HomeMy WebLinkAboutSKY RANCH ESTATES #2 BLK 2 LT 22 Municipality of Anchorage page _J__ o~ DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 345-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: .__5.W c~ 30 I'/L~ ........ PID Number: Ol,53°2L/~ Name: Wastewater System: [] New 1~ Upgrade JEFF + KRIS'FIN ~o6N£5 Address: 11"711 Sh~ET£ANb HT$ CI~,, ~c~ 9~-,6 ABSORPTION FIELD I No ol .~drooms ~f Deep Trench I~ Shallow Trench [3 Bed E] Mound O Other 0,~O GPD/Sq Ft 10,~' ! "°' 22. 2 Township:l: N I rian[,e%i s.o,io,,I Fill addnd above original grade: Grave, length: ~ 2~ 0.~ ~, ~' ~1~' '- ~ Ft. Number o~ lines: ~ Oisiance between lines: SEPARATION DISTANCES ~Seplic O Holding 0 S.T.E.P. From Tank Fmeld Slalmor, Tank Sewer Lmnes We, ~ - - ~ -- Co~cRg'r~ Water ~/~' >~oo ~ - '>~o~' LIFT STATION ~,A, L Remarks: ~¢ph~ t~n~ ~z ~,~ ~'~ BENCH MARK I~0~+ ~llon, ~ con,~a~t~tn~ m~cre~ ~nl¢ LccationandDescription: Inspections performed by: ~LA~oP }gE'l¢ 5F6g Dates' 1st Department of He nd Hum endces appro~al/ Reviewed and app 72-013 {Rev. 9'91} MOA 25 PermitNo._ .~I,v c~'801'7fit Page 2. of ~ Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVlRONMEN'DAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: .LOT 2'2, I~LK .2. , ¢&-¥/~/]NCff EST, t~2. PID No.: TRENCN 3 BDRM HOUSE C.O, "b 'T' I E_~ :~oM A I5 ~L' go' 72-013 A {Rev 9/91) MOA 25 Flattop Technical 14530 Echo Street /t.nchorage, Alaska 99511 Permit No. ~ ~j~.~_O~!__-7 ~ __ Page Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: ~,¢T 2~,~tl< '2, SKY~,~NC// EST,'~t'2 PIDNo.: Ol SEPrrc_____'[ANIC J) VERTICAL SCALE: / =S l~o doRIzo,',{T4c SCALE FoR L/IY OU'F Flattop Technical Services 14530 Echo Sh'eet Anchorage, 2-[laslcc~ 99516 CONC. SLAB ELEV ; I00,o t ..~ r ~o~%O~ oF TRENC~ T. 14. Cz 72-013 A (Rev 9/91) MOA 25 PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW930174 DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES OWNER NAME:ROGNES JEFF R & KRISTIN A OWNER ADDRESS:il711 SHETLAND HTS CIR ANCHORAGE, ALASKA 99516 PARCEL ID:01530246 DATE ISSUED: 6/22/93 EXPIRATION DATE: 6/22/94 LEGAL DESCRIPTION: SKY RANCH ESTATES #2 BLK 2 L T 22 LOT SIZE: 15801 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE: ATTACHED APPROVED DESIGN. 2. ALI, REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AACS0). 3. THE: ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CAI, LING 343-4329 OR 343-4681 AFTER BUSINESS HOURS 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: C 0~/. DATE: CIVIL & ENVIRONMENTAL ENGINEERING · ENERGY CONSERVATION & ANALYSIS TIfEODORE F. MOORE, P.E. June ~.~A, 1993 14530 ECHO ST. PH: (90?) 345-1355 ANCHORAGE, ALASKA 99516 M.O.A. DHHS P.O. Box 19-6650 Anchorage, AK 99519 Dear Sh's: The purpose of this letter is to provide the requh'ed design nan'ative ill support of our application for a permit to upgrade the wastewater disposal facilities on Lot 22, Block 2, Sky Ranch Estates #2, located at 11721 Shetland Heights Cimle. While it is not backing up, the existing soil absorption system was found to be operating in a surchm'ged condition, and thus cannot qualify for a HAA certificate until it is upgraded. Soils logs, perc test results, a site plan, design drawings and specifications m'e enclosed for your review. The proposed system will be constructed between test holes #1 and #2. As can be seen from the soil logs, the native material between between 3.5 and 16.5 feet below ground level is a gray sandy silt with a measured perc rate of 10 minutes per inch. Using a slightly conservative soil application rate of 0.6 gpd/ square foot, specified in the wastewater ordinance for soils with perc rates between 15 and 30 minutes per inch, this 3 bedroom residence requh'es a total absorption m'ea of (3 x 150)/0.6 = 750 squm'e feet. Tile proposed 73 foot long trench with 6 feet of sewer gravel beneath the horizontal distribution pipe has a total effective absorption area of 756 square feet. Ten feet of trench length, where it passes through the vicinity of the old septic tank, have not been counted in the calculation of effective absorption area. The topography of the lot in tile vicinity of the proposed construction is generally level, with a slight slope down towards the west. The proposed project will have no known impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any impact on reserved space/surface and subsurface, or on di'ainage. Please give me a call at 345-1355 if you have any questions on this submittal. Sincerely, Ted Moore, P.E. SoT 2 ~ 15" ,,~ / ~I HoLE LoT 22 Flatto~ Technical Semites 14530 Echo Street Anchorage, Alaska 995] LOT 22., BLK 2, SKYRANCH .~ITE PLAN SCALE'. 1"=3o' DATE: D~,~ BY.' NOT~.. TH~s 15 NOT ~LL LocAT{o~I ~ ,~1~.~ AP?Rox Ir'lATE , NEw IooO 6AL PLAN VIEW 1'= 10t S[CT ~oN "A -A" 1"= 5~ / Hoi41TOf- TuBE ' 2~ 10.5t EXCAVATION ~]at[0'~ Te'ch~ica] Se~ices 14530 Echo Street Anchoraqe, Alaska 99516 LOT 9.2, BLk 2, 5KYRAt~C~t ~2 50IL ABSORPTION-FRENCH PLAN, 4- CROSS SEC_'FIoN SCALE Flattop Technical Services 14530 Echo Street, Anchorage, AK99516 Phone (907) 345-1355 Lot 22, Block 2, Sky Ranch Estates #2 11721 Shetland Heights Circle Wastewater disposal system installation Specifications 1.0 General: 1.1 The scope of the project consists of abandonment of an existing 1250 gallon septic tank and installing a new 1000 gallon septic tank followed by 73 lineal feet of soil absorption trench containing a toted of 6.5 feet of sewer gravel. 1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor deviations from these drawings may be allowed or required by the engineer condacting the inspections. All construction procedm'es and material specifications shall conform with Municipal and State requh'ernents. All separation distances shall be in conformance with Municipal requirements, unless specifically waived. 1.3 The conU'actor shall be responsible to obtain any necessary utility locates, and to work around any bm'led utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensm'e that proper drainage is achieved after settlement and that there are no residual depressions. Insofm' as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the construction. 2.0 Septic Tank: 2.1 The existing septic tank is to be properly abandoned by thoroughly pumping, removing, crushing and bm3'ing on site, or by another approved method. 2.2 The new 1000 gallon septic tank shall be Municipally approved, and shall be set level on undisturbed soil.. Each compartment shall be equipped with a watelXight manhole cover and a 4" cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial type, rigid insulation. 2.3 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The waste line from the residence to the septic tank shall have a minimum slope of 1/4"' per foot, and the waste line between the tat~k and the soil absorption system shall have a minimum slope of 1/8" per foot. A double cleanout shall be installed within 5 feet downstream of the septic tank. 3.0 Soil absorption system: 3.1 The soil absorption system shall be constructed by excavating a 73 foot long U'ench to a total depth of 10.5 feet below the present ground elevation in the vicinity of test hole #2. 3.2 The bottom of the wench excavation shall be level. Any compacted or smeared sidewall surfaces shall be raked to allow proper infilu'ation. 3.3 A total of 6.5 feet of approved sewer gravel shall be placed in the bottom of the excavation with the perforated distribution pipes laid level such that the pipe inverts we no less than 6 feet above the bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing the g200 sieve. 3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on the design drawings. The portion of the monitor tube extending through the sewer gravel shall be perforated. 3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gl'avel before backfill with clean soil. 3.6 The top surface of the cover material shall be raised a minimum of 6 inches higher than the surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill slopes shall be no steeper than 3:1. 3.7 After the baclffill material has stabilized, all m'eas distm'bed by the construction shall be covered with 4 inches of topsoil and seeded with grass to promote rapid revegetation. This work shall be the responsibility of the property owner, unless specific m'rangements m'e made with the septic system installer. 4.0 Inspections: 4.1 A total of 4 engineering inspections will be required during the course of the project: (1) initial stakeout with the contractor to establish the location of the system mid to discuss the plans, specifications and construction procedures, (2) after the native material has been excavated to expose the infila'ative surface to ensure that it is level and at the right elevation, and conforms with the soil test information, (3) after the sewer gravel is in place and the disu~ibution pipes have been laid and connected up to the septic tank, but prior to placement of filter fabric, and (4) after final backfill and grading is complete. The septic tank requh'es one inspection after it is set level and the piping connected, but prior to backfill. This inspection may be incorporated with any of the above inspections. 4.2 The inst~ller shall coordinate the timing of the inspections with the engineer sufficiently far in advance to ensm'e the availability of the engineer. .ERFORMeD F F ~'l~tfS]~ T~'~fi~! Services ~ - 14530 Echo Street Anchoraqe tUc:~!,'a 995!$ Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST ROGNES LEGAL DESCR PT ON LoT 2'~. ~LK 2 ~L FILL 2 PT 3 ,~h~ REbblS~/ 7- 8- 9- 10- 11 12 13 14 15 16 18 19 20 COMMENTS t4'2'T°wnship'sLopERange' Section: SAC. S~i2Tt~ PLAN SANDY Lo~M SoM~ COBBLES 4 GRAVEL ~fo "7 ~OCKE TS OF F~NE ,~ND WAS GROUND WATER ENCOUNTER ED? S IF YES, AT WHA'r DEPTH? I} Oeplh [o Waler Alle~ Reading Date Gross Net Oopth to Net Time Time Water Drop i~-~PRESo/~, s~/~o[~- Io:~o~.oc~ :2'/ 10WB',°° .... [Ko3:oo 15 2t Y~ ) Y~ *H~O H:o3: 3o 23 ~.H20 Il:lq:°° ~S ~ ft~;o 11,3~,~' ' o 23 ~, PERCOLATIONRAIE _/O (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~ FY AND ~,-.~ FT CERIlFY THAT THIS TeST WAS PERFORMED iN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev 4/85) FERPORMED POR:__2E FF ~.d'tt6~5 T685~E~I Services ,~. .... 14530 Echo Street .Anchoraffe, Alc::',l,'.q 995!8 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST RoGN~, LEGAL DESCRIPTION: LoT 2'~, ~LK 2 pT ~L FILL ~f~ R£DDIS~ 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 5k~l~/l~Cl'l ¢2T°wnship, Range, Section: $E¢ ~'2,, 5jNb¥ ADA,'4 ff.,Il, ~l BUT L£~¢ ANb ~ORE 5/}Nb COMMENTS CoME CoBBLE~ ANb 'FO ~ ' SLORE WAS GROUND WATER ENCOUNTERED? S IF YES, A'F WHA F DEPTH? ~,/~ O E Deplh Io Water Aller I(~, ~.G,L, SITE PLAN Gross Net Depth to Net F~eading Dale Time Time Water Drop PERCOLATION RATE }EST RUN BETWEEN (minutes/inch) PERC HOLE DIAMETER . F'[ AND FT ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFEC] ON ]'HIS DATE· 72-008 (Rev. 4/85) CER]IFY THAT THIS TEST WAS PERFORMED IN DATE: GREA1ER ANCHORAGE AREA BORg GH Department of Environmeni~al Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATION MAlt. lNG ADDRESS .%i~,/~ t~'~,"~-~" I'~ PHONE LEGAl_ DESCRIPTION ~'~ SFPTIC TANK: DISTANCE (~l FROM WELL"~¢) } INSIDE LENGTH MANUFACTURER NUMBER OF COMPARTMENTS INSIDE WIDTH LIQUID DEPTFI__ __LIQUID CAPACITY_® GALLONS. NUMBER OF PITS --- LINING MATERIAL BUILDING FOUNDATION__ ADDITIONAL ABSORPTION DIAMETER OR WIDTH CRIB SIZE: DIAMETER NEAREST LOT LINE , LENGTH____, DEPTH DEPTH .... DISTANCE FROM: WELL TOTAL EFFECTIVE ; ABSORPTION AREA (WALL AREA) ~1'$~ ~" SQ. FT. WELL: TYPE ~'~-F~ff~ tl~.. BUILDING FOUNDATION CESSPOOL _ APPROVED __ DISAPPROVED _ CONSTRUCTION NEAREST LOT LINE OTHER SOURCES ..... DEPTH NEAREST SEPTIC SEWER LINE TANK REMARKS ..... DISTANCE FROM: SEEPAGE SYSTEM DISTANCES: INSTALLED BY: LO(.~'(~- _~_~/~ (_. LOT SLOPF REMARKS: -- Form No, EQ-031 DIAGRAM OF SYSTEM APPROVED G.A.A.B. 25J~0 E. DE:F'Fh~:Tf,IEN'I" : HERL.'I"N RN[:, Ef.,l',,: I RONHENTf:IL ,' -'l"[:J- T"~ N , UDOR RE:,. · FINC:NOF,'.f:I[~iE., PERMIT NO. ( 7~;;T'.~,¢, ) SRR :t.6 :'.'::5 [:, E, LI',. 2 =,K-r RRNr_':N ES'f'RTES FIF'F:'L I CRNT NEI. [:,RE'¢HRi"I~ LOCFITION =,HEY~LCff., HEIGHT.:. CIR...LE L.E(IFIL LOT .., I ~E T'T'F'E OF SOIL F:IBSORBTION SYSTEM I.=,. TRENCN ' ,' I 4 HR,,,Ii'ILM F,IIJHBE'R OF E:EDROOHS = (=:,U FT,"BR ) =' :1 .... SOIL RAI'INI3 ,-"l · o= THE REQLIIRED SIZE OF THE .~IJIL I--IB~ORFIlOrl .=,T~TE.M THE LENGTH DIMENSION IS THE LENOTFI (:IN FEET) OF THE TRENCH OR I)t;.:RINF'IISI._D. THE DEPTH OF R TRENCH OR PIT IS THE DI~;"FFINCE BET;,.IEEN THE SURFRCE OF THE GROUND FIND THE BOTTOM OF THE EXCRVRTION',:.'IN FEET>. 'THERE IS NO SET WIDTH FOR 'FRENCHES. TNE GRRVEL DEPTH IS THE MINIMUM DEPTH 01:' EiRRVEL BETNEEN THE o(.rTFRLI.. P;rF'E: AND THE E:OTTOH OF THE EXC:RVRTION (IN FEIET). EITHER FI C.[_Rz~_ I OR II NSP ,~PF'ROVED PLF1NT I"IFPr' E:E IN.::,IPLLE.L.. R C:ONTINUOUS MRINTENRNCE RGREEMENT IS F.:EQtJIF,:ED. IF' R MRIhI'FENRNCE - ~.. ~ .,. ;,., - ::,. I L. t.~REEMEf',IT I:, NOT KEPT :':LRRENT YOU MR'¢ BE F,'EQLIIF,'ED TO ENL. FtF.L~E. TFIE ' ' '"' .":' ' , , "r'OU .'5,1JELTEIZ T T(:I PR.: 5ECI.JT 1 ON. FIE:SORPTION mN_,3'EM FIND/OR r,lR'.¢ BE IF' FI CLRSS'; I S'YSTEM IS LSED THE LENGTH IS 4.,':i-. 0 FEET. _.LA__ II SN.'STEM IS U_.ED THE LENGTH IS ...6. O FEET, q ,,~ , '- ' ' rlI.L EIRC:I<FILLING OF RNY _'T~TEi'I ;,JlTHOtJT FINRL II'.,I.=,PE...I'ION AND FIPPI;.:OVFII_ E:"r' "" '::' [:,EF'RWFMENT !.,.IILL BE _,UE, JEL. T TO PROSE::LFrION. HINIIqLIr,'I DISTRNC:E EETNE. EN R WELL Rf'4[.~ RN'T' ON-SITE =,EIIR.*E. !:':,IqF'F':;Pll : 'r_TEll ) :1. OO FEET Fr:IR Fl PRIVRTb: WELl- OP, ;'~OO FEET FOF-: FI F'UBI_IC WELl.., ...., ........ f-, ~ >f-EL. IF I-.RTIONz RND CONSTRUCTION [:,IRGRRr,'IS FIRE FIVRILFIBLE TO INSUF,'E PR. 3PER ]: I'4.S T'Rt_LRT Z ON. ]: CERTIF"r' THRT d.: I RM FRMILIRR Hl'r'H THE REO. UIREEMENTS FOR ON-SITE SEWERS RND 14ELLS RS SET F;'ORTI-; B'T' THE i"IUNICIPRLIT'T~ OF FINCHORRGE. 2:': I WILL INS'FRLL.. THE SYSTEM IN F:ICCORDRNCE 14ITH TFIE CODES. 2~:: I tJNDERSTRND THRT THE ON-SITE SEWER SN"S'TEM I'"IRY F.:E:C,!tJIRE E:NLRROE.r. MENT IF' TF'IE RESIDENCE IS REMODELED TO INCL. UDE MORE THFIN 4 BEDROOI"IS. RPPLI CRNT NEIL DRIE'¢HFIH MUNICIPALITY OF ANCHORAGE Department of Health and Environmental Protection SOILS LOG PERCOLATION TEST Performed for Neil Dreyham Date Performed 5/18-19/76 Legal Description Lot 22, Block 2, Skyranch Estates Subdivision (See back for hole location) l0 Dark, red-brown, silty, sandy gravel (GM) Perc rate = 225 ft.2/bdrm. Gray-brown, silty, gravelly sand (SP) Perc rate = 150 ft.2/bdrm. Gray~ silty, sandy gravel (GM) Perc rate = 225 ft.2/bdrm. No water table encountered. AVERAGE PERC RATE FROM SOILS LOG = 210 ft.2/bdrm. Date Net Time Depth Net Drop 5/18/76 7 min. 17.5 in. 10.5 in. 12 min. 27.0 in. 20.0 in. 5/18/76 5/29/76 24 min. 35.0 in. 28.0 in. 1229 min. 95.0 in. 83.0 in. · ~/19/76 1331 min. 102.0 in. 95.0 in. Percolation Rate 14 minutes/inch = 185 ft.'~/bdrm. INC. July 22, 1975 R & M NO. 562068 J~c~ Nam~el 5706 East Northern Lights Blvd. Anchorage, Alaska 99501 RE: Test Hole and Soil Log Report for Sanitary System Lot 22, Block 2, Sky Ranch Estates Dear Mr. H~pel: We are submitting herewith the test boring results and our comments regarding soil conditions encountered at the subject site. This investiga%$on was per- formed in accordance with your request of 7-18-75, and those pro6~dures out- lined in a letter dated December 19, 1974 by Mr. Rolf Strickland of the Greater Anchorage Area Borough Department of Environmental Quality. A single test hole was put down within the Lot 22 area for the purpose of defin- ing general subsurface soil conditions for the proposed sanitary system. Ex- cavation was accomplished with a tractor-mounted backhoe and the test hole was extended to a total depth of 14.5 feet below ground surface. The final log prepared for the test hole has been included in Drawing A-01. Ground water was not encountered in the test hole. We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above, please do not hesitate to contact us. Very truly yours, R & M CONSULTANTS, INC. JWR/ja xc: GAAB T.H.-1 7-18--75 ORGANICS ORGANIC SILT 0.0I 3.0I SILT, SOME SAND TI~ACE GRAVEL NO WATER TABLE 14.5' T.D. Log Represents Lot 22 Block 2 Sky Ranch Estates Engineering ~ Geologic(Il Consultants Inc, ANCHORAGE FAIRBANKS ALASKA JU.EAU Jack Hampel Property Log of Test Hole Anchorage, Alaska DATE 7--22--75 ]SCALE 'L"-3' IDWN 8Y WE,D JCHKDOY WED Ip~O4. NO. 562068 IDWG NO. A-01 ANCHORAGE, ALASKA 99501 of (907) 264-4111 l ChOr ¢ EORO. M. EU.L,VAN MAYOR ENV R 0~ ~ ~'~k~ ~ ~,,~ DEPARTMENT OF HEALTH AND DEPT. OF ENV[RONMEN1 AL May 19, 1980 I~/~AY 2 8 1980 RECEIVED Sue Remlee Star Route A Box 1621 Anchorage, Alaska 99507 Subject: Lot 22 Block 2 Sky Ranch Estates Subdivision Approval for your individual sewer and water facilities can not be granted until the following items have been completed: (1) The septic tank pumped with a receipt submitted to this department. If there are any further questions, office at 264-4720. Sincerely ,~ Fo~b~r t~C. Associate Specialist please contact this RCP/ljw CC: Ronald D. Miller % Bowden Co. Realtors 8403 Little Dipper 99504 PENINSULA ENG]INEERING 2820 "C" Street, Suite #3 Anchorage, Alaska 99503 276-4855 !.i: 2 November 15, 1980 Susan Renele Shetland Circle SRA #1621 Anchorage, Alaska Re: Lot 22 Block 2 Skyranch Estates #2 (file #80-E-23) Sewer System Adequacy Test Dear Ms. Renele: As per your request, I have performed an above listed property in accordance with Anchorage guidelines. adequacy test on the the Municipality of The system consists of a septic tank in con~ination with a drainfield and was tested as follows: 1. Water was fed into the absorption system at approximately 10 g.p.m, for a total time of 65 minutes on two consecutive days and the depths in the drainfield and septic tank were monitored at regular intervals. The total volume added to the system was 650 gallons each day. The depths recorded are listed on the attached data sheet. The test results indicate that the system is functioning nor- mally and would, in my opinion, be considered adequate for the existing four bedroom home. Sincerely, Wayne Henderson, P.E. TEST DATA LEGAL DESCRIPTION: Lot 22, B±k 2 Skyranch Est ~2 DATE WATER LEVEL SEPTIC TANK WATER LEVEL DRAINFIELD TIME (MINUTES) il/il/80 11/12/80 52" 0 53" 0 53" 0 53" 0 53" 0 54" 0 54" 0 54" 0 54" 0 54" 0 54" 0 54" 0 54" 0 54" 0 54" 0 54" 0 54" 0 54" 0 0 (9:00 5 10 15 20 25 35 45 55 65 0 (9:00 10 20 30 4O 5O 60 65 am) am) MUNICIPALITY OF ANCHORAGE Development Services Department OnSite-Water-& Was e��Section - -- - - Parcel I.D. 015-302-46 Certificate of On -Site Systems Approval Expiration Date: Legal description SKY RANCH ESTATES #2 BLK 2 LT 22 Site address 11721 SHETLAND HEIGHTS Current property owner(s) Jeff and Kris Rognes Phone: 907-343-7904 X The On-site system(s) is/are approved for Y bedrooms Conditional approval for bedrooms, with the following stipulations: rax: UU1- 1-343 -- Comments or advisories: Buyer is to be aware that there is a belly in the sewer line upstream of the septic tank. Periodically this line clogs and is required �0z to be jetted/snaked every few years. This is not a code violation so is not required to be repaired in order to obtain a COSA. Original Certificate Date: 4/3/2023 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA ApprovMjune 2022 t MNPA1" OF ANCHORAGE Development Ser --ices Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 .Ge rtificate-of O-n=Sjte-Systems Approval Application - 1. GENERAL INFORMATION Parcel I.D. 015-302-46 Complete legal description SKY RANCH ESTATES 42; BLOCK 2, LOT 22 Location (site address) 11721 Shetland Heights Circle *Anchorage Current property owner(s) Jeff & Kris Rog nes Day phone 441-8043 2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: ❑ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑■ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: FN� Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel ❑ Plastic [N—J Concrete ❑ Fiberglass Age 50 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed 0 Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee Waiver Fee $ Date of Payment 3 ,/Z 7/3013 Date of Payment COSA # 05C 2 2 1 or,_63- Waiver # COSA Applicabon June 2022 rin% COSA Checklist Legal Description: SKY RANCH ESTATES #2; BLOCK 2, LOT 22 Parcel ID: 015-302-46 30g4 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system A. WELL DATA COMMUNITY WATER SYSTEM ❑ Well log is filed with Onsite (or attached) Well production at time of test Date drilled Total depth ft Water storage tank vol u gallons Cased to ft Well disinfec or coliform test? ❑ Yes ❑ No ❑ Sanitary seal is functioning correctlyE:I- Ariform bacteria is Negative ❑ Wires are properly protected Nitrate mg/L ❑ Nitrate less than MRL (ND) Casing height (above ground) Arsenic u /L g ❑ Arsenic less than MRL (ND) Date of flow test for COSA Collected by Static water lev eginning of test ft. Date B. TANK DATA Measured operating fluid level in septic tank Date of pumping 3/17/2023 ❑ Required maintenance completed, if AWWTS Comments: SEE ATTACHED EMAIL FROM ARM REGARDING TANK BAFFLE C. LIFT STATION ❑ Required maintenance com Age of lift station years Lift statin erial DATA IS FOR 1976 TRENCH D. ABSORPTION FIELD DATA Which system tested (date installed) 1976 Adequacy test date 3/13/23 ❑ ALL standpipes present per record drawing Results 0 Pass 9.66 Total measured depth from grade (max) ft Fluid depth prior to test 15 Measured depth to pipe invert from grade 5.0 ft (min) Water added 683 gal ❑ N/A — pressurized field. New fluid depth 32 in ❑ Per record drawings, field is insulated. Elapsed time 130 min ❑ Monitor tubes go to bottom of effective. Final fluid depth 26 i,n If not, state depth into effective EAST: 4.5'-4.7' WEST: 4.08' 4.25' Absorption rate 600 9pd in � 323 �l t 2 ❑ Presoaked required If FIELD STATUS�'c OST RE OVERY (Required if house vacant or field not us r more Effective depthr re, drawings) 72 in than 30 days prior to date of test Gallons introduced gallons date Effective depth used it Effective depth emainin a ' Any rejuvenrment ( eatpast 12 months) enter date D In Comments/Deficiencies: TESTED 1976 TRENCH ONLY - EAST TRENCH IN 1993 SYSTEM WAS DRY DURING GEG INSPECTION SEE ATTACHED EMAIL FROM ARM SEPTIC SERVICES AND OWNER REGARDING THE OUTLET BUNG AND SEWER LINE PRIOR TO TANK. ADDITIONALLY, SEE ATTACHED LETTER FROM GEG REGARDING BUNG AND SEWER LINE COSA Checklist—June 2022 9%V1 if E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanou _ ❑Yes if No ft Yes if No Neighboring Tank > 100' ❑ Yes if No ft Private Sewe is Line > 25' [:]Yes if No Absorption Field on Lot > 100' ❑ Yes if No ft ding Tank > 100' ❑ Yes if No Neighboring Absorption Fields > 100' Animal Containment > 50' E] Yes if No ❑ Y I No ft Manure/Animal Excreta Storage > 100' CommunitySewer M _ 5' ❑ Yes if No ft ❑ Yes if No ❑ N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No *5+ ft Surface Water > 100' ❑ Yes if No Tank to Property Line > 5' ❑■ Yes Field to Property Line > 10' ❑■ Yes Water Main > 10' ❑■ Yes Water Service Line > 10' Z Yes if No ft Wells on Adjacent Lots: if No ft Private Wells > 100' if No ft ** if No ft Community Wells > 200' ❑ Yes if No [—]Yes if No If tank or field is under driveway comment below F. ENGINEER'S COMMENTS *MET CODE AT TIME OF INSTALL **ASSUMED BASED ON WATER KEY LOCATION ST1 IS APPROXIMATLEY 2' FROM DRIVEWAY ft ft ft ft ft ft ft ft G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Garness Engineering Group, LTD. (GEG) Phone 907-337J-6179 Engineer's Printed Name Jeffrey A. Garness Date 31 7.3 In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in i accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the systems on the date/s of the evaluation. O OF q / 0444 Separation distances were measured to readily identifiable features. Hidden defects or encroachments may o C� exist that were not identified during the evaluation. The operational life of all wells and septic systems depend O�P� . (/ . • S �0 upon a variety of variables, including (but not limited to) soil conditions, groundwater levels (that may fluctuate p�-' •.'� Q during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing i0 c L� 9iTH the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not �• • • • • • • • 1.. • • .... guarantee future performance of the systems; therefore, GEG makes no warranty (express or Implied) regarding P / l the future performance of the well or septic system. GEG makes no representation whether an altemative well V .......... • ......� or septic system can be installed on the property in the event either of the current systems fail to perform Q' Jf A. Garness_)- G adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG 01 B CE—7953 p� to perform the evaluation. Reliance upon the information provided in this report by any other person or party Q s ,c�O (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. 04FP e Foo LICENSE 440aProf essio� o� COSA Checklist June 2022 #AECC884 04000 00 Od GARNESS ENGINEERING GROUP, Ltd AeroCell • ENGINEERING SALES > CONSULTING Aresrr.2 Awhar+zed Denlor March 30th, 2023 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Tank Baffle at Sky Ranch Estates #2; Block 2, Lot 22 To whom it may concern: Per ARM Septic services camera inspection, the outlet bung on the septic tank is horizontal (not vertical). Additionally, per ARM camera inspection, there is a belly in the sewer line prior to the tank. We request that your department allow for the sewer line and bung to remain as is. Justifications for allowing this is as follows: • Per the owner (email attached), clogging is a rare occurrence of the septic system (once every two to three years). • The belly has likely existed for the life of the system. • We request that the department issue an advisory notice regarding the belly prior to the septic tank. If the buyer is uncomfortable with the deficiency, they may resolve it at a later date. • Per Ted Moore, PE inspection report, the concrete septic tank is 3 compartments. • It is plausible that an additional compartment could increase the amount of grease and/or sludge removal. A baffle opening is typically in the midline of tank, which is intended to limit sludge and or grease/scum from entering the other side of the baffle (by drawing from mid -depth). • Per ARM Septic services camera inspection, the baffles appear to be in "good condition" • The drainfields have existed for a significant period of time (1993 and 1976). Given the age of the drainfields, the bung configuration does not appear to have negatively impact the longevity of the drainfield. We feel there is minimal risk in allowing the system to remain as is. If you have any questions, please contact us at 337-6179. Thank you for your assistance. Sincerely, / A JeffreX' Qarndst P.E., M.S. Presi ent 3701 East Tudor Road, Suite 101 *Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Website: www.garnessengineering.com David Garness From: Jeff Rognes <jeffrognes@aol.com> Sent: Tuesday, March 21, 2023 8:45 PM To: David Garness Subject: Re: Sky Ranch Estates #2; Block 2, Lot 22 David, We have had the occasional blocked line when someone(usually a guest) has used too much toilet paper. It has happened maybe once every two or three years. Jeff Sent from my iPhone On Mar 21, 2023, at 4:42 PM, David Garness <David@garnessengineering.com> wrote: Jeff, Per the inspection report by ARM services, there is a belly in the line before the concrete tank. I was wondering if you have had any issues with clogging of the sewer line prior to the tank. Sincerely, David Garness, P.E., M.S. Civil Engineer Garness Engineering Group, Ltd. 3701 E. Tudor Road, Suite 101 Anchorage, Alaska 99507 Phone: (907) 337-6179 Mobile: (907) 632-4528 Website: www.garnessengineering.com <image008.png> <image009.jpg> <image005. jpg> <image010Jpg> David Garness From: ARM Septic Services, LLC <armservicesak@outlook.com>" Sent: Friday, March 17, 2023 1:16 PM To: David Garness Subject: Re: 11721 'Shetland Heights Circle Tank inspection " Helo, It should also be noted that an approximately 8' long belly exists right before the tank. Not sure if you need that info for the COSA or not. Let me know if you have any questions. Thanks! Nathaniel Swanberg Septic Technician ARM Septic Services, LLC Ph: (907) 688-9433 Cell: (907) 854-1684 Email: ARMServicesAK@outlook.com Pers: swanberg.n_armservices@outlook.com Website: www.ARMServicesAK.com Facebook: www.facebook.com/ARMServicesAK/ On Mar 17, 2023, at 1:09 PM, ARM Septic Services LLC <armservicesak@outlook.com> wrote: Hello David, Please see the attached files regarding our recent inspection at the subject property. The video is from the inlet side of the tank, and the photo is from the outlet side. Baffles appeared to be in god condition and not damaged, but I'm not sure what to make of the outlet baffle T being horizontal. I'll have to defer to you on the legality of that. Center baffle of the tank appeared to be made of concrete and in good condition. The cleanout just upstream of the tank that was broken at/below grade was repaired and extended above grade. Let me know if you have any questions. Thanks! Nathaniel Swanberg Septic Technician ARM Septic Services, LLC Ph: (907) 688-9433 Cell: (907) 854-1684 Email: ARMServicesAK@outlook.com David Garness From: David Garness Sent: Friday, March 17, 2023 4:00 PM To: 'Wockenfuss, Deborah M.' Cc: Jeff Garness Subject: FW: 11721 Shetland Heights Circle Tank inspection Attachments: 11721 Shetland Heights Tank inspection 5.mov Deb, Below is an email from ARM Septic Servcies. As can be seen below, the baffle is "good condition", however, the outlet bung is horizontal (not vertical), In theory, this would allow grease and/or solids to enter the drainfield. However, the drainfield has been in use for a significant period of time and is still functioning. In short, although the outlet baffle positioning is not ideal, it does not appear to have significantly reducing the life of the drainfield/s. In short, we are requesting that your department allow the outlet bung to remain "as is". Please let me know if you have any questions. Thank you Sincerely, David Garness, P.E., M.S. Civil Engineer Garness Engineering Group, Ltd. 3701 E. Tudor Road, Suite 101 Anchorage, Alaska 99507 Phone: (907) 337-6179 Mobile: (907) 632-4528 Website: www.aarnesseneineerine.com From: ARM Septic Services LLC <armservicesak@outlook.com> Sent: Friday, March 17, 2023 1:09 PM To: David Garness <David@garnessengineering.com> Subject: 11721 Shetland Heights Circle Tank inspection Hello David, Please see the attached files regarding our recent inspection at the subject property. The video is from the inlet side of the tank, and the photo is from the outlet side. Baffles appeared to be in god condition and not damaged, but I'm not MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES_ Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage,'Aiaska 99519-6650 343-4744 ParCel I.D. # - CERTIFICATE OF HEALTH AUTHORITY APPROVAL. FOR A SINGLE FAMILY DWELLING ,"~o~-- L'J/O HAA#_ GENERAL INFORMATION Complete legal description . Location (site address or directions) Property owner ~{;.[-,L,~ ~,~;,,~,- ~-;u,'~) '~"~-~-~,'[' _ Day phone Mailing address ~, O. ~,~. ;Z $Co'-~ cl o Lending agency Day phone Mailing ·address- Agent Day phone Address Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: '~ NOTE: TYPE OF WATER SUPPLY: Individual well Community well Public water . If community well system, provide written confirmation from State ADEC attebt- lng to tile legality and status of system. ~: ~ ' ,., , TYPE OF WASTEWATER DISPOSAL: '. Individual on-site NOTE: Holding tank Community on-site Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. ~ ~ .. 72-025(Rev, I/91) Front MOA#21 5. STATEMENT OF INSPECTION BY 'ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance .with all Municipal and State codes, ordinances, and regulations in effectpn the date of this inspection. Address ~o 5 ~ t~-J--% # ~0._% Engineer's Sign';ture "~-~'- ~ Date Y~-/¢.~" / 6. DI~HS SIGNATURE ' ::X Approved for "~ bedrooms. __ Disapproved. __ Conditional approval for .bedrooms, with the following stipulations: Additional Comments The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the profesaional engineer's work. Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: A. Well Data Well type ¢/~_ i~ Log present (Y/N) Total depth Sanitary seal (Y/N) If A, B, or C, attach ADEC letter. ADEC water system number Date completed Driller Cased to Casing height Wires properly protected (Y/N) FROM WELL LOG Date of test Static water level Well flow Pump level1 SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot Absorption field on lot Public sewer main g.p,m. AT INSPECTION g.p.m. ; On adjacent lots ; On adjacent lots Public sewer manhole/cleanout Sewer service fine Petroleum tank WATER SAMPLE RESULTS: Coliform Nitrate Other bacteria Date of sample: Collected by: B. Sr-'PTIC/HOLDING TANK DATA Date installed ~7/0 ~/ /'-Y ~ Tank size /~2~.~,~ Compartments Cleanouts (Y/N) '-,/ Foundation cleanout (Y/N) ',/ Depression (Y/N) High water alarm (Y/4 h,¢//,~ Aa~rm tested (Y/N) Date of pumping ~°~/,5~ / '~ LI Pumper ,/~ ''~- SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot ?"//~,, On adjacent lots /~'J,,~ Foundation To properly line ¢~- '~ Absorption field ~ Water main/service line Surface water/drainage ~/O 72-026 (3/93)* Frol~t CONTINUED ON BACK PAGE C. LIFT STATION Date installed Manufacturer Size in gallons Vent (Y/N) "Pump on" level at Manhole/Access (Y/N) "Pump off" Level at High water alarm level Cycles tested Meets MOA electrical codes (Y/N) SEPARATION DISTANCE FROM LIFT STATION TO: Well on lot On adjacent lots Surface water D. ABSORPTION FIELD DATA Date installed 7//~/ Length q7¢'/~= ~_5 ~ Width Total absorption area Date of adequacy test Water level in absorption field before test Peroxide treatment (past 12 months) (Y/N) Soil rating (GPD/Ft2) ~, /~¢ System type Gravel thickness ,~ Total depth Cleanout present (Y/N) "j Depression over field (Y/N) Results (pass/fail) ~'~ far If yes, give date Bedrooms SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot /'~//,,~- To building foundation On adjacent lots ;> Surface water Curtain drain On adjacent lots /"¢/¢A Property line To existing or abandoned system on lot Cutbank /'1/~ ~-~ ~ Water main/service line Driveway, parking/vehicle storage area E, ENGINEER'S CERTIFICATION I certify that I have checked, verified, or conformed to afl MOA and HAA guidelines Signature Engineer's Name Date HAA Fee $ ~-~(~ ~ / ~ Date of Payment ¢~ ¢¢~-~, -- ~'15' Receipt Number ¢~)/~-- f"~ ~'~'-'-~ ,/ 72-026 (3/93)* Back Waiver Fee $ Date of Payment Receipt Number in effect c this inspection. .... DA'T E ~-~'C E I V E D · INSi~ECTION APPOINTMENTS TIME TIME TIME SPEOTOR INSPEOTOR INS.EOTO¢ MUNIC PAL TY OF ANCHORAGE  DEPARTMENT OF HEALTH & ENVIRONMENTAL PRO~I'ITY OF ANCHORAGE ENVIRONMENTAL SANITATION DIVISION Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND DI REGTIONS: Complete all parts on page 1, Incomplete requests will not be processed, Please allow ten (10) days for processing. ~ PROPERTY OWNER PHONE ~AI LING ADDRESS PR OP E~f~EN; ~,~nt fra~ ~;( PHONE ~AI LING ADDRESS ~1 LING ADDRESS REALTOR/AGENT ~. LEGAL DESCRIPTION STREET LOCATION 5, TYPE OF RESIDENCE NUMBER OF~BEDROOMS [] One [] Four ""~ SINGLE FAMILY [] Two I-] Five [] MULTIPLE FAMILY ~. Three FI Six Other 7, WATER SUPPLY [] INDIVI DUAL* * ATTACH WELL LOG. A well Io§ is required for all wells drilled ,::l~ COMMUNITY since June 1975. For wells drilled prior to that date, give well [] PUBLIC UTILITY depth (attach log if. available.) 8. SEWAGE DISPOSAL SYSTEM '~ ~, INDIVIDUAL/ON-SITE** "///J~'~- 7~YEAR ON-SITE SYSTEM WAS INSTALLED. [] PUBLIC UTI LITe' NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCE,)$1NG CAN BE INITIATED. THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2, WATER SUPPLY [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3, SEWAGE DISPOSAL SYSTEM PERMIT NUMBER []INDIVIDUAL/ON -8lTL DATE INSTALLED []PUBLIC UTILITY Connection Verified iNSTALLER [~SepticTank or E~]Holding Tank Size: /~-..~'~ If Tank is homemade SOILS RATING TOTAL ABSORPTION AREA MATERIAL 4, DISTANCESwELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line ' 5, COMMENTS PP.OVEDFO. BED.OOMS [] CONDITIONAL APPROVAL {letter mu party certificate) 72-010 (Rev, 6/79)