Loading...
HomeMy WebLinkAboutSKY RANCH ESTATES #2 BLK 2 LT 15 Onsite File Sky Ranch Estates # 2 Block 2 Lot 15 #015 - 302 - 39 1974 crib can only be adequacy tested for a maximum 3 bedroom COSA approval (with conventional system) . 'o� MUNICIPALITY OF ANCHORAGE e„r On-Site Water&Wastewater Program m Sc�� r PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone: (907)343-7904 Fax: (907)343-7997 y � http://www.muni.org/onsite w 1)r•partrnent 4h�MOR P. On-Site Wastewater Disposal System Permit Permit Number: OSP171311 Effective Date: 10/20/2017 Work Type: Septic Upgrade Expiration Date: 10/20/2018 Tax Code Number: 01530239000 Site Legal Address: SKY RANCH ESTATES#2 BLK 2 LT 15 G:2737 Site Mailing Address: 11711 PINTO CIR, Anchorage Owner: CARPENTER GREGORY S & Lot Size in Sq Ft: 18352 Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 4 This permit is for the construction of: Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing f I / Received By: + Date: 1 v c Issued By: � CJ CO Date: 10 ,2 ' 10/ 7 MUNICIPALITY OF ANCHORAGE 0-1 i Community Development Department Pho, •9�04,0 Development Services Division - 'a : 9 97�� On-Site Water& Wastewater Program T: 0 C T 1 0 2011 ON-SITE SEWER/WELL PERMIT APPLICATION t- 1 • Parcel I.D. 015-302-39 Property owner(s) Gregory & Jennifer Carpenter Day phone Mailing address 11711 Pinto Circle, Anchorage, AK 99516 Site address 11711 Pinto Circle Legal description (Sub'd., Block & Lot) Sky Ranch Estates #2, Block 2, Lot 15 Legal description (Township, Range & Section) Lot Size 18,352 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field ❑x Initial ❑ Single Family (SF) El (w/wo ADU) Septic Tank Upgrade Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage (l THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. I -- (Signature of property owner or authorized agent) Permit/Rush Fees: �i/g Waiver Fees: Date of Payment: /CPPD!/1 Date of Payment: Receipt Number: 0113227 Receipt Number: Permit No. CSP 431/ Waiver No. Permit App_ : ..c Pannone Engineering Services ac Steven R. Pannone, Principal Registered Professional Engineer E-mail:steve@panengak.com October 9, 2017 Subject: Sky Ranch Estates #2, Block 2, Lot 15 Upgrade Septic System Permit Request Design Narrative This is a design narrative for a permit to install an upgrade septic system to be issued for this property. The proposed system will serve an existing three (3) bedroom house, with a four (4) bedroom septic system to accommodate possible future expansion. The existing drain field is in failure and will be re-used as a reserve based on CAT Ill. The system will utilize a replacement 1250g septic tank and conventional drain field. This lot and the surrounding lots are served by a community well.. There are no wells within 200' of the proposed septic system. 1. Soils. One test hole was performed in the vicinity of this system by PES in October 2017, and groundwater was monitored for at least seven days. Ground water was not observed to a depth of 19' below the surface in the test hole monitor tube in October of 2017. Bedrock was not encountered in the test hole to 19'. Based on the results of the percolation tests and overall soils appearance; an application rate of .08 gallons/day/square was used for a conventional wastewater system in the area of the test hole. 2. Soil Absorption System Design. a. See Sheet 1 of the design package. 3. Surface Water: There is no surface water within 100 feet of the proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The existing topography on the lot generally slopes from approximately east to west, with a slope of approximately 12% in the area of the drain field. There are no steep slopes in the vicinity of this system. The proposed drain field will maintain 50' separation all steep slopes. 5. Drawing Markings: The Drawings are marked "For MoA Review Only". When written notification that the review is complete and that there are no further comments is received from MoA On-Site Department, the note will be removed and "Issued for Construction" drawings will be issued. The proposed installation will not affect the future development of this or the surrounding lots. Mailing: P.O. Box 100217, Anchorage, AK 99510-0217 Physical: 332 East Manor, Anchorage, AK 99501 Telephone: (907) 272-8218 FAX: (907) 272-8211 I PTI AR J SE C EA (E) VAII -2 16 ".."'\ 17 z - 5 W / 110.0 W___----/ I A• • I ' LOT 15 S OUSL ‘----" w_ vV OUSL v..., . (F) 10009 SEPTIC TANK (E) 0 2'� DECOMMISSION PER CODE INSTALL 1250g SEPTIC TANK (P) '` ����C�P/ 16.0 INSTALL FCO BEFORE, DCO AND DV AFTER 0 • o 1 CO 0 coa 7CRIB DRAIN FIELD (E) 11.0 RE-USE AS RESERVE BASED ON CAT III 4 - NOT ELIGIBLE FOR COSA — ' BASED ON CONVENTIONAL • • TH-1 \ UPGRADE DRAIN FIELD (P) i 5OLF x 2.55'W x 8.0'ED x 13.0'TD INSTALL CLEAN OUT AND MONITOR TUBE AT EACH ND— W-1 4 1 SEPTIC AREA (E) 13 / ,. / LEGEND / W WATER LINE/ WELL RADIUS SS NEW SEPTIC NOTES: PANNONE ENG SVC, LLC _ QF AL ,4 Date FOR CONSTRUCTION 4 �I, 10/19/2017 P.O. BOX 100217 ANCHORAGE, AK 99510 ...,"""law.• S PHONE (907) 272-8218 FAX (907) 272-8211 ig). •'• �4 9 lf, Scale 50 -�*: , • TK I-\ - * ji ..... .,f.4.. 01 P.I.D. NO SKY RANCH ESTATES #2, BLOCK 2, LOT 15 % .: - • '� 015-302-39 bteven'-:.15•nnorae PERMIT NO. GREGORY AND JENIFER CARPENTER /+ * CE 8149 ' �� OSP171311 11711 PINTO CIRCLE i _ PLAN ANCHORAGE, AK 99516 �l�kU14-;,' Oi-ES.900\"` Sh1e0f 3 \\�� SOILS LOG - PERCOLATION TEST TEST HOLE 1 SLOPE -.I4 • ..517E PLAN OR ORGANICS ' G� 1 W 2 -4" . i' LOT 15 y 3 \ir\_\ 4 w w------ ::::‘ • 5 ' 1 6 X \ . TH • 7 -D / • # g 0 GM/ SILTY GRAVEL C? ` A s r • 1 SM AND SAND ill 10 - 11 " ) TH-1 1 12 13 WAS GROUND WATER SLOPE 14 ENCOUNTERED? N 15 IF YES,AT WHAT TH DEPTH? -DRY 16 X 17 DEPTH TO WATER AFTER MONITORING? -DRY 18 DATE: 10/9/17 WATER 19 BOH READING DATE CLOCK NET TIME LEVEL NET DROP READING DATE PERFORMED:10/03/17 1 10/03/17 3:10 --- 5.41 -- 2 3:20 10 MIN 8.31 2.90 3 3:20 --- 5.41 -- 4 3:30 10 MIN 7.65 2.24 5 3:30 --- 5.41 -- 6 3:40 10 MIN 7.53 2.12 7 3:40 --- 5.41 -- 6 3:50 10 MIN 7.49 2.08 PEROLATION RATE 4.8(min/inch)PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 4 FT AND 5 FT COMMENTS:Test hole excavated by A+ HOME SERVICES PERFORMED BY: Dan Moran. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDLINES IN EFFECT ON THE DATE OF THIS TEST. NOTES: PANNONE ENG SVC, LLC -,,,,,-........,u,` Dote FOR CONSTRUCTION .q ll� 10/19/2017 P.O. BOX 102954 ANCHORAGE, AK 99510 �,`, • s� Scale PHONE (907) 272-8218 FAX (907) 272-8211 ig.• �4� .•y f*: 49TH /\ � N TS fri..... •' 0 P.I.D. NO SKY RANCH ESTATES #2, BLOCK 2, LOT 1§---6 ..... .11116 / 015-302-39 GREGORY AND JENIFER CARPENTER Steven f�. 'annorae PERMIT NO. 6 ��•, CE 8149 • / OSP171311 11711 PINTO CIRCLE T# k` '.. .-r:i SOILS LOG ANCHORAGE, AK 99516 lij���?OFESSIONP�-�`_ Sheet 1���x"��' 20F3 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON-SITE WASTEWATER DISPOSAL SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55. 2. SCOPE OF WORK: INSTALL NEW SEPTIC TANK AND SOIL ABSORPTION SYSTEM. 3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 19 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 19 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. 4. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) SHALL HAVE ANY WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK. 5. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS. OTHER THAN THE ATTACHED. 6. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES. 7, THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES SHALL BE IN PLACE PRIOR TO NOTIFYING THE ENGINEER. 8. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SIT CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN. 9. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED-LINE AS-BUILT DRAWINGS TO THE ENGINEER. THE RED-LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS. AND TANK ELEVATIONS. 10. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN-OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING. 11. THE CONTRACTOR PROVIDED DATA (UPON WHICH THIS RECORD DRAWING IS BASED) APPEARS TO REPRESENT THE PROJECT AS CONSTRUCTED. THIS DATA IN CONJUNCTION WITH THE PERIODIC FIELD OBSERVATIONS BY THE ENGINEER (OR HIS DESIGNEE) AS REQUIRED BY AMC 15.65 DOES NOT GUARANTEE THAT THERE ARE NO HIDDEN DEFECTS BY THE CONTRACTOR. 12. THE CONTRACTOR SHALL SIGN THE FOLLOWING: I CERTIFY THAT ALL WORK WAS PERFORMED IN ACCORDANCE WITH THE APPEND PERMIT, AND ANY AND ALL CHANGE ORDERS, AND THAT THE AS-BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED. CONTRACTOR: BY: . TITLE: • ABBREVIATIONS DATE: CU COPPER DESIGN PARAMETERS MIN MINIMUM TH TEST HOLE RESERVE SEPTIC SYSTEM FC FOUNDATION CLEAN OUT DESIGN PARAMETERS NO. BEDROOM: 4 (600 gpd) T# TANK CLEAN OUT NO. PRIMARY SEPTIC SYSTEM TANK SIZE: 1500g ADVANTEX C# CLEAN OUT N0. NO. BEDROOM: 4 (600 gpd) W/ AX20 POD M TANK SIZE: 1250g PERC RATE: 16-30 MPI M#. BE NO. RIGID INSULATIONNITOR TU PERC RATE: 4.8 MPI SOIL RATING: 4 GPD/SF SOIL RATING: 0.8 GPD/SF AREA RQD: 150 SF DCO DOUBLE CLEAN OUT AREA RQD: 750 SF SYS. TYPE: CRIB 7'ED DV DIVERTER VALVE SYS. TYPE: DEEP TRENCH 8.0'ED LENGTH: 29 LF FS FLOW SPLITTER MIN LENGTH: 46.9 LF WIDTH: 22 LF BFG BELOW FINISH GRADE OG ORIGINAL GRADE USE: USE: FG FINISH GRADE 50 LFx2.5'Wx8.0' E.D., 13.0' TD CRIB 29 LFx22'Wx7.0' E.D., 12-13' TD TS&V TOPSOIL AND VEGETATE TOTAL AREA: 800 SF TOTAL AREA: 714 SF NIC NOT IN CONTRACT NOTES: Date PANNONE ENG SVC, LLC OF AC FOR CONSTRUCTION P.O. BOX 100217 ANCHORAGE, AK 99510 :4 � 0/19/2017 + 1 PHONE (907) 272-8218 FAX (907) 272-8211 '�.!j scale le 40 . o P.I.D. NO SKY RANCH ESTATES #2, BLOCK 2, [01-4-5- :, - e 015-302-39 GREGORY AND JENIFER CARPENTER � � 'teven �annome je PERMIT NO. � CE 8149 . 11711 PINTO CIRCLE �+ .s,• OSP171311 �� DESIGN DETAILS ANCHORAGE, AK 99516 lHgpFE5S10Na��s Sheet t\\N.XW>"- 3 OF 3 QGRE' Ell ANCHORAGE AREA B()r 'UGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME ~0. ,L/¢9 ¢,~ LOC AT I O N O/=~/; ~'/~ ~ ti MAILING ADDRESS ~*/~/) /~-¢z( l/z~2-~/ PHONE LEGAL DESCRIPTION /-g~r' /.3~/ SEPTIC TANK: DISTANCE FROM WeLL INSIDE LENGTH MANUFACTURER MATERIAL NUMBER OF COMPARTMENTS _ INSIDE WIDTH LIQUID DEPTH __LIQUID CAPACITY /Z~¢() GALLONS· SEEPAGE Pit: 2~/ 1.2/-/5 / NUMBER OF PITS / DIAMETER OR WIDTH LENGTH 2-¢, / __ ~ , DEPTN LINING MATERIAL /¢~,.r.~ ,¢~,¢,~/, CRIB SIZE: DIAMETER___DEPTH DISTANCE FROM: WELL BUILDING FOUNDATION '~¢2 //~ NEAREST LOT LINE ~z~*¢ //- TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) '~//¢' S(~. FT. ADDITIONAL ABSORPTION WELL: TYPE ~ m ~"R~¢~ CONSTRUCTION BUILDING NEAREST FOUNDATION __ LOT LINE CESSPOOL OTHER SOURCES__ APPROVED DISAPPROVED NEAREST SEWER LINE REMARKS DEPTH DISTANCE FROM: SEPTIC SEEPAGE TANK SYSTEM DISTANCES; DIAGP, AM OF SYSTEM INSTALLED BY: ~'~/'Z~I£/ET.~ ~-/~4 PIPE MATERIAL: LOT SLOPE: REMARKS: Form NO. EQ-031 DATE APPROVED~C~¢~,c_,t~¢ ~'. E~,/%/~ G.A.A.B, GrEAT!=r ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-456! SEWAGE DISPOSAL SYSI"EM -- APPLICATION AND PERMIT NAME Of APPLICANT ;/'YgCO('~/' INSTALLATION LOCATION LEGAL DESCRIPTION INSTALLATION Of: SEPTIC TANK PERMIT NO. r~ ~DR AI N FIELD OTHER TYPE AND SIZE OF FACILITY TO SE SERVED ~2~ ~,¢' L NOTE= TFII8 PERMIT IS NOT VALID WITHOUT 8OIL TEST COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL iNSPECTION BY THE DEPARTMI'"NT OF ENVIRONMENTAL. QUALITY AUTHORITY Will BE SUBJECT TO PROSECUTION. TYPE FOUNDATION TO SEEPAGE PIT ~' ~'~ ( .. DRAIN FIELD - / SEPTIC TANK TO SEEPAGE PIT WALL /] ~m WELL TO SEPTIC TANK. C-~'~'~'~'~"E~P~E, P~IT~'~ DIAGRAM OF ~Y~TEM WATER MAIN TO SEPTIC TANK DRAIN F]ELD SEPTIC TANK, ~r , SEEPAGE PIT TO rIVER, LAKE. STREAM. ., SEEPAGE PIT ./0~//) , DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION S FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAS]' IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION, LICENSED DESIGNER GREATER AN(:: ORAGE AREA BOROUGH ORDI NCE NO. DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID (;ODE. DATE -- 'l-- / -/- APPLICANT'S S'C.^TURE AND THAT THE ABOVE Performed For G].aoier Excavating Lenal Oescriotion: Lot1~ Block2 This ~orm Reoorts Soils Loq yes "One tes~ is ~uorlh a :housa,M op'~ 'o, s ' Date Performed 6-1~4 .... Subdivision Skim~noh Percolation Test__ Oe~th Feet Soil Characteristics 2-- 3-- 4-- 5-- 6-- Silty Sand SM-.2~0 Thruout Depth of Tost Hole Bottom of Test Pit -16 ft. Was ~round Water Encountered? No I¢ Yes, At what Depth? Readinq Date Gross Time Net Time Depth to H20 Percolation Rate ~linute Proposed Installation: Seepaae Pit yes Drain Field Deoth of Inlet Depth To Bottom Of Pit Or Trench. Net Drop CO~!'ENTS:__2~9 ,~. ft..drainage area~oj~irea No bedrock or water table Oonst. Test Lab Data Certified B~: Test Performed By. Jim Mack ...... Lab Manage~' Date: 6-1 ~-~]~