Loading...
HomeMy WebLinkAboutSKY RANCH ESTATES #2 BLK 3 LT 3 MUNICIPALITY OF ANCHORAGE DE. tTMENT OF HEALTH AND HUMAN SER', ES Environmental Health Division .-~ ~ /~ 825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720 ~ / .b ON-SlI'E SFWAGE DISPOSAL SYSTEM AND/OR WELl_ INSPECTION REPORT Nsme LEGAL DESCRIPTION TANKS ~ SEPTIC/~./P/~ )'Tt~ ~ HOLDING TYPE OF SYSTEM TRENCH '.~ BED ~ W. DRAIN ~ OTHER DISTANCES ~ T[ SEPTIC Al]SORPTION FROM ~ TANK FIELD WELL WELL (,',P~?'? , /~¥',? /.)'1 ~ LOT LINE /~) ,/ i0 ....... ~FOUNI]ATION ~ !? ' ~'" or,glna, grade /,~" "' -¢,%' F'[ .~". / FT WELLS PRIVATE t~' OTHER (Identify) fola~ Depth ET Cased to FT Ins,p~ctions Pedormed y: ,,%/ ENGINEER'S SEAL Muuicipal and Sta~e guidelines ill ellect oe this date: H eallh D epart.,en, Apl)royal: .~~~,- 72 013 (3~85) INSPECTION REPORT MUNICIPALITY OF ANCHORAGE, BUILDING SAFETY DIVISION 3500 EAST TUDOR ROAD INSPECTIONS (907) 563-3464 ADMINISTRATION (907) 786-8301 F00:I'ING' :__ [] ELEC. TEMP. " [] PLBG, UNDGR,___ [] FOUNBATION __-- [] ELEC. SERVICE ___ [] PLBG, ROUGH_ [] BOND BEAM ____ [] ELEC. ROUGH ____ ~t~ GAS'rEMP. __ [] FRAMING .-- [] ELEC. FINAL '[~ GAS [] INSULATION ~ [] 'OTHER [] MECHANICAL ___ [] · I SHEETR?/CK"-- [] MECH. FINAL ---- [] STRUC~FINAL __ [] FIRE FINAL [] PLBG. FINAL .__ [] OTH,,.ER , [] ZONING [] OTHER . [] [~/~O NONCOMPLIANCE OBSERVED [] WILL REEXAMINE AT NI-'XT INSPECTION COMMENTS [] CORRECTIONS ESSENTIAL AS EXPLAINED BELOW ~] DO NOT CONCEAL UNTIL REINSPECTED WHEN cORRECTIONS ARE MADE, PLEASE CALL FOR INSPECTION. DO NOT REMOVE THIS NOTICE MUNICIPALITY OF ANCHORAGE Department ' Health and Environmenta-~ rotection Pouch 6-650, Anchorage, AK 99502 264- 4744 On-site Sewer~r~ Permit HANDWRITTEN Permit No: - Lot: ~_~ Block:'~ Date Issued: Lot Size: ) Lot Location: Township: or Acres) Range: Max Bedrooms: Listed below are the options available to you in designing your septic system. Choose the option that best fits your site. TRENCH BED -~-- W. DRAIN Depth to pipe bottom(ft.) /' fi' Gravel depth (ft.) ~O, ff Total depth (ft.) ~,~ / Gravel width (ft.) ~'0,~, Gravel length (ft.) ~'j /// . Tank size (gal.) ~9~1~¥~71~~ .... Soil rating (sq. ft./br) ~p~ ' ** Gravel length 75 feet requires multiple runs (not exceeding 75 feet each) ~% Tank ~ms± ~ave at least t~.o compartments I certify that: 1. I ant familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage(MOA) and the State of Alaska. 2. I will install the system in accordance with all MOA codes and regulations, and in compliance with the design criteria of this permit. 3. I will adhere to all MOA and State of Alaska requirements for the set back distances from any existing well, wastewater disposal system or public sewerage system on this or any adjacent or nearby lot. 4. I understand that this permit is valid for the maximum number of bedrooms. stated above, and any enlargement or modification will require an additional permit. IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES, THEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS-BUILTS WILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT; AND (3) THE ELECTRICAL WORK MUST BE DONE BY A LICENSED ELECTRICIAN. o SWP/024 rev.1/85 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: ~,'r' ~ .~z',~,~.~ ~/f.~-R/~ ,~.~. Township, Range, Section: 1 2 3 4 5 6- 7 8- 9- 10- 11 13 14 15 16 17 18 19 20 SLOPE WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT - DEl)TH? pO E Depth la Water After Monitoring? SITE PLAN A \ Gross Net Depth to Net Reading Date Time Time Water Drop _ PERCOLATION RATE __ {m,nutes/inch) PERC HOLE DIAMETER __ TEST RUN BETWEEN FT AND -- FT PERFORMED BY: ~;'~ ~ /~-. ~'~/~;7'/I/' I ~ CERTIFY THAT THIS 'rEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) , I UNIFIED SYSTEM ASTM D-2487 SKYRANCN I~B3 SAMPLE IDENTITY CENTER PASSING #200 SIEVE: 7.00% RETAINED: PASSING # 40 SIEVE: 25.70% RETAINED: PASSING # 10 SIEVE: 49.10% KETAINED: PASSING # 4 SIEVE: 63.20% EETAINED: PASSING 1/2 IN SIEVE: 78.90% RETAINED: PASSING 3/4 IN SIEVE: 87.50% RETAINED: PASSING I INCH SIEVE: 100.00% RETAINED: PASSING 2 INCH SIEVE: 100.00% RETAINED: PASSING 3 INCH SIEVE: 100.00% RETAINED: D]O IS 0.15 MM. D30 IS 0.60 b~l. D60 IS 4.50 }~i. TRE LIQUID LIMIT IS UNKNOWN Tile PLASTIC LIMIT IS UNKNOWN THE PLASTICITY INDEX IS UNKNOWN CU = 30.00 CC = 0.533 18.70% 23.40% 14.10% 15.70% 8.60% 12.50% 0.00% 0.00% 0.00% THE SOILS ARE COARSE GRAINED SANDY SOILS BORDERLINE SOILS THE SOILS ARE POORLY GRADED SAND.(SP) ALASKA ' ' UIROnBCnTAL COI TROL S "ICeS, IBC Legal Description Sample Depth. D lO,"~ ,15 D 30% , ~ D 60% ~.~ ,$ Comments 'rE~ HOLE NO. ~ ~7~-x~ Date Reported to Plotted . ~((~,'~_Cheeked by. ~pproved by_ ~ ~ S,EVE ^NAL¥S,S SIZE OF OPENING iN INCHES J NUMBER OF MESH PER INCH U.S. STANDARD ~ ~ll~l -~o I~'" - ~ ~o: ~ ~ -4o ~40 x ,60 ~ - GRAIN SiZE IN MILLIMETERS COBB~S L SANO 1200 [Ucsl 33r~J At~¢nu¢. SulJ~ B. An[~oro(F Alos~e 99,503.(907) 561.5040 SKYP, ANCH L,~B3 TE8THOLE - CENTER SAMPLE DEPTIt =--~Z/ PERCENT PASSING #200 SIEVE 7.0 PERCENT PASSING #100 SIEVE ]1.3 PERCENT PASSING # 6{) SIEVE 17.5 PERCENT PASSING # 40 SIEVE 25.7 PERCENT FASSING # 20 SIEVE 35.2 PERCENT PASSING # 10 SIEVE 49.1 PERCENT PASSING # 4 SIEVE 63.2 78.9 87.5 PERCENT PASSING 1/2 IN SIEVE PERCENT PASSING 3/4 IN SIEVE PERCENT PASSING 1 INCH SIEVE 100.0 PERCENT PASSING 2 INCH SIEVE 100.0 PERCENT PAS~ING 3 INCH SIEVE 100.0 GRE '"ER ANCHORAGI! AREA BOROUGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAl. SYSTEM LOCATION MAILING ADDRESS ~/~/¢ /~hg/ LEGAL DESCRIPTION SEPTIC TANK: DISTANCE t/v/ FROM ~-- /0 MANUFACTURER ~'~-,,¢tl~ MATERIAL NUMBER OF COMPARTMENTS INSIDE LENGTH INSIDE WIDTH . __LIQUID DEPTH __ LIQUID CAPACITY t/¢F'~-~ GALLONS. SEEPAGE PIT: NUMBER OF PITS / DIAMETER ____OR WIDTH LENGTH DEPTH /~1 LIN lNG MA-FE R IAL/~/~$¢pf_~C RI B SIZ E: DIAMETER___DEPTH ~ 1. DISTANCE FROM: BUILDING POUNDATION ~'/~ NEAREST LOT LINE ~¢~ TOTAL EFFECTIVE WE4:L /0 ABSORPTION AREA (WALL AREA) J~t/~ SQ. FT. ADDITIONAL ABSORPTION TYPE ~/f-L /8 /._ ~ ~.~ CONSTRUCTION DEPTH BUILDING NEAREST NEAREST SEPTIC FOUNDATION LOT LINE SEWER LINE TANK CESSPOOL APPROVED OTHER SOURCES /_ DISAPPROVED REMARKS. DISTANCE FROM: SEEPAGE SYSTEM DISTANCES: INSTAl_LED BY: PIPE MATERIAL: LOT SLOPE: REMARKS: Form No. EQ-031 DATE DIAGRAM OF SYSTEM Io/" k APPROVED, ' ~-- G,A,A,B, SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT GREATER ANCHORAGE AREA BOROUGH NAME OF APPLICANT MAILING PHONE ~--~ INSTALLATION LOCATION J/c~/.~.~ ~:~ ~/~ FINANCED TH"OUOH .... TO BE INSTALLED bY ~~ ~ ' SEPtiC TANK~.~ / , seEPAGE PIT~ __, DRAIN WELL TO SEPTIC TANK DRAIN FIELD WATER main TO SEPTIC tANK SEPTIC TANK, /~-~--, SEEPAGE SEEPAGE PIT ALSO CONSIDER AREA WELLS, , SEEPAGE Pit DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSS~NG GAP OF FORM NO, EQ'0$ 6 Performed For d~rbe-I~r~, ~C~-~?'ra?~ Date Per'~or?ed Was ~omd,- Water tlncounterecl?. Yes, At ~.~hat 3enth? -2: ' /2/ ~o ~g'.~'.g ",kk/ -, /~ O0 ol XtOT'Z:'/' I ] "' :" ' "' 'it ,s the COnh'actor's responsibilib] Top of Foundation in relationship to.Finish. ..'dr!~de' Top of Foundation as indicit~I .... m'~e of bl6ck abov~ 'Finis4: Ora~ I hereby certify that I have s~eyed the following described property: ~ ~ ~ ,(~ ~. Anchorage 13ecordhig Precinct, Alaska, and that the improvern~fits situated thereon a~e within the prope~y lines and do not overlap or encroach on the property lying adjacent thereto, that no improvemen~ on prop- erty lying adjacent thereto encroach on the premises m 2uestion and that there ~e no roadways, transmission hues or other visible ensemen~ on ~atd property except a~ ~dicated hereon. Dated at ~chorage, Al~ka ~ED WA~ & ASSOCIA~S Engineers ~d S~veyo~