions encountered at the test location. However, subsurface conditions may vary in other parts of the lot without any apparent surficial evidence of the change. Groundwater was not encountered and bedrock was not encountered. At the time the hole was excavated seasonal frost was not present and permafrost was not encountered. Two percolation tests were performed~es in pits adjoining Test Pit #1 at a depth of~threeone half fee~.X_xThus, the percolation occurred in sandy gravel ~trata located tree one half to five feet below the surface. Both holes were filled with three gallons of Page -2- water. The measured percolation rates were 10.9 and 13.3 minutes per inch fov test one and two respectively. We appreciated this opportunity to be of service to you. Please contact us if you have any questions concerning this letter or if we can be of addi- tional service. Very truly yours, R&M CONSULTANTS, INC. Ernest R. Rahaim Staff Geologist ERR:GS/rm/ATSI-K /'7° MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Pouch 6-6E0, Anchorage, Alaska 99B02 276-222"~ SOILS LOG-- PERCOLATION TEST ~. SOILS LOG [] PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: LoT 1 5 6 7 8 9 10- 11 12 13- 14- 15 16 17 18 19 20 O¢-G/~i~ll¢ NIt~'I (0 - 0,4 F~T;J] SLOPE $1bT¥ ~N~ WITN I ~ - - WAS GROUND WATER ~ ~ '~ I ~ ENCOUNTERED? IF YES, AT WHAT DEPTH? ~,W,T, SITE PLAN } ;I'-~-c~/-],',~~ Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE (minutes/inch) COMMENTS TEST RUN BETWEEN FT AND -- FT PERFORMED BY: ~lCN/~,~,l) ~;. GIE~SF? CERTIFIED BY: DATE: 72-008 (7/76) PERCOLATION TEST ~-~, ',~¢7¢ R&M No. ~1E55£l. TIME $~00 9;05 ELAPSED TIME (MINUTES) 5 WATER LEVEL (INCHES) INCREMENTAL (INCHES) DROP 4.0 Io.~1 PERCOLATION TEST ~¢- (..- 1¢ 7o)' R&M No, C~l/::_~5,~,F-. L- # ?):40 lO;lo TIME ELAPSED TIME (MINUTES) WATER LEVEL (INCHES) I! 7 ,¢ INCREMENTAL DROP (INCHES) 1 I~ ' W DRILLING, /nc. P. O. Box 4-1224 o 1310C International . '~Y MUNICi?AL!Ty OF /~NCF~ORAG ANCHo~ 274.4611 A~rport DEPT. C - Road EF~/IROF, /',Ex ~,_ ~, AL~s~ 99509 - ~- , ~CTiOA, Well Owner~ DRILLING LOG ~ddress o~: TOWns V S[atic water ]eve~L eet v~. -:: Cased to~8~eet Screen ( ); Perforated ( ). . . ~e)_ (below) land surface. F~ish of well (cheek one) Describe screen °r'perforatio open end We/I Pumping test of drawdown ~er ~) (minute) from static level, for~ Date of eomp]e/io 3' 2& 79 ~ ~ours ground surface ~ations ~TO_ 86 125 . ~62 Z75 182 ~TO ~TO~ ~TO~ Cereifi'e;d, xr , ~'- '-' ' ! DATE,'.'~'~CEIVED < INSPECTION APPOINTMENTS ,TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR MUNICIPALffY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE DEPT. OF H-~ALTH & t DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTI~NVIRONMENTAL PROTECTION  925 L Street - Anchorage, Alaska 99501 DEC I[ .; 979 ENVIRONMENTAL SANITATION DIVISION Telephone 264-4720 RECEIVED REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed, Please allow ten (10) days for processing. 1. PROPERTY OWNER PHONE MAI~,-I NG ADD R ESS ' ~.7¢,~.~z'9 PROPERTY ~ES DENT (If differe PHONE 2. BUYER PHONE MAILING ADDRESS 3. LENDING INSTITUTION PHONE MAILING ADDR[~S'S~ ' ' 4. REALTOR/AGENT r ] PHONE I MAILING ADDRESS 5. LEGAL DESCRIPTION LoT STREET LOCATION 6. TYPE OF RESIDENCE ~, SINGLE FAMILY [] MULTIPLE FAMILY ')O¢'El'/ RVPFM N NUMBER OF~BEDROOMS ~ One ~ Four ~ Two ~ Five ~ Three ~ Six Other 7. WATER SUPPLY INDIVIDUAL~ [] COMMUNITY [] PUBLIC UTILITY *ATTACH WELL LOG. Awelt log is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM ,ND,V,OUAL/ON-S'TE** /¢7;1 [] PUBLIC UTILITY YEAR ON-SITE SYSTEM WAS INSTALLED, NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. THIS SIDE FOR OFFICIAL USE ONL'~ 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [~ ONE [~ THREE [-q FIVE E~ OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER E~] INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER []Septic Tank or []Holding Tank Size: iL ~,'~'~ If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL Septic/Holding Tank Absorption Area ISewel0Line [ Nearest Lot Line 4. DISTANCES WELL TO: Absorption Area to nearest Lot Line 5, COMMENTS [~-- APPROV ED FOR ~ BEDROOMS [] CONDITIONAL APPROVAL {letter must accompany certificate) E~] DISAPPROVED DATE BY 72-010 (Rev, 6/79) December 14, 1979 Richard Giessel Post Office Bo× t0-7~5 ~%chmrage, Alaska 99511 Subject~ Lot 10 Block A Knik Heights S~mbdivision Approval for your individual s~wer and wa%er facilities can not be granted until the follo%~ing items have been completed: (1) .The water analysis report be delivered to this office from ~hem Lab~ 5633 B Stree'h, for o%~ review. 0.'(3) Your sewer line has apparently broken and sewage is surfacing on the groun~o This must be .repaired before approval may be grante~o'--~,~-~ ~ C~ .... If there are any further questions, please contact this of~l~,e at 264.-4720° Sincerely Robert C, Pratt~ RcS. Associate Specialist cc ~ Alaska Pacific Bank ~rtgage Loan Department ~01 East Benson 99503 December 20, 1979 Mr. Robert C. Pratt, R.S. Municipality of Anchorage Dept. of Health and Environ. Protection 825 L St. Anchorage, Alaska 99501 Dear Mr. Pratt: I received your letter of December 14. Enclosed find the drinking water analysis report. In response to your statement that my sewer line was broken, please note that the municipality approved a dual drain system for my house. My sewer line is intact. The water, not sewage, which is surfacing near the end of the driveway comes from the second drain system. This second system carries water from garage and basement floor drains as well as perforated pipe buried around the base of my foundations. I hope this answers your questions. Yours truly, Richard S. Giessel P.O. Box 10-785 Anchorage, Alaska 99511 Lot 10 Block A Knik Heights Subd. cc: Alaska Pacific Bank TO BE COMPLETED ~Y~WATER SUPPMER: :" '~ · /J-- '-':.'?~'.."1.0. NO. _ · 8t~le ' Z~p Code MO. Day ::~.- Ye~ U Routine ' ,': ~ Check Sample (for routine sample ) with tab ref. no ~ Treated Wate[ · :~' ' ~ Untreated Wat~: ~ Special Purpose ~. .~: SAMPLE ' ~' '" '~" ., Time ' '; Collected- NO. LOCATI0 N .-? . Collected By L t -- -'~ CITY City -' - aired SAMPLE DATE: red SA~/1PLE TYPE: 1 2 READ i'NSTRUCTIONS BEFORE ~06-~220 {b) BACTERIOLOGICAL WATER ANALYSIS RECORD:, ~ r -- ~': COLLECTING SAMPLE Form No. 18-310 {3-78)_