Loading...
HomeMy WebLinkAboutSKY RANCH ESTATES #1 BLK 5 LT 21 Municipality of Anchorage Page ~ of~ DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: --%L,O q=F(:~ 1"~":7-- PID Number: C~l,..~- Na~.: Wastewater System: ~New D Upgrade A ress: ~o,%o~ ~ ~ ~ ~ ~ ABSORPTION FIELD Pho~ -- ~ ~ ~No.o~edrooms: ~DeepTrench ~ Shallow Trench Died ~Mound DOther Soil Rating: Total Depth from original grade: LEGAL DESCRIPTION ~* ~ ~sq.a. Lot: Block: Subdiv~ion:~ ~ Depth to pipe bottom from original grade: Gravel depth beneath pipe Township: ] Range: [ Section: Fill added above original grade: Gravel length: WELL: D New D Upgrade ~rave~ width~ ~Ft. Number of lines:[ 0islancebetweenli~es:~ Ft. Classification (Private, A,~,C): Total Depth: Cased To: Total absorption area: Pipe material: Driller: Da e Drilled: StalicWater Level: Installer: ~Y~ ; Date instal ed: Yield: Casing Height Above Ground ~ GPM[Pump set at: Ft.] ~ Ft. TANK SEPARATION DISTANCES ~s~ptio ~ Holding ~ S.T.E.P. To Septic Absorption LiS Holding Pubfic/PrNat( Manufacturer: Capacityin gallons: From Tank Field Station Tank Sewer Lines ~ ,~ ~ Mated I: Number of Compadments: Sudace fi I w.t~ t~+ /~+ ~/A LIFT STATION LineL°t ~ * /~t Size in gallons: Manufacturer:/ ~~ ~ High water alarm at: Foundation ~. ~ ~'~ "Pump on' level at: ~ , , ~ , Cu~ain I Remarks: BENCH MARK Location and Description: Assurned Elevation: Inspections pedormed by: &c.~c~o~¢,~. , Dates: 1si ~/'~/** ~ Department of Hea~ an~ ~uman~erv~ces approval :~: 72-013 (Rev. 9/91) MOA 25 F:h~ ~o- ok~,-3~-II~,/ASTEWATER LOT 21, BLOCK 5 100' WELL RADIUS - '\ ]3N SYSTEM RANCH \, EX]ST, WELL WELL THIS AREA UNDEVELOPED, NO WELLS OR SEPTIC WITHIN 200' OF PROPOSED SYSTEM SWING-TIES CD A D T1 13,6 99,2 T2 12,6 98,1 DO 12,7 36.9 C1 12.8 24,2 MT 34,B 13,6 02 52,5 28,5 TANK ELEVATIBN NEW 1,000 NC 10' UTIL, THIS AREA UNDEVELOPED, ND WELLS DR SEPTIC WITHIN 200' DF PROPOSED SYSTEM REPLACEMENT SYSTEM - TYP. SEPTIU o ~ Deep Trench 45,7' Long, 3' WINe, TRENCH PRDF[LE ])ruwlng C,\Work\81-SSKYR,DWG TRENCH SECTIDN 9%4 PREPARED FDR~ Ken Rupper~ 11920 Whispering Spruce CIr, Anchorage, AK 99516 (907) 349-3618 PANNDNE ENG, SVC P, 0, BOX 142025 ANCHORAGE, ALASKA 99514 227-3522, 272-8218 F~x DATE, 9-6-97 IAS-BUILT gCAL~!_ 1'=60' LOCATtOfl: OF WELL ri BOROUOH [.~ SUe~I¥ISIC)jN I LOT BLOCK SECTION QTRS STATE OF ALASKA DEPARTMENT OF NATURAL RESOURCES DIVISION OF MINING & WATER MGMT WATER WELL RECORD SECTION TOWNSHip I RANGE []N F~E E]s E]w MERIDIAN WELL OWNER: DERT ,H~,k~ASURED FROM:[_-Jcasing trip []ground surface BOREHOLE DATA: Depth Material Type end Color From To Dept Health WELL DEPTH: D.pth of ho e:. Depth of casing: DATE OF COMPLETION ft I / DEPTH T~ STATIC WATER LEVEL: /~.1 ftbelow ~[,top of casng [] ground surlace Date: '7 , Z5 / C~'~ METHOD OF DRILLING: '~ mr rotary [] cable tool [] other USE OF WELL: ,~ domestic [] irrigation [] monitor I'"l public supply [] other CASING STICK-J,[P: ~'~ ft. Diem: ~, m. to. tt Casing type: _~__4.~ WELL INTAKE OPENING 'TYPE: '1~ open end ~ screened [] perforated [] open hnle to f~ Depths of openings: SCREEN TYPE: Diam: ,n Slot/Mesh Size: Length: fr GRAVEL PACK TYPE: Volume used: Depth to top: Depth: from ~ ft to ft DEVELOPMENT METHOD: ,'..¢ Duration: PUMPING LEVEL AND YIELD: ft after '~ hfs pumping ~ (~) gpm PUMP INTAKE DEPTH: ft Horsepower: WELL DISINFECTED UPON COMPLETION? [~,YES [] NO CONTRACTOR INFORMATION: egis./~l~ ~lisiness Name . ~J S'~t~re of Aut~dzed Re~presentat~ REMARKS: PLEASE MAIL WHITE COPY OF LOG TO: DNR/DIVISION OF MINING & WATER MGMT 3601C St, Suite 800 Anchorage, Ak 99503-5935 Ph(907)762-2538,Fax(907)562-1384 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF 1 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW970177 DESIGN ENGINEER:STEVEN R. PANNONE OWNER N~24E:NEWF~AN DAVID S & MARJORIE G OWNER ADDRESS:Il920 WHISPERING SPRUCE CIR ANCHORAGE, ALASKA 99516 DATE ISSUED: 7/08/97 EXPIRATION DATE: 7/08/98 PARCEL ID:01530117 LEGAL DESCRIPTION: SKY RANCH ESTATES #1 BLK 5 LT 21 LOT SIZE: 33317 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SANE DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY..'__ ISSUED BY: DATE: ~teven R. ?annone, P.E. Consulling Engineer (907) 272-8218 P.O. Box 142025 Anchorago, Alaska, 99514 (907)272-8218 Fax June 22,1997 Municipality of 3aichorage Dept. of Health & Human Services On-Site Services Section P. O. Box 196650 Anchorage, Alaska 99519 Subject: Lot 21, Block 5 Sky Ranch Subdivision Well and Septic Permit Gentlemen: My firm was contacted to investigate the possibility of installing of a new system at the above referenced property. Currently the lot is undeveloped. A single test hole was excavated on March 8, 1997. The soils report and percolation test results are attached. Ground water was initially monitored for seven days. No ground water was encountered or monitored. The test hole was dry during a site investigation on June 14, 1997. No bedrock was encountered in either test holes. The lot is approximately 1.4 acres in size. Lot 21 slopes to the northeast at a rate of approximately 1 to 2 percent on the western portion, then steepens to approximately 6 or 7 percent. The proposed installation will be located on the southwestern portion of the lot. The proposed location will be greater than 100 feet away from the proposed well serving this property and 25 feet from the water service lines. The surrounding systems are located greater than 100 feet from the proposed installation. The proposed installation will not impact the future development of the surrounding lots. See the attached design. If you have any questions about the proposed installation, please contact me at 272-8218 Sh~cerely, Steven R. Pannone, P.E. Attachments: t DESIGN WASTEWATER A]]SnRPTIIqN SYSTEM LOT 21, :BLOCK 5 SKY RANCH SUB]], I [ I ! /" ?--'---, ',, % \ ".. \ I z ? / \ I I ~/[ WELL ~ ~~ .....~ ........... ~2':::.:=~:~2'2 _ _. TU~ EASEMENT - TYP, / NB ~ELLS DR ~EPT~C ~ITH]N ~00' BF PRDPUSg9 TH~S ~REA UN~EVELDPE9, gY~T~N ND ~ELL~ BR SEPTIC ~ITH~N E~O' BF PRBPD~E9 SYSTE~ 9ES~GN~ Pe~ R~e = 8 NIn/I~ch SoKs= 18B s?/br ~._ ~ 3 Bedroom House ~' OF 27~%-~ 563 SF Rqd -~' "~ 5' Deslgml 5' E?Pectlve ~/ 49~ ~ %~% 3' Wide, 60' Lon9 ~ '"~'~ ....... ~ ~6~lnD C,~o~k~t-SSKYR,9~G To~6t I~~ PREPARED FOR' ~'~ PQnnone EnD, Svc, ,~Steven R. Ponnorle~ &'~/~ ...... : ~ Ken Rupper'~ P, 0, BOX 142025 · ~-.. CE 8149 · %~b ............. C',~.~e Anchorage, AK 99511 "%~-~%~ (907) 349-3618 lATE, 6-8a-97 ~ DESIGN m~m~%~ ;CALE, 1'=60' DESIGN DETAILS WASTEWATER ABSDRPTt~N SYSTEN LOT PL ])LOCK 5 SKY RANCH Z Ld I5 ))r(iwlmg C~\Work\81-5SKYR,I)WG PREPARED FBR' Ken Rupper¢ Anchorage, AK 99511 (907) 349-3618 ino NV393 Pantone EnD, Svc, P, 0, BOX 142025 ANCHDRAGE, ALASKA 99514 272-8218, PHONE & FAX DATEI 6-21-97 DT TD SCALE DESIGN Municipality of ARchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: ~'/L'~.- [/~--.~J '~,..~"~--~r~.~-- DATE LEGAL DESCRIPTION: 1 2 3 4- 5- 6- 7 8 9- 10- Township, Range, Section: SLOPE WAS GROUND WATER ENCOUNTERED? /t~ O SITE PLAN 11 13 14 15 16 17 18 19 2O COMMENTS S IF YES, AT WHAT ~) DEPTH7 p E Deplh l0 Waler After I~onitoring7 ~ Dale: ¢ --/~ ~Y ~ Gross Net Depth ~ o~ Net Reading Date Time Time Water Drop ~'/~/?? ¥.' ~ t ,~ ¢ '/z . ~ .. ~ ~ '/~ '/~ ~., ~ ~ ~ ~/~ PERCOLATION RATE ._ TEST RUN BETWEEN (m~nutes/mch) PERC HOLE DIAMETER ~'(~ FTAND ~ FT PERFORMED BY: ACCORDANGE WITH ALL STATE AND MUNIGIPAL GUIDELINES IN EFFECT ON THIS DATE. 72-008 (Rev. 4/851 CERTIFY THAT THIS TEST WAS PERFORMED IN