Loading...
HomeMy WebLinkAboutSKY RANCH ESTATES #2 BLK 1 LT 7 Municipality of Anchorage Page ! of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-.4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: 970~,?¥ PID Number: Name: ~h~,~e/~ ~ ~e I~e~ Wastewater System: ~ New ~ Upgrade Address: ~. ~o~ u~z~, ~o~ ~ ~// ABSORPTION FIELD Phone: I NO, of Bedrooms: ~ ~' ~-Y~I ~ ~ Deep Trench ~ Shallow Trench ~ Bed D Mound ~ Other Total Depth from original grade: Lot: elock: Subdiv~ion: Depth to pipe bottom fro~ original grade: Gravel depth beneath pipe Township: I Range: I ~ection: Fill added above origi,al grade; Gravel length; D New ~ Upgrade Gravel width: Number of lines: lDistancebetwee~Tines: WELL: Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material: ~.~/~ Yield: GPM ~ PumpSet at: Ft. Icasing Height Ab°ye Gr°und:Ft. TANK SEPARATION DISTANCES ~Septic U Holding U S.T.E.P. To Septic Absorption Lift Holding Pubti~/Private Manufacturer: Cap~city in gallons: From Tank Field Station Tank SewerLines ~O~ T~n ~ Material: Number of Compa~ments: sud~o~ LIFT STATION Foundation CudainDrain ~ ~ - Pump Make & Model Electrical Inspections performed by: Remarks: ~+~ ~ ~/ ~¢~ ~o~,~ BENCH MARK ~ ~0~ /O~,~ O~+y-~ ~ LocationandDescriptiom nspect'onsperformed by'. ¢/¢~. %e~ %uc Dates: 1st ~/11/)7 ,¢j.,~,,~,,. .......... Department of Health and Human Serwces approval ,~,,~, ,,, Reviewed and approved by: //¢ L', t~,~ Date: lo.zI .CLX. 72-013 (Rev. 9/91) MOA 95 PERMIT NO: SW970294 PID NO: 01530218 41'TRENCH ---SEGMENT PAGE 2 OF 2 SEGMENT DBL. C.O. 1000 GALLON SEPTIC TANK 23'TRENCH SEGMENT RETAINING "G" WALL .-,, ; SWING TIES: FROM: COR."A" COR."B" COR."C" TO: S.T. C,O, "D" 22' 26' S.T.C.O. "E" 21' 32,6' DBL, C,O. "F" 20.5' 35' TR. C.O. "G" 36.~;' 34.6' TR. M.T. "H" 37,5' 36.,5' TR. C,O. 'T' 65' 45.§' 82.5' TR. M.T. "J" 66,§' 47' 84' LOT 7, BLOCK '1 SKY RANCH EST. #2 PLAN VIEW SCALE: 1" = 30' WHISPERING SPRUCE DRIVE (4'+ SOIL COVER) EXC. ELEV. 85.0' BOT, T,H, #1 ELEV. 79,0' M.T, DRY 9/11/97 PROFILE VIEW NOT TO SCALE 94.0' 1000 GAL, SEP. TANK 94.2' L7, BLK 1, SKY RANCH EST #2 SEPTIC SYSTEM UPGRADE AS-BUILT INSP. REPORT FLATTOP TECIINICAL SERVICES 14530 ECIIO STREE'r ANCHORAGE, ALASKA 99516 SCALE: AS NOTED DRAWN BY TFM SEPT. 1997 PAGE 1 OF MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 A/qCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW970294 DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES OWNER NAME:AWE ELIZABETH JUNE OWNER ADDRESS:5201 WHISPERING SPRUCE DR ANCHORAGE, AK 99511 DATE ISSUED: 9/05/97 EXPIRATION DATE: 9/05/98 PARCEL ID:01530218 LEGAL DESCRIPTION: SKY RANCH ESTATES #2 BLK 1 LT 7 LOT SIZE: 18125 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) {NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SANE DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. 2 SPECIAL PROVISIONS: 1. THE EXISTING LOG CRIB WILL NEED TO BE PROPERLY ABANDONED. 2. PER AMC 15.65.060, THE PROPOSED DRAINFIELD NEEDS TO MAINTAIN A MINIMUM OF 10 FT SEPARATION DISTANCE TO WATER/ SERVICE LINE. 3. PER AMC 15.65.060, THE PROPOSED DRAINFIELD CANNOT BE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 CONSTRUCTED UNDER ANY STRUCTURE. RECEIVED BY: ~-a~ ~ DATE: ISSUED BY: DATE: PAGE 2 OF 2 ? 1~-177 Rick Mystrom, Mayor Mtmicipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 September 5, 1997 Ted Moore, P.E. Flattop Technical Services 14530 Echo Street Anchorage, Alaska 99516 Subject: Waiver Request for Lot 7 Block 1 Sky Ranch Estates #2 Waiver Request #WR970049, PID #015-302-18, SW970294 Dear Mr. Moore: Your request for a waiver of the required 10 foot separation between an on-site wastewater disposal system and a lot line has been approved. The waived distance is 3 feet from the leachfield to the west property line. This approval applies to the existing on-site wastewater disposal system lot line separation only. Any future upgrade to the on-site wastewater disposal system will require all separations be met or another approval from this department. If there any further questions or concerns regarding this waiver, please call our office at 343-4744. Sincerely, Civil Engineer On-site Services ljw #7 Kjers WR# WR970049 Date Received: Legal Description: Lot 7 Block 1 Sky Ranch Estates #2 Engineer: Ted Moore, P.E., Flattop Technical Services MUNICIPALITY OF ANCHORAGL Department of Health and Human Services On-site Services Section Waiver Review Worksheet PID# 015--302--18 HA# August 19, 1997 Permit 14530 Echo Street, Anchorage, Alaska 99516 Applicant: Brian & June K~iera Waiver Requested: Lot line waiver of leachfield to the west property line of 3 feet Criteria: 1. Geology: Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation TOTAL: 2. Special CondiCions: 3. Other: Waiver is Granted: ~ List Conditions or Reasons Waiver is NOT Granted: for above: By: Name of ReViewer Rec #: #03146 Amount: $ 115.00 Date Paid: August 19, 1997 CIVIL & ENVIllONMENTAL ENGINEERING * ENERGY CONSERYA'IION & ANALYSIS TIfEODORE F. MOORE, P.E. 14530 ECHO ST. PH: (907) 345-1355 ANCHORAGE, ALASKA 99516 August 18, 1997 M.O.A. DHHS P.O. Box 19-6650 Anchorage, AK 99519 Dear Sirs: The purpose of this letter is to provide the required design narrative in support of our application for a permit to upgrade the wastewater disposal facilities on Lot 7, Block 1, Sky Ranch Estates, Unit #2. Soils logs, perc test results, a site plan, design drawings and specifications are enclosed for your review. The proposed system will be constructed in the vicinity of test hole # 1. As can be seen from the soil log, the native material between 7 and 15 feet below ground level is a somewhat silty fine sand with. a measured perc rate of 5 minutes per inch. Using a conservative soil application rate of 0.6 gpd/sq, ft., this 3 bedroom residence requires a total absorption area of(3 x 150)/0.6 = 750 square feet. The proposed 82 foot long trench design with 5 feet of sewer gravel beneath the distribution pipe has a total absorption area of 820 square feet. In order to maximize the separation distance from the existing log crib seepage pit a lot line waiver is requested allowing the soil absorption trench to be located 3 feet fi'om the west property line, common with Lot 6. Because the lots in this subdivision are served by a community well and the existing septic system on Lot 6 is approximately 75 feet away, granting the requested waiver will have no significant effect on the ability to construct replacement systems on Lot 6, when that becomes necessary. The topography of the lot in the area of the proposed construction is fairly level, with an estimated 2% average slope to the west. The proposed project will have no significant impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any significant impact on reserved space-surface and subsurface, or on drainage. Please give me a call at 345-1355 if you have any questions on this submittal. l',4UNIc~r,~,,[.l £y Or ANLi IO,~AGC EN"/IRONMENIAi. SERVICes DIVISION AUG ,9 997 Sincerely, Ted Moore, P.E. UNSUBDIVIDED LAND #1 CONSTRUCT 82' LONG SOIL ABSOPTION TRENCH WITH 5' SEWER GVL. BELOW DIST PIPE LOG CRIB ,_SE_E_PAGE PI_T, SEPTIC SYSTEM INSTALL NEW ,, 1000 GALLON ~J~ 1 SEPTIC TANK HOUSE LOT 6, BLOCK /o \ RETAINING WALL ABANDON EXIST. 1000 GALLON SEPTIC TANK SEPTIC o SYSTEM o HOUSE LOT 7, BLOCK 1 LOT 8, BLOCK 1 WHISPERING SPRUCE DRIVE LOT 16, BLOCK 2 LOT 17, BLOCK 2 NOTE:RESIDENCESIN THIS SUBDIVISION ARE SERVED BY A CLASS'W'COMMUNITY WATER SYSTEM LOT 7, BLK. 1, SKY RANCH EST. #2 SEPTIC SYSTEM UPGRADE SITE PLAN FLATTOP TECIINICAL SERVICES 1 INCH = 50FEET 14530 ECHO STREET DRAWN BY TFM ANCHORAGE, ALASKA 99516 AUGUST, 1997 NOTE: THIS IS NOT A SURVEYED PLAT. ALL LOCATIONS SHOWN ARE APPROXIMATE. -/ ~,~ MONITOR 4" D-3034 (TEE INTO PERF PIPE L~ NO MORE THAN 50' FROM END~ CONSTRUCT 82' LONG ,,~ ~SOIL ABSORPTION TRENCH WITH 5' SEWER GRAVEL BELOW DIST. PIPE DBL. C.O. PLAN VIEW SCALE: 1" = 10' - 0" INSTALL NEW t000 GALLON SEPTIC TANK CLEANOUT MONITOR TUBE 3 1 MOUND COVER MATERIAL 12" SECTION "A - A" SCALE: 1" = 5' - 0" ORIGINAL GROUND FILTER FABRIC 4" DIA. F-810 PERF. DIST. PIPE 1/2" SEWER GRAVEL BOTTOM OF EXCAVATION LT, BLK, i, SKY RANCH ESTATES #2 SEPTIC SYSTEM UPGRADE PLAN AND CROSS-SECTION FLATI'OP TECHNICAL SERVICES 14530 ECHO STREET ANCHORAGE, AK, 99516 SCALE: AS SHOWN DRAWN BY: TFM AUGUST, 1997 Flattop Technical Services 14530 Echo Street, Anchorage, ,~[( 99516 Phone (907) 345.1365 Lot 7, Block 1, Sky Ranch Estates, Unit #2 5201 Whispering Spruce Drive Wastewater disposal system instqllation Specifications 1.0 General: 1.1 The scope of the project consists of abandonment of an existing septic tank and log crib seepage pit and installation of a new 1000 gallon septic tank followed by 82 lineal feet of soil absorption trench with a total of 5.5 feet of sewer gravel. 1.2 Construction shall be as depicted on the approved site plan and design drawings. Depending on site conditions, minor deviations from these drawings may be allowed or required by the engineer conducting the inspections. All construction procedures and material specifications shall conform with Mmficipal and State requirements. All separation distances shall be in conformance with Municipal requirements, unless specifically waived. 1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any buried utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is achieved after settlement and that there are no residual depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the construction. 1.6 The homeowner shall be responsible for arranging to have the storage shed in the area of the proposed trench temporarily relocated during cons#'uction, and shall also arrange for a land ,~trveyor to locate the northwest property corner and place stakes marking the north and west property lines at points 50feet away from the northwest corner. 2.0 Septic Tank: 2.1 The existing septic tank and seepage pit must be properly abandoned by thoroughly pumping, removing their tops and backfilling with soil. For the septic tank, this may entail temporarily shoring up the existing deck and/or installing new supports. 2.2 The new 1000 gallon, 2 compartment septic tank shall be Municipally approved and shall be set level on undisturbed soil. Each compartment shall be equipped with a watertight manhole cover and a 4" cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial type, rigid insulation. 2.3 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The waste line from the residence to the septic tank shall have a minimum slope of 1/4'" per foot, and the waste line between the tank and the soil absorption system shall have a minimum slope of 1/8" per foot. A cleanout shall be installed within 5 feet of the building foundation, and a double cleanout shall be installed within 5 feet downstream of the septic tank. 3,0 Soil absorption system: 3.1 The soil absorption system shall be constructed by excavating an 82 foot long trench to a total depth of 12 feet below original ground level in the vicinity of test hole #1. 3.2 The bottom of the excavation shall be level. Any compacted or smeared surfaces shall be raked to allow proper infiltration. Sand for leveling or serving as filter material shall comply with Mmficipal specifications. 3.3 A total of 5.5 feet of approved sewer gravel shall be placed in the bottom of the excavation with the perforated distribution pipes laid level such that the pipe inverts are no less than 5.0 feet above the bottom of the sewer gravel. Sewer gravel shall be 0.5" ~ 2.5" screened gravel, with less than 3% passing the #200 sieve. 3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on the design drawings. The portion of the monitor tube extending through the sewer gravel shall be perforated. 3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. A minimum of 2 feet of soil cover is to be placed over the filter fabric. If the soil cover thickness is less than 3 feet, two inches of rigid, burial type insulation is to be placed over the entire top surface of the gravel, in addition to the filter fabric. 3.6 The top surface of the cover material shall be raised a minimum of 12 inches higher than the surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill slopes shall be no steeper than 3:1. 3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to have the site finish graded after the backfill material has stabilized, and for placement of adequate topsoil and seed to promote rapid revegetation of all areas disturbed by the construction. 4.0 Inspections: 4.1 Aminimum of 4 engineering inspections will be required during the course ofthe project: (1) initial stakeout with the contractor to establish the location of the system and to discuss the plans, specifications and construction procedures, (2) after the native material has been excavated to expose the infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test information, (3) after the sewer gravel is in place and the distribution pipes have been laid and connected up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after rough backfill and grading is complete. The septic tank requires one inspection after it is set level and the piping connected, but prior to backfill. This inspection may be incorporated with any of the above inspections. 4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in advance to ensure the availability of the engineer. TI=ST HOLE LEGAL DESCRIPTION: DATE PERFORMED: PERFORMED FOR: DEPTH (feet) 1 2 3- 4- 5- 7 8- 9- 12 13 16 17 18 19 20 COMMENTS: FLATTOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST Lot 7, Block 1, Sky Ranch Estates July 28:1997 Brian and June Kjera SLOPE SM silty sand Pt, SM/ML Very silty sand or sandy silt 0% SP/SM Brawn somewhat silty fine sand Variable Soft digging Cleaner near ctr. portion of stratum Depth to Groundwater Date No groundwater 7/28/97 Monitor tube dry __ 8/4/97 SITE pLAN / #1 LOT 7, BLOCK WHISPERING SPRUCE DR. 2% SM Si[~sand Clock Net Time Percometer Net Drop Date Reading Time (minutes) Reading (inches) 7/28 J_2" Presoak 7/28 Add water & start 2:50 23 3/8 #1 3:00 10 20 11/16 2 11/16 Add water 3:00:30 23 3/0 _ J~2 3:10:30 10 ___ 20 7/8 2 1/2 Add water 3:11 _____ 23 7/16 #3 3:21 10 21 1/6 2 5/16 Add water __3j2j~30 23 9/16 #4 3:31:30 10 21 1/4 2 5/16 PERCOLATION RATE 5 (minutes/inch) PERC HOLE DIAMETER 7" TEST RUN BETVVEEN 10.5 FT AND~,L_L FT Recommend s z ng trench on basis of perc rate of 6 - 15 minutes/inch, i.e. a soil application rate of 0.8 g dp~q/s, ft PERFORMED BY FLA]q'OP TECHNICAL SERVICES. l_ ~"...~ K"~')~,~,-~,L, CERTIFY THAT THIS TESTWAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~,//~ ./~' ~ QGRE[ iR ANCHORAGE AREA BOP' 'IGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME LOCATION MAILING ADDRESS 5,/~/z~ //~-,~- '~/¢27 PHONE LEGAL DESCRIPTION SEPTIC TANK: DISTANCE FROM WELl ~¢~z¢/ INSIDE LENGTH MANUFACTURER _.~77¢ (_/~¢- INSIDE WIDTH NUMBER OF MATERIAL ~("/-/¢'/~'¢-¢4Z2~ COMPARTMENTS-2- LIQUID DEPTH .LIQUID CAPACITY_ / ~-~'~ GALLONS. SEEPAGE PiT: NUMBER OF PITS / DIAMETER -- LINING MATERIAL~--~Q'-( ~ ¢~'~2'CRIB SIZE: BUILDING FOUNDATION ~2 /,>g- NEAREST LOT LINE OR WIDTH DIAMETER LENGTH DEPTH // z DEPTH ~ DISTANCE FROM: WELL TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) . .~ SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE BUILDING FOUNDATION -- CESSPOOL APPROVED CONSTRUCTION NEAREST LOT LINE OTHER SOURCES_ DISAPPROVED NEAREST SEWER LINE REMARKS DEPTH DISTANCE FROM: SEPTIC ~# /~ SEEPAGE TANK SYSTEM / ~'¢ / ¢'" DISTANCES: INSTALLED BY: PIPE MATERIAL: LOT SLOPE: REMARKS: DIAGRAM OF SYSTEM ,4 G.A,A.B. Performed Legal This ~orm "One test is worth a thousm~d opinions" For Glacier Excavating Date Performed Description: Lot .7 Block 1 Subdivision Skyranch Reports Soils Log yes Percolation Test De~th Feet Soil Characteristics Overburden Coarse Silty Gravel GM-22~ 6 m Silty Sand with pockets and gravel 7 _--. sM 25o 10--- 16 ft. bottom of best pit Was Ground Water Encountered? If Yes, At what Depth? of sand No Readin~ Date Gross Time Net Time Depth to H20 Net Drop i' Percolation Rate Minute Proposed Installation: Seeoa~e Pit yes Drain Field Deoth of Inlet Deoth To Bottom Of,Pit Or Trench COMMENTS: .2~0 sq.. I't. drainage area required per bedroom no bedrock 'or water table ~ ft. below £ntended seepage pit ~est Performed By Jim Mack Data .Certified By:Construction Testlab Date: 4-22-7~