Loading...
HomeMy WebLinkAboutSKY RANCH ESTATES #2 BLK 1 LT 1 Municipality of Anchorage Page 1 of 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISIO'N P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW980459 PIDNumber: 015-302-24 Name; Sandy Potter Wastewater System: [] New ~ Upgrade Address: P. O. BOX 111313, Anch., AK 99511 ABSORPTION FIELD Phone: No. of~edrooms:- [] DeepTrench ;z~:ShallowTrench [] Bed Fl Mound [] Other 346-2004 LEGAL DESCRIPTION soil Rating: Total Depfh from original grade: · 4 5 GPO/Sq. Pt. 7 Lot: 8lock: Subdivision: Depth to pipe ~ogom Irorn original grade: Gravel depth beneath pipe 1 1 Sky Ranch Ests #2 3 Ft. 4' Ft. Township: Range: Section: Fill added above originlal grade: ; Gravel ~ength: ~. 100 ~. WELL: 3Publ~c Water Sys[em Gmvelwidth: Numberoflines: Classification (Private, A,B,C): Total Depth: C~ed To: Total absorption area: Pipe material: Ft, FL 1,111 SO. Pt ASTM D3034 PVC Drgle~ Dale Drilled: Static Wafer Level:Installe~ Nor ths tar Date installed: Ft. Earthmov~ r~ 12 / 19.20 / 9 Yield: GPM PumpSetat: Fi, C~ingHeightAboveGtound: Ft TANK Existing SEPARATION DISTANCES ~ptic s Holding S S.T.E.P. TO ~Septic AbsorptionLift HoldingPubli~PH~ate Manufacture~ Capaci~ in gallons: WelY > 200 ' > 200 ' N/A N/A >200 I Material: NumberofCompa~ments: SudaCewater>100' >100' N/A N/A N/A LIFT STATION - N/A Lot > 5 ' > 1 0 ' N/A ~/A N/A Size in gallons: Manufacturer: Line Foundation ,> 5 ' > 1 0 ' N / A N / A N/A "Pump on" level at: "Pump orr' level at: High water slarm at: Cu~ainDrain None on Lo~ PumpMake&Model Electricallnspectionspedormedby: Remarks: Existing Septic Tank was BENCH MARK uncovered, inspected and verified Loca(ionandDescripUon: Front Deck for continued use. 100.0 ENGINEER'S SEAL Inspections peflormed by: A. Ha~ala Dates:lst 12/19/98 Reviewed and approved 72-O13 (Rev. 9/91) MOA 25 Permit No. 2 3 SW980459 Page of Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report LegalDescription: LT 1, BLK 1, Sky Ranch Estates, #2 PIDNo.:_015-302-24. ,.I · , ,_~" ~ .~' i'r,- - -'~- , r_ -._- ?~-~ '- . -- bend '~, . . low. .~ ~ ..~ :. : [' ' ~ ' - sPl~t~,er { ~ / clean outs ~' ~ Cl~ d~verter valve TEE ; I ~, ~ ...... ~,'000 gallon '~ ~ "deck ~ -': s~ept ic tank C3 3 BR house drivewayt I PLAN I ~_l~/. ; ....... ! ..... ~ ,"~--~-~~ ....... aCproX. ~ location of water service - llne AS-BLT 20' 3 3 Permit No. SW980459 Page of "' Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P,O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report LegalDescription: _LT 1, BLK 1, Sky Ranch Estates, #2 PiD No.: 015-302-24 diverter valve flow ; splitter C2 100 LF x 5' W, 4' E. D. absorption trench C .$ 88, BOH= 8 of~ LEGEND: C clean out MT monitor tube ELEVATION AS -BLT 1" = 10" PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4- 5 6 7 8 9- 10 11 12 13- 14 15 16 17 18 19- 20 SP Municipality of Anchorage DF_PARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alasl~a 99502-0650 SOILS LOG -- PERCOLATION TEST Sandy.Potter DATE PERFOF Lot 1 , Block I r Sky Township, Range, Se~ion: SLOPE Ranch Estates No. 1 TESTHOLE NO. 1 COMM~_NTS Perc. WAS GROUND WATER NO ENCOUNTERED? L IF YES, AT WHAT O DEPTH? p E ~2/19/9e SITE PLAN mm~mg? L~one Ill pERCOLATION RATE ''~ ~' irm~utes/mch) PERC HOLE DIAMETER TEST RUN BETWEEN '~"'" .FT AND ~' Fi' Cavity presoaked prior to testing. -- Michael E. Anderson ~/ ,/--.~ ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATF- DATE: /~/ ' 72-008 (Rev. 4/85} Municipality o! Anchora9e DEPARTMENT OF HEALTH & HUMAN SERVICES 825 #L" Street, Anchorage. Alaska 995020650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: LEGAL DE$CRIFTION: 3 5 6 7- 8 9 10 11 13 14 15 16 17- 18- 19 20 Sandy.Potter SP DATE Lot 1, Block l, Sky Ranch Estates No. TESTHOLE NO. 2 Township, Range. Section: I SLOPE I I WA~q GROUND WATER ENCOUNTERED? NO IF YF.~, AT WHAT DEPTH? None 12/19/5 ~ITE PLAN tl [I Same PERCOLATION RATE {~OMME~CTS were ±den[ical [o Testhole No. 1. TFs'r RUN aETWEEN ~. ~T AND m Perc. Cavity presoaked prior to testing. Materials encountered Michael E. Anderson ~/,~/~ ACCORDANCE W~TH ALL ~TA3'E AND MUNICIPAL GUIDELINES IN EFFEC~ ON THiS DAT~ DAT~ ~ 7 ¢ ~ 72~ (R~. 4~} IN MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 995~9-6650 (9O7) 343-4744 ON-SiTE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Dec 08, 1998 Expiration Date: Dec 08, 1999 Permit Number: SW980459 Legal Description: SKY RANCH ESTATES #2 BLK 1 LT 1 Design Engineer: 0014 Anderson Engineering Owner Name: SANDY POTTER Owner Address: PO BOX 111313 ANCHORAGE , AK 99511-1313 Parcel ID: 015-302-24 Site Address: 005001 WHISPERING SPRUCE DR Lot Size: 16875 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [__~ Septic Tank [] Holding Tank [] Privy [] Private Well I~ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Date: ANDERSON/BOUTET 9075226779 12/09 '98 17:31 N0.855 03/03 FAX MEMO To: Dan Roth With: MoA/DHHS From: Mike Anderson Date: December 9, 1998 Subject: Lot 1, Block 1, Sky Ranch Estates No. I Message; We dug two testholes along the west side of the property and found very fine silty sand which percolated just over 30 minutes per inch. We are therefore redesigning the trench for the west side of the property as shown on the attached Site Plan. These soils are better than the ML found in the testhole on the east s~de. We will still place the diverter valve and the splitter valve to enter the new trench in at least two places, We will try to maintain 10' from the old trench, Our testhole uncovered a portion of the old trench and found it to be in excellent condition with all of the biomat gone. We are also trying to maintain 4' above the water level achieved by Mark Pearson in his testhole, The water level In the testhole on the east side is still over 14', We did not encounter any water on the east side, We hope to complete construction in the next two days, Please call me it you have any questions, 3__Pages Being Transmitted ANDERSON/BOUTET 9075~6779 ANDERSON ENGINEERING P.O, B~x 240773 ANCHORAGE, AK 99524, (907) 565-7:155 (907) 337.8855 12/09 '98 17:31 N0.855 02/03 ANDERSON/BOUTET 9075226779 12/09 '98 17:31 N0.855 01/03 East Klatt Road ~ater Sez ~ice Whispering Spruce Drive SCOPE OF WORK: Verify Integrity of Existing Septic Tank. 2. Place Diversion Valve in Existing Service Line. 3. Pl~,ce Flow Splitter Valve at Location Shown. 4. Construct 140' Long x 5' Wide x 2' ~ffective' Depth Absorption Trench at Location Shown. 5. Total Depth of Trench to be 6.5' From Original Ground. SITE PLAN SCALE 1" = 40' December 8, 1998 Municipality of Anchorage Department of Heath & Human Services 825 "L" Street Anchorage, AK 99502-0650 Attention: Dan Roth Subject: Lot 1, Block 1, Sky Ranch Estates Subdivision No. 1 Septic System Design Impacts to Adjacent Properties Dear Onsite Services Engineer: We have revised the design for the septic system upgrade for Lot 1, Block 1, Sky Ranch Estates No. 1 to take advantage of surface area on the property which has not been previously used for the absorption of septic effluent. We have also incorporated the existing absorption bed into the system for use at a later date if necessary. It is hoped the absorption bed will regenerate itself over time and provide absorption capacity in the future. The new design includes the placement of a diversion valve in the existing transport line. It also includes placement of a flow splitter valve and the construction of a total of 140' of 4' wide absorption trench with an effective depth of 2'. The total depth of the trench has been limited to 6.5' even though the testhole recently completed by Alaska Water and Wastewater Consultants indicated groundwater at a depth of 14.5'. The new trenches will be constructed a minimum of 10' from the existing bed and 10' from the eastern property line. We are also limited by the requirement of the 10' separation from the house foundation. Although space is limited, it appears the trench can be successfully placed in this location. Lot 1, Block 1, Sky Ranch Estates No. 1 December 8, 1998 Page Two If the system is constructed as designed the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserved space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern wi be maintained. Sincerely, Michael E. Anderson, P.E. Attachments East Klatt Road 2 Whispering Spruce Drive SCOPE OF WORK: 1. Verify Integrity of Existing Septic Tank. 2. Place Diversion Valve in Existing Service Line. 3. Place Flow Splitter Valve at Location Shown. 4. Construct 140' Long x 5' Wide x 2' Effective Depth Absorption Trench at Location Shown. 5. Total Depth of Trench to be 6.5' From Original Ground. SITE PLAN SCALE 1" = 40' LOT 1, BLOCK 1, SKY RANCH EST. NO. DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home 5' Wide Trench System Perc. Rate: 31 - 60 Min./Inch Verify Existing Septic Tank Application Rate: ,45 GPD/SF 2' Drainfield Rock 3 Bedrooms X 150 GPD / .45 GPD/SF = 1,000 SF of Absorption Area 1,000 SF/5 LF (Width) X ,7 (Red, Factor) = 140 LF Trench Length Therefore: Construct a 5' Wide Absorption Trench System With Two Laterals As Shown on tt~e Site Plan with 2' of Drainfield Rock Beneath the Lateral. Distribution Pipe in Trench Placed at 4,5' Below Original Ground Surface, Flow Splitter Valve and Flow Diverter Valve Required at Location Shown, Mound Over Trenches to Provide Positive Drainage Away From Area. Natural Backfill Geotextile Drainfield Rock NOTE: TYPICAL WIDE TRENCH SECTION (NO SCALE) Grade Area Over Trench to Drain Away, Minimum 3' of Cover over Septic System. Minimum 10' Separation From Lot Line, Minimum 4' Separation From Groundwater. Alaska Water & Wastewater Consultants, Inc. 6901 Debarr Road State 2B - Anchm age ~ Alaska 99504 (907) 337-6179 ~ Fax (907) 338-3246 Cousulting Engiueers November 18, 1998 Municipality of Anchorage Department of Health & Human Services Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Sewer Upgrade for Lot 1, Block 1, Sky Ranch Estates Subdivision #2 To whom it may concern: The existing 3 bedroom house is served by an onsite septic system, and a private well. The existing bed is will not pass an adequacy test and must be upgraded. Commems regarding the proposed upgrade are summarized as follows: 1. GENERAL: As can be seen on the site plan and design, there is limited area to install a new septic system. The site limitations are as follows: · The location of the house · The location of the existing septic systems The location of the water line Given these site restrictions, we propose to install a Innovative Bottomless Intermittent Sand Filter. 2. SOILS: On November 9, 1998, a test hole was excavated and a percolation test was performed in the area of the proposed septic upgrade. As can be seen from the attached log, the soil below the organic layer is a 6 inch GP lense to a depth of 2 feet. At 2 feet, the soil transitions to a SM/SW material to a depth of 3.5 feet and th~'n transition~to a ML material to a depth of 17 feet (bottom of test hole). Ground water was encountered at the time of excavation at 14.5 feet. Two percolation tests were performed between 1.5 to 2.0 feet and 5.0 to 5.5 feet. and determined the rates to be at <1 minute/inch in the upper bench md 60 minutes/inch in the lower bench. 3. TRENCH DESIGN: Bottomless Inte~xnittent Sand Filter (ISF) a. Percolation Rate: <1 and 60 minutes/inch b. Allowable Application Rate for ISF: 2 gallons/day/fi2 c. Number of Bedrooms: 3 d. Design Flow: 450 gallons per day e. Minimum Absorption Area: 225 fl2 f. Effective Depth below pressure pipes: 3 inches g. Width: 10 feet h. Length: 36 feet. i. Effective absorption area -- 360 ft2 (>225 fi2 OK) j. Air Supply: Thomas Industries, Model 5070, "Anchorage Tank". k. Air Supply Line: "Wasteflow" emitterline, 1/2 inch I.D, "Anchorage Tank". 1. Sand Material: G~2ra! PavLng Przduzts "W[-lee-tkottd-Sav~' ~'F~O_ ~w m. Pea Gravel: 100% passing 3/8" sieve, less than 20% passing the 1/4" sieve, and less than 1% passing the #8 sieve. We are proposing to excavate down to a depth of 3 feet (remove all organics), place a m'mimum of 6 inches of sand, install the air supply line, and cover it with 1.5 feet of sand. On top of the sand, we will place 6 inches of 3/8 inch pea gravel, with the pressure laterals midway in the layer. We will use a conventional lift station (Anchorage Tank), equipped with a programmable timer so that flow can be intermittently dosed to the ISF. 4. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 5. TOPOGRAPHY: As cau be seen on the topography site plan, the slope of the lot is at a grade of approximately 5% to 7% running fi'om southeast to northwest. In shorts, there are no slope concerns. 6. MATERIALS AND CONSTRUCTION PRACTICES: The materials used, and the construction practices will comply with DHHS' "Intermittent Sand Filter Design, Installation & Maintenance Manual". The contractor should read this document prior to construction. Copies are available at the Municipal Onsite Services office (5th floor, 9th & L St.). 7. CLOSING: I am open to any suggestions fi'om your department, which would be an improvement to the proposed design. I am unaware of any adverse impacts this installation would have on adjacent wells pr septic systems. If you have any questions, please contact me at 337-6179. Thank you ~ffr your assistance. /I o S '~, ~'~ [NOTE: ALI_ PROPERTIES SHOWN IN E. I(J~l' ROAD .X~,~ ~HI?ERINC SpRU~F A~S~ WA~R AND WAS~WA~ CONS~TANTS, ~C. LEGAL OESCRiPqON: ?~?' 4~ TI~J '..~v~ SKY RANOH ESTATES SUBOIVISION ~2, LOT 1, BLOOK 1, ~..: ..... ~Z~.~,~,.,.:...j SITE PLaN FOR SEPTIO UPGRADE (ISF SYSTEM) ... PREPARED FOR: PHONE NUMBER: SANDY POTTER ( "~ '. ...... '~2~ 11/18/98 J,L.M. 1 = 100' 1 OF 3 I NOTE: THE INTEGRITY OF THE EXISTING SEPTIC TANK IS TO BE VERIFIED. IF OF POOR INTEORI~/, IT ID TO BE COMPLETELY ABANDONED AND A NEW 1250 GALLON S.T.E,P, SYSTEM IS TO REPLACE THE EXIS'~NC SEPTIC TANK --- AND THE PROPOSED 500 GALLON LIFT STATION, I~ISTING EEO TO BE USE[) t~ //~ A RESERVE SITE. LOCATION APPROXIMATE LOCATION OF BED PER SWING-TIES ON INSPECTION REPORt. OF ABANDONED TRENC~ ..... ~1.25 INCH HDPE UNE SLOPED BACK TO ~ m ~' 3'~6~kTM :~!lJlll/%L CE NOTE) mk _:5 ~ I HOUSE L MT~'I~ 13 MT / '"~' ~ /' ~-~_ \ ! INTERMITfENT SAND FILTER OSF) F= / -~ x, I EXOAVATE O' Y DE BY 36' LOND J ~ / ~ ~ / AND ~ FE~ DEEP. ADD 2 FE~ WHISPERING SPRUCE DRIVE PVC JACKET. THE LINE ~HaLL ~E ~U~]E9 TB a HiNiHUH NOTE: THE CONT~CTOR SHALL HAVE THE ~ST PROPERW LINE ]]EPTB I]F a FEET, F~G~ED BY A REGISTEREO I~NO SURV~OR PRIOR TO CONSTRUCTION. ALSO, THE CONTRACTOR SHALL HAVE THE E~CT LOCATION OF THE THE C8~T~SL PANEL ~UB THE STEP TaN~ SH&LL 9E WATER LINE PROFESSIONALLY LOCATED PRIOR TO CONSTRUCTION. PHONE: (907) 337-6179/F~: (BO7) ~38-~246 "' SKY RANCH ESTATES SUBDIVISION ¢2, LOT 1, BLOCK 1, DESIGN OF SEPTIC SYSTEM UPGRADE OSF SYSIEM) PREPARED FOR: PHONE NUMBER: SANDY POTTER 11/18/98 J.L.M. 1 = 40' 2 OF i---A~R Hi~ / AFFI~OK, (HOH~. 9~l~bP~, ANP PbU~HIkI~ PLAN VIEW ~-2" ~ IN~AflON ~AS~ WATE~ AND WAS~WA~ CONS~TA~S, ~C. ' A SKY RANCH ESTATES SUBDIVISION ~2; LOT 1, BLOCK 1 ~[~:' 49Z8~ '"~ BOTTOMLESS SAND FILTER (ISF) RETAIL .. ...... %CANES P WL.AMS~ PREPARED FOR: PHONE NUMBER: SANDY POTTER BATE: O~WN 7320 E. CHEER H~. CIRCLE * ~CHO~GE, AK. ~0504 ' '~-.~ PHONE (907) 337-6179 * F~ (9D7) 33B-3246 ~ " J SOIL LOG - PERCOLATION TEST J~ ~g~uf~ ~/ ',JAMES P, WlLLIAMSt DATE PERFORMED: 11/9/98 ~ *,, NO, 9608 ,: ORGANICS I TEST HOLE ~1I '~(*~A~{t~o,o..,oo?~"<~ DEP~ ~ ..... : ORGANICS/LOAM 2 GP LENSE SOIL C~SSIFICATIONS I~t~$~ SH/SW '~ ' ;~ GW ~ OR6 ~ING SEPTIC ~TEMS "~ ~' I' I ~* ' SILTY S~D TO ,~ :)' ~, WE~ G~ED S~D ~ ~', GPGMGc ~'oLCLML ~ E' K~ ROAD-  E DEPTH TO DATE ML - DENSE SILT GROUNDWATER WITH SIDE WALL 14,5' 11/9/98 SMEARING. BECOMES ~3.5; -"i~i~98 WHISPERING SPRUCE DRIVE DENSER WITH DEPTH _ ~3' ~/~7/~B DATE READING CLOCK NET TIHE WATER LEVEL NET DROP TIHE (HINUTES) READING (INCHES) 1/9~ ~_~L~D 3~_CA~I~ 3 TIMES~I~IED ~CH TIME IF LESS THAN UPPER 10 MIN JTES - WATER DROPPED F~TER THAN 1 MIFUTE/INCH. --B~NCH ] ~ ~.~/9/9E! - PER~._.OLE PRESOI KE~_F~ ?+~ )U.R~RIO~ TO ~ LO~ER 1 fi',05 ......... JIi/ B,O,H, ..._. 5 5:0Z_ .......... 6" . 6.. 5.,~7 50 MIN. 5 1/2" 1/2" . PERCO~'FION ~TE <1/60 (NIN,/INCH) PERC, HOLE DIA, 6" (INCHES) 20~ TEST RUN BE~EE~ 1.5-2.0 FT. AND 5,0-5.5 FT, PERFOMED BY A~SKI WATER · WAST~ATER I,C~,~ X~~' , CERT'~ THAT THIS WAS PERFOR~EEIN ACCORDANCE WITH ALLI~TE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DEPTH TO DATE GROUNDWATER ~4.5' _ ..~1/9/98 13.5' 11/10/98 13' 11/17/g8 D~C-1~-~998 15~59 MMC CONSTRUCTION INC 522 53?3 P,O1 · I' · TOTAL P.01 Municipality of Anchorage Page _ DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: $~]q'Z..,o'?~5~ PID Number: ~1~' ~0 2--'Z-L'~- Name:~p~ ¢O~t ~ Wastewater System: ~ New ~Upgrade · ~d~s¢.o, ~X ll{~ /~/~, ~q~tl ABSORPTION FIELD Phone: ~--~O~ [No %edrooms ~ Deep Trench ~Shallow Trench ~Bed ~Mound ~Other To,al Depth from ori%~de: LEGAL DESCRIPTION S°ilRating: ,¢ GPD/S, Ft; Lot: Block Subdivision: )epth to pipe bottom from original grade: Gravel depth beneath pipe I I ~¢~~ ~,~ F~ '~ Ft Ft ~ Ft Number of lines: I Distance between lines: WELL: E] New Q Upgrade ~ravelwidth: ~OFt ~[ ~ Ft. Classification (Private. A.B,C); Total Depth: Cased To: Total absorption area: Pipe msterial: Driller: Date Drilled: Static W~ter bevel: Installer: Dale installeo ~: SEPARATION DISTANCES ~Septic [1 Holding U S.T E P. Water ~ .__ . LIFT STATION LiRoL°t ~ I [~[ ~ Size~in ~allons: [ M~u~act~ror: kocation and Desedption: tf * /.' ,': Inspoctions pefforme0 by: ~~ ~a,~ Dates: ~st t~ ,q ~ Department of Heal and Hu ervices apprgval/ ~..:'-.~.-" ...... .,.....,,.,. . Reviewed and approved by _ ~ Date: '<~' 72-013 (Flev 9/91)MOA25 / Permit No. %~'¢ Page of Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: ~J¥-"( ,D. PaqOH- ~¢"U ~'7_[ bo"i- I/fCppg¢-- I PID No.: CO'~Z 7--'¢,'~ q,~ CO CO 72 013A (Rev 9191) MOA 25 PermitNo, ~W'~. O¢_..~z~ Page '~ of '~ Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: PID No.: 01~' 105 ~0 05 O0 ~5 9O 72-013 A (Rev. 9/91) MOA 25 PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW920283 DESIGN ENGINEER:MOUNTAIN ENGINEERING OWNER NAME:POTTER SANDY K OWNER ADDRESS:3868 SHANNON CIRCLE ANCHORAGE, ALASKA 99508 PARCEL ID:01530224 DATE ISSUED: 9/14/92 EXPIRATION DATE: 9/14/93 LEGAL DESCRIPTION: SKY RANCH ESTATES #2 BLK 1 L T 1 LOT SIZE: 16875 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. AL1, REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80). 3. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ~~ DATE: ISSUED BY: ~_~a-~_~ ~m-~ '-f~4~ ~-- DATE: MOUNTAIN ENGINEERING 3868 Shannon Circle Anchorage, Alaska 99508 (907) 562-1500 September 8, 1992 Municipality of Anchorage On-Site Services P.O. Box 19-16506 Anchorage, AK 99519 Dear Sirs: Re: Skyranch Estates #2, Lot 1, Block 1 Owners - Sandy and Brad Potter MUNICIPALITY OF ANCHORAGE ENVIRONMENTAl. SERVIcEs DIVISION SEP 0 ,~ 1~92 RE'CEIVED The purpose of this letter is to provide the required design narrative in support of our application for a permit to upgrade the septic system on 'the above referenced lot. Attached for your reference are the soils log, percolation test results, a land surveyor's site plan, and design drawings. The existing drainfield on the lot has failed, and overflows periodically on the surface. We performed a soils log and percolation 'test at the location indicated on 'the design drawing. The resultant percolation rate was 12 mtn/inch. Groundwater rose to 10.6 FT from the existing grade during the Groundwater monitoring period. Design was therefore limited to a bed in order to maintain the Groundwater separation and to provide the grade necessary for gravity flow. The application rate was .5 GPD/SF. The house has 3 bedrooms, and the required absorption area is 3 X 150 / .5 = 900 SF.~We have elected to use a bed size of 23 FT X 40 FT. The topography of the lot in the vicinity of 'the proposed bed slopes towards the north at 1% 'to 2%. The house is on a community water system, and there are no wells within 200 FT of the proposed system. Please contact me at 562-1500 if you will need any additional information. Sincerely, MOUNTAIN ENGINEERING Mark Pearson, P.E. Z I' /3 ~, 04 L I herlby certify that I have lurvayed the following delcrlb~d property, Lot / Block / i ; _,~/~ ~..t6~ICFI EU:'F~.'~51UklIT ~ Anchora~ recording Precinct, Alelks, and thst [ the improvem~tl mltuated th~r~n ~re within the property linem and do not overlap or i ' L Book No, ~ No, PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST 6- 7 8 9- 10- WASGROUNDWATER ENCOUNTERED? 11 Township, Range, Section: 13- 14- 15- 16- 17 18 19 2O I SLOPE IF YES, AT WHAT SL DEPTH? [[/ pO E Deplh Io Water Alter ~:~/~,_~_.,~ Monitoring? JO~! Dale: . SITE PLAN Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE [J' ( (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~2~ FTAND "~ FT COMMENTS PERFORMED DY: ~ a"~U~/~,~¥, I ~¢*~ CERTIFY THAT THIS TEST WAS PERFORMED IN 0 ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~JJ.~CJ ~. 72-008 {Rev. 4/85) DEPARTMENT OF HEAL'rH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE [] NEW MAILING ADDRESS Well ~ Absorption area Dwelling PERMIT NO, Liq, capacity in gallons ' Inside length ' Width Liquid depth IF HOME.DE: ~Z DISTANCE TO: ~ ~ ~ Manufacturer Material -- LiqUid capacity in gallons Q Wel~-~ Foundation ~ -- Top of tile to flni~h grade ~ Material beneath tile ~ ~ Type Cdb d ~te]' Drib epth Total effective absorption area ~ Well Building foundation Nearest lot line ~ DISTANCE TO; ~ ~l~ss Depth Driller Distance to lot line PERMIT NO, ~ DISTANCE TO'. Building foundatio~ Sewer line Septic tank Absorption area(s) OTHER SOIL TEST RATING RfiMARKS . ~, ~ '~,.. 'L... 72-013 (Rev. 3/78) - ' L,F. Zi3 F:II, II..,I:.~'L.II ]:::IR I::,P.I::I..I I III Tt.'l[=i t,..Ei'.,II3TH E:,IMEi'.,I'.k.:i!h:)N "c; TFIE L.Ei'.,IGTH ,:lin I'=IEET', 3F 'I'I:IE: '~' -'~ "=' =' F' '1'1"1[~i E:,EF'TH 'iF:' I:':1 TI;dEN, CH "f::' F:.. I I:!i[~'.l:)l..li",ll::, I::1'~"1[:' THE [~:l:]T't"l']['i f.]F: THE [!:;:':',I::FI'v'f::FI']:O~',I ,' ':': .... FF,:.Eil`1 'f'I~IE[~:[E :1:'.~: .i",l(:.~.~ .:L.t H'.I:D'f'H F::]P ' :'" '''' ;:'= THF=' "::' ,' - T~-"--" " " ~f. 1-1, f .I. ii:fiEF'TH .. ::, T H~:;. ~'13:I".11 i'"ll..li'"l E:,[~:E:"I"H OF" ('iiEE'.I::I;,,'~].. [~:1:}_ I'!.,.I~:~Ei:[",I I"HF: OU'I"FI=tl .!. t'. I' I F::ll",lt) THE l: '; TT "' f"l OF:' TI4E ................... ,:: - - .f,-,.. . c .......... , I1-1:~ :, I::,EPf:II;;'.TI',~EI'.`1T I::,l. ll;;'.:l:l'.,t(!i F'I~:P.I,i]:'i ~ f I .-I-,11 Ht ... 'l'l. ll:i: h.f..._f _I,!..:I.L.[I,,I I r "1'-i IhlI='(:U;~',F'I ....... 1:~ I I [. I I=lhll::, 'FltlE II'4'.STFILI..f:ITI':ff.I IH::,t E .fi ~.,!::, OF FIN'./ Ilf.LL:, RD.]T~CIENT TO TI.I:['.:)~; "; ..... I'.~I. IHE~EI;?. OF RI:.:,.II [:N .t .... 'FHF:IT THE I,E~I.I.. !.411_1 ..... L.I..,L i1~ CEI:;;'.'I'I'F'¢ THRT :1,: I FIM F'FIIVI:II..IFIF:', I.,,IITH Tt,IE [~:E6!U:[REI'IEhFI~; FOI?. ON,,..d~; :I: TI:: ~:;E!,IEI;?.~ AND !,1[~:1.1.~; F:E~; I::;[)F;I'H D"r' THE F'IL.II'.`1:IC]:I::'FII.ITV JIF; AI.,ICHORA[3E. 2: I I,.IlL. I... ~F`1',E;"I'f:IL.L. THE ',~'¢~TE~3"i :1~1',,I FICCORDF]NCI~ Hi[TH THE :]~: :1~ I.JF,II::,E-:I;i',~TFINC, THFIT THE ON--'~:~;~'I'E~ ~EI4E:I~: ~;V'.~;TEH HF:I"r' I,~Ep~U:I:I;'.I~: F,:tql,ARdi[~:FIEq",!T ,1:1=' Till:.: ..:, .I. CiNED: AFF'L ~C~:~N'I" I.m=~F~.~..r %I',IlTH~,.I:I:CK GREI ANCHORAGE AREA BOE JGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME LOCATION ~'f~, "'Ll-'¢ LEGAL DESCRIPTION SEPTIC TANK: DISTANCE FROM WELL INSIDE LENGTH M A N U FAC T U R E R-~. ~-/¢~',~ ~---~ 7-~'~.~. MATERIAl NUMBER OF COMPARTMENTS INSIDE WIDTH LIQUID DEPTH .LIQUID CAPACITY ,/~'-f)~ GALLONS. SEEPAGE Pit: NUMBER OF PITS /, DIAMETER OR WIDTH LINING MATERIAL~C'~'-¢"/~/'g//4/ CRIB SIZE: DIAMETER BUILDING FOUNDATION NEAREST LOT LINE ADDITIONAL ABSORPTION LENGTH DEPTH DEPTH "'] / DISTANCE FROM: WELt TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) SO, FT. WELL: TYPE ~:~ .4./f'--/. CONSTRUCTION BUILDING NEAREST FOUNDATION __ LOT LINE CESSPOOL OTHER SOURCES APPROVED DISAPPROVED NEAREST SEWER LINE REMARKS DEPTH DISTANCE FROM: SEPTIC SEEPAGE TANK SYSTEM DISTANCES: INSTALLED BY: ~./~¢.16¢-- ~C, PIPE MATERIAL: LOT SLOPE: REMARKS: '~-¢' ~',.~ Form NO, EQ-031 DIAGRAM OF SYSTEM ,~.~.~ / c. .?- / D /`7/ DATE APPROVED /~'f"¢~¢'~'~ G.A.A,B, GREATER ANCHORAGE AREA BOROUGH SEWAGE DISPOSAL SYSTEM -- APPLICA'rlON AND PERMIT PERMIT NO. INSTALLATION OF: SEPTIC TANK SEEPAGE PIT ., DRAIN FIELD P'N^NCEDTH"OU " F"¢C TO"E '"STALLED"" Zf; OTHER NOTE~ THI~ PERMIT IS i~OT VALID wI'rHOUT ~OIL, TE~T FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILL. lNG OF ANY SYSTEM WITHOUT FINAL INSPECTION bY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION, TYPE SEPTIC TANK --0 SEEPAGE PIT TO NEAREST LOT LINE, WELL TO SEPTIC TANK C~OC~ '~-- DRAIN FIELD WATER MAIN TO SEPTIC TANK DRAIN FIELD SEPTIC TANK, /'00 , SEEPAGE Pit TO RIVER, LAKE, STREAM· FOUNDATION TO SEEPAGE PIT , SEEPAGE PIT DRAIN FIELD 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIO TANK AND SEEPAge PIT FITTED WITH Al RTIGHT REMOVABLE CAPS. GRAVEL, BACKFILL CONFORM TO BOROU~I] REGULATIONS ~EGARDING INSTALLATION, I' I CERTIFY THAT [ AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA [~OROUgH ORDINANCE NO. 2B-§8 AND THAT THE ABOV' DESCRIBED SYSTEM IS IN ACCORDANCE W]TH SAID CODE. Performed For Glacier Excavating __Date Performed ~-IT-TLF Legal r)escrintion: Lot I Block. l,~___Subdivision__~k~_~.anch Percolation Test This Form Rep,errs Soils Loq yes Oeoth Feet Soil Characteristics Inlet T~ Seepage Pit Silty Sand with 2 ft. layer of Gravely Sand SW & SM 210 7.i~__~Bottom of Seepage Pit 8-- 11 ~:----' Bottom of test pit Was Ground Water Encountered?_N° I¢ Yes, At what Depth? [--R e a d5 n-~. [ T. Percolation Rate Proposed Den, th of CF~!AENTS: Date Gross Time Net Time Depth to H20 · Minute Inst~OH: SeenaQe Pit yes Drain Net Dron Field Inlet __ Deoth ~ Bot'~om Of Pit Or Trench drains~e area ~required~j~_er bedroom_ 210 ~,.qL._~.ft. ---- ,o ..... ' --- ~ no_bed?OO~ or--Mg~-b-~jO--~e~ ~_fb~_be]:9~ ~eep_~ Data Certified B~:_~s_~_b;cjx~J_o~.-~e~bl Test Performed By Jim Mack ---- Date' 5-I7-7~- . ...... MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O, Box 196650 Anchorage, Alaska 99519-6650 343-4744 P~rcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 015-302-24 HAA# '~ 1. GENERAL INFORMATION Complete iegal description Lot 1r Block lr Sky Ranch Estates No.~?~,% Location (site address or directions) 5001 Whispering Spruce Drive Property owner Mailing address Lending agency Mailin. g address Agent Address S~ndy Potter. P.O. Box 111313 Day phone 346-2004 AnchorageCAK 99511-1313 Day phone Day phone. Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: Three 3 ) .. TYPE OF WATER SUPPLY: Individual well Community well ××x Public water · NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: XXX If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025(Rev, I/91) Fronl MOA#21 ~ STATEMENT OF INSPECTION BY ENGINEER AS certified by my seaJ affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Mun[cipa]ity'of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. NameofFirm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 AnchoraGe, AK 99524 DHH/S SIGNATURE ~/' Approved for '~.~ Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: AdditioneJ Comments The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DH HS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Legal Description: A, WELL DATA Well type PW$ Log present (Y/N) Total depth Sanitary seal (Y/N) of Anchorage R Municipality DEPARTMENT OF HEALTH & HUMAN SERVICES Environmental Services Division 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 3.43-4.7.44. Health Authority Approval Checklist Lot 1, Block 1, Sky Ranch ParcellD.: 015-302-24 Estates No. ~k Public Water System If A, B, or O, attach ADEC letter. ADEO water system number Date completed. Cased to Casing height (above ground) FROM WELL LOG Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform Date of sample: B. SEPTIC/HOLDING TANK DATA Date installed 1 992 Foundation cleanout (WN) Date of Pumping 9/98 C. ABSORPTION FIELD DATA Date installed 1 2 / 98 Wires properly protected (Y/N) AT INSPECTION Nitrate g.p.m, g.p.m. Collected by: Tanksize 1 ,000 Number of Oompartments 2 Y Depression (Y/N) N _Pumper Rotc Rooter High water alarm (Y/N) N Other bacteria Length. 1 00 ' Width 5 ' Effective absorption area 1 , 111 Date of adequacy test Hew Const, Fluid depth in absorption field before test (in.); Fluid depth (ins) Minutes later: Peroxide treatment (past 12 months) (Y/N) 72-026 (Rev. 3/96)* __ Cleanouts (Y/N) Y System type5 ' Wide Trench 4 ' Total depth 0 ' _ Depression over field (Y/N) N For Three bedrooms gal. water added (in.): _ __ .g.p.d. Soil rating (g.p.d./fF or ff~/bdrm) .45 Gravel thickness below pipe. Monitoring Tube present (Y/N) Y Results (Pass/Fail) Pass Immediately after Absorption rate = N/A If yes, give date F. LIFT STATION Date installed - None on Lot Manhole/Access (Y/N) High water alarm level at* Cycles tested SEPARATION DISTANCES Size in gallons "Pump on" level at* *Datum SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot Absorption field on lot Public sewer main Sewer/septic service line SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Foundation > 5 ' Property line > 5 ' Water main/service line > 2 5 ' Surface water/drainage > 1 0 0 ' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO: Property line > 1 0 ' Building foundation > 1 0 ~ Surface water > 1 0 0 ' Public Water System On adjacent lots On adjacent lots Public sewer manhole/cleanout Lift station "Pump off" level at* Absorption field ;, 5 ' Wells on adjacent lots > 2 0 0 ' Water main/service line Driveway, parking/vehicle storage area > 1 Curtain drain None on Lot Wells on adjacent lots > 200 ' ENGINEER'S CERTIFICATION I certify that I have in conformance with MOA HAA guidelines in effect on this date. Signature ~ ~',_~,~t,..~--_..,, '~'~ Engineer's Name Michael E. Anderson, P.E. Date 3/5/99 HAA Fee $ ?-~, ~-~,~ Date of Payment ~ ~% Receipt Number ~L~--~\-~ ~ 72-026 (Rev. 3/96)* Waiver Fee $ Date of Payment Receipt Number MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH& ENVIRONMENTAL PROTECTIOI~EpT. OF HEAL'rll & 825 L Street- Anchorage, Alaska 99501 ENVJP.!)NMEN, TAL pF, OTEC.~TJON ENVIRONMENTAL ENGINEERING DIVISlON,~~--1980'- Telephone 264-4720 \'"~'/~_ _ _ i)IRECTIONS: Complete al parts on page 1, Incomplete requests will not be processed. Please allow ten (I01 days for processing, 1. PROPERTY OWNER PHONE~is Larry & Sharon Smi~.hwick WK- 349-3536 V1AI LING ADDRESS SRA BOx 1622K, Anchoraqe, AK PROPERTYRES~DENT If different from above) same 99507 PHONE PHONEher WK- 264-6591 2. BUYER rl~eodore & Sandy Potter MAILING ADDRESS 6802 E. 12~aAvenue, Anchoraqer AK 3. [.ENDING INSTITUTION United Bank Alaska 99504 PHONE 276--1911 ×210 MAILING ADDRESS 645 G Street, Anchoraqet Alaska 4, REAL'I'OR/AGENT ~/a 99501 MAILING ADDRESS PHONE E. LEGAL DESCRIPTION Lot 1, Blk 1, Sky Ranch Estates STREET LOCATION ~\ NHN Whispering Spruce Drive S. TYPE OF RESIDENCE SINGLE FAMILY [] MULTIPLE FAMILY NUMBER OF BEDROOMS [] One [~ Four [] Two [] Five [] Three [] Six [] Other 7, WATER SUPPLY [] INDIVIDUAL~ * ATTACH WELL LOG, Awel o§ s required for all wells driHed [~ COMMUNITY since June 1975. For wells drilled prior to that date, give we [] PUBLIC UTILITY ~e~th (attach og if available.) 8, SEWAGE DISPOSAl. SYSTEM [] NDIVIDUAL ~ON-SITE*- ~' f individual/on-site, give installation date -~ - ~[~ '~ ~ q-¥~l If system is over two (2) years old an aueouacy test is required t.J. [] ~UBLIC UTILITY Dy [nls Department, NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED, 72.010(3/78) THIS SIDE FOR!OFFICIAL USE ONLY DATE RECEIVED INSPECTION APPOINTMENTS TiME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR I NSP ECTOR DIRECTIONS: 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] ONE [~ THREE [] FiVE [] OTHER SINGLE FAMILY [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL ~ COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER '~]INDIVIDUAL/ON -SITE DATE INSTALLED ii]PUBLIC UTILITY [._~[3~d~]) '~_ ~.o~_ -~o~ Connection Verified INSTALLER ~Septic Tank or [~] Holding Tank Size:~ If Tank is homemade SOILS RATING give dimensions: TYPE OF TANJ~ ~t~ MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES WELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS ~ APPROVED FOR .3 BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) DATE ~ DISAPPROVED BY (Title) LEGAL DESCRIPTION 72-010 (Rev. 3/78)